{{#Wiki_filter:SOUTHERN CALIFORNIA                                                     A. Edward Scherer Director VNuclear       Regulatory Affairs An EDISON INTERNATIONAL Company June 19, 2008 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
{{#Wiki_filter:SOUTHERN CALIFORNIA A. Edward Scherer Director VNuclear Regulatory Affairs An EDISON INTERNATIONAL Company June 19, 2008 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555


==Subject:==
==Subject:==
Line 21: Line 21:


==Dear Sir or Madam:==
==Dear Sir or Madam:==
San Onofre Nuclear Generating Station Unit 2 entered Mode 4 on January 12, 2008 following the completion of an inspection of steam generator tubes during the Cycle 15 Refueling Outage. Technical Specification (TS) 5.7.2.c states "A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program."
San Onofre Nuclear Generating Station Unit 2 entered Mode 4 on January 12, 2008 following the completion of an inspection of steam generator tubes during the Cycle 15 Refueling Outage. Technical Specification (TS) 5.7.2.c states "A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program."
Accordingly we have attached the required report. The report contains no new commitments.
Accordingly we have attached the required report. The report contains no new commitments.
If you require any additional information, please contact Clay Williams at (949) 368-6707.
If you require any additional information, please contact Clay Williams at (949) 368-6707.
Sincerely, Attachment cc:       E. E. Collins, NRC Regional Administrator, Region IV                                         A (- /
Sincerely, Attachment cc:
E. E. Collins, NRC Regional Administrator, Region IV A (- /
N. Kalyanam, NRC Project Manager, San Onofre Units 2, and 3 G. G. Warnick, NRC Senior Resident Inspector, San Onofre Units 2 & 3 P.O. Box 128 San Clemente, CA 92674
N. Kalyanam, NRC Project Manager, San Onofre Units 2, and 3 G. G. Warnick, NRC Senior Resident Inspector, San Onofre Units 2 & 3 P.O. Box 128 San Clemente, CA 92674


Inspection of Steam Generator Tubes                                                               Attachment Special Report                                                                                 Page 1 of 13 SPECIAL REPORT         - INSPECTION OF STEAM GENERATOR TUBES Regulatory Reporting Requirements Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-10 requires a report of steam generator tube inspections to be submitted to the Nuclear Regulatory Commission within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program.
Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 13 SPECIAL REPORT - INSPECTION OF STEAM GENERATOR TUBES Regulatory Reporting Requirements Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-10 requires a report of steam generator tube inspections to be submitted to the Nuclear Regulatory Commission within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program.
The report shall include:
The report shall include:
: 1. The scope of inspections performed on each SG,
1. The scope of inspections performed on each SG,
: 2. Active degradation mechanisms found,
: 2. Active degradation mechanisms found,
: 3. Nondestructive examination techniques utilized for each degradation mechanism,
: 3. Nondestructive examination techniques utilized for each degradation mechanism,
Line 41: Line 41:
Inspection Scope Table 1 summarizes the scope of inspections performed on each SG. Also, when indications by the bobbin probe were non-quantifiable or distorted, the inspection scope included inspection with the Plus Point Probe. There were no significant inspection scope expansions in response to inspection results.
Inspection Scope Table 1 summarizes the scope of inspections performed on each SG. Also, when indications by the bobbin probe were non-quantifiable or distorted, the inspection scope included inspection with the Plus Point Probe. There were no significant inspection scope expansions in response to inspection results.


