L-PI-05-082, Request for Relief No. 21, for the Plant 3rd 10-Year Interval Inservice Inspection Program: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
 
Line 24: Line 24:
* Welch, Minnesota 55089-9642 Telephone: 651.388.1121
* Welch, Minnesota 55089-9642 Telephone: 651.388.1121


Document Control Desk Page 2 cc:   Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure
Document Control Desk Page 2 cc:
Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure


omtNu Committed to Nu~erxcle Nuclear Management Company, LLC Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East
omtNu Committed to Nu~erxcle Nuclear Management Company, LLC Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East
Line 34: Line 35:
* Welch, Minnesota 55089-9642 Telephone: 651.388.1121
* Welch, Minnesota 55089-9642 Telephone: 651.388.1121


Document Control Desk Page 2 cc:   Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure
Document Control Desk Page 2 cc:
Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure


ENCLOSURE September 2005 ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval This enclosure consists of a 7 page write-up, entitled, 'ISI Relief Request No. 21 (Rev.
ENCLOSURE September 2005 ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval This enclosure consists of a 7 page write-up, entitled, 'ISI Relief Request No. 21 (Rev.
Line 51: Line 53:
* Attachment 12, Prairie Island Procedure SWI NDE-LTS-1, Rev. 1 'Limitations to NDE" 13 pages 78 pages follow
* Attachment 12, Prairie Island Procedure SWI NDE-LTS-1, Rev. 1 'Limitations to NDE" 13 pages 78 pages follow


ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Limited Examination SYSTEM:           Various                                           CLASS: 1 and 2 CATEGORY: Various                                                   ITEM NO: Various Impractical Examination Requirements:
ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Limited Examination SYSTEM:
Various CLASS: 1 and 2 CATEGORY: Various ITEM NO: Various Impractical Examination Requirements:
American Society of Mechanical Engineers (ASME) Section Xl (1989 Edition, no addenda)
American Society of Mechanical Engineers (ASME) Section Xl (1989 Edition, no addenda)
Code requires full examination coverage of inservice inspection (ISI) components per Table IWB-2500-1, and IWC-2500-1. NRC Regulatory Guide 1.147 endorses the use of Section Xl Code Case N-460, "Alternative Examination Coverage for Class 1 and Class 2 Welds." This code case allows greater than 90% coverage of a weld to meet the "essentially 100%"
Code requires full examination coverage of inservice inspection (ISI) components per Table IWB-2500-1, and IWC-2500-1. NRC Regulatory Guide 1.147 endorses the use of Section Xl Code Case N-460, "Alternative Examination Coverage for Class 1 and Class 2 Welds." This code case allows greater than 90% coverage of a weld to meet the "essentially 100%"
Line 60: Line 63:
Basis for Relief:
Basis for Relief:
This request is submitted pursuant to 10 CFR 50.55a(g)(5)(iv) which states, 'Where an examination requirement by the code or addenda is determined to be impractical by the licensee and is not included in the revised inservice inspection program as permitted by paragraph (g)(4) of this section, the basis for this determination must be demonstrated to the satisfaction of the Commission."
This request is submitted pursuant to 10 CFR 50.55a(g)(5)(iv) which states, 'Where an examination requirement by the code or addenda is determined to be impractical by the licensee and is not included in the revised inservice inspection program as permitted by paragraph (g)(4) of this section, the basis for this determination must be demonstrated to the satisfaction of the Commission."
The regulation further states in 10 CFR 50.55a(g)(1) that, "For a boiling or pressurized water-cooled nuclear power facility whose construction permit was issued before January 1, 1971, components (including supports) must meet the requirements of paragraphs (g) (4)and (g)(5) of this section to the extent practical." 10 CFR 50.55a(g)(4) states, "Throughout the service life of a boiling or pressurized water-cooled nuclear power facility, components (including supports) which are classified as ASME Code Class 1, Class 2, and Class 3 must meet the requirements, except design and access provisions and preservice examination requirements, set forth in Section Xl of editions of the ASME Boiler and Pressure Vessel Code ... to the extent practical within the limitations of design, geometry and materials of construction of the components."
The regulation further states in 10 CFR 50.55a(g)(1) that, "For a boiling or pressurized water-cooled nuclear power facility whose construction permit was issued before January 1, 1971, components (including supports) must meet the requirements of paragraphs (g) (4) and (g)(5) of this section to the extent practical." 10 CFR 50.55a(g)(4) states, "Throughout the service life of a boiling or pressurized water-cooled nuclear power facility, components (including supports) which are classified as ASME Code Class 1, Class 2, and Class 3 must meet the requirements, except design and access provisions and preservice examination requirements, set forth in Section Xl of editions of the ASME Boiler and Pressure Vessel Code... to the extent practical within the limitations of design, geometry and materials of construction of the components."
1 of 7
1 of 7


Line 69: Line 72:
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vill, Supplements 4,6 and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vill, Supplements 4,6 and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The following supporting documentation has been provided:
The following supporting documentation has been provided:, ISI Drawing 2-ISI-40, Examination Report Number 2005VE019 and WesDyne report Reactor Vessel (RV) Nozzle (N-10), Outlet Nozzle to Vessel Loop B:
Attachment 1, ISI Drawing 2-ISI-40 Attachment 2, Examination Report Number 2005VE019 and WesDyne report Reactor Vessel (RV) Nozzle (N-10), Outlet Nozzle to Vessel Loop B:
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vil, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vil, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to do outside access and weld configuration.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to do outside access and weld configuration.
The following supporting documentation has been provided:
The following supporting documentation has been provided:, ISI Drawing 2-ISI-40, Examination Report Number 2005VE021 and WesDyne report 2 of 7
Attachment 1, ISI Drawing 2-ISI-40 Attachment 3, Examination Report Number 2005VE021 and WesDyne report 2 of 7


ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Reactor Vessel (RV) Nozzle (N-8), SI Nozzle to Vessel Loop A:
ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Reactor Vessel (RV) Nozzle (N-8), SI Nozzle to Vessel Loop A:
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The examination was limited in both the parallel and perpendicular scans from the vessel IDto 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The following supporting documentation has been provided: , [SI Drawing 2-lSI-40 , Examination Report Number 2005VE023 and WesDyne report Reactor Vessel (RV) Nozzle (N-I1), SI Nozzle to Vessel Loop B:
The following supporting documentation has been provided:, [SI Drawing 2-lSI-40, Examination Report Number 2005VE023 and WesDyne report Reactor Vessel (RV) Nozzle (N-I1), SI Nozzle to Vessel Loop B:
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix ViII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix ViII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.
The examination was limited in both the parallel and perpendicular scans from the vessel IDto 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The examination was limited in both the parallel and perpendicular scans from the vessel ID to 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.
The following supporting documentation has been provided: ISI Drawing ISI-40 , Examination Report Number 2005VE024 and WesDyne report Part B: Category B-F, "Pressure Retaining Dissimilar Metal Welds" Reactor Coolant (RC) Weld (W-5), Nozzle to Safe End:
The following supporting documentation has been provided: ISI Drawing ISI-40, Examination Report Number 2005VE024 and WesDyne report Part B: Category B-F, "Pressure Retaining Dissimilar Metal Welds" Reactor Coolant (RC) Weld (W-5), Nozzle to Safe End:
This dissimilar metal weld joint configuration is not currently covered by the demonstrated samples at the Electric Power Research Institute (EPRI) Perf6rmance Demonstration Initiative (PDI) center. Due to the design of the joint, no mockup could be created to examine this ultrasonically to meet Appendix VIII, Supplement 10.
This dissimilar metal weld joint configuration is not currently covered by the demonstrated samples at the Electric Power Research Institute (EPRI) Perf6rmance Demonstration Initiative (PDI) center. Due to the design of the joint, no mockup could be created to examine this ultrasonically to meet Appendix VIII, Supplement 10.
3 of 7
3 of 7
Line 94: Line 95:
2005P032). No relevant indications were detected.
2005P032). No relevant indications were detected.
The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 619/2005). No leakage was identified in the vicinity of the weld.
The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 619/2005). No leakage was identified in the vicinity of the weld.
The following supporting documentation has been provided: , ISI Drawing 2-lSI-33A , Examination Report Number 2005U036 Part C: Category B-J, "Pressure Retaining Welds in Piping" Residual Heat Removal (RH) Weld (W-11) Valve to Pipe:
The following supporting documentation has been provided:, ISI Drawing 2-lSI-33A, Examination Report Number 2005U036 Part C: Category B-J, "Pressure Retaining Welds in Piping" Residual Heat Removal (RH) Weld (W-11) Valve to Pipe:
This piping weld is subject to be examined by both volumetric and surface examination methods. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplement 2. The examination was conducted using 45 and 60-degree transducers. The valve and piping material are austenitic stainless steel. The examination is limited to 50% in both the axial and circumferential directions from the piping side of the weld due to the weld joint configuration connection to the valve. The credited volumetric examination of the Weld 4 of 7
This piping weld is subject to be examined by both volumetric and surface examination methods. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplement 2. The examination was conducted using 45 and 60-degree transducers. The valve and piping material are austenitic stainless steel. The examination is limited to 50% in both the axial and circumferential directions from the piping side of the weld due to the weld joint configuration connection to the valve. The credited volumetric examination of the Weld 4 of 7


ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2,   3rd Interval Required Volume (WRV) was limited to 47.77% and only a single-sided examination could be performed. It should be noted that the volumetric examination was performed through 100% of the Code WRV; however, the PDI Appendix Vill procedure used is not qualified for the detection of flaws on the far side of single sided access examinations on austenitic stainless steel piping welds. The techniques employed for the examination provide for a best effort examination. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.
ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Required Volume (WRV) was limited to 47.77% and only a single-sided examination could be performed. It should be noted that the volumetric examination was performed through 100% of the Code WRV; however, the PDI Appendix Vill procedure used is not qualified for the detection of flaws on the far side of single sided access examinations on austenitic stainless steel piping welds. The techniques employed for the examination provide for a best effort examination. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.
The required surface examination was performed using liquid penetrant and was not limited. 100% of the required surface area was inspected (Inspection Report No.
The required surface examination was performed using liquid penetrant and was not limited. 100% of the required surface area was inspected (Inspection Report No.
2005P019). No relevant indications were detected.
2005P019). No relevant indications were detected.
The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 6/9/2005). No leakage was identified in the vicinity of the weld.
The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 6/9/2005). No leakage was identified in the vicinity of the weld.
The following supporting documentation has been provided: , ISI Drawing 2-ISI-1 OA , Examination Report Numbers 2005U024 Part D: Category C-F-2 "Pressure Retaining Welds in Carbon or Low Alloy Steel Piping" Main Steam (MS) Weld (W-14), Tee to Flange:
The following supporting documentation has been provided:, ISI Drawing 2-ISI-1 OA, Examination Report Numbers 2005U024 Part D: Category C-F-2 "Pressure Retaining Welds in Carbon or Low Alloy Steel Piping" Main Steam (MS) Weld (W-14), Tee to Flange:
This tee to flange pipe weld is subject to be examined by both volumetric and surface examination methods. The reducer tee and pipe materials are carbon steel. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VilI, Supplement 3. The examination was conducted using 45 and 60-degree transducers. The piping materials are A155 KC70 . The credited volumetric examination of the WRV was limited to 74.85%. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.
This tee to flange pipe weld is subject to be examined by both volumetric and surface examination methods. The reducer tee and pipe materials are carbon steel. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VilI, Supplement 3. The examination was conducted using 45 and 60-degree transducers. The piping materials are A155 KC70. The credited volumetric examination of the WRV was limited to 74.85%. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.
The required surface examination was performed using Dye Penetrant and 95.8% of the required surface area was inspected (Inspection Report No. 2005P043). No relevant indications were detected.
The required surface examination was performed using Dye Penetrant and 95.8% of the required surface area was inspected (Inspection Report No. 2005P043). No relevant indications were detected.
5 of 7
5 of 7


ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval The weld is included in the boundary examined by VT-2 during pressure testing (SP 2168.1 1, completed 9/13/2003). No leakage was identified in the vicinity of the weld.
ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval The weld is included in the boundary examined by VT-2 during pressure testing (SP 2168.1 1, completed 9/13/2003). No leakage was identified in the vicinity of the weld.
The following supporting documentation has been provided:
The following supporting documentation has been provided: 0, ISI Drawing 2-lSI-47B 1, Examination Report Number 2005U023 Additional Means of Establishing Component Integrity:
Attachment 10, ISI Drawing 2-lSI-47B Attachment 11, Examination Report Number 2005U023 Additional Means of Establishing Component Integrity:
System integrity is monitored during normal operation by many direct and indirect methods, e.g., containment radiation monitoring, containment air monitoring, containment sump monitoring, containment temperature monitoring, system walk downs, surveillance testing, etc.
System integrity is monitored during normal operation by many direct and indirect methods, e.g., containment radiation monitoring, containment air monitoring, containment sump monitoring, containment temperature monitoring, system walk downs, surveillance testing, etc.
Alternate Examination:
Alternate Examination:
Line 119: Line 119:
6 of 7
6 of 7


IS[ Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Table 1. Limited Examinations - Prairie Island Unit 2 - 2005 Refueling Outage Comp                     ,Method Io CSYSTEM verage Rep             -,,
IS[ Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Table 1. Limited Examinations - Prairie Island Unit 2 - 2005 Refueling Outage CSYSTEM Comp  
Cate~orpltem'N~.p;;.                 ____      ummary,#j~.sr~inj~~~-~~t¶iait~~                                     ritatlonrt#-':
,Method Io verage Rep ritatlonrt#-':
B-D       83.90           Reactor Vessel     2-ISI-40   N-7     Outlet Nozzle     UT     78.56%     2005VE019       Limited due to 505018   to Vessel Weld                                         configuration.
Cate~orpltem'N~.p;;.
Loop A B-D       B3.90           Reactor Vessel     2-ISI-40   N-10     Outlet Nozzle     UT     78.56%     2005VE021       Limited due to 505020   to Vessel Weld                                         configuration.
ummary,#j~.sr~inj~~~-~~t¶iait~~
    .-                                                              Loop B B-D       B3.90           Reactor Vessel     2-ISI-40   N-8     Si Nozzle to     UT     59.26%     2005VE023       Limited due to 505727     Vessel Weld                                         configuration.
B-D 83.90 Reactor Vessel 2-ISI-40 N-7 Outlet Nozzle UT 78.56%
Loop A B-D       B3.90           Reactor Vessel     2-ISI-40   N-11     SI Nozzle to     UT     59.26%     2005VE024       Limited due to 505726     Vessel Weld                                         configuration.
2005VE019 Limited due to 505018 to Vessel Weld configuration.
_ Loop B B-F       B5.70         Reactor Coolant   2-ISI-33A   W-5       50 degree       UT
Loop A B-D B3.90 Reactor Vessel 2-ISI-40 N-10 Outlet Nozzle UT 78.56%
* 0%     2005U036
2005VE021 Limited due to 505020 to Vessel Weld configuration.
* No Demonstrated 501137       Elbow to               58.84%                 technique at PDI for PI Nozzle                                             configuration B-J       B9.11             Residual Heat   2-lSI-10A   W11     Valve to Pipe     UT     44.77%       2005U024   Single side access Removal                 501953 C-F-2     C5.80             Main Steam     2-lSI-47B   W-14     Tee to Flange     UT     74.85%       2005U023 Flange configuration and 500818                                                   support adjacent to weld 7 of 7
Loop B B-D B3.90 Reactor Vessel 2-ISI-40 N-8 Si Nozzle to UT 59.26%
2005VE023 Limited due to 505727 Vessel Weld configuration.
Loop A B-D B3.90 Reactor Vessel 2-ISI-40 N-11 SI Nozzle to UT 59.26%
2005VE024 Limited due to 505726 Vessel Weld configuration.
_ Loop B B-F B5.70 Reactor Coolant 2-ISI-33A W-5 50 degree UT
* 0%
2005U036
* No Demonstrated 501137 Elbow to 58.84%
technique at PDI for PI Nozzle configuration B-J B9.11 Residual Heat 2-lSI-10A W11 Valve to Pipe UT 44.77%
2005U024 Single side access Removal 501953 C-F-2 C5.80 Main Steam 2-lSI-47B W-14 Tee to Flange UT 74.85%
2005U023 Flange configuration and 500818 support adjacent to weld 7 of 7


                            ,.;i 0 CONT. ON 2-ISI-33C <
,.;i 0
T 2700 =Z no
CONT. ON 2-ISI-33C T 2700 = Z no C
                                                                            . C
/- CONI. ON 4-%I-38_
                                                                            /- CONI . ON   4-%I-38_
X1  
X1     = WELD NO.
= WELD NO.
REF:                        IFILE NO:21040R05 N                                                     /
N  
I                                 CONT. ON 2-ISI-32C   NS5i ( M&SP ) - P 1-2                         12 I REACTOR VESSEL      NOZZLES    DWN: DMN     CHKD:       Q,     APPD:
/
SYSTEM:REACTOR VESSEL NOZZLES 0                                                      LINE: NA DWG:           2-ISI-40                   REV: 06
I CONT. ON 2-ISI-32C REACTOR VESSEL NOZZLES REF:
IFILE NO:21040R05 NS5i
( M&SP ) - P 1 -2 1 2 I DWN: DMN CHKD:
Q, APPD:
SYSTEM:REACTOR VESSEL NOZZLES LINE: NA DWG:
2-ISI-40 REV: 06 0


NM7ij'                                             Ultrasonic Examination Site/Unit: -
NM7ij' Ultrasonic Examination Site/Unit:
PINGP   /     P12                   Procedure:           UT-Vendor             Outage No.:       E031 Summary No.:                505018                  Procedure Rev.:                0                Report No.:     2005VE019 Workscope:                  'SI                    Work Order No.:            0406670                  Page:     1     of   5 Code:               1989 Edition             Cat./Iltem:       B-D/B3.90         Location:
Summary No.:
Drawing No.:                   2-ISI-40                  
Workscope:
PINGP /
P12 505018 Procedure:
Procedure Rev.:
Work Order No.:
UT-Vendor 0
0406670 Outage No.:
E031 Report No.:
2005VE019 Page:
1 of 5
'SI Code:
1989 Edition Cat./Iltem:
B-D/B3.90 Location:
Drawing No.:
2-ISI-40  


== Description:==
==
Outlet Nozzle to Vessel Weld Loop A System ID:         RV Component ID: N-7                                                   Size/Length:       NA           Thickness/Diameter:     9.17"153" Limitations:       See WesDyne exam report Comments:
Description:==
Outlet Nozzle to Vessel Weld Loop A System ID:
RV Component ID: N-7 Size/Length:
NA Thickness/Diameter:
9.17"153" Limitations:
See WesDyne exam report Comments:
See supplements and Refer to the applicable WesDyne report found in the book:
See supplements and Refer to the applicable WesDyne report found in the book:
Prairie Island Nuclear Power Plant I Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
Prairie Island Nuclear Power Plant I Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
  ^ 78.56%, See WesDyne final report Results:             NAD   E         IND i           GEO E]           Indications allowable by Code Percent Of Coverage Obtained > 90%:                 No                 Reviewed Previous Data:           Yes Examiner       Level li               Signature                 Date Reviewer                         Ig Signature                 Date VENDOR, WESDYNE                                           5/15/2005 Jones, Thomas           ,      _
^ 78.56%, See WesDyne final report Results:
Examiner       Level N/A             Signature                 Date Site Review                         Signature} ,. r     Date N/A                                                                 Wren, Jerry P       5,i Other         Level N/A             Signature                 Date ANII Review                         Signature               Date N/A                                                                   Daly, Gerald                                           tek)6*E
NAD E IND i GEO E]
Indications allowable by Code Percent Of Coverage Obtained > 90%:
No Reviewed Previous Data:
Yes Examiner Level li Signature Date Reviewer Ig Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas Examiner Level N/A Signature Date Site Review Signature},.
r Date N/A Wren, Jerry P 5,i Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald tek)6*E


Supplemental Report NM ')                                                                                                                                                                     Report No.:               2005VE019 Page:         2       of   5 Summary No.: 505018 Examiner: VENDOR, WESDYNE                                                     Level:       II         Reviewer Jones, Thomas                                       CPZJ1-        -      Date:       ____
NM ')
Examiner:        NIA                                                          Level:      N/A       Site Review: Wren, Jerry P                                                           Date:    5 ' .vij Other: NIA                                                              Level:     N/A       ANII Review: Daly, Gerald                                                             Date: ISALrr,cS Comments:
Supplemental Report Report No.:
Sketch or Photo: J:MlSIData]SIPI2_05 outage\Scans\WeDyne Vessel Flaws\505018 N-7\Flaw Sizing 1.bmp ISI Flaw Sizing Worksheet Procedure:     tLX'rST-                 ;z-;/-       A/z           Outage No.:        J&deg; rZ,      F,2c  '
2005VE019 Page:
Summary No.:            .50C S- Of/            9                            ProCcdura Rev.:                           0                               Report No.:        -76DS1VE        O 19 WorkScope:                _.zS -7                                          Work Order No.:             ! 5                         70                         Page:                of
2 of 5
: 1) Flaw Number          _                                                3) ISI Interval                         _        g_ _       _    _              k*    OK Reviewer
Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner:
: 2) Itemt    Number              8      3a,  90                            4) Code Edition & Addenda                   j 9ff           /.   ,                  W OK Reviewer
NIA Other:
: 5) Method                                               _      -r-                   *t    01< Reviewer C) Flaw Sketch (See Selow)                                                           k)   OK Revlc.er               '
NIA Level:
Flaw Vtow
II Reviewer Jones, Thomas Level:
                                                                                                                                                                      -
N/A Site Review: Wren, Jerry P Level:
* Ja I                                           /1.-n                                                                       />
N/A ANII Review: Daly, Gerald CPZJ1-Date:
I    //     17..                 V q      =,      SC
Date:
: 7) Calculations               -  OK Reviewer Show determination of Surface onC                         i         S Show determination of                 oI     D   to use
5 '.vij Date: ISALrr,cS Comments:
: 8) Hit .
Sketch or Photo: J:MlSIData]SIPI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\Flaw Sizing 1.bmp Summary No.:
FE   Pnrngraph---                                 ta   .. t-     Was used             M   Yes         PreparerC                                         Reviewer        5
.50C S-Of
: 9) Code Frtaw Dimensions                 4g OK Reviewer                                                                                                                     --  ,    j/S
/ 9 WorkScope:
                  -  . IS             -    o ,       -.        t nomnr--                 9 . :.   'I nmeasured"           -
_.z S -7 ISI Flaw Sizing Worksheet
: 10) Flow Typn                       9                     OK Reviewer                     _          S   b   --                    =.    -    5--
: 1) Flaw Number
I 1) Flaw Characterization Figure                   tt     OK Reviewer                             :2Z..--' A   -    5   3-2.4
: 2) Itemt Number 8
: 12) Flaw Characterization Figure Number                                           z   /
3a, 90 Flaw Vtow Procedure:
: 13) Was IWA-3300 Flaw Characterization followed?                                       0D Yes     0   No       If no. why?
tLX'rST-  
: 14) The correct Code Edition and Addenda was available and usexd.                                     g)   Yes           Prepoaer-.           erLi. J       C9 OK Reviewer
;z-;/-
___                    52~     /~             ___                  _____                      ___I 1 5)             n     d     d             -                                                          16) Rl               b       nd,                   ,          -2o-'
A/z ProCcdura Rev.:
The results are correct and the methodology used Is in accordance                                     The rev             assures that the results are correct and the with applicable codes, standards. specilications and procedures.                                       methodology used Is In accordance with applicable codes.
0 Work Order No.:  
! 5 70
: 3) ISI Interval g_ _
: 4) Code Edition & Addenda j 9ff  
/.
: 5) Method  
-r-C) Flaw Sketch (See Selow)
Outage No.:
J&deg; rZ, F,2c Report No.:
-76DS1VE O 19 Page:
of k* OK Reviewer W OK Reviewer
*t 01< Reviewer k)
OK Revlc.er
* Ja q
=,
SC/>
I  
/1.-n I
//
17..
V
: 7) Calculations OK Reviewer Show determination of Surface onC i
S Show determination of oI D
to use
: 8)
Hit FE Pnrngraph---
ta  
.. t-Was used M Yes PreparerC
: 9) Code Frtaw Dimensions 4g OK Reviewer
. IS o,
t nomnr--
9. :.  
'I nmeasured"
: 10) Flow Typn 9
OK Reviewer S
b I 1) Flaw Characterization Figure tt OK Reviewer
:2Z..--' A 5
3-2.4
: 12) Flaw Characterization Figure Number z  
/
: 13) Was IWA-3300 Flaw Characterization followed?
0D Yes 0
No If no. why?
=.
5--
Reviewer 5
j/S
: 14) The correct Code Edition and Addenda was available and usexd.
g)
Yes Prepoaer-.
erLi.
J C9 OK Reviewer 52~  
/~
___I 1 5) n d
d
: 16) Rl b
nd,  
-2o-'
The results are correct and the methodology used Is in accordance The rev assures that the results are correct and the with applicable codes, standards. specilications and procedures.
methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
AdditlOnAl - tSI fr       uSize   Odt   rfon, Set-up-Additional - Supplemental Reports <edit from Setup>
AdditlOnAl - tSI fr uSize Odt rfon, Set-up-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                                                        Report No.:                     2005VE019 Page:               3       of       5 Summary No.: 505018 Examiner: VENDOR, WESDYNE                                                                        Level:                 II           Reviewer, Jones, Thomas                                         C__    _ _,_ _            Date:     _ _ _ _ _ _ _
NM)
Examiner: N/A                                                                                    Level:              N/A         Site Review: Wren, Jerry P                                                   '- -            Date:      ,-        -'--s Other: NIA                                                                                Level:               N/A         ANII Review: Daly, Gerald                                         ion                         Date:         t'A t6&
Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner:
N/A Other: NIA Supplemental Report Report No.:
2005VE019 Page:
3 of 5
Level:
II Reviewer, Jones, Thomas Level:
N/A Site Review: Wren, Jerry P Level:
N/A ANII Review: Daly, Gerald C_
Date: _ _ _ _ _ _ _
Date:
-'--s ion Date:
t'A t6&
U)
U)
Comments:
Comments:
Sketch or Photo: J;\lSIDataJSIxp12_05 outage\Scans\WeDyne Vessel Flaws\505018 N-7\Flaw Disposition 1.bmp ISI Flaw Disposition Worksheet ilntUnit:             ,P?           I                                                               Procedure:       Ptr .s--               Z5"/-A/Z                         Outage No.:          Pr2
Sketch or Photo: J;\\lSIDataJSIxp12_05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\Flaw Disposition 1.bmp ilntUnit:  
* ig Summary          No.:              35    0        O      1,                                          Procedure Rev.:                         C>                                         Report No.:            cS        -J,    c      9 Worhscope:                                                                                        Work Order No.:               O L/ 0       (,a CD 7       &deg;                               Page:                      of
,P?
: 1) Flew Number                  _                                                          3) IS;1 interval                                         -                                          ED    OK Reviewer                  C;4 1  zJ
I Summary No.:
: 2)  Itemn Number                      B. 3      . q eD                                  4) C, ode EdItlon & Addenda                           /98 9 -          .'/o C, 4.P.               4OK          Reviewer              $a-i
35 0
: 5) At .Ceptanlce Standard                             . B           -   5 S/       A,               6b OK Reviewer
O 1,
: 6) Calculations (See Below)                                                                          (!     OK Reviewer                   P f'
Worhscope:
                      -9 "''6"--I                   :
ISI Flaw Disposition Worksheet Procedure:
C        =,0. ?                                                   =       S9-2a VS/e '%> =                       /0 "q-
Ptr.s--
              &#x17d;' = !S/--                             e)       O   -7       l9../                       =A                 1           C.,         /-   0
Z5"/-A/Z Procedure Rev.:
: 7) Restilts             Q     OK Reviewer ctl/-         ., /33             Code       allowable alt"6                           2 <                  Calculated       WIt%                           Laminar flaw             surface     area:   (0.75     I   w)   -
C>
A)   Table       used   for   analysis                 6F       OK       Reviewer                   tt                               3     S ,            'e 2..,
Work Order No.:
: 0)   Was     lbnonr Interpolation               used7                   CD     Yes           (0       No         If no. why?
O L/ 0 (,a CD 7  
4CL I- 6& 10/8     P7          Z- 4C                        -45                #r&+c                       r2/                         ,3S' IO)   Was       IWA-3200           Significant         Digits         For     l.lmiting     Values         followed?             417 Yes           O     No         If no. why?
&deg;
: 11) The     correct     Code       Edition       and     Addenda               was     available           and   used.           (P   Yes       Preparnr--t_.i                   J         O     OK   Reviewer
;1 interval ode EdItlon & Addenda  
: 12) Statemcnt           or   acceptability           or   rejectability             with   basis.                   1OK  Reviewer                                   0p(J O   Accept             0   Reject CO   (all)   Code       allowable         a   (alt)       calculated C)     OEM     [law     evaluation           handbook               (see     attached         analysis)
/98 9  
C)     (sit)   Code     allowable         <  (Cel)       calculated
.'/o C, 4.P.
: 13)   Prepared       by   .nd     patc                                                 r14ngineering                                                     r         w   bA   arid   date The   rosults     are     correct       and     the   fnethodology                 used     Is     In accordance             Ths1-reiiew       assures         that   the     results     are   correct     and     tIhe with     applicable       codes.         standards.         specifications               and         procedures.               methodology         used     Is   in   accordance           with   applicable         codes.
.Ceptanlce Standard B  
                                                                                                          /                               stanstau.,u     speciaion                 a81,0 procvedurer.
- 5 S/
: 15) Acproved byandSato This approval assures that all Inrvfived with Jhis flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standards. specifications and procedures.
A, Outage No.:
Addrtiorl - Isl Flow                               .edil ROcspvriiinf rr       Setrup, Additional - Supplemental Reports <edit frtom Setup>
Pr2 ig Report No.:
cS
-J, c
9 Page:
of ED OK Reviewer C;4 1 zJ 4OK Reviewer
$a-i 6b OK Reviewer
(!
OK Reviewer P f'
: 1) Flew Number
: 2) Itemn Number B. 3
. q eD
: 3) IS
: 4) C,
: 5) At
-9 "''6"--I C
=,0. ?
: 6) Calculations (See Below)
=
S9-2a VS/e '%> =  
/0 "q-
&#x17d;' = !S/--
e)
O -7 l9../  
=A 1
C.,  
/-
0
: 7) Restilts Q
OK Reviewer ctl/ -
., /33 Code allowable alt"6 2
Calculated WIt%
Laminar flaw surface area: (0.75 I
w)
A) Table used for analysis 6F OK Reviewer tt 3
S 2..,
e
: 0)
Was lbnonr Interpolation used7 CD Yes (0
No If no.
why?
4CL P
I-6& 10/8 7
#r&+c r2/
Z-4C
,3S'  
-45 IO)
Was IWA-3200 Significant Digits For l.lmiting Values followed?
417 Yes O
No If no.
why?
: 11) The correct Code Edition and Addenda was available and used.
(P Yes Preparnr--t_.i J
O OK Reviewer
: 12) Statemcnt or acceptability or rejectability with basis.
1 OK Reviewer 0p(J O
Accept 0
Reject CO (all)
Code allowable a (alt) calculated C)
OEM
[law evaluation handbook (see attached analysis)
C)
(sit)
Code allowable (Cel) calculated
: 13)
Prepared by.nd patc r14ngineering r
w bA arid date The rosults are correct and the fnethodology used Is In accordance Ths1-reiiew assures that the results are correct and tIhe with applicable codes.
standards.
specifications and procedures.
methodology used Is in accordance with applicable codes.
/
stanstau.,u speciaion a81,0 procvedurer.
: 15) Acproved by andSato This approval assures that all Inrvfived with Jhis flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standards. specifications and procedures.
Addrtiorl - Isl Flow ROcspvriiin
.edil f rr
: Setrup, Additional - Supplemental Reports <edit frtom Setup>


Supplemental Report NM)                                                                                                                                                                      Report No.:               2005VE019 Page:         4       of     5 Summary No.: 505018 Examiner: VENDOR, WESDYNE                                                       Level:         II           Reviewer: Jones, Thomas .                         CiM                       Date:        _____
NM)
Examiner: NIA                                                                    Level:        N/A        Site Review: Wren, Jerry P                                   97-                 Date:     8f-ca s Other: NIA                                                                Level:        NIA      ANIll Review: Daly,            , . GeraldA                                        Date:     1       b 1   P--
Supplemental Report Report No.:
2005VE019 Page:
4 of 5
Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:
II Level:
N/A Si Level:
NIA AN Reviewer: Jones, Thomas. CiM te Review: Wren, Jerry P 97-Ill Review: Daly, GeraldA Date:
Date:
8f -ca s Date: 1 b
1 P--
Comments:
Comments:
Sketch or Photo: J:\lslDatalSRPl2-05 outage\Scans\WeDyne Vessel Flaws\'505018 N-7AFlaw Sizing 2.bmp NM             ~>                   __              _                ISI Flaw Sizing Worksheet
Sketch or Photo: J:\\lslDatalSRPl2-05 outage\\Scans\\WeDyne Vessel Flaws\\'505018 N-7AFlaw Sizing 2.bmp NM  
:13 Site/Unit:         P         /I       C                                         Procedure:        Pb7-iST-                            AZ OVZ/-      Outage No.:          PzAie            eSS Summary No.:                 50 5=0 t S3                                           Procedure Rev.:                                                       Report No.:           ;.?o 0-S* VECi Workasope:                 :rs                                                  Work Order No.:                 9                   -70                         Page:                of
~>
: 1) Flaw Number              _                _          _                  3)   tSI Interval                           _            -_A-
Site/Unit:
_                      dP    OK Reviewer
P  
: 2) Item Number                      a      E,    g0                          4) Code Edition & Addenda                     / 9W         -. 4,                     ) OK Reviower
/ I C
: 5) Method                                                 &#xa3;-4 L.-  e/          p        /AJ-                                          6) Flaw Sketch (See Below)                                                         0     OK Reviewer                 _
Summary No.:
Flaw View
50 5=0 t S3 Workasope:
_4 qi 2 9               ..
:rs
                                                                                                                                                                        ,, q c,,                           b csN I       I
: 1) Flaw Number
                                                                                                          *-.      C 4- ONr
: 2) Item Number a
: 7) Calculations                 Q@4OK Raviewer                 :8K         -
E, g0 L.- e/
Show determilirnution         or   Surface or Stibsurface Show   detcrminallon       r     Itpor      a,   to tose SJI - A1,6 -6           -        7 .2L           *--S.~.
p
_d C> .r       -t;     _. e.-
/AJ-Flaw View ISI Flaw Sizing Worksheet Procedure: Pb7-iST-OVZ/-
0)44     FE-   Paragraph7-               _    .  !              t.           was used               @Yes           Preparr371_               J       Q@ OK Reviewer
AZ Procedure Rev.:
: 9) Code Flaw Diiesiorns                       (M OK Reviewer
Work Order No.:
                    -I0                   a -       0.1         't   no'nmnnl       -   -               't   measured                       -            s   -   /     V   , -w -    -
9  
: 10) Flaw Type                           r1OK                         Reviewer       P          S     b                       .--        e t 1)   Flaw Charactcrlzation Figure                   CO OK Reviewer                               2   3 S .          -                    -/
-70
: 12) Flaw Charactorizntion Figure Number                                                       /
: 3) tSI Interval  
: 13) Was IWA-3300 Flaw Characterization fotlowed?                                           @Yes         0     No     If no. why?
-_A-
: 14) The correct Codo Ed lion and Addenda was available and used.                                                       VYos      Preparer-        I t    Jk          @JOK      Reviewer
: 4) Code Edition & Addenda  
: 15) Pr!!pareg           and datol                                                             /             16)   R:           e~       da         Ae  L 4               v   .'                    f.-
/ 9W  
The results are correct and the methodology used is in accordance                                            The rev           assures that the results are correct and the with applicable codes. standards. spocificntlons and procedures.                                              methodology used Is in accordaice with applicable codes, standards, specifications and procedures.
-. 4,
Additional - ISa Fl.-       S.z. .ed.t     fro,   Seltp.
: 5) Method  
&#xa3;-4
: 6) Flaw Sketch (See Below)
:13 Outage No.:
PzAie eSS Report No.:
;.?o 0-S* VE Ci Page:
of dP OK Reviewer
) OK Reviower 0
OK Reviewer q i
_4 2 9
,, q c,,
b csN I I C 4-ON r
: 7) Calculations Q@4 OK Raviewer
:8K Show determilirnution or Surface or Stibsurface Show detcrminallon r
I tpor a,
to tose SJI - A1,6 -6 7.2L  
*--S.~.
_d C>  
.r  
-t;
_. e.-
0)44 FE-Paragraph7-
: t.
was used  
@ Yes Preparr371_
J Q@ OK Reviewer
: 9) Code Flaw Diiesiorns (M OK Reviewer
-I0 a -
0.1  
't no'nmnnl - -
't measured s -
/
V  
-w
: 10) Flaw Type r1OK Reviewer S b e
P t 1)
Flaw Charactcrlzation Figure CO OK Reviewer 2
3 S  
-/
: 12) Flaw Charactorizntion Figure Number  
/
: 13) Was IWA-3300 Flaw Characterization fotlowed?  
@ Yes 0
No If no. why?
: 14) The correct Codo Ed lion and Addenda was available and used.
: 15) Pr!!pareg and datol  
/
The results are correct and the methodology used is in accordance with applicable codes. standards. spocificntlons and procedures.
VYos Preparer-t I
Jk
@J OK Reviewer
: 16) R:
e~
da e
4 A
v L
f.-
The rev assures that the results are correct and the methodology used Is in accordaice with applicable codes, standards, specifications and procedures.
Additional - ISa Fl.- S.z..ed.t fro, Seltp.
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMl)                                                                                                                                                                              Report No.:       2005VE019 Page:     5       of     5 Summary No.: 505018 Examiner: VENDOR, WESDYNE                                                             Level:           II         Reviewer: Jones, Thomas                                 CV4, 5            Date:      41_/_    5 Examiner: N/A                                                                        Level:         N/A       Site Review: Wren, Jerry P                                                   Date: ,-ec+/-'o Other: NIA                                                                    Level:        NIA      ANII Review: Daly, Gerald                                            =     _ Date:     tiAU&65 Comments:
NMl)
Sketch or Photo: J:\lSIDataJSI\PI2 05 outage\Scans\WeDyne Vessel Flaws\505018 N-7\law Disposition 2.bmp ISI Flaw Disposition Worksheet NMio Site/Unit.         P Zr         I       fi                                         Procedure:            -Xs5-              2ZS-Z                    Outage No.:    rZ2      ? Zz7 Sunirnary No:                 C>         _ O     I   8                             Procedure Rev.:                         O                                 Report No.:            VcY15 L'    0    9 Workscope:                                                                    Work Order No.:               O L       O Co Co 7 0                                 Page:         or
Supplemental Report Report No.:
: 1) Flaw Nuinber                         -            _                      3) ISI Interval
2005VE019 Page:
* OK Reviewer      52fJ
5 of 5
: 2) lIn&     Numnber               B1.       .q I                               4) Code Edition & Addenda                     /F8 9               "ale'   40a.           N OK Reviewer     e~sXkJ S) Acceptance Standard                                                                  I   OK Reviewer     Z tAr z            til      ^_ -                                        6) Catculullons (See          eolo-)                                                    4   OK Reviewer         ;_-
Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner: N/A Other: NIA Level:
ai     - 09     / 0                                     `    =            9                R         =     6../                                           ve-r          60.      /)/0f
II Reviewer: Jones, Thomas Level:
              -9/,P=- . /o                                               vl-'~                     /.     0 y   =                   -/       /. q       , /,     I 0           =.0
N/A Site Review: Wren, Jerry P Level:
: 7) Rrcs.ulls             0 OK Reviewer                   C;t) rnt   -     D9. /0           Code ellowable eWt% -                       .    -      ~       Calculated     tJY._     /   09               Laminar flaw tsurface area: (0.75 1 w) *
NIA ANII Review: Daly, Gerald CV4, 5 Date:
          /)   Table used for onalystn                     -        OK Revilwer                                     ZD_e -       i    3 -, 5   _t     -2j
41_/_
: 0) Was linear interpolation usod?                               C) Yes           0   No       If no. why?
5 Date:,-ec+/-'o
A-uo 7                       "?e .2 c,               l &=
=
: 10) Was IWA-3200 Significant Digits For Limiting Values followod?                                                 0 Yes             C)   No         Ifrno. why?
_ Date:
1t) The correct Code Edition and Addenda was available and used.                                                       Yes         Preparer                     7       O0  OK Reviewer
tiAU&65 Comments:
: 12) Statement or auceptability or rojoctobility with basis.                                       D   OK Reviewer             "        -'            (0' Accept       C)   Reject 1I   (aft) Codo atlowahle >             (WIt)     calculated
Sketch or Photo:
                *i     OEM   flaw   evaluation,         handbook         (see   attached       analysis)
J:\\lSIDataJSI\\PI2 05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\law Disposition 2.bmp NMio Site/Unit.
C)     (a/1) Code       llowoable * (a0t)           calculated 13J                   by annd       o                                                                                                                             date Thle rjlsulls are correct and the methodology used Is In accordance                                         Yhis     v l'ew         sStres that the results are correct and the with applicable codes, standards. specifications and procedures.                                              meth odology used is in accordance with applIcable codes.
P Zr I
fi Sunirnary No:
C>
_ O I 8 Workscope:
ISI Flaw Disposition Worksheet Procedure:
-Xs5-2ZS-Z Procedure Rev.:
O Work Order No.:
O L O Co Co 7 0 Outage No.:
rZ2
? Zz7 Report No.:
VcY15 L'
0 9
Page:
or
: 1) Flaw Nuinber
: 2) lIn& Numnber B
: 1.  
. q I tAr z til
^_ -
: 3) ISI Interval
: 4) Code Edition & Addenda S) Acceptance Standard
: 6) Catculullons (See eolo-)
/F8 9 "ale' 40a.
* OK Reviewer 52fJ N
OK Reviewer e~sXkJ I
OK Reviewer Z
4 OK Reviewer ai 09  
/ 0 R  
=
6../
-9/,P=-. /o
` =
9 ve-r
: 60.
/)/0f vl-'~  
/.
0 y  
=  
-/  
/.
q  
, /,
I 0  
=.0
: 7) Rrcs.ulls 0 OK Reviewer C;t) rnt -
D9. /0 Code ellowable eWt% -
~
Calculated tJ Y._ /
09 Laminar flaw tsurface area: (0.75 1 w) *
/) Table used for onalystn OK Revilwer ZD _e -
3 5
i
_t j
-2
: 0) Was linear interpolation usod?
C) Yes 0
No If no. why?
A-uo 7  
"?e.2 c, l &=
: 10) Was IWA-3200 Significant Digits For Limiting Values followod?
0 Yes C)
No Ifrno. why?
1t) The correct Code Edition and Addenda was available and used.
Yes Preparer 7
0 O
OK Reviewer
: 12) Statement or auceptability or rojoctobility with basis.
D OK Reviewer (0' Accept C) Reject 1I (aft) Codo atlowahle > (WIt) calculated
*i OEM flaw evaluation, handbook (see attached analysis)
C)
(a/1)
Code llowoable * (a0t) calculated 13J by annd o
Thle rjlsulls are correct and the methodology used Is In accordance with applicable codes, standards. specifications and procedures.
date Yhis l'ew v
sStres that the results are correct and the meth odology used is in accordance with applIcable codes.
standards. specifications nnd procedures.
standards. specifications nnd procedures.
: 15) Ap!v=d             by t                     d\   v  d             ale   f This approval assures that all lsr0tved                         witA thlis navw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with                                 Vippilcable codes. standards, specifications and procedures.
: 15) Ap!v=d by t d\\
Adieonel - ISI Flow D09position .edit from                     Selup-Additional - Supplemental Reports <edit from Setup>
d ale f
v This approval assures that all lsr0tved witA thlis navw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with Vippilcable codes. standards, specifications and procedures.
Adieonel - ISI Flow D09position.edit from Selup-Additional - Supplemental Reports <edit from Setup>


REACTOR VESSEL WELD RESULTS  
REACTOR VESSEL WELD RESULTS  


==SUMMARY==
==SUMMARY==
 
PLANT NAME Prairie Island Unit 2
PLANT NAME                 Prairie Island           Unit                         2 WELD NO.               N7 (505018)       COMPONENT               Outlet Nozzle to Shell @ 28.50 LIMITATIONS:       NO F-1                 YES     3j             78.56 % Complete See Coverage Breakdown Sheet RESULTS                                     NO. OF INDICATIONS           2 NI                                       STATUS             Code Allowable RI     X EXAM DOCUMENTATION                     INDICATION DOCUMENTATION Lf PARAGON ANALYSIS LOG                             IEIASSESSMENT SHEET FxII PARAGON ACQUISITION LOG                         mK PARAGON HARD COPY EKI SCAN PRINT OUT                                   =II OTHER (Specify)
WELD NO.
N7 (505018)
COMPONENT Outlet Nozzle to Shell @ 28.50 LIMITATIONS:
NO F-1 YES 3j 78.56 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 2
NI STATUS Code Allowable RI X
EXAM DOCUMENTATION INDICATION DOCUMENTATION Lf PARAGON ANALYSIS LOG IEIASSESSMENT SHEET FxII PARAGON ACQUISITION LOG mK PARAGON HARD COPY EKI SCAN PRINT OUT  
=II OTHER (Specify)
ELl COVERAGE BREAKDOWN Comments:
ELl COVERAGE BREAKDOWN Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
Analyst //,                   Date:   e
Analyst //,
Date:
e


R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME                     Prairie Island WesDyne WELD NO.                         N7 (505018)
R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.
International COMPONENT             Outlet Nozzle to Shell @ 28.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION       l       45 Shear     l     45 L Single           45 L Dual   l Combined Bore/Star
N7 (505018)
_WELD I VOLUME. WELD I VOLUMEj WELD I VOLUME] WELD I VOLUME TAN Scan         l           l______
International COMPONENT Outlet Nozzle to Shell @ 28.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION l 45 Shear l
Parallel           54.33       28.52   64.28       56.90     71.82     69.79   __
45 L Single 45 L Dual l Combined Bore/Star
Combined Bore&Star             l l   Perpendicular                 l         l       60.Il        l                    99.68     99.35 AVERAGE                   41.42               60.59               70.80               99.52 Comments:       Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.                                 I Combined Perp.          99.52     fAX     Combined Para.             57.61         Combined Average         78.56 Analyst          /            /                                                  Date   _//
_ WELD I VOLUME.
1_7    /
WELD I VOLUMEj WELD I VOLUME] WELD I VOLUME TAN Scan l
l______
Parallel 54.33 28.52 64.28 56.90 71.82 69.79 Combined Bore&Star l
l Perpendicular Il l
l
: 60.
99.68 l
99.35 AVERAGE 41.42 60.59 70.80 99.52 Comments:
Combined Perp.
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
I 99.52 fAX Combined Para.
Analyst
/
/
1_7
/
57.61 Combined Average 78.56 Date
_//


                                                  /
/
                                                /             /
/
                                              /             /
/
                                /                       /        6'
/
                            /         /                 /     6'
/
                                    /
/
(9.18)                             /               /     6' WALL                                      /
6'
                                            /
/
                                                      /
/
/
/
6'
/
(9.18)
WALL
/
/
6'
/
1/
1/
                                        <6       //             R66.00 to CIO.I
/
                            /
/
                          //
<6  
                      //
//
                            //
/
                          //           X
//
                                //
//
Transdlucer Sled x                 Package X~/'
//
Figure 1                       26.53 Tar Coverae Illustration Primary Uuttet Nozzle Protrusion Limitation
//
X
//
R66.00 to Transdlucer CIO.I Sled x
Package X~/'
Figure 1 26.53 Tar Coverae Illustration Primary Uuttet Nozzle Protrusion Limitation


Ultrasonic Examination NM -
NM -
Site/Unit:   PINGP     /       P12                    Procedure:          UT-Vendor            Outage No.:        E031 Summary No.:                   5t)5020                 Procedure Rev.:                 0               Report No.:   2005VE021 Workscope:                      IS'                  Work Order No.:             0406670                  Page:   I   of   7 Code:               1989 Edition               Cat./ltem:       B-DIB3.90         Location:
Site/Unit:
Drawing No.:                   2-ISI-40                    
PINGP  
/
Summary No.:
5t Workscope:
Ultrasonic Examination P12
)5020 Procedure:
Procedure Rev.:
Work Order No.:
UT-Vendor 0
0406670 Outage No.:
E031 Report No.:
2005VE021 Page:
I of 7
IS' Code:
1989 Edition Cat./ltem:
B-DIB3.90 Location:
Drawing No.:
2-ISI-40  


== Description:==
==
Outlet Nozzle to Vessel Weld Loop B System ID:         RV Component ID: N-10                                                     Size/Length:       NA           Thickness/Diameter     9.1r153" Limitations:       See WesDyne exam report Comments:
Description:==
Outlet Nozzle to Vessel Weld Loop B System ID:
RV Component ID: N-10 Size/Length:
NA Thickness/Diameter 9.1r153" Limitations:
See WesDyne exam report Comments:
See supplements and Refer to the applicable WesDyne report found in the book:
See supplements and Refer to the applicable WesDyne report found in the book:
Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
  &78.56%, See Wesdyne final report for details.
&78.56%, See Wesdyne final report for details.
Results:             NAD   D]           IND R           GEO   D         Indicaitons allowable by Code Percent Of Coverage Obtained > 90%:                   'No                 Reviewed Previous Data:           NJA Examiner       Level II                 Signature                 Date Reviewer                           (Signature             Date VENDOR, WESDYNE                                             5/15/2005 Jones, Thomas           /         Jo2df Examiner       Level II                 Signature                 Date Site Review                         Signature             Date Auer, Robert G.                                                         Wren, Jerry P                                     "g-e-os Other         Level NIA                 Signature                 Date ANII Review
Results:
* Signature             Date N/A                                                                     Daly, Gerald       .         7 eIQ.                sSo0r     .
NAD D]
IND R GEO D Indicaitons allowable by Code Percent Of Coverage Obtained > 90%:  
'No Reviewed Previous Data:
NJA Examiner Level II Signature Date Reviewer (Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas  
/  
..Jo2df Examiner Level II Signature Date Site Review Signature Date Auer, Robert G.
Wren, Jerry P "g-e-os Other Level NIA Signature Date ANII Review Signature Date N/A Daly, Gerald 7eIQ.
sSo0r.


