wf-Exelon Generation..

R.E. Ginna Nuclear Power Plant 1503 Lake Rd.

Ontario, NY 14519 www.exeloncorp.com July 16, 2015 10 CFR 50 Appendix E U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 2055-0001 R.E. Ginna Nuclear Power Plant Facility Operating License No. DPR-18 NRC Docket No. 50-244

Subject:

ERDS Data Point Library Update In accordance with 10 CFR 50 Appendix E, Emergency Planning and Preparedness for Production and Utilization Facilities,Section VI, Emergency Response Data System, paragraph 3.a, and NUREG-1394, Emergency Response Data System (ERDS) Implementation, revision 1 Section 3.6, Administrative Implementation Requirements, the R.E. Ginna Nuclear Power Plant is providing an update to the ERDS Data Point Library (DPL). The changes are included in Attachment 1.

There are no regulatory commitments contained in this letter.

Should you have any questions regarding this submittal, please contact Thomas Harding at 315-791-5219.

Respectfully, Thomas Harding Manager, Regulatory Assurance R.E. Ginna Nuclear Power Plant, LLC TH/kc

Attachment:

(1)

ERDS Data Point Library Update cc:

NRC Regional Administrator, Region I NRC Project Manager, Ginna NRC Resident Inspector, Ginna A "~'~

(~JPLN~(-~/ ~Cc9q8*

Attachment (1)

ERDS Data Point Library Update

1) 2)

3) 4)

5) 6)

7) 8)

9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25)

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Plant Point ID:

Plant Specific Point

Description:

Generic/Condensed

Description:

Analog/Digital:

Engineering Units or Digital States:

Engineering Units Conversion:

Minimum Instrument Range:

Maximum Instrument Range:

Zero Point

Reference:

Reference Point Notes:

Process or Sensor:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Setpoints:

NI Detector Power Supply Cut-Off Po NI Detector Power Supply Turn-On P Instrument Failure Mode:

Temperature Compensation for DP T Level Reference Leg:

Unique System

Description:

EP-20150709-00002 ERDS DATA POINT LIBRARY Da 6/19/15 GIl (Ginna)

N/A STAB CLASS WT150 150 FOOT LEVEL TEMPERATURE AIR STABILITY AT REACTOR SITE ANALOG DEGF N/A

-20 F 120 F N/A N/A SENSOR 1

N/A MET TOWER NORTHWEST OF PLANT N/A 3wer Level:

N/A sower Level:

N/A N/A

  • ransmitters:

N/A N/A N/A tapoint 63 of 64

1) 2)

3) 4)

5) 6)

7) 8)

9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25)

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Plant Point ID:

Plant Specific Point

Description:

Generic/Condensed

Description:

Analog/Digital:

Engineering Units or Digital States:

Engineering Units Conversion:

Minimum Instrument Range:

Maximum Instrument Range:

Zero Point

Reference:

Reference Point Notes:

Process or Sensor:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Setpoints:

NI Detector Power Supply Cut-Off Po NI Detector Power Supply Turn-On P Instrument Failure Mode:

Temperature Compensation for DP T Level Reference Leg:

Unique System

Description:

EP-20150709-00003 ERDS DATA POINT LIBRARY Da 6/19/15 Gil (Ginna)

N/A STAB CLASS WDT1 150 TO 33 FOOT LEVEL DELTA TEMP AIR STABILITY AT REACTOR SITE ANALOG DEGF N/A

-10 F 10F N/A N/A PROCESS 2

D/F MET TOWER NORTHWEST OF PLANT N/A wer Level:

N/A ower Level:

N/A N/A ransmitters:

N/A N/A A: <-1.17F B: > -1.17F and < -1.05F C: > -1.05F and < -0.94F D: > -0.94F and < -0.35F E: > -0.35F and < +0.94F F: > +0.94F and < +2.57F G: > +2.57F tapoint 64 of 64