Letter Sequence Other |
---|
|
|
MONTHYEARML0435005632004-12-29029 December 2004 Y020040251 - F.L. Bonsigniore Ltr. Re. to the Management Staff and Director of Operations of Vermont Yankee Nuclear Plant Project stage: Other 2004-12-29
[Table View] |
|
---|
Category:Letter
MONTHYEARBVY 24-028, Pre-Notice of Disbursement from Decommissioning Trust2024-10-31031 October 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-027, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-10-30030 October 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-026, Pre-Notice of Disbursement from Decommissioning Trust2024-10-0202 October 2024 Pre-Notice of Disbursement from Decommissioning Trust ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status BVY 24-024, Pre-Notice of Disbursement from Decommissioning Trust2024-07-30030 July 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-023, Pre-Notice of Disbursement from Decommissioning Trust2024-07-0202 July 2024 Pre-Notice of Disbursement from Decommissioning Trust IR 05000271/20240012024-06-28028 June 2024 NRC Inspection Report No. 05000271/2024001, Northstar Nuclear Decommissioning Company, LLC, Vermont Yankee Nuclear Power Station, Vernon, Vermont ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities BVY 24-022, Pre-Notice of Disbursement from Decommissioning Trust2024-05-30030 May 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-020, Biennial Update of Quality Assurance Program Manual2024-05-22022 May 2024 Biennial Update of Quality Assurance Program Manual BVY 24-019, 2023 Radiological Environmental Operating Report2024-05-0909 May 2024 2023 Radiological Environmental Operating Report BVY 24-017, Pre-Notice of Disbursement from Decommissioning Trust2024-05-0606 May 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-018, 2023 Radiological Effluent Release Report2024-05-0505 May 2024 2023 Radiological Effluent Release Report BVY 24-016, 2023 Individual Monitoring NRC Form 5 Report2024-04-18018 April 2024 2023 Individual Monitoring NRC Form 5 Report BVY 24-014, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-04-0101 April 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-015, Pre-Notice of Disbursement from Decommissioning Trust2024-04-0101 April 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-012, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-03-14014 March 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-011, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-03-0606 March 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-010, Pre-Notice of Disbursement from Decommissioning Trust2024-03-0505 March 2024 Pre-Notice of Disbursement from Decommissioning Trust ML24053A2572024-03-0101 March 2024 Withdrawal of Requested Licensing Action for a License Amendment Submitted for Approval of the License Termination Plan BVY 24-009, Withdrawal of License Amendment Request to Add License Condition 3.K, License Termination Plan; Proposed Change No. 3172024-02-27027 February 2024 Withdrawal of License Amendment Request to Add License Condition 3.K, License Termination Plan; Proposed Change No. 317 BVY 24-008, ISFSI, Annual Radioactive Effluent Release Report2024-02-26026 February 2024 ISFSI, Annual Radioactive Effluent Release Report BVY 24-007, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-02-26026 February 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G IR 05000271/20230022024-02-20020 February 2024 NRC Inspection Report Nos. 05000271/2023002 and 07200059/2023001, Northstar Nuclear Decommissioning Company, LLC, Vermont Yankee Nuclear Power Station, Vernon, Vermont BVY 24-006, Pre-Notice of Disbursement from Decommissioning Trust2024-02-0606 February 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 24-005, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-01-30030 January 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-004, Report of Investigation Pursuant to 10 CFR 20, Appendix G2024-01-23023 January 2024 