Supplemental Report NM)                                                                                                                                                              Report No.:             2005VE021 Page:         2     of     7 Summary No.: 505020 Examiner: VENDOR, WESDYNE                                               Level:           II         Reviewer: Jones, Thomas                             C_  _    _  _        Date:         _S ____
NM)
Examiner: Auer, Robert G.                                                Level:            II       Site Review: Wren, Jerry P                                 q               Date:     &#xa3; --       7S Other: NIA                                                        Level:          NIA        ANII Review: Daly, Gerald                                    &Q               Date:     1&4 I)
Supplemental Report Report No.:
2005VE021 Page:
2 of 7
Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.
Other:
NIA Level:
II Reviewer: Jones, Thomas Level:
II Site Review: Wren, Jerry P Level:
NIA ANII Review: Daly, Gerald C_ _
Date:
_S ____
q Date: &#xa3; --
7S
&Q Date: 1&4 I )
Comments:
Comments:
Sketch or Photo: J:ISIData\lSl\PI2_05 outage\Scans\WeDyne Vessel Flaws\50502O N-10\Flaw Sizing 1.bmp i
Sketch or Photo: J:ISIData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\50502O N-10\\Flaw Sizing 1.bmp Site/Unit:
i ISI Flaw Sizing Worksheet I
P1>  
Site/Unit:     P1>       ,J                                               Procedure:     2br-l.ri- ;tS4/                       &.2 7  Outlao      No.:          IZ~  Of              I Stimniary No.:        S O S C          _0 O                            Procedure Rev.:                       0                             Report No.:        .7O0S,    V C  O;/
, J Stimniary No.:
WorksCoPO:            7  SX                                          Work   Order No-           e                   ,I-    o&deg;                     Page:              of i
S O S C
: 1) Flaw Number                     /                               3) ISI Interval                                  -&  _R-                          9    OK Reviewer
_0 O WorksCoPO:
: 2) Itein Number             2           3. 9   o                   4) Code Edition a Addenda                   / 7           ./,     Xi. 1      0    OK Reviewer
7 SX ISI Flaw Sizing Worksheet Procedure: 2br-l.ri- ;tS4/  
: 5)   Method                               _        _"        -_
&.2 Procedure Rev.:
0 Work Order No-e  
-,I o &deg;
: 1) Flaw Number  
/
: 2) Itein Number 2
: 3. 9 o
: 3) ISI Interval
_R-
: 4) Code Edition a Addenda  
/ 7  
./,
Xi.
: 5) Method
: 6) Flaw Sketch (See Below)
: 6) Flaw Sketch (See Below)
* OK Reviewer
Flaw View
                                    ,A-       -    /   C Flaw View
,A-  
                                                                                                                                                            -,       = d9     nO
/
: 7) Calculations           4D OK Reviewer Show dctlrmninalion of Surface or                 bs       3 Show ,latcrrnination   or type of         a to use
C 7
                                          '  '-        j        f-       *- A   C-   Z-I a)ftlr-E.-4 Paragraph-7-d             _R   .--          ft t           was used             tP) Yes     Preparer                       A        OK Reviewer              C
Outlao No.:
: 0) Codu Flaw     Oimonsionrs           W   OK Reviewer
IZ~
                  -    I  3           - 0         0       I nom'nnai-             c. 7       -t measurei       -d                         -s-  o-                w-    Al
O f Report No.:
: 10) Flaw Typo                                     Q OK Reviewer                       5b                    -7er L          PI-,_
.7O0S, V C O;/
: 11) Flaw Characterization Figure                 W OK Reviewer                                   .-  4 -   5         -Cnr - /
Page:
: 12) Flaw Charactoriznlton Figure Number                                       a     I
of 9
: 13) Was IWA-3300 Flaw Characterization followed?                                 SW Yes       0   No   It no. why?
OK Reviewer 1
: 14) The correct Code Edition and Addenda was available end used.                                     0WYes      Preparer             r10                   OK Reviewer t S _                                             /     v       S         16),   ~       dcz.My~
0 OK Reviewer OK Reviewer
and d                             LA,-v The results are correct and the methodology used is In accordance                                 The re4         ssures that the results are correct and the with applicable codos. standards. specifications and procedures.                                   methodology used Is In accordance With applicable codes.
= d9 n O i
i I
I i
: 7) Calculations 4D OK Reviewer Show dctlrmninalion of Surface or bs 3
Show,latcrrnination or type of a
to use j
f-  
* - A C - Z-I a)ftl r-E.-4 Paragraph-7-d
_R ft t was used tP) Yes Preparer
: 0) Codu Flaw Oimonsionrs W OK Reviewer I
3 0
0 I nom'nnai-
: c.
7  
-t measurei  
-d
: 10) Flaw Typo Q OK Reviewer 5 b
-7er
: 11) Flaw Characterization Figure W OK Reviewer 4 -
5  
-C
: 12) Flaw Charactoriznlton Figure Number a
I
: 13) Was IWA-3300 Flaw Characterization followed?
SW Yes 0 No It no. why?
A OK Reviewer C
L
-s-o-
w-Al PI-,_
nr -
/
: 14) The correct Code Edition and Addenda was available end used.
0W Yes Preparer r10 OK Reviewer t S _  
/
v S
16), ~
dcz.My~
and d LA,-v The results are correct and the methodology used is In accordance The re4 ssures that the results are correct and the with applicable codos. standards. specifications and procedures.
methodology used Is In accordance With applicable codes.
standards. speclfications and procedures.
standards. speclfications and procedures.
A"idt.Or,0
A"idt.Or,0
* ISI Flaw SizE *eddt     Imron Setoup Additional - Supplemental Reports <edit from Setup>
* ISI Flaw SizE *eddt Imron Setoup Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                Report No.:       2005VE021 Page:     3       of     7 Summary No.: 505020 Examiner: VENDOR,WESDYNE                                        Level:       _I             Reviewer: Jones, Thomas                       c-jrt,    1      Date: _______
NM)
Examiner: Auer, Robert G.                                        Level:        _1         Site Review: Wren, Jerry P                                         Date: g-5 -;S Other: N/A                                                Level:       N/A         ANII Review: Daly, Gerald                               4           Date:     IsAiydg-(U Comments:
Summary No.: 505020 Examiner: VENDOR,WESDYNE Examiner: Auer, Robert G.
Sketch or Photo: J.ISIDataUSI\P12_05 outagelScanslWeDyne Vessel Flaws\505020 N-101Flaw Disposition 1.bmp ISI Flaw Disposition Workshect NME>
Other: N/A Supplemental Report Report No.:
Site/Unit:     P Z: '        %Z                                 Procedure:     P         xs4r- 2 s5f-z                     Outage No.:  /2 Z-:Z g2        0s-Summary No.:          50 S0 A 0                                    Procedure Rev.:                   O                             Report No.: V2rs* ViE      P    /
2005VE021 Page:
Worksrope:              :                                      Work Order No.:           0) '-O CDeg 7 0                             Page:          ofd  _
3 of 7
: 1) Flaw Number                  /                          3) ISI Interval                                       -.                      es OK Reviewer
Level:
: 2) Item Number          Ei    .q    0                    4) Code Edition & Addenda                 /,98 9         ^/,P     470,
_I Reviewer: Jones, Thomas Level:
* OK Reviewer
_1 Site Review: Wren, Jerry P Level:
: 5) Acceptance Standard                             g-     $   5'/ *;>         4C OK Reviewer uae0,        H-    AJ      JX -                    6) Calculations (See Below)                                                   6R   OK Reviewer a   =4o Oe, VIe=      9-2..),
N/A ANII Review: Daly, Gerald c-jrt, 1
J=/,
Date: _______
            -/1,         t' 0 7-7 LtS-       -      /-     O
Date: g-5 -;S 4
: 7) Results       Q   OK Reviewer DA -       . 0 77     Code allowable avtY       -  2,1. LeJ-     Calculatede/t/%       -  1 C)7           Leaminarflawsurface area:(0.75 I       w)-     .AJ'4
Date:
: 8) Table used for analysis             l;   OK Reviewer           j     -        =Z,   r3 _- 3.s-5 I   -  /
IsAiydg-(U Comments:
: 9) Was linear Interpolation used?             0   Yes         a   No     If no. why?
Sketch or Photo: J.ISIDataUSI\\P12_05 outagelScanslWeDyne Vessel Flaws\\505020 N-101Flaw Disposition 1.bmp NME>
10)a W             ii           gceit foLmi            a Z          -lu ed         /e                   o         f no 2 IO) Was IWA-3200 Significant Digits For Limit ng Values followed?                         4D Yes         O:: No         It no. why?
Site/Unit:
I11) The correct Code Edition and Addenda was available and used.                               PYes       Preparer-.,_,..J               > OK Reviewer 5hW       _
P Z:  
: 12) Statement or acceptability or rejectability with basis.                 0     OK Reviewer                           (<     Accept   Q Reject
%Z Summary No.:
              *  (a/t) Code allowable o (a/t) calculated 0   OEM flaw evaluation handbook (see attached analysis) 0   (a/J) Code allowable       (aft) calculated
50 S0 A 0 Worksrope:
: 13) Prepared by and Oate                                                                     14,ngtneeing re                     y anddt The results are correct and the methodology used Is In accordance                         Thisyeview assures that the results are correct and the with applicable codes. standards, specifications and procedures.                         methodology used Is In accordance with applicable codes.
ISI Flaw Disposition Workshect
: 1) Flaw Number
/
: 2) Item Number Ei
. q 0
: uae0, H-AJ X -
J Procedure: P xs4r-2 s5f-z Procedure Rev.:
O Work Order No.:
: 0) '-O CDeg 7 0
: 3) ISI Interval
: 4) Code Edition & Addenda  
/,98 9  
^/,P 470,
: 5) Acceptance Standard g-  
$ 5'/ *;>
: 6) Calculations (See Below)
Outage No.:
/2Z-:Z g2 0s-Report No.:
V2rs* ViE P
/
Page:
d of es OK Reviewer OK Reviewer 4C OK Reviewer 6R OK Reviewer a  
=4o Oe, J=/,
-/1, t' 0 7-7 VIe= 9-2..),
LtS-  
/-
O
: 7) Results Q
OK Reviewer DA -
. 0 77 Code allowable avtY 2,1.
LeJ-Calculatede/t/%
1 C)7 Leaminarflawsurface area:(0.75 I w)-  
.AJ'4
: 8) Table used for analysis l;
OK Reviewer j  
=Z, r3 _- 3.s-5 I  
/
: 9) Was linear Interpolation used?
0 Yes a
No If no. why?
10)a W
ii gceit fo Lmi Z
a  
-lu ed  
/e o
f no 2 IO) Was IWA-3200 Significant Digits For Limit ng Values followed?
4D Yes O:: No It no. why?
I11) The correct Code Edition and Addenda was available and used.
PYes Preparer-.,_,..J  
> OK Reviewer 5hW
: 12) Statement or acceptability or rejectability with basis.
0 OK Reviewer
( <
Accept Q Reject (a/t) Code allowable o (a/t) calculated 0
OEM flaw evaluation handbook (see attached analysis) 0 (a/J) Code allowable (aft) calculated
: 13) Prepared by and Oate 14,ngtneeing re y anddt The results are correct and the methodology used Is In accordance Thisyeview assures that the results are correct and the with applicable codes. standards, specifications and procedures.
methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
IS) Apwvedby         ary date This approval assures that ail Involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct end In accordance with applicable codes. standards. specifications and procedures.
IS) Apwvedby ary date This approval assures that ail Involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct end In accordance with applicable codes. standards. specifications and procedures.
Additional -11S Flaw Disposilion -edit from Setup-Additional - Supplemental Reports <edit from Setup>
Additional -11S Flaw Disposilion -edit from Setup-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMC)                                                                                                                                                                                              Report No.:           2005VE021 Page:         4       of     7 Summary No.: 505020 Examiner: VENDOR, WESDYNE                                                                       Level:         II             Reviewer: Jones, Thomas                                       C< 9              Date:_____
NMC)
Examiner: Auer, Robert G.                                                                      Level:          II       Site Review: Wren, Jerry P                                                             Date: S-r-c-Other: N/A                                                                                Level:       N/A       ANII Review: Daly, Gerald                                             dQ()             Date: Ls5Afo.6 U
Supplemental Report Report No.:
2005VE021 Page:
4 of 7
Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.
Other: N/A Level:
II Reviewer: Jones, Thomas Level:
II Site Review: Wren, Jerry P Level:
N/A ANII Review: Daly, Gerald C< 9 Date:_____
Date: S-r-c-dQ()
Date:
Ls5Afo.6 U
Comments:
Comments:
Sketch or Photo: J:\ISIData\ISl\PI2_05 outage\Scans\WeDyne Vessel Flaws\505020 N-10\Flaw Sizing 2.bmp tSI Flaw Sizing Worksheet                                                                                                                  I i
Sketch or Photo: J:\\ISIData\\ISl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Sizing 2.bmp Site/Unit:
Site/Unit:         P Z       I       .2_                                                 Procedure:         lebr'-'           S-     f'/-           A/Z       Outage No.:        PXZ R f;S oC      /  I Summary No.;                    &#xa3;54              0p      )  &deg;                                  Procedure Rev.:                                 0                               Report No.:        .OOS    VC Workscope:                              :Z S                                                Work Order No.:                   ::2                 6     ?7 0                       Page:              of i
P Z
: 1)    Flaw      Number                        a_        _            _                      3) tSI intervat                                         S       =5                         O  OK Reviewer
I  
: 2) Item Nurrmber                      a          ;.      9?O                                4) Code Edition & Addenda                           / 9q'V           .r.. 412 0           @    OK Reviewer
.2_
: 5) Method                                                       1<J T JA          Ie/)-e          Al-JO                                                  O) Flow Sketch (See Below)                                                                   @ OK Reviewer Flaw Viow 3.z   /        &?,
Summary No.;
                                                                                                                                                                                                        >O.- tL o                                                                                                                                                                                                                      >0.
&#xa3;54 0 p
I O..
) &deg; Workscope:
                                                                                                                                                                                          .3/           > .tI(A4(.
:Z S
                                                                                                            .z$-Z5
tSI Flaw Sizing Worksheet
                                                                                                        --~1:
: 1)
Flaw Number a_
: 2) Item Nurrmber a
9?O JA Ie/)-e Al-J O Flaw Viow Procedure:
lebr'-'
S-f'/-
A/Z Procedure Rev.:
0 Work Order No.:
::2 6  
?7 0
: 3) tSI intervat S  
=5
: 4) Code Edition & Addenda  
/ 9q'V r..
412 0
: 5) Method 1<J T O) Flow Sketch (See Below)
Outage No.: PXZ R f;S Report No.:
.OOS VC oC
/
Page:
of O
OK Reviewer
@ OK Reviewer
@ OK Reviewer 3.z  
>O.- L t
>0.
O..
/
&?, o.3/  
>.tI(A4(.
3 n -
>.t sb4cf I
i I
i I
-- ~1:.z$-Z5
?
, O./,,-
I I
I
I
                                                                              ?
: 7)
I
Calc,,lilions 0
                                                                                                    ,  O./,,-                I 3n-          > .t              sb4cf
OK Reviewer
: 7)   Calc,,lilions                 0       OK Reviewer
.Show determination or Surface Show determination or type of a to use J.57t~?5
                  .Show determination or Surface Show determination or type of a                           to use
.5i-l - A.6 eO 7: Z s.-
                                        -    J.57t~?5
: 8) 44 rE  
            .5i-     l - A.6 eO         -,      7: Z             s.-*            .-                          .- '
. Paragrapla--
: 8) 44         rE     . Paragrapla--           -                                              was used                 MD Yes            Prep aror            7s4t. J      4S    OK Revlewer                  '~---
was used
: 9) Code Flaw Dimensions                             e     OK Reviewer
: 9) Code Flaw Dimensions e
                  -I-         r           *a     -  _      . 0S5t       nominarl               -        _
OK Reviewer
9    Z   -t   fnwosurvd              -              /            -s- -    3.. ZS    w- -    (
-I-r  
: 10) Flaw Type                                                     (RD OK Reviewer                   7                       s      b ----              l_ cen            P Ir-^e
*a 0S5t nominarl 9
: 1)   Vieaw Characterizaion Figuro                             6C   OK Reviewer .                                       .S    s        --    S    a            -/
Z  
I 2)   Flaw Characterization Figure Number                                                       :ch /
-t
: 13) Was IWA-3300 Flaw Characterization followed?                                                         0   Yes         O   No       If no, why?
: 10) Flaw Type (RD OK Reviewer 7
: 14) The correct Code Edition and Addenda was available end used.                                                               o   Yes           Preparer         (,..Jr              C   OK Reviewer
: 1) Vieaw Characterizaion Figuro 6C OK Reviewer.
                                                                                                              '                      16)   Re                       nd                       _ ,__    =7'           6  -rZ f -    5-I  r,    Pr      a    dbyaddae                                                                              O 5 The results are correct and the methodology used Is in accordance                                                            The revt             &#xa3;t'assurcs that the results are correct and the with nppllcable codos. standards. specifications and procedures.                                                              methodology used Is In accordance with applicable codes.
I 2) Flaw Characterization Figure Number
:ch /
: 13) Was IWA-3300 Flaw Characterization followed?
0 Yes MD Yes Prep aror 7s4t. J 4S OK Revlewer
'~---
fnwosurvd
/
-s- -
3..
Z S w- -
(
s b ----
l_ cen P Ir-^e
.S s
S a
-/
O No If no, why?
: 14) The correct Code Edition and Addenda was available end used.
I r, Pr a
dbyaddae O 5 The results are correct and the methodology used Is in accordance with nppllcable codos. standards. specifications and procedures.
o Yes Preparer r
(,..J C
OK Reviewer
: 16) Re nd  
=7'  
-rZ 6
f 5-The revt  
&#xa3;t'assurcs that the results are correct and the methodology used Is In accordance with applicable codes.
standards, specifications and procedures.
standards, specifications and procedures.
Arddional . ISI Flaw Size *edil from Setupc Additional - Supplemental Reports <edit from Setup>
Arddional. ISI Flaw Size *edil from Setupc Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                Report No.:         2005VE021 Page:         5     of     7 Summary No.: 505020 Examiner: VENDOR, WESDYNE                                                     Level:       II           Reviewer: Jones, Thomas                             c      )        Date:   _/_/o__
NM)
Examiner: Auer, Robert G.                                                      Level:        II       Site Review: Wren, Jerry P                                 Cate:ate:
Supplemental Report Report No.:
                                                                                                                                                                        &Dat:                8-Other: NIA                                                                Level:      NIA       ANII Review: Daly, Gerald                                 ,kW .           Date: ijs-*       L.d (2
2005VE021 Page:
5 of 7
Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.
Other: NIA Level:
II Reviewer: Jones, Thomas Level:
II Site Review: Wren, Jerry P Level:
NIA ANII Review: Daly, Gerald c
)
Date:
_/_/o__
Cate:ate:
8-
&Dat:
,kW.
Date: ijs-*
L.d (2
Comments:
Comments:
Sketch or Photo: J:UlSIData\lSl\PI2_05 outage\Scans\WeDyne Vessel Flaws\505020 N-10\Flaw Disposition 2.bmp ISI Flaw Disposition Worksheat Ni\MeT>
Sketch or Photo: J:UlSIData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Disposition 2.bmp Ni\\MeT>
Site/Unit:         P     X725/         >_                                   Procedure:       P. t-.r5r-                     -A/.Z       Outage No.:     Px>2   g<zS Summary No.:                  7>          -o      a  >,                      Procedure Rev.:                      C                                Report No.:     ;20S   -Vc'   g%   /
Site/Unit:
Workscope:                      _-25  S=                                Work Order No.:              OL. O 6 C(,          7  0                        Page:             of
P X725 /
: 1) Flaw Number                                                           3)11S  interval                      __ ____                                      @0OK  Reviewer C;2o
Summary No.:
: 2) Item, Number                                                         4) Code Edition     & Addenda           / 98 9           IVO X.19       .     4  Ol< Reviewer
7>  
: 5) Acceptance Standard                   .Z'. V       -    3S        ;t         <if  OK Revlewer      IC  _
-o a
: 0) Calculations (Sue Bol-w)                                                       OM OK Reviewer =
Workscope:
j      =        / , L7                                 V K>>   /-                 ~           &            O         ~             D
_- 25 S=
: 7) Results           0     OK Reviewer nA -     O. 033             Code allowable aWt% -               . 0   4-     Calculated anY.       -  D               Laminar (law tsurfoce area: (0.75 1           w)
ISI Flaw Disposition Worksheat Procedure: P. t-.r5r-  
: 0) Toble used for analysis                         P   OK Reviewer             C               .Z       - 3 S '7     -,
-A/.Z Procedure Rev.:
: 9) Was linear Interpolation used?                           CD Yes         0' No       If no, why?
C Work Order No.:
ACz   ' c.e   ,-    71 -     6   C'     0el     -_  C2 /e     O   IOr       7--c 1O) Wes IWA-3200 Significant Digits For Urniting Values followed?                                         O Yes         0   No       If no. why?
OL.
: 11) The correct Code Edition and Addenda was evailable end used.                                           O Yes       Preperer         7-Z     J     9 OK Reviewer
6 O
: 12) Statement of acceptability or rejectabifity with basis.                           l     OK Reviewer                           (1np Accept       C> Reject C     (a/t) Code allowable               (a/lt) calculated
(, C 7 0 Outage No.:
              &deg;D OEM flaw evaluation handbook (see attached analysis)
Px>2 g<zS Report No.:  
C) (sl/) Code allowable (a/I) calculated~
;20S  
: 13) Prepared by and             ate                                                                     IS                rng r                    d date                    '*s The results are correct and the methodology used is In accordance                                     This         w assures that the results are correct and the with applicable codes. standards. specifications and procedures.                                        methodology used is In accordance with applicable codes.
-Vc' g%  
/
Page:
of
: 1) Flaw Number
: 2) Item, Number C;2o 3)11S interval
: 4) Code Edition & Addenda  
/ 98 9 IVO X.19.
: 5) Acceptance Standard  
.Z'. V S
3
;t
: 0) Calculations (Sue Bol-w)
@0 OK Reviewer 4
Ol< Reviewer
<if OK Revlewer IC OM OK Reviewer j
=  
/, L7 V
t
=
K>>  
/-
D
~
O  
~
: 7) Results 0
OK Reviewer nA -
O. 033 Code allowable aWt% -
0 4-Calculated anY.
D Laminar (law tsurfoce area: (0.75 1 w)
: 0) Toble used for analysis P
OK Reviewer C  
.Z  
- 3 S '7
: 9) Was linear Interpolation used?
CD Yes 0' No If no, why?
ACz c
'.e 71 -
6 C'
0el C2 /e O
IOr 7--c 1O) Wes IWA-3200 Significant Digits For Urniting Values followed?
O Yes 0
No If no. why?
: 11) The correct Code Edition and Addenda was evailable end used.
O Yes Preperer 7-Z J
9 OK Reviewer
: 12) Statement of acceptability or rejectabifity with basis.
l OK Reviewer (1np Accept C> Reject C
(a/t) Code allowable (a/lt) calculated
&deg;D OEM flaw evaluation handbook (see attached analysis)
C)
(sl/) Code allowable ~ (a/I) calculated
: 13) Prepared by and ate The results are correct and the methodology used is In accordance with applicable codes. standards. specifications and procedures.
IS rng r d date
'*s This w assures that the results are correct and the methodology used is In accordance with applicable codes.
standards. speciacantlons and procedures.
standards. speciacantlons and procedures.
1S)   Arrv     d hyad       date                     __
1S)
5.9 =...'to                 -,          I This approval assures that alffinvolved with this flaw sizing and ttaw disposition were aware of the necessity thai the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.
Arrv d hyad date 5.9 =...'to I
This approval assures that alffinvolved with this flaw sizing and ttaw disposition were aware of the necessity thai the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.
Add-lional - ISI Flaw DOspositton -edit fromi Setup-Additional - Supplemental Reports <edit from Setup>
Add-lional - ISI Flaw DOspositton -edit fromi Setup-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMC)                                                                                                                                                                    Report No.:                   2005VE021 Page:             6         of     7 Summary No.: 505020 Examiner: VENDOR, WESDYNE                                                          Level:         II        Reviewer: Jones, Thomas                                 &deg;                         Date:   _______
NMC)
Examiner Auer, Robert G.                                                          Level:        II      Site Review: Wren, Jerry P                                   !                ~ Date:       _-2-;
Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner Auer, Robert G.
Other: NIA                                                                  Level:    N/A        ANII Review: Daly, Gerald                                     4M                     Date:       S5&
Other: NIA Supplemental Report Report No.:
2005VE021 Page:
6 of 7
Level:
II Level:
II Level:
N/A Reviewer: Jones, Thomas  
&deg; Date: _______
Site Review: Wren, Jerry P  
~ Date: _-2-;
ANII Review: Daly, Gerald 4M Date:
S5&
LI Comments:
LI Comments:
Sketch or Photo: J:ISIData\ISI\PI205 outage\Scans\WeDyne Vessel Flaws\505020 N-10\Flaw Sizing 3.bmp ISI Flaw Sizing Worksheet Site/Unit.       P             /   .,?.                                     Proceduro:      ?r  -_Sf-r            -            &,Z    Outage      No.:        P              F Surrmary No.:                 5 O s                  LC.)                       Procedure Rev.:                             a                        Report No.:               tO&C      Vt        )   /
Sketch or Photo:
Workscope.                   :r S-L                                        Work Order No.:               O     e4     6         i7&deg;                     Page:                    of
J:ISIData\\ISI\\PI205 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Sizing 3.bmp Site/Unit.
: 1) Fiow Number                            3                                  3) 1St Interval                                   3   -                        CY    OK Reviowor
P  
        ?1  Item Number                      E3      a. 9g0                        4) Code Edition & Addenda                   / 9 I         AC     14Q.           (O    OK Reviewer
/  
: 5) Method                                             L   `-
.,?.
Flaw    e/                  J-lo                                      6) Flaw Sketch (See Below)                                                     <      OK Revitewer                >,
Surrmary No.:
Flavv   View I
5 s
o -             Y-         a')('
O LC.)
I 11' I                                                                                    C2     -
Workscope.
0   ,0
:r S-L
                                                                                                                                                                                                -jo
: 1) Fiow Number 3
___J __,_ -=_                                                                                                                     n  ,/0 4V-
?1 Item Number E3 a.
: 7) Caklculwlio,,                   (>     OK Rovicv..nr Show dolormination of Surface or.                         ubsur Show determination of                     ot   'a'   to use
9g0 ISI Flaw Sizing Worksheet Proceduro:  
            %''      -Ad~e->-essz         <-,      7_                               # i54.       --
?r  
8)i-     FE 4   Preagraph..r--                     .      _ _I l lthoJ     was used             6    Yes      Preparer -                      op- OK Reviewer
-_Sf-r
: 9) Code Flaw Oimonsions                         4D OK Reviewer                   r
&,Z Procedure Rev.:
                  . I S             a   -      10 l            t nonwno       --          22     -t nmees,,e'd        -    .    /Li            -s- -        '5=
a Work Order No.:
: 10)     -law Type                                         R     OK Reviewer <           i-           s        b        _-          eC        Pl,_,
O e4 6
: 11) Flaw Charricterization Figure                           Q9   OK Reviewer         y         _                4- 3 3z                  _,-
i7&deg;
: 12) Flaw Characterization Figure Number                                                     /
: 3) 1St Interval 3
: 13) Was IWA-3300 Flaw Characterization followed?                                         O     Yes     0     No     If no. why?
: 4) Code Edition & Addenda  
: 14) The correct Codo Edition and Addenda was available end used.                                           m   Yes         Preparer         7               tY   OK ReviOwerK                     i     i 1 5)    Prer        by rid 1          e= :nd-                                                 6 9-         17 1 he results are correct and the methodology used Is In accordance                                        The rik         , assures that the results are correct and the with applicable codes, standards, specifications and procedures.                                          methodology used Is In accordance with applicable codes.
/ 9 I AC 14Q.
: 5) Method L  
`-
: 6) Flaw Sketch (See Below)
Flaw e/
Flavv View J-lo Outage No.:
P F
Report No.:
tO&C Vt
)
/
Page:
of CY OK Reviowor (O
OK Reviewer OK Revitewer o -
Y-a')('
C2  
,0 4V-n
,/0 0 -jo I
I 11' I
___J __,_ -=_
: 7) Caklculwlio,,
(>
OK Rovicv..nr Show dolormination of Surface or.
ubsur Show determination of ot  
'a' to use
-Ad~e->-essz 7_  
# i54.
8)i-FE 4 Preagraph..r--
_ _I l lthoJ was used
: 9) Code Flaw Oimonsions 4D OK Reviewer r.
I S
a l
10 t nonwno 22  
-t
: 10) -law Type R
OK Reviewer <
i-
: 11) Flaw Charricterization Figure Q9 OK Reviewer y
: 12) Flaw Characterization Figure Number  
/
: 13) Was IWA-3300 Flaw Characterization followed?
O Yes 6
Yes Preparer -
op-nmees,,e'd
/Li
-s- -
s b
eC Pl,_,
4-3 3z _,-
OK Reviewer
'5=
0 No If no. why?
: 14) The correct Codo Edition and Addenda was available end used.
1 5) Prer by rid 1 he results are correct and the methodology used Is In accordance with applicable codes, standards, specifications and procedures.
AXICI4,nal - 131 Fl-Size.e4i froan, setup.
m Yes Preparer 7
tY OK ReviOwerK i
i 1
e= :nd-17 6 9-The rik  
, assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
AXICI4,nal - 131Fl-        Size .e4i        froan, setup.
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                      Report No.:         2005VE021 Page:       7       of     7 Summary No.: 505020 Examiner: VENDOR, WESDYNE                                                    Level:         II         Reviewer: Jones, Thomas                                         aT.k
NM)
(         Date:   __5_o_     _
Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.
Examiner: Auer, Robert G.                                                    Level:       _1       Site Review: Wren, Jerry P                                                     Date:         S'-'
Other: NIA Supplemental Report Report No.:
Other: NIA                                                              Level:    N/A       ANII Review: Daly, Gerald                                                       Date:     ,sr U
2005VE021 Page:
7 of 7
Level:
II Reviewer: Jones, Thomas aT.k
(
Date: __5_o_
Date:
S'-'
Level:
_1 Site Review: Wren, Jerry P Level:
N/A ANII Review: Daly, Gerald Date:,sr U
Comments:
Comments:
Sketch or Photo: J:IlSlDataliSflP2o05 outageIScanslWeDyne Vessel FlawssO5502O N-10FIaw Disposition 3.bmp ISI Flaw Disposition Worksheet ImnhMa>
Sketch or Photo: J:IlSlDataliSflP2o05 outageIScanslWeDyne Vessel FlawssO5502O N-10FIaw Disposition 3.bmp ImnhMa>
4TcD- I Site/Unit;       P z..     ,         ,,                                      Procedure:   P1 r- r-                     5'/-&'z               Outage No.-:     toZr   pz f       S St.nmmnry No.:            C:-0 5: o. _n                                      Procedure Rev.:                      C                                    Report No.:     :25co   V'S     .2 /
ISI Flaw Disposition Worksheet Site/Unit; P z..,
Workscope -                                                            Work Order No.:            :    LvO G        G 7      0                          Page:             of
St.nmmnry No.:
: 1) Flaw Number                       .3~                               3)151Interval                          __        _    __    _  _                <D  OK Reviewer
C:-0 5: o. _n Workscope -
: 2) Item Number             1>'~       . C90                           4) Code Edition - Addenda                 /"989           .. /     ,4.0.0.             OK 1 Reviewer      C
Procedure: P1 r-r-5'/-&'z Procedure Rev.:
: 5) Acceptance Standard                             EZ i-     .5? -/;
C Work Order No.:
* OK Reviewer Lu,.'      ")AJ/ -/ 0 (3) Calculations (See Below)                                                           a  OK Reviewer J            &-e'OI?                              11      =
LvO G G 7 0 4TcD-I Outage No.-:
a?,   2'
toZr pz f S
            ,7/'        /- 0.         '(                  ~        e1
Report No.:
                                                                              ,> -      /.      O0 <'5
:25co V'S  
: 7) Results         C@ OK Reviewer aI   -        f         Code allowable aWt%               -  a     2. Li-       Calculated a/t%           -/_   07           Laminar flaw surface area: (0.75           1 w)     Aw B) Table used for       analysis             !1OK      Reviewer                         _  =1 J B0-   3S'             -/
.2 /
: 0) Was linear Inlerpolation used?                       0   Yes
Page:
* No     If no. why?
of
t0)   Was IWA-3200 Slgntiicanrt             igilts   For Linmiting Values followed?                   I Yes               0 No         Iflno. why?
: 1) Flaw Number  
: 11) Tho correct Code Editiorn and Addenda was available and used.                                       G     Yes         Preparer             er77i*-       0   OK Reviewer
.3~
: 12) Statement of acceptability or rejoctabilltywith                       basis. 4     OK Reviewer                               4     Accept       0   Reject (0   (all) Code allowable > (all)             calculated 0   OEM flaw evaluation handbook (see attached analysis)
: 2) Item Number 1>'~. C90 Lu,.'
O   (a/t) Code allowable           (aWt) calculated 3I Prep         bynd     tal                                                                       1tilnvaring                     Iv woy and date
") AJ/ -/ 0 J
::              -.          C)6?L4'&sect;' *g5       -,;  '
&-e'OI?
The results are correct and the methodology used Is In accordance                                  Thislaew assures that the results are correct and tha with applicable codas. standards, specifications and procedures.                                    methodology used is in accordance with applicable codes.
11
=
,7/'
/- 0.
'(
~
e1 3)151 Interval
: 4) Code Edition - Addenda  
/ "989  
.. /,4.0.0.
: 5) Acceptance Standard EZ i-  
.5?  
-/;
(3) Calculations (See Below) a?, 2'
/.
O0 <'5
<D OK Reviewer 1
OK Reviewer C
OK Reviewer a
OK Reviewer
: 7) Results C@ OK Reviewer aI f
Code allowable aWt%
a
: 2. Li-Calculated a/t%  
-/_
07 Laminar flaw surface area: (0.75 1 w)
Aw B) Table used for analysis  
!1 OK Reviewer  
=1 J B0 - 3S'  
-/
: 0) Was linear Inlerpolation used?
0 Yes No If no. why?
t0)
Was IWA-3200 Slgntiicanrt igilts For Linmiting Values followed?
I Yes 0 No Iflno. why?
: 11) Tho correct Code Editiorn and Addenda was available and used.
G Yes Preparer er77i*-
0 OK Reviewer
: 12) Statement of acceptability or rejoctabilltywith basis.
4 OK Reviewer 4
Accept 0
Reject (0
(all) Code allowable > (all) calculated 0
OEM flaw evaluation handbook (see attached analysis)
O (a/t) Code allowable (aWt) calculated 3I Prep bynd tal The results are correct and the methodology used Is In accordance with applicable codas. standards, specifications and procedures.
1tilnvaring Iv woy and date C) 6?L4'&sect;' *g5 Thislaew assures that the results are correct and tha methodology used is in accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
I nle.zt
: 15) A~roved byd dale.
: 15) A~roved byd             dale   .
I nle.zt 1  
1.3                 .       *vS This approval assures that alt involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the nmethodology are correct and In accordance with applicable codes. standards, specifications and procedures.
.3  
..*vS This approval assures that alt involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the nmethodology are correct and In accordance with applicable codes. standards, specifications and procedures.
Additlonal - 1tS Flaw Disposition radit fron, Setup-Additional - Supplemental Reports <edit from Setup>
Additlonal - 1tS Flaw Disposition radit fron, Setup-Additional - Supplemental Reports <edit from Setup>


Line 470: Line 1,253:


==SUMMARY==
==SUMMARY==
 
PLANT NAME Prairie Island Unit 2
PLANT NAME                 Prairie Island         Unit                       2 WELD NO.               N10 (505020)       COMPONENT             Outlet Nozzle to Shell @ 208.50 LIMITATIONS:       NO E                   YES [I                 78.56 % Complete See Coverage Breakdown Sheet RESULTS                                   NO. OF INDICATIONS           3 NI                                       STATUS             Code Allowable RI     X EXAM DOCUMENTATION                   INDICATION DOCUMENTATION FU PARAGON ANALYSIS LOG                           [K1ASSESSMENT SHEET LII PARAGON ACQUISITION         LOG               [XI PARAGON HARD COPY m7I SCAN PRINT OUT                               [I] OTHER (Specify)
WELD NO.
N10 (505020)
COMPONENT Outlet Nozzle to Shell @ 208.50 LIMITATIONS:
NO E YES [I 78.56 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 3
NI STATUS Code Allowable RI X
EXAM DOCUMENTATION INDICATION DOCUMENTATION FU PARAGON ANALYSIS LOG
[K1ASSESSMENT SHEET LII PARAGON ACQUISITION LOG
[XI PARAGON HARD COPY m7I SCAN PRINT OUT
[I] OTHER (Specify)
LII COVERAGE BREAKDOWN Comments:
LII COVERAGE BREAKDOWN Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
Analyst     /       j       Date: 6
Analyst  
/
j Date: 6


R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME                     Prairie Island WesDyne WELD NO.                     N10 (505020)
R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.
International COMPONENT           Outlet Nozzle to Shell @ 208.5&deg; BEAM ANGLE BREAK DOWN BEAM DIRECTION             45 Shear         45 L Single           45 L Dual   Combined Bore/Star WELD I VOLUME     WELD IVOLUME WELD VOLUME WELD                 VOLUME TAN Scan Parallel         54.33     28.52 64.28     56.90     71.82     69.79 Combined Bore&Star   _
N10 (505020)
Perpendicular     _                                                        99.68     99.35 AVERAGE                     41.42           60.59               70.80           99.52 Comments:       Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
International COMPONENT Outlet Nozzle to Shell @ 208.5&deg; BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD I VOLUME WELD IVOLUME WELD VOLUME WELD VOLUME TAN Scan Parallel 54.33 28.52 64.28 56.90 71.82 69.79 Combined Bore&Star Perpendicular 99.68 99.35 AVERAGE 41.42 60.59 70.80 99.52 Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.
Combined Perp.
Combined Perp.
Analyst
Analyst w
* w   ,
I/
                                            /
/
I/                                                                 iII
i
                                      /
/
II


                              . I. i-I.1
. I. i-I.1
                                                                /~
/
                                      /             /       /~
/
                                    /             /        /~
/
                                                /
/
(9.18)                                         /
/~
                                            /
/~
WALL X/
/~
R66O00 to Cladl
/
                                    /
(9.18)
                              /
WALL
                            /               /
/
                          /               /
/
                        /               /
X/
                      /             /
R66O00 to
Transducer Sled Package 11 Figure? 1                             26853 Tarn CoveraQe Illustration Primaryylutl %etNozzle Protrusion Limitation
/
/
/  
/
Cladl Sled
/  
/
/
/
/
/
Transducer Package 11 Figure Tarn CoveraQe Primary ylutl Protrusion
? 1 26853 Illustration
%et Nozzle Limitation


Ultrasonic Examination NMl)
NMl)
Site/Unit:   PINGP     /       P12                 Procedure:           UT-Vendor           Outage No.:         E031 Summary No.:                51D0727                Procedure Rev.:                0                Report No.:     2005VE023 Workscope:                  ISI                  Work Order No.:            0406670                  Page:     1     of     9 Code:               1989 Edition             Cat./ltem:       B-D/B3.90         Location:               Containment Drawing No.:                   2-ISI-40                
Ultrasonic Examination Site/Unit:
PINGP  
/
Summary No.:
51 Workscope:
P12 D0727 Procedure:
Procedure Rev.:
Work Order No.:
UT-Vendor 0
Outage No.:
E031 Report No.:
2005VE023 Page:
1 of 9
ISI 0406670 Code:
1989 Edition Cat./ltem:
B-D/B3.90 Location:
Containment Drawing No.:
2-ISI-40  


== Description:==
==
SI Nozzle to Vessel Weld Loop A System ID:         RV Component ID: N-8                                                 Size/Length:       NA           Thickness/Diameter:   9.17"/11.58" Limitations:       See WesDyne exam report Comments:
Description:==
SI Nozzle to Vessel Weld Loop A System ID:
RV Component ID: N-8 Size/Length:
NA Thickness/Diameter:
9.17"/11.58" Limitations:
See WesDyne exam report Comments:
See supplements and Refer to the applicable WesDyne report found in the book:
See supplements and Refer to the applicable WesDyne report found in the book:
Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
  *59.26%, See WesDyne final report for details Results:             NAD   D]         IND i         GEO   L         Indications allowable by Code Percent Of Coverage Obtained > 90%:               *No                 Reviewed Previous Data:           Yes Examiner       Level II               Signature               Date Reviewer                           Sign ture             ;  Date VENDOR, WESDYNE                                           5/15/2005 Jones, Thomas             -
*59.26%, See WesDyne final report for details Results:
Examiner       Level N/A             Signature               Date Site Review                         SignatureLv     C       Date NIA                                                                 Wren, Jerry P                                                 =AAJw-Other           Level N/A             Signature               Date ANII Review         LI             Signature                 Date NIA                                                                 Daly, Gerald           Iydd/ md.QS                   IS-,uc-OS
NAD D]
IND i GEO L Indications allowable by Code Percent Of Coverage Obtained > 90%:  
*No Reviewed Previous Data:
Yes Examiner Level II Signature Date Reviewer Sign ture Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas Examiner Level N/A Signature Date Site Review SignatureLv C
Date NIA Wren, Jerry P  
=AAJw-Other Level N/A Signature Date ANII Review LI Signature Date NIA Daly, Gerald Iydd/ md.QS IS-,uc-OS


