Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML19354C43718 July 1974AO 50-219/74/36:on 740710,RE03D Reactor High Pressure Sensor Failed to Trip at Point Less than or Equal to 1,060 Psig. Caused by Lack of Allowance for Setpoint Tolerances in Tech Specs.Sensor Recalibr & Returned to Svc
ML20003C37926 April 1974AO 50-219/74/29:on 740423,electromatic Relief Valve Pressure Switches 1A83B & 1A83D Tripped at Pressures in Excess of Max Allowable Value of 1,070 Psig.Caused by Instrument Drift. Switches Reset
ML20003C38026 April 1974AO 50-219/74-27:on 740417,insp Revealed Bergen-Paterson Hydraulic Shock & Sway Arrestors in Drywell Inoperable.Cause Undetermined.Units Will Be Replaced During Present Refueling Outage
ML20003C38122 April 1974AO 50-219/74/26:on 740412,emergency Svc Water Pump 52C Failed to Start.Caused by Thermal Overload Relay Coupled W/ Excess Current Relay.Feasibility Study Re Thermal Overload Relay Removal from Trip Circuits to Be Made
ML20003C38219 April 1974AO 50-219/74/24:on 740409,stack Gas Particulate Filter in Svc from 740328-31 Not Analyzed for Gross Beta,Gross Alpha & Gross Gamma as Required.Caused by Technician Error. Administrative Control to Be Tightened
ML20003C38319 April 1974AO 50-219/74/28:on 740419,suction Valve V-20-4 to Core Spray Pump B Stuck in Closed Position for 15 Minutes,Causing Loss of Core Spray Redundancy in Sys 2.Cause Undetermined.Valve Manually Opened & Circuit Breaker Tagged Open
ML20003C38419 April 1974AO 50-219/74/25:on 740409,butterfly Valve V-26-16 Found Open & Primary Containment Integrity Lost W/Reactor Critical & Water Temp Greater than 212F.Caused by Component Failure. Valve Manually Forced to Seat Properly & Shutdown Commenced
ML20003C38518 April 1974AO 50-219/74/27:on 740417,insp Revealed Bergen-Paterson Hydraulic Shock & Sway Arrestors in Drywell Inoperable.Cause Undetermined.Units Will Be Replaced During Present Refueling Outage
ML20003C38710 April 1974AO 50-219/74/25:on 740409,butterfly Valve V-26-16 Found Open & Primary Containment Integrity Lost W/Reactor Critical & Water Temp Greater than 212F.Cause of Component Failure Not Known.Valve Manually Forced to Seat Properly
ML20003C38810 April 1974AO 50-219/74-24:on 740409,stack Gas Particulate Filter in Svc from 740328-31 Not Analyzed for Gross Beta,Gross Alpha & Gross Gamma as Required.Cause Being Investigated
ML20003C38925 March 1974AO 50-219/74/23:on 740315,isolation Condenser Condensate High Flow Sensors Actuated at Setpoints Above Tech Specs Limits.Caused by Lack of Sensor Repeatability.Procedures Being Revised to Reflect Setpoint Changes
ML20003C39022 March 1974AO 50-219/74/21:on 740313,bypass Valve RE22D Opened,Causing Main Steam High Flow Sensor RE22D to Be Inoperable.Caused by Incorrect Valve Positioning.Instrument Technicians to Be Advised Re Critical Importance of Valve Lineup Checks
ML20003C39122 March 1974AO 50-219/74/22:on 740315,low Pressure Main Steam Line Pressure Switch RE23D Tripped at Pressure Less than Min Required Value of 860 Psig.Caused by Switch Repeatability & Design.Basis for Steam Line Low Pressure Setting StudiedFuel cladding
ML20003C39218 March 1974AO 50-219/74/20:on 740310,MSIVs NS04A & NS04B Failed to Meet Allowable Leakage Requirements.Caused by Faulty Lower Packing Rings Around Valve Shaft.Valves Closed Until 1974 Refueling Outage
ML20003C39313 March 1974AO-50-219/74/21:on 740313,bypass Valve RE22D Opened,Causing Main Steam High Flow Sensor RE22D to Be Inoperable.Cause Under Investigation.Instrument Technicians to Be Advised Re Critical Importance of Valve Lineup Checks
ML20003C3948 March 1974AO 50-219/74/17:on 740307,power Operation Continued W/Sb Startup Transformer Unavailable for Svc for Time Period Greater than Tech Specs Limits.Caused by Failure of Cam Switch Contacts.Corrective Action to Be Determined
ML20003C3957 March 1974AO 50-219/74/15:on 740228,torus to Drywell Breaker Failed to Demonstrate Operability During Weekly Testing.Caused by Design Error Resulting in Excess Friction in Valve Hinge Pins.Valve Locked in Closed Position Pending Solution
