3.7 PLANT SYSTEMS 3.7.4 Control Room Emergency Ventilation (CREV) System LCO 3.7.4 The CREV System shall be OPERABLE.

APPLICABILITY :

ACTIONS REQUIRED ACTION Restore CREV System to OPERABLE status.

AND B.2 AND B.3 Initiate action to implement mitigating actions.

Verify mitigating actions ensure CRE occupant exposures to radiological, chemical, and smoke hazards will not exceed limits.

Restore CRE boundary to OPERABLE status.

CONDITION A.

CREV System inoperable in MODE l, 2, or 3 for reasons other than Condition B.

B.

CREV system inoperable due to inoperable CRE boundary in MODE 1, 2, or 3.

Dresden 2 and 3


NOTE---------------

The main control room envelope (CRE) boundary may be opened intermittently under administrative control MODES 1, 2, and 3, During movement of recently irradiated fuel assemblies in the secondary containment, During operations with a potential for draining the reactor vessel (OPDRVs) 3.7.4-1 COMPLETION TIME 7 days Immediately 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 90 days CREV System 3.7.4 (continued)

Amendment No.

ACTIONS (continued)

Dresden 2 and 3 3.7.4-2 CREV System 3.7.4 Amendment No.

C.

Required Action and associated Completion Time of Condition A or B not met in MODE 1, 2, or 3.

C.1 Be in MODE 3.

AND C.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 36 hours D.

CREV System inoperable


NOTE ----__---__--

during movement of LCO 3.0.3 is not applicable.

recently irradiated fuel assemblies in the secondary containment D.1 Suspend movement of Immediately or during OPDRVs recently irradiated fuel assemblies in OR the secondary containment.

CREV System inoperable due to an inoperable AND CRE boundary during movement of recently D.2 Initiate action to Immediately irradiated fuel suspend OPDRVs.

assemblies in the secondary containment or during OPDRVs.

SURVEILLANCE REQUIREMENTS CREV System 3.7.4 Dresden 2 and 3 3.7.4-3 Amendment No.

SURVEILLANCE FREQUENCY SR 3.7.4.1 Operate the CREV System for >_ 10 continuous 31 days hours with the heaters operating.

SR 3.7.4.2 Perform required CREV filter testing in In accordance accordance with the Ventilation Filter with the VFTP Testing Program (VFTP).

SR 3.7.4.3 Verify the CREV System actuates on a manual 24 months initiation signal SR 3.7.4.4 Perform required CRE unfiltered air In accordance inleakage testing in accordance with the with the Control Room Envelope Habitability Program.

Control Room Envelope Habitability Program