Jump to navigation Jump to search
Notifies That Use of ASME Code Case N-411, Alternative Damping Values for Seismic Analysis of Piping Sections..., in Lieu of Reg Guide 1.61 Values Approved for Spectrum Seismic Analysis of Piping,Per 841011 & 850212 Requests
ML17055A827
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 11/22/1985
From: Harold Denton
Office of Nuclear Reactor Regulation
To: Hooten B
NIAGARA MOHAWK POWER CORP.
References
RTR-REGGD-01.061, RTR-REGGD-1.061 NUDOCS 8512040173
Download: ML17055A827 (8)


Text

~.

gp,g RECgp (4

0~i OO

,gu

~O

++*++

Docket No. 50-410

~ 0 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NOV 2 g ISU6 Mr. B. G. Hooten Executive Director of I'luclear Operations Niagara Mohawk Power Corporation 300 Erie Boulevard I<est

Syracuse, NY 13202

Dear Mr. Hooten:

SUBJECT:

USE OF ASME CODE CASE N-411 FOR NINE MILE POINT UNIT 2

Reference:

1.

Letter from C.V. Mangan, Niagara Mohawk Power Corp., to A. Schwencer, NRC, dated October 11, 1984 2.

Letter from C.V. Mangan to A. Schwencer, dated February 12, 1985 In References 1 and 2, Niagara Ilohawk requested NRC approval to use ASME Code Case I'I-411, "Alternative Damping Values for Seismic Analysis of Piping Section III, Division 1, Class 1, 2, and 3 Construction," in the damping spectrum seismic analysis of piping for Nine Mile Point, Unit 2.

In Mr. Mangan's letters, he stated that these damping criteria will be used an an alternative to the values given in Regulatory Guide 1.61, "Damping Values for Seismic Design of Nuclear Power Plants."

In addition, he stated that they will only be used when necessary to resolve design or as-built verification items and that, when used, the new criteria will be applied in their entirety to both the operating basis earthquake and safe shutdown earthquake analysis.

The expected increased piping displacements resulting from using damping values in ASME Code Case N-411 will be verified when piping supports are moved, modified or eliminated.

The verification will ensure that there will be no adverse interaction with adjacent structures, components, and equipment.

The above commitments will be incor-porated into the Final Safety Analysis Report.

Code Case N-411 is a conditionally acceptable Code Case and has been approved by the staff for specific plant applications.

The above commitments from the applicant are sufficient to satisfy the conditions which the staff has placed on this Code Case.

Therefore, the staff finds Niagara Mohawk's proposed use of Code Case N-411 to be acceptable for use at Nine Mile Point, Unit 2 in the response spectrum seismic analysis of piping.

8512040173, 851 122 PDR

  • DOCK'5000410 A

'DR

~ 0

~y L

)e F

Any questions concerning the above evaluation of the proposed use of Code Case N-411 for Nine Nile Point, Unit 2 should be directed to the Licensing Project

Hanager, Nary Haughey, (301) 492-7897.

Sincerely, Harold R. Denton, Director Office of Nuclear Reactor Regulation cc:

See next page

4

V

~

R R

ee Any questions concerning the above evaluation of the proposed use of Code Case N-411 for Nine tlile Point, Unit 2 should be directed to the Licensing Project

Manager, teary Haughey, (301) 492-7897.

Sincerely, a(lgjnal Qgg55 LL~.

Harold R. Denton, Director Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION NRC PDR Local PDR PRC System t<SIC LB¹2 Reading EHylton NHaughey Bordenick, OELD JPartlow BGrimes EJordan RLi, DE RKirkwood, DE LB¹2 DL PH tlHaughey:lb 10/gg/85 D/

HD ton g/P/85 LB¹2/D /BC WButler IO/>8/85 D/L/DL~

TtlNovak 10/3 )/85 Ftl gl ia 10+ /85 D/ L DD R

HThompson D

ut

$(/ 1 /85 1

/85

b'

Mr. B. G. Hooten Niagara Mohawk.Power Corporation Nine Mile Point Nuclear Station Unit 2 CC:

Mr. Troy B. Conner, Jr.,

Esq.

Conner 8 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.W.

Washington, D.C.

20006 Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus

Syracuse, New York 12223 Ezra I. Bialik Assistant Attorney General Environmental Protection Bureau New York State Department of Law 2 World Trade Center New York, New York 10047 Resident Inspector Nine Mile Point Nuclear Power Station P. 0.

Box 99

Lycoming, New York 13093 Mr. John W. Keib, Esq.

Niagara Mohawk Power Corporation 300 Erie Boulevard West

Syracuse, New York 13202 Mr. James Linville U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Norman Rademacher, Licensing Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Regional Admini s trator, Region I

U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Paul D.

Eddy New York State Public Service Coomission Nine Viile Point Nuclear Station-Unit II Post Office Box 63

Lycoming, New York 13093

~ w' t

~