ML20003C3971 March 1974AO 50-219/74/14:on 740222,two Torus to Drywell Breakers Failed to Demonstrate Operability During Weekly Surveillance Testing.Caused by Excess Friction in Valve Hinge Pins.Valves Freed Immediately W/Repetitive Opening & Closing Movements
ML20003C39927 February 1974AO 50-219/74/13:on 740218,cleanup Sys Ac Isolation Valve V-16-1 Inoperable W/Reactor Critical & Coolant Temp Above 212F.Caused by Inadvertent Opening of Valve V-16-1 Breaker. Breaker re-energized & Painting Contractor Personnel Warned
ML20003C40025 February 1974AO 50-219/74/12:on 740215,low Pressure Main Steam Line Pressure Switches RE23A & B Tripped at Pressures Less than Min Required Value of 860 Psig.Caused by Design Error. Investigation in Progress & Tech Specs Change May FollowFuel cladding
ML20003C40125 February 1974AO 50-219/74/11:on 740215,four Torus to Drywell Vacuum Breakers Failed to Demonstrate Operability During Weekly Surveillance Testing.Caused by Excess Friction in Valve Hinge Pines.Valves Freed W/Opening & Closing Movements
ML20003C40214 February 1974AO 50-219/74/10:on 740208,low Pressure Main Steam Line Pressure Switches RE23A,C & D Tripped at Pressure Less than Min Required Value of 860 Psig.Caused by Design Error & Sensor Drift.Investigation of Setpoint Drift in ProgressFuel cladding
ML20003C4036 February 1974AO 50-219/74/9:on 740131,low Pressure Main Steam Line Pressure Switches RE23A & D Tripped at Pressures Less than Specified Value.Caused by Design Error & Unusual Svc Conditions.Study Re Basis for Specified Setting in ProgressFuel cladding
ML20003C72118 March 1974Ao:On 740309,during Shutdown to Perform Maint on Six Torus to Drywell Vacuum Breaker Valves,Recirculation Loop Temp Recorder Indicated 160 F,Then Jumped to 250 F When Bumped. Caused by Equipment Malfunction & Operator Error
ML20003C72218 March 1974AO 50-219/74/18:on 740308,w/plant Shutdown,Insp of Drywell Snubbers Located Three Inoperable & Four Leaking.Caused by Loss of Hydraulic Fluid.Units Replaced W/Identical Snubbers Rebuilt W/Ethylene Propylene SealsDesign basis earthquake
ML20003C72315 March 1974AO 50-219/74/17:on 740307,during Routine Plant Shutdown, While Transferring Power from 1B Auxiliary Transformer to SB Startup Transformer,Closing Switch for S1B Breaker Failed. Caused by Component Failure.Switchgears Will Be Checked
ML20003C72415 March 1974AO 50-219/74/16:on 740307,while at Steady State Power,During Weekly Surveillance Testing on 14 Torus to Drywell Vacuum Breakers,Four Breakers Failed to Demonstrate Operability. Caused by Excess Friction in Valve Hinge Pins
ML20083Q02127 February 1973Ao:On 730212,low Sample Flow Identified in Stack Monitor Sys.Caused by Moisture Freezing in Sample Line at 262-ft Elevation.Line Thawed Out
ML20083Q03917 January 1973Ao:On 721229,electromatic Relief Valve Failed to Reset Causing Primary Sys Blowdown Following Reactor Scram.As Result,Three Different Valves Failed to Operate in Intended Manner.Manufacturers & Valve Users Will Be ConsultedBreakaway torque
ML20083R19024 May 1972Ao:On 711031,fuel Assembly Jc 359 Found Misoriented,As Result of Investigation of 720506 Incident Where Operator Unable to Position Sipper Head on Control Head 26-07.Visual Insp of Assembly Conducted
ML20084A09029 October 1973Ao:On 730915,following Investigation of Excess Letdown Line Leak,Valve 1MOV-1299 Downstream Seat Protruded from Valve Body & Crack Discovered in Upper Portion of Downstream Seat Ring.Cause Unknown.Vendor Notified of Valve Problem
ML20084B71226 June 1972Ao:On 720524,essential Svc Motor Generator Set Failed Resulting in Feedwater Control Sys Failure & Reactor Scram. Caused by Dirty Contacts on 2K Relay.Hfa Relay Replaced
ML20084C39421 October 1974AO 50-219/74-52:on 741012,main Steam Line Low Pressure Switch RE23A Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Ge Supplied Info to Reduce Setpoint