Supplemental Report NM)                                                                                                                                                                      Report No.:                 2005VE023 Page:         2         of       9 Sumnmary No.: 500727
NM)
__        -        I Examiner:       VENDOR, WESDYNE                                               Level:       11           Reviewer: Jones, Thoma S                                                          Date:               _/___S_
Supplemental Report Report No.:
Examiner          N/A                                                          Level:      NIA       Site Review: Wren, Jerry P                                                             Date:        F-&-'oS Other:      NIA                                                          Level:     NIA       ANII Review: Daly, Gerald                         .      \
2005VE023 Page:
I400   _
2 of 9
Date:             1 U'
Sumnmary No.: 500727 Examiner: VENDOR, WESDYNE Examiner N/A Other: NIA I
Comments:
Level:
Sketch or Photo: J:\lSIDatalSt\P12_05 outage\Scans\WeDyne Vessel Flaws\500727 N-8\Flaw Sizing 1.bmp ISI Flaw Sizing Worksheet N   lviYE-Site/Unit:             P         I     .2                                       Procedure:               1zt          ZS4/ &#xa2;-Outogo                           No:         PX7,,-                 S Summary No.:            :5    e    e      7 i    '7                          Procedure Rev.:                         O                             Report No.:             ;soos     V Worksrope:                .      5                                          Work Order No.:                                 S   -7D 0                       Page:                   of
11 Reviewer: Jones, Thoma Level:
: 1) Flow Nuitber                                                            3) ISI Interval                                 __  ___&            __                    OK   Reviewer
NIA Site Review: Wren, Jerry P Level:
: 2) Item Number                      B        -_        0o                  4)   Code Edition   & Addenda             19j             ^/9 , o     .        gt4 OK Reviewer
NIA ANII Review: Daly, Gerald S
: 5)   Method                                                   r T-o)   Flow Sketch (See Below)                                                       4   0 OK Reviewer         c&,
I400 Date:
Flaw View
_/_ __S_
                                                                                                                                                                              -              ,    ev /
Date: F-&-'oS Date:
                                                                                                                                                                                                                        ,  4, I
1
                                                                                                                                                                      ,4,v         s t%   2 /       0
\\
                                                ;,.3q2      j    I a?                    >                              vi                      5 I      f                          :.      * .,'..:.c
U' Comments:
__.          .:=.:                   _=_           .c     .,,_    -          -Z/;
Sketch or Photo: J:\\lSIDatalSt\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Sizing 1.bmp N lviYE-Site/Unit:
Ck             tl   e OL U
P I  
: 7) Calculations                     O   OK Reviewer               c_       J SI.1w det.nr liwation or Surface of                     ubaurfac         )
.2 Summary No.:
Show determination of type of -a                     to use
:5 e
__~J <.-
e 7 i
: 8)     fZE-4     Paragraphh.1'-                                       wedwas ad        used             0i Yes         Preparer                             OReviewer OK                              __-7>-
'7 Worksrope:
: 0) Code Flaw Dimensions                               OK 01< Reviewer                 .J
5
                    -      . 7- 5         -a-         Z   o       -t noinrnoa- '                     t   measurod         -          /               s -   ;                    NV w -      A
: 1) Flow Nuitber
: 10) Flaw Type                                             0 OK Reviewer                     h   5-.-S 4
: 2) Item Number B
1t) Flaw Characterization Figure                         V   OK Reviewer                                 ,4
0o Flaw View ISI Flaw Sizing Worksheet Procedure:
                                                                                                                    .:-          S3    t           -/
ZS4/ &#xa2;-Outogo No:
: 12) Flow CharacterizatIon Flgurc Number                                                 /
PX7,,-
: 13) Was IWA-3300 Flaw Characterization followed?                                       < Yes         0   No       If no why?
1zt S
: 14) The correct Code Edition and Addenda                             was available and used.           e    Yes        PreparererC.                            0> Ol< RevIewer &deg;_
Procedure Rev.:
: 15)     =     Fd   by                                     Aan=-,/L.-J               / Sf >             1G) Rcve                a      dal                                            __        _
O Report No.:  
The rSzfit aae correct and                 the methodology used Is In accordance                       The review assures that the results are correct and the with applicable codes. standards. specifications and procedures.                                        methodology used Is In accordance with applicable codes.
;soos V Work Order No.:
S -7D 0
Page:
of
: 3) ISI Interval OK Reviewer
: 4) Code Edition & Addenda 19j  
^/9, o gt4 OK Reviewer
: 5) Method T-r o) Flow Sketch (See Below) 4 0 OK Reviewer c&,
e v
/
,4,v s t%
2 /
0
*.,'..:.c  
-Z/;
a?
5 vi
.:=.:
_=_  
.c  
;,.3q2 j I I
f 4, I Ck tl e OL U
: 7) Calculations O
OK Reviewer c_
J SI.1w det.nr liwation or Surface of ubaurfac  
)
Show determination of type of -a to use
__~J
: 8) fZE-4 Paragraphh.1'-
ad wedwas used 0i Yes Preparer OK OReviewer
__-7>-
: 0) Code Flaw Dimensions 01<
OK Reviewer  
. J 7-5  
-a-Z o  
-t noinrnoa- '
t measurod  
/
s -
w NV A
: 10) Flaw Type 0 OK Reviewer S
h 5-.-
4,.
1t) Flaw Characterization Figure V
OK Reviewer  
,4 3
S t  
-/
: 12) Flow CharacterizatIon Flgurc Number  
/
: 13) Was IWA-3300 Flaw Characterization followed?  
< Yes 0
No If no why?
: 14) The correct Code Edition and Addenda was available and used.
: 15)  
=
Fd by Aan=-,/L.-J  
/
Sf >
The rSzfit aae correct and the methodology used Is In accordance with applicable codes. standards. specifications and procedures.
e Yes PreparererC.
0> Ol< RevIewer &deg;_
1G) Rcve a
dal The review assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
Add,60enat - 131FI.- SIX.           radiI iro., S.WLu~
Add,60enat - 131 FI.- SIX.
radiI iro., S.WLu~
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM                                                                                                                                                        Report No.:         2005VE023 Page:       3       of     9 Summary No.: 500727 i
NM Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner NIA Other: NIA Supplemental Report Report No.:
Examiner: VENDOR, WESDYNE                                            Level:       _1           Reviewer: Jones, Thoma S                          C8-;iJ              Date:       _ _/___
2005VE023 Page:
Examiner          NIA                                                Level:      NIA       Site Review: Wren, Jerry P                                                 Date: 2-c-s Other: NIA                                                      Level:       NIA       ANII Review: Daly, Gerald                                                 Date:     IS4t~x;-c~
3 of 9
i Level:
_1 Reviewer: Jones, Thoma Level:
NIA Site Review: Wren, Jerry P Level:
NIA ANII Review: Daly, Gerald S
C8-;iJ Date:
_ _/_ __
Date: 2-c-s Date:
IS4t~x;-c~
Comments:
Comments:
Sketch or Photo: J:XlSlDataUSl\Pl2 05 outage\ScanstWeDyne Vessel Flawst500727 N-6Flaw Disposition 1.bmp ISI Flaw Disposition Worksheet NMCj Sile/Unit:     P Z i/                Z_                               procedure:   Ptr-                       5 '/-sgr-iJ'.Outaoe           No.:   P:=z. jep SummaryNo.:            SOO 7,> ;L                                      Procedure Rev.:   __                                               Report No.:     _200i vC5 Workscope:                            S                          Work Order No.:         ) Lb/       Lao 7 c>                             Page:             of
Sketch or Photo:
: 1) Flaw Number                     /                           3) ISI   Interval                   _          _      _        _      _      O  OK Reviower            C
J:XlSlDataUSl\\Pl2 05 outage\\ScanstWeDyne Vessel Flawst500727 N-6Flaw Disposition 1.bmp NMC j Sile/Unit:
: 2) lien, N,,nher           EB 3 . q   0                   4)   Code Edition & Addenda             /   58 9         A/4     ,4..
P Z  
* OK R.vioar
/
: 5) Acceptance Standard                           ir r- 5i s5/     ).;         C> OK Review:er          pJ J6     t     U     ^/       6                           i6) Calculations (See Below)                                                   O   OK Reviewer 6'     = 60. 7Q                             t_=                  -2 a/p.~ g.Z6-1 01te '%, =           ? - / -7
i Z_
                  = 5 &          =       J3-         2-                   -
SummaryNo.:
Cej        /-O
SOO 7,> ;L Workscope:
: 7) Results           O OK Roviewcta29_1L.-
S ISI Flaw Disposition Worksheet procedure: Ptr-5 '/-sgr-iJ'.Outaoe No.:
nAl -   t.24"7         Code allowable ei/t% -           S. 8     Lv0'-   Calculated &lt%       ;    -      ?       Laminar L            flaw surface nroa: (0.75 1 w) -
P:=z. jep Procedure Rev.: __
: 13) Table used for analysis                   *P OK Reviewer&deg;               ._1       Zw P a -  3St 1f) Was linear Irnterpolation used?                 CD Yea         Ivl No       If no. why?
Report No.:
e9C C ec>+P     4"z       IC>'
_200i vC5 Work Order No.:  
t<        6 :l/ 4ea        S                            42E                  C-             3-
) Lb/
Lao 7 c>
Page:
of
: 1) Flaw Number  
/
: 3) ISI Interval
: 2) lien, N,,nher EB 3  
. q 0
: 4) Code Edition & Addenda  
/ 58 9 A/4  
,4..
: 5) Acceptance Standard ir r-5i s5/ ).;
J6 t
U  
^/
6 i6) Calculations (See Below)
O OK Reviower C
OK R.vioar C> OK Review:er pJ O
OK Reviewer 6'  
= 60. 7Q a/p.~ g. Z6-1 t_=
-2 01te '%, =  
? - / -7
= 5  
=
J3-2-
Ce j
/-O
: 7) Results O OK Roviewcta29_1L.-
nAl -
t.24"7 Code allowable ei/t% -
S.
8 Lv0'-
Calculated &lt%
L
?
Laminar flaw surface nroa: (0.75 1 w)
: 13) Table used for analysis  
*P OK Reviewer&deg;  
._1 Zw 3St P a 1f) Was linear Irnterpolation used?
CD Yea Ivl No If no. why?
e9 C C ec>+ P t<
4"z a
IC>'
6
:l/
4e C-S 3-42E
: 10) Was IWA-3200 Significant Digits For Llniting Values (ollowed?
: 10) Was IWA-3200 Significant Digits For Llniting Values (ollowed?
* Yes           0   No         If no. why?
Yes 0 No If no. why?
: 11) The correct Code Edilion and Addenda was avallable and used.                                 4i Yes         Prsearer         2R&   t-
: 11) The correct Code Edilion and Addenda was avallable and used.
* Ot Reviewer       -T-AtJ
4i Yes Prsearer 2R& t-
* Ot Reviewer  
-T-AtJ
: 12) Sttlement of accoplability or rejoetabilily with basis.
: 12) Sttlement of accoplability or rejoetabilily with basis.
* OK Review-r         7A.                 ID     Accept     0 Roject 4V (alt) Code allowable             (ant) calculated
OK Review-r 7A.
                ) OEM flaw evaluation handbook (see attached analysis)
ID Accept 0 Roject 4V (alt) Code allowable (ant) calculated
C) (a/lt) Code allow-able - (alI) calculated 1qrnd 14)by   't     -              Ieyng     and date
) OEM flaw evaluation handbook (see attached analysis)
              .            -r PM rra                                                                     E                C           JGf                           7 /_z'       5-lsulls         are correct and the methodology used is In accordance                     This review assures that thte results                 are correct and the with applicable codes. standards, specifications and procedures.                           methodology used Is In accordance with applicable codes.
C)
(a/lt) Code allow-able - (alI) calculated 1qrnd by  
't
: 14)
Ieyng and date PM E
-r rra C
JGf 7 /_z' 5-lsulls are correct and the methodology used is In accordance This review assures that thte results are correct and the with applicable codes. standards, specifications and procedures.
methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
t5) Aqroved by anida This approval assures that all Invofvcd with this naw sizing and naw disposition were aware of the necessity that the results and the methodology are correct and In occordanco with applicable codes. standards. specifications and procedures.
t5) Aqroved by anida This approval assures that all Invofvcd with this naw sizing and naw disposition were aware of the necessity that the results and the methodology are correct and In occordanco with applicable codes. standards. specifications and procedures.
Addllon.1 - ISI Fl-w Dlsrpe.llan -. dit *ron- S.top-Additional - Supplemental Reports <edit from Setup>
Addllon.1 - ISI Fl-w Dlsrpe.llan -. dit *ron-S.top-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                        Report No.:           2005VE023 Page:         4       of   9 Summary No.: 500727 Examiner: VENDOR, WESDYNE                                                       Level:       11         Reviewer: Jones, Thomas                         .
NM)
_        ._          Date:    4k<1/os Examiner: NIA                                                                    Level:     NIA       Site Review: Wren, Jerry P                                         9      t      Date:       Cs  ';-
Supplemental Report Report No.:
Other: NIA                                                                  Level:      NIA     ANII Review: Daly, Gerald                                         -         a     Date: ISALuff S L)
2005VE023 Page:
4 of 9
Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:
11 Reviewer: Jones, Thomas Level:
NIA Site Review: Wren, Jerry P Level:
NIA ANII Review: Daly, Gerald Date: 4k<1/os 9
t Date:
-5
-Cs a
Date: ISAL uff S L)
Comments:
Comments:
Sketch or Photo: J:\ISIDataXlSl\PI2_05 outage\Scans\WeDyne Vessel Flaws\500727 N-81Flaw Sizing 2.bmp ISI Flaw Sizing Worksheet INM                         ____
Sketch or Photo: J:\\ISIDataXlSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-81Flaw Sizing 2.bmp INM Sitejunit:
Sitejunit:         P *-       i     .-2.                                   Procedure:                                           :;-Az     -utage       No.:     PoXrz     fQ S Summary No.:                So        O .      7                          Procedure Rev.:                           0                             Report No.:           -?OS LEO       OA5 Workscope:                        S                                          Work   Order No.:               '   YD -                                           Page:             or
P *-
: 1)  Flaw Number            _                    _-                          3) ISI Interval                         ____a                                     O   OK Reviewer             1
i  
: 2) Item Number                      B        3,      9FO                      4) Code Edition & Addenda                   9g0     ,.4,/0              O             OK Reviewer       -:      _J
.-2.
: 5) Method                                       ,-      T
Summary No.:
              "_      eI                      A/-S2)                                  6) Flow Sketch (See t3elow)                                                       0     OK Reviewer         t_
So O.
Flaw View
7 Workscope:
                                                                                                                                                                    .      s     . fio   3
S
                                                                                                                                                                            = "'    7 C *.Ab
: 1) Flaw Number
: 7) Calculatlons                   V     OK Reviewer.'!S)1 Show deterninatlon of S~ure                               a       e-)
: 2) Item Number B
Show determination or type of 'a'                       to use
3, 9FO ISI Flaw Sizing Worksheet Procedure:
:S-I             e -.- g     I,     77-    .        -
:;-Az  
8)-is4-FcE-4 Paragraph-r-.                         .dW             ' Mttj       was used             *P Yes          Preparer                              i0 OK Reviewer        7            '
-utage No.:
: 9)   Code Flaw Dimensions                     O       OK Revlewer J
PoXrz fQ S Procedure Rev.:
                -r       ..    '7.         e' -     0V/0             't   nominei     -                t measured' - -                                  s4 -'_ 3.      2.          _
0 Report No.:  
: 10) Flaw Type                                             _    OKI Revieworc7             J       -5    -  o    _s _                .- >co 1t) Flaw Characterization Figure                         4       OK Reviewerr           W           =='              _~
-?OS LEO OA5 Work Order No.:  
                                                                                                                                - 3                -. /
' YD -
: 12) Flaw Characterization Figure Number                                             :$^ /
Page:
        '13) Was IWA-3300 Flaw Characterization followed?                                       O Yes       O0 No           If no. why?
or
: 14) The correct Code Edition and Addenda was available and used.                                          *9  Yes        Preparer              C
: 3) ISI Interval
* OK RovilWewerI4.          .
____a O
I K               ebto(/-Uj                                 a                   a SfS     5           16)  Rw                adeI The           Ivultsare correct and the methodology used Is In accordance                             The review assures that                 the results are correct and the with applicable codes. standards. specfications                              and procedures.            methodology used Is In accordance With applicable codes.
OK Reviewer 1
: 4) Code Edition & Addenda  
/0 9g0  
,.4, O
OK Reviewer
_J
: 5) Method T
: 6) Flow Sketch (See t3elow) 0 OK Reviewer t
eI Flaw View A/-S2) s fio 3
=
7 C *.Ab
: 7) Calculatlons V OK Reviewer.'!S)1 Show deterninatlon of S~ure a
e-)
Show determination or type of 'a' to use
:S-I e -.-
g 7-I, 7
8)-is4-FcE-4 Paragraph-r-.  
.dW  
' Mttj was used
: 9) Code Flaw Dimensions O
OK Revlewer J
-r  
'7.
e' -
0V/0  
't nominei
: 10) Flaw Type OKI Revieworc7 J
1t) Flaw Characterization Figure 4
OK Reviewerr W
: 12) Flaw Characterization Figure Number
:$^ /
'13) Was IWA-3300 Flaw Characterization followed?
O Yes
*P Yes Preparer i0 OK Reviewer 7
t measured' - -
s4 -'_ 3.
: 2.
_ o s
.- > co
 
=='
_~ 3
.- /
0 O No If no. why?
: 14) The correct Code Edition and Addenda was available and used.
I K ebto(/-Uj a
a SfS 5
The Ivults are correct and the methodology used Is In accordance with applicable codes. standards. specfications and procedures.
AddifleOrI - 151 Fltw Si.. '.dit fr e Ct.ip.
*9 Yes Preparer C
* OK RovilWewerI4.
: 16) Rw adeI The review assures that the results are correct and the methodology used Is In accordance With applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
AddifleOrI - 151 Fltw Si..          '.dit fr e        Ct.ip.
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM&)                                                                                                                                                         Report No.:         2005VE023 Page:         5     of     9 Summary No.: 500727 Examiner: VENDOR, WESDYNE                                                 Level:         11         Reviewer: Jones, Thomas                         -=Tz                Date:      _/_/_s 24-Examiner: NIA                                                            Level:       N/A       Site Review: Wren, Jerry P                                       -
NM&)
Date:    Y          Other: NIA                                                          Level:       NIA       ANII Review: Daly, Gerald                                                 Date: 15SAu,4c Comments:
Supplemental Report Report No.:
Sketch or Photo: J:\lSlData~lSltPl2_05 outage\Scans\WeDyne Vessel Flaws\500727 N-8\Flaw Disposition 2.bmp ISI Flaw Disposition Worksheet Site/Unit:         P :Z     /                                           Procedure:   P0-Zsr-                     5'!-s         tPlOutaoo   No.:   /4lo     I Summary No.:                        4  7  3 n                          Procedure Rev.:     _      _            _              _        Report No.:   2Csa5   L/6- 0   _
2005VE023 Page:
Workscope:                              2S                          Work Order No.:           O     -v 0   eo (, 7 0                       Page:       _    of
5 of 9
: 1) Flaw Number           ______-                                    3) ISI Interval
Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:
* OK Roviawer
11 Reviewer: Jones, Thomas Level:
: 2) Item Number                 B 3 . q? 0                           A) Code Edilion & Addenda               /5989           "-Vo     .. &'      40    K Reviewer        ,    -1
N/A Site Review: Wren, Jerry P Level:
: 5) Acceptance Standard                  .Z'-&V L-       % 5./aR               O OK Reviewer f,      ,.  /6        ff      )  -                          e) 6, Calculations    (See Below)                                              4   OK Rnviewar       ___
NIA ANII Review: Daly, Gerald
6'9 =9         ~/     0 ef = 9 - :Z j/=             e2,-'7 -                         Vlt, = eq, t,/ 0 a 7
-=Tz24-Date:
                      /'          /3.3 vle -Z' = /' 09
_/_/_s Date:
: 3. 7s-/0,                 /,o         -    S ~,7
Y Date: 15SAu,4c Comments:
                                                                                          ~'-,Vcr
Sketch or Photo:
J:\\lSlData~lSltPl2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Disposition 2.bmp Site/Unit:
P :Z  
/
Summary No.:
4 7
3 n Workscope:
2 S ISI Flaw Disposition Worksheet Procedure: P0-Zsr-5'!-s tPlOutaoo No.:  
/4lo I
Procedure Rev.:
Report No.:
2Csa5 L/6- 0 Work Order No.:
O  
-v 0 eo (, 7 0 Page:
of
: 1) Flaw Number
: 3)
ISI Interval
: 2) Item Number B 3. q? 0 A) Code Edilion & Addenda
: 5) Acceptance Standard f,
,. /6 ff
) -
6, e) Calculations (See Below)
/5989  
"-Vo  
.Z'-&V L-  
% 5./ aR
* OK Roviawer 40 K Reviewer
-1 O OK Reviewer 4
OK Rnviewar 6'9 =9  
~/ 0 j/=
e2,-'7 -
/'
/3.3 ef = 9 - :Z Vlt, = eq, t,/ 0 a 7 vle -Z' = /' 09
: 3. 7s-/0,  
/,o S ~,7
~'-,Vcr
: 7) Results
: 7) Results
* OK Revieer               r&#xb6;i. A a/t -   -.9     / -3       Code allowable a/t% -               .?. 5-   Z-s     Calculated alrt     -  /. 09           Laminar flaw surface area: (0.75 1 w) _
* OK Revieer r&#xb6;i.
I) Tablo used for analysis                   O   OK Revlewer-7%=             J               Bt- 3       1J.,. t -,
A a/t -
: 9) Was linear Interpolation used?                       ) Yes         0   No     If no, why?
-.9  
xeeL      -e   '   Ak b Ce.                 'e                       ico,         c       o_
/ -3 Code allowable a/t% -
C--                        /t.     .r   S
.?. 5-Z-s Calculated alrt  
: 10) Wos IWA-3200 Significant Digits For Limiting Values followed?                                 <0 Yes               0   No     If no. why?
/. 09 Laminar flaw surface area: (0.75 1 w) _
: 11) Tho correct Code Edition and Addenda was avaliable and used.                                 a     Yes         Preparer                       4P OK Reviewer
I) Tablo used for analysis O
: 12) Statement of acceptability or rejectabilily with basis.                         J0 OK Reviewer                 J             0   Accept     O Reject Ql (n/) Code allowable > (n/t) caiculalOd 0 OEM flaw evaluation handbook (see attached analysis)
OK Revlewer-7%=
C) (a/t) Code allowable f (a/t) calculated t       mppred by anddato,                                                                       14) Enginooring revig               by nnd date
J J.,.
: 4       d b y               d a Cgd            v .         _ _ _ _ _ _ _ _                          __ _0__           _ _  _ _ _    _ _ _  _ _
Bt - 3 1
The results are correct and the methodology used Is in accordance                               This review assures that the results are corroect and the with applicable codes. standards. speceficntions nnd procedures.                                 methodology used Is In accordance with applicable codes.
t -,
: 9) Was linear Interpolation used?  
) Yes 0
No If no, why?
xe eL -e  
' Ak b Ce.  
'e
: ico, c
o _
/t.  
.r S
C--
: 10) Wos IWA-3200 Significant Digits For Limiting Values followed?  
<0 Yes 0 No If no. why?
: 11) Tho correct Code Edition and Addenda was avaliable and used.
a Yes Preparer 4P OK Reviewer
: 12) Statement of acceptability or rejectabilily with basis.
J0 OK Reviewer J
0 Accept O Reject Ql (n/) Code allowable > (n/t) caiculalOd 0 OEM flaw evaluation handbook (see attached analysis)
C) (a/t) Code allowable f (a/t) calculated t
mppred by anddato,
: 14) Enginooring revig by nnd date
: 4 d b y Cgd d a v.
__ _0__
The results are correct and the methodology used Is in accordance This review assures that the results are corroect and the with applicable codes. standards. speceficntions nnd procedures.
methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
1 S) Areoved by nd date
1 S) Areoved by nd date
Line 636: Line 1,718:
Adddhonal - 1t1 Flaw Olsposition "dit from Setup-Additional - Supplemental Reports <edit from Setup>
Adddhonal - 1t1 Flaw Olsposition "dit from Setup-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                                Report No.:               2005VE023 Page:           6       of     9 Summary No.: 500727 Examiner: VENDOR, WESDYNE                                                           Level:           11           Reviewer: Jones, Thomas                                 _____),                Date:     _______
NM)
Examiner: N/A                                                                       Level:        N/A        Site Review: Wren, Jerry P                                                           Date:
Supplemental Report Report No.:
Other: N/A                                                                      Level:        N/A       ANII Review: Daly, Gerald                                         IM                 Date:       IeSAL-&GqgS L)
2005VE023 Page:
6 of 9
Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: N/A Other: N/A Level:
11 Reviewer: Jones, Thomas Level:
N/A Site Review: Wren, Jerry P Level:
N/A ANII Review: Daly, Gerald
_____),
Date:
Date:
IM Date:
IeSAL-&GqgS L)
Comments:
Comments:
Sketch or Photo: J:MlSIDataXdS\P12_05                             outage\Scans\WeDyne Vessel Flaws\500727 N-80Flaw Sizing 3.bmp I
Sketch or Photo: J:MlSIDataXdS\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-80Flaw Sizing 3.bmp SiteiUnlt:
ISI Flaw Sizing Workshteet so           I SiteiUnlt:          p    Z        /      .:                                        Procedure:           r                                   -.    /zOutage           No.:       PXz             ,-S       I Summary No.:                    -:V    O          9 a  7                            Procedure Rev.:                             o                               Report No.:             OO.S VI C--2         3 Workscope:                      .2            S                                Work Order No.:                 e   eTg5-         6P -7 ;0                               Page.             of
p Z
: 1) Flaw Number                         3                                       3) ISt Interval                                      S  -e
/
* OK Reviewer        -
Summary No.:
: 2) Item Number                         B         23. 9o                         4) Code Edition & Addenda                     1 9i?         o/         As2.
-:V O
* OK Reviewer
9 a 7 Workscope:
: 5) Method                                                   .4 T-lw    V w        e          /t-            S                            6) FIDw Sketch (See Oelow)
.2 S
* OK Reviewer Flaw VI.-
ISI Flaw Sizing Workshteet so I
                                                                                                                                                                                  -        -f~eO0 0-3 It.
Procedure:
11      -.                  I C--              1    ,                                                         ,,5     'a O         ^ - s,           s
r  
                                                                                                                                                                              .-      -Z    0,
/zOutage No.:
: 7) Calculations                       C OK Reviewer                     7A. J Show dctermnlratlon of Surlflco orgftissurtac.g>
PXz  
Show determination oft                       e oI 'n   to use 4
,-S Procedure Rev.:
5 3 S A   b   e7 .'                 - .;.        X-     ' ) r. - A             ".A - -- I
o Report No.:
: 8)     -r-E-,     Paragraph7-a-                 4'o..a           zrr i..t:       was used                 @ Yes         Preparer             5               tO     OK Rerviewer         ______J_
OO.S VI C--2 3
: 9) Code Flaw Dimensions                               v   OK Reviewer 4
Work Order No.:
                    --    , ;2   5   O &deg;   'a   -      'O. 10       -t nominal       -  _                'i1 measured'       -   =     M   /                     -      73             v-v-   #
e eTg5-6P -7 ;0 Page.
A/l
of I
: 10) Flaw Type                                                 *& OK   Reviewer               i           J   . bt      -      _.4&. e-       .- P .
I
I1)   Flaw Characterizatbon Figure                           C OK Reviewer                                 =         4 -     S   5:       -    '
: 1) Flaw Number 3
: 12) Flaw Charecterization Figure Number                                                 a       /
: 2) Item Number B
: 13) Was IWA-3300 FIJw Choracterizatiorn followed?                                           0     Yes       0 No       If no, why?
: 23. 9o lw V w e
: 14) The correct Code Edition and Addonda was avaliable and used.                                               Q     Yen         Preparcer     !5!e                         O OK Reviewer-=wie.                A 1105Praparbd                 Oyd                         LiV.       e       v                                 10) Review bysad               dateJ The results are correct and the methodology used Is In accordance                                             The review assures that the res sults are correct and                          the with applicable codes. standards. speclncEllons and procedures.                                                 methodology used is In occordainca with applicable                            codes.
/t-S Flaw VI.-
standards. spectficotions and p. rocoduras.
: 3) ISt Interval S -e
AIditlonal - IS       Flaw Size *edt trfn. Setup' Additional - Supplemental Reports <edit from Setup>
: 4) Code Edition & Addenda 1 9i?
o/
As2.
: 5) Method  
.4 T-
: 6) FIDw Sketch (See Oelow) 11 I C 1
It.
OK Reviewer
* OK Reviewer OK Reviewer
-f~e O0 0-3
-Z 0,
,, 5  
' a O  
^ - s, s
: 7) Calculations C OK Reviewer 7A. J Show dctermnlratlon of Surlflco orgftissurtac.g>
Show determination oft e oI 'n to use 5 3 S A b e7. '
X -
' 4 )
: r.  
- A  
".A -
I
: 8)  
-r-E-,
Paragraph7-a-4'o..a zrr i..t:
was used
@ Yes Preparer 5
tO OK Rerviewer
______J_
: 9) Code Flaw Dimensions v
OK Reviewer 4
, ;2 O
5  
&deg;  
'a  
'O.
10  
-t nominal  
'i1 measured' -
=
M  
/
73 v-v-A/l
: 10) Flaw Type  
*& OK Reviewer i
J b t
_.4&.
e-  
.- P.
I1) Flaw Characterizatbon Figure C OK Reviewer  
=
4 -
S 5:
: 12) Flaw Charecterization Figure Number a  
/
: 13) Was IWA-3300 FIJw Choracterizatiorn followed?
0 Yes 0 No If no, why?
: 14) The correct Code Edition and Addonda was avaliable and used.
Q Yen Preparcer !5!e 1105Praparbd Oyd LiV.
e v
: 10) Review bysad date J The results are correct and the methodology used Is In accordance The review assures that the res with applicable codes. standards. speclncEllons and procedures.
methodology used is In occorda standards. spectficotions and p.
AIditlonal - IS Flaw Size *edt trfn. Setup' O OK Reviewer-=wie. A sults are correct and the inca with applicable codes.
rocoduras.
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMC)                                                                                                                                                          Report No.:         2005VE023 Page:       7       of       9 Summary No.: 500727 Examiner: VENDOR, WESDYNE                                                 Level:           _1         Reviewer: Jones, Thomas                           9f4i_ &Date:                      S_____
NMC)
Examiner: N/A                                                             Level:         N/A     Site Review: Wren, Jerry P                             S )            Date:     ___        ___
Supplemental Report Report No.:
Other: NIA                                                          Level:          N/A     ANII Review: Daly, Gerald                             JI             Date: KA CS Comments:
2005VE023 Page:
Sketch or Photo: J:\lSIData\iSI\P12_05 outage\Scans\WeDyne Vessel Flaws\500727 N-8\Flaw Disposition 3.bmp ISI Flaw Disposition Worksheet NPZ M ->
7 of 9
Site/Unit:       P   Z   /         fit_                                     Procedure:   P-.br :r-                               tV.Outage Z-5/-So-No.:                 P.2f7s SummaryNo.:               s     o       7a 7                               Procedure Rev.:     __)                                           Report No.:   VOaS*Vt     -    e'._   3 Workscope:                 Z-   5                                     Work Order No.:           6 L.o   (,( G     7   0                         Page:           of
Summary No.: 500727 Examiner: VENDOR, WESDYNE Level:
: 1) Flaw Number                   3                               3) [SI Interval                               '>      _
_1 Reviewer: Jones, Thomas Examiner: N/A Other: NIA Level:
* OK Reviewer
N/A Site Review: Wren, Jerry P Level:
: 2) Item NLumber             B&3.   .       o0                    4) Code Edition & Addenda                 / 989   <      /;       4O 0         0   OK Reviewer     CJ
N/A ANII Review: Daly, Gerald 9f4i_ &Date:
: 5) Acceptance Standard                       t   &-g-   5ST /   ;                   OK Rovtower     -_2 0 Calculations (See Below)
S_____
O)                                                                                b OK Reviewer         c     _
S )
* l9       6
Date: ___
                            '!. / O                             t=             9             _'r =-         , --.5                           >        -_        0             87 VXp =l O               g,//{                               o-           /           9 3,73/7 3              , /o           =         3 7, 3
JI Date: KA CS Comments:
: 7) Results         0   OK Reviewer               _ _
Sketch or Photo: J:\\lSIData\\iSI\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Disposition 3.bmp N
oD -     . 09'           Code allowable at%           -e             0   ZColcutalad 1A                a/t% -         O           LLaminar now surface area: (0.75         I w) -
M PZ ISI Flaw Disposition Worksheet Site/Unit:
: 8) Table used for analysis                     0 OK RevIewor               2;;_
P Z  
                                                                                      %t3-
/
                                                                                      -,;R-,                 3
fit_
        .)) Was linear Inlorpolntlon used?                   0 Yes             O     No       if no. why?
Procedure: P-.br :r-Z -5/-So-tV.Outage No.:
: 10) Was IWA-3200 Significant Digits For Limiting Values followed?                                   C   Yes     O No           It no. why?
P.2f7s SummaryNo.:
1t) The correct Code Edition and Addenda was available and used.                                     0 Yes       Preparer           5     Z2 7
s o
* OK Reviewor -7Z;J
7a 7 Procedure Rev.:
: 12) Statement of acceptability or rejectability with basis.                             0 OK Reviewer                           Q_ Accept           C Reject Ot (C/t) Coda allowable C (alt) calculated 0 OEM nfw ,valtuaton handbook (see attached analysis)
__)
C) (alt) Code allowable *c (Cat) calculated
Report No.:
: 14) Englnooino review bynd                  date The TSults are correct and the methodology Used Is In accordance                                 This review assures that the results are correct and the with applicable codes, standards, specifications and procedures.                                  methodology used Is In accordance with applIcable codes.
VOaS*Vt e'._
3 Workscope:
Z-5 Work Order No.:
6 L.o
(,( G 7 0 Page:
of
: 1) Flaw Number 3
: 3) [SI Interval OK Reviewer
: 2) Item NLumber B& 3..
0 o
: 4) Code Edition & Addenda  
/ 989  
/;
4O 0 0
OK Reviewer CJ
: 5) Acceptance Standard t
g-5 ST / ;
OK Rovtower  
-_2 0
O) Calculations (See Below) b OK Reviewer c
l9 6  
'!. / O t=
9 _'r =-
5 0
87 VXp =l O g,//{
o-  
/
9 7 3 3,73/  
, /o  
=
3 7, 3
: 7) Results 0
OK Reviewer oD -
. 09' Code allowable at%
e 0
1A ZColcutalad a/t% -
L O
Laminar now surface area: (0.75 I w) -
: 8) Table used for analysis 0 OK RevIewor 2;;_  
%t3-3
-,;R-,
.)) Was linear Inlorpolntlon used?
0 Yes O No if no. why?
: 10) Was IWA-3200 Significant Digits For Limiting Values followed?
C Yes O No It no. why?
1t) The correct Code Edition and Addenda was available and used.
0 Yes Preparer 5
Z2 7 OK Reviewor -7Z;J
: 12) Statement of acceptability or rejectability with basis.
0 OK Reviewer Q_ Accept C Reject Ot (C/t) Coda allowable C (alt) calculated 0 OEM nfw,valtuaton handbook (see attached analysis)
C)
(alt) Code allowable *c (Cat) calculated The TSults are correct and the methodology Used Is In accordance with applicable codes, standards, specifications and procedures.
: 14) Englnooino review bynd date This review assures that the results are correct and the methodology used Is In accordance with applIcable codes.
standards. specifications and procedures.
standards. specifications and procedures.
1S) Approveyd by ar         dale_ `
1S) Approveyd by ar  
rO   _I   I     i           - I!,             i)   ^- .7   :v<
`
This approval assures that all Inlved               with this naw sizing and flaw disposition were aware or the necessity that the results and the nielhodology are correct and In accordance with applicable codes. standards, specifications and procodures.
dale_
rO
_I I
i  
- I!,
i)  
^-.7
:v<
This approval assures that all Inlved with this naw sizing and flaw disposition were aware or the necessity that the results and the nielhodology are correct and In accordance with applicable codes. standards, specifications and procodures.
Addillorwl - 151 Fle.v Disposition -edit freom SetuP-Additional - Supp!emental Reports <edit from Setup>
Addillorwl - 151 Fle.v Disposition -edit freom SetuP-Additional - Supp!emental Reports <edit from Setup>


Supplemental Report N M6)                                                                                                                                                                       Report No.:             2005VE023 Page:           8         of     9 Summary No.: 500727 Examiner VENDOR, WESDYNE                                                     Level:           11             Reviewer Jones, Thomas                               sZ 4 <<ii     -          D ate:   _ _ _ _ _/   _
N M6)
Examiner          N/A                                                      Level:          N/A          Site Review: Wren, Jerry P                                        2/7             Date:       P- s--cr   <5 Other: N/A                                                              Level:          N/A        ANII Review: Daly, Gerald                          .
Supplemental Report Report No.:
Date:      ISA LI Comments:
2005VE023 Page:
Sketch or Photo: J:%ISIData\lSl\Pl2_05 outage\Scans\WeDyne Vessel Flaws\500727 N-8\Flaw Sizing 4.bmp
8 of 9
[SI Flaw Sizing Workshect NM >
Summary No.: 500727 Examiner VENDOR, WESDYNE Examiner N/A Other: N/A Level:
SltefUnlt:       P7        /     -2.                                           Procedure:                   .bE_         .        .- ,fO tageNo.,             P: zJ/         f Summary No.:              5      0 7.l        7                                Procedure Rev.:                                                         Report No.:           .oos       V     C2;     3 Workscope:                    S- 2                                            Work Order No.:               ,:9 e               i   70                           Page:             of
11 Reviewer Jones, Thomas Level:
: 1) Fln_ Number                        411/                                  3) JSI Inkerval                                     S0                                       OK Reviewer         -
N/A Site Review: Wren, Jerry P Level:
: 2) Item Numher                  a~      3.90g                            4) Cockd Edition & Addenda                           J       s4,,,    $4     _Y              OK Reviewer J
N/A ANII Review: Daly, Gerald sZ 4 <<ii D ate: _ _ _ _ _/
: 5) Method                                                 C4 -r LA, ,-      0    -.                                                  0) Flaw Sketch (See Feloew)                                                               G) OK Reviewer Flaw View I                           ___                  .  ...                                                          /.0      -.      O      -      25~
2/7 Date:
                                                                      .                                            qjg.                                              '/    -        >      r5        5.
P-s- -cr <5 Date:
                                                                                                                                                                                                          ,        --c f, %.0 ,         ,            c
ISA LI Comments:
Sketch or Photo: J:%ISIData\\lSl\\Pl2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Sizing 4.bmp NM >
SltefUnlt:
P 7
/
-2.
Summary No.:
5 0 7.l 7 Workscope:
S-2
[SI Flaw Sizing Workshect
: 1) Fln_ Number
: 2) Item Numher 411/
a~
3.90g Procedure:  
.bE_-7
.-,fO tageNo.,
P: zJ/ f Procedure Rev.:
Report No.:  
.oos V C2; 3
Work Order No.:  
,:9 e i
70 Page:
of
: 3) JSI Inkerval S0 OK Reviewer
: 4) Cockd Edition & Addenda J
s4,  
$4
_ Y OK Reviewer J
: 5) Method C4 -r
: 0) Flaw Sketch (See Feloew)
G) OK Reviewer LA,,-
0 Flaw View I
qjg.
f, %.0,
c
_f
_f
: 7) Calculations               O     OK Reviewer             --  ____
/.0 O
Show determination of Surface o$&urracei)
25~
Show determination of tye             of a     to use
'/
                -                    -,      7.2         syes --. $            +                --                              prO..-                             4         OKReviewor 8)-t4-FE- I ParagraphEC-                 S       o -p -f'     fi   At-i-was         used               6t Yes                                                                 e     ____Rv
r5 5., --c
: 9) Code Flaw Dimenslons                   40 OK Reviewer -77XJ 1-       *          -n- -    09. ' 0O_      t nominal             -    .      +/--I   '   ,s                                               _      t
: 7) Calculations O OK Reviewer Show determination of Surface o$&urracei)
                                                                                                                                                                          .sured O     -w- _
Show determination of tye of a to use 7.2 syes prO..-  
: 10) Flaw Type                                       O OK Reviewer                                           5    T.&deg;C-                         P
+
: 11) Flaw Characterization Figure                   C   OK Reviewer                           J                 A   -   5.3     .2-     _ /
4 OKReviewor 8)-t4-FE-I ParagraphEC-S o -p -f' fi At-i-was used 6t Yes
: 12) Flew Characteizatlion Figure Numbor                                             ^     /
____Rv e
: 13) Was IWA-3300 Flow Characturizatioi followed?                                       a     Yes         0 No     If no. why?
: 9) Code Flaw Dimenslons 40 OK Reviewer -77XJ 1-  
: 14) The correct Code Edition and Addenda was avevllable and used.                                             ( Yes       Preparer                                   f
-n-O_
* OK Reviewer         1-t--'..
: 09. ' 0 t nominal  
15      r          b    ad                        L.'J, r l                7
+/--I '  
                                                                                      -7    8                      1i) Revle     k       dcat,!J4         X//2 The r            are correct and the methodology used Is in accordance                                      The review ossures that the results are correct and tle with applicable codes, standards. specifications and procedures.                                            methodology used Is In accordance with applicable codes.
,s  
.sured O  
-w- _
t
: 10) Flaw Type O OK Reviewer T.&deg;C-5 P
: 11) Flaw Characterization Figure C
OK Reviewer J
A -
: 5. 3  
.2-
_ /
: 12) Flew Characteizatlion Figure Numbor  
^  
/
: 13) Was IWA-3300 Flow Characturizatioi followed?
a Yes 0 No If no. why?
: 14) The correct Code Edition and Addenda was avevllable and used.
15 r
b ad
-7 L.'J, l r
7 8 The r are correct and the methodology used Is in accordance with applicable codes, standards. specifications and procedures.
(
Yes Preparer f
* OK Reviewer 1-t--'..
1i) Revle k
dcat,!J4 X//2 The review ossures that the results are correct and tle methodology used Is In accordance with applicable codes.
standards. specifriations end procedures.
standards. specifriations end procedures.
Addj,0 -       - M5Ftla, 1~.         Six. .. d~t trol r S.I.,p.
Addj,0 -
1~.
M5 Ftla, Six... d~t trol r S.I.,p.
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                              Report No.:           2005VE023 Page:           9         of     9 Summary No.: 500727 Examiner: VENDOR, WESDYNE                                   .
NM)
Level:             II           Reviewer Jones, Thomas                                   _  _  _    _ _        Date:          '    '  s Examiner: NIA                                                                  Level:         NIA         Site Review: Wren, Jerry P Other: N/A                                                                Level:         N/A       ANII Review: Daly, Gerald                                         d4M                 Date: iSAocct LI Comments:
Supplemental Report Report No.:
Sketch or Photo: JAISIDatallSl\P12_05 outage\Scans\WeDyne Vessel FlawsX500727 N-8\Flaw Disposition 4.bmp I
2005VE023 Page:
ISI Flaw Disposition Worksheet i
9 of 9
e of0     I Site/Unit:        P  Z      /        ;                                            Procedure:       Pbz7-xsr-             . 5-s--           tPZOrta;i       No       PZr% eF         -;     !S I
Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: N/A Level:
Summary No.:            fTQQ-          7,        7                              Procedure     Rev.:                     C)                                 Report   No.:     Vc0s     Vd/       e.)   3 Workscopo:                          .5    =-S                                Work Order No.:                 O L/O       C>     7 0                           Page:               of
II Reviewer Jones, Thomas Level:
: 1) Flaw Numbor                   I/                                      3)    ISI  interval                          _              _            _Q                0  OK Reviewer
NIA Site Review: Wren, Jerry P Level:
: 2) tlem   Nu1mber           'B ---5. - C? 40                           4) Code       Edition & Addenda                 /98             "   O/a d"               Q)  OK Reviewer                      J
N/A ANII Review: Daly, Gerald Date:
: 5) Acceptance Standard                         :      & g'-     3       a'7.               oCOK Reviewer            -rnv,      S
s d4M Date: iSAocct LI Comments:
: 6)   Calculations (See           Lietow)                                                   C0 OK Roviewer           -r7-,,, S) 16'   =       9. /a Y       1=
Sketch or Photo: JAISIDatallSl\\P12_05 outage\\Scans\\WeDyne Vessel FlawsX500727 N-8\\Flaw Disposition 4.bmp Site/Unit:
                              - 0                                   0/'     -Z         e9- 0187 aV/ p1 -          ./ Q vle       7- =           /'     0 7 r(=       s/s'                   0         o       z         -.      ,
P Z
: 7) Results           O OK Reviewer               __        _
/
ai -     O.   /0           Code allowable a/t%                         .5               Calculated o/t%           ,  7...             Laminar flaw surfaco aren: (0.75 1 w) tt) Table used for analysis               Qt           OK Reviewer                     J           w   a                 -t - /
Summary No.:
: 0) Was linear irlterpolation usod?                           0   Yes         V   No         If no. Why?
fTQQ -
                                                      .- /6,-'           Re e       C- .,     -- Z-elO
7, 7
: 10) Was IWA-3200 Significant Digits For Limiting Values followed?                                               C) Yes             0 No         Ir no, wtTy?
Workscopo:
: 11) Tho correct Code Edition and Addenda was available and used.                                                 t-Yes           Preparer                           C ) OK Reviewer             J
.5
: 12) Staternent of acceptability or rojectabillty with basis.                                 0 OK Reviewer                           3       4_0    Accept         0 Reject 4   (a/t) Code allowable >- (a/t) calculated 0 OEM flow evaluation handbook (see attached analysis) 0 (tit) Corde nilawahble (sit) calculated
=-S ISI Flaw Disposition Worksheet e of0 I
: 13)       fby             8ng             ,L....JL-               -_    /   8-                             14) Enjiineorina review by and date                                        //
Procedure: Pbz7-xsr-  
The r         sare   correct and the methodology used Is In accordance                                     This review assuros that the results are correct and the with applicable codes, standards. spocificatlons and procedures.                                            methodology used Is In accordance with applicable codes.
. 5-s-- tPZOrta;i No PZr% eF -;  
!S Procedure Rev.:
C)
Report No.:
Vc0s Vd/
e.) 3 Work Order No.:
O L/O C >
7 0 Page:
of I
i I
: 1) Flaw Numbor
: 2) tlem Nu1mber I/
'B ---5. - C? 40
: 3) ISI interval
_Q
: 4) Code Edition & Addenda  
/98  
" O/a d"
: 5) Acceptance Standard  
& g'-
3 a'7.
: 6) Calculations (See Lietow) 0 OK Reviewer Q)
OK Reviewer J
oC OK Reviewer
-rnv, S
C0 OK Roviewer  
-r7-,,, S) 16' =
: 9. /a Y
1=  
- 0 aV/
1p -
./ Q 0/' -Z e9- 0187 vle 7- =  
/'
0 7 r(=
s/s' 0
o z
: 7) Results O OK Reviewer ai -
O.  
/0 Code allowable a/t%  
.5 Calculated o/t%
7...
Laminar flaw surfaco aren: (0.75 1 w) tt) Table used for analysis Qt OK Reviewer J
w a  
-t - /
: 0) Was linear irlterpolation usod?
0 Yes V No If no. Why?
.- /6,-'
Re e C-.,  
-- Z-elO
: 10) Was IWA-3200 Significant Digits For Limiting Values followed?
C) Yes 0 No Ir no, wtTy?
: 11) Tho correct Code Edition and Addenda was available and used.
t-Yes Preparer C ) OK Reviewer J
: 12) Staternent of acceptability or rojectabillty with basis.
0 OK Reviewer 4_
3 0
Accept 0 Reject 4
(a/t) Code allowable >- (a/t) calculated 0
OEM flow evaluation handbook (see attached analysis) 0 (tit) Corde nilawahble (sit) calculated
: 13) fby 8ng  
,L....JL-  
/
8-The r sare correct and the methodology used Is In accordance with applicable codes, standards. spocificatlons and procedures.
: 14) Enjiineorina review by and date
//
This review assuros that the results are correct and the methodology used Is In accordance with applicable codes.
standards, specifications and procedures
standards, specifications and procedures
: 15) Apoved by ardate                   .
: 15) Apoved by ardate This approval assures that alfinvolved with this naw sizing and naw disposition were aware of the necessity that tlha results and the methodology are correct and In accordance with applicable codes, standards, specifications and procedures.
This approval assures that alfinvolved with this naw sizing and naw disposition were aware of the necessity that tlha results and the methodology are correct and In accordance with applicable codes, standards, specifications and procedures.
Addillonal - 151 Flaw DlsposItIon 'Odit fron Setup-Additional - Supplemental Reports <edit from Setup>
Addillonal   - 151 Flaw DlsposItIon 'Odit fron Setup-Additional - Supplemental Reports <edit from Setup>


