._

Arkansas Nuclear One - Administrative Services Document Control Tuesday, June 03, 2003 Document Update Notification COPYHOLDER NO: 103 TO: ANO-NRC (EMERGENCY RESPONSE COORD.) - WASHINGTON ADDRESS. OS-DOC CNTRL DESK MAIL STOP OPl-17 WASHINGTON DC 20555-DC DOCUMENTNO: OP-1905.004 TITLE. EOF RADIOLOGICAL CONTROLS CHANGE NO: 007-01-0 ADDITIONAL INFO:

F (-. If this box is checked, please sign, date, and return within S days.

O] ANO-1 Docket 50-313 Ti GANO-2 Docket 50-368 Signaue Date SIGNATURE CONFIRMS UPDATE HAS BEEN MADE RETURN TO:

ATTN: DOCUMENT CONTROL-(N-ADMIN-24)

ARKANSAS NUCLEAR ONE 1448 SR 333 RUSSELLVILLE, AR 72801 V~

I ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE TITLE: EOF RADIOLOGICAL CONTROLS DOCUMENT NO. CHANGE NO.

1905.004 007-01-0 WORK PLAN EXP. DATE TC EXP. DATE SET # /°5 3SAFETY-RELATED §YES ONO IPTE DYES ONO TEMP ALT OYES ONO When you see these TRAPS Get these TOOLS lime Pressure Effective Communication Distraction/interruption Questioning Attitude Multiple Tasks Placekeeping Overconfidence Self Check Vague or Interpretive Guidance Peer Check First Shift/Last Shift Knowledge Peer Pressure Procedures Change/Off Normal Job Briefing

- Pkhvcipr-nvirnnmjnt

  • . v rnEh%a wv***

hi" .

Mental Stress (Home or Work) Tumover VERIFIED BY l DATE I TIME FORM TITLE: FORM NO. CHANGENO.

I j VERIFICATION COVER SHEET I 1000.006A 050-00-0

ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE Page 1 TITLE:EOF RADIOLOGICAL CONTROLS DOCUMENT NO. CHANGE %

1905.004 007= 1-AFFECTED UNIT: PROCEDURE O ELECTRONIC DOCUMENT SAFETY-RELATED 0 UNIT 1 0 UNIT2 [ ] WORK PLAN, EXP. DATE 03 YES El NO TYPE OF CHANGE:

El NEW C PC D TC D DELETION o REVISION 0D EZ EXP. DATE:_

DOES THIS DOCUMENT:

1. Supersede or replace another procedure? D YES ONO (If YES, complete 1000.006 for deleted procedure.) (OCAN058107)
2. Alter or delete an existing regulatory commitment? DYES ONO (If YES, coordinate with Ucensing before implementing.) (CNA128509)(0CAN049803)
3. Require a 50.59 review per U-101? (See also 1000.006, Attachment 15) 0 YES 0 NO (If 50.59 evaluation, OSRC review required.)
4. Cause the MTCL to be untrue? (See Step 8.5 for details.) OYES ONO (If YES, complete 1000.009A) (1CAN108904, 0CAN099001, OCNA128509, OCAN049803)
5. Create an Intent Change? DYES ONO (If YES, Standard Approval Process required.)
6. Implement or change IPTE requirements? DYES ONO (If YES, complete 1000.143A OSRC review required.)
7. Implement or change a Temporary Alteration? 0 YES ONO (If YES, then OSRC review required.)

Was the Master Electronic File used as the source document? 0 YES 0 NO INTERIM APPROVAL PROCESS STANDARD APPROVAL PROCESS ORIGINATOR SIGNATURE: (Includes review of Att. 13) DATE: ORIGINATOR SIGNATURE: (Includes review of Att. 13) DATE: z743 Print and tn name: Print and Sign name: o4%- 1d 4 . PHONE9: ' >

SUPERVISOR APPROVAL:

  • DATE: INDEPEET REVIEWER: DAT,1:

SRO UNIT ONE : DATE: ENGINEERING: X DATE:

SRO U O DATE: QUALITY: DATE:

Interim approval allowed for non-intent changes requiring no UNIT SURVEILLANCE COORDINATpR (OCNA0498W3): DATE:

50.59 evaluation that are stopping work in progress. ____

Standard Approval required for intent changes or changes S N LEADE/

requiring a 50.59 evaluation. L

'If change not required to support work in progress, QUALITY ASSURANCE: c DATE:

Department Head must sign. _ _ _ _ ___ _ _ _

"If both units are affected by change, both SRO signatures OTHER SECTION LEADERS: DATE:

are required. (SRO signature required for safety related procedures only.) OTHER SECTION LEADERS: DATE:

