ERDS Data Point Library Update - R.E. Ginna Nuclear Power Plant
ML15205A318
Person / Time
Site: Ginna Constellation icon.png
Issue date: 07/16/2015
From: Harding T
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
WPLNRC-10002985
Download: ML15205A318 (4)


Text

R.E. Ginna Nuclear Power Plant wf-Exelon Generation.. 1503 Lake Rd.

Ontario, NY 14519 www.exeloncorp.com July 16, 2015 10 CFR 50 Appendix E U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 2055-0001 R.E. Ginna Nuclear Power Plant Facility Operating License No. DPR- 18 NRC Docket No. 50-244

Subject:

ERDS Data Point Library Update In accordance with 10 CFR 50 Appendix E, Emergency Planning and Preparedness for Production and Utilization Facilities,Section VI, Emergency Response Data System, paragraph 3.a, and NUREG-1394, Emergency Response Data System (ERDS) Implementation, revision 1 Section 3.6, Administrative Implementation Requirements, the R.E. Ginna Nuclear Power Plant is providing an update to the ERDS Data Point Library (DPL). The changes are included in Attachment 1.

There are no regulatory commitments contained in this letter.

Should you have any questions regarding this submittal, please contact Thomas Harding at 315-791-5219.

Respectfully, Thomas Harding Manager, Regulatory Assurance R.E. Ginna Nuclear Power Plant, LLC TH/kc

Attachment:

(1) ERDS Data Point Library Update cc: NRC Regional Administrator, Region I NRC Project Manager, Ginna NRC Resident Inspector, Ginna A "~'~

(~JPLN~(-~/ ~Cc9q8*

Attachment (1)

ERDS Data Point Library Update

EP-20150709-00002 ERDS DATA POINT LIBRARY Da tapoint 63 of 64

1) Date: 6/19/15
2) Reactor Unit: GIl (Ginna)
3) Data Feeder: N/A
4) NRC ERDS Parameter: STAB CLASS
5) Plant Point ID: WT150
6) Plant Specific Point

Description:

150 FOOT LEVEL TEMPERATURE

7) Generic/Condensed

Description:

AIR STABILITY AT REACTOR SITE

8) Analog/Digital: ANALOG
9) Engineering Units or Digital States: DEGF
10) Engineering Units Conversion: N/A
11) Minimum Instrument Range: -20 F
12) Maximum Instrument Range: 120 F
13) Zero Point

Reference:

N/A

14) Reference Point Notes: N/A
15) Process or Sensor: SENSOR
16) Number of Sensors: 1
17) How Processed: N/A
18) Sensor Locations: MET TOWER NORTHWEST OF PLANT
19) Alarm/Trip Setpoints: N/A
20) NI Detector Power Supply Cut-Off Po3wer Level: N/A
21) NI Detector Power Supply Turn-On Psower Level: N/A
22) Instrument Failure Mode: N/A
23) Temperature Compensation for DP T*ransmitters: N/A
24) Level Reference Leg: N/A
25) Unique System

Description:

N/A

EP-20150709-00003 ERDS DATA POINT LIBRARY Da tapoint 64 of 64

1) Date: 6/19/15
2) Reactor Unit: Gil (Ginna)
3) Data Feeder: N/A
4) NRC ERDS Parameter: STAB CLASS
5) Plant Point ID: WDT1
6) Plant Specific Point

Description:

150 TO 33 FOOT LEVEL DELTA TEMP

7) Generic/Condensed

Description:

AIR STABILITY AT REACTOR SITE

8) Analog/Digital: ANALOG
9) Engineering Units or Digital States: DEGF
10) Engineering Units Conversion: N/A
11) Minimum Instrument Range: -10 F
12) Maximum Instrument Range: 10F
13) Zero Point

Reference:

N/A

14) Reference Point Notes: N/A
15) Process or Sensor: PROCESS
16) Number of Sensors: 2
17) How Processed: D/F
18) Sensor Locations: MET TOWER NORTHWEST OF PLANT
19) Alarm/Trip Setpoints: N/A
20) NI Detector Power Supply Cut-Off Po wer Level: N/A
21) NI Detector Power Supply Turn-On P ower Level: N/A
22) Instrument Failure Mode: N/A
23) Temperature Compensation for DP Transmitters: N/A
24) Level Reference Leg: N/A
25) Unique System

Description:

A: <-1.17F B: > -1.17F and < -1.05F C: > -1.05F and < -0.94F D: > -0.94F and < -0.35F E: > -0.35F and < +0.94F F: > +0.94F and < +2.57F G: > +2.57F