REACTOR VESSEL WELD RESULTS  
REACTOR VESSEL WELD RESULTS  


==SUMMARY==
==SUMMARY==
 
PLANT NAME Prairie Island Unit 2
PLANT NAME                     Prairie Island           Unit                         2 WELD NO.                   N8 (500727)       COMPONENT             Safety Injection Noz-Shell @108.50 LIMITATIONS:           NO     1               YES     3j             59.26 % Complete See Coverage Breakdown Sheet RESULTS                                       NO. OF INDICATIONS           4 NI                                         STATUS                     Code Allowable RI           X EXAM DOCUMENTATION                       INDICATION DOCUMENTATION 37I PARAGON ANALYSIS LOG                               mEASSESSMENT SHEET El PARAGON ACQUISITION LOG                             EKII PARAGON HARD       COPY FLE SCAN PRINT OUT                                       = OTHER (Specify)
WELD NO.
N8 (500727)
COMPONENT Safety Injection Noz-Shell @108.50 LIMITATIONS:
NO 1
YES 3j 59.26 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 4
NI STATUS Code Allowable RI X
EXAM DOCUMENTATION INDICATION DOCUMENTATION 37I PARAGON ANALYSIS LOG mEASSESSMENT SHEET El PARAGON ACQUISITION LOG EKII PARAGON HARD COPY FLE SCAN PRINT OUT  
= OTHER (Specify)
LKII COVERAGE BREAKDOWN Comments:
LKII COVERAGE BREAKDOWN Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
lt Analyst                       b,,ate:   5
l t Analyst b,,
ate:
5


R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME                         Prairie Island WesDyne WELD NO.                           N8 (500727)
R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.
International COMPONENT         Safety Injection Noz-Shell @108.5&deg; BEAM ANGLE BREAK DOWN BEAM DIRECTION                 45 Shear               45 L Single               45 L Dual   Combined Bore/Star WELD I VOLUME                     lVOLUME IWELD          WELD I VOLUME WELD I VOLUME TAN Scan           -
N8 (500727)
Parallel             15.55       57.14     0.00       53.66       0.00     28.10 Combined Bore&Star                 .
International COMPONENT Safety Injection Noz-Shell @108.5&deg; BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD I VOLUME IWELD lVOLUME WELD I VOLUME WELD I VOLUME TAN Scan Parallel 15.55 57.14 0.00 53.66 0.00 28.10 Combined Bore&Star Perpendicular 97.40
Perpendicular                                                                             97.40     88. 15 AVERAGE                       36.35                   26.83                   14.05           92.78 Comments:       Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
: 88. 15 AVERAGE 36.35 26.83 14.05 92.78 Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Combined Perp.             92.78               _pObined Para.                 25.74 Analyst                         I
Combined Perp.
                                              '- +1-   '
92.78
I
_pObined Para.
I 25.74 Analyst
'- +1-I


Figure 1 Tan Coverage Illustration of the Safety Injection Nozzle
Figure 1 Tan Coverage Illustration of the Safety Injection Nozzle


Ultrasonic Examination NM)
NM)
Site/Unit:   PINGP   /     P12                 Procedure:           UT-Vendor           Outage No.:       E031 Summary No.:                500726                Procedure Rev.:                0              Report No.:   2005VE024 Workscope:                  Is'                  Work Order No.:            0406670                  Page:   1     of   7 Code:               1989 Edition           Cat./ltem:       B-DIB3.90         Location:               Containment Drawing No.:                   2-ISI-40                
Ultrasonic Examination Site/Unit:
PINGP /
Summary No.:
5 Workscope:
P12 00726 Is' Procedure:
Procedure Rev.:
Work Order No.:
UT-Vendor 0
0406670 Outage No.:
E031 Report No.:
2005VE024 Page:
1 of 7
Code:
1989 Edition Cat./ltem:
B-DIB3.90 Location:
Containment Drawing No.:
2-ISI-40  


== Description:==
==
SI Nozzle to Vessel Weld Loop B System ID:         RV Component ID: N-11                                               Size/Length:       NA         Thickness/Diameter   9.17"/11.58" Limitations:       None Comments:
Description:==
SI Nozzle to Vessel Weld Loop B System ID:
RV Component ID: N-11 Size/Length:
NA Thickness/Diameter 9.17"/11.58" Limitations:
None Comments:
See supplements and Refer to the applicable WesDyne report found in the book:
See supplements and Refer to the applicable WesDyne report found in the book:
Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
Prairie Island Nuclear Power Plant / Unit 2 1 0-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005
  *59.26%, See Wes Dyne final report for details.
*59.26%, See Wes Dyne final report for details.
Results:             NAD   D         IND i         GEO             __
Results:
Percent Of Coverage Obtained > 90%:               *No                 Reviewed Previous Data:           Yes Examiner       Level II             Signature               Date Reviewer                           Signature               Date VENDOR, WESDYNE                                           5/15/2005 Jones, Thomas         i&1/ G   .J-                     5/S Examiner       Level N/A             Signature               Date Site Review                         Signature       v       Date NIA                                                                 Wren, Jerry P           ,      e   Vt/l- ..--
NAD D IND i GEO Percent Of Coverage Obtained > 90%:  
Other           Level N/A             Signature               Date ANII Review                         Signature               Date N/A                                                                 Daly, Gerald
*No Reviewed Previous Data:
Yes Examiner Level II Signature Date Reviewer Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas i&1/ G.J-5/S Examiner Level N/A Signature Date Site Review Signature v
Date NIA Wren, Jerry P e
Vt/l-..--
Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald


Supplemental Report NM)                                                                                                                                                                      Report No.:               2005VE024 Page:               2       of     7 Summary No.: 500726 Examiner: VENDOR, WESDYNE                                                       Level:       _1             Reviewer: Jones, Thomas                                       d5            Date:     _______
NM)
Examiner: NIA                                                                    Level:      NIA         Site Review: Wren, Jerry P                                                       Date:     ___      ___
Supplemental Report Report No.:
Other: NIA                                                                 Level:      NIA        ANII Review: Daly, Gerald                                                         Date:       1 Comments:
2005VE024 Page:
Sketch or Photo: J:UlSIData\ISI\PI2_05 outage\Scans\WeDyne Vessel Flaws\500726 N-1 1\FIaw Sizing I.bmp ISI Flaw Sizing Worksheet N         -            _            __-
2 of 7
Slte/Unit:     P             /       B.2                                       Procedure:                                         X-Aot               No.:       PX.<       Re fO-Summary No.:              -5    OO        7    a  L.                        Procedure Rev.:                           a                             Report No.:         :?oC5 VF             :
Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:
Worksoope:                .Z*                                              Work Order No.:               e   SzO6,( 2;70                                   Page:                   of
_1 Reviewer: Jones, Thomas Level:
: 1) Flaw Number                                                               3) ISI Interval                        __    _  _  _  _    __  _  _            P  OK Revlewer            _____
NIA Site Review: Wren, Jerry P Level:
a/ag
NIA ANII Review: Daly, Gerald d 5 Date: _______
: 2) Item Number                                                                4) Code Edition & Addenda                 J 9IVY             ,v X.               O    OK Reviewer 6: tj            I                                6) Method                                             ri   -
Date: ___
: 0) Flaw Sketch (See Delow)                                                       -W OK Reviewer Flaw View
Date:
                                                                                                                                                                      - 4A     =    O.   ....    'o.1 4' .LJ'r=0l ' >D ao .Zz <O. 4 o               Z R           ,/
1 Comments:
et.   -   .3     0
Sketch or Photo: J:UlSIData\\ISI\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1\\FIaw Sizing I.bmp N
: 7) Calculations                 O     OK Reviewer Show determination of Surface                                 3 Show determination of t                 e or a         to use
Slte/Unit:
                ..J'I -AM1, e - #'e -' I           'Z         gVg,;4ts..           t 3 .:-      4.--   __
P  
8)4B4-v-4Par                       77- ; .-              -    -- 4PZ           ws s
/
: 8) lMI FE . Paragrapha-7-.         Ir*r                       -                was used               C   Yes     Preparer !Z         E     J       @)   OKI Reviewer          _
B.2 Summary No.:
: 9) Code Flaw Dimensions                       M OK Reviewer                   &deg; r- _                 'a' -
-5 OO 7 a L.
                                          'Q        5 00                 I nominal - -     _9   ..     -t   ,rreasured -   -      nZ                      -  q.                 w      5ds
Worksoope:
: 10) Flaw Type                         O                         OK Reviewer           rl4k                 _5   b     ..    '.. s -* P           ^_
.Z*
t 1) Flaw Characterization Figure                           0   OK Reviewer       -7         J,4             _      3     .S       - /
ISI Flaw Sizing Worksheet Procedure:
: 12) Flaw Characterization Figure Number                                             a       /
X-Aot No.:
: 13) Was IWA-3300 Flaw Characterization followed?                                         *"   Yes     0   No     If no. why?
PX.<
: 14) The correct Code Edition and                     Addenda was avaliable             and used.           Co Yes     Preparer "ZjP4                         '11 OK Reviewer             -71%     j
Re fO-Procedure Rev.:
: 15) P              by ar                                                      7-/B -os'*                  16) Reve       bv a:~                                                       7ate     IO 5-4 The resu        are correct and the methodology used is In accordance                                    The review assures that the results are correct and the with applicable codes, standards, specifications and procedures.                                          methodology used Is In accordance with applicable codes.
a Report No.:
:?oC5 VF Work Order No.:
e SzO6,( 2;70 Page:
of
: 1) Flaw Number
: 2) Item Number a/ag 6: tj I
: 3) ISI Interval
: 4) Code Edition & Addenda J 9IVY  
,v X.
: 6) Method ri
: 0) Flaw Sketch (See Delow)
Flaw View P OK Revlewer O
OK Reviewer
-W OK Reviewer
.L =0l ' ao
<O.
- 4A O.  
=
'o.1 4' J'r  
>D.Zz 4
o Z
R  
,/
et. -
.3 0
: 7) Calculations O OK Reviewer Show determination of Surface 3
Show determination of t e or a to use
..J' I -AM1, e - #'e -' I  
'Z gVg,;4ts.. 3 t 4.--
8)4B4-v-4Par 7-7 ;  
-- 4PZ ws s
: 8) lMI FE. Paragrapha-7-.
Ir* r was used C
Yes Preparer !Z E
J
@) OKI
: 9) Code Flaw Dimensions M OK Reviewer  
&deg; r- _  
'Q
'a' -
5 00 I nominal - -
_9..  
-t  
,rreasured -
: q.
nZ
: 10) Flaw Type O
OK Reviewer rl4k
_5 b  
'.. s -*
P  
^_
t 1) Flaw Characterization Figure 0
OK Reviewer  
-7 J,4 3  
. S  
- /
: 12) Flaw Characterization Figure Number a  
/
: 13) Was IWA-3300 Flaw Characterization followed?  
*" Yes 0 No If no. why?
Reviewer w
5ds
: 14) The correct Code Edition and Addenda was avaliable and used.
: 15) P by ar 7-/B -os'*
The resu 4 are correct and the methodology used is In accordance with applicable codes, standards, specifications and procedures.
Addftional - ISI Flaw Size -edit from Setup' Co Yes Preparer "ZjP4  
'11 OK Reviewer -71% j
: 16) Reve bv a:~
7ate IO 5-The review assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specifications ancd procedures.
standards. specifications ancd procedures.
Addftional - ISI Flaw Size -edit from Setup' Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                        Report No.:         2005VE024 Page:         3         of       7 Summary No.: 500726 Examiner: VENDOR, WESDYNE                                                        Level:       11           Reviewer: Jones, Thomas                               9-xs J               Date:       *6 A'17T Examiner            NIA                                                        Level:      NIA        Site Review: Wren, Jerry P                                  a2E             Date: ,-a-c, Other: NIA                                                                 Level:     NIA       ANII Review: Daly, Gerald                                     Abr)
NM)
U' Date: ILAu&o Comments:
Summary No.: 500726 Examiner: VENDOR, WESDYNE Supplemental Report Report No.:
Sketch or Photo: J:ulSIData\ISI\P12 05 outage\Scans\WeDyne Vessel Flaws\500726 N-i1\Flaw Disposition 1.bmp ISI Flaw Disposition Worksheet NFLVID SlterUnit:       P   Z'     /       '.                                     Procedure:       Pb           r     -    5!         s--   tJOutage No.:       Pz'Z /ex Summary No.:              goo            7      .    ,                        Procedure Rev.:         __                                                 Roport No.:   .0oos       dVC 40     S/o Worksoope:                                    :-                            Work Order No.:               4     C-`0 Co o 7         0                       Page:             of
2005VE024 Page:
: 1) Flaw Number                       /                                   3) ISI Interval                                            :t                        0  OK Reviewer            q-Z2k  J
3 of 7
: 2) Item Number                 B   2   . ?   0                         4) Code Edition & Addenda                     / 98 9         A/a       '4"'         4D OK Reviewer          c,        J
Level:
: 5) Acceptance Standard                                 El     1   s.   ;;2         I    OK Reviewer        7    .
11 Reviewer: Jones, Thomas Examiner NIA Other: NIA 9-xs J Date: *6 A'17T a2E Date:,-a-c, Level:
LA I- L_ *,      d              _- '    t
NIA Site Review: Wren, Jerry P Level:
: 0) CalculatIons (See Below)                                                           Z OK Roviewer 6 -             0,                                       e-=         9-2...
NIA ANII Review: Daly, Gerald Abr)
J=              1,0                                            -7e-=e9. 0-32 4 '
Date: ILAu&o U'
            /,p        -      0'. 30 K
Comments:
r            1_7               t / ,/     '/         K9.'   30         ~-_           .'
Sketch or Photo:
L...es C_         -0
J:ulSIData\\ISI\\P12 05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-i 1\\Flaw Disposition 1.bmp NFLVID SlterUnit:
: 7) Results           0   OK Reviewer
P Z'  
        .-1 =       .0. 50        Code allowable a/t% -                     C/, */         Celculated ent%         -      . Z         Lamninar nlw        surface area: (0.75  I  w)  -            4 a) Table used (or analysts                     AW       O< Reviower                   J           xJ a-       3S _,R I;   -  i fi) Was linear Interpolation used?                           C) Yes           4   No   If rno. why?
/
1 WsL Amit-ng g avt Vitcr    o         ed   1         Ys
Summary No.:
: 10) Was       IWA-320z0     Signtricant Digits For Limiatingf                 Vniues followed?             til   Yes           O5 No         Ir no. why?
goo 7
t 1)   The correct Code Edition and Addenda was available and used.                                       O         Yes       Preparer                           *4 OK   Reviewer                 JJ
Worksoope:
: 12) Statement of acceptability or rejectability with basis.                               0 OK Reviewer -                         J                 Accept     I= Reject li     (a/t) Code allowable > (alt) calculated C) OEM flaw evaluation handbook (see attached analysis)
ISI Flaw Disposition Worksheet Procedure: Pb r
CO (0/I) Code allowable . (n/t) calculaled 13),Proppred by             d P Ii         ,                              g---,                         14) Engineering rev                    wbyan date                7
5!
                          . ,                                                12__ RI         5-Thresults       are correct and the methodology used Is In accordance                                 This review assures that the results are correct and the with applicable codes. standards. specilications end procedures.                                        methodology used Is In accordance with applicable codes.
s-- tJOutage No.:
Pz'Z /ex Procedure Rev.: __
Roport No.:.0oos dVC 40 S/o Work Order No.:
4 C-`0 Co o 7 0
Page:
of
: 1) Flaw Number  
/
: 2) Item Number B
2. ?
0 LA I-L_ *,
d t
: 3) ISI Interval
:t
: 4) Code Edition & Addenda  
/ 98 9 A/a '4"'
: 5) Acceptance Standard El 1
: s.  
;;2
: 0) CalculatIons (See Below) 0 OK Reviewer q-Z2k J 4D OK Reviewer c,
J I
OK Reviewer 7
Z OK Roviewer 6 -
0, J=
1,0
/,p 0'. 30 e-=
9-2...
-7e-=e9. 0-32 4 '
r K 1_7 t /,/  
'/
K9.' 30 ~-_
L...es C_  
- 0
: 7) Results 0
OK Reviewer
.-1 =  
.0. 5 0 Code allowable a/t% -
C/, */
Celculated ent%
Z a) Table used (or analysts AW O< Reviower x
J J a-3S _,R I; i
fi) Was linear Interpolation used?
C) Yes 4
No If rno. why?
1 Ws A g avt itcr L mit-ng V o
ed 1
Ys
: 10) Was IWA-320z0 Signtricant Digits For Limiatingf Vniues followed?
til Yes O5 Lamninar nlw surface area: (0.75 I w) 4 No Ir no. why?
t 1) The correct Code Edition and Addenda was available and used.
O Yes Preparer  
*4 OK Reviewer J J
: 12) Statement of acceptability or rejectability with basis.
0 OK Reviewer -
J Accept I= Reject li (a/t) Code allowable > (alt) calculated C) OEM flaw evaluation handbook (see attached analysis)
CO (0/I) Code allowable.
(n/t) calculaled 13),Proppred by d P Ii g---,
12__ RI 5-Thresults are correct and the methodology used Is In accordance with applicable codes. standards. specilications end procedures.
: 14) Engineering rev w byan date 7
This review assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specincatlons nnrt procedures.
standards. specincatlons nnrt procedures.
: 15) Ap             :pydbyarilda This approval assures that al involved with this flaw sizing end lnow disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standords. specificatIons and procedures.
: 15) Ap
Adictonal - ISI Flaw       ilsposltion edal frrom Setup>
:pydbyarilda This approval assures that al involved with this flaw sizing end lnow disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standords. specificatIons and procedures.
Adictonal - ISI Flaw ilsposltion edal frrom Setup>
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                                          Report No.:                 2005VE024 Page:           4       of     7 Summary No.: 500726 Examiner: VENDOR, WESDYNE                                                     .
NM)
Level:             11           Reviewer: Jones, ThomaS                            '=,  __        _J          Date:         _______
Supplemental Report Report No.:
Examiner:              N/A                                                         Level:           N/A       Site Review: Wren, Jerry P                                        SZa             Date:             A-&
2005VE024 Page:
                                                                                                                                                                                                                          --, S Other: N/A                                                                    Level:          N/A        ANII Review: Daly, Gerald                                    ffi                 Date:         %Aut,<&sect; L)
4 of 7
Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:
N/A Other: N/A Level:
11 Reviewer: Jones, Thoma Level:
N/A Site Review: Wren, Jerry P Level:
N/A ANII Review: Daly, Gerald S
'=,
_J Date:
SZa Date:
A-&  
--, S ffi Date:  
%Aut,<&sect; L)
Comments:
Comments:
Sketch or Photo: J:\ISlData\lSl\PI2_05 outage\Scans\WeDyne Vessel Flaws\500726 N-11\Flaw Sizing 2.bmp ISI Flaw Sizing Workshicet Site/Unit:         p:   r-   1       >                                              Procedurc:                                     -r22/       Outage         No.:       PX&deg;2Z.     C F   s~ s Summary No.:                    00  e            R                                  Procedure       Rev.:                       a                             ReportNo.:           .,0OS     v     0r Workscxpe:                      a 5:r                                            Work Order No.:                 e9   D&#xa3;<             70                             Page:                 of
Sketch or Photo: J:\\ISlData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-11\\Flaw Sizing 2.bmp Site/Unit:
: 1) Flaw Number                             --                                  3)  ISI interval                            _        _  _g__    _  _  _
p:
* OK Reviewer-na,
r-1 Summary No.:
: 2) Item Number                       a       ,    90                         4) Code Edition & Addenda                       / 9q           4, ,4,7Y                 & OK Qeviewer
00 e R
: 5) Method                                                 qt   T Fl w . /VQe                  A/-        //                              (3) Flaw Sketch (See Below)                                                             O    OK Reviewer Flaw       vie_
Workscxpe:
I I
a 5:r ISI Flaw Sizing Workshicet Procedurc:  
1----..--.--.--....--                       O,-                                                      ,
-r22/
                                                                                                                                                                                            /=z ov-it         .=       O.                             9, 1,9 "
Outage No.:
4 I         Is .
PX&deg;2Z.
                                                                                            --I -g "
C F s~ s Procedure Rev.:
a                               %V
a ReportNo.:  
: 7) Calculatlons               O       OK Reviewer                 7 Show determinatIon of Surface                       o Show determination oftype oIIa                        to use Ir''-Ad6 '-C F-C               '6         s-                                 4-...#
.,0OS v 0r Work Order No.:
8)+40-FB-4 Paragraph-7cr. -                                     -f   1...I   J was used                   C    Yes      Preparer        C                    0  OK Roviewor          J
e9 D&#xa3;<
: 9) Coda Flow Dimonsions                         O   OK Revlewer9f-..J
70 Page:
_1_ O"   7         n--   -. . Z             It notmnai                                 -t tnens-rod          --      l                a _-r    .9    7          -_
of
: 10) Flow Type                                               C OK Reviewer                           _          S -          .-  .---      Ot-C      Pr 1 1) Flaw Characterizalion Figure                         O OK Reviewer                       C     j         C2      4-3          3aBrt        /
: 1) Flaw Number
: 12) riow Characterization Figure Number                                     -                      /
: 2) Item Number a
90
: 3) ISI interval
_g_ _
: 4) Code Edition & Addenda  
/ 9q 4,,4,7Y
: 5) Method qt T (3) Flaw Sketch (See Below)
Fl w. /VQe Flaw vie_
A/-
//
I 1----..--.--.--....--
O,
I it  
.=
O.
9, 1,9 "
I  
--I 4
Is.
-g "
a  
%V OK Reviewer-na,
& OK Qeviewer O
OK Reviewer ov-
/= z
: 7) Calculatlons O
OK Reviewer 7
Show determinatIon of Surface o
Show determination oftype oI Ia to use Ir'' -Ad6  
'-C F-C  
'6 s-4-...#
8)+40-FB-4 Paragraph-7cr. -
-f 1...I J was used
: 9) Coda Flow Dimonsions O OK Revlewer9f-..J
_1_
O" 7
n--  
. Z It notmnai  
-t
: 10) Flow Type C OK Reviewer 1 1) Flaw Characterizalion Figure O OK Reviewer C
j
: 12) riow Characterization Figure Number  
/
: 13) Was IWA-3300 Flaw Characterization followed?
: 13) Was IWA-3300 Flaw Characterization followed?
* Yes       0   No     If no. why?
* Yes C
: 14) The co-reut Code Edition and Addenda was availablo e nd used.                                                 41  Yes        Preparer (                                  OK Reviewer              z2-    /
Yes Preparer C
15!     re       rad   by 1a1        y iL         L ,_     *                            ,                       16) Revo                       Obv-dVt                                       -172,1/D5 The rAultS are correct and the methodology used Is In accordance                                                The rerview assures that thlr results are correct and the with upplicutble codes, standards. specincations and procedures.                                                methodology used Is In accordcance with rpplicable codes.
0 OK Roviewor J tnens-rod l
a -r
.9 7
S -
C P
Ot-r C
2 4-3 3aBrt
/
0 No If no. why?
: 14) The co-reut Code Edition and Addenda was availablo e nd used.
15!
re rad by a1 y
iL L,_
1 The rAultS are correct and the methodology used Is In accordance with upplicutble codes, standards. specincations and procedures.
Arlrt-tionaI.
SI Flew Size <ed-l fon, Sehtup 41 Yes Preparer (
OK Reviewer z2-
/
: 16)
Revo Obv-dVt  
-172,1/D5 The rerview assures that thlr results are correct and the methodology used Is In accordcance with rpplicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
Arlrt-tionaI .        SI Flew Size  <ed-l  fon, Sehtup Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NM)                                                                                                                                                            Report No.:       2005VE024 Page:       5         of     7 Summary No.: 500726 Examiner VENDOR, WESDYNE                                                 Level:       11         Reviewer: Jones, Thomas                                                 Date:           __/5 Examiner. NIA                                                            Level:     N/A       Site Review: Wren, Jerry P                                                 Date:        F_ ?:i  b; Other. NIA                                                        Level:     NIA       ANII Review: Daly, Gerald                                 J4dC~           Date: I6AL64c U
NM)
Supplemental Report Report No.:
2005VE024 Page:
5 of 7
Summary No.: 500726 Examiner VENDOR, WESDYNE Examiner. NIA Other. NIA Level:
11 Reviewer: Jones, Thomas Date:
__/5 Level:
N/A Site Review: Wren, Jerry P Level:
NIA ANII Review: Daly, Gerald J4dC~
Date:
F_ ?:i b;
Date: I6AL64c U
Comments:
Comments:
Sketch or Photo: JAISIData\ISI\PI2_05 outage\Scans\WeDyne Vessel Flaws\500726 N-1 1XFlaw Disposition 2.bmp ISI Flaw Disposition Worksheet Pi M >
Sketch or Photo: JAISIData\\ISI\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1XFlaw Disposition 2.bmp Pi M >
She/Unit:           P ZX       i                                     Procedure:       P-..ra r-             2                 pJLOutago No.:         P2            2e O Summary No.:                  5 C;)        -7.A t                      Procedure Rev.:       __                                              Report No.:     l zo-5 Ve         Od I Workscope:                                2                      Work Order No.:           O   Z'   0   (z e   7 0                         Page:             &deg;'of
She/Unit:
: 1) Flaw Number                         o;z                       3) 1SI Interval                                        -                  --    1    OK Reviewer        Ct    -
P ZX i
: 2)   Item Number               B3       . 4? 0                   A) Code   Edition   a Addenda           /7 8     g       o         AO           O    O1K Reviewer          7_
Summary No.:
: 5) Acceptance Standard                           R-       5!t $. / i             @    OK Reviewer        C____
5 C;)
6C L 4      d ti      "    _ I                        6) Calculations (See Below)                                                       O   OK Reviewor 6'2   -
-7.A t Workscope:
J~=               O-7.5 V/       -    33     3                     Vlte'     =     :2. -7 2-r     =         /7-5"7- =                            a   Z       -    15 e- "$c5       'e
2 ISI Flaw Disposition Worksheet Procedure:
                                                                                        /-     -
P-..ra r-2 pJLOutago No.:
: 7) Rusults             O OK Reviewer               ____  J
P 2 2e O Procedure Rev.:
          ?,-     . 33 3           Code allowable n/t% -             V-.V   4Za4Calculated atl% -           .2'   -7.2       Laminar naw surface area: (0.75 1 w) .                  ^/4
Report No.:
: 13) labte     used for analysis                 o     OK Reviewer'                 :Z-     e - 3   5_ I-   -I
l zo-5 Ve Od I Work Order No.:
: 9) Was linear Interpolation used?                         o Yes     O     No   It no. why?
O Z' 0 (z e 7 0 Page:  
1 ) W.3 -SC  ig i i     n Digi C-o L eF    mi    Vl e       o oJle ?         _    es                                 ce-        4-/, '/
&deg;'of
: 10) Wns IWA.3200 Significant Digits For Limiting Values followed?                               O0 Yes             O) No         It no. why?
: 1) Flaw Number o;z
: 11) The correct Coda Edition and Addenda was available end usad.                                   @ Yes         Preparer                           0   OK Reviewer         c,         J
: 2) Item Number B3. 4? 0 6
: 12) Statement of acceptability or rejectabilitywlth basis.                     O OKRoviewer -1                         /             Accept       0 Reject
C L d
              !L (alt) Codo allowable > (aft) calculated O OEM flaw evaluation handbook (see attached analysis) o (alt) Code allowable e (Wit) calculated 13teaoared bsid                crite     a           ,                                        14)  Engineering reviewby nnd date Tl 1Msults are correct end the methodology used Is In accordance                             This review assures that the results are correct and the with applicable codes. standards. specifications and procedures.                              methodology used Is In accordance with applicable codes.
4 ti I
: 3) 1SI Interval A) Code Edition a Addenda  
/7 8 g o
AO
: 5) Acceptance Standard R-5!t $. / i
: 6) Calculations (See Below) 1 OK Reviewer Ct O
O1K Reviewer 7_
@ OK Reviewer C____
O OK Reviewor 6'2 -
J~ =
O-7.5 V/
33 3
Vlte'
=
:2. -7 2-r  
=  
=
/7-5"7-a Z
15 e- "$c5  
/-  
'e
: 7) Rusults O
OK Reviewer J
?,-  
.33 3 Code allowable n/t% -
V-. V 4Za4Calculated atl% -
.2' -7.2
: 13) labte used for analysis o
OK Reviewer'
:Z-e  
- 3 5_ I-  
-I
: 9) Was linear Interpolation used?
o Yes O
No It no. why?
1 ) W.3 SC
- ig i i n Di gi C-eF o L m i V l e o Jl o e ?
es
: 10) Wns IWA.3200 Significant Digits For Limiting Values followed?
O0 Yes O)
Laminar naw surface area: (0.75 1 w).
^/4 ce -
4-/, '/
No It no. why?
: 11) The correct Coda Edition and Addenda was available end usad.  
@ Yes Preparer 0
OK Reviewer c,
J
: 12) Statement of acceptability or rejectabilitywlth basis.
O OKRoviewer  
-1  
/
Accept 0 Reject
!L (alt) Codo allowable > (aft) calculated O
OEM flaw evaluation handbook (see attached analysis) o (alt) Code allowable e (Wit) calculated 13teaoared b sid crite a
Tl 1Msults are correct end the methodology used Is In accordance with applicable codes. standards. specifications and procedures.
: 14) Engineering reviewby nnd date This review assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specifications and procedures.
standards. specifications and procedures.
1 5)   Approved by             ante           t                         _
1 5) Approved by ante t  
                          *I                         o: t'4w_w    b &deg;0-This approval assures that all Innoived with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with applicable codes. standards. specirications and procodures.
*I o: t'4w _w b &deg; 0-This approval assures that all Innoived with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with applicable codes. standards. specirications and procodures.
AOCtdtiorol - ISt Fta-       DlsPoslltin -edit tram, 5*1uP-Additional - Supplemental Reports <edit from Setup>
AOCtdtiorol - ISt Fta-DlsPoslltin -edit tram, 5*1uP-Additional - Supplemental Reports <edit from Setup>


Supplemental Report NME )                                                                                                                                                                        Report No.:                   2005VE024 Page:               6         of       7 Summary No.: 500726                                                             . t Examiner: VENDOR, WESDYNE                                                         Level:         11           Reviewer: Jones, Thoma s                                ti-        -              Date:             ___ _
NME )
Examiner: N/A                                                                      Level:        NIA       Site Review: Wren, Jerry P                                                             Date: e-S; -L(.-
Supplemental Report Report No.:
Other: NIA                                                                    Level:        N/A        ANII Review: Daly, Gerald                                    A<n
2005VE024 Page:
                                                                                                                                                                              "-1*rl Date: _67AC66r C-Comments:
6 of 7
Sketch or Photo: J:\lSlData\ISl\PI2_05 outage\Scans\WeDyne Vessel Flaws\500726 N-1 1Flaw Sizing 3.bmp ISI Flaw Sizing Workslhieet Site/Unit:       Op r         /       .                                             Procedure:         PZ-1sr-               C/-,5Z--NeOutage                       No.:       P:.2?-J         rfAtoS Summary Na.:            5C70          71      to                                  Procedure Rev.:                           O                               Report No.:               No       t VE            f Workscope:        Z      .1'      7                                          Work Order No.:               e:                 & -7     0     -                    Page:       _          of
Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:
: 1) Flaw Number                        .3                                    3) tSI lntervel                                     S   _R                           0       OK Reviewer
N/A Other: NIA t
: 2)  Item Number                B          .    'j70                        4) Code Edition & Addkanda                   / 979           34 4           .          @ OK       Reviewer           c         J
Level:
: 5) Method                                                 tf -r' A-. -        }/                                6) Flaw Sketch (See Below)                                                             Vt       OK Reviewer             c         _t Flaw View                                                                                                                                                     . q"t           .2 4       >1 0.     -/
11 Reviewer: Jones, Thoma Level:
                                                                                                                                                                          -        -P =             Z_  y   0 -I/
NIA Site Review: Wren, Jerry P Level:
                                                                                                                                                                          . ./ X M.eq I0 (a                                 1.
N/A ANII Review: Daly, Gerald s
                                                                                                                                                                        .r.'r.5> . /.o -A.-                           Z.,_-Zr..
ti-Date:
                                                                                                                                                                      /.     &'/           >a.       0(' = '.         b     ,
Date: e-S; -L(.-
I                                      I_                _ _  _    _ _                                                                                                    1.- c-e ck =.           :X i                  I          - _T CL     ;'_
Date: _67AC66r A<n
ek      =     P,       -. 5-
"-1*rl C-Comments:
: 7) Calculations               At     OK Reviewer Show determination of             Surface oiZubsufVe\
Sketch or Photo: J:\\lSlData\\ISl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1Flaw Sizing 3.bmp Site/Unit:
Show determination of type of -a'                     to use
Op r  
                              -.-- _ J    IA         s, E) 44rr-FE-4 Paragraph-7-. -                   R       -a           &#xb6;.:I   J   was used                 O Yes         Preparer                                   OK Reviewer
/
: 0) Coda Flaw Dtnmensions                       A0 OK Reviewer                   ____j___
Summary Na.:
7       --    a2           -      5_         Lt nons,7,t0     -        .2-- ._       ,  meepsured -           -    /         -      -                        -w-    -
5C70 71 to Workscope:
: 10) Flaw Type                                             CD   OK Reviewer           I                   5.
Z
S     1.         ..4,,..               P e-p   .>.
.1' 7
: 11) Flaw Characterization Figurr                           At   OK Ravlower             _        C J    Z     .o   4   _ 33            '  -    /
: 1) Flaw Number
: 12) Flaw Characterizaton Figure Number                                                         /
.3
: 2) Item Number B
'j70 ISI Flaw Sizing Workslhieet Procedure:
PZ-1sr-C/-,5Z--NeOutage No.:
P:.2?-J rfAtoS Procedure Rev.:
O Report No.:
No V
t E f
Work Order No.:
e:  
& -7 0 Page:
of
: 3) tSI lntervel S _R 0
OK Reviewer
: 4) Code Edition & Addkanda  
/ 979 34 4  
@ OK Reviewer c
J
: 5) Method tf  
-r'
: 6) Flaw Sketch (See Below)
Vt OK Reviewer c
_t Flaw View A-. -
}/
I I_
i I
- _T q"t  

.2 4
>1 0.  
-/
Z_
-P =  

y 0 -I/
../ X M. eq I 0 (a 1.
.r.'r.5 >. /.o -A.-
Z.,_-Zr..
/.  
&'/  
>a.
0(' = '.
b
: 1. - c-e ck =.
:X
CL ek
=
P,  
-.5-
: 7) Calculations At OK Reviewer Show determination of Surface oiZubsufVe\\
Show determination of type of -a' to use J
IA s,
E) 44rr-FE-4 Paragraph-7-. -
R  
-a  
&#xb6;.:I J was used O Yes Preparer OK Reviewer
: 0) Coda Flaw Dtnmensions A0 OK Reviewer
____j___
7 a2 5_
Lt nons,7,t0  
.2 --._
meepsured -
/  
-w-
: 10) Flaw Type CD OK Reviewer I
S
: 1.
: 5.
..4,,..
P e-p
: 11) Flaw Characterization Figurr At OK Ravlower J
C Z  
.o 4 _
3 3
/
: 12) Flaw Characterizaton Figure Number  
/
: 13) Was IWA-3300 Flow Charactcrizalion fotlowed?
: 13) Was IWA-3300 Flow Charactcrizalion fotlowed?
* Yes     0   No     If   no, why?
* Yes 0 No If no, why?
: 14) The correct Code Edition end Addenda was available and used.                                               e Yes        Preparer                                G0 OK RevIewer                    l7J.4
: 14) The correct Code Edition end Addenda was available and used.
        !5Pp           red   bYd             c,       ,L       --                      .7-     2-         .-        16) Revw bnnd                 dale C   _          J       C7/_-2j,                                     /p   -
!5Pp red bYd c,  
The results are correct and the methodology used Is In accordance                                            The review assures that the results are correct and the with applicable codes, standards. specifications and procedures.                                            methodology used Is In accordance with applicable codes.
,L  
.7-2-
The results are correct and the methodology used Is In accordance with applicable codes, standards. specifications and procedures.
e Yes Preparer G0 OK RevIewer l7J.4
: 16) Revw bnnd dale C
J C7/_-2j,  
/p The review assures that the results are correct and the methodology used Is In accordance with applicable codes.
standards. specifications end procedures.
standards. specifications end procedures.
Add~tienal - ISt Flws Sir* -edit Iron             r-..P~
Add~tienal - ISt Flws Sir* -edit Iron r-..P~
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMC)                                                                                                                                                                          Report No.:     2005VE024 Page:   7       of     7 Summary No.: 500726 Examiner: VENDOR, WESDYNE                                                       Level:           11         Reviewer: Jones, Thomas                                 c=r       J       Date:   ______
NMC)
Examiner: NIA                                                                  Level:         N/A       Site Review: Wren, Jerry P                                                   Date:   _ '__ __   -
Supplemental Report Report No.:
Other: NIA                                                               Level:         NIA       ANII Review: Daly, Gerald                                       9 o)
2005VE024 Page:
U-Date: I1AL,&6S Comments:
7 of 7
Sketch or Photo: J:lSIDatalSl\Pl2o05 outage\ScansNWeDyne Vessel Flaws\500726 N-1 1\Flaw Disposition 3.bmp ISI Flaw Disposition Workshect Site/Unit.         t     -:      /       ;I                                     Proceduro:     PbZ-.sl-                 As/f--             tJl-Outage     No.:   Prs Summary No.:                  5,          Oo      a. C-                        Procodure Rev.:                       C)                                   Report No.:   Voos_ VC eOJ       V Workscope:                      2-      S    :-                            Work Order No.:             4     9   O   Co te 7     0                         Page:         of
Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:
: 1) Flaw Number                             3;                            3)tSt  IInterval                            _        _    - _    __      _            q9  OK Reviewer
NIA Level:
: 2) itemi Numbar               'E     '      . C? o                       4) Code Edition & Addenda                     / F89           ./t /a   AA7             f  OK Reviewer  C        J
11 Reviewer: Jones, Thomas c=r J
: 5) Acceptance Standard                         Zt&V a-         T S / E;2                 M  OK Reviewer  e_l G) Calculations (See s3olow)                                                               7   OK Reviewer
Date:
                    ~-        O- /7S                                   e-=           17- 2)
Level:
J      -=        !V ,-7
N/A Site Review: Wren, Jerry P 9 o)
            -/Y         =- O.                                         O le,&-               /G3 g   = -5/1, = /.(Oa3 /0,                                             -:
Date: _ '__ __
                                                                                    =.       /0IO, L. 5       C--     /. C
Date: I 1AL,&6S Other: NIA Level:
: 7) Results             '  OK Reviewer                           3 n   - g 7. 2Z     0       Code allowable aft% -                     3 - 3             Calculated a/t% -         /,     6 -3       Laminar now surface area: (0.75 1 w) -
NIA ANII Review: Daly, Gerald U-Comments:
: 0) Table used for analysis                         '0,   OK Reviewer               ,J           :zr e -       3   5- t     -/
Sketch or Photo: J:lSIDatalSl\\Pl2o05 outage\\ScansNWeDyne Vessel Flaws\\500726 N-1 1\\Flaw Disposition 3.bmp Site/Unit.
: 0) Was linear interpolation used?                             C   Yes       fP No           Of no. why?
t  
i ta
/  
                                                              -AS     a Li mi in     a   ue    f O slloe dY
;I Summary No.:
: 10) Was IWA^-3200 Significant Digits For Limitling                           Values followved?             a     Yes           C)   No         If no. why?
5, O
I 1) The correct Code Edition and Addenda was available end used.                                             0     Yes       Preparer         r7_0                 C  OK Reviewer              -7
o
: 12) Statoment of acceptability or rejectability with basis.                                 0 OK Reviewer           "           J           a   Accept         0  Reject
: a.
              @ (ant) Code allowable a (alt) calcultled 0 OEM flow evaluation handbook (see attached analysis)
C-Workscope:
C) (aft) Code allowable c (alt) calculated
2-S ISI Flaw Disposition Workshect Proceduro: PbZ-.sl-As/f--
                                                  .,d.gy zv               7-IS-oS-                                 14)               a       Terin revie   _ by     and do te               .z   7     5 results are correct and the methodology used is in accordance                                    This review assures that the results are correct and the with applIcable codes. standards. specifications and procedures.                                        methodology used is In accordance with appiloble rodes.
tJl-Outage No.: Prs Procodure Rev.:
C)
Report No.:
Voos_ VC eOJ V Work Order No.:
4 9
O Co te 7 0
Page:
of
: 1) Flaw Number
: 2) itemi Numbar 3;
'E  
. C? o 3)tSt IInterval
: 4) Code Edition & Addenda  
/ F89  
./t /a AA7
: 5) Acceptance Standard Zt&V a-T S / E;2 G) Calculations (See s3olow) q9 OK Reviewer f
OK Reviewer C
J M
OK Reviewer e_l 7
OK Reviewer
~
O- / 7S J
-=  
!V,-7 e-=
17 -
2)
-/Y  
=- O.
O le,&-  
/G3 g = -5/1, = /.(Oa3 /0,  
=.
O,
/0I L. 5 C--  
/.
C
: 7) Results OK Reviewer 3
n  
- g 7. 2Z 0
Code allowable aft% -
3 - 3 Calculated a/t% -
/,
6 -3
: 0) Table used for analysis  
'0, OK Reviewer  
,J
:zr e -
3 5-t  
-/
: 0) Was linear interpolation used?
C Yes fP No Of no. why?
-AS i t a a
L i m i in a
u e f O sllo e dY
: 10) Was IWA^-3200 Significant Digits For Limitling Values followved?
a Yes C)
Laminar now surface area: (0.75 1 w) -
No If no. why?
I 1) The correct Code Edition and Addenda was available end used.
0 Yes Preparer r7_0
: 12) Statoment of acceptability or rejectability with basis.
0 OK Reviewer "
J a
Accept
@ (ant) Code allowable a (alt) calcultled 0
OEM flow evaluation handbook (see attached analysis)
C) (aft) Code allowable c (alt) calculated C OK Reviewer
-7 0
Reject
.,d.gy zv 7-IS-oS-results are correct and the methodology used is in accordance with applIcable codes. standards. specifications and procedures.
: 14) a Terin revie by and do te  
.z 7
5 This review assures that the results are correct and the methodology used is In accordance with appiloble rodes.
standards. specifications and procedures.
standards. specifications and procedures.
: 15)     Ap roved bynd         dtol
: 15) Ap roved bynd dtol
              /O         -          -. _. -1                     t nsl1 approval assures thatie involved with this law sizing and naw disposition were aware oo the necessity that the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.
/O  
Addt.t.l       - ISO Fla- DO,.posillo,, '-dil         from Saluo4 Additional - Supplemental Reports <edit from Setup>
-1 t
nsl1 approval assures thatie involved with this law sizing and naw disposition were aware oo the necessity that the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.
Addt.t.l  
- ISO Fla-DO,.posillo,, '-dil from Saluo4 Additional - Supplemental Reports <edit from Setup>


