Staff Discussion Items for NEI 10-05 (Rev. 0) Related to On-Shift Emergency Response Organization Staffing Analysis Process
ML110590718
Person / Time
Issue date: 02/28/2011
From:
Office of Nuclear Security and Incident Response
To:
Nuclear Energy Institute
anderson, Joseph NSIR/DPR 415-4114
References
Download: ML110590718 (2)


Text

NRC Staff Discussion Items Related to the On-Shift Emergency Response Organization Staffing Analysis Process (NEI 10-05, Revision 0)

  1. Page Section Discussion Item 1 Throughout Throughout Licensees should perform analysis for events provided in the Interim Staff Guidance, NSIR/DPR-ISG-01, EMERGENCY PLANNING FOR NUCLEAR POWER PLANTS.

2 4 2.3 At a minimum, the number and composition of the on-shift staff credited in the staffing analysis must be reflected in the commitments within each sites emergency plan.

3 4 2.5 Section IV.A.9 of Appendix E to 10 CFR 50 requires licensees to perform the detailed analysis to determine if on-shift staff may be assigned additional responsibilities that would prevent the timely performance of their emergency response functions delineated in the emergency plan. Any changes to the on-shift staffing, augmented staffing or augmentation staffing timing are subject to the requirements of 10 CFR 50.54(q) and related guidance.

4 6 3.1.3 The on-shift personnel complement is limited to the minimum required number and composition as reflected in the commitments within the sites emergency plan.

Licensees may have other personnel on shift required by other commitments (i.e,, Appendix R), these personnel may be included in the analysis only if they are reflected as on shift in the sites emergency plan.

5 7 3.1.5 assigned actions. For DBT events, licensees should evaluate the effects of station Security/Operations procedures upon the response times of the on-shift personnel, i.e., movement of personnel secured or two-man rule. Licensees should.

6 8 3.1.10 enforcement. This does not include off-site notifications as provided in Table 5.

7 8 3.1.12 Repair and Corrective Actions: controls to complete.

Examples of Repair and Corrective actions may include:

(1) Electrician: Responsible for providing electrical support for ECCS equipment, event mitigation, and equipment repair.

(2) Mechanic: Responsible for providing mechanical support for ECCS equipment, event mitigation, and equipment repair.

February 28, 2011 Page 1

NRC Staff Discussion Items Related to the On-Shift Emergency Response Organization Staffing Analysis Process (NEI 10-05, Revision 0)

(3) I&C Technician: Responsible for providing assist with logic manipulation, for providing I&C support for event mitigation and equipment repair, and for support of digital I&C if applicable.

(4) Rad Waste Operator: Responsible for Rad Waste Operations required by applicable site procedures, e.g.,

EOP, AOP, EPIPs, etc.

8 8 3.1.12 Licensees should review applicable site procedures, e.g., EOP, AOP, EPIPs, etc, to determine if support/actions by Mechanical/Electrical/I&C are required under the Major Functional Area of Repair or Corrective Actions.

9 8 3.2.1 Complete Appendix A for events identified in Interim Staff Guidance NSIR/DPR-ISG-01, Emergency Planning For Nuclear Power Plants.

10 10 3.2.2.2.c Maintenance/Electrical/I&C personnel if identified in Step 3.1.12.

11 11 3.2.2.5.a emergency plan implementing procedures.

12 12 3.2.2.5.b Chemistry Technician (as indicated in Table 5).

13 13 3.2.2.6.a.12 It should be noted that the NRC may request an open, continuous communication channel IAW 10 CFR 50.72.(a)(3).

14 15 3.2.3.2 An additional notification block should be added for DBT Table events. Perform NRC abbreviated notification for DBT events.

15 15 3.2.3.2 Perform NRC communications (It should be noted that Table the NRC may request an open, continuous communication channel) 16 B-6 Table 4 Offsite Radiological Assessment (as indicated in Table 5) 17 B-7 Table 5 An additional notification block should be added for DBT events. Perform NRC abbreviated notification for DBT events.

18 B-7 Table 5 Perform NRC communications (It should be noted that the NRC may request an open, continuous communication channel)

February 28, 2011 Page 2