Quad-Cities Units 1, Tech Spec 2.0 Safety Limits for Amendment No. 207
ML022120589
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 07/29/2002
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML022120589 (1)


Text

SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:

THERMAL POWER shall be ! 25% RTP.

2.1.1.2 With the reactor steam dome pressure Ž 785 psig and core flow Ž 10% rated core flow:

For Unit 1, with Cycle 17A exposure less than or equal to 4,000 MWD/MT, for two recirculation loop operation, MCPR sha'l be ? 1.11, or for single recirculation loop operation, MCPR shall be Ž 1.12. For Unit 1, with Cycle 17A exposure greater than 4,000 MWD/MTU, for two recirculation loop operation MCPR shall be > 1.15, or for single recirculation loop operation MCPR shall be > 1.16.

For Unit 2, MCPR shall be Ž 1.11 for two recirulation loop operation, or for single recirculation loop operation, MCPR shall be ? 1.12.

2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 5 1345 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.

Quad Cities 1 and 2 2.0-1 Amendment No. 207/202