REACTOR VESSEL WELD RESULTS  
REACTOR VESSEL WELD RESULTS  


==SUMMARY==
==SUMMARY==
 
PLANT NAME Prairie Island Unit 2
PLANT NAME                     Prairie Island         Unit                         2 WELD NO.                 Ni1 (500726)       COMPONENT             Safety Injection Noz-Shell @ 288.50 LIMITATIONS:           NO Fj                 YES [I                 59.26 % Complete See Coverage Breakdown Sheet RESULTS                                       NO. OF INDICATIONS             3 NI                                         STATUS                     Code Allowable RI           X EXAM DOCUMENTATION                     INDICATION DOCUMENTATION
WELD NO.
[!JPARAGON ANALYSIS LOG                                 EXIASSESSMENT SHEET WE1PARAGON ACQUISITION LOG                             E-7IPARAGON HARD COPY 3Fl SCAN PRINT OUT                                   [=IOTHER (Specify)
Ni1 (500726)
COMPONENT Safety Injection Noz-Shell @ 288.50 LIMITATIONS:
NO Fj YES [I 59.26 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 3
NI STATUS Code Allowable RI X
EXAM DOCUMENTATION INDICATION DOCUMENTATION
[!JPARAGON ANALYSIS LOG EXIASSESSMENT SHEET WE1PARAGON ACQUISITION LOG E-7IPARAGON HARD COPY 3Fl SCAN PRINT OUT
[=IOTHER (Specify)
WCOVERAGE BREAKDOWN Comments:
WCOVERAGE BREAKDOWN Comments:
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Analyst                       Date:
Analyst Date:


R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME                        Prairie Island WesDyne WELD NO.                           N11 (500726)
PLANT NAME R.V. COVERAGE ESTIMATE BREAKDOWNS Prairie Island WesDyne WELD NO.
International COMPONENT         Safety Injection Noz-Shell @ 288.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION                 45 Shear               45 L Single             45 L Dual     Combined Bore/Star WELD VOLUME l WELD lVOLUME                       WELD IVOLUME l WELD lVOLUME TAN Scan             l         l           lllll Parallel             15.55       57.14         0.00     53.66       0.00     28.10 l         ll Combined Bore&Star                                                                                     ;
N11 (500726)
Perpendicular                                                                                 97.40     88.15 AVERAGE                       36.35                     26.83                 14.05               92.78 Comments:      Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).
International COMPONENT Safety Injection Noz-Shell @ 288.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD VOLUME l WELD lVOLUME WELD IVOLUME l WELD lVOLUME TAN Scan l
l lllll Parallel 15.55 57.14 0.00 53.66 0.00 28.10 l ll Combined Bore&Star Perpendicular 97.40 88.15 AVERAGE 36.35 26.83 14.05 92.78 Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, Comments:
and the Tan Scan (parallel).
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.
Combined Perp.             92.78             Combined Para.                 25.74         Combined Average         59.26
Combined Perp.
                                      .      AA        In Analyst                -1      f          e                                              Date    */) 5kS
Analyst 92.78 Combined Para.
AA In
-1 f
e 25.74 Combined Average 59.26 Date
*/) 5kS


Figure 1 Tan Coverage Illustration of the Safety In jection Nozzle
Figure 1 Tan Coverage Illustration of the Safety In jection Nozzle


REV. TRF.O4- 0o 1 8 NORTH
REV.
                                                            #22 STEAM GENERATOR CONT ON DWG 2-ISI-33C l
TRF.O 4-0o 1 8 NORTH
#22 STEAM GENERATOR CONT ON DWG 2-ISI-33C l
CONT ON DWG 2-ISI-33B CONT ON DWG 2-IS1-31 so.
CONT ON DWG 2-ISI-33B CONT ON DWG 2-IS1-31 so.
CONT ON DWG 2-ISI-19 ON DWG 1-20A WELD   5   DETAIL WELD   1 DETAIL
CONT ON DWG 2-ISI-19 ON DWG 1-20A WELD 5 DETAIL WELD 1 DETAIL WEST
                                                                                      = WELD NO.
= WELD NO.
REACTOR COOLANT LOOP //B //               XH-1 001-388            WEST XH-1 001 -1182 REF: XH-1 106-7028       IFILE NO:2133ARO1 NS'P(M&SP)-PI-2                             sd' l:-
REACTOR COOLANT LOOP
DWN: DMN         CHKD k , B     APPD: Y6MUjt SYSTEM:REACTOR COOLANT LINE: 29 2RC-1B IDWG:             2-ISI-33AI             REV: 02
//B //
XH-1 XH-1 REF: XH-1 001-388 001 -1182 106-7028 IFILE NO:2133ARO1 NS'P(M&SP)-PI-2 l:-
sd' DWN: DMN CHKD k, B APPD: Y6MUjt SYSTEM:REACTOR COOLANT LINE: 29 2RC-1B IDWG:
2-ISI-33AI REV: 02


UT Pipe Weld Examination N)
N)
Site/Unit:   PINGP /             P12                                       Procedure:         SWI NDE-UT-11                     Outage No.:         E031 Summary No.:                  501137                                        Procedure Rev.:                0                          Report No.:       2005U036 Workscope:                      [SI                                        Work Order No.:            0406678                              Page:   1     of     5 Code:                       1989 Edition                           Cat./ltem:         B-F/B5.70                 Location:                     Containment Drawing No.:                             2-ISI-33A                            
Site/Unit:
PINGP /
Summary No.:
Workscope:
UT Pipe Weld Examination P12 501137
[SI Procedure:
Procedure Rev.:
Work Order No.:
SWI NDE-UT-11 0
0406678 Outage No.:
E031 Report No.:
2005U036 Page:
1 of 5
Code:
1989 Edition Cat./ltem:
B-F/B5.70 Location:
Containment Drawing No.:
2-ISI-33A  


== Description:==
==
50 Red Elbow-Nozzle System ID:         RC Component ID: W- 5                                                                                           Size/Length:     2.0"/110"       Thickness/Diameter:     2.9"/29"ID Limitations:       See Supplements                                                                                       StartTime:     15:20         Finish Time:     16:08 Examination Surface:           Inside M           Outside i                   Surface Condition: Blended Lo Location:                     TDC                   Wo Location:         Centerline of Weld           Couplant:         Sonotrace 40           Batch No.:       #02243 Temp. Tool Mfg.:             PTC Instruments               Serial No.:               P11l               Surface Temp.:         86     *F Cal. Report No.:                                     2005CA034, 2005CA035, 2005CA036 AngleUsed               0       45 1 45T 1 60             N/A   l   N/A Scanning dB         42.0     84.0   80.0     N/A       NIA         N/A Indication(s):     Yes D         No i                                   Scan Coverage:   Upstream i     Downstream   a       CW Ri     CCW i Comments:
Description:==
Scanned at reference due to excessive noise @ +6 dB. 0&deg; exam performed by J. Timm - Exam start 00:23, exam end 04:00 on 5123105 Results:           NAD   i           IND   a           GEO                   _
50 Red Elbow-Nozzle System ID:
Percent Of Coverage Obtained > 90%:                     No                   Reviewed Previous Data:             Yes Examiner         Level Ill                             Signature                         Date Reviewer                                     Signature                         Date Blechinger, Todd P.                                                                 512212005   Hailing, David A.
RC Component ID: W-5 Size/Length:
Examiner         Level II                             Signature                         Date Site Review                                   Signature                         Date Timm, Jeremy T.                                                                     5/23/2005   Wren, Jerry Other             Level N/A                             Signature                         Date ANII Review                                   Signature                         Date N/A                                                                                             Daly, Gerald
2.0"/110" Thickness/Diameter:
2.9"/29"ID Limitations:
See Supplements StartTime:
15:20 Finish Time:
16:08 Examination Surface:
Inside M Outside i Surface Condition: Blended Lo Location:
TDC Wo Location:
Centerline of Weld Couplant:
Sonotrace 40 Batch No.:  
#02243 Temp. Tool Mfg.:
PTC Instruments Serial No.:
P11l Surface Temp.:
86  
*F Cal. Report No.:
2005CA034, 2005CA035, 2005CA036 AngleUsed 0
45 1 45T 1 60 N/A l
N/A Scanning dB 42.0 84.0 80.0 N/A NIA N/A Indication(s):
Yes D No i Scan Coverage:
Upstream i Downstream a CW Ri CCW i Comments:
Scanned at reference due to excessive noise @ +6 dB. 0&deg; exam performed by J. Timm - Exam start 00:23, exam end 04:00 on 5123105 Results:
NAD i IND a GEO Percent Of Coverage Obtained > 90%:
No Reviewed Previous Data:
Yes Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.
512212005 Hailing, David A.
Examiner Level II Signature Date Site Review Signature Date Timm, Jeremy T.
5/23/2005 Wren, Jerry Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald


NM).. ,.
NM) 0
0
`0 -
        `0 -   O Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:   PINGP /           P12                       Procedure:       SWI NDE-UT-11         Outage No.:         E031 Summary No.:                 501137                      Procedure Rev.:                 0            Report No.:     2005U036 Workscope:                    ISI                        Work Order No.:            0406678                Page:     2     of     5 45 deg Scan 1       100.000         % LengthX        100.000       % volume of length / 100 =  100.000     % total for Scan I Scan 2          0.000         % LengthX          0.000       % volume of length / 100 =   0.000      % total for Scan 2 Scan 3        100.000        % Length X        67.690      % volume of length / 100 =   67.690       % total for Scan 3 Scan 4        100.000        % Length X        67.690      % volume of length / 100 =  67.690      % total for Scan 4 Add totals and divide by # scans =           78.460   % total for 45 deg Other de- -               .    (to be used for supplemental scans)
O Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:
PINGP /
P12 Summary No.:
501137 Workscope:
ISI Procedure:
SWI NDE-UT-11 Procedure Rev.:
0 Work Order No.:
0406678 Outage No.:
E031 Report No.:
2005U036 Page:
2 of 5
45 deg Scan 1 Scan 2 Scan 3 Scan 4 100.000 0.000 100.000 100.000
% LengthX
% LengthX
% Length X
% Length X 100.000 0.000 67.690 67.690
% volume of length / 100 =
% volume of length / 100 =
% volume of length / 100 =
% volume of length / 100 =
100.000 0.000 67.690 67.690
% total for Scan I
% total for Scan 2
% total for Scan 3
% total for Scan 4 Add totals and divide by # scans =
78.460  
% total for 45 deg Other de- -
(to be used for supplemental scans)
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
Scan 1                         % LengthX                       % volume of length / 100 =               % total for Scan 1 Scan 2                          % LengthX                      % volume of length / 100 =               % total for Scan 2 Scan 3                          % LengthX                      % volume of length / 100 =               % total for Scan 3 Scan 4                          % LengthX                      % volume of length / 100 =                % total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 78.460     % Total for complete exam Site Field Supervisor                                                               Date:
Scan 1 Scan 2 Scan 3 Scan 4
% LengthX
% LengthX
% LengthX
% LengthX
% volume of length / 100 =
% volume of length / 100 =
% volume of length / 100 =
% volume of length / 100 =
% total for Scan 1
% total for Scan 2
% total for Scan 3
% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 78.460  
% Total for complete exam Site Field Supervisor Date:
Additional - Calculation Pipe <edit from Setup>
Additional - Calculation Pipe <edit from Setup>