OTHER SECTION LEADERS: DATE:

OTHER SECTION LEADERS: DATE:

OS CHAIRMAN/TECHNICAL RE\iEWER: (OCNA0493 2)DATE: OTHER SECTION LEADERS: DATE:

mp,§ PROVL Date: OTHER SECTION LEADERS: DATE:

'RQURE EFFECTIVED_ATE:61 REQUIRED EFFECTIVE DATE: 6 ,z /

/_OTHERSECTIONLEADERS:

OTHER

__/

SECTION LEADERS: <g f -DATE:

I I FORM TITL EA PROCEDUREIWORK PLAN APPROVAL REQUEST IFORM NO.

1000.006B CHANGE NO.

051-00-0

ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE TITLE:EOF RADIOLOGICAL CONTROLS OCUMENT NO. CHANGE NO.

1905.004 007-01-0 OPROCEDURE OWORK PLAN, EXP. DATE PAGE_1 OF1 a ELECTRONIC DOCUMENT TYPE OF CHANGE:

a NEW X PC 0 TC 0 DELETION o REVISION 0 EZ EXP. DATE:_

AFFECTED SECTION: DESCRIPTION OF CHANGE: (For each change made, include suffcient detail to describe (Include step # if reason for the change.)

applicable)

Page 2 of 8, step 3.2.6 Changed reference number. Should be RP-105 'Personnel Contamination Events (PCE)'.

Page 2 of 8, step 3.2.8 Deleted step because procedure no longer exist.

Page 2 of 8, step 3.2.11 Changed reference number and title. Should be RP-302 'Operation of Radiation Protection Instrumentation*.

Page 2 section 3 Renumbered steps due to deleting step 3.2.8 No 50.59 Is required as per Attachment 15 of 1000.006.

FORM TITLE: _ FORM NO. CHANGE NO.

DESCRIPTION OF CHANGE 1000.006C 050-00-0

TABLE OF CONTENTS SECTIONS PAGE NO.

1.0 Purpose ............................................................. 2 2.0 Scope ............................................................... 2 3.0 References .......................................................... 2 4.0 Definitions ......................................................... 3 5.0 Responsibilities .. 3 6.0 General Guidelines For EOF Radiological Control .................... 4 7.0 Surveys ............................................................. 4 8.0 Control Points ...................................................... 5 9.0 Attachments And Forms .. 5 9.1 Attachments Attachment 1, "EOF/AEOF Protective Action Guidelines" ...... 6 9.2 Forms Form 1905.004A, "EOF Survey Log" ............................ 8

PROCJWORK PLAN NO. PROCEDURENVORK PLAN MTLE: PAGE: 2 of 8 1905.004 EOF RADIOLOGICAL CONTROLS CHANGE: 007-01-0 1.0 PURPOSE This procedure provides guidance for radiological control practices at the Emergency Operations Facility (EOF) during emergency situations.

2.0 SCOPE 2.1 This procedure is applicable during Alert, Site Area Emergency, or General Emergency conditions.

2.2 This procedure applies to ANO emergency support personnel and the Emergency Operations Facility/Alternate Emergency Operations Facility.

3.0 REFERENCES

3.1 REFERENCES

USED IN PROCEDURE PREPARATION:

3.1.1 Emergency Plan 3.1.2 1000.031, "Radiation Protection Manual" 3.1.3 1903.011, "Emergency Response/Notifications"

3.2 REFERENCES

USED IN CONJUNCTION WITH THIS PROCEDURE:

3.2.1 1903.030, "Evacuation" 3.2.2 1903.034, "Emergency Operations Facility Evacuation" 3.2.3 1903.066, "Emergency Response Facility - Operational Support Center (OSC)"

3.2.4 1903.067, "Emergency Response Facility - Emergency Operations Facility (EOF)"

3.2.5 1012.018, "Administration of Radiological Surveys" 3.2.6 RP-104, "Personnel Contamination Events (PCE)"

3.2.7 1601.200, "Personnel Processing/Records" 3.2.8 1601.208, "Self Reading Dosimeters" 3.2.9 1601.209, "Whole Body Counting/Bioassay" 3.2.10 RP-302, "Operation of Radiation Protection Instrumentation" 3.2.11 1601.443, "Operation of Portable Air Samplers"

PROCJWORK PLAN NO. PROCEDURENVORK PLAN TITLE: PAGE: 3 of 1905.004 EOF RADIOLOGICAL CONTROLS CHANGE: 007-01-0 3.3 RELATED ANO PROCEDURES 1905.001, "Emergency Radiological Controls" 3.4 REGULATORY CORRESPONDENCE CONTAINING NRC COMMITMENTS WHICH ARE IMPLEMENTED IN THIS PROCEDURE:

OCAN038313; Section 8 4.0 DEFINITIONS 4.1 Controlled Access Area - Any area where full radiological controls are in effect for the purpose of providing protection and/or information to the individual. At Arkansas Nuclear One the Controlled Access Area includes the auxiliary buildings inside the turnstyles, both reactor buildings, and inside the fenced area of the BWST/RWT.

