ML14336A279

From kanterella
Revision as of 20:00, 31 October 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
FEMA, Quad Cities Nuclear Power Station, Final After Action Report/Improvement Plan, Radiological Emergency Preparedness Program
ML14336A279
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 11/20/2014
From: Odeshoo J
US Dept of Homeland Security, Federal Emergency Management Agency
To: Pederson C
NRC/RGN-III
Barker A
References
Download: ML14336A279 (2)


Text

U.S. Department of Homeland Security FEMA Region V 536 South Clark Street, 6th Floor Chicago, IL 60605 FEMA Ms. Cynthia Pederson NOV 2 0 t014 Regional Administrator U.S. Nuclear Regulatory Commission Region III 2443 Warrenville Road, Suite 210 Lisle, Illinois 60542-4351

Dear Ms. Pederson:

Enclosed is one copy of the Final After Action Report/Improvement Plan for the August 27, 2014, Quad Cities Station Radiological Emergency Preparedness Full Participation Plume Exposure Pathway Hostile Action Based Exercise.

No Deficiencies or Areas Requiring Corrective Action (ARCA) were identified for the State of Illinois and the Counties of Rock Island and Whiteside during this exercise. There was one Plan Issue for the State of Illinois and the Counties of Rock Island and Whiteside. There was one ARCA resolved for the Counties of Rock Island and Whiteside.

The ARCA that was resolved for Rock Island County was identified under Criterion 5.a.1 -

Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

The ARCA that was resolved for Whiteside County was identified under Criterion 5.a.1 -

Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

The Plan Issue that was identified for the State of Illinois was identified under Criterion 5.b.1

-OROs provide accurate emergency information and instructions to the public and news media in a timely manner.

The Plan Issue that was identified for Rock Island County was identified under Criterion 5.a.l -Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

www.fema.gov RECEIVED DEC 0 2 Z014

Pederson Page 2 The Plan Issue that was identified for Whiteside County was identified under Criterion 5 .a.l -

Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

Copies of this report were transmitted to the Nuclear Regulatory Commission Headquarters' Document Control Desk and the State of Illinois.

If you have any questions, please contact Stephen E. Tulley, Co-Chairman, Regional Assistance Committee, United States Department of Homeland Security/Federal Emergency Management Agency (DHS/FEMA), Region V, at (312) 408-4425 or Christopher W. Roe, Technological Hazards Program Specialist, DHS/FEMA, Region Vat (312) 408-5392.

Sincerely,

~*~

Janet M. Odeshoo Acting Regional Administrator Enclosures (1)