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 24-003, Nuclear Onsite Property Damage Insurance2024-01-0404 January 2024 Nuclear Onsite Property Damage Insurance BVY 24-001, Pre-Notice of Disbursement from Decommissioning Trust2024-01-0202 January 2024 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-030, Report of Investigation Pursuant to 10 CFR 20, Appendix G2023-12-20020 December 2023 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 23-029, Proof of Financial Protection2023-12-12012 December 2023 Proof of Financial Protection BVY 23-028, Pre-Notice of Disbursement from Decommissioning Trust2023-11-28028 November 2023 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-027, Report of Investigation Pursuant to 10 CFR 20, Appendix G2023-11-21021 November 2023 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 23-026, Report of Investigation Pursuant to 10 CFR 20, Appendix G2023-11-13013 November 2023 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 23-025, Pre-Notice of Disbursement from Decommissioning Trust2023-11-0202 November 2023 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-023, License Amendment Request Addition of License Condition 3.K, License Termination Plan; Proposed Change No. 3172023-10-10010 October 2023 License Amendment Request Addition of License Condition 3.K, License Termination Plan; Proposed Change No. 317 IR 07200059/20234012023-10-0505 October 2023 Independent Spent Fuel Storage Installation Security Inspection Report 07200059/2023401 BVY 23-022, Pre-Notice of Disbursement from Decommissioning Trust2023-08-23023 August 2023 Pre-Notice of Disbursement from Decommissioning Trust IR 05000271/20230012023-08-15015 August 2023 Northstar Nuclear Decommissioning Company, Llc., Vermont Yankee Nuclear Power Station, - NRC Inspection Report 05000271/2023001 BVY 23-021, Report of Investigation Pursuant to 10 CFR 20, Appendix G2023-08-0202 August 2023 Report of Investigation Pursuant to 10 CFR 20, Appendix G BVY 23-020, Pre-Notice of Disbursement from Decommissioning Trust2023-08-0202 August 2023 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-019, Update to 2022 Radiological Effluent Release Report2023-07-24024 July 2023 Update to 2022 Radiological Effluent Release Report BVY 23-018, Update to Nuclear Onsite Property Damage Insurance2023-07-12012 July 2023 Update to Nuclear Onsite Property Damage Insurance BVY 23-017, Pre-Notice of Disbursement from Decommissioning Trust2023-06-29029 June 2023 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-015, Report of Investigation Pursuant to 1O CFR 20, Appendix G2023-06-0505 June 2023 Report of Investigation Pursuant to 1O CFR 20, Appendix G BVY 23-016, 10 CFR 72.48 Report2023-06-0505 June 2023 10 CFR 72.48 Report BVY 23-014, Pre-Notice of Disbursement from Decommissioning Trust2023-05-31031 May 2023 Pre-Notice of Disbursement from Decommissioning Trust BVY 23-011, 2022 Radiological Effluent Release Report2023-05-10010 May 2023 2022 Radiological Effluent Release Report BVY 23-013, 2022 Radiological Environmental Operating Report2023-05-10010 May 2023 2022 Radiological Environmental Operating Report BVY 23-012, Pre-Notice of Disbursement from Decommissioning Trust2023-05-0202 May 2023 Pre-Notice of Disbursement from Decommissioning Trust 2024-09-18
[Table view] |
Text
December 29, 2004 Ms. Fenna Lee Bonsigniore, Chair Selectboard of Leverett Massachusetts 9 Montague Road Leverett, MA 01054
Dear Ms. Bonsigniore:
I am responding on behalf of the Nuclear Regulatory Commission (NRC) to your letter to Entergy Nuclear Operations (Entergy), dated November 18, 2004, a copy of which was sent to the NRC. Your letter expressed concerns with the request by Entergy to amend the Vermont Yankee Nuclear Power Station (Vermont Yankee) operating license to increase the power level of the facility by 20%. In that letter, you requested that Entergy perform an in-depth independent engineering assessment before any increase in capacity is considered.