4.2 Control Point - The area or location established for the purpose of controlling personnel and/or material movement into and out of a radiologically controlled area.

4.3 Radiologically Controlled Area (RCA) - An area within the plant site in which radioactive material and/or radiation may be present in quantities sufficient to require protective measures. (The Controlled Access Area, for example, is an RCA.)

4.4 Emergency Operations Facility (EOF) - A near site emergency response facility located in the ANO Training Center approximately 0.65 miles northeast of the reactor buildings.

4.5 Alternate Emergency Operations Facility (AEOF) - The Entergy Arkansas Office located at 305 South Knoxville Street, Russellville, or any other facility designated by the EOF Director/TSC Director as appropriate.

5.0 RESPONSIBILITIES 5.1 RADIOLOGICAL/ENVIRONMENTAL ASSESSMENT MANAGER (REAM)

Responsible for the implementation of this procedure during an emergency following arrival at the EOF or Alternate EOF.

5.2 REAM ASSISTANT Responsible for assisting the REAM.

PROCJWORK PLAN NO. PROCEDURENNORK PLAN TITLE: PAGE: 4 of 8 1905.004 EOF RADIOLOGICAL CONTROLS

. CHANGE: 007-01-0 5.3 MANAGER, RADIATION PROTECTION/CHEMISTRY Responsible for the administrative control of this procedure.

5.4 HEALTH PHYSICS SUPERVISOR Responsible for ensuring that HP assistance has been dispatched to the EOF.

5.5 EOF HEALTH PHYSICS SUPERVISOR 5.5.1 Responsible for ensuring that the appropriate control points and radiological control measures are established and implemented at the EOF or AEOF.

5.5.2 Responsible for evaluating radiological conditions of the EOF and recommending EOF protective actions.

5.5.3 Responsible for supervising health physics coverage at the EOF and at the Alternate EOF, if activated.

6.0 GENERAL GUIDELINES FOR EOF RADIOLOGICAL CONTROL 6.1 The EOF HP Supervisor shall determine habitability of EOF and make appropriate recommendations to the REAM in accordance with Attachment 1.

6.2 If the EOF is not habitable, the EOF HP Supervisor shall determine habitability of the AEOF and make appropriate recommendations to the REAM in accordance with Attachment 1.

6.3 Evacuation of the EOF shall be performed in accordance with Procedure 1903.034, "Emergency Operations Facility Evacuation".

7.0 SURVEYS 7.1 Surveys should be conducted in accordance with the applicable radiation protection procedures and emergency radiation protection procedures Series. Performance of surveys should be logged on Form 1905.004A, "EOF Survey Log".

7.2 Survey results shall be performed and documented in accordance with current RP procedures. Radiation surveys should be made inside and outside the EOF hourly and shall be made every two hours.

Contamination surveys should be performed as conditions warrant (i.e.,

contaminated personnel at the control point(s).

7.3 Airborne radioactivity surveys shall be performed and documented in accordance with current RP procedures. If a release is in progress, attempts should be made to take air samples inside and outside the EOF protected area every hour but shall be taken at least every four hours.

PROCJWORK PLAN NO. PROCEDUREIWORK PLAN TITLE: PAGE: 5 of 8 1905.004 EOF RADIOLOGICAL CONTROLS CHANGE: 007-01-0 7.4 A completed copy of each survey report shall be retained by the EOF HP Supervisor.

7.5 The EOF HP Supervisor should provide the REAM a verbal summary report of the EOF radiological conditions at least hourly or more frequently as conditions warrant.

8.0 CONTROL POINTS 8.1 Upon activation of the EOF, radiological control points should be established at the designated exits/entrances to the EOF. (Normally the 1st floor west entrance and the 2nd floor north entrance.)

8.2 The following radiological controls should be instituted at the control points.

8.2.1 A frisking station should be used to check personnel entering the EOF suspected of being contaminated and contamination control points set up accordingly.

NOTE An HP Technician shall be stationed at the control point during plant evacuation to the EOF to monitor Emergency Response/Emergency Standby Personnel as they arrive.

