Pages that link to "05000289/LER-2013-001"
Jump to navigation
Jump to search
The following pages link to 05000289/LER-2013-001:
Displayed 50 items.
- 05000289/LER-1982-011, Forwards LER 82-011/99X-0 (← links)
- 05000289/LER-1978-013, Forwards LER 78-013/01T-0 (← links)
- 05000289/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000289/LER-1983-044, Forwards LER 83-044/01T-1.Info Potentially Relevant to Plant Design & Procedures Phase of Proceeding.Svc List Encl (← links)
- 05000289/LER-1995-001, Forwards LER 95-001 Re Rc Leak Caused by Failure of Parker Hannifin Instrument Tube Compression Fitting That Was Found Inadequately Tightened (← links)
- 05000289/LER-1983-046, Revised LER 83-046/01T-1:on 831214,nuclear safety-related Circuit for make-up Pump Lube Oil Pressure Trip Found Incorrectly Routed.Caused by Design Oversight.Circuits for make-up Pumps Rerouted in Raceways (← links)
- 05000289/LER-1983-007, Forwards LER 83-007/03L-0 (← links)
- 05000289/LER-1983-011, Forwards LER 83-011/01T-0 (← links)
- 05000289/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000289/LER-1982-008, Forwards LER 82-008/01T-0 (← links)
- 05000289/LER-1982-001, Updated LER 82-001/01T-2:on 820225,during Control Room Habitability Review of NUREG-0737,Item III.D.3.4,potential Discovered for Contaminated Air to Enter Area Served by Control Bldg Ventilation Sys.Flange Installed (← links)
- 05000289/LER-1983-009, Forwards LER 83-009/03L-0 (← links)
- 05000289/LER-1983-008, Forwards LER 83-008/01T-0 (← links)
- 05000289/LER-1984-004, Forwards Corrected LER 84-004-00 Re Misplugged Steam Generator Tubes.Rept Date Corrected & Licensee Contact Changed (← links)
- 05000289/LER-1977-016, Supplemental LER 77-016/01T:on 770924,emergency Core Cooling Actuation Occurred.Caused by Full Open Pressurizer Power Relief Valve.Valve Closed (← links)
- 05000289/LER-1983-005, Forwards LER 83-005/01T-0 (← links)
- 05000289/LER-1978-008, Forwards LER 78-008/01T-0 (← links)
- 05000289/LER-1983-003, Updated LER 83-003/01T-1:on 830211,PORV Special Insp Revealed Corrosion.Caused by Use of Acid Sulfur Compounds. PORV Internals Replaced & Leak Tested & Pressurizer Steam Space Inspected (← links)
- 05000289/LER-1997-004, Forwards LER 97-004-00 Re Auxiliary & Fuel Handling Bldg Ventilation Sys Declared Inoperable,Due to Questions on Quality Classification on 970228 (← links)
- 05000289/LER-1997-001, Forwards Corrected Copy of LER 97-001-00 Re Condition Found During Review of GL 96-06 (← links)
- 05000289/LER-1997-006, Forwards LER 97-006-00,resulting from Violation of TS 3.3 & Declaring Reactor Bldg fans,AH-E-1B & C,Inoperable on 970424 (← links)
- 05000289/LER-1991-008, Forwards LER 91-008-00 Re Missed Surveillance for Core Flood Tank Samples.Ler Submitted Per Interim Util Policy Issued in Response to Violations Noted in Insp Rept 50-289/92-20 (← links)
- 05000289/LER-1984-007, Corrected LER 84-007-01:on 841116,once-through Steam Generator a Tubes Identified as Category C-3 Defective (More than 1% of Insp Tubes Defective).Further Manifestation of Problem Found During 1981 & 1982 Testing (← links)
- 05000289/LER-1981-013, Forwards LER 81-013/01T-0 Re Leaking Found in Steam Generators.Event Reportable Per Tech Spec 6.9.2.A(3). Supporting Documentation Encl (← links)
- 05000289/LER-1998-010, Forwards LER 98-010-00 Re Potential Violation of Design Criteria During Single Auxiliary Transformer Operation Reported on 980825.Second & Associated Issue Was Identified & Reported on 980916,as Suppl Info IAW 10CFR50.72(c) (← links)
- 05000289/LER-1998-012, Forwards LER 98-012-00 Re CR Damper in Control Bldg Habitability Emergency Ventilation Envelope That Was Discovered Out of Position.Event Did Not Adversely Affect Health & Safety of Public (← links)
- 05000289/LER-1998-009, Forwards LER 98-009-00 Re Potential Loss of HPI During Postulated LOCA with Most Limiting Single Failure.Caused by Misapplication of Design Inputs When Operating Procedures Were Changed Prior to Startup for Current Operating Cy (← links)
- 05000289/LER-1998-008, Forwards LER 98-008-00,re Radiation Monitor RM-A8G-High Which Was Inoperable for More than 7 Days Due to Less than Adequate Performance of Calibr Surveillance (← links)
- 05000289/LER-1997-008, Forwards LER 97-008-00 Re Failure of Four CRs to Meet TS Section 4.7.1.1 Insertion Requirement of 1.66 Seconds on 970621 (← links)
