ML070160124

From kanterella
Revision as of 04:19, 15 January 2025 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
YNPS-FSS-OOL-03-00, Appendix D, Generic ALARA Evaluation Comparison Worksheet
ML070160124
Person / Time
Site: Yankee Rowe
Issue date: 11/09/2005
From:
Yankee Atomic Electric Co
To:
NRC/FSME
References
OOL-03, YA-REPT-00-003-05 YNPS-FSS-OOL-03-00
Download: ML070160124 (3)


Text

Generic ALARA Evaluation Comparison Worksheet

/ Survey Area: 00L - 0 3 Survey Unit: 0 1 I Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05

) Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL C(fraction DCGL) =

0 0 6 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

FSS Project Manager DPF-8867.1 Rev. 2 Page 1 of 1

Generic ALARA Evaluation Comparison Worksheet

-~~

Survey Area:

OOL-03 Survey Unit:

02 Reference Generic AURA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

CO-60 0.238 1.4 1.70E-01 2

CS-137 0.805 3

2.68E-01 3

4 C(fraction DCGL):

4.38E-01 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Ron Shippee Date:

8/7/2006 FSS Radiological Engineer/

Reviewed by:

r k f l Date:

nagdRadiation m c t i o n Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-03 Survey Un~t:

03 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

Co-60 0.0102 1.4 7.29E-03 2

CS-137 0.1204 3

4.01E-02 3

4 C(fraction DCGL):

4.74E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Ron Shippee Date:

8/10/2006 FSS Radiological Engineed

/ I Reviewed by:

d Date:

~ r i $ i i a ~ h ~ d g Protection Manager