Supplemental Report Report No.:     2005U036 Page:     3     of   5 Summary No.: 501137 Examiner: Blechinger, Todd P.                       Level: Ill         Reviewer Halling, David A.             Date:
Supplemental Report Report No.:
Examiner: Timm, Jeremy T.                           Level: Ill   Site Review: Wren, Jerry                     Date:
2005U036 Page:
Other: NIA                                     Level: NIA   ANII Review: Daly, Gerald                     Date:
3 of 5
Comments: W-5 Coverage Plot Sketch or Photo: J:\lSIData\lSI\Pl2_05 outage\Scans\2005U036 501137 coverage plot.jpg
Summary No.: 501137 Examiner: Blechinger, Todd P.
                                                                                                          ~~~~~~~~~~&1-   :- :,.: . -.-: .--:
Level:
                                              .:. '- ' ~/..         . I .'   , '..... -. ,."
Ill Reviewer Halling, David A.
Date:
Examiner: Timm, Jeremy T.
Level:
Ill Site Review: Wren, Jerry Date:
Other: NIA Level:
NIA ANII Review: Daly, Gerald Date:
Comments: W-5 Coverage Plot Sketch or Photo: J:\\lSIData\\lSI\\Pl2_05 outage\\Scans\\2005U036 501137 coverage plot.jpg
~~~~~~~~~~&1- :- :,.:. -.-:.--:
'- ' ~/..
I.'
Additional - Supplemental Reports <edit frm Setup>
Additional - Supplemental Reports <edit frm Setup>


  ..,. .7.:
..,..7.:
Supplemental Report NMP-                                                                                                Report No.:     2005U036 Page:     4    of  5 Summary No.: 501137 Examiner: Blechinger, Todd P.               Level:   IlIl       Reviewer. Hailing, David A.             Date:
NMP-Supplemental Report Report No.:
Examiner: Timm, Jeremy T.                    Level:   IlIl   Site Review: Wren, Jerry                   Date:
Page:
Other NIA                             Level:  NIA    ANII Review: Daly, Gerald                   Date:
Summary No.: 501137 Examiner: Blechinger, Todd P.
Comments: Limitation sketch W-5. No scans on nozzle side due to configuration.
Examiner: Timm, Jeremy T.
Sketch or Photo: J:AISIData\ISI\P12_05 outage\Scans\2005U036 Limitation Sketchjpg W.*.
Other NIA 2005U036 4
PKi .    ->
of 5
i ;    ;edr .
Date:
Date:
Date:
Level:
IlIl Reviewer. Hailing, David A.
Level:
IlIl Site Review: Wren, Jerry Level:
NIA ANII Review: Daly, Gerald Comments: Limitation sketch W-5. No scans on nozzle side due to configuration.
Sketch or Photo: J:AISIData\\ISI\\P12_05 outage\\Scans\\2005U036 Limitation Sketchjpg W.
PKi  
;edr i
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMC)                                                                                            Report No.:     2005U036 Page:     5    of  5 Summary No.: 501137 Examiner: Blechinger, Todd P.                 Level: Ill     Reviewer: Halling, David A.             Date:
NMC)
Examiner: Timm, Jeremy T.                      Level: Ill   Site Review: Wren, Jerry                   Date:
Supplemental Report Report No.:
Other: N/A                                 Level: N/A  ANII Review: Daly, Gerald                   Date:
Page:
Comments: W-5 Limitation Photo SketchorPhoto: J:\ISIData\ISIXP12 05outage\Photos\TODD\5-25\DSCO1640.JPG Additional - Supplemental Reports <edit from Setup>
Summary No.: 501137 Examiner: Blechinger, Todd P.
Examiner: Timm, Jeremy T.
Other: N/A 2005U036 5
of 5
Date:
Date:
Date:
Level:
Ill Reviewer: Halling, David A.
Level:
Ill Site Review: Wren, Jerry Level:
N/A ANII Review: Daly, Gerald Comments: W-5 Limitation Photo SketchorPhoto:
J:\\ISIData\\ISIXP12 05outage\\Photos\\TODD\\5-25\\DSCO1640.JPG Additional - Supplemental Reports <edit from Setup>


                    .Mmv. H.U4-l NORTH 1/4" CONT ON DWG 2-ISI-10B EL. 699'-O as   EL. 718'-9 5/8" INTEGRAL ATTACHMENT
.Mmv.
                                                                                    = HANGER NO.
H.U4-l CONT ON DWG 2-ISI-10B EL. 699'-O 1/4" as EL. 718'-9 5/8" NORTH INTEGRAL ATTACHMENT WES 0
                                                                                    = WELD NO.
I EL1
WES 0    = BOLT NO.
= HANGER NO.
IEL1  = VALVE NO.
= WELD NO.
REF: XH-1 106-2550       IFILE NO:2110AR05 8" RHR TAKEOFF LOOP "A" HOT LEG           1\S(   MSP)-P1-2                           I S.I DWN: CADWorksCHKD: UL-       APPD:     9, SYSTEM:RHR TAKEOFF L INE: 8-2RH-lA. 8-2RC-15A
= BOLT NO.
_DWG:           2-ISI-10A             IREV: 06
= VALVE NO.
REF: XH-1 106-2550 IFILE NO:2110AR05 8" RHR TAKEOFF LOOP "A" HOT LEG 1\\S(
MSP)-P1-2 I S.I DWN: CADWorksCHKD: UL-APPD:
9, SYSTEM:RHR TAKEOFF L INE: 8-2RH-lA. 8-2RC-15A
_DWG:
2-ISI-10A IREV: 06


UT Pipe Weld Examination
'MC >
      'MC>
Site/Unit:
Site/Unit:     PINGP /           P12                                       Procedure:       SWI NDE-UT-16A                     Outage No.:         E031 Summary No.:                   501953                                       Procedure Rev.:                1                           Report No.:      2005U024 Workscope:                     ISI                                     Work Order No.:               0406678                             Page:   1     of     5 Code:                         1989 Edition                         Cat./ltem:         B-J/B9.11                   Location:                     Containment Drawing No.:                             2-ISI-10A                            
PINGP /
Summary No.:
UT Pipe Weld Examination P12 Procedure:
Procedure Rev.:
SWI NDE-UT-16A Outage No.:
E031 Report No.:
2005U024 501953 1
Workscope:
ISI Work Order No.:
0406678 Page:
1 of 5
Code:
1989 Edition Cat./ltem:
B-J/B9.11 Location:
Containment Drawing No.:
2-ISI-10A  


== Description:==
==
Valve to Pipe System ID:         RH Component ID: W-11                                                                                           Size/Length:       .9" /27"       Thickness/Diameter:     .812" /8" Limitations:       See Supplements                                                                                       Start Time:     14:20         Finish Time:       14:40 Examination Surface:           Inside E         Outside i                   Surface Condition: Flat Topped Lo Location:                     TDC                   Wo Location:         Centerline of Weld           Couplant:         Sonotrace 40         Batch No.:         #02243 Temp. Tool Mfg.:             PTC Instruments             Serial No.:               Pill                 Surface Temp.:         71   &deg;F Cal. Report No.:                                   2005CA025, 2005CA026, 2005CA027 Angle Used             0       45     45T     60     60 RL l     NIA Scanning dB         NIA       36.0   36.0   43.0     59.0       N/A Indication(s):     Yes   El     No i                                   Scan Coverage:   Upstream E     Downstream   ia       CW i     CCW i Comments:
Description:==
Valve to Pipe System ID:
RH Component ID: W-11 Size/Length:  
.9" /27" Thickness/Diameter:  
.812" /8" Limitations:
See Supplements Start Time:
14:20 Finish Time:
14:40 Examination Surface:
Inside E Outside i Surface Condition: Flat Topped Lo Location:
TDC Wo Location:
Centerline of Weld Couplant:
Sonotrace 40 Batch No.:  
#02243 Temp. Tool Mfg.:
PTC Instruments Serial No.:
Pill Surface Temp.:
71  
&deg;F Cal. Report No.:
2005CA025, 2005CA026, 2005CA027 Angle Used 0
45 45T 60 60 RL l NIA Scanning dB NIA 36.0 36.0 43.0 59.0 N/A Indication(s):
Yes El No i Scan Coverage:
Upstream E Downstream ia CW i CCW i Comments:
Single sided exam - exam performed through 100% of code volume, however procedure not qualified for detection on far side. Best effort exam on far side volume.
Single sided exam - exam performed through 100% of code volume, however procedure not qualified for detection on far side. Best effort exam on far side volume.
No scans on valve side due to configuration.
No scans on valve side due to configuration.
Results:           NAD     i         IND []           GEO   C Percent Of Coverage Obtained > 90%:                     No                 Reviewed Previous Data:             N/A Examiner         Level Ill                           Signature                         Date Reviewer                                     Signature                           Date Blechinger, Todd P.                                                                 5/19/2005   Hailing, David A.                                                             5/23/2005 Examiner         Level II                             Signature                         Date Site Review                                   Signature                           Date Jensen, Arlen                                                                       5/19/2005   Wren, Jerry                                                                   5/2412005 Other             Level N/A                           Signature                         Date ANII Review                                   Signature                           Date N/A                                                                                           Daly, Gerald                                                                 5/27/2005
Results:
NAD i IND []
GEO C Percent Of Coverage Obtained > 90%:
No Reviewed Previous Data:
N/A Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.
5/19/2005 Hailing, David A.
5/23/2005 Examiner Level II Signature Date Site Review Signature Date Jensen, Arlen 5/19/2005 Wren, Jerry 5/2412005 Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald 5/27/2005


Determination of Percent Coverage for NM7I) aN.M UT Examinations - Pipe Site/Unit:   PINGP /           P12                       Procedure:     SWI NDE-UT-16A       Outage No.:         E031 Summary No.:                  501953                        Procedure Rev.:                1            Report No.:     2005U024 Workscope:                    ISI                        Work Order No.:            0406678              Page:     2     of   5 45 den Scan 1           88.920       % Length X         44.460       % volume of length / 100 =  39.534      % total for Scan 1 Scan 2         88.920         % Length X         44.460       % volume of length / 100 =  39.534      % total for Scan 2 Scan 3          100.000       % Length X         50.000       % volume of length / 100 =   50.000      % total for Scan 3 Scan 4          100.000        % Length X        50.000       % volume of length /100 =    50.000     % total for Scan 4 Add totals and divide by # scans =         44.767     % total for 45 deg Other deg -         .      .    (to be used for supplemental scans)
NM7I) aN.M Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:
PINGP /
P12 Summary No.:
501953 Workscope:
ISI Procedure:
Procedure Rev.:
Work Order No.:
SWI NDE-UT-16A 1
0406678 Outage No.:
E031 Report No.:
2005U024 Page:
2 of 5
45 den Scan 1 88.920  
% Length X 44.460 Scan 2 88.920  
% Length X 44.460 Scan 3 100.000
% Length X 50.000 Scan 4 100.000  
% Length X 50.000
% volume of length / 100 =
% volume of length / 100 =
% volume of length / 100 =
% volume of length /100 =
39.534
% total for Scan 1 39.534
% total for Scan 2 50.000  
% total for Scan 3 50.000  
% total for Scan 4 Add totals and divide by # scans =
44.767  
% total for 45 deg Other deg -
(to be used for supplemental scans)
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
Scan I                           % LengthX                       % volume of length /100 =               % total for Scan 1 Scan 2                          % LengthX                      % volume of length /100 =               % total for Scan 2 Scan 3                          % LengthX                      % volume of length / 100 =               % total for Scan 3 Scan 4                          % LengthX                      % volume of length / 100 =              % total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 44.767       % Total for complete exam Site Field Supervisor                                                               Date:
Scan I Scan 2 Scan 3 Scan 4
% LengthX
% LengthX
% LengthX
% LengthX
% volume of length /100 =
% volume of length /100 =
% volume of length / 100 =
% volume of length / 100 =
% total for Scan 1
% total for Scan 2
% total for Scan 3
% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 44.767  
% Total for complete exam Site Field Supervisor Date:
Additional - Calculation Pipe <edit from Setup>
Additional - Calculation Pipe <edit from Setup>


Am, ,Supplemental                                                         Report Report No.:     2005U024 Page:     3   of   5 Summary No.: 501953 Examiner Blechinger, Todd P.                             Level: Ill     Reviewer Halling, David A.               Date:  5/2312005 Date:  512412005 Examiner. Jensen, Arlen                                  Level: 11   Site Review: Wren, Jerry Date:  5/27/2005 Other: N/A                                          Level: N/A   ANII Review: Daly, Gerald Comments: W-11 coverage plot Sketch or Photo: J:lSIData\ISI\P12_05 outage\Scans\2005UO24 501953 coverage plot.jpg L.    ..
Am,,Supplemental Report Report No.:
IH-          1.
2005U024 Page:
                                                                                          -. H.-.
3 of 5
b .... ... .. . L. . - ... .. .                        -
Summary No.: 501953 Examiner Blechinger, Todd P.
                                                                                                                                                      ...I....r Additional - Supplemental Reports <edit from Setup>
Examiner. Jensen, Arlen Other: N/A Level:
Ill Reviewer Halling, David A.
Level:
11 Site Review: Wren, Jerry Level:
N/A ANII Review: Daly, Gerald Date:
5/2312005 Date:
512412005 Date:
5/27/2005 Comments: W-11 coverage plot Sketch or Photo: J:lSIData\\ISI\\P12_05 outage\\Scans\\2005UO24 501953 coverage plot.jpg L.
b.......  
. L.
IH-
: 1. -...
H.-. -
...I....r Additional - Supplemental Reports <edit from Setup>


N
N -)
  -)                                               Supplemental Report Report No.:     2005U024 Page:     4    of    5 Summary No.: 501953 Examiner: Blechinger, Todd P.                   Level:   IlIl         Reviewer: Hailing, David A.               Date: 5/2312005 Examiner: Jensen, Arlen                        Level:   II       Site Review: Wren, Jerry                     Date: 5124/2005 Other: NIA                                Level: NA       ANII Review: Daly, Gerald                     Date:  5/27/2005 Comments:     No upstream exams due to valve body taper. Integral attachment limits downstream exam @ 2700 for 3".
Supplemental Report Report No.:
Sketch or Photo: J:%lSlData\lSI\Pl2_05 outage\Scans\2005U024 501953 limitation diagram.jpg
Page:
                                                                    ,. 0
Summary No.: 501953 Examiner: Blechinger, Todd P.
                                                                  .:0 3-?".-V ...
Examiner: Jensen, Arlen Other: NIA 2005U024 4
PA',. ,:',
of 5
                              ,I 1 - .      .
Date:
5/2312005 Date:
5124/2005 Date:
5/27/2005 Level:
IlIl Reviewer: Hailing, David A.
Level:
II Site Review: Wren, Jerry Level:
NA ANII Review: Daly, Gerald Comments:
No upstream exams due to valve body taper. Integral attachment limits downstream exam @ 2700 for 3".
Sketch or Photo: J:%lSlData\\lSI\\Pl2_05 outage\\Scans\\2005U024 501953 limitation diagram.jpg
,. 0
.: 0 3-?".-V...
PA',.,: ',
,I 1.
Additional - Supplemental Reports <edit from Setup>
Additional - Supplemental Reports <edit from Setup>


Supplemental Report NMl6)                                                                                              Report No.:     2005U024 Page:     5    of    5 Summary No.: 501953 Examiner: Blechinger, Todd P.                   Level:   Ill     Reviewer: Halling, David A.               Date:  5123/2005 Examiner: Jensen, Arlen                        Level:   II   Site Review: Wren, Jerry       .
NMl6)
Date:  5124/2005 Other:  N/A                              Level: N/A   ANII Review: Daly, Gerald                   Date:  5/27/2005 Comments: W-11 limitation photo Sketch or Photo: J:lSIData\ISI\P12 05 outage\Photos\TODD\5-19\DSCO1549.JPG Additional - Supplemental Reports <edit from Setup>
Supplemental Report Report No.:
Page:
Summary No.: 501953 Examiner: Blechinger, Todd P.
Examiner: Jensen, Arlen Other:
N/A 2005U024 5
of 5
Date:
5123/2005 Date:
5124/2005 Date:
5/27/2005 Level:
Ill Reviewer: Halling, David A.
Level:
II Site Review: Wren, Jerry Level:
N/A ANII Review: Daly, Gerald Comments: W-11 limitation photo Sketch or Photo:
J:lSIData\\ISI\\P12 05 outage\\Photos\\TODD\\5-19\\DSCO1549.JPG Additional - Supplemental Reports <edit from Setup>


flE'V'A TRF 4-018 NORT
flE'V'A TRF 4-018 NORT
                                                  \ t, /7 INTEGRAL ATTACHMENT
\\
                                                          = HANGER
t,  
                                                *3L 7ST7    = WELD NO.
/ 7 INTEGRAL ATTACHMENT
M)                   REF:XH-1 106-48         IFILE NO:2147BRO4 I
= HANGER
cU)
= WELD NO.
ISP(M&sp-PI-2                             ISI DWN: DMN       CHKD:LC o     APPD:
*3L 7ST7 M)
l                    SYSTEM:MAIN STEAM co                    LINE: 6-2MS-2. 30-2MS-2. 31-2MS-2 DWG:           2-ISI-47B           IREV: 05
I cU) l co REF:XH-1 106-48 IFILE NO:2147BRO4 ISP(M&sp-PI-2 ISI DWN: DMN CHKD:LC o APPD:
SYSTEM:MAIN STEAM LINE: 6-2MS-2. 30-2MS-2.
31-2MS-2 DWG:
2-ISI-47B IREV: 05


UT Pipe Weld Examination NMC-Site/Unit:   PINGP /             P12                                       Procedure:         SWI NDE-UT-1A                     Outage No.:         E031 Summary No.:                  500814                                      Procedure Rev.:                1                          Report No.:       2005U023 Workscope:                    [Si                                      Work Order No.:              0406679                              Page:     1     of     4 Code:                       1989 EditIon                         Cat./item:         C-F-21C5.80                 Location:                       Aux Bldg Drawing No.:                             2-ISI-47B                            
NMC-Site/Unit:
PINGP /
Summary No.:
Workscope:
UT Pipe Weld Examination P12 500814
[Si Procedure:
Procedure Rev.:
Work Order No.:
SWI NDE-UT-1A 1
0406679 Outage No.:
E031 Report No.:
2005U023 Page:
1 of 4
Code:
1989 EditIon Cat./item:
C-F-21C5.80 Location:
Aux Bldg Drawing No.:
2-ISI-47B  


== Description:==
==
Tee to Flange System ID:         MS Component ID: W-14ILSU                                                                                     Size/Length:       1.8" /68"     Thickness/Diameter:     1.75" I N/A Limitations:       See supplements                                                                                     Start Time:     10:15         Finish Time:       10:30 Examination Surface:           Inside E         Outside i                   Surface Condition: Ground Flush Lo Location:               TDC East Side               Wo Location:         Centerline of Weld           Couplant:         Sonotrace 40         Batch No.:         #02243 Temp. Tool Mfg.:           PTC Instruments               Serial No.:             P111                 Surface Temp.:         62   &#xb6;F Cal. Report No.:                                         2005CA021, 2005CA022 Angle Used             0     45     45T       60       N/A       N/A Scanning dB         N/A l44.0         44.0   48.0     NIA       NIA Indication(s):     Yes El       No 0                                 Scan Coverage:   Upstream i     Downstream n           CW R     CCW i Comments:
Description:==
Tee to Flange System ID:
MS Component ID: W-14ILSU Size/Length:
1.8" /68" Thickness/Diameter:
1.75" I N/A Limitations:
See supplements Start Time:
10:15 Finish Time:
10:30 Examination Surface:
Inside E Outside i Surface Condition: Ground Flush Lo Location:
TDC East Side Wo Location:
Centerline of Weld Couplant:
Sonotrace 40 Batch No.:  
#02243 Temp. Tool Mfg.:
PTC Instruments Serial No.:
P111 Surface Temp.:
62  
&#xb6;F Cal. Report No.:
2005CA021, 2005CA022 Angle Used 0
45 45T 60 N/A N/A Scanning dB N/A l44.0 44.0 48.0 NIA NIA Indication(s):
Yes El No 0 Scan Coverage:
Upstream i Downstream n CW R CCW i Comments:
No downstream scan on flange side due to configuration.
No downstream scan on flange side due to configuration.
Results:           NAD Ej           IND   El         GEO   a_
Results:
Percent Of Coverage Obtained > 90%:                     No                 Reviewed Previous Data:             Yes Examiner         Level Ill                           Signature                         Date Reviewer                                     Signature                           Date Blechinger, Todd P.                                                               5117/2005   Tlmm, Jeremy                                                                 5/25/2005 Examiner         Level Il                           Signature                         Date Site Review                                   Signature                           Date Jensen, Arlen                                                                     5/17/2005   Wren, Jerry                                                                   512512005 Other             Level N/A                           Signature                         Date ANII Review                                   Signature                           Date N/A                                                                                           Daly, Gerald                                                                 6121/2005
NAD Ej IND El GEO a_
Percent Of Coverage Obtained > 90%:
No Reviewed Previous Data:
Yes Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.
5117/2005 Tlmm, Jeremy 5/25/2005 Examiner Level Il Signature Date Site Review Signature Date Jensen, Arlen 5/17/2005 Wren, Jerry 512512005 Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald 6121/2005


. .. .7 ..
....7..
Determination of Percent Coverage for Nmr,,-                                                        UT Examinations - Pipe Site/Unit:   PINGP     /     P12                       Procedure:       SWI NDE-UT-IA           Outage No.:         E031 Summary No.:                      500814                      Procedure Rev.:                1              Report No.:     2005U023 Workscope:                        ISI                      Work Order No.:            0406679                  Page:     2     of   4 45 deg Scan 1         52.900       % Length X         100.000     % volume of length / 100 =      52.900      % total for Scan 1 Scan 2        52.900        % LengthX          100.000     % volume of length /100 =       52.900      % total for Scan 2 Scan 3        100.000        % Length X        96.800      % volume of length /100 =       96.800      % total for Scan 3 Scan 4        100.000        % LengthX          96.800       % volume of length / 100 =      96.800     % total for Scan 4 Add totals and divide by # scans =         74.850   % total for 45 deg Other deg -         .      .  (to be used for supplemental scans)
Nmr,,-
Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:
PINGP /
P12 Summary No.:
500814 Workscope:
ISI Procedure:
Procedure Rev.:
Work Order No.:
SWI NDE-UT-IA 1
0406679 Outage No.:
E031 Report No.:
2005U023 Page:
2 of 4
45 deg Scan 1 Scan 2 Scan 3 Scan 4 52.900  
% Length X 52.900
% LengthX 100.000  
% Length X 100.000
% LengthX 100.000 100.000 96.800 96.800
% volume of length / 100 =
% volume of length /100 =
% volume of length /100 =
% volume of length / 100 =
52.900
% total for Scan 1 52.900
% total for Scan 2 96.800  
% total for Scan 3 96.800  
% total for Scan 4 Add totals and divide by # scans =
74.850  
% total for 45 deg Other deg -
(to be used for supplemental scans)
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
Scan I                         % LengthX                       % volume of length / 100 =                 % total for Scan 1 Scan 2                        % LengthX                      % volume of length /100 =                   % total for Scan 2 Scan 3                        % LengthX                      % volume of length / 100 = _%                total for Scan 3 Scan 4                        % LengthX                      % volume of length / 100 =                 % total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 74.850     % Total for complete exam Site Field Supervisor:                                                             Date:
Scan I Scan 2 Scan 3 Scan 4
% LengthX
% LengthX
% LengthX
% LengthX
% volume of length / 100 =
% volume of length /100 =
% volume of length / 100 =
% volume of length / 100 =
% total for Scan 1
% total for Scan 2 total for Scan 3
% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 74.850  
% Total for complete exam Site Field Supervisor:
Date:
Additional - Calculation Pipe <edit from Setup>
Additional - Calculation Pipe <edit from Setup>


Supplemental Report Report No.:     2005U023 Page:     3     of   4 Summary No.: 500814 Examiner. Blechinger, Todd P.                 Level:     Ill     Reviewer: Timm, Jeremy             Date: 5/25/2005 Examiner. Jensen, Arlen                       Level:     II   Site Review: Wren, Jerry             Date: 5/25/2005 Other. N/A                                 Level:     N/A   ANII Review: Daly, Gerald             Date: 6/2112005 Comments: W-14 Coverage plot Sketch or Photo: J:%lSlDataISl\Pl2_05 outage\Scans\2005U023 500814 coverage plot.jpg
Supplemental Report Report No.:
*,-      -S   l   n       r <e         Set --         .
2005U023 Page:
: -'.-.:.S..........                           /:
3 of 4
Summary No.: 500814 Examiner. Blechinger, Todd P.
Level:
Ill Reviewer: Timm, Jeremy Date: 5/25/2005 Examiner. Jensen, Arlen Level:
II Site Review: Wren, Jerry Date: 5/25/2005 Other. N/A Level:
N/A ANII Review: Daly, Gerald Date:
6/2112005 Comments: W-14 Coverage plot Sketch or Photo: J:%lSlDataISl\\Pl2_05 outage\\Scans\\2005U023 500814 coverage plot.jpg
- S l
n r <e Set
: -'.-.:.S..........:-: : :.:.::'..:.,...................................  
/:
Ad.inl.upeetaeot <edit6 f-o Setup
Ad.inl.upeetaeot <edit6 f-o Setup


NM76)                                                               Supplemental Report Report No.:     2005U023 Page:     4     of   4 Summary No.: 500814 Examiner: Blechinger, Todd P.                                   Level:   liI           Reviewer: Timm, Jeremy                                         Date:  5125/2005 Examiner: Jensen, Arlen                                        Level:  II        Site Review: Wren, Jerry                                         Date:   5/25/2005 Other: N/A                                                Level:  N/A        ANII Review: Daly, Gerald                                          Date:   6/21/2005 Comments: W-14 Limitation photo No downstream scan due to Flange configuration.
NM76)
Supplemental Report Report No.:
2005U023 Page:
4 of 4
Summary No.: 500814 Examiner: Blechinger, Todd P.
Examiner: Jensen, Arlen Other: N/A Level:
liI Level:
II Level:
N/A Reviewer: Timm, Jeremy Site Review: Wren, Jerry ANII Review: Daly, Gerald Date:
5125/2005 Date:
5/25/2005 Date:
6/21/2005 Comments: W-14 Limitation photo No downstream scan due to Flange configuration.
Upstream exam limited for 17" at 0&deg; & 15" at 180&deg; due to support interference.
Upstream exam limited for 17" at 0&deg; & 15" at 180&deg; due to support interference.
CW & CCW scans limited for 12" at 0&deg; due to support Interference.
CW & CCW scans limited for 12" at 0&deg; due to support Interference.
Sketch or Photo: J:\lSIData~ISI\PI2_05 outage\Photos\TODD05-17 TB\DSC01443.JPG                     J:\lSIData\ISl\PI2_05 outage\Photos\TODDN05-17 TB\DSC01444.JPG Additional - Supplemental Reports <edit from Setup>
Sketch or Photo: J:\\lSIData~ISI\\PI2_05 outage\\Photos\\TODD05-17 TB\\DSC01443.JPG J:\\lSIData\\ISl\\PI2_05 outage\\Photos\\TODDN05-17 TB\\DSC01444.JPG Additional - Supplemental Reports <edit from Setup>


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                 SECTION WORK INSTRUCTION t
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION I>PX t
I>PX a       -?NFO   AT1   - S-X
a  
                  . Procedure may be performed from memory.
-?NFO AT1  
                  . Userremains responsible forprocedure adherence.
- S-X Procedure may be performed from memory.
                  . Procedure should be available, but not necessarily at the work location.
Userremains responsible forprocedure adherence.
O.C. REVIEW DATE:       OWNER:   .                                          EFFECTIVE DATE NR                               T. Downing                           4/19105
Procedure should be available, but not necessarily at the work location.
O.C. REVIEW DATE:
OWNER:
EFFECTIVE DATE NR T. Downing 4/19105


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                         SECTION WORK INSTRUCTION NUMBER:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:
LIMITATIONtS       To NDESWI                       NDE-LTS-1
LIMITATIONtS To NDESWI NDE-LTS-1
                                      ,LIMITATIONS TO NDEREV:                                         I
,LIMITATIONS TO NDEREV:
________________                                            .;..Page                             2 of 13 1.0       PURPOSE This procedure provides instruction for identifying, quantifying and recording of limitations encountered while performing NDE examinations under the ISI program.
I
 
.;..Page 2 of 13 1.0 PURPOSE This procedure provides instruction for identifying, quantifying and recording of limitations encountered while performing NDE examinations under the ISI program.
==2.0      REFERENCES==


==2.0 REFERENCES==
This procedure complies with the applicable portions of the following referenced documents:
This procedure complies with the applicable portions of the following referenced documents:
2.1   Nuclear Regulatory Commission Regulatory Guide - 1.150 "Ultrasonic Testing of Reactor Vessel Welds during Preservice and Inservice Examinations", (Rev. 1 dated Feb. 1983).
2.1 Nuclear Regulatory Commission Regulatory Guide - 1.150 "Ultrasonic Testing of Reactor Vessel Welds during Preservice and Inservice Examinations", (Rev. 1 dated Feb. 1983).
2.2   Code case N-460 - Alternative Examination Coverage for Class 1 and Class 2 Welds - Section Xl, Division 1.
2.2 Code case N-460 - Alternative Examination Coverage for Class 1 and Class 2 Welds - Section Xl, Division 1.
2.3   Procedure SWI NDE-NDE-1, 'Equipment, Personnel and Material Reporting."
2.3 Procedure SWI NDE-NDE-1, 'Equipment, Personnel and Material Reporting."
2.4   5AWI 14.6.0 "ISI Examination Program" 3.0       APPLICABILITY 3.1   This procedure is applicable to examinations performed at Prairie Island Nuclear Generating Plant.
2.4 5AWI 14.6.0 "ISI Examination Program" 3.0 APPLICABILITY 3.1 This procedure is applicable to examinations performed at Prairie Island Nuclear Generating Plant.
3.2   This procedure is to be followed when it has been determined that there is a limitation which prevents obtaining full coverage of an area or volume as stated by the applicable examination procedure.
3.2 This procedure is to be followed when it has been determined that there is a limitation which prevents obtaining full coverage of an area or volume as stated by the applicable examination procedure.
For ultrasonic examinations, this would mean less than all of the required scans and/or a reduction of required scan path for one or more scans.
For ultrasonic examinations, this would mean less than all of the required scans and/or a reduction of required scan path for one or more scans.


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                           SECTION WORK INSTRUCTION NUMBER:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:
SWI NDE-LTS-1 LIMITATIONS TO NDE                                 REV:         1
SWI NDE-LTS-1 LIMITATIONS TO NDE REV:
______________ -iPage _                                                                            3 of 13 4.0       DEFINITIONS 4.1   Limitation - something that limits, restraint: An obstacle to the performance of an examination procedure.
1
4.2   Evaluation - to determine the significance, worth, or condition of, usually by careful appraisal and study.
-iPage 3 of 13 4.0 DEFINITIONS 4.1 Limitation - something that limits, restraint: An obstacle to the performance of an examination procedure.
4.3   Practical -" of, relating to, or manifested in practice or action: not theoretical or ideal; concerned with voluntary action and ethical decisions. Useful." For this application this is interpreted to mean, for a specific case the benefits of a proposed action outweigh the negative aspects of that action.
4.2 Evaluation - to determine the significance, worth, or condition of, usually by careful appraisal and study.
5.0       PREREQUISITES Personnel Requirements 5.1   Examination personnel certification and eye examinations SHALL be documented in accordance with SWI NDE-NDE-1.
4.3 Practical -" of, relating to, or manifested in practice or action: not theoretical or ideal; concerned with voluntary action and ethical decisions. Useful." For this application this is interpreted to mean, for a specific case the benefits of a proposed action outweigh the negative aspects of that action.
5.2   Nondestructive examination personnel SHALL be certified to a minimum of Level I in the appropriate method to operate equipment and Level II to interpret test results.
5.0 PREREQUISITES Personnel Requirements 5.1 Examination personnel certification and eye examinations SHALL be documented in accordance with SWI NDE-NDE-1.
6.0       EQUIPMENT This item is not applicable to this procedure. If alternate methods are required to augment coverage, that work SHALL be done under a separate procedure.
5.2 Nondestructive examination personnel SHALL be certified to a minimum of Level I in the appropriate method to operate equipment and Level II to interpret test results.
6.0 EQUIPMENT This item is not applicable to this procedure. If alternate methods are required to augment coverage, that work SHALL be done under a separate procedure.


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                           SECTION WORK INSTRUCTION PRAIRIE ISLAND GENERATING r          PLANT NUCLEAR                                        SECTION T      WORK INSTRUCTION NUMBER:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION r
T NUMBER:
SWI NDE-LTS-1 LIMITATIONS TO NDEREV:
SWI NDE-LTS-1 LIMITATIONS TO NDEREV:
___                                                                    Page 4 of 13 7.0     INSTRUCTIONS 7.1   Initial Examination Where the examiner is not able to complete a full examination as dictated by applicable procedure, the following steps SHALL be taken:
Page 4 of 13 7.0 INSTRUCTIONS 7.1 Initial Examination Where the examiner is not able to complete a full examination as dictated by applicable procedure, the following steps SHALL be taken:
7.1.1     Complete original examination on accessible portions.
7.1.1 Complete original examination on accessible portions.
7.1.2     Make sketch which includes dimensions defining location and size of limitations using a report format similar to that shown in Figure 3.
7.1.2 Make sketch which includes dimensions defining location and size of limitations using a report format similar to that shown in Figure 3.
7.1.3     Describe the limitation including what it is and how it interferes with the exam. State what appears to be required to remove the limitation using a report format similar to that shown in Figure 3.
7.1.3 Describe the limitation including what it is and how it interferes with the exam. State what appears to be required to remove the limitation using a report format similar to that shown in Figure 3.
7.1.4     For volumetric examinations, construct a surface profile using a surface contour gauge and perform a thickness profile (typically one reading each 1/2" in a line) of the area that encompasses the code required volume. For UT that would include the available scanning surface.
7.1.4 For volumetric examinations, construct a surface profile using a surface contour gauge and perform a thickness profile (typically one reading each 1/2" in a line) of the area that encompasses the code required volume. For UT that would include the available scanning surface.
7.1.5     Record radiation field information on the report (this may require assistance from the health physics group).
7.1.5 Record radiation field information on the report (this may require assistance from the health physics group).
7.1.6     Sign and date the data sheet then forward it to the NDE Level IlIl.
7.1.6 Sign and date the data sheet then forward it to the NDE Level IlIl.
7.2   Evaluation 7.2.1     The data gathered by the initial examiner SHALL be reviewed by the NDE Level Ill or/ designee to determine if alternate methods may be used to achieve additional coverage.
7.2 Evaluation 7.2.1 The data gathered by the initial examiner SHALL be reviewed by the NDE Level Ill or/ designee to determine if alternate methods may be used to achieve additional coverage.
7.2.2     If alternate methods would provide additional coverage, a review of the benefit versus the required resources (radiation dose, time, cost etc.) to achieve that coverage SHALL be performed by the NDE Level Ill to determine if that action is practical (see Step 7.3).
7.2.2 If alternate methods would provide additional coverage, a review of the benefit versus the required resources (radiation dose, time, cost etc.) to achieve that coverage SHALL be performed by the NDE Level Ill to determine if that action is practical (see Step 7.3).


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                                 SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:           I
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:
_ _ _ _  _ _ _ _ _ _ __      __  _  _ __'_      _  __  _  _P                               a g e 5 of 1 3 7.2.3     If it is determined that the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%.
I
_P a g e 5 o f 1 3 7.2.3 If it is determined that the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%.
The applicable examination records SHALL identify both the cause and percentage of reduced examination coverage (see Step 7.4).
The applicable examination records SHALL identify both the cause and percentage of reduced examination coverage (see Step 7.4).
7.3         Alternate Methods to Achieve Coverage 7.3.1     For surface examinations, MT and PT may be interchanged / intermixed as appropriate to the material and the conditions.
7.3 Alternate Methods to Achieve Coverage 7.3.1 For surface examinations, MT and PT may be interchanged / intermixed as appropriate to the material and the conditions.
7.3.2     For volumetric examinations, RT may be substituted for or augment UT assuming the ability to drain the line, and that the wall thickness / diameter is within a practical range.
7.3.2 For volumetric examinations, RT may be substituted for or augment UT assuming the ability to drain the line, and that the wall thickness / diameter is within a practical range.
7.3.3     For UT, use of other angles, full node or node and one half calibrations, skewed scans or approach from another surface to achieve additional coverage SHALL be considered.
7.3.3 For UT, use of other angles, full node or node and one half calibrations, skewed scans or approach from another surface to achieve additional coverage SHALL be considered.
7.4         Determining Coverage Achieved When evaluation of initial and alternate examination methods results in examinations, which do not provide full coverage, a determination of percent coverage SHALL be made. The required examination coverage is defined by applicable figures in ASME Sect Xl.
7.4 Determining Coverage Achieved When evaluation of initial and alternate examination methods results in examinations, which do not provide full coverage, a determination of percent coverage SHALL be made. The required examination coverage is defined by applicable figures in ASME Sect Xl.
7.4.1     For surface examinations, a worksheet similar to that shown in Figure 4 SHALL be completed.
7.4.1 For surface examinations, a worksheet similar to that shown in Figure 4 SHALL be completed.
i   For ASME Section Xl appendix Vill exams, code coverage
i For ASME Section Xl appendix Vill exams, code coverage
                .                    ,maybe limited by what the procedure has been demonstrated.
,may be limited by what the procedure has been demonstrated.
7.4.2     For volumetric examinations, a worksheet similar to that shown in Figure 5 or Figure 6 (ultrasonic examinations) SHALL be completed.
7.4.2 For volumetric examinations, a worksheet similar to that shown in Figure 5 or Figure 6 (ultrasonic examinations) SHALL be completed.


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                       SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:       1 Page 6 of 13 7.5   Should the evaluation show that 90% weld coverage has been achieved, attach all related information to the original NDE report and no further action is required.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:
7.6   Contractor procedures for performing examinations utilizing automated equipment (e.g. reactor vessel and nozzle safe-end exams) SHALL be reviewed by an NDE Level IlIl in the appropriate method to ensure the requirements for identifying, quantifying and recording of limitations encountered are adequately addressed.
1 Page 6 of 13 7.5 Should the evaluation show that 90% weld coverage has been achieved, attach all related information to the original NDE report and no further action is required.
7.7   When it has been determined that the maximum examination coverage practically achievable for a code required item is less than required; a relief request is required to be submitted to the NRC (5AWI 14.6.0).
7.6 Contractor procedures for performing examinations utilizing automated equipment (e.g. reactor vessel and nozzle safe-end exams) SHALL be reviewed by an NDE Level IlIl in the appropriate method to ensure the requirements for identifying, quantifying and recording of limitations encountered are adequately addressed.
8.0     ACCEPTANCE CRITERIA This item is not applicable to this procedure.
7.7 When it has been determined that the maximum examination coverage practically achievable for a code required item is less than required; a relief request is required to be submitted to the NRC (5AWI 14.6.0).
9.0     REPORTING 9.1   Information addressed in Figures 3, 4, 5 and 6 (as applicable) SHALL be reported.
8.0 ACCEPTANCE CRITERIA This item is not applicable to this procedure.
9.2   Information for examinations that are required to meet Reg. Guide 1.150 SHALL also include the following from Appendix A - Alternate Method:
9.0 REPORTING 9.1 Information addressed in Figures 3, 4, 5 and 6 (as applicable) SHALL be reported.
7.c 'The best estimate of the portion of the volume required to be examined by the ASME Code that has not been effectively examined such as volumes of material near each surface because of near-field or other effects, volumes near interfaces between cladding and parent metal, volumes shadowed by laminar material defects, volumes shadowed by part geometry, volumes inaccessible to the transducer, volumes affected by electronic gating, and volumes near the surface opposite the transducer. Sketches and/or descriptions of the tools, fixtures and component geometry which contribute to incomplete coverage should be included."
9.2 Information for examinations that are required to meet Reg. Guide 1.150 SHALL also include the following from Appendix A - Alternate Method:
9.3     Reference System Recording of limitations SHALL be based on the reference system shown in the original examination procedure.
7.c  
'The best estimate of the portion of the volume required to be examined by the ASME Code that has not been effectively examined such as volumes of material near each surface because of near-field or other effects, volumes near interfaces between cladding and parent metal, volumes shadowed by laminar material defects, volumes shadowed by part geometry, volumes inaccessible to the transducer, volumes affected by electronic gating, and volumes near the surface opposite the transducer. Sketches and/or descriptions of the tools, fixtures and component geometry which contribute to incomplete coverage should be included."
9.3 Reference System Recording of limitations SHALL be based on the reference system shown in the original examination procedure.


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                       SECTION WORK INSTRUCTION 9.4   Documentation A picture of the limitation should be taken and added to the description, preferably in a digital format.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION 9.4 Documentation A picture of the limitation should be taken and added to the description, preferably in a digital format.
10.0     RECORDS 10.1     Inservice inspection examinations SHALL be incorporated in the ISI records. See UISI Examination Program."
10.0 RECORDS 10.1 Inservice inspection examinations SHALL be incorporated in the ISI records. See UISI Examination Program."
10.2     Records of other examinations SHALL be the responsibility of the organization requesting the examination.
10.2 Records of other examinations SHALL be the responsibility of the organization requesting the examination.
11.0     ATTACHMENTS 11.1     Figure 1 - Example of UT Scan Coverage 11.2     Figure 2- Example of UT, One Sided Exam, Supplemental Coverage 11.3     Figure 3 - Limitation Data Sheet 11.4     Figure 4 - Determination of Percent Coverage for Surface Examinations 11.5     Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe 11.6     Figure 6   - Determination of Percent Coverage for UT Examinations -Vessels 12.0    
11.0 ATTACHMENTS 11.1 Figure 1 - Example of UT Scan Coverage 11.2 Figure 2-Example of UT, One Sided Exam, Supplemental Coverage 11.3 Figure 3 - Limitation Data Sheet 11.4 Figure 4 - Determination of Percent Coverage for Surface Examinations 11.5 Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe 11.6 Figure 6 -
Determination of Percent Coverage for UT Examinations -Vessels 12.0  


==SUMMARY==
==SUMMARY==
OF SIGNIFICANT CHANGES 2.1       Deleted ASME Code year, covered with 5AWI 14.6.0.
OF SIGNIFICANT CHANGES 2.1 Deleted ASME Code year, covered with 5AWI 14.6.0.
5.1       Changed SWI NDE-0 to SWI NDE-NDE-1.
5.1 Changed SWI NDE-0 to SWI NDE-NDE-1.


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                             SECTION WORK INSTRUCTION Figure 1 - Example of UT scan coverage I--,
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 1 - Example of UT scan coverage I--
C"'
C"',
b.-
b.-
a>             a)a
a>
                        <D CD E
<D E
E
E CD
:9
:9 a)a


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                             SECTION WORK INSTRUCTION Figure 2 - Example of UT, One Sided Exam, Supplemental Coverage 0
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 2 - Example of UT, One Sided Exam, Supplemental Coverage 0
0 z.)_-
0  
0)2
.)
                          -to a) 9C)
z _-
                          .-0
0)2 a)
                              >)o- .4.-
C)
-to 9
& o-
>)
.-0  
.4.-
a.
a.
0E
0 E


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                         SECTION WORK INSTRUCTION
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION stt.-  
                        >    stt.-       ,8   i. i-     s,   .>>      t A ^NUMBER:
,8
SWI NDE-LTS-1 LIMITATIONS TO NDEREV:                                       I Page 10 of 13 Figure 3 -Limitation Data Sheet TITLE: Limitations to NDE NUMBER:       SWI NDE-LTS-1     Revision 0 Figure 3 Limitation Data Sheet Initial exam report #                         Procedure #
: i.
ISO #                                        Item #
i-s, t
Description of Limitation Sketch of Limitation Limitation removal requirements Radiation field ExaminerD                                                 Date:
A  
^NUMBER:
SWI NDE-LTS-1 LIMITATIONS TO NDEREV:
I Page 10 of 13 Figure 3 -Limitation Data Sheet TITLE:
Limitations to NDE NUMBER:
SWI NDE-LTS-1 Revision 0 Figure 3 Limitation Data Sheet Initial exam report #
ISO #
Procedure #
Item #
Description of Limitation Sketch of Limitation Limitation removal requirements Radiation field ExaminerD Date:


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                                       SECTION WORK INSTRUCTION Figure 4 -Determination of Percent Coverage for Surface Examinations TITLE: Limitations to NDE NUMBER:             SWI NDE-LTS-1           Revision 0 Figure 4 Determination of Percent Coverage for Surface Examinations This is a sample form only Initial exam rpt     #                                     Procedure #
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 4 -Determination of Percent Coverage for Surface Examinations TITLE:
ISO #                                                       Item#_                    _
Limitations to NDE NUMBER:
Applicable Code figure       #
SWI NDE-LTS-1 Revision 0 Figure 4 Determination of Percent Coverage for Surface Examinations This is a sample form only Initial exam rpt #
Procedure #
ISO #
Item#_
Applicable Code figure #
Area Required (as shown in applicable code reference drawing)
Area Required (as shown in applicable code reference drawing)
Length     _        _
Length
* Width
* Width
          = Total area required                             square inches Coverage Achieved Area examined                             sq. in. /Total area required (100%)                 sq. in.
= Total area required square inches Coverage Achieved Area examined sq. in. /Total area required (100%)
          = Percent coverage                           % (area required - area of limitations = area examined)
sq. in.
= Percent coverage  
% (area required - area of limitations = area examined)
To determine length of a circumferential weld Note - Diameter refers to actual external diameter not pipe size (see table below)
To determine length of a circumferential weld Note - Diameter refers to actual external diameter not pipe size (see table below)
Diameter                     *(Pi) 3.1416
Diameter  
          = Length                     inches Pipe       Actual             (Length)                     Pipe   Actual       (Length)
*(Pi) 3.1416
Size       Diameter         Circumference                   Size   Diameter   Circumference 2         2.375               7.46                       12     12.75         40.06 2.5         2.875               9.03                       14       14.0         43.98 3           3.5               11.0                       16       16.0         50.27 3.5           4.0               12.57                       18       18.0         56.55 4           4.5               14.14                       20     20.0           62.83 5         5.563               17.48                       22     22.0           69.12 6         6.625               20.81                       24     24.0           75.40 8         8.625               27.10                       30     30.0           94.25 10         10.75               33.77         _                                              I NDE     Level IlIl:                                                     Date:
= Length inches Pipe Actual (Length)
Pipe Actual (Length)
Size Diameter Circumference Size Diameter Circumference 2
2.375 7.46 12 12.75 40.06 2.5 2.875 9.03 14 14.0 43.98 3
3.5 11.0 16 16.0 50.27 3.5 4.0 12.57 18 18.0 56.55 4
4.5 14.14 20 20.0 62.83 5
5.563 17.48 22 22.0 69.12 6
6.625 20.81 24 24.0 75.40 8
8.625 27.10 30 30.0 94.25 10 10.75 33.77 I
NDE Level IlIl:
Date:


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                             SECTION WORK INSTRUCTION NUMBER:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:
SWI NDE-LTS-1 LIMITATIONS TO NDE                                     REV:
SWI NDE-LTS-1 LIMITATIONS TO NDE REV:
v                                                                                           Page 12 of 13 Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe TITLE: Limitations to NDE NUMBER:         SWI NDE-LTS-1       Revision 0 Figure 5 Determination of Percent Coveraqe for UT Examinations - Pipe This Is a sample form onlv Initial exam rpt #                               Procedure #
v Page 12 of 13 Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe TITLE:
ISO #                                           Item #
Limitations to NDE NUMBER:
SWI NDE-LTS-1 Revision 0 Figure 5 Determination of Percent Coveraqe for UT Examinations - Pipe This Is a sample form onlv Initial exam rpt #
Procedure #
ISO #
Item #
Applicable Code figure #
Applicable Code figure #
45 deg Scan 1           % length X     _  % volume of length /100 =       % total for Scan 1 Scan 2           % length X     _ % volume of length /100 =         % total for Scan 2 Scan 3           % length X         % volume of length /100 =       % total for Scan 3 Scan 4           % length X         % volume of length / 100 = _ % total for Scan 4 Add totals and divide by # scans =                 %total for 45 deg Other deg - ..        (to be used for supplemental scans)
45 deg Scan 1  
% length X  
% volume of length /100 =  
% total for Scan 1 Scan 2  
% length X  
% volume of length /100 =  
% total for Scan 2 Scan 3  
% length X  
% volume of length /100 =  
% total for Scan 3 Scan 4  
% length X  
% volume of length / 100 =
_ % total for Scan 4 Add totals and divide by # scans =  
% total for 45 deg Other deg -
(to be used for supplemental scans)
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
The data to be listed below is for coverage that was not obtained with the 45 deg scans.
Scan I           % length X         % volume of length / 100 =     % total for Scan 1 Scan 2           % length X         % volume of length / 100 =     % total for Scan 2 Scan 3           % length X         % volume of length / 100       % total for Scan 3 Scan 4           % length X         % volume of length /1 00 =     % total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine;
Scan I  
                        % total for complete exam Example -45 deg scan 1 = 63% plus supplemental 60 deg scan I = 28% (of remaining required scan volume) for total of 91% coverage for scan 1 volume. Repeat for the remaining scans, add together and divide by the # of scans (typically 4).
% length X  
NDE Level III:                                                 Date:
% volume of length / 100 =  
% total for Scan 1 Scan 2  
% length X  
% volume of length / 100 =  
% total for Scan 2 Scan 3  
% length X  
% volume of length / 100  
% total for Scan 3 Scan 4  
% length X  
% volume of length /1 00 =  
% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine;
% total for complete exam Example -45 deg scan 1 = 63% plus supplemental 60 deg scan I = 28% (of remaining required scan volume) for total of 91% coverage for scan 1 volume. Repeat for the remaining scans, add together and divide by the # of scans (typically 4).
NDE Level III:
Date:
NDE Level Ill:
Date:
Date:
NDE    Ill:
Level


PRAIRIE ISLAND NUCLEAR GENERATING PLANT                                             SECTION WORK INSTRUCTION Figure 6 - Determination of Percent Coverage for UT Examinations -Vessels TiTLE: Limitations to NDE NUMBER:         SWI NDE-LTS-1     Revision 0 Figure 6 Determination of Percent Coverage for UT Examinations - Vessels This is a sample form only Initial exam rpt #                             Procedure   #
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 6 - Determination of Percent Coverage for UT Examinations -Vessels TiTLE:
ISO #                                           Item   _
Limitations to NDE NUMBER:
Applicable Code figure #
SWI NDE-LTS-1 Revision 0 Figure 6 Determination of Percent Coverage for UT Examinations - Vessels This is a sample form only Initial exam rpt #
0 deq Planar Scan             % length X       % volume of length / 100   -       % total for 0 deg 45 deg Scan 1           % length X       % volume of length /100 =           % total for Scan 1 Scan 2           % length X       % volume of length /100 =           % total for Scan 2 Scan 3           % length X       % volume of length / 100   =     _  % total for Scan 3 Scan 4           % length X       % volume of length / 100   =     _  % total for Scan 4 Add totals and divide by # scans =         % total for 45 deg 60 deg Scan I           % length X       % volume of length / 100 =         % total for Scan I Scan 2           % length X       % volume of length / 100   =     _  % total for Scan 2 Scan 3           % length X       % volume of length / 100 =         % total for Scan 3 Scan 4           % length X   _    % volume of length /100   =     _  % total for Scan 4 Add totals and divide by # scans =         % total for 60 deg Percent complete coverage Add totals for each angle and scan required and divide by # angles to determine;
Procedure #
% total for complete exam Note: Supplemental coverage may be achieved by use of other angles / methods. When used, the coverage for volume not obtained with angles as noted above shall be calculated and added to the total to provide the percent total for the complete examination.
ISO #
NDE Level III:                                                 Date:
Item Applicable Code figure #
NDELevelIll:                                                         -}}
0 deq Planar Scan  
% length X  
% volume of length / 100 -
% total for 0 deg 45 deg Scan 1  
% length X  
% volume of length /100 =  
% total for Scan 1 Scan 2  
% length X  
% volume of length /100 =  
% total for Scan 2 Scan 3  
% length X  
% volume of length / 100 =  
% total for Scan 3 Scan 4  
% length X  
% volume of length / 100 =  
% total for Scan 4 Add totals and divide by # scans =  
% total for 45 deg 60 deg Scan I  
% length X  
% volume of length / 100 =  
% total for Scan I Scan 2  
% length X  
% volume of length / 100 =  
% total for Scan 2 Scan 3  
% length X  
% volume of length / 100 =  
% total for Scan 3 Scan 4  
% length X  
% volume of length /100 =  
% total for Scan 4 Add totals and divide by # scans =  
% total for 60 deg Percent complete coverage Add totals for each angle and scan required and divide by # angles to determine;
% total for complete exam Note: Supplemental coverage may be achieved by use of other angles / methods. When used, the coverage for volume not obtained with angles as noted above shall be calculated and added to the total to provide the percent total for the complete examination.
NDE Level III:
Date:
NDE Level Ill:
Date:
-}}

Latest revision as of 15:30, 15 January 2025

Request for Relief No. 21, for the Plant 3rd 10-Year Interval Inservice Inspection Program
ML052560277
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 09/08/2005
From: Thomas J. Palmisano
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-PI-05-082
Download: ML052560277 (83)


Text

Committed to NucearExellen Nuclear Management Company, LLC Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East

  • Welch MN 55089 SEP 0 8 2005 L-PI-05-082 10 CFR 50.55a U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant Unit 2 Docket No. 50-306 License No. DPR-60 Request for Relief No. 21, for the Unit 2 3rd 10-year Interval Inservice Inspection Program On November 15,1994 we submitted for review our third 10-year Inservice Inspection Examination Plan for Unit 2 and, on April 19,1995, relief request revisions associated with that plan. The NRC issued its evaluation of the 3rd 10-year Interval Program Plan on February 22, 1996.

The purpose of this letter is to submit a relief request for 'limited examinations" associated with that plan. Attached is Unit 2 Relief Request No. 21, Revision 0 which addresses those limited examinations. We are requesting relief pursuant to 10 CFR Part 50, Section 50.55a(g)(5)(iv) due to the impracticality of obtaining "100%"

examination coverage for the affected items.

Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.

Thomas J. Palmisano Site Vice President, Prairie Island Nuclear Generating Plant cc: (see next page) 2047 1717 Wakonade Drive East

  • Welch, Minnesota 55089-9642 Telephone: 651.388.1121

Document Control Desk Page 2 cc:

Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure

omtNu Committed to Nu~erxcle Nuclear Management Company, LLC Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East

  • Welch MN 55089 L-PI-05-082 10 CFR 50.55a U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant Unit 2 Docket No. 50-306 License No. DPR-60 Request for Relief No. 21, for the Unit 2 3rd 10-year Interval Inservice Inspection Program On November 15, 1994 we submitted for review our third 10-year Inservice Inspection Examination Plan for Unit 2 and, on April 19, 1995, relief request revisions associated with that plan. The NRC issued its evaluation of the 3rd 10-year Interval Program Plan on February 22, 1996.

The purpose of this letter is to submit a relief request for "limited examinations" associated with that plan. Attached is Unit 2 Relief Request No. 21, Revision 0 which addresses those limited examinations. We are requesting relief pursuant to 10 CFR Part 50, Section 50.55a(g)(5)(iv) due to the impracticality of obtaining "100%"

examination coverage for the affected items.

Summarv of Commitments This letter contains no new commitments and no revisions to existing commitments.

Thomas J. Palmisano Site Vice President, Prairie Island Nuclear Generating Piant cc: (see next page) 1717 Wakonade Drive East

  • Welch, Minnesota 55089-9642 Telephone: 651.388.1121

Document Control Desk Page 2 cc:

Regional Administrator, USNRC, Region Ill Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Chief Boiler Inspector, State of Minnesota Enclosure

ENCLOSURE September 2005 ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval This enclosure consists of a 7 page write-up, entitled, 'ISI Relief Request No. 21 (Rev.

0), Prairie Island Unit 2, 3rd Interval" and the following attachments:

  • Attachment 1, Drawing No. 2-ISI-40, 1 page
  • Attachment 2, Inspection Report No. 2005VE019, 8 pages
  • Attachment 3, Inspection Report No. 2005VE021, 10 pages
  • Attachment 4, Inspection Report No. 2005VE023, 12 pages
  • Attachment 5, Inspection Report No. 2005VE024, 10 pages
  • Attachment 6, Drawing No. 2-ISI-33A, 1 page
  • Attachment 7, Inspection Report No. 2005U036, 5 pages
  • Attachment 8, Drawing No. 2-ISI-1OA, 1 page
  • Attachment 9, Inspection Report No. 2005U024, 5 pages
  • Attachment 10, Drawing No. 2-ISI-47B, I page
  • Attachment 11, Inspection Report No. 2005U023, 4 pages
  • Attachment 12, Prairie Island Procedure SWI NDE-LTS-1, Rev. 1 'Limitations to NDE" 13 pages 78 pages follow

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Limited Examination SYSTEM:

Various CLASS: 1 and 2 CATEGORY: Various ITEM NO: Various Impractical Examination Requirements:

American Society of Mechanical Engineers (ASME) Section Xl (1989 Edition, no addenda)

Code requires full examination coverage of inservice inspection (ISI) components per Table IWB-2500-1, and IWC-2500-1. NRC Regulatory Guide 1.147 endorses the use of Section Xl Code Case N-460, "Alternative Examination Coverage for Class 1 and Class 2 Welds." This code case allows greater than 90% coverage of a weld to meet the "essentially 100%"

requirement.

In addition, NRC Information Notice 98-42 "Implementation of 10 CFR 50.55a(g) Inservice Inspection requirements" dated Dec. 1, 1998, states, "The NRC has adopted and further refined the definition of 'essentially 100 percent' to mean 'greater than 90 percent' in 10 CFR 50.55a(g)(6)(ii)(A)(2) for required examination coverage of reactor pressure vessel welds.

This standard has been applied to all examination of welds or other areas required by ASME Section Xl."

The Prairie Island construction permit was issued in 1967. This facility was designed and constructed with limited accessibility due to component configurations and/or physical barriers for which 100% examination coverage is not achievable on some ISI components examined for the Third Ten Year Interval.

Basis for Relief:

This request is submitted pursuant to 10 CFR 50.55a(g)(5)(iv) which states, 'Where an examination requirement by the code or addenda is determined to be impractical by the licensee and is not included in the revised inservice inspection program as permitted by paragraph (g)(4) of this section, the basis for this determination must be demonstrated to the satisfaction of the Commission."

The regulation further states in 10 CFR 50.55a(g)(1) that, "For a boiling or pressurized water-cooled nuclear power facility whose construction permit was issued before January 1, 1971, components (including supports) must meet the requirements of paragraphs (g) (4) and (g)(5) of this section to the extent practical." 10 CFR 50.55a(g)(4) states, "Throughout the service life of a boiling or pressurized water-cooled nuclear power facility, components (including supports) which are classified as ASME Code Class 1, Class 2, and Class 3 must meet the requirements, except design and access provisions and preservice examination requirements, set forth in Section Xl of editions of the ASME Boiler and Pressure Vessel Code... to the extent practical within the limitations of design, geometry and materials of construction of the components."

1 of 7

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Prairie Island was designed and constructed prior to development of ASME Xl, therefore design for accessibility and inspection coverage is not in many cases, sufficient to permit satisfying the current Code requirements. Limitations to inspections are primarily due to design obstructions, component configurations and interference. In the case of circumferential welds a limitation from ultrasonic examination may exist simply because of weld joint configuration as with a pipe to valve or fitting weld.

A summary of the limited examinations are described below and also included in Table 1, "Limited Examinations - Prairie Island Unit 2 - 2005 Refueling Outage."

Part A: Category B-D, "Full Penetration Welds of Nozzles in Vessels" Reactor Vessel (RV) Nozzle (N-7), Outlet Nozzle to Vessel Loon A:

The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.

The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vill, Supplements 4,6 and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.

The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.

The following supporting documentation has been provided:, ISI Drawing 2-ISI-40, Examination Report Number 2005VE019 and WesDyne report Reactor Vessel (RV) Nozzle (N-10), Outlet Nozzle to Vessel Loop B:

The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.

The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix Vil, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.

The examination was limited in both the parallel and perpendicular scans from the vessel ID to 78.56% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to do outside access and weld configuration.

The following supporting documentation has been provided:, ISI Drawing 2-ISI-40, Examination Report Number 2005VE021 and WesDyne report 2 of 7

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Reactor Vessel (RV) Nozzle (N-8), SI Nozzle to Vessel Loop A:

The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.

The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.

The examination was limited in both the parallel and perpendicular scans from the vessel ID to 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.

The following supporting documentation has been provided:, [SI Drawing 2-lSI-40, Examination Report Number 2005VE023 and WesDyne report Reactor Vessel (RV) Nozzle (N-I1), SI Nozzle to Vessel Loop B:

The Reactor Vessel Nozzle-to-Vessel weld is subject to a volumetric examination.

The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix ViII, Supplements 4, 6, and 7. The examination was conducted using 45-degree transducers. The nozzle and vessel material are SA 508.

The examination was limited in both the parallel and perpendicular scans from the vessel ID to 59.26% due to the proximity of the outlet nozzle protrusion to the nozzle to shell weld. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to no outside access and weld configuration.

The following supporting documentation has been provided: ISI Drawing ISI-40, Examination Report Number 2005VE024 and WesDyne report Part B: Category B-F, "Pressure Retaining Dissimilar Metal Welds" Reactor Coolant (RC) Weld (W-5), Nozzle to Safe End:

This dissimilar metal weld joint configuration is not currently covered by the demonstrated samples at the Electric Power Research Institute (EPRI) Perf6rmance Demonstration Initiative (PDI) center. Due to the design of the joint, no mockup could be created to examine this ultrasonically to meet Appendix VIII, Supplement 10.

3 of 7

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Therefore a supplemental ultrasonic (UT) exam was performed with the following results:

The Elbow to Safe End weld is subject to a volumetric examination and surface examination. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix ill. The examination was conducted using 45-degree refracted longitudinal transducers. The elbow and safe end material are SA 351-CF8 cast austenitic stainless and 308L stainless (this joint contains no Alloy 82/182 or 600). The examination was limited to 78.46% due to the OD profile of the cast stainless steel elbow. The UT examination is further hindered from the elbow side of the weld for obtaining meaningful ultrasonic data because of the elbow material being cast austenitic stainless steel. UT sound beam attenuation and propagation properties in cast stainless steel are extremely difficult. The ASME Code Committee and the industry Performance Demonstration Initiative (PDI) recognized that such examinations are difficult. ASME Section Xl, Appendix VIII, Supplement 9 has been in "course of preparation" for several years, hence, there are no qualified examination procedures or personnel to conduct the required examinations. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, the reactor vessel level would be required to be at reduced inventory below the center line of the hot leg, weld configuration, and the undue hardship imposed without offering any commensurate increase in safety with cost benefit.

The required surface examination was performed using liquid penetrant and was not limited. 100% of the required surface area was inspected (Inspection Report No.

2005P032). No relevant indications were detected.

The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 619/2005). No leakage was identified in the vicinity of the weld.

The following supporting documentation has been provided:, ISI Drawing 2-lSI-33A, Examination Report Number 2005U036 Part C: Category B-J, "Pressure Retaining Welds in Piping" Residual Heat Removal (RH) Weld (W-11) Valve to Pipe:

