Administration | |
MONTHYEARRS-07-012, Request for Technical Specifications Change for Minimum Critical Power Ratio Safety Limit2007-01-16016 January 2007
[Table View]Request for Technical Specifications Change for Minimum Critical Power Ratio Safety Limit Project stage: Request ML0706700472007-03-19019 March 2007 RAI Cycle 20 Minimum Critical Power Ratio Safety Limit Project stage: RAI ML0711003662007-05-0202 May 2007 Technical Specifications, Issuance of Amendment Request for Technical Specifications Change for Minimum Critical Power Ratio Safety Limit Project stage: Approval ML0711003442007-05-0202 May 2007 License Amendment, Issuance of Amendment Request for Technical Specifications Change for Minimum Critical Power Ratio Safety Limit Project stage: Approval ML0711401932007-05-0303 May 2007 Withholding from Public Disclosure, Addition Information Supporting Request for TSs Change Cycle 20 Minimum Critical Power Ratio Safety Limit Project stage: Other ML0709305112007-05-0303 May 2007 Request for Withholding Information from Public Disclosure for Quad Cities Unit 1 Cycle 20 Minimum Critical Power Ratio Safety Limit Project stage: Withholding Request Acceptance 2007-03-19 |
ML071100366 | |
Person / Time | |
---|---|
Site: | Quad Cities |
Issue date: | 05/02/2007 |
From: | NRC/NRR/ADRO |
To: | |
Williams J, NRR/DORL/LPL3-2, 415-1470 | |
Shared Package | |
ML071100359 | List: |
References | |
TAC MD4008 | |
Download: ML071100366 (1) | |
Similar Documents at Quad Cities | |
---|---|
Category:Technical Specifications
MONTHYEARML23349A1622023-12-17017 December 2023
[Table view]Issuance of Amendment Nos. 298 and 294 Increase Completion Time in Technical Specification 3.8.1.B.4 (Emergency Circumstances) RS-23-080, Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs2023-08-30030 August 2023 Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs ML22217A0442022-12-0707 December 2022 Issuance of Amendment Nos. 292 and 288 Control Rod Scram Times ML22090A0862022-04-29029 April 2022 Amendments to Adopt TSTF-541,Rev.2,Add Exceptions to Surveillance Requirements for Valves,Dampers Locked in Actuated Position RS-22-049, Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for2022-04-0404 April 2022 Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for V RS-22-006, Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel2022-01-20020 January 2022 Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel ML21347A0382022-01-13013 January 2022 Issuance of Amendments to Revise Reactor Coolant Leakage Requirements JAFP-21-0089, Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position2021-09-27027 September 2021 Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position ML21033A5302021-04-0101 April 2021 Issuance of Amendments to Adopt Technical Specifications Task Force TSTF-566, Revise Actions for Inoperable RHR Shutdown Cooling Subsystems ML21013A0052021-02-0404 February 2021 Issuance of Amendments to Adopt Technical Specifications Task Traveler TSTF-568, Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2 RS-20-016, County, Nine Mile Point, Peach Bottom Atomic and Quad Cities - Application to Revise Technical Specifications to Adopt TSTF-566, Revise Actions for Inoperable RHR Shutdown Cooling Systems2020-04-13013 April 2020 County, Nine Mile Point, Peach Bottom Atomic and Quad Cities - Application to Revise Technical Specifications to Adopt TSTF-566, Revise Actions for Inoperable RHR Shutdown Cooling Systems RS-20-046, Emergency License Amendment Request - Increase Technical Specifications Allowable MSIV Leakage Rates in TS 3.6.1.32020-04-0101 April 2020 Emergency License Amendment Request - Increase Technical Specifications Allowable MSIV Leakage Rates in TS 3.6.1.3 RS-18-020, Application to Revise Technical Specifications to Modify the APRM Channel Adjustment Surveillance