ES-301 Control Room/In
-Plant Systems Outline Form ES-301-2 Facility: _Byron Nuclear Station_______
Date of Examination:
_02/29/2013__________
Exam Level: RO / SRO-I / SRO-U Operating Test No.: __2013301___________
Control Room Systems
-I; 2 or 3 for SRO
-U) System / JPM Title Type Code*
Safety Function a. Purification / Excess Letdown Operation P, D, S 1 b. Purification / Letdown Orifice Operation N, S 2 c. RHR / Swap to HL Recirc M,A,EN,L,S 3 d. SX / Align SX Twr for LOCA Conditions D,A,E,EN,L,S 4S e. CS / Align CS for Recirc D,A,E,EN,L,S 5 f. AC Elec / Sync a SAT to a Bus Being Fed by a D/G D, S 6 g. Change RM-11 Setpoints in Preparation for WGDT Release D, S 9 h. Prepare U-1 for RSDP Ops D, L, S 8 In-Plant Systems
-I; 3 or 2 for SRO
-U) i. RSP / Trip the Reactor Outside the Control Room D, A, E, EN 1 j. DC Elec / Place Battery on Equalize Charge N, A 6 k. FP Cool / Align FP Cooling for CV Pp D, E, L, R 4S @ All control room (and in
-plant) systems must be different and serve different safety functions; in
-plant systems and functions may overlap those tested in the control room.
-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in
-plant (L)ow-Power (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1 ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: _Byron Nuclear Station_______
Date of Examination: _02/29/2013__________
Exam Level: RO / SRO-I / SRO-U Operating Test No.: __2013301___________
Control Room Systems
-I; 2 or 3 for SRO
-U) System / JPM Title Type Code*
Safety Function a. Purification / Excess Letdown Operation P, D, S 1 b. Purification / Letdown Orifice Operation N, S 2 c. RHR / Swap to HL Recirc M,A,EN,L,S 3 d. SX / Align SX Twr for LOCA Conditions D,A,E,EN,L,S 4S e. CS / Align CS for Recirc D,A,E,EN,L,S 5 f. AC Elec / Sync a SAT to a Bus Being Fed by a D/G D, S 6 g. n/a n/a 9 h. Prepare U-1 for RSDP Ops D, L, S 8 In-Plant Systems
-I; 3 or 2 for SRO
-U) i. RSP / Trip the Reactor Outside the Control Room D, A, E, EN 1 j. DC Elec / Place Battery on Equalize Charge N, A 6 k. FP Cool / Align FP Cooling for CV Pp D, E, L, R 4S @ All control room (and in
-plant) systems must be different and serve different safety functions; in
-plant systems and functions may overlap those tested in the control room.
-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in
-plant (L)ow-Power (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1 ES-301 Control Room/In
-Plant Systems Outline Form ES-301-2 Facility: _Byron Nuclear Station_______
Date of Examination: _02/29/2013__________
Exam Level: RO / SRO-I / SRO-U Operating Test No.: __2013301___________
Control Room Systems
-I; 2 or 3 for SRO
-U) System / JPM Title Type Code*
Safety Function a. n/a n/a b. Purification / Letdown Orifice Operation N, S 2 c. n/a n/a d. n/a n/a e. CS / Align CS for Recirc D,A,E,EN,L,S 5 f. n/a g. n/a n/a 9 h. n/a n/a In-Plant Systems
-I; 3 or 2 for SRO
-U) i. RSP / Trip the Reactor Outside the Control Room D, A, E, EN 1 j. DC Elec / Place Battery on Equalize Charge N, A 6 k. FP Cool / Align FP Cooling for CV Pp D, E, L, R 4S @ All control room (and in
-plant) systems must be different and serve different safety functions; in
-plant systems and functions may overlap those tested in the control room.
-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in
-plant (L)ow-Power (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1