This piping weld is subject to be examined by both volumetric and surface examination methods. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VIII, Supplement 2. The examination was conducted using 45 and 60-degree transducers. The valve and piping material are austenitic stainless steel. The examination is limited to 50% in both the axial and circumferential directions from the piping side of the weld due to the weld joint configuration connection to the valve. The credited volumetric examination of the Weld 4 of 7

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Required Volume (WRV) was limited to 47.77% and only a single-sided examination could be performed. It should be noted that the volumetric examination was performed through 100% of the Code WRV; however, the PDI Appendix Vill procedure used is not qualified for the detection of flaws on the far side of single sided access examinations on austenitic stainless steel piping welds. The techniques employed for the examination provide for a best effort examination. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.

The required surface examination was performed using liquid penetrant and was not limited. 100% of the required surface area was inspected (Inspection Report No.

2005P019). No relevant indications were detected.

The weld is included in the boundary examined by VT-2 during pressure testing (SP 2070, Reactor Coolant System Integrity Test, completed on 6/9/2005). No leakage was identified in the vicinity of the weld.

The following supporting documentation has been provided:, ISI Drawing 2-ISI-1 OA, Examination Report Numbers 2005U024 Part D: Category C-F-2 "Pressure Retaining Welds in Carbon or Low Alloy Steel Piping" Main Steam (MS) Weld (W-14), Tee to Flange:

This tee to flange pipe weld is subject to be examined by both volumetric and surface examination methods. The reducer tee and pipe materials are carbon steel. The volumetric examination was performed using personnel and procedures qualified in accordance with Appendix VilI, Supplement 3. The examination was conducted using 45 and 60-degree transducers. The piping materials are A155 KC70. The credited volumetric examination of the WRV was limited to 74.85%. As an alternative to the ultrasonic examination, radiography was considered and determined to be an unacceptable substitute due to radiological constraints, weld configuration, and the undo hardship imposed without offering any commensurate increase in safety with cost benefit.

The required surface examination was performed using Dye Penetrant and 95.8% of the required surface area was inspected (Inspection Report No. 2005P043). No relevant indications were detected.

5 of 7

ISI Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval The weld is included in the boundary examined by VT-2 during pressure testing (SP 2168.1 1, completed 9/13/2003). No leakage was identified in the vicinity of the weld.

The following supporting documentation has been provided: 0, ISI Drawing 2-lSI-47B 1, Examination Report Number 2005U023 Additional Means of Establishing Component Integrity:

System integrity is monitored during normal operation by many direct and indirect methods, e.g., containment radiation monitoring, containment air monitoring, containment sump monitoring, containment temperature monitoring, system walk downs, surveillance testing, etc.

Alternate Examination:

The limitations have been noted on the ISI examination reports and are included in the 2005 ISI Outage Summary Report. NMC will continue to document limitations.

All in-service inspections at Prairie Island Unit 2 have been completed to the greatest extent practical. When limitations to required inspections are encountered, Prairie Island's "Limitations to NDE" procedure SWI NDE-LTS-1 was applied. SWI NDE-LTS-1 (Attachment

12) is used when an ASME Section XI Code required examination results in less than 90%

coverage. It requires a review of the procedures to obtain maximum coverage and documentation of the limitation. The procedure also examines whether an alternative method could be used to obtain better coverage as allowed by the Code. This procedure was used for all the items identified above and the maximum inspection coverage was achieved.

Limitations are due to design, geometry, and materials of construction of the components.

NMC will continue to utilize the most current techniques available for future examinations.

6 of 7

IS[ Relief Request No. 21 (Rev. 0), Prairie Island Unit 2, 3rd Interval Table 1. Limited Examinations - Prairie Island Unit 2 - 2005 Refueling Outage CSYSTEM Comp

,Method Io verage Rep ritatlonrt#-':

Cate~orpltem'N~.p;;.

ummary,#j~.sr~inj~~~-~~t¶iait~~

B-D 83.90 Reactor Vessel 2-ISI-40 N-7 Outlet Nozzle UT 78.56%

2005VE019 Limited due to 505018 to Vessel Weld configuration.

Loop A B-D B3.90 Reactor Vessel 2-ISI-40 N-10 Outlet Nozzle UT 78.56%

2005VE021 Limited due to 505020 to Vessel Weld configuration.

Loop B B-D B3.90 Reactor Vessel 2-ISI-40 N-8 Si Nozzle to UT 59.26%

2005VE023 Limited due to 505727 Vessel Weld configuration.

Loop A B-D B3.90 Reactor Vessel 2-ISI-40 N-11 SI Nozzle to UT 59.26%

2005VE024 Limited due to 505726 Vessel Weld configuration.

_ Loop B B-F B5.70 Reactor Coolant 2-ISI-33A W-5 50 degree UT

  • 0%

2005U036

  • No Demonstrated 501137 Elbow to 58.84%

technique at PDI for PI Nozzle configuration B-J B9.11 Residual Heat 2-lSI-10A W11 Valve to Pipe UT 44.77%

2005U024 Single side access Removal 501953 C-F-2 C5.80 Main Steam 2-lSI-47B W-14 Tee to Flange UT 74.85%

2005U023 Flange configuration and 500818 support adjacent to weld 7 of 7

,.;i 0

CONT. ON 2-ISI-33C T 2700 = Z no C

/- CONI. ON 4-%I-38_

X1

= WELD NO.

N

/

I CONT. ON 2-ISI-32C REACTOR VESSEL NOZZLES REF:

IFILE NO:21040R05 NS5i

( M&SP ) - P 1 -2 1 2 I DWN: DMN CHKD:

Q, APPD:

SYSTEM:REACTOR VESSEL NOZZLES LINE: NA DWG:

2-ISI-40 REV: 06 0

NM7ij' Ultrasonic Examination Site/Unit:

Summary No.:

Workscope:

PINGP /

P12 505018 Procedure:

Procedure Rev.:

Work Order No.:

UT-Vendor 0

0406670 Outage No.:

E031 Report No.:

2005VE019 Page:

1 of 5

'SI Code:

1989 Edition Cat./Iltem:

B-D/B3.90 Location:

Drawing No.:

2-ISI-40

==

Description:==

Outlet Nozzle to Vessel Weld Loop A System ID:

RV Component ID: N-7 Size/Length:

NA Thickness/Diameter:

9.17"153" Limitations:

See WesDyne exam report Comments:

See supplements and Refer to the applicable WesDyne report found in the book:

Prairie Island Nuclear Power Plant I Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005

^ 78.56%, See WesDyne final report Results:

NAD E IND i GEO E]

Indications allowable by Code Percent Of Coverage Obtained > 90%:

No Reviewed Previous Data:

Yes Examiner Level li Signature Date Reviewer Ig Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas Examiner Level N/A Signature Date Site Review Signature},.

r Date N/A Wren, Jerry P 5,i Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald tek)6*E

NM ')

Supplemental Report Report No.:

2005VE019 Page:

2 of 5

Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner:

NIA Other:

NIA Level:

II Reviewer Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald CPZJ1-Date:

Date:

5 '.vij Date: ISALrr,cS Comments:

Sketch or Photo: J:MlSIData]SIPI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\Flaw Sizing 1.bmp Summary No.:

.50C S-Of

/ 9 WorkScope:

_.z S -7 ISI Flaw Sizing Worksheet

1) Flaw Number
2) Itemt Number 8

3a, 90 Flaw Vtow Procedure:

tLX'rST-

z-;/-

A/z ProCcdura Rev.:

0 Work Order No.:

! 5 70

3) ISI Interval g_ _
4) Code Edition & Addenda j 9ff

/.

5) Method

-r-C) Flaw Sketch (See Selow)

Outage No.:

J° rZ, F,2c Report No.:

-76DS1VE O 19 Page:

of k* OK Reviewer W OK Reviewer

  • t 01< Reviewer k)

OK Revlc.er

  • Ja q

=,

SC/>

I

/1.-n I

//

17..

V

7) Calculations OK Reviewer Show determination of Surface onC i

S Show determination of oI D

to use

8)

Hit FE Pnrngraph---

ta

.. t-Was used M Yes PreparerC

9) Code Frtaw Dimensions 4g OK Reviewer

. IS o,

t nomnr--

9. :.

'I nmeasured"

10) Flow Typn 9

OK Reviewer S

b I 1) Flaw Characterization Figure tt OK Reviewer

2Z..--' A 5

3-2.4

12) Flaw Characterization Figure Number z

/

13) Was IWA-3300 Flaw Characterization followed?

0D Yes 0

No If no. why?

=.

5--

Reviewer 5

j/S

14) The correct Code Edition and Addenda was available and usexd.

g)

Yes Prepoaer-.

erLi.

J C9 OK Reviewer 52~

/~

___I 1 5) n d

d

16) Rl b

nd,

-2o-'

The results are correct and the methodology used Is in accordance The rev assures that the results are correct and the with applicable codes, standards. specilications and procedures.

methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

AdditlOnAl - tSI fr uSize Odt rfon, Set-up-Additional - Supplemental Reports <edit from Setup>

NM)

Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner:

N/A Other: NIA Supplemental Report Report No.:

2005VE019 Page:

3 of 5

Level:

II Reviewer, Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald C_

Date: _ _ _ _ _ _ _

Date:

-'--s ion Date:

t'A t6&

U)

Comments:

Sketch or Photo: J;\\lSIDataJSIxp12_05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\Flaw Disposition 1.bmp ilntUnit:

,P?

I Summary No.:

35 0

O 1,

Worhscope:

ISI Flaw Disposition Worksheet Procedure:

Ptr.s--

Z5"/-A/Z Procedure Rev.:

C>

Work Order No.:

O L/ 0 (,a CD 7

°

1 interval ode EdItlon & Addenda

/98 9

.'/o C, 4.P.

.Ceptanlce Standard B

- 5 S/

A, Outage No.:

Pr2 ig Report No.:

cS

-J, c

9 Page:

of ED OK Reviewer C;4 1 zJ 4OK Reviewer

$a-i 6b OK Reviewer

(!

OK Reviewer P f'

1) Flew Number
2) Itemn Number B. 3

. q eD

3) IS
4) C,
5) At

-9 "6"--I C

=,0. ?

6) Calculations (See Below)

=

S9-2a VS/e '%> =

/0 "q-

Ž' = !S/--

e)

O -7 l9../

=A 1

C.,

/-

0

7) Restilts Q

OK Reviewer ctl/ -

., /33 Code allowable alt"6 2

Calculated WIt%

Laminar flaw surface area: (0.75 I

w)

A) Table used for analysis 6F OK Reviewer tt 3

S 2..,

e

0)

Was lbnonr Interpolation used7 CD Yes (0

No If no.

why?

4CL P

I-6& 10/8 7

  1. r&+c r2/

Z-4C

,3S'

-45 IO)

Was IWA-3200 Significant Digits For l.lmiting Values followed?

417 Yes O

No If no.

why?

11) The correct Code Edition and Addenda was available and used.

(P Yes Preparnr--t_.i J

O OK Reviewer

12) Statemcnt or acceptability or rejectability with basis.

1 OK Reviewer 0p(J O

Accept 0

Reject CO (all)

Code allowable a (alt) calculated C)

OEM

[law evaluation handbook (see attached analysis)

C)

(sit)

Code allowable (Cel) calculated

13)

Prepared by.nd patc r14ngineering r

w bA arid date The rosults are correct and the fnethodology used Is In accordance Ths1-reiiew assures that the results are correct and tIhe with applicable codes.

standards.

specifications and procedures.

methodology used Is in accordance with applicable codes.

/

stanstau.,u speciaion a81,0 procvedurer.

15) Acproved by andSato This approval assures that all Inrvfived with Jhis flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standards. specifications and procedures.

Addrtiorl - Isl Flow ROcspvriiin

.edil f rr

Setrup, Additional - Supplemental Reports <edit frtom Setup>

NM)

Supplemental Report Report No.:

2005VE019 Page:

4 of 5

Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:

II Level:

N/A Si Level:

NIA AN Reviewer: Jones, Thomas. CiM te Review: Wren, Jerry P 97-Ill Review: Daly, GeraldA Date:

Date:

8f -ca s Date: 1 b

1 P--

Comments:

Sketch or Photo: J:\\lslDatalSRPl2-05 outage\\Scans\\WeDyne Vessel Flaws\\'505018 N-7AFlaw Sizing 2.bmp NM

~>

Site/Unit:

P

/ I C

Summary No.:

50 5=0 t S3 Workasope:

rs
1) Flaw Number
2) Item Number a

E, g0 L.- e/

p

/AJ-Flaw View ISI Flaw Sizing Worksheet Procedure: Pb7-iST-OVZ/-

AZ Procedure Rev.:

Work Order No.:

9

-70

3) tSI Interval

-_A-

4) Code Edition & Addenda

/ 9W

-. 4,

5) Method

£-4

6) Flaw Sketch (See Below)
13 Outage No.:

PzAie eSS Report No.:

.?o 0-S* VE Ci Page

of dP OK Reviewer

) OK Reviower 0

OK Reviewer q i

_4 2 9

,, q c,,

b csN I I C 4-ON r

7) Calculations Q@4 OK Raviewer
8K Show determilirnution or Surface or Stibsurface Show detcrminallon r

I tpor a,

to tose SJI - A1,6 -6 7.2L

  • --S.~.

_d C>

.r

-t;

_. e.-

0)44 FE-Paragraph7-

t.

was used

@ Yes Preparr371_

J Q@ OK Reviewer

9) Code Flaw Diiesiorns (M OK Reviewer

-I0 a -

0.1

't no'nmnnl - -

't measured s -

/

V

-w

10) Flaw Type r1OK Reviewer S b e

P t 1)

Flaw Charactcrlzation Figure CO OK Reviewer 2

3 S

-/

12) Flaw Charactorizntion Figure Number

/

13) Was IWA-3300 Flaw Characterization fotlowed?

@ Yes 0

No If no. why?

14) The correct Codo Ed lion and Addenda was available and used.
15) Pr!!pareg and datol

/

The results are correct and the methodology used is in accordance with applicable codes. standards. spocificntlons and procedures.

VYos Preparer-t I

Jk

@J OK Reviewer

16) R:

e~

da e

4 A

v L

f.-

The rev assures that the results are correct and the methodology used Is in accordaice with applicable codes, standards, specifications and procedures.

Additional - ISa Fl.- S.z..ed.t fro, Seltp.

Additional - Supplemental Reports <edit from Setup>

NMl)

Supplemental Report Report No.:

2005VE019 Page:

5 of 5

Summary No.: 505018 Examiner: VENDOR, WESDYNE Examiner: N/A Other: NIA Level:

II Reviewer: Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald CV4, 5 Date:

41_/_

5 Date:,-ec+/-'o

=

_ Date:

tiAU&65 Comments:

Sketch or Photo:

J:\\lSIDataJSI\\PI2 05 outage\\Scans\\WeDyne Vessel Flaws\\505018 N-7\\law Disposition 2.bmp NMio Site/Unit.

P Zr I

fi Sunirnary No:

C>

_ O I 8 Workscope:

ISI Flaw Disposition Worksheet Procedure:

-Xs5-2ZS-Z Procedure Rev.:

O Work Order No.:

O L O Co Co 7 0 Outage No.:

rZ2

? Zz7 Report No.:

VcY15 L'

0 9

Page:

or

1) Flaw Nuinber
2) lIn& Numnber B
1.

. q I tAr z til

^_ -

3) ISI Interval
4) Code Edition & Addenda S) Acceptance Standard
6) Catculullons (See eolo-)

/F8 9 "ale' 40a.

  • OK Reviewer 52fJ N

OK Reviewer e~sXkJ I

OK Reviewer Z

4 OK Reviewer ai 09

/ 0 R

=

6../

-9/,P=-. /o

` =

9 ve-r

60.

/)/0f vl-'~

/.

0 y

=

-/

/.

q

, /,

I 0

=.0

7) Rrcs.ulls 0 OK Reviewer C;t) rnt -

D9. /0 Code ellowable eWt% -

~

Calculated tJ Y._ /

09 Laminar flaw tsurface area: (0.75 1 w) *

/) Table used for onalystn OK Revilwer ZD _e -

3 5

i

_t j

-2

0) Was linear interpolation usod?

C) Yes 0

No If no. why?

A-uo 7

"?e.2 c, l &=

10) Was IWA-3200 Significant Digits For Limiting Values followod?

0 Yes C)

No Ifrno. why?

1t) The correct Code Edition and Addenda was available and used.

Yes Preparer 7

0 O

OK Reviewer

12) Statement or auceptability or rojoctobility with basis.

D OK Reviewer (0' Accept C) Reject 1I (aft) Codo atlowahle > (WIt) calculated

  • i OEM flaw evaluation, handbook (see attached analysis)

C)

(a/1)

Code llowoable * (a0t) calculated 13J by annd o

Thle rjlsulls are correct and the methodology used Is In accordance with applicable codes, standards. specifications and procedures.

date Yhis l'ew v

sStres that the results are correct and the meth odology used is in accordance with applIcable codes.

standards. specifications nnd procedures.

15) Ap!v=d by t d\\

d ale f

v This approval assures that all lsr0tved witA thlis navw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with Vippilcable codes. standards, specifications and procedures.

Adieonel - ISI Flow D09position.edit from Selup-Additional - Supplemental Reports <edit from Setup>

REACTOR VESSEL WELD RESULTS

SUMMARY

PLANT NAME Prairie Island Unit 2

WELD NO.

N7 (505018)

COMPONENT Outlet Nozzle to Shell @ 28.50 LIMITATIONS:

NO F-1 YES 3j 78.56 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 2

NI STATUS Code Allowable RI X

EXAM DOCUMENTATION INDICATION DOCUMENTATION Lf PARAGON ANALYSIS LOG IEIASSESSMENT SHEET FxII PARAGON ACQUISITION LOG mK PARAGON HARD COPY EKI SCAN PRINT OUT

=II OTHER (Specify)

ELl COVERAGE BREAKDOWN Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.

Analyst //,

Date:

e

R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.

N7 (505018)

International COMPONENT Outlet Nozzle to Shell @ 28.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION l 45 Shear l

45 L Single 45 L Dual l Combined Bore/Star

_ WELD I VOLUME.

WELD I VOLUMEj WELD I VOLUME] WELD I VOLUME TAN Scan l

l______

Parallel 54.33 28.52 64.28 56.90 71.82 69.79 Combined Bore&Star l

l Perpendicular Il l

l

60.

99.68 l

99.35 AVERAGE 41.42 60.59 70.80 99.52 Comments:

Combined Perp.

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.

I 99.52 fAX Combined Para.

Analyst

/

/

1_7

/

57.61 Combined Average 78.56 Date

_//

/

/

/

/

/

/

6'

/

/

/

/

6'

/

(9.18)

WALL

/

/

6'

/

1/

/

/

<6

//

/

//

//

//

//

X

//

R66.00 to Transdlucer CIO.I Sled x

Package X~/'

Figure 1 26.53 Tar Coverae Illustration Primary Uuttet Nozzle Protrusion Limitation

NM -

Site/Unit:

PINGP

/

Summary No.:

5t Workscope:

Ultrasonic Examination P12

)5020 Procedure:

Procedure Rev.:

Work Order No.:

UT-Vendor 0

0406670 Outage No.:

E031 Report No.:

2005VE021 Page:

I of 7

IS' Code:

1989 Edition Cat./ltem:

B-DIB3.90 Location:

Drawing No.:

2-ISI-40

==

Description:==

Outlet Nozzle to Vessel Weld Loop B System ID:

RV Component ID: N-10 Size/Length:

NA Thickness/Diameter 9.1r153" Limitations:

See WesDyne exam report Comments:

See supplements and Refer to the applicable WesDyne report found in the book:

Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005

&78.56%, See Wesdyne final report for details.

Results:

NAD D]

IND R GEO D Indicaitons allowable by Code Percent Of Coverage Obtained > 90%:

'No Reviewed Previous Data:

NJA Examiner Level II Signature Date Reviewer (Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas

/

..Jo2df Examiner Level II Signature Date Site Review Signature Date Auer, Robert G.

Wren, Jerry P "g-e-os Other Level NIA Signature Date ANII Review Signature Date N/A Daly, Gerald 7eIQ.

sSo0r.

NM)

Supplemental Report Report No.:

2005VE021 Page:

2 of 7

Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.

Other:

NIA Level:

II Reviewer: Jones, Thomas Level:

II Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald C_ _

Date:

_S ____

q Date: £ --

7S

&Q Date: 1&4 I )

Comments:

Sketch or Photo: J:ISIData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\50502O N-10\\Flaw Sizing 1.bmp Site/Unit:

P1>

, J Stimniary No.:

S O S C

_0 O WorksCoPO:

7 SX ISI Flaw Sizing Worksheet Procedure: 2br-l.ri- ;tS4/

&.2 Procedure Rev.:

0 Work Order No-e

-,I o °

1) Flaw Number

/

2) Itein Number 2
3. 9 o
3) ISI Interval

_R-

4) Code Edition a Addenda

/ 7

./,

Xi.

5) Method
6) Flaw Sketch (See Below)

Flaw View

,A-

/

C 7

Outlao No.:

IZ~

O f Report No.:

.7O0S, V C O;/

Page:

of 9

OK Reviewer 1

0 OK Reviewer OK Reviewer

= d9 n O i

i I

I i

7) Calculations 4D OK Reviewer Show dctlrmninalion of Surface or bs 3

Show,latcrrnination or type of a

to use j

f-

  • - A C - Z-I a)ftl r-E.-4 Paragraph-7-d

_R ft t was used tP) Yes Preparer

0) Codu Flaw Oimonsionrs W OK Reviewer I

3 0

0 I nom'nnai-

c.

7

-t measurei

-d

10) Flaw Typo Q OK Reviewer 5 b

-7er

11) Flaw Characterization Figure W OK Reviewer 4 -

5

-C

12) Flaw Charactoriznlton Figure Number a

I

13) Was IWA-3300 Flaw Characterization followed?

SW Yes 0 No It no. why?

A OK Reviewer C

L

-s-o-

w-Al PI-,_

nr -

/

14) The correct Code Edition and Addenda was available end used.

0W Yes Preparer r10 OK Reviewer t S _

/

v S

16), ~

dcz.My~

and d LA,-v The results are correct and the methodology used is In accordance The re4 ssures that the results are correct and the with applicable codos. standards. specifications and procedures.

methodology used Is In accordance With applicable codes.

standards. speclfications and procedures.

A"idt.Or,0

  • ISI Flaw SizE *eddt Imron Setoup Additional - Supplemental Reports <edit from Setup>

NM)

Summary No.: 505020 Examiner: VENDOR,WESDYNE Examiner: Auer, Robert G.

Other: N/A Supplemental Report Report No.:

2005VE021 Page:

3 of 7

Level:

_I Reviewer: Jones, Thomas Level:

_1 Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald c-jrt, 1

Date: _______

Date: g-5 -;S 4

Date:

IsAiydg-(U Comments:

Sketch or Photo: J.ISIDataUSI\\P12_05 outagelScanslWeDyne Vessel Flaws\\505020 N-101Flaw Disposition 1.bmp NME>

Site/Unit:

P Z:

%Z Summary No.:

50 S0 A 0 Worksrope:

ISI Flaw Disposition Workshect

1) Flaw Number

/

2) Item Number Ei

. q 0

uae0, H-AJ X -

J Procedure: P xs4r-2 s5f-z Procedure Rev.:

O Work Order No.:

0) '-O CDeg 7 0
3) ISI Interval
4) Code Edition & Addenda

/,98 9

^/,P 470,

5) Acceptance Standard g-

$ 5'/ *;>

6) Calculations (See Below)

Outage No.:

/2Z-:Z g2 0s-Report No.:

V2rs* ViE P

/

Page:

d of es OK Reviewer OK Reviewer 4C OK Reviewer 6R OK Reviewer a

=4o Oe, J=/,

-/1, t' 0 7-7 VIe= 9-2..),

LtS-

/-

O

7) Results Q

OK Reviewer DA -

. 0 77 Code allowable avtY 2,1.

LeJ-Calculatede/t/%

1 C)7 Leaminarflawsurface area:(0.75 I w)-

.AJ'4

8) Table used for analysis l;

OK Reviewer j

=Z, r3 _- 3.s-5 I

/

9) Was linear Interpolation used?

0 Yes a

No If no. why?

10)a W

ii gceit fo Lmi Z

a

-lu ed

/e o

f no 2 IO) Was IWA-3200 Significant Digits For Limit ng Values followed?

4D Yes O:: No It no. why?

I11) The correct Code Edition and Addenda was available and used.

PYes Preparer-.,_,..J

> OK Reviewer 5hW

12) Statement or acceptability or rejectability with basis.

0 OK Reviewer

( <

Accept Q Reject (a/t) Code allowable o (a/t) calculated 0

OEM flaw evaluation handbook (see attached analysis) 0 (a/J) Code allowable (aft) calculated

13) Prepared by and Oate 14,ngtneeing re y anddt The results are correct and the methodology used Is In accordance Thisyeview assures that the results are correct and the with applicable codes. standards, specifications and procedures.

methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

IS) Apwvedby ary date This approval assures that ail Involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct end In accordance with applicable codes. standards. specifications and procedures.

Additional -11S Flaw Disposilion -edit from Setup-Additional - Supplemental Reports <edit from Setup>

NMC)

Supplemental Report Report No.:

2005VE021 Page:

4 of 7

Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.

Other: N/A Level:

II Reviewer: Jones, Thomas Level:

II Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald C< 9 Date:_____

Date: S-r-c-dQ()

Date:

Ls5Afo.6 U

Comments:

Sketch or Photo: J:\\ISIData\\ISl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Sizing 2.bmp Site/Unit:

P Z

I

.2_

Summary No.;

£54 0 p

) ° Workscope:

Z S

tSI Flaw Sizing Worksheet

1)

Flaw Number a_

2) Item Nurrmber a

9?O JA Ie/)-e Al-J O Flaw Viow Procedure:

lebr'-'

S-f'/-

A/Z Procedure Rev.:

0 Work Order No.:

2 6

?7 0

3) tSI intervat S

=5

4) Code Edition & Addenda

/ 9q'V r..

412 0

5) Method 1<J T O) Flow Sketch (See Below)

Outage No.: PXZ R f;S Report No.:

.OOS VC oC

/

Page:

of O

OK Reviewer

@ OK Reviewer

@ OK Reviewer 3.z

>O.- L t

>0.

O..

/

&?, o.3/

>.tI(A4(.

3 n -

>.t sb4cf I

i I

i I

-- ~1:.z$-Z5

?

, O./,,-

I I

I

7)

Calc,,lilions 0

OK Reviewer

.Show determination or Surface Show determination or type of a to use J.57t~?5

.5i-l - A.6 eO 7: Z s.-

8) 44 rE

. Paragrapla--

was used

9) Code Flaw Dimensions e

OK Reviewer

-I-r

  • a 0S5t nominarl 9

Z

-t

10) Flaw Type (RD OK Reviewer 7
1) Vieaw Characterizaion Figuro 6C OK Reviewer.

I 2) Flaw Characterization Figure Number

ch /
13) Was IWA-3300 Flaw Characterization followed?

0 Yes MD Yes Prep aror 7s4t. J 4S OK Revlewer

'~---

fnwosurvd

/

-s- -

3..

Z S w- -

(

s b ----

l_ cen P Ir-^e

.S s

S a

-/

O No If no, why?

14) The correct Code Edition and Addenda was available end used.

I r, Pr a

dbyaddae O 5 The results are correct and the methodology used Is in accordance with nppllcable codos. standards. specifications and procedures.

o Yes Preparer r

(,..J C

OK Reviewer

16) Re nd

=7'

-rZ 6

f 5-The revt

£t'assurcs that the results are correct and the methodology used Is In accordance with applicable codes.

standards, specifications and procedures.

Arddional. ISI Flaw Size *edil from Setupc Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE021 Page:

5 of 7

Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.

Other: NIA Level:

II Reviewer: Jones, Thomas Level:

II Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald c

)

Date:

_/_/o__

Cate:ate:

8-

&Dat:

,kW.

Date: ijs-*

L.d (2

Comments:

Sketch or Photo: J:UlSIData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Disposition 2.bmp Ni\\MeT>

Site/Unit:

P X725 /

Summary No.:

7>

-o a

Workscope:

_- 25 S=

ISI Flaw Disposition Worksheat Procedure: P. t-.r5r-

-A/.Z Procedure Rev.:

C Work Order No.:

OL.

6 O

(, C 7 0 Outage No.:

Px>2 g<zS Report No.:

20S

-Vc' g%

/

Page:

of

1) Flaw Number
2) Item, Number C;2o 3)11S interval
4) Code Edition & Addenda

/ 98 9 IVO X.19.

5) Acceptance Standard

.Z'. V S

3

t
0) Calculations (Sue Bol-w)

@0 OK Reviewer 4

Ol< Reviewer

<if OK Revlewer IC OM OK Reviewer j

=

/, L7 V

t

=

K>>

/-

D

~

O

~

7) Results 0

OK Reviewer nA -

O. 033 Code allowable aWt% -

0 4-Calculated anY.

D Laminar (law tsurfoce area: (0.75 1 w)

0) Toble used for analysis P

OK Reviewer C

.Z

- 3 S '7

9) Was linear Interpolation used?

CD Yes 0' No If no, why?

ACz c

'.e 71 -

6 C'

0el C2 /e O

IOr 7--c 1O) Wes IWA-3200 Significant Digits For Urniting Values followed?

O Yes 0

No If no. why?

11) The correct Code Edition and Addenda was evailable end used.

O Yes Preperer 7-Z J

9 OK Reviewer

12) Statement of acceptability or rejectabifity with basis.

l OK Reviewer (1np Accept C> Reject C

(a/t) Code allowable (a/lt) calculated

°D OEM flaw evaluation handbook (see attached analysis)

C)

(sl/) Code allowable ~ (a/I) calculated

13) Prepared by and ate The results are correct and the methodology used is In accordance with applicable codes. standards. specifications and procedures.

IS rng r d date

'*s This w assures that the results are correct and the methodology used is In accordance with applicable codes.

standards. speciacantlons and procedures.

1S)

Arrv d hyad date 5.9 =...'to I

This approval assures that alffinvolved with this flaw sizing and ttaw disposition were aware of the necessity thai the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.

Add-lional - ISI Flaw DOspositton -edit fromi Setup-Additional - Supplemental Reports <edit from Setup>

NMC)

Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner Auer, Robert G.

Other: NIA Supplemental Report Report No.:

2005VE021 Page:

6 of 7

Level:

II Level:

II Level:

N/A Reviewer: Jones, Thomas

° Date: _______

Site Review: Wren, Jerry P

~ Date: _-2-;

ANII Review: Daly, Gerald 4M Date:

S5&

LI Comments:

Sketch or Photo:

J:ISIData\\ISI\\PI205 outage\\Scans\\WeDyne Vessel Flaws\\505020 N-10\\Flaw Sizing 3.bmp Site/Unit.

P

/

.,?.

Surrmary No.:

5 s

O LC.)

Workscope.

r S-L
1) Fiow Number 3

?1 Item Number E3 a.

9g0 ISI Flaw Sizing Worksheet Proceduro:

?r

-_Sf-r

&,Z Procedure Rev.:

a Work Order No.:

O e4 6

i7°

3) 1St Interval 3
4) Code Edition & Addenda

/ 9 I AC 14Q.

5) Method L

`-

6) Flaw Sketch (See Below)

Flaw e/

Flavv View J-lo Outage No.:

P F

Report No.:

tO&C Vt

)

/

Page:

of CY OK Reviowor (O

OK Reviewer OK Revitewer o -

Y-a')('

C2

,0 4V-n

,/0 0 -jo I

I 11' I

___J __,_ -=_

7) Caklculwlio,,

(>

OK Rovicv..nr Show dolormination of Surface or.

ubsur Show determination of ot

'a' to use

-Ad~e->-essz 7_

  1. i54.

8)i-FE 4 Preagraph..r--

_ _I l lthoJ was used

9) Code Flaw Oimonsions 4D OK Reviewer r.

I S

a l

10 t nonwno 22

-t

10) -law Type R

OK Reviewer <

i-

11) Flaw Charricterization Figure Q9 OK Reviewer y
12) Flaw Characterization Figure Number

/

13) Was IWA-3300 Flaw Characterization followed?

O Yes 6

Yes Preparer -

op-nmees,,e'd

/Li

-s- -

s b

eC Pl,_,

4-3 3z _,-

OK Reviewer

'5=

0 No If no. why?

14) The correct Codo Edition and Addenda was available end used.

1 5) Prer by rid 1 he results are correct and the methodology used Is In accordance with applicable codes, standards, specifications and procedures.

AXICI4,nal - 131 Fl-Size.e4i froan, setup.

m Yes Preparer 7

tY OK ReviOwerK i

i 1

e= :nd-17 6 9-The rik

, assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

Additional - Supplemental Reports <edit from Setup>

NM)

Summary No.: 505020 Examiner: VENDOR, WESDYNE Examiner: Auer, Robert G.

Other: NIA Supplemental Report Report No.:

2005VE021 Page:

7 of 7

Level:

II Reviewer: Jones, Thomas aT.k

(

Date: __5_o_

Date:

S'-'

Level:

_1 Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald Date:,sr U

Comments:

Sketch or Photo: J:IlSlDataliSflP2o05 outageIScanslWeDyne Vessel FlawssO5502O N-10FIaw Disposition 3.bmp ImnhMa>

ISI Flaw Disposition Worksheet Site/Unit; P z..,

St.nmmnry No.:

C:-0 5: o. _n Workscope -

Procedure: P1 r-r-5'/-&'z Procedure Rev.:

C Work Order No.:

LvO G G 7 0 4TcD-I Outage No.-:

toZr pz f S

Report No.:

25co V'S

.2 /

Page:

of

1) Flaw Number

.3~

2) Item Number 1>'~. C90 Lu,.'

") AJ/ -/ 0 J

&-e'OI?

11

=

,7/'

/- 0.

'(

~

e1 3)151 Interval

4) Code Edition - Addenda

/ "989

.. /,4.0.0.

5) Acceptance Standard EZ i-

.5?

-/;

(3) Calculations (See Below) a?, 2'

/.

O0 <'5

<D OK Reviewer 1

OK Reviewer C

OK Reviewer a

OK Reviewer

7) Results C@ OK Reviewer aI f

Code allowable aWt%

a

2. Li-Calculated a/t%

-/_

07 Laminar flaw surface area: (0.75 1 w)

Aw B) Table used for analysis

!1 OK Reviewer

=1 J B0 - 3S'

-/

0) Was linear Inlerpolation used?

0 Yes No If no. why?

t0)

Was IWA-3200 Slgntiicanrt igilts For Linmiting Values followed?

I Yes 0 No Iflno. why?

11) Tho correct Code Editiorn and Addenda was available and used.

G Yes Preparer er77i*-

0 OK Reviewer

12) Statement of acceptability or rejoctabilltywith basis.

4 OK Reviewer 4

Accept 0

Reject (0

(all) Code allowable > (all) calculated 0

OEM flaw evaluation handbook (see attached analysis)

O (a/t) Code allowable (aWt) calculated 3I Prep bynd tal The results are correct and the methodology used Is In accordance with applicable codas. standards, specifications and procedures.

1tilnvaring Iv woy and date C) 6?L4'§' *g5 Thislaew assures that the results are correct and tha methodology used is in accordance with applicable codes.

standards. specifications and procedures.

15) A~roved byd dale.

I nle.zt 1

.3

..*vS This approval assures that alt involved with this flaw sizing and flaw disposition were aware of the necessity that the results and the nmethodology are correct and In accordance with applicable codes. standards, specifications and procedures.

Additlonal - 1tS Flaw Disposition radit fron, Setup-Additional - Supplemental Reports <edit from Setup>

REACTOR VESSEL WELD RESULTS

SUMMARY

PLANT NAME Prairie Island Unit 2

WELD NO.

N10 (505020)

COMPONENT Outlet Nozzle to Shell @ 208.50 LIMITATIONS:

NO E YES [I 78.56 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 3

NI STATUS Code Allowable RI X

EXAM DOCUMENTATION INDICATION DOCUMENTATION FU PARAGON ANALYSIS LOG

[K1ASSESSMENT SHEET LII PARAGON ACQUISITION LOG

[XI PARAGON HARD COPY m7I SCAN PRINT OUT

[I] OTHER (Specify)

LII COVERAGE BREAKDOWN Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.

Analyst

/

j Date: 6

R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.

N10 (505020)

International COMPONENT Outlet Nozzle to Shell @ 208.5° BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD I VOLUME WELD IVOLUME WELD VOLUME WELD VOLUME TAN Scan Parallel 54.33 28.52 64.28 56.90 71.82 69.79 Combined Bore&Star Perpendicular 99.68 99.35 AVERAGE 41.42 60.59 70.80 99.52 Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel). Figure 1 illustrates the obstruction.

Combined Perp.

Analyst w

I/

/

i

/

II

. I. i-I.1

/

/

/

/

/~

/~

/~

/

(9.18)

WALL

/

/

X/

R66O00 to

/

/

/

/

Cladl Sled

/

/

/

/

/

/

Transducer Package 11 Figure Tarn CoveraQe Primary ylutl Protrusion

? 1 26853 Illustration

%et Nozzle Limitation

NMl)

Ultrasonic Examination Site/Unit:

PINGP

/

Summary No.:

51 Workscope:

P12 D0727 Procedure:

Procedure Rev.:

Work Order No.:

UT-Vendor 0

Outage No.:

E031 Report No.:

2005VE023 Page:

1 of 9

ISI 0406670 Code:

1989 Edition Cat./ltem:

B-D/B3.90 Location:

Containment Drawing No.:

2-ISI-40

==

Description:==

SI Nozzle to Vessel Weld Loop A System ID:

RV Component ID: N-8 Size/Length:

NA Thickness/Diameter:

9.17"/11.58" Limitations:

See WesDyne exam report Comments:

See supplements and Refer to the applicable WesDyne report found in the book:

Prairie Island Nuclear Power Plant / Unit 2 10-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005

  • 59.26%, See WesDyne final report for details Results:

NAD D]

IND i GEO L Indications allowable by Code Percent Of Coverage Obtained > 90%:

  • No Reviewed Previous Data:

Yes Examiner Level II Signature Date Reviewer Sign ture Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas Examiner Level N/A Signature Date Site Review SignatureLv C

Date NIA Wren, Jerry P

=AAJw-Other Level N/A Signature Date ANII Review LI Signature Date NIA Daly, Gerald Iydd/ md.QS IS-,uc-OS

NM)

Supplemental Report Report No.:

2005VE023 Page:

2 of 9

Sumnmary No.: 500727 Examiner: VENDOR, WESDYNE Examiner N/A Other: NIA I

Level:

11 Reviewer: Jones, Thoma Level:

NIA Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald S

I400 Date:

_/_ __S_

Date: F-&-'oS Date:

1

\\

U' Comments:

Sketch or Photo: J:\\lSIDatalSt\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Sizing 1.bmp N lviYE-Site/Unit:

P I

.2 Summary No.:

5 e

e 7 i

'7 Worksrope:

5

1) Flow Nuitber
2) Item Number B

0o Flaw View ISI Flaw Sizing Worksheet Procedure:

ZS4/ ¢-Outogo No:

PX7,,-

1zt S

Procedure Rev.:

O Report No.:

soos V Work Order No.

S -7D 0

Page:

of

3) ISI Interval OK Reviewer
4) Code Edition & Addenda 19j

^/9, o gt4 OK Reviewer

5) Method T-r o) Flow Sketch (See Below) 4 0 OK Reviewer c&,

e v

/

,4,v s t%

2 /

0

  • .,'..:.c

-Z/;

a?

5 vi

.:=.:

_=_

.c

,.3q2 j I I

f 4, I Ck tl e OL U

7) Calculations O

OK Reviewer c_

J SI.1w det.nr liwation or Surface of ubaurfac

)

Show determination of type of -a to use

__~J

8) fZE-4 Paragraphh.1'-

ad wedwas used 0i Yes Preparer OK OReviewer

__-7>-

0) Code Flaw Dimensions 01<

OK Reviewer

. J 7-5

-a-Z o

-t noinrnoa- '

t measurod

/

s -

w NV A

10) Flaw Type 0 OK Reviewer S

h 5-.-

4,.

1t) Flaw Characterization Figure V

OK Reviewer

,4 3

S t

-/

12) Flow CharacterizatIon Flgurc Number

/

13) Was IWA-3300 Flaw Characterization followed?

< Yes 0

No If no why?

14) The correct Code Edition and Addenda was available and used.
15)

=

Fd by Aan=-,/L.-J

/

Sf >

The rSzfit aae correct and the methodology used Is In accordance with applicable codes. standards. specifications and procedures.

e Yes PreparererC.

0> Ol< RevIewer °_

1G) Rcve a

dal The review assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

Add,60enat - 131 FI.- SIX.

radiI iro., S.WLu~

Additional - Supplemental Reports <edit from Setup>

NM Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner NIA Other: NIA Supplemental Report Report No.:

2005VE023 Page:

3 of 9

i Level:

_1 Reviewer: Jones, Thoma Level:

NIA Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald S

C8-;iJ Date:

_ _/_ __

Date: 2-c-s Date:

IS4t~x;-c~

Comments:

Sketch or Photo:

J:XlSlDataUSl\\Pl2 05 outage\\ScanstWeDyne Vessel Flawst500727 N-6Flaw Disposition 1.bmp NMC j Sile/Unit:

P Z

/

i Z_

SummaryNo.:

SOO 7,> ;L Workscope:

S ISI Flaw Disposition Worksheet procedure: Ptr-5 '/-sgr-iJ'.Outaoe No.:

P:=z. jep Procedure Rev.: __

Report No.:

_200i vC5 Work Order No.:

) Lb/

Lao 7 c>

Page:

of

1) Flaw Number

/

3) ISI Interval
2) lien, N,,nher EB 3

. q 0

4) Code Edition & Addenda

/ 58 9 A/4

,4..

5) Acceptance Standard ir r-5i s5/ ).;

J6 t

U

^/

6 i6) Calculations (See Below)

O OK Reviower C

OK R.vioar C> OK Review:er pJ O

OK Reviewer 6'

60. 7Q a/p.~ g. Z6-1 t_

-2 01te '%, =

? - / -7

= 5

=

J3-2-

Ce j

/-O

7) Results O OK Roviewcta29_1L.-

nAl -

t.24"7 Code allowable ei/t% -

S.

8 Lv0'-

Calculated &lt%

L

?

Laminar flaw surface nroa: (0.75 1 w)

13) Table used for analysis
  • P OK Reviewer°

._1 Zw 3St P a 1f) Was linear Irnterpolation used?

CD Yea Ivl No If no. why?

e9 C C ec>+ P t<

4"z a

IC>'

6

l/

4e C-S 3-42E

10) Was IWA-3200 Significant Digits For Llniting Values (ollowed?

Yes 0 No If no. why?

11) The correct Code Edilion and Addenda was avallable and used.

4i Yes Prsearer 2R& t-

  • Ot Reviewer

-T-AtJ

12) Sttlement of accoplability or rejoetabilily with basis.

OK Review-r 7A.

ID Accept 0 Roject 4V (alt) Code allowable (ant) calculated

) OEM flaw evaluation handbook (see attached analysis)

C)

(a/lt) Code allow-able - (alI) calculated 1qrnd by

't

14)

Ieyng and date PM E

-r rra C

JGf 7 /_z' 5-lsulls are correct and the methodology used is In accordance This review assures that thte results are correct and the with applicable codes. standards, specifications and procedures.

methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

t5) Aqroved by anida This approval assures that all Invofvcd with this naw sizing and naw disposition were aware of the necessity that the results and the methodology are correct and In occordanco with applicable codes. standards. specifications and procedures.

Addllon.1 - ISI Fl-w Dlsrpe.llan -. dit *ron-S.top-Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE023 Page:

4 of 9

Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:

11 Reviewer: Jones, Thomas Level:

NIA Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald Date: 4k<1/os 9

t Date:

-5

-Cs a

Date: ISAL uff S L)

Comments:

Sketch or Photo: J:\\ISIDataXlSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-81Flaw Sizing 2.bmp INM Sitejunit:

P *-

i

.-2.

Summary No.:

So O.

7 Workscope:

S

1) Flaw Number
2) Item Number B

3, 9FO ISI Flaw Sizing Worksheet Procedure:

-Az

-utage No.:

PoXrz fQ S Procedure Rev.:

0 Report No.:

-?OS LEO OA5 Work Order No.:

' YD -

Page:

or

3) ISI Interval

____a O

OK Reviewer 1

4) Code Edition & Addenda

/0 9g0

,.4, O

OK Reviewer

_J

5) Method T
6) Flow Sketch (See t3elow) 0 OK Reviewer t

eI Flaw View A/-S2) s fio 3

=

7 C *.Ab

7) Calculatlons V OK Reviewer.'!S)1 Show deterninatlon of S~ure a

e-)

Show determination or type of 'a' to use

S-I e -.-

g 7-I, 7

8)-is4-FcE-4 Paragraph-r-.

.dW

' Mttj was used

9) Code Flaw Dimensions O

OK Revlewer J

-r

'7.

e' -

0V/0

't nominei

10) Flaw Type OKI Revieworc7 J

1t) Flaw Characterization Figure 4

OK Reviewerr W

12) Flaw Characterization Figure Number
$^ /

'13) Was IWA-3300 Flaw Characterization followed?

O Yes

  • P Yes Preparer i0 OK Reviewer 7

t measured' - -

s4 -'_ 3.

2.

_ o s

.- > co

=='

_~ 3

.- /

0 O No If no. why?

14) The correct Code Edition and Addenda was available and used.

I K ebto(/-Uj a

a SfS 5

The Ivults are correct and the methodology used Is In accordance with applicable codes. standards. specfications and procedures.

AddifleOrI - 151 Fltw Si.. '.dit fr e Ct.ip.

  • 9 Yes Preparer C
  • OK RovilWewerI4.
16) Rw adeI The review assures that the results are correct and the methodology used Is In accordance With applicable codes.

standards. specifications and procedures.

Additional - Supplemental Reports <edit from Setup>

NM&)

Supplemental Report Report No.:

2005VE023 Page:

5 of 9

Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:

11 Reviewer: Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald

-=Tz24-Date:

_/_/_s Date:

Y Date: 15SAu,4c Comments:

Sketch or Photo:

J:\\lSlData~lSltPl2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Disposition 2.bmp Site/Unit:

P :Z

/

Summary No.:

4 7

3 n Workscope:

2 S ISI Flaw Disposition Worksheet Procedure: P0-Zsr-5'!-s tPlOutaoo No.:

/4lo I

Procedure Rev.:

Report No.:

2Csa5 L/6- 0 Work Order No.:

O

-v 0 eo (, 7 0 Page:

of

1) Flaw Number
3)

ISI Interval

2) Item Number B 3. q? 0 A) Code Edilion & Addenda
5) Acceptance Standard f,

,. /6 ff

) -

6, e) Calculations (See Below)

/5989

"-Vo

.Z'-&V L-

% 5./ aR

  • OK Roviawer 40 K Reviewer

-1 O OK Reviewer 4

OK Rnviewar 6'9 =9

~/ 0 j/=

e2,-'7 -

/'

/3.3 ef = 9 - :Z Vlt, = eq, t,/ 0 a 7 vle -Z' = /' 09

3. 7s-/0,

/,o S ~,7

~'-,Vcr

7) Results
  • OK Revieer r¶i.

A a/t -

-.9

/ -3 Code allowable a/t% -

.?. 5-Z-s Calculated alrt

/. 09 Laminar flaw surface area: (0.75 1 w) _

I) Tablo used for analysis O

OK Revlewer-7%=

J J.,.

Bt - 3 1

t -,

9) Was linear Interpolation used?

) Yes 0

No If no, why?

xe eL -e

' Ak b Ce.

'e

ico, c

o _

/t.

.r S

C--

10) Wos IWA-3200 Significant Digits For Limiting Values followed?

<0 Yes 0 No If no. why?

11) Tho correct Code Edition and Addenda was avaliable and used.

a Yes Preparer 4P OK Reviewer

12) Statement of acceptability or rejectabilily with basis.

J0 OK Reviewer J

0 Accept O Reject Ql (n/) Code allowable > (n/t) caiculalOd 0 OEM flaw evaluation handbook (see attached analysis)

C) (a/t) Code allowable f (a/t) calculated t

mppred by anddato,

14) Enginooring revig by nnd date
4 d b y Cgd d a v.

__ _0__

The results are correct and the methodology used Is in accordance This review assures that the results are corroect and the with applicable codes. standards. speceficntions nnd procedures.

methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

1 S) Areoved by nd date

  • This approval assures that atl.nvolved with this naw sizing and flaw disposition were awaro of the necessity that the results and tho methodology are correct and in accordance with applicable codes. standards. specificatlions and procedures.

Adddhonal - 1t1 Flaw Olsposition "dit from Setup-Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE023 Page:

6 of 9

Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: N/A Other: N/A Level:

11 Reviewer: Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald

_____),

Date:

Date:

IM Date:

IeSAL-&GqgS L)

Comments:

Sketch or Photo: J:MlSIDataXdS\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-80Flaw Sizing 3.bmp SiteiUnlt:

p Z

/

Summary No.:

-:V O

9 a 7 Workscope:

.2 S

ISI Flaw Sizing Workshteet so I

Procedure:

r

/zOutage No.:

PXz

,-S Procedure Rev.:

o Report No.:

OO.S VI C--2 3

Work Order No.:

e eTg5-6P -7 ;0 Page.

of I

I

1) Flaw Number 3
2) Item Number B
23. 9o lw V w e

/t-S Flaw VI.-

3) ISt Interval S -e
4) Code Edition & Addenda 1 9i?

o/

As2.

5) Method

.4 T-

6) FIDw Sketch (See Oelow) 11 I C 1

It.

OK Reviewer

  • OK Reviewer OK Reviewer

-f~e O0 0-3

-Z 0,

,, 5

' a O

^ - s, s

7) Calculations C OK Reviewer 7A. J Show dctermnlratlon of Surlflco orgftissurtac.g>

Show determination oft e oI 'n to use 5 3 S A b e7. '

X -

' 4 )

r.

- A

".A -

I

8)

-r-E-,

Paragraph7-a-4'o..a zrr i..t:

was used

@ Yes Preparer 5

tO OK Rerviewer

______J_

9) Code Flaw Dimensions v

OK Reviewer 4

, ;2 O

5

°

'a

'O.

10

-t nominal

'i1 measured' -

=

M

/

73 v-v-A/l

10) Flaw Type
  • & OK Reviewer i

J b t

_.4&.

e-

.- P.

I1) Flaw Characterizatbon Figure C OK Reviewer

=

4 -

S 5:

12) Flaw Charecterization Figure Number a

/

13) Was IWA-3300 FIJw Choracterizatiorn followed?

0 Yes 0 No If no, why?

14) The correct Code Edition and Addonda was avaliable and used.

Q Yen Preparcer !5!e 1105Praparbd Oyd LiV.

e v

10) Review bysad date J The results are correct and the methodology used Is In accordance The review assures that the res with applicable codes. standards. speclncEllons and procedures.

methodology used is In occorda standards. spectficotions and p.

AIditlonal - IS Flaw Size *edt trfn. Setup' O OK Reviewer-=wie. A sults are correct and the inca with applicable codes.

rocoduras.

Additional - Supplemental Reports <edit from Setup>

NMC)

Supplemental Report Report No.:

2005VE023 Page:

7 of 9

Summary No.: 500727 Examiner: VENDOR, WESDYNE Level:

_1 Reviewer: Jones, Thomas Examiner: N/A Other: NIA Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald 9f4i_ &Date:

S_____

S )

Date: ___

JI Date: KA CS Comments:

Sketch or Photo: J:\\lSIData\\iSI\\P12_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Disposition 3.bmp N

M PZ ISI Flaw Disposition Worksheet Site/Unit:

P Z

/

fit_

Procedure: P-.br :r-Z -5/-So-tV.Outage No.:

P.2f7s SummaryNo.:

s o

7a 7 Procedure Rev.:

__)

Report No.:

VOaS*Vt e'._

3 Workscope:

Z-5 Work Order No.:

6 L.o

(,( G 7 0 Page:

of

1) Flaw Number 3
3) [SI Interval OK Reviewer
2) Item NLumber B& 3..

0 o

4) Code Edition & Addenda

/ 989

/;

4O 0 0

OK Reviewer CJ

5) Acceptance Standard t

g-5 ST / ;

OK Rovtower

-_2 0

O) Calculations (See Below) b OK Reviewer c

l9 6

'!. / O t=

9 _'r =-

5 0

87 VXp =l O g,//{

o-

/

9 7 3 3,73/

, /o

=

3 7, 3

7) Results 0

OK Reviewer oD -

. 09' Code allowable at%

e 0

1A ZColcutalad a/t% -

L O

Laminar now surface area: (0.75 I w) -

8) Table used for analysis 0 OK RevIewor 2;;_

%t3-3

-,;R-,

.)) Was linear Inlorpolntlon used?

0 Yes O No if no. why?

10) Was IWA-3200 Significant Digits For Limiting Values followed?

C Yes O No It no. why?

1t) The correct Code Edition and Addenda was available and used.

0 Yes Preparer 5

Z2 7 OK Reviewor -7Z;J

12) Statement of acceptability or rejectability with basis.

0 OK Reviewer Q_ Accept C Reject Ot (C/t) Coda allowable C (alt) calculated 0 OEM nfw,valtuaton handbook (see attached analysis)

C)

(alt) Code allowable *c (Cat) calculated The TSults are correct and the methodology Used Is In accordance with applicable codes, standards, specifications and procedures.

14) Englnooino review bynd date This review assures that the results are correct and the methodology used Is In accordance with applIcable codes.

standards. specifications and procedures.

1S) Approveyd by ar

`

dale_

rO

_I I

i

- I!,

i)

^-.7

v<

This approval assures that all Inlved with this naw sizing and flaw disposition were aware or the necessity that the results and the nielhodology are correct and In accordance with applicable codes. standards, specifications and procodures.

Addillorwl - 151 Fle.v Disposition -edit freom SetuP-Additional - Supp!emental Reports <edit from Setup>

N M6)

Supplemental Report Report No.:

2005VE023 Page:

8 of 9

Summary No.: 500727 Examiner VENDOR, WESDYNE Examiner N/A Other: N/A Level:

11 Reviewer Jones, Thomas Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald sZ 4 <<ii D ate: _ _ _ _ _/

2/7 Date:

P-s- -cr <5 Date:

ISA LI Comments:

Sketch or Photo: J:%ISIData\\lSl\\Pl2_05 outage\\Scans\\WeDyne Vessel Flaws\\500727 N-8\\Flaw Sizing 4.bmp NM >

SltefUnlt:

P 7

/

-2.

Summary No.:

5 0 7.l 7 Workscope:

S-2

[SI Flaw Sizing Workshect

1) Fln_ Number
2) Item Numher 411/

a~

3.90g Procedure:

.bE_-7

.-,fO tageNo.,

P: zJ/ f Procedure Rev.:

Report No.:

.oos V C2; 3

Work Order No.:

,:9 e i

70 Page:

of

3) JSI Inkerval S0 OK Reviewer
4) Cockd Edition & Addenda J

s4,

$4

_ Y OK Reviewer J

5) Method C4 -r
0) Flaw Sketch (See Feloew)

G) OK Reviewer LA,,-

0 Flaw View I

qjg.

f, %.0,

c

_f

/.0 O

25~

'/

r5 5., --c

7) Calculations O OK Reviewer Show determination of Surface o$&urracei)

Show determination of tye of a to use 7.2 syes prO..-

+

4 OKReviewor 8)-t4-FE-I ParagraphEC-S o -p -f' fi At-i-was used 6t Yes

____Rv e

9) Code Flaw Dimenslons 40 OK Reviewer -77XJ 1-

-n-O_

09. ' 0 t nominal

+/--I '

,s

.sured O

-w- _

t

10) Flaw Type O OK Reviewer T.°C-5 P
11) Flaw Characterization Figure C

OK Reviewer J

A -

5. 3

.2-

_ /

12) Flew Characteizatlion Figure Numbor

^

/

13) Was IWA-3300 Flow Characturizatioi followed?

a Yes 0 No If no. why?

14) The correct Code Edition and Addenda was avevllable and used.

15 r

b ad

-7 L.'J, l r

7 8 The r are correct and the methodology used Is in accordance with applicable codes, standards. specifications and procedures.

(

Yes Preparer f

  • OK Reviewer 1-t--'..

1i) Revle k

dcat,!J4 X//2 The review ossures that the results are correct and tle methodology used Is In accordance with applicable codes.

standards. specifriations end procedures.

Addj,0 -

1~.

M5 Ftla, Six... d~t trol r S.I.,p.

Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE023 Page:

9 of 9

Summary No.: 500727 Examiner: VENDOR, WESDYNE Examiner: NIA Other: N/A Level:

II Reviewer Jones, Thomas Level:

NIA Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald Date:

s d4M Date: iSAocct LI Comments:

Sketch or Photo: JAISIDatallSl\\P12_05 outage\\Scans\\WeDyne Vessel FlawsX500727 N-8\\Flaw Disposition 4.bmp Site/Unit:

P Z

/

Summary No.:

fTQQ -

7, 7

Workscopo:

.5

=-S ISI Flaw Disposition Worksheet e of0 I

Procedure: Pbz7-xsr-

. 5-s-- tPZOrta;i No PZr% eF -;

!S Procedure Rev.:

C)

Report No.:

Vc0s Vd/

e.) 3 Work Order No.:

O L/O C >

7 0 Page:

of I

i I

1) Flaw Numbor
2) tlem Nu1mber I/

'B ---5. - C? 40

3) ISI interval

_Q

4) Code Edition & Addenda

/98

" O/a d"

5) Acceptance Standard

& g'-

3 a'7.

6) Calculations (See Lietow) 0 OK Reviewer Q)

OK Reviewer J

oC OK Reviewer

-rnv, S

C0 OK Roviewer

-r7-,,, S) 16' =

9. /a Y

1=

- 0 aV/

1p -

./ Q 0/' -Z e9- 0187 vle 7- =

/'

0 7 r(=

s/s' 0

o z

7) Results O OK Reviewer ai -

O.

/0 Code allowable a/t%

.5 Calculated o/t%

7...

Laminar flaw surfaco aren: (0.75 1 w) tt) Table used for analysis Qt OK Reviewer J

w a

-t - /

0) Was linear irlterpolation usod?

0 Yes V No If no. Why?

.- /6,-'

Re e C-.,

-- Z-elO

10) Was IWA-3200 Significant Digits For Limiting Values followed?

C) Yes 0 No Ir no, wtTy?

11) Tho correct Code Edition and Addenda was available and used.

t-Yes Preparer C ) OK Reviewer J

12) Staternent of acceptability or rojectabillty with basis.

0 OK Reviewer 4_

3 0

Accept 0 Reject 4

(a/t) Code allowable >- (a/t) calculated 0

OEM flow evaluation handbook (see attached analysis) 0 (tit) Corde nilawahble (sit) calculated

13) fby 8ng

,L....JL-

/

8-The r sare correct and the methodology used Is In accordance with applicable codes, standards. spocificatlons and procedures.

14) Enjiineorina review by and date

//

This review assuros that the results are correct and the methodology used Is In accordance with applicable codes.

standards, specifications and procedures

15) Apoved by ardate This approval assures that alfinvolved with this naw sizing and naw disposition were aware of the necessity that tlha results and the methodology are correct and In accordance with applicable codes, standards, specifications and procedures.

Addillonal - 151 Flaw DlsposItIon 'Odit fron Setup-Additional - Supplemental Reports <edit from Setup>

REACTOR VESSEL WELD RESULTS

SUMMARY

PLANT NAME Prairie Island Unit 2

WELD NO.

N8 (500727)

COMPONENT Safety Injection Noz-Shell @108.50 LIMITATIONS:

NO 1

YES 3j 59.26 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 4

NI STATUS Code Allowable RI X

EXAM DOCUMENTATION INDICATION DOCUMENTATION 37I PARAGON ANALYSIS LOG mEASSESSMENT SHEET El PARAGON ACQUISITION LOG EKII PARAGON HARD COPY FLE SCAN PRINT OUT

= OTHER (Specify)

LKII COVERAGE BREAKDOWN Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).

Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.

l t Analyst b,,

ate:

5

R.V. COVERAGE ESTIMATE BREAKDOWNS PLANT NAME Prairie Island WesDyne WELD NO.

N8 (500727)

International COMPONENT Safety Injection Noz-Shell @108.5° BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD I VOLUME IWELD lVOLUME WELD I VOLUME WELD I VOLUME TAN Scan Parallel 15.55 57.14 0.00 53.66 0.00 28.10 Combined Bore&Star Perpendicular 97.40

88. 15 AVERAGE 36.35 26.83 14.05 92.78 Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).

Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.

Combined Perp.

92.78

_pObined Para.

I 25.74 Analyst

'- +1-I

Figure 1 Tan Coverage Illustration of the Safety Injection Nozzle

NM)

Ultrasonic Examination Site/Unit:

PINGP /

Summary No.:

5 Workscope:

P12 00726 Is' Procedure:

Procedure Rev.:

Work Order No.:

UT-Vendor 0

0406670 Outage No.:

E031 Report No.:

2005VE024 Page:

1 of 7

Code:

1989 Edition Cat./ltem:

B-DIB3.90 Location:

Containment Drawing No.:

2-ISI-40

==

Description:==

SI Nozzle to Vessel Weld Loop B System ID:

RV Component ID: N-11 Size/Length:

NA Thickness/Diameter 9.17"/11.58" Limitations:

None Comments:

See supplements and Refer to the applicable WesDyne report found in the book:

Prairie Island Nuclear Power Plant / Unit 2 1 0-Year Reactor Vessel Inservice Examinations Interval 3, Period 3, Outage RF023 2005

  • 59.26%, See Wes Dyne final report for details.

Results:

NAD D IND i GEO Percent Of Coverage Obtained > 90%:

  • No Reviewed Previous Data:

Yes Examiner Level II Signature Date Reviewer Signature Date VENDOR, WESDYNE 5/15/2005 Jones, Thomas i&1/ G.J-5/S Examiner Level N/A Signature Date Site Review Signature v

Date NIA Wren, Jerry P e

Vt/l-..--

Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald

NM)

Supplemental Report Report No.:

2005VE024 Page:

2 of 7

Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner: NIA Other: NIA Level:

_1 Reviewer: Jones, Thomas Level:

NIA Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald d 5 Date: _______

Date: ___

Date:

1 Comments:

Sketch or Photo: J:UlSIData\\ISI\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1\\FIaw Sizing I.bmp N

Slte/Unit:

P

/

B.2 Summary No.:

-5 OO 7 a L.

Worksoope:

.Z*

ISI Flaw Sizing Worksheet Procedure:

X-Aot No.:

PX.<

Re fO-Procedure Rev.:

a Report No.:

?oC5 VF Work Order No.:

e SzO6,( 2;70 Page:

of

1) Flaw Number
2) Item Number a/ag 6: tj I
3) ISI Interval
4) Code Edition & Addenda J 9IVY

,v X.

6) Method ri
0) Flaw Sketch (See Delow)

Flaw View P OK Revlewer O

OK Reviewer

-W OK Reviewer

.L =0l ' ao

<O.

- 4A O.

=

'o.1 4' J'r

>D.Zz 4

o Z

R

,/

et. -

.3 0

7) Calculations O OK Reviewer Show determination of Surface 3

Show determination of t e or a to use

..J' I -AM1, e - #'e -' I

'Z gVg,;4ts.. 3 t 4.--

8)4B4-v-4Par 7-7 ;

-- 4PZ ws s

8) lMI FE. Paragrapha-7-.

Ir* r was used C

Yes Preparer !Z E

J

@) OKI

9) Code Flaw Dimensions M OK Reviewer

° r- _

'Q

'a' -

5 00 I nominal - -

_9..

-t

,rreasured -

q.

nZ

10) Flaw Type O

OK Reviewer rl4k

_5 b

'.. s -*

P

^_

t 1) Flaw Characterization Figure 0

OK Reviewer

-7 J,4 3

. S

- /

12) Flaw Characterization Figure Number a

/

13) Was IWA-3300 Flaw Characterization followed?
  • " Yes 0 No If no. why?

Reviewer w

5ds

14) The correct Code Edition and Addenda was avaliable and used.
15) P by ar 7-/B -os'*

The resu 4 are correct and the methodology used is In accordance with applicable codes, standards, specifications and procedures.

Addftional - ISI Flaw Size -edit from Setup' Co Yes Preparer "ZjP4

'11 OK Reviewer -71% j

16) Reve bv a:~

7ate IO 5-The review assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specifications ancd procedures.

Additional - Supplemental Reports <edit from Setup>

NM)

Summary No.: 500726 Examiner: VENDOR, WESDYNE Supplemental Report Report No.:

2005VE024 Page:

3 of 7

Level:

11 Reviewer: Jones, Thomas Examiner NIA Other: NIA 9-xs J Date: *6 A'17T a2E Date:,-a-c, Level:

NIA Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald Abr)

Date: ILAu&o U'

Comments:

Sketch or Photo:

J:ulSIData\\ISI\\P12 05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-i 1\\Flaw Disposition 1.bmp NFLVID SlterUnit:

P Z'

/

Summary No.:

goo 7

Worksoope:

ISI Flaw Disposition Worksheet Procedure: Pb r

5!

s-- tJOutage No.:

Pz'Z /ex Procedure Rev.: __

Roport No.:.0oos dVC 40 S/o Work Order No.:

4 C-`0 Co o 7 0

Page:

of

1) Flaw Number

/

2) Item Number B

2. ?

0 LA I-L_ *,

d t

3) ISI Interval
t
4) Code Edition & Addenda

/ 98 9 A/a '4"'

5) Acceptance Standard El 1
s.
2
0) CalculatIons (See Below) 0 OK Reviewer q-Z2k J 4D OK Reviewer c,

J I

OK Reviewer 7

Z OK Roviewer 6 -

0, J=

1,0

/,p 0'. 30 e-=

9-2...

-7e-=e9. 0-32 4 '

r K 1_7 t /,/

'/

K9.' 30 ~-_

L...es C_

- 0

7) Results 0

OK Reviewer

.-1 =

.0. 5 0 Code allowable a/t% -

C/, */

Celculated ent%

Z a) Table used (or analysts AW O< Reviower x

J J a-3S _,R I; i

fi) Was linear Interpolation used?

C) Yes 4

No If rno. why?

1 Ws A g avt itcr L mit-ng V o

ed 1

Ys

10) Was IWA-320z0 Signtricant Digits For Limiatingf Vniues followed?

til Yes O5 Lamninar nlw surface area: (0.75 I w) 4 No Ir no. why?

t 1) The correct Code Edition and Addenda was available and used.

O Yes Preparer

  • 4 OK Reviewer J J
12) Statement of acceptability or rejectability with basis.

0 OK Reviewer -

J Accept I= Reject li (a/t) Code allowable > (alt) calculated C) OEM flaw evaluation handbook (see attached analysis)

CO (0/I) Code allowable.

(n/t) calculaled 13),Proppred by d P Ii g---,

12__ RI 5-Thresults are correct and the methodology used Is In accordance with applicable codes. standards. specilications end procedures.

14) Engineering rev w byan date 7

This review assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specincatlons nnrt procedures.

15) Ap
pydbyarilda This approval assures that al involved with this flaw sizing end lnow disposition were aware of the necessity that the results and the methodology are correct and in accordance with applicable codes. standords. specificatIons and procedures.

Adictonal - ISI Flaw ilsposltion edal frrom Setup>

Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE024 Page:

4 of 7

Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:

N/A Other: N/A Level:

11 Reviewer: Jones, Thoma Level:

N/A Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald S

'=,

_J Date:

SZa Date:

A-&

--, S ffi Date:

%Aut,<§ L)

Comments:

Sketch or Photo: J:\\ISlData\\lSl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-11\\Flaw Sizing 2.bmp Site/Unit:

p:

r-1 Summary No.:

00 e R

Workscxpe:

a 5:r ISI Flaw Sizing Workshicet Procedurc:

-r22/

Outage No.:

PX°2Z.

C F s~ s Procedure Rev.:

a ReportNo.:

.,0OS v 0r Work Order No.:

e9 D£<

70 Page:

of

1) Flaw Number
2) Item Number a

90

3) ISI interval

_g_ _

4) Code Edition & Addenda

/ 9q 4,,4,7Y

5) Method qt T (3) Flaw Sketch (See Below)

Fl w. /VQe Flaw vie_

A/-

//

I 1----..--.--.--....--

O,

I it

.=

O.

9, 1,9 "

I

--I 4

Is.

-g "

a

%V OK Reviewer-na,

& OK Qeviewer O

OK Reviewer ov-

/= z

7) Calculatlons O

OK Reviewer 7

Show determinatIon of Surface o

Show determination oftype oI Ia to use Ir -Ad6

'-C F-C

'6 s-4-...#

8)+40-FB-4 Paragraph-7cr. -

-f 1...I J was used

9) Coda Flow Dimonsions O OK Revlewer9f-..J

_1_

O" 7

n--

. Z It notmnai

-t

10) Flow Type C OK Reviewer 1 1) Flaw Characterizalion Figure O OK Reviewer C

j

12) riow Characterization Figure Number

/

13) Was IWA-3300 Flaw Characterization followed?
  • Yes C

Yes Preparer C

0 OK Roviewor J tnens-rod l

a -r

.9 7

S -

C P

Ot-r C

2 4-3 3aBrt

/

0 No If no. why?

14) The co-reut Code Edition and Addenda was availablo e nd used.

15!

re rad by a1 y

iL L,_

1 The rAultS are correct and the methodology used Is In accordance with upplicutble codes, standards. specincations and procedures.

Arlrt-tionaI.

SI Flew Size <ed-l fon, Sehtup 41 Yes Preparer (

OK Reviewer z2-

/

16)

Revo Obv-dVt

-172,1/D5 The rerview assures that thlr results are correct and the methodology used Is In accordcance with rpplicable codes.

standards. specifications and procedures.

Additional - Supplemental Reports <edit from Setup>

NM)

Supplemental Report Report No.:

2005VE024 Page:

5 of 7

Summary No.: 500726 Examiner VENDOR, WESDYNE Examiner. NIA Other. NIA Level:

11 Reviewer: Jones, Thomas Date:

__/5 Level:

N/A Site Review: Wren, Jerry P Level:

NIA ANII Review: Daly, Gerald J4dC~

Date:

F_ ?:i b;

Date: I6AL64c U

Comments:

Sketch or Photo: JAISIData\\ISI\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1XFlaw Disposition 2.bmp Pi M >

She/Unit:

P ZX i

Summary No.:

5 C;)

-7.A t Workscope:

2 ISI Flaw Disposition Worksheet Procedure:

P-..ra r-2 pJLOutago No.:

P 2 2e O Procedure Rev.:

Report No.:

l zo-5 Ve Od I Work Order No.:

O Z' 0 (z e 7 0 Page:

°'of

1) Flaw Number o;z
2) Item Number B3. 4? 0 6

C L d

4 ti I

3) 1SI Interval A) Code Edition a Addenda

/7 8 g o

AO

5) Acceptance Standard R-5!t $. / i
6) Calculations (See Below) 1 OK Reviewer Ct O

O1K Reviewer 7_

@ OK Reviewer C____

O OK Reviewor 6'2 -

J~ =

O-7.5 V/

33 3

Vlte'

=

2. -7 2-r

=

=

/7-5"7-a Z

15 e- "$c5

/-

'e

7) Rusults O

OK Reviewer J

?,-

.33 3 Code allowable n/t% -

V-. V 4Za4Calculated atl% -

.2' -7.2

13) labte used for analysis o

OK Reviewer'

Z-e

- 3 5_ I-

-I

9) Was linear Interpolation used?

o Yes O

No It no. why?

1 ) W.3 SC

- ig i i n Di gi C-eF o L m i V l e o Jl o e ?

es

10) Wns IWA.3200 Significant Digits For Limiting Values followed?

O0 Yes O)

Laminar naw surface area: (0.75 1 w).

^/4 ce -

4-/, '/

No It no. why?

11) The correct Coda Edition and Addenda was available end usad.

@ Yes Preparer 0

OK Reviewer c,

J

12) Statement of acceptability or rejectabilitywlth basis.

O OKRoviewer

-1

/

Accept 0 Reject

!L (alt) Codo allowable > (aft) calculated O

OEM flaw evaluation handbook (see attached analysis) o (alt) Code allowable e (Wit) calculated 13teaoared b sid crite a

Tl 1Msults are correct end the methodology used Is In accordance with applicable codes. standards. specifications and procedures.

14) Engineering reviewby nnd date This review assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specifications and procedures.

1 5) Approved by ante t

  • I o: t'4w _w b ° 0-This approval assures that all Innoived with this flaw sizing and flaw disposition were aware of the necessity that the results and the methodology are correct and In accordance with applicable codes. standards. specirications and procodures.

AOCtdtiorol - ISt Fta-DlsPoslltin -edit tram, 5*1uP-Additional - Supplemental Reports <edit from Setup>

NME )

Supplemental Report Report No.:

2005VE024 Page:

6 of 7

Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:

N/A Other: NIA t

Level:

11 Reviewer: Jones, Thoma Level:

NIA Site Review: Wren, Jerry P Level:

N/A ANII Review: Daly, Gerald s

ti-Date:

Date: e-S; -L(.-

Date: _67AC66r A<n

"-1*rl C-Comments:

Sketch or Photo: J:\\lSlData\\ISl\\PI2_05 outage\\Scans\\WeDyne Vessel Flaws\\500726 N-1 1Flaw Sizing 3.bmp Site/Unit:

Op r

/

Summary Na.:

5C70 71 to Workscope:

Z

.1' 7

1) Flaw Number

.3

2) Item Number B

'j70 ISI Flaw Sizing Workslhieet Procedure:

PZ-1sr-C/-,5Z--NeOutage No.:

P:.2?-J rfAtoS Procedure Rev.:

O Report No.:

No V

t E f

Work Order No.:

e:

& -7 0 Page:

of

3) tSI lntervel S _R 0

OK Reviewer

4) Code Edition & Addkanda

/ 979 34 4

@ OK Reviewer c

J

5) Method tf

-r'

6) Flaw Sketch (See Below)

Vt OK Reviewer c

_t Flaw View A-. -

}/

I I_

i I

- _T q"t



.2 4

>1 0.

-/

Z_

-P =



y 0 -I/

../ X M. eq I 0 (a 1.

.r.'r.5 >. /.o -A.-

Z.,_-Zr..

/.

&'/

>a.

0(' = '.

b

1. - c-e ck =.
X

CL ek

=

P,

-.5-

7) Calculations At OK Reviewer Show determination of Surface oiZubsufVe\\

Show determination of type of -a' to use J

IA s,

E) 44rr-FE-4 Paragraph-7-. -

R

-a

¶.:I J was used O Yes Preparer OK Reviewer

0) Coda Flaw Dtnmensions A0 OK Reviewer

____j___

7 a2 5_

Lt nons,7,t0

.2 --._

meepsured -

/

-w-

10) Flaw Type CD OK Reviewer I

S

1.
5.

..4,,..

P e-p

11) Flaw Characterization Figurr At OK Ravlower J

C Z

.o 4 _

3 3

/

12) Flaw Characterizaton Figure Number

/

13) Was IWA-3300 Flow Charactcrizalion fotlowed?
  • Yes 0 No If no, why?
14) The correct Code Edition end Addenda was available and used.

!5Pp red bYd c,

,L

.7-2-

The results are correct and the methodology used Is In accordance with applicable codes, standards. specifications and procedures.

e Yes Preparer G0 OK RevIewer l7J.4

16) Revw bnnd dale C

J C7/_-2j,

/p The review assures that the results are correct and the methodology used Is In accordance with applicable codes.

standards. specifications end procedures.

Add~tienal - ISt Flws Sir* -edit Iron r-..P~

Additional - Supplemental Reports <edit from Setup>

NMC)

Supplemental Report Report No.:

2005VE024 Page:

7 of 7

Summary No.: 500726 Examiner: VENDOR, WESDYNE Examiner:

NIA Level:

11 Reviewer: Jones, Thomas c=r J

Date:

Level:

N/A Site Review: Wren, Jerry P 9 o)

Date: _ '__ __

Date: I 1AL,&6S Other: NIA Level:

NIA ANII Review: Daly, Gerald U-Comments:

Sketch or Photo: J:lSIDatalSl\\Pl2o05 outage\\ScansNWeDyne Vessel Flaws\\500726 N-1 1\\Flaw Disposition 3.bmp Site/Unit.

t

/

I Summary No.

5, O

o

a.

C-Workscope:

2-S ISI Flaw Disposition Workshect Proceduro: PbZ-.sl-As/f--

tJl-Outage No.: Prs Procodure Rev.:

C)

Report No.:

Voos_ VC eOJ V Work Order No.:

4 9

O Co te 7 0

Page:

of

1) Flaw Number
2) itemi Numbar 3;

'E

. C? o 3)tSt IInterval

4) Code Edition & Addenda

/ F89

./t /a AA7

5) Acceptance Standard Zt&V a-T S / E;2 G) Calculations (See s3olow) q9 OK Reviewer f

OK Reviewer C

J M

OK Reviewer e_l 7

OK Reviewer

~

O- / 7S J

-=

!V,-7 e-=

17 -

2)

-/Y

=- O.

O le,&-

/G3 g = -5/1, = /.(Oa3 /0,

=.

O,

/0I L. 5 C--

/.

C

7) Results OK Reviewer 3

n

- g 7. 2Z 0

Code allowable aft% -

3 - 3 Calculated a/t% -

/,

6 -3

0) Table used for analysis

'0, OK Reviewer

,J

zr e -

3 5-t

-/

0) Was linear interpolation used?

C Yes fP No Of no. why?

-AS i t a a

L i m i in a

u e f O sllo e dY

10) Was IWA^-3200 Significant Digits For Limitling Values followved?

a Yes C)

Laminar now surface area: (0.75 1 w) -

No If no. why?

I 1) The correct Code Edition and Addenda was available end used.

0 Yes Preparer r7_0

12) Statoment of acceptability or rejectability with basis.

0 OK Reviewer "

J a

Accept

@ (ant) Code allowable a (alt) calcultled 0

OEM flow evaluation handbook (see attached analysis)

C) (aft) Code allowable c (alt) calculated C OK Reviewer

-7 0

Reject

.,d.gy zv 7-IS-oS-results are correct and the methodology used is in accordance with applIcable codes. standards. specifications and procedures.

14) a Terin revie by and do te

.z 7

5 This review assures that the results are correct and the methodology used is In accordance with appiloble rodes.

standards. specifications and procedures.

15) Ap roved bynd dtol

/O

-1 t

nsl1 approval assures thatie involved with this law sizing and naw disposition were aware oo the necessity that the results and the methodology are correct and In accordance with applicable codes, standards. specifications and procedures.

Addt.t.l

- ISO Fla-DO,.posillo,, '-dil from Saluo4 Additional - Supplemental Reports <edit from Setup>

REACTOR VESSEL WELD RESULTS

SUMMARY

PLANT NAME Prairie Island Unit 2

WELD NO.

Ni1 (500726)

COMPONENT Safety Injection Noz-Shell @ 288.50 LIMITATIONS:

NO Fj YES [I 59.26 % Complete See Coverage Breakdown Sheet RESULTS NO. OF INDICATIONS 3

NI STATUS Code Allowable RI X

EXAM DOCUMENTATION INDICATION DOCUMENTATION

[!JPARAGON ANALYSIS LOG EXIASSESSMENT SHEET WE1PARAGON ACQUISITION LOG E-7IPARAGON HARD COPY 3Fl SCAN PRINT OUT

[=IOTHER (Specify)

WCOVERAGE BREAKDOWN Comments:

Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, and the Tan Scan (parallel).

Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.

Analyst Date:

PLANT NAME R.V. COVERAGE ESTIMATE BREAKDOWNS Prairie Island WesDyne WELD NO.

N11 (500726)

International COMPONENT Safety Injection Noz-Shell @ 288.50 BEAM ANGLE BREAK DOWN BEAM DIRECTION 45 Shear 45 L Single 45 L Dual Combined Bore/Star WELD VOLUME l WELD lVOLUME WELD IVOLUME l WELD lVOLUME TAN Scan l

l lllll Parallel 15.55 57.14 0.00 53.66 0.00 28.10 l ll Combined Bore&Star Perpendicular 97.40 88.15 AVERAGE 36.35 26.83 14.05 92.78 Coverage calculation is based on the Bore and Star scan (combined) as perpendicular, Comments:

and the Tan Scan (parallel).

Figure 1 illustrates the obstruction to scanning, the nozzle protrusion.

Combined Perp.

Analyst 92.78 Combined Para.

AA In

-1 f

e 25.74 Combined Average 59.26 Date

  • /) 5kS

Figure 1 Tan Coverage Illustration of the Safety In jection Nozzle

REV.

TRF.O 4-0o 1 8 NORTH

  1. 22 STEAM GENERATOR CONT ON DWG 2-ISI-33C l

CONT ON DWG 2-ISI-33B CONT ON DWG 2-IS1-31 so.

CONT ON DWG 2-ISI-19 ON DWG 1-20A WELD 5 DETAIL WELD 1 DETAIL WEST

= WELD NO.

REACTOR COOLANT LOOP

//B //

XH-1 XH-1 REF: XH-1 001-388 001 -1182 106-7028 IFILE NO:2133ARO1 NS'P(M&SP)-PI-2 l:-

sd' DWN: DMN CHKD k, B APPD: Y6MUjt SYSTEM:REACTOR COOLANT LINE: 29 2RC-1B IDWG:

2-ISI-33AI REV: 02

N)

Site/Unit:

PINGP /

Summary No.:

Workscope:

UT Pipe Weld Examination P12 501137

[SI Procedure:

Procedure Rev.:

Work Order No.:

SWI NDE-UT-11 0

0406678 Outage No.:

E031 Report No.:

2005U036 Page:

1 of 5

Code:

1989 Edition Cat./ltem:

B-F/B5.70 Location:

Containment Drawing No.:

2-ISI-33A

==

Description:==

50 Red Elbow-Nozzle System ID:

RC Component ID: W-5 Size/Length:

2.0"/110" Thickness/Diameter:

2.9"/29"ID Limitations:

See Supplements StartTime:

15:20 Finish Time:

16:08 Examination Surface:

Inside M Outside i Surface Condition: Blended Lo Location:

TDC Wo Location:

Centerline of Weld Couplant:

Sonotrace 40 Batch No.:

  1. 02243 Temp. Tool Mfg.:

PTC Instruments Serial No.:

P11l Surface Temp.:

86

  • F Cal. Report No.:

2005CA034, 2005CA035, 2005CA036 AngleUsed 0

45 1 45T 1 60 N/A l

N/A Scanning dB 42.0 84.0 80.0 N/A NIA N/A Indication(s):

Yes D No i Scan Coverage:

Upstream i Downstream a CW Ri CCW i Comments:

Scanned at reference due to excessive noise @ +6 dB. 0° exam performed by J. Timm - Exam start 00:23, exam end 04:00 on 5123105 Results:

NAD i IND a GEO Percent Of Coverage Obtained > 90%:

No Reviewed Previous Data:

Yes Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.

512212005 Hailing, David A.

Examiner Level II Signature Date Site Review Signature Date Timm, Jeremy T.

5/23/2005 Wren, Jerry Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald

NM) 0

`0 -

O Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:

PINGP /

P12 Summary No.:

501137 Workscope:

ISI Procedure:

SWI NDE-UT-11 Procedure Rev.:

0 Work Order No.:

0406678 Outage No.:

E031 Report No.:

2005U036 Page:

2 of 5

45 deg Scan 1 Scan 2 Scan 3 Scan 4 100.000 0.000 100.000 100.000

% LengthX

% LengthX

% Length X

% Length X 100.000 0.000 67.690 67.690

% volume of length / 100 =

% volume of length / 100 =

% volume of length / 100 =

% volume of length / 100 =

100.000 0.000 67.690 67.690

% total for Scan I

% total for Scan 2

% total for Scan 3

% total for Scan 4 Add totals and divide by # scans =

78.460

% total for 45 deg Other de- -

(to be used for supplemental scans)

The data to be listed below is for coverage that was not obtained with the 45 deg scans.

Scan 1 Scan 2 Scan 3 Scan 4

% LengthX

% LengthX

% LengthX

% LengthX

% volume of length / 100 =

% volume of length / 100 =

% volume of length / 100 =

% volume of length / 100 =

% total for Scan 1

% total for Scan 2

% total for Scan 3

% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 78.460

% Total for complete exam Site Field Supervisor Date:

Additional - Calculation Pipe <edit from Setup>

Supplemental Report Report No.:

2005U036 Page:

3 of 5

Summary No.: 501137 Examiner: Blechinger, Todd P.

Level:

Ill Reviewer Halling, David A.

Date:

Examiner: Timm, Jeremy T.

Level:

Ill Site Review: Wren, Jerry Date:

Other: NIA Level:

NIA ANII Review: Daly, Gerald Date:

Comments: W-5 Coverage Plot Sketch or Photo: J:\\lSIData\\lSI\\Pl2_05 outage\\Scans\\2005U036 501137 coverage plot.jpg