Inspection of Steam Generator Tubes                                                       Attachment Special Report                                                                           Page 2 of 13 TABLE I - Scope of Inspections Performed: Unit 2 Cycle 15 (U2C15) Refueling Outage SG E-088     SG E-089 Inspection Scope Tubes/Percent Tubes/Percent Full length of tube with the bobbin probe (excluding sleeved regions, tube section below sleeves and U-             8093/100%     8224/100%
Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 13 TABLE I - Scope of Inspections Performed: Unit 2 Cycle 15 (U2C15) Refueling Outage Inspection Scope SG E-088 Tubes/Percent SG E-089 Tubes/Percent Full length of tube with the bobbin probe (excluding sleeved regions, tube section below sleeves and U-8093/100%
8224/100%
bends for Rows 1-3)
bends for Rows 1-3)
Hot leg expansion transition of unsleeved tubes at the top-of-tubesheet with the Plus Point Probe to an extent         7934/100%   8127/100%
Hot leg expansion transition of unsleeved tubes at the top-of-tubesheet with the Plus Point Probe to an extent 7934/100%
of 4 inches above to 13 inches below the top-of-tubesheet Cold leg expansion transition at the top-of-tubesheet with the Plus Point Probe to an extent of 2 inches               8093/100%   8224/100%
8127/100%
above to 13 inches below the top-of-tubesheet U-bend regions of Rows 1, 2, and 3 with both mid-               179/100%     171/100%
of 4 inches above to 13 inches below the top-of-tubesheet Cold leg expansion transition at the top-of-tubesheet with the Plus Point Probe to an extent of 2 inches 8093/100%
frequency and high-frequency Plus Point Probes U-bend regions of Rows 4 through 10 with the mid-                 90/22%       90/21%
8224/100%
above to 13 inches below the top-of-tubesheet U-bend regions of Rows 1, 2, and 3 with both mid-179/100%
171/100%
frequency and high-frequency Plus Point Probes U-bend regions of Rows 4 through 10 with the mid-90/22%
90/21%
frequency Plus Point Probe (Note 1)
frequency Plus Point Probe (Note 1)
Plus Point Probe examination of tube support intersections with dents greater than, or equal to, 2           2476/100%   1679/100%
Plus Point Probe examination of tube support intersections with dents greater than, or equal to, 2 2476/100%
volts Plus Point Probe examination of dings greater than, or           404/100%     309/100%
1679/100%
equal to, 4 volts Plus Point Probe examination of all tube support intersections with quantified wear indications by the           311/100%     387/100%
volts Plus Point Probe examination of dings greater than, or 404/100%
bobbin probe Full length of sleeves with the Plus Point Probe                 159/100%     97/100%
309/100%
equal to, 4 volts Plus Point Probe examination of all tube support intersections with quantified wear indications by the 311/100%
387/100%
bobbin probe Full length of sleeves with the Plus Point Probe 159/100%
97/100%
Table 1 Note 1: No indications in a 100% inspection performed in 2004.
Table 1 Note 1: No indications in a 100% inspection performed in 2004.


Inspection of Steam Generator Tubes                                                             Attachment Special Report                                                                                 Page 3 of 13 Results of the Inspection of Tubes Table 2 summarizes the degradation found and number of tubes plugged. Each tube is only counted once in this listing, although it may also have an eddy current indication of a type below the point in the listing where it appears. The Appendices provide detail.
Inspection of Steam Generator Tubes Special Report Attachment Page 3 of 13 Results of the Inspection of Tubes Table 2 summarizes the degradation found and number of tubes plugged. Each tube is only counted once in this listing, although it may also have an eddy current indication of a type below the point in the listing where it appears. The Appendices provide detail.
No degradation was found in:
No degradation was found in:
    " the cold leg tubesheet region
" the cold leg tubesheet region tubing bends dings in tubing freespan A robotic visual inspection of the untubed regions of the top of the tubesheet (i.e., tube bundle periphery and central blowdown lane) was performed on the secondary side of both Steam Generators.
    " tubing bends
* dings in tubing freespan A robotic visual inspection of the untubed regions of the top of the tubesheet (i.e., tube bundle periphery and central blowdown lane) was performed on the secondary side of both Steam Generators.
One previously unretrievable analyzed object was again observed and re-verified unretrievable in the hot leg periphery of Steam Generator 88. Two previously unretrievable analyzed objects were again observed and re-verified unretrievable in the cold leg periphery and in the stay cavity region of Steam Generator 89. All three of these objects have an analysis for acceptability for tube integrity documented in the Corrective Action Process.