8.2.2 If anyone entering or leaving the EOF is found to be contaminated, decontamination procedures should be evaluated/initiated in accordance with current RP procedures.

9.0 ATTACHMENTS AND FORMS 9.1 ATTACHMENTS Attachment 1, "EOF/AEOF Protective Action Guidelines" 9.2 FORMS Form 1905.004A, "EOF Survey Log"

i PROCJWORK PLAN NO. PROCEDUREVORK PLAN TITLE: PAGE: 6 of 8 1905.004 EOF RADIOLOGICAL CONTROLS CHANGE: 007-01-0 ATTACHMENT 1 Page 1 of 2 EOF/AEOF PROTECTIVE ACTION GUIDELINES CONDITION RECOMMENDED ACTIONS

1. Plant Evacuation declared, EOF Consider relocation of media and/or Evacuation likely to occur. non-essential ANO personnel.
2. Exclusion Area and/or Area Consider protective action for media Evacuation declared. and/or non-essential ANO personnel consistent with the protective action recommendations made for the general public per the applicable EPIP.
3. Area Survey Measurements Exceed Consider evacuation of all non-essential 2.5 mRem/hr in Unprotected personnel from the unprotected areas of Areas of EOF. the EOF.
4. EOF Protected Area Radiation Verify EOF ARM alarm.

Monitor Warning Alarm (1 mr/hr)

Conduct area radiation survey of unprotected areas of EOF and evacuate all personnel in those areas if necessary.

Consider having all ERO personnel, other than activated Emergency Response Teams, to remain sheltered in the protected area of the EOF, unless otherwise instructed by the EOF Director.

5. EOF Protected Area Radiation Verify EOF ARM alarm.

Monitor alarms Hi (2.5 mr/hr) and/or iodine concentration Consider evacuation of all non essential exceeds 2.7E-9 pCi/cc. personnel from the protected areas of the EOF.

All ERO personnel should remain sheltered in the EOF protected area.

Increase frequency of airborne and direct radiation monitoring of EOF, ensure EOF filtered ventilation is operational; record DAC hours.

PROCJWORK PLAN NO. PROCEDUREIWORK PLAN TITLE: PAGE: 7of8 1905.004 EOF RADIOLOGICAL CONTROLS CHANGE: 007-01-0 ATTACHMENT 1 Page 2 of 2 EOF/AEOF PROTECTIVE ACTION GUIDELINES CONDITION RECOMMENDED ACTIONS

6. EOF Protected Area radiation If conditions are estimated to be levels exceed 100 mRem/hr but temporary (less than 30 minutes),

less than 1 Rem/hr, and/or continue on-going protective actions.

iodine concentration exceeds 1 8

DAC(2.OE pCi/cc) .

If conditions are estimated to be long-term (greater than 30 minutes), initiate EOF evacuation.

7. EOF Protected Area radiation Immediate evacuation of the EOF is levels exceed 1 Rem/hr, and/or required.

iodine concentration exceeds 4 DAC (8.0E pCi/cc) .

Page 8 Of 8 Date:_

Contamination J

Highest GA

~~AirJ Sample _

Time Area Levels Dose Rate Clean of Surveyed <1000 dpm in Y/N Badge Inst.

Survey (1) Y/N mRem/hr (2) Surveyed By Number No.

4 4 4- t 4- 4- 4 1 4 -+ 4 + 4- 4 4 4 4- 4 4- 4- 4

& 4 4- 4 4- 4- 4 4 4 4- 4 4- 4 4 4 4- 4 1- 1- 4 4 4 4- 4 4- 4- 4 (1) Area Surveyed - choose from the following:

1) All assigned areas inside and outside 2) All levels inside the EOF
3) Upper level of the EOF 4) Lower level of the EOF
5) All assigned areas outside the EOF
  • (2) Air Sample Clean YN - the air sample can be screened using a frisker as long as the volume of the sample is greater than or equal to 6.OE5cc using the following formula:

(Net cpm)(10)


= Jci/Cc (2.22E6dpm/pCi) (volume)

IF an air sample is not clean by screening with a frisker, THEN notify the EOF HP Supervisor for direction.

IF activity above background is detected (contamination levels or dose rates),

THEN document a survey showing the locations of detected activity and notify the EOF HP supervisor for direction.

Inst. No. Instrument Cal. Due Date Background Reading 1

2 3

4 Reviewed by: Date:

FORM TITLE: l FORM NO. CHANGE l ~~~~~EOF SURVEY LOG I 1905.004A 007 01 0