~~~~~~~~~~&1- :- :,.:. -.-:.--:

'- ' ~/..

I.'

Additional - Supplemental Reports <edit frm Setup>

..,..7.:

NMP-Supplemental Report Report No.:

Page:

Summary No.: 501137 Examiner: Blechinger, Todd P.

Examiner: Timm, Jeremy T.

Other NIA 2005U036 4

of 5

Date:

Date:

Date:

Level:

IlIl Reviewer. Hailing, David A.

Level:

IlIl Site Review: Wren, Jerry Level:

NIA ANII Review: Daly, Gerald Comments: Limitation sketch W-5. No scans on nozzle side due to configuration.

Sketch or Photo: J:AISIData\\ISI\\P12_05 outage\\Scans\\2005U036 Limitation Sketchjpg W.

PKi

edr i

Additional - Supplemental Reports <edit from Setup>

NMC)

Supplemental Report Report No.:

Page:

Summary No.: 501137 Examiner: Blechinger, Todd P.

Examiner: Timm, Jeremy T.

Other: N/A 2005U036 5

of 5

Date:

Date:

Date:

Level:

Ill Reviewer: Halling, David A.

Level:

Ill Site Review: Wren, Jerry Level:

N/A ANII Review: Daly, Gerald Comments: W-5 Limitation Photo SketchorPhoto:

J:\\ISIData\\ISIXP12 05outage\\Photos\\TODD\\5-25\\DSCO1640.JPG Additional - Supplemental Reports <edit from Setup>

.Mmv.

H.U4-l CONT ON DWG 2-ISI-10B EL. 699'-O 1/4" as EL. 718'-9 5/8" NORTH INTEGRAL ATTACHMENT WES 0

I EL1

= HANGER NO.

= WELD NO.

= BOLT NO.

= VALVE NO.

REF: XH-1 106-2550 IFILE NO:2110AR05 8" RHR TAKEOFF LOOP "A" HOT LEG 1\\S(

MSP)-P1-2 I S.I DWN: CADWorksCHKD: UL-APPD:

9, SYSTEM:RHR TAKEOFF L INE: 8-2RH-lA. 8-2RC-15A

_DWG:

2-ISI-10A IREV: 06

'MC >

Site/Unit:

PINGP /

Summary No.:

UT Pipe Weld Examination P12 Procedure:

Procedure Rev.:

SWI NDE-UT-16A Outage No.:

E031 Report No.:

2005U024 501953 1

Workscope:

ISI Work Order No.:

0406678 Page:

1 of 5

Code:

1989 Edition Cat./ltem:

B-J/B9.11 Location:

Containment Drawing No.:

2-ISI-10A

==

Description:==

Valve to Pipe System ID:

RH Component ID: W-11 Size/Length:

.9" /27" Thickness/Diameter:

.812" /8" Limitations:

See Supplements Start Time:

14:20 Finish Time:

14:40 Examination Surface:

Inside E Outside i Surface Condition: Flat Topped Lo Location:

TDC Wo Location:

Centerline of Weld Couplant:

Sonotrace 40 Batch No.:

  1. 02243 Temp. Tool Mfg.:

PTC Instruments Serial No.:

Pill Surface Temp.:

71

°F Cal. Report No.:

2005CA025, 2005CA026, 2005CA027 Angle Used 0

45 45T 60 60 RL l NIA Scanning dB NIA 36.0 36.0 43.0 59.0 N/A Indication(s):

Yes El No i Scan Coverage:

Upstream E Downstream ia CW i CCW i Comments:

Single sided exam - exam performed through 100% of code volume, however procedure not qualified for detection on far side. Best effort exam on far side volume.

No scans on valve side due to configuration.

Results:

NAD i IND []

GEO C Percent Of Coverage Obtained > 90%:

No Reviewed Previous Data:

N/A Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.

5/19/2005 Hailing, David A.

5/23/2005 Examiner Level II Signature Date Site Review Signature Date Jensen, Arlen 5/19/2005 Wren, Jerry 5/2412005 Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald 5/27/2005

NM7I) aN.M Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:

PINGP /

P12 Summary No.:

501953 Workscope:

ISI Procedure:

Procedure Rev.:

Work Order No.:

SWI NDE-UT-16A 1

0406678 Outage No.:

E031 Report No.:

2005U024 Page:

2 of 5

45 den Scan 1 88.920

% Length X 44.460 Scan 2 88.920

% Length X 44.460 Scan 3 100.000

% Length X 50.000 Scan 4 100.000

% Length X 50.000

% volume of length / 100 =

% volume of length / 100 =

% volume of length / 100 =

% volume of length /100 =

39.534

% total for Scan 1 39.534

% total for Scan 2 50.000

% total for Scan 3 50.000

% total for Scan 4 Add totals and divide by # scans =

44.767

% total for 45 deg Other deg -

(to be used for supplemental scans)

The data to be listed below is for coverage that was not obtained with the 45 deg scans.

Scan I Scan 2 Scan 3 Scan 4

% LengthX

% LengthX

% LengthX

% LengthX

% volume of length /100 =

% volume of length /100 =

% volume of length / 100 =

% volume of length / 100 =

% total for Scan 1

% total for Scan 2

% total for Scan 3

% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 44.767

% Total for complete exam Site Field Supervisor Date:

Additional - Calculation Pipe <edit from Setup>

Am,,Supplemental Report Report No.:

2005U024 Page:

3 of 5

Summary No.: 501953 Examiner Blechinger, Todd P.

Examiner. Jensen, Arlen Other: N/A Level:

Ill Reviewer Halling, David A.

Level:

11 Site Review: Wren, Jerry Level:

N/A ANII Review: Daly, Gerald Date:

5/2312005 Date:

512412005 Date:

5/27/2005 Comments: W-11 coverage plot Sketch or Photo: J:lSIData\\ISI\\P12_05 outage\\Scans\\2005UO24 501953 coverage plot.jpg L.

b.......

. L.

IH-

1. -...

H.-. -

...I....r Additional - Supplemental Reports <edit from Setup>

N -)

Supplemental Report Report No.:

Page:

Summary No.: 501953 Examiner: Blechinger, Todd P.

Examiner: Jensen, Arlen Other: NIA 2005U024 4

of 5

Date:

5/2312005 Date:

5124/2005 Date:

5/27/2005 Level:

IlIl Reviewer: Hailing, David A.

Level:

II Site Review: Wren, Jerry Level:

NA ANII Review: Daly, Gerald Comments:

No upstream exams due to valve body taper. Integral attachment limits downstream exam @ 2700 for 3".

Sketch or Photo: J:%lSlData\\lSI\\Pl2_05 outage\\Scans\\2005U024 501953 limitation diagram.jpg

,. 0

.: 0 3-?".-V...

PA',.,: ',

,I 1.

Additional - Supplemental Reports <edit from Setup>

NMl6)

Supplemental Report Report No.:

Page:

Summary No.: 501953 Examiner: Blechinger, Todd P.

Examiner: Jensen, Arlen Other:

N/A 2005U024 5

of 5

Date:

5123/2005 Date:

5124/2005 Date:

5/27/2005 Level:

Ill Reviewer: Halling, David A.

Level:

II Site Review: Wren, Jerry Level:

N/A ANII Review: Daly, Gerald Comments: W-11 limitation photo Sketch or Photo:

J:lSIData\\ISI\\P12 05 outage\\Photos\\TODD\\5-19\\DSCO1549.JPG Additional - Supplemental Reports <edit from Setup>

flE'V'A TRF 4-018 NORT

\\

t,

/ 7 INTEGRAL ATTACHMENT

= HANGER

= WELD NO.

  • 3L 7ST7 M)

I cU) l co REF:XH-1 106-48 IFILE NO:2147BRO4 ISP(M&sp-PI-2 ISI DWN: DMN CHKD:LC o APPD:

SYSTEM:MAIN STEAM LINE: 6-2MS-2. 30-2MS-2.

31-2MS-2 DWG:

2-ISI-47B IREV: 05

NMC-Site/Unit:

PINGP /

Summary No.:

Workscope:

UT Pipe Weld Examination P12 500814

[Si Procedure:

Procedure Rev.:

Work Order No.:

SWI NDE-UT-1A 1

0406679 Outage No.:

E031 Report No.:

2005U023 Page:

1 of 4

Code:

1989 EditIon Cat./item:

C-F-21C5.80 Location:

Aux Bldg Drawing No.:

2-ISI-47B

==

Description:==

Tee to Flange System ID:

MS Component ID: W-14ILSU Size/Length:

1.8" /68" Thickness/Diameter:

1.75" I N/A Limitations:

See supplements Start Time:

10:15 Finish Time:

10:30 Examination Surface:

Inside E Outside i Surface Condition: Ground Flush Lo Location:

TDC East Side Wo Location:

Centerline of Weld Couplant:

Sonotrace 40 Batch No.:

  1. 02243 Temp. Tool Mfg.:

PTC Instruments Serial No.:

P111 Surface Temp.:

62

¶F Cal. Report No.:

2005CA021, 2005CA022 Angle Used 0

45 45T 60 N/A N/A Scanning dB N/A l44.0 44.0 48.0 NIA NIA Indication(s):

Yes El No 0 Scan Coverage:

Upstream i Downstream n CW R CCW i Comments:

No downstream scan on flange side due to configuration.

Results:

NAD Ej IND El GEO a_

Percent Of Coverage Obtained > 90%:

No Reviewed Previous Data:

Yes Examiner Level Ill Signature Date Reviewer Signature Date Blechinger, Todd P.

5117/2005 Tlmm, Jeremy 5/25/2005 Examiner Level Il Signature Date Site Review Signature Date Jensen, Arlen 5/17/2005 Wren, Jerry 512512005 Other Level N/A Signature Date ANII Review Signature Date N/A Daly, Gerald 6121/2005

....7..

Nmr,,-

Determination of Percent Coverage for UT Examinations - Pipe Site/Unit:

PINGP /

P12 Summary No.:

500814 Workscope:

ISI Procedure:

Procedure Rev.:

Work Order No.:

SWI NDE-UT-IA 1

0406679 Outage No.:

E031 Report No.:

2005U023 Page:

2 of 4

45 deg Scan 1 Scan 2 Scan 3 Scan 4 52.900

% Length X 52.900

% LengthX 100.000

% Length X 100.000

% LengthX 100.000 100.000 96.800 96.800

% volume of length / 100 =

% volume of length /100 =

% volume of length /100 =

% volume of length / 100 =

52.900

% total for Scan 1 52.900

% total for Scan 2 96.800

% total for Scan 3 96.800

% total for Scan 4 Add totals and divide by # scans =

74.850

% total for 45 deg Other deg -

(to be used for supplemental scans)

The data to be listed below is for coverage that was not obtained with the 45 deg scans.

Scan I Scan 2 Scan 3 Scan 4

% LengthX

% LengthX

% LengthX

% LengthX

% volume of length / 100 =

% volume of length /100 =

% volume of length / 100 =

% volume of length / 100 =

% total for Scan 1

% total for Scan 2 total for Scan 3

% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 74.850

% Total for complete exam Site Field Supervisor:

Date:

Additional - Calculation Pipe <edit from Setup>

Supplemental Report Report No.:

2005U023 Page:

3 of 4

Summary No.: 500814 Examiner. Blechinger, Todd P.

Level:

Ill Reviewer: Timm, Jeremy Date: 5/25/2005 Examiner. Jensen, Arlen Level:

II Site Review: Wren, Jerry Date: 5/25/2005 Other. N/A Level:

N/A ANII Review: Daly, Gerald Date:

6/2112005 Comments: W-14 Coverage plot Sketch or Photo: J:%lSlDataISl\\Pl2_05 outage\\Scans\\2005U023 500814 coverage plot.jpg

- S l

n r <e Set

-'.-.:.S..........:-: : :.:.::'..:.,...................................

/:

Ad.inl.upeetaeot <edit6 f-o Setup

NM76)

Supplemental Report Report No.:

2005U023 Page:

4 of 4

Summary No.: 500814 Examiner: Blechinger, Todd P.

Examiner: Jensen, Arlen Other: N/A Level:

liI Level:

II Level:

N/A Reviewer: Timm, Jeremy Site Review: Wren, Jerry ANII Review: Daly, Gerald Date:

5125/2005 Date:

5/25/2005 Date:

6/21/2005 Comments: W-14 Limitation photo No downstream scan due to Flange configuration.

Upstream exam limited for 17" at 0° & 15" at 180° due to support interference.

CW & CCW scans limited for 12" at 0° due to support Interference.

Sketch or Photo: J:\\lSIData~ISI\\PI2_05 outage\\Photos\\TODD05-17 TB\\DSC01443.JPG J:\\lSIData\\ISl\\PI2_05 outage\\Photos\\TODDN05-17 TB\\DSC01444.JPG Additional - Supplemental Reports <edit from Setup>

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION I>PX t

a

-?NFO AT1

- S-X Procedure may be performed from memory.

Userremains responsible forprocedure adherence.

Procedure should be available, but not necessarily at the work location.

O.C. REVIEW DATE:

OWNER:

EFFECTIVE DATE NR T. Downing 4/19105

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:

LIMITATIONtS To NDESWI NDE-LTS-1

,LIMITATIONS TO NDEREV:

I

.;..Page 2 of 13 1.0 PURPOSE This procedure provides instruction for identifying, quantifying and recording of limitations encountered while performing NDE examinations under the ISI program.

2.0 REFERENCES

This procedure complies with the applicable portions of the following referenced documents:

2.1 Nuclear Regulatory Commission Regulatory Guide - 1.150 "Ultrasonic Testing of Reactor Vessel Welds during Preservice and Inservice Examinations", (Rev. 1 dated Feb. 1983).

2.2 Code case N-460 - Alternative Examination Coverage for Class 1 and Class 2 Welds - Section Xl, Division 1.

2.3 Procedure SWI NDE-NDE-1, 'Equipment, Personnel and Material Reporting."

2.4 5AWI 14.6.0 "ISI Examination Program" 3.0 APPLICABILITY 3.1 This procedure is applicable to examinations performed at Prairie Island Nuclear Generating Plant.

3.2 This procedure is to be followed when it has been determined that there is a limitation which prevents obtaining full coverage of an area or volume as stated by the applicable examination procedure.

For ultrasonic examinations, this would mean less than all of the required scans and/or a reduction of required scan path for one or more scans.

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:

SWI NDE-LTS-1 LIMITATIONS TO NDE REV:

1

-iPage 3 of 13 4.0 DEFINITIONS 4.1 Limitation - something that limits, restraint: An obstacle to the performance of an examination procedure.

4.2 Evaluation - to determine the significance, worth, or condition of, usually by careful appraisal and study.

4.3 Practical -" of, relating to, or manifested in practice or action: not theoretical or ideal; concerned with voluntary action and ethical decisions. Useful." For this application this is interpreted to mean, for a specific case the benefits of a proposed action outweigh the negative aspects of that action.

5.0 PREREQUISITES Personnel Requirements 5.1 Examination personnel certification and eye examinations SHALL be documented in accordance with SWI NDE-NDE-1.

5.2 Nondestructive examination personnel SHALL be certified to a minimum of Level I in the appropriate method to operate equipment and Level II to interpret test results.

6.0 EQUIPMENT This item is not applicable to this procedure. If alternate methods are required to augment coverage, that work SHALL be done under a separate procedure.

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION r

T NUMBER:

SWI NDE-LTS-1 LIMITATIONS TO NDEREV:

Page 4 of 13 7.0 INSTRUCTIONS 7.1 Initial Examination Where the examiner is not able to complete a full examination as dictated by applicable procedure, the following steps SHALL be taken:

7.1.1 Complete original examination on accessible portions.

7.1.2 Make sketch which includes dimensions defining location and size of limitations using a report format similar to that shown in Figure 3.

7.1.3 Describe the limitation including what it is and how it interferes with the exam. State what appears to be required to remove the limitation using a report format similar to that shown in Figure 3.

7.1.4 For volumetric examinations, construct a surface profile using a surface contour gauge and perform a thickness profile (typically one reading each 1/2" in a line) of the area that encompasses the code required volume. For UT that would include the available scanning surface.

7.1.5 Record radiation field information on the report (this may require assistance from the health physics group).

7.1.6 Sign and date the data sheet then forward it to the NDE Level IlIl.

7.2 Evaluation 7.2.1 The data gathered by the initial examiner SHALL be reviewed by the NDE Level Ill or/ designee to determine if alternate methods may be used to achieve additional coverage.

7.2.2 If alternate methods would provide additional coverage, a review of the benefit versus the required resources (radiation dose, time, cost etc.) to achieve that coverage SHALL be performed by the NDE Level Ill to determine if that action is practical (see Step 7.3).

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:

I

_P a g e 5 o f 1 3 7.2.3 If it is determined that the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%.

The applicable examination records SHALL identify both the cause and percentage of reduced examination coverage (see Step 7.4).

7.3 Alternate Methods to Achieve Coverage 7.3.1 For surface examinations, MT and PT may be interchanged / intermixed as appropriate to the material and the conditions.

7.3.2 For volumetric examinations, RT may be substituted for or augment UT assuming the ability to drain the line, and that the wall thickness / diameter is within a practical range.

7.3.3 For UT, use of other angles, full node or node and one half calibrations, skewed scans or approach from another surface to achieve additional coverage SHALL be considered.

7.4 Determining Coverage Achieved When evaluation of initial and alternate examination methods results in examinations, which do not provide full coverage, a determination of percent coverage SHALL be made. The required examination coverage is defined by applicable figures in ASME Sect Xl.

7.4.1 For surface examinations, a worksheet similar to that shown in Figure 4 SHALL be completed.

i For ASME Section Xl appendix Vill exams, code coverage

,may be limited by what the procedure has been demonstrated.

7.4.2 For volumetric examinations, a worksheet similar to that shown in Figure 5 or Figure 6 (ultrasonic examinations) SHALL be completed.

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION SWI NDE-LTS-1 REV:

1 Page 6 of 13 7.5 Should the evaluation show that 90% weld coverage has been achieved, attach all related information to the original NDE report and no further action is required.

7.6 Contractor procedures for performing examinations utilizing automated equipment (e.g. reactor vessel and nozzle safe-end exams) SHALL be reviewed by an NDE Level IlIl in the appropriate method to ensure the requirements for identifying, quantifying and recording of limitations encountered are adequately addressed.

7.7 When it has been determined that the maximum examination coverage practically achievable for a code required item is less than required; a relief request is required to be submitted to the NRC (5AWI 14.6.0).

8.0 ACCEPTANCE CRITERIA This item is not applicable to this procedure.

9.0 REPORTING 9.1 Information addressed in Figures 3, 4, 5 and 6 (as applicable) SHALL be reported.

9.2 Information for examinations that are required to meet Reg. Guide 1.150 SHALL also include the following from Appendix A - Alternate Method:

7.c

'The best estimate of the portion of the volume required to be examined by the ASME Code that has not been effectively examined such as volumes of material near each surface because of near-field or other effects, volumes near interfaces between cladding and parent metal, volumes shadowed by laminar material defects, volumes shadowed by part geometry, volumes inaccessible to the transducer, volumes affected by electronic gating, and volumes near the surface opposite the transducer. Sketches and/or descriptions of the tools, fixtures and component geometry which contribute to incomplete coverage should be included."

9.3 Reference System Recording of limitations SHALL be based on the reference system shown in the original examination procedure.

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION 9.4 Documentation A picture of the limitation should be taken and added to the description, preferably in a digital format.

10.0 RECORDS 10.1 Inservice inspection examinations SHALL be incorporated in the ISI records. See UISI Examination Program."

10.2 Records of other examinations SHALL be the responsibility of the organization requesting the examination.

11.0 ATTACHMENTS 11.1 Figure 1 - Example of UT Scan Coverage 11.2 Figure 2-Example of UT, One Sided Exam, Supplemental Coverage 11.3 Figure 3 - Limitation Data Sheet 11.4 Figure 4 - Determination of Percent Coverage for Surface Examinations 11.5 Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe 11.6 Figure 6 -

Determination of Percent Coverage for UT Examinations -Vessels 12.0

SUMMARY

OF SIGNIFICANT CHANGES 2.1 Deleted ASME Code year, covered with 5AWI 14.6.0.

5.1 Changed SWI NDE-0 to SWI NDE-NDE-1.

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 1 - Example of UT scan coverage I--

C"',

b.-

a>

<D E

E CD

9 a)a

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 2 - Example of UT, One Sided Exam, Supplemental Coverage 0

0

.)

z _-

0)2 a)

C)

-to 9

& o-

>)

.-0

.4.-

a.

0 E

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION stt.-

,8

i.

i-s, t

A

^NUMBER:

SWI NDE-LTS-1 LIMITATIONS TO NDEREV:

I Page 10 of 13 Figure 3 -Limitation Data Sheet TITLE:

Limitations to NDE NUMBER:

SWI NDE-LTS-1 Revision 0 Figure 3 Limitation Data Sheet Initial exam report #

ISO #

Procedure #

Item #

Description of Limitation Sketch of Limitation Limitation removal requirements Radiation field ExaminerD Date:

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 4 -Determination of Percent Coverage for Surface Examinations TITLE:

Limitations to NDE NUMBER:

SWI NDE-LTS-1 Revision 0 Figure 4 Determination of Percent Coverage for Surface Examinations This is a sample form only Initial exam rpt #

Procedure #

ISO #

Item#_

Applicable Code figure #

Area Required (as shown in applicable code reference drawing)

Length

  • Width

= Total area required square inches Coverage Achieved Area examined sq. in. /Total area required (100%)

sq. in.

= Percent coverage

% (area required - area of limitations = area examined)

To determine length of a circumferential weld Note - Diameter refers to actual external diameter not pipe size (see table below)

Diameter

  • (Pi) 3.1416

= Length inches Pipe Actual (Length)

Pipe Actual (Length)

Size Diameter Circumference Size Diameter Circumference 2

2.375 7.46 12 12.75 40.06 2.5 2.875 9.03 14 14.0 43.98 3

3.5 11.0 16 16.0 50.27 3.5 4.0 12.57 18 18.0 56.55 4

4.5 14.14 20 20.0 62.83 5

5.563 17.48 22 22.0 69.12 6

6.625 20.81 24 24.0 75.40 8

8.625 27.10 30 30.0 94.25 10 10.75 33.77 I

NDE Level IlIl:

Date:

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION NUMBER:

SWI NDE-LTS-1 LIMITATIONS TO NDE REV:

v Page 12 of 13 Figure 5 - Determination of Percent Coverage for UT Examinations -Pipe TITLE:

Limitations to NDE NUMBER:

SWI NDE-LTS-1 Revision 0 Figure 5 Determination of Percent Coveraqe for UT Examinations - Pipe This Is a sample form onlv Initial exam rpt #

Procedure #

ISO #

Item #

Applicable Code figure #

45 deg Scan 1

% length X

% volume of length /100 =

% total for Scan 1 Scan 2

% length X

% volume of length /100 =

% total for Scan 2 Scan 3

% length X

% volume of length /100 =

% total for Scan 3 Scan 4

% length X

% volume of length / 100 =

_ % total for Scan 4 Add totals and divide by # scans =

% total for 45 deg Other deg -

(to be used for supplemental scans)

The data to be listed below is for coverage that was not obtained with the 45 deg scans.

Scan I

% length X

% volume of length / 100 =

% total for Scan 1 Scan 2

% length X

% volume of length / 100 =

% total for Scan 2 Scan 3

% length X

% volume of length / 100

% total for Scan 3 Scan 4

% length X

% volume of length /1 00 =

% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine;

% total for complete exam Example -45 deg scan 1 = 63% plus supplemental 60 deg scan I = 28% (of remaining required scan volume) for total of 91% coverage for scan 1 volume. Repeat for the remaining scans, add together and divide by the # of scans (typically 4).

NDE Level III:

Date:

NDE Level Ill:

Date:

PRAIRIE ISLAND NUCLEAR GENERATING PLANT SECTION WORK INSTRUCTION Figure 6 - Determination of Percent Coverage for UT Examinations -Vessels TiTLE:

Limitations to NDE NUMBER:

SWI NDE-LTS-1 Revision 0 Figure 6 Determination of Percent Coverage for UT Examinations - Vessels This is a sample form only Initial exam rpt #

Procedure #

ISO #

Item Applicable Code figure #

0 deq Planar Scan

% length X

% volume of length / 100 -

% total for 0 deg 45 deg Scan 1

% length X

% volume of length /100 =

% total for Scan 1 Scan 2

% length X

% volume of length /100 =

% total for Scan 2 Scan 3

% length X

% volume of length / 100 =

% total for Scan 3 Scan 4

% length X

% volume of length / 100 =

% total for Scan 4 Add totals and divide by # scans =

% total for 45 deg 60 deg Scan I

% length X

% volume of length / 100 =

% total for Scan I Scan 2

% length X

% volume of length / 100 =

% total for Scan 2 Scan 3

% length X

% volume of length / 100 =

% total for Scan 3 Scan 4

% length X

% volume of length /100 =

% total for Scan 4 Add totals and divide by # scans =

% total for 60 deg Percent complete coverage Add totals for each angle and scan required and divide by # angles to determine;

% total for complete exam Note: Supplemental coverage may be achieved by use of other angles / methods. When used, the coverage for volume not obtained with angles as noted above shall be calculated and added to the total to provide the percent total for the complete examination.

NDE Level III:

Date:

NDE Level Ill:

Date:

-