One previously unretrievable analyzed object was again observed and re-verified unretrievable in the hot leg periphery of Steam Generator 88. Two previously unretrievable analyzed objects were again observed and re-verified unretrievable in the cold leg periphery and in the stay cavity region of Steam Generator 89. All three of these objects have an analysis for acceptability for tube integrity documented in the Corrective Action Process.
TABLE 2 - Degradation Found and Number of Tubes Plugged: U2C15 Refueling Outage Steam Generator Indication Orientation/Location                      E-088 E-089 Tubes with axially oriented ID (initiated on the inside-diameter of       1       2 the tubing wall) indications at tube support locations Tubes with axially oriented OD (initiated on the outside-diameter       28       47 of the tubing wall) indications at tube support locations Tubes with axially oriented OD indications not associated with a         2         2 tube support (freespan)
TABLE 2 - Degradation Found and Number of Tubes Plugged: U2C15 Refueling Outage Steam Generator E-088 E-089 Indication Orientation/Location Tubes with axially oriented ID (initiated on the inside-diameter of 1
Tubes with circumferentially oriented ID indications near the           33       12 expansion transition at the top of the hot leg tubesheet Tubes with circumferentially oriented OD indications near the             15       22 expansion transition at the top of the hot leg tubesheet Tubes with axially oriented OD indications near the top of the hot       4         6 leg tubesheet Tubes with axially oriented ID indications in the hot leg tubesheet     34       10 region Tubes with circumferentially oriented ID indications in the hot leg       8         6 tubesheet region Tubes with indications of wear at tube support locations                 7       17 Sleeved tubes with an eddy current signal indicative of the onset         1       1 of obstruction (Notes 1 and 2)
2 the tubing wall) indications at tube support locations Tubes with axially oriented OD (initiated on the outside-diameter 28 47 of the tubing wall) indications at tube support locations Tubes with axially oriented OD indications not associated with a 2
Total     133     125
2 tube support (freespan)
Tubes with circumferentially oriented ID indications near the 33 12 expansion transition at the top of the hot leg tubesheet Tubes with circumferentially oriented OD indications near the 15 22 expansion transition at the top of the hot leg tubesheet Tubes with axially oriented OD indications near the top of the hot 4
6 leg tubesheet Tubes with axially oriented ID indications in the hot leg tubesheet 34 10 region Tubes with circumferentially oriented ID indications in the hot leg 8
6 tubesheet region Tubes with indications of wear at tube support locations 7
17 Sleeved tubes with an eddy current signal indicative of the onset 1
1 of obstruction (Notes 1 and 2)
Total 133 125


Inspection of Steam Generator Tubes                                                                     Attachment Special Report                                                                                         Page 4 of 13 Table 2 Note 1: These two sleeves were inspected full length with the rotating plus point probe.
Inspection of Steam Generator Tubes Special Report Attachment Page 4 of 13 Table 2 Note 1: These two sleeves were inspected full length with the rotating plus point probe.
They were not obstructed.
They were not obstructed.
Table 2 Note 2: Overall, the rotating plus point probe inspection results for 100% of the sleeves indicated the effectiveness of previous significant preventive plugging. However, SCE Nuclear Fuel Management continues implementation of a conservative assumption (for accident analysis) that each remaining inservice sleeve may pose the potential for reactor coolant flow blockage, similar to that of a tube that is removed from service by plugging. The previous preventive plugging and the conservative assumption were described in the previous report (Letter from B. Katz (SCE) to Document Control Desk (NRC) dated February 7, 2006;  
Table 2 Note 2: Overall, the rotating plus point probe inspection results for 100% of the sleeves indicated the effectiveness of previous significant preventive plugging. However, SCE Nuclear Fuel Management continues implementation of a conservative assumption (for accident analysis) that each remaining inservice sleeve may pose the potential for reactor coolant flow blockage, similar to that of a tube that is removed from service by plugging. The previous preventive plugging and the conservative assumption were described in the previous report (Letter from B. Katz (SCE) to Document Control Desk (NRC) dated February 7, 2006;  
Line 71: Line 84:
Docket No. 50-361, Special Report: Inservice Inspection of Steam Generator Tubes, Cycle 14, San Onofre Nuclear Generating Station, Unit 2).