Requirement2018-06-15015 June 2018 Application to Revise Technical Specifications to Modify the APRM Channel Adjustment Surveillance Requirement ML17311A1622017-12-0101 December 2017 Issuance of Amendments Regarding Permanent Extension of Type a and Type C Leak Rate Test Frequencies ML17298A4422017-10-19019 October 2017 Technical Requirements Manual RS-17-126, Quad Cities Nuclear Power Station, Units 1 & 2, Technical Requirements Manual2017-10-19019 October 2017 Quad Cities Nuclear Power Station, Units 1 & 2, Technical Requirements Manual ML16111A1042016-05-11011 May 2016 Issuance of Amendments to Revise the Reactor Steam Dome Pressure in Technical Specification 2.1.1, Reactor Core SLs (CAC Nos. MF6640-MF6644) RS-16-035, County, and Quad Cities - Request for License Amendment to Address Secondary Containment Access Openings2016-02-0303 February 2016 County, and Quad Cities - Request for License Amendment to Address Secondary Containment Access Openings ML15324A4392015-12-17017 December 2015 Issuance of Amendments (CAC Nos. MF5471-MF5476) ML15268A4862015-10-0606 October 2015 Correction of Amendments Adopting Technical Specification Task Force Traveler TSTF-523 (TAC Nos. MF4436-MF4446) ML15183A3512015-08-0505 August 2015 Issuance of Amendments Concerning Adding Topical References to Technical Specifications (TAC Nos. MF3359, MF3363, MF3361, and MF3362)(RS-13-288) ML15141A0582015-07-28028 July 2015 Issuance of Amendments Regarding Emergency Action Level Schemes (TAC Nos. MF4232-MF4251) ML15106A9472015-04-24024 April 2015 Correction to Amendments Regarding Battery Surveillance Requirements (TAC Nos. MF4589 and MF4590) ML14323A5222015-04-0808 April 2015 Issuance of Amendments Regarding the Emergency Plan Definition of Annual Training ML15056A7722015-03-30030 March 2015 Issuance of Amendments Regarding ML14085A5322014-07-21021 July 2014 Issuance of Amendments Adoption of TSTF-522 Ventilation System Surveillance Requirements RS-13-288, Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report.2013-12-19019 December 2013 Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report. RS-13-137, Application to Revise Technical Specifications to Adopt TSTF-522, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month, Using the Consolidated Line Item Improvement Process2013-09-0303 September 2013 Application to Revise Technical Specifications to Adopt TSTF-522, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month, Using the Consolidated Line Item Improvement Process RS-13-165, Request for License Amendment to Revise Battery Surveillance Requirements2013-06-10010 June 2013 Request for License Amendment to Revise Battery Surveillance Requirements RS-11-180, Quad Cities, Unit 2 - Request for Technical Specification Change for Safety Limit Minimum Critical Power Ratio2011-11-22022 November 2011 Quad Cities, Unit 2 - Request for Technical Specification Change for Safety Limit Minimum Critical Power Ratio ML1132603482011-11-22022 November 2011 Request for Technical Specification Change for Safety Limit Minimum Critical Power Ratio ML0926704882009-10-21021 October 2009 Issuance of Amendments Risk Informed Modification to Selected Required Action End States for BWR Plants RS-09-036, Request for License Amendment to Technical Specification (TS) 3.4.5, RCS Leakage Detection Instrumentation, TS 5.6.5, Core Operating Limits Report (Color), and Renewed Facility Operating License2009-04-0707 April 2009 Request for License Amendment to Technical Specification (TS) 3.4.5, RCS Leakage Detection Instrumentation, TS 5.6.5, Core Operating Limits Report (Color), and Renewed Facility Operating License ML0824703052008-08-28028 August 2008 Technical Specifications, TSTF Change Traveler TSTF-479 & TSTF-497 ML0823907072008-08-21021 August 2008 Revised T.S. Pages Oyster Creek Nuclear Generating Station and Peach Bottom Atomic Power Station, Unit 3-Correction to Facility Operating Licenses ML0821301362008-07-25025 July 2008 Braidwood/Byron/Clinton/Dresden/Lasalle/Oyster Creek/Peach Bottom/Quad Cities/Three Mile Island - Tech Spec Pages for Amds to Change TS Unit Staff Qualifications Education and Experience Eligibility Requirements for Licensed Operators ML0828300312008-07-22022 July 2008 License Amendment, Modify Technical Specification Requirements Related to Turbine Condenser Vacuum - Low Scram Instrumentation Setpoint.