Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML20085M63928 November 1973AO BFAO-7343W:on 731118,during Startup Test Program, Significant Vibration Detected in Torus & torus-ring Header When Relief Valves Opened.Torus Support Saddle Feet Will Be Shimmed to Ensure Proper Torus Support
ML20085M64426 November 1973AO BFAO-7341W:on 731116,during Accelerated Surveillance Testing,Reactor Protection Sys Water Level Switches LIS-3-203A,B & C Malfunctioned.Cause Unstated.Switches Reset & New Locking Assembly Installed
ML20085M64718 November 1973Telecopy AO BFAO-7341T:on 731116,during Accelerated Surveillance Testing,Reactor Water Level Switches LIS-3-203A,B & C Operated Outside Tech Specs
ML20085M65123 November 1973AO BFAO-7342W:on 731115 & 16,during Startup Testing,Hpci Suction Valve Aligned to Torus Due to Water Level Functions in Torus.Caused by Release of Reactor Steam from Relief Valves Through Discharge Pipes.Investigation Continuing
ML20085M65223 November 1973AO BFAO-7340W:on 731115,during Accelerated Surveillance Testing,Hpci Steamflow Excessive Pressure Switches PdIS-73-1A & 1B Malfunctioned.Caused by Contacts in Improper Setting.New Locking Plate Assemblies Installed
ML20085M65918 November 1973Telecopy AO BFAO-7340T:on 731115,during Accelerated Surveillance Testing,Hpci Steam Flow Excessive Pressure Switches PdIS-73-1A & 1B Malfunctioned
ML20085M67023 November 1973AO BFAO-7339W:on 731115,during Accelerated Surveillance Testing,Reactor Protection Sys Condenser Low Vacuum Pressure Switch PS-2-1B Malfunctioned.Cause Unstated.Switch Replaced
ML20085M68718 November 1973Telecopy AO BFAO-7339T:on 731115,during Accelerated Surveillance Testing,Turbine Condenser Low Vacuum Pressure Switch PS-2-1B Malfunctioned
ML20085M75123 November 1973AO BFAO-7338W:on 731115,at 25% Power W/Msiv Closed,Rcic & HPCI Sys Failed.Caused by Movable Contact of Dc Contactor Being Hung in Arcing Horn.Contactor RepairedSafe Shutdown
Reactor Vessel Water Level
ML20085M88323 November 1973AO BFAO-7337W:on 731114,during Routine Surveillance,Core Spray Pump Discharge Pressure Switches PS-75-7 & 35 Malfunctioned.Caused by Setpoint Drift.Switches Recalibr
ML20085M89116 November 1973AOs Bf EAO-7349W Through Bf EAO-7352W:on 731108-14,fish Killed When Impinged on Intake Screens.Proposal to Change ETS to End Requirements for Daily Impingement Repts Sent to AEC Directorate of Licensing
ML20085M89521 November 1973AO BFAO-7336W:on 731114,during Hot Standby Condition,Hpci Inverter Power Supply Fuse Failed.Caused by High Voltage Spike During Surveillance Check of Newly Installed 1/4-amp Switches.Spike Suppressor Installed
ML20085M89821 November 1973AO BFAO-7335W:on 731113,during Startup Test Program, Aug 1973 Plant Mod Eliminating High Water Level Initiation of MSIV Closure Found Contrary to Tech Specs.Caused by Procedural Error.Tech Spec Amended
ML20085M90214 November 1973Telecopy AO BFAO-7335T:on 731113,during Hot Standby, Actuation Signal Which Caused MSIVs to Isolate in Startup Mode on High Reactor Water Level Found Deleted from Plant Design But Not from FSAR or Tech Specs
ML20085M92116 November 1973AO BFAO-7333W:on 731108,during Accelerated Surveillance Testing,Reactor Protection Sys Water Level Switches LIS-3-203B & C Malfunctioned.Caused by Setpoint Drift. Switches Recalibr
ML20085M9279 November 1973Telecopy AO BFAO-7333T:on 731108,during Routine Surveillance Testing,Water Level Switches LIS-3-203B & C Operated Outside Tech Specs
ML20085M93110 November 1973Telecopy AO BFAO-7334T:on 731110,condition Discovered Whereby Complete Loss of Plant Electrical Power Would Cause HPCI & RCIC to Be Inoperable Until Manually Reset
ML20085M9439 November 1973AOs Bf EAO-7344W Through Bf EAO-7348W:on 731101-07,fish Killed When Impinged on Intake Screens.Proposal to Change ETS to End Requirements for Daily Impingement Repts Sent to AEC Directorate of Licensing
ML20085N40019 November 1973AO BFAO-7334W:on 731110,during Manual Trip Because of Sudden Increase in Vibration,Rcic & HPCI Sys Inoperable Due to Complete Loss of Plant Ac Electrical Power.Caused by Problem W/Control Logic.Evaluation ContinuingSafe Shutdown