As you noted in your letter, the NRC has conducted an engineering inspection of Vermont Yankee. The inspectors used operating experience, risk assessment, and engineering analysis to select risk-significant components and operator actions for detailed reviews. A portion of the inspection sample was from systems or components that would be potentially affected by a power uprate. Three weeks of onsite inspection and over 900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> of direct inspection time were conducted at the Vermont Yankee site. The inspection team concluded that the components and systems reviewed would be capable of performing their intended safety functions. The team also concluded that sufficient design controls had been implemented for design and engineering work, including those related to Entergys proposed extended power uprate. The inspection team did identify eight deficiencies of low safety significance related to design control at Vermont Yankee; however, sample-based extent-of-condition reviews indicated the original problems were not widespread or programmatic in nature. With regard to the impact of these findings on the proposed power uprate, the NRC staff is still reviewing the licensees power uprate request. As such, we have not reached any conclusions concerning the acceptability of the proposed uprate. We believe that the extensive technical review performed by the NRC staff, along with the ongoing NRC inspection program, provide assurance that any issues that could affect safe operation of the plant, related to the proposed power uprate, will be identified. The NRC will not approve the Vermont Yankee uprate, or any proposed change to a plant license, unless the NRC can conclude that the proposed change will be executed in a manner that assures the publics health and safety.
You requested an informational meeting with the NRC in the community. The Vermont State Nuclear Advisory Panel hosted a meeting with the NRC on December 16, 2004, in Brattleboro, Vermont. The purpose of this meeting was to discuss the findings from the engineering inspection discussed above, and the inspection into the two misplaced fuel rod pieces.
Because the NRC staff has not yet completed its review of the Vermont Yankee power uprate application, it would be premature to engage in discussion of the power uprate proposal at this time. The NRC staff expects to hold a meeting in the future to discuss the proposed power uprate.
You also requested information about compensation should there be loss of life, illness, or loss of property due to an accident involving radiation release at Vermont Yankee. The Price-
Ms. F. Bonsigniore Anderson Act, which was enacted in 1957, provides a system to pay funds for claims by members of the public for personal injury and property damage resulting from a nuclear incident. The Act would cover claims for damage from operation of the reactor as well as for storage of spent fuel at the reactor site. The Act provides approximately $10 billion in insurance to pay these claims under a two-layer insurance system. Large commercial reactor licensees, such as Vermont Yankee, participate in this system . The first layer provides $300 million in private insurance , the maximum currently available from the private insurance market. In the event of a nuclear incident causing damages exceeding $300 million, large reactor licensees would be assessed an equal share of the damages in excess of the primary insurance layer.
This deferred premium, or secondary layer, is currently $95.8 million per reactor. With over 100 reactors in this layer, total insurance is approximately $10 billion.
Thank you for your interest in the NRCs activities related to Vermont Yankee. Please contact me at 301-415-3036 if you would like to discuss any of the information provided in this letter.
Sincerely,
/RA/
Cornelius F. Holden, Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
Ms. F. Bonsigniore Anderson Act, which was enacted in 1957, provides a system to pay funds for claims by members of the public for personal injury and property damage resulting from a nuclear incident. The Act would cover claims for damage from operation of the reactor as well as for storage of spent fuel at the reactor site. The Act provides approximately $10 billion in insurance to pay these claims under a two-layer insurance system. Large commercial reactor licensees, such as Vermont Yankee, participate in this system . The first layer provides $300 million in private insurance , the maximum currently available from the private insurance market. In the event of a nuclear incident causing damages exceeding $300 million, large reactor licensees would be assessed an equal share of the damages in excess of the primary insurance layer.
This deferred premium, or secondary layer, is currently $95.8 million per reactor. With over 100 reactors in this layer, total insurance is approximately $10 billion.
Thank you for your interest in the NRCs activities related to Vermont Yankee. Please contact me at 301-415-3036 if you would like to discuss any of the information provided in this letter.
Sincerely,
/RA/
Cornelius F. Holden, Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation DISTRIBUTION:
PUBLIC PDI-2 R/F JDyer WBorchardt BSheron CCarpenter GMatakas, Rgn I CHolden VBucci, OIG LCox REnnis CRaynor DSkay NRR Mail Room (Y020040251)
AHowe JStang BPoole, OGC Package No.: ML0043500587 Response No.: ML043500563 Incoming No.: ML043430361 OFFICE PDI-1/PM PDI-2/LA VY/SC PDI/PD NAME DSkay CRaynor AHowe CHolden DATE 12/22/04 12/21/04 12/17/04 12/22/04 OFFICIAL RECORD COPY