-TS Page ML0821105462008-07-22022 July 2008 Technical Specifications, Modifcations Related to Turbine Condenser Vacuum - Low Scram Instrumentation Setpoint RA-08-024, Amergen, Energy LLC, License Amendment Request to Remove References to NRC Generic Letter 82-12, Nuclear Power Plant Staff Working Hours.2008-04-21021 April 2008 Amergen, Energy LLC, License Amendment Request to Remove References to NRC Generic Letter 82-12, Nuclear Power Plant Staff Working Hours. ML0805903842008-03-20020 March 2008 Technical Specifications 5.5, Programs and Manuals, Pages 5 .5-12 Through 5 .5-14, Dresden Units 2 and 3, to CR Habitability Amendment ML0808604742008-03-20020 March 2008 Technical Specifications, Amendment No. 233 and 218 for Dresden and Quad Cities - TS Pages to Dresden/Quad CR Habitability Amendment, 3.7 Plant Systems and 5.5 Programs and Manuals ML0805904092008-03-20020 March 2008 Technical Specifications 3.7, Plant Systems, Pages 3 .7 .4-1 Through 3 .7 .4-3, Dresden Units 2 and 3, to CR Habitability Amendment ML0805903732008-03-20020 March 2008 Technical Specifications 5.5, Programs and Manuals, Pages 5 .5-12 Through 5 .5-14, Dresden Units 2 and 3, to CR Habitability Amendment ML0805903992008-03-20020 March 2008 Technical Specifications 3.7, Plant Systems, Pages 3 .7 .4-1 Through 3 .7 .4-3, Quad Cities Units 1 and 2, to CR Habitability Amendment RS-08-012, Amergen Company, Request for Amendment to Administrative Controls Section of Technical Specifications2008-02-28028 February 2008 Amergen Company, Request for Amendment to Administrative Controls Section of Technical Specifications ML0803100732008-02-28028 February 2008 Technical Specifications, Issuance of Amendments Safety Limit Minimum Critical Power Ratio ML0735400492007-12-19019 December 2007 Letter to C. Pardee Correction of Administrative Error in Amendment - the Consistency of TSs to Exelon Generation Company Quality Assurance TR (Tac. MD3937 Thru MD3940 and MD3943 Thru MD3948). - Rplacement Pages RS-07-157, Request for Technical Specification Change for Minimum Power Ratio Safety Limit2007-11-20020 November 2007 Request for Technical Specification Change for Minimum Power Ratio Safety Limit ML0733310942007-11-19019 November 2007 Tech Specs for Amendments to Provide Consistency with Quality Assurance Topical Report ML0731101022007-11-0101 November 2007 Issuance of Amendments to Increase the Main Steam Safety Valve Lift Setpoint Tolerance and Standby Liquid Control System Enrichment - Tech. Spec. Pages 2023-08-30 |
Text
SLs 2.0 2.0 SAFETY LIMITS (SLs)2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow: THERMAL POWER shall be 25% RTP.2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow: For Unit 1, MCPR shall be 1.11 for two recirculation loop operation or 1.13 for single recirculation loop operation.
For Unit 2, MCPR for GNF fuel shall be > 1.09 for two recirculation loop operation, or > 1.10 for single recirculation loop operation.
MCPR for Westinghouse fuel shall be > 1.11 for two recirculation loop operation, or > 1.13 for single recirculation loop operation.
2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 1345 psig.2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s: 2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.Quad Cities 1 and 2 2.0-1 Amendment No. /226 234