- 05000289/LER-1999-006, Forwards LER 99-006-00,providing Complete Description,Extent of Condition & Actions Taken in Association with Determination of Inability of Pressurizer Support Bolts to Meet FSAR Requirements (← links)
- 05000289/LER-1999-004, Forwards LER 99-004-00,re Discovery of Emergency FW Pump Bearing Failure During Performance of Oil Change on 990510. Event Was Determined Reportable IAW 10CFR50.73,since Pump Was Determined to Be Inoperable Longer than TS AOT (← links)
- 05000289/LER-1997-010, Forwards LER 97-010-00,concerning Inoperable PORV Resulting from Violation of TS 4.2.2,in that,post-maintenance Test Was Not Performed on PORV Following Replacement During 11R Refueling (← links)
- 05000289/LER-1998-011, Forwards LER 98-011-01,which Updates & Replaces Info Re Thermo-Lag Fire Barriers Found Installed Outside Approved Joint Arrangement.Rept Was Determined Reportable on 980825 & Reported Via LER 98-011-00 on 980923 (← links)
- 05000289/LER-1996-002, Forwards LER 96-002-01,updating Status of Corrective Actions & Correcting Inaccurate Date Given for Calculation Referred to in LER Which Was Noted During Insp by NRC Region I (← links)
- 05000289/LER-1998-001, Forwards LER 98-001-00,concerning Flow Instrumentation Allowed to Remain Out of Svc for Greater than 72 H TS Allowable Outage Time.Event Did Not Adversely Affect Health & Safety of Public (← links)
- 05000289/LER-1998-013, Forwards LER 98-013-01 Re Failure to Perform Fire Protection Program Surveillances at Required Frequency.Completed Corrective Actions Described in Section Viii of Attached Rept Constitute Commitments Made to Reduce Occurrence (← links)
- 05000289/LER-1997-007, Forwards LER 97-007-00 Re Loss of Offsite Power Event That Occurred at TMI-1 on 970621 (← links)
- 05000289/LER-1999-001, Forwards LER 99-001-00,re Short Sections of Piping Were Below Temps Specified in FSAR Section 9.2.1.2.LER Is follow-up to Notification Made Via ENS Telephone to NRC on 990122 (← links)
- 05000289/LER-1999-003, Forwards LER 99-003-00, Discovery of Condition Outside UFSAR Design Basis for CR Habitability, Which Was Determined Reportable on 990310.Rept Is Being Submitted Four Weeks Later than Required,Per Discussion with NRC (← links)
- 05000289/LER-1999-008, Forwards LER 99-008-00 Re Discovery of Degraded But Operable Condition of RB Emergency Cooling Sys.Condition Did Not Adversely Affect Health & Safety of Public (← links)
- 05000289/LER-1998-007, Forwards LER 98-007-00, Inoperable Intake Screen & Pump House Floor Drain Check Valves Due to Lack of Preventive Maint & Periodic Insps, Per 10CFR50.73.Rept Was Evaluated & Determined Reportable on 980720.W/o Encl (← links)
- 05000289/LER-1998-005, Forwards LER 98-005-00 Re Inoperable Fire Dampers Determined Reportable on 980416.No New Commitments Made within Ltr (← links)
- 05000289/LER-1998-006, Forwards LER 98-006-00,re Thermo-Lag Fire Barrier That Was Found Installed Outside Approved Joint Design Arrangement (← links)
- 05000289/LER-1998-002, Forwards LER 98-002-01,providing Addl Info Addressing Reason for Event,Extent of Problem Associated W/Missing Operator Aid,Assessment of Safety Consequences of Event & Corrective Actions Taken (← links)
- 05000289/LER-1998-003, Forwards LER 98-003-00 Re 980218 Occurrence Which Was Evaluated & Determined to Be Reportable,Per 10CFR50.73 (← links)
- 05000289/LER-1998-004, Forwards LER 98-004-00,re Condition Where Both Trains of Reactor Building Spray Were Inoperable for Approximately 5 H Due to Installation of Console Switch Pushbutton Assembly (← links)
- 05000289/LER-1999-009, Forwards LER 99-009-00 Re 990626 Event Involving Partial Loss of Offsite Power & Subsequent Automatic Start of EDG 1A.Commitments Made by Util Are Contained in long-term Corrective Actions Section (← links)
- 05000289/LER-1997-003, Forwards LER 97-003-01 Re Potential Overpressurization of Makeup Pump Suction Piping,Due to Inadequate Test & Operating Procedures (← links)
- 05000289/LER-1999-007, Forwards LER 99-007-01 Re Increasing Failure Rate of ESAS Relays.Rept Supplements Preliminary Info Re Determination of Root Cause & Long Term Corrective Actions.Changes Made for Supplement Are Indicated in Bold Typeface (← links)
- 05000289/LER-1997-009, Forwards LER 97-009-00,re Condition Which Was Evaluated & Determined to Be Reportable on 970725.Condition Was Identified as Result of Review of Crystal River 3 LER for Applicability at TMI-1 (← links)