Docket No. 50-361, Special Report: Inservice Inspection of Steam Generator Tubes, Cycle 14, San Onofre Nuclear Generating Station, Unit 2).
Examination Techniques Table 3 provides the list of Nondestructive Examination (NDE) techniques utilized for each degradation mechanism.
Examination Techniques Table 3 provides the list of Nondestructive Examination (NDE) techniques utilized for each degradation mechanism.
TABLE 3 - Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism Indication Orientation/Location                                       Probe Type for Detection       Characterization Circumferentially oriented and axially oriented ID indications near or below the expansion transition at the top of the hot leg and cold leg             Plus Point           Plus Point tubesheets Axially oriented OD indications and Circumferentially oriented OD                 Plus Point           Plus Point indications near the top of the hot and cold leg tubesheets Axially oriented OD indications not associated with a tube support                 Bobbin             Plus Point (freespan)
TABLE 3 - Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism Indication Orientation/Location Probe Type for Detection Characterization Circumferentially oriented and axially oriented ID indications near or below the expansion transition at the top of the hot leg and cold leg Plus Point Plus Point tubesheets Axially oriented OD indications and Circumferentially oriented OD Plus Point Plus Point indications near the top of the hot and cold leg tubesheets Axially oriented OD indications not associated with a tube support Bobbin Plus Point (freespan)
Bobbin             Plus Point PlsPin                    Plus Point Axially oriented OD indications at tube support locations                   Plus Point (Note 1)       Plus Point Bobbin             Plus Point PlsP      in              Plus Point Axially oriented ID indications at tube support locations                   Plus Point (Note 1)       Plus Point Indications of wear at tube support locations                                     Bobbin             Plus Point Axially oriented ID indications and Circumferentially oriented ID                 Plus Point           Plus Point indications in Low-Row U-bends Circumferentially oriented ID indications at the flanks of tubing bends           Plus Point           Plus Point Axially oriented OD indications at dings in tubing freespan (dings <5             Bobbin             Plus Point volts)
Bobbin Plus Point Axially oriented OD indications at tube support locations PlsPin Plus Point Plus Point (Note 1)
Axially oriented OD indications at dings in tubing freespan                       Plus Point           Plus Point Axially and Circumferentially oriented ID and OD indications and volumetric indications at sleeve in parent tubing below lower and                 Plus Point           Plus Point above upper joints, and joints Table 3 Note 1: Plus Point technique is used at dents greater than, or equal to, two volts
Plus Point Bobbin Plus Point Axially oriented ID indications at tube support locations PlsP in Plus Point Plus Point (Note 1)
Plus Point Indications of wear at tube support locations Bobbin Plus Point Axially oriented ID indications and Circumferentially oriented ID Plus Point Plus Point indications in Low-Row U-bends Circumferentially oriented ID indications at the flanks of tubing bends Plus Point Plus Point Axially oriented OD indications at dings in tubing freespan (dings <5 Bobbin Plus Point volts)
Axially oriented OD indications at dings in tubing freespan Plus Point Plus Point Axially and Circumferentially oriented ID and OD indications and volumetric indications at sleeve in parent tubing below lower and Plus Point Plus Point above upper joints, and joints Table 3 Note 1: Plus Point technique is used at dents greater than, or equal to, two volts


Inspection of Steam Generator Tubes                                                               Attachment Special Report                                                                                   Page 5 of 13 Condition Monitoring Condition Monitoring demonstrated that performance criteria in Technical Specifications sections 5.5.2.11.b.1 (structural integrity) and 5.5.2.11.b.2 (accident induced leakage) were met during operation prior to this inspection.
