Title | Unit 1 Pressurizer Safety Valve Lift Pressure Outside of Technical Specification Tolerance Band |
Description | A self-revealed SL IV NCV of TS 3.4.10, Pressurizer Safety Valves, was identified when a routine lift pressure test revealed that pressurizer safety valve Q1B13V0031C was lower than allowed by TS SR 3.4.10.1 for a duration that was longer than the conditions TS required action completion time. |
Site: | Farley |
---|---|
Report | IR 05000348/2018003 Section 4OA3 |
Date counted | Sep 30, 2018 (2018Q3) |
Type: | TEV: Severity level IV |
cornerstone | No Cornerstone |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | P Niebaum M Schwieg K Miller D Mas-Penaranda A Blamey |
Violation of: | Technical Specification |
INPO aspect | |
' | |
Finding - Farley - IR 05000348/2018003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Farley) @ 2018Q3