ML20084C41915 October 1974Preliminary AO 50-219/74/52:on 741012,main Steam Low Pressure Switch RE23A Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Ge Supplied Info to Enable Reduction in Setpoint
ML20084C43524 October 1974AO 50-219/74-53:on 741015,stack Gas Sample Sys Discovered Not Functioning Properly While Reactor Not in Isolated Condition.Caused by Excessive Air Flow to Pump Thereby Reducing Vacuum of Filter.Loose Fitting Tightened
ML20084C47815 October 1974Preliminary AO 50-219/74-53:on 741014,stack Gas Sample Sys Discovered Not Functioning Properly While Reactor Not in Isolated Condition.Caused by Excessive Air Flow to Pump Reducing Vacuum at Filter.Loose Fitting Replaced
ML20084C50511 October 1974AO 50-219/74-51:on 741007,main Steam Line Low Pressure Switches RE23B & C Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Ge Supplied Info Re Reduction of Setpoint.Info Being EvaluatedFuel cladding
ML20084C52611 October 1974AO 50-219/74-50:on 741004,cleanup Sys Dc Isolation Valve V-16-14 Failed to Close Electrically.Caused Undetermined. Arc Horn on Contactor 2Bc Replaced
ML20084C5454 October 1974AO 50-219/74-49:on 740927,main Steam Line Low Pressure Switch RE23A Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Ge Supplied Info to Reduce SetpointFuel cladding
ML20084C5574 October 1974AO 50-219/74-48:on 740925,isolation Condensers a & B Inoperable Due to High Flow as Sensed by Condensate Line Break Sensors.Caused by Tripping of Line Break Sensors Due to Effects of Rated Recirculation Flow
ML20084C58030 September 1974Preliminary AO 50-219/74-48:on 740927,main Steam Line Low Pressure Switch RE23A Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Ge Submitted Info to Reduce SetpointFuel cladding
ML20084C63826 September 1974Preliminary AO 50-219/74-48:on 740925,isolation Condensers a & B Isolated Due to False High Flow Indication on Condensate Line Break Sensors.Cause Under Investigaion.Surveillance Testing Performed on All Condensate Line Break Sensors
ML20084C65123 September 1974AO 50-219/74-47:on 740912,two Bergen-Paterson Hydraulic Shock & Sway Arrestors on South Core Spray Sys Found Inoperable.Caused by Component Failure.Two Snubbers Replaced W/Units Rebuilt W/Ethylene Propylene SealsHigh Radiation Area
Earthquake
ML20084C71216 September 1974Preliminary AO 50-219/74/47:on 740912,two Bergen-Paterson Hydraulic Shock & Sway Arrestor on South Core Spray Sys Found Inoperable.Caused by Component Failure.Two Snubbers Replaced W/Units Rebuilt W/Ep SealsDesign basis earthquake
ML20084C7343 September 1974AO 50-219/74-46:on 740826,one Torus to Drywell Vacuum Breaker Failed to Demonstrate Operability.Caused by Excessive Friction in Valve Hinge Pins.Burring Difficulty Discussed W/Atwood & Morrill Co,Valve Manufacturer
ML20084C75127 August 1974Preliminary AO 50-219/74/46:on 740826,one Torus Drywell Vacuum Breaker Failed to Demonstrate Operability.Caused by Excessive Friction in Valve Hinge Pins.Bushing Difficulty Discussed W/Atwood & Morrill Co,Valve Manufacturer
ML20084C78626 August 1974Preliminary AO 50-219/74/45:on 740824,commitment to Follow MAPLHGR Limits Violated.Caused by Insufficient Guidance. Reactor Power Reduced by Recirculation Flow to Point Where No MAPLHGR Limits Violated
ML20084C80319 August 1974AO 50-219/74-44:on 740809,main Steam Line Low Pressure Switches RE22A,B,C & D Found to Trip at Pressures Less than Min of 860 Psig.Caused by Switch RepeatabilityFuel cladding
ML20084C8489 August 1974Preliminary AO 50-219/74/44:on 740809,main Steam Line Low Pressure Switches RE23A,B,C & D Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability. Setpoint Accuracy Being InvestigatedFuel cladding
ML20084C9132 August 1974Preliminary AO 50-219/74/43:on 740802,main Steam Line Low Pressure Switch RE23B Found to Trip at Pressure Less than Min of 860 Psig.Caused by Switch Repeatability.Set Point Accuracy & Tolerance Being Investigated by GEFuel cladding