Inspection of Steam Generator Tubes Special Report Attachment Page 5 of 13 Condition Monitoring Condition Monitoring demonstrated that performance criteria in Technical Specifications sections 5.5.2.11.b.1 (structural integrity) and 5.5.2.11.b.2 (accident induced leakage) were met during operation prior to this inspection.
In situ pressure testing was not needed for any eddy current indications. All indications were below screening criteria of the Electric Power Research Institute (EPRI) In Situ Pressure Testing Guidelines.
In situ pressure testing was not needed for any eddy current indications. All indications were below screening criteria of the Electric Power Research Institute (EPRI) In Situ Pressure Testing Guidelines.
Table 4 contains all crack-like indications. SONGS Unit 2 Technical Specifications contain alternate repair criteria for a portion of the tube in the tubesheet region. However, all tubes with crack-like indications were removed from service. Voltage is the only size-related measurement for numerous indications in Table 4. This is consistent with industry guidance for tube integrity assessment. Industry guidance provides ranges of voltage measurement values for which voltage is the only needed size-related measurement. Table 4 addresses location, orientation and measured sizes of service-induced indications (except wear of tubing at tube supports). Appendices 3 and 4 address location and measured sizes of service-induced indications of wear of tubing at tube supports.
Table 4 contains all crack-like indications. SONGS Unit 2 Technical Specifications contain alternate repair criteria for a portion of the tube in the tubesheet region. However, all tubes with crack-like indications were removed from service. Voltage is the only size-related measurement for numerous indications in Table 4. This is consistent with industry guidance for tube integrity assessment. Industry guidance provides ranges of voltage measurement values for which voltage is the only needed size-related measurement. Table 4 addresses location, orientation and measured sizes of service-induced indications (except wear of tubing at tube supports). Appendices 3 and 4 address location and measured sizes of service-induced indications of wear of tubing at tube supports.
No tubes were removed (pulled) for destructive testing during this outage.
No tubes were removed (pulled) for destructive testing during this outage.
TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 SG     Row     Col   Elev   Inch   Ind   Origin PP Volts Depth PDA FLDA PP Length               CA 88     6     138   07H   -0.98   SAI     OD     0.15 88     7     55   07C     0.97   SAI     OD     0.32 88     7     137   TSH   -1.95   SCI     ID     0.57     68   N/A                           27 88     7     143   TSH   -4.84   SCI     ID     0.33 88     8     156   TSH   -0.15   SCI     ID     0.57     72   N/A                           27 88     9     51   03H   -0.32   SAI     OD     0.27 88     10     40   TSH   -0.08   SCI     ID     0.23 88     11   147   TSH   -0.07   SCI     ID     0.57     65   N/A                           23 88     12     24   06H   -0.13   SAI     OD     0.27 88     13     47   TSH   -0.02   SCI     ID     0.33 88     13     55   05H     0.64   SAI     OD     0.26 88     14   126   TSH   -0.15   SCI     ID     0.40 88     14   130   TSH   -0.06   SCI     ID     0.45 88     15   141   TSH     -2.8   SCI     ID     0.27 88     16   140   TSH   -8.44   SCI     ID     0.51     36   N/A                           23 88     17     15   TSH   -6.32   SAI     ID     0.55     56           N/A       0.64 88     17     15   TSH   -6.03   SAI     ID     0.55     44           N/A       0.13 88     17     57   01H     0.75   SAI     OD     0.31 88     17     57   06H     0.58   SAI     OD     0.22 88     17     59   TSH   -1.09   SAI     ID     0.42 88     18     34   TSH     0.05   SCI     ID     0.32 88     19   141   TSH   -6.13   SAI     ID     0.50 88     20     120   TSH   -0.19   SCI     ID     0.42
TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 6
138 07H  
-0.98 SAI OD 0.15 88 7
55 07C 0.97 SAI OD 0.32 88 7
137 TSH  
-1.95 SCI ID 0.57 68 N/A 27 88 7
143 TSH  
-4.84 SCI ID 0.33 88 8
156 TSH  
-0.15 SCI ID 0.57 72 N/A 27 88 9
51 03H  
-0.32 SAI OD 0.27 88 10 40 TSH  
-0.08 SCI ID 0.23 88 11 147 TSH  
-0.07 SCI ID 0.57 65 N/A 23 88 12 24 06H  
-0.13 SAI OD 0.27 88 13 47 TSH  
-0.02 SCI ID 0.33 88 13 55 05H 0.64 SAI OD 0.26 88 14 126 TSH  
-0.15 SCI ID 0.40 88 14 130 TSH  
-0.06 SCI ID 0.45 88 15 141 TSH  
-2.8 SCI ID 0.27 88 16 140 TSH  
-8.44 SCI ID 0.51 36 N/A 23 88 17 15 TSH  
-6.32 SAI ID 0.55 56 N/A 0.64 88 17 15 TSH  
-6.03 SAI ID 0.55 44 N/A 0.13 88 17 57 01H 0.75 SAI OD 0.31 88 17 57 06H 0.58 SAI OD 0.22 88 17 59 TSH  
-1.09 SAI ID 0.42 88 18 34 TSH 0.05 SCI ID 0.32 88 19 141 TSH  
-6.13 SAI ID 0.50 88 20 120 TSH  
-0.19 SCI ID 0.42


Inspection of Steam Generator Tubes                                               Attachment Special Report                                                                   Page 6 of 13 TABLE 4- Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 6 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG     Row   Col Elev Inch     Ind Origin PP Volts Depth PDA FLDA PP Length       CA 88     21   31 TSH -14.04     SCI   ID     0.48 88     21   63 07C -0.85     SAI OD     0.35 88     21   113 TSH -2.37     SAI   ID     0.52   54         N/A     0.15 88     21   127 04H 0.77       SAI OD     0.18 88     21   129 TSH -0.09     SCI OD     0.31 88     22   52 03H     -0.7   SAI OD     0.31 88     23   109 TSH -1.15     SAI   ID     0.26 88     23   109 TSH -0.79     SAI   ID     0.51   49         N/A     0.12 88     23   109 TSH -0.57     SAI   ID     0.58   43         N/A     0.15 88     24   64 TSH -0.81     SAI   ID     0.95   36         N/A     0.15 88     24   160 06H -0.06     SAI OD     0.20 88     25   117 TSH -0.16     SCI   ID     0.39 88     25   133 TSH -0.14     SCI   ID     0.70   53   N/A                       27 88     25   133 TSH -0.13     SCI   ID     0.53   61   N/A                       39 88     27   61 TSH -4.41     SAI   ID     0.87   39         N/A     0.15 88     27   61 TSH     -1.2   SAI   ID     0.92   42         N/A     0.24 88     27   159 02H     0.03   SAI OD     0.23 88     27   159 02H     0.79   SAI OD     0.28 88     27   159 03H     0.87   SAI OD     0.49 88     28   120 TSH -6.66     SAI   ID     0.52   51         N/A     0.16 88     30     8 03H     0.85   SAI OD     0.24 88     30   38 TSH -0.08     SCI   ID     0.51   41   N/A                       27 88     30   52 TSH 0.66       SAI OD     0.22 88     31   67 TSH -0.06     SCI   ID     0.61   73   N/A                       27 88     31   69 TSH       0   SAI   ID     0.57   32         N/A     0.12 88     31   107 TSH -1.05     SAI   ID     0.80   43         N/A     0.22 88     31   123 05H     0.66   SAI OD     0.28 88     31   165 05H -0.34     SAI   ID     0.76   66         N/A     0.18 88     31   165 05H     0.39   SAI   ID     0.60   39         N/A     0.12 88     31   165 05H     0.54   SAI   ID     0.39 88     32   112 TSH -2.08     SAI   ID     0.69   46         N/A     0.22 88     32   112 TSH -1.63     SAI   ID     0.81   46         N/A     0.18 88     32   122 TSH -0.88     SAI   ID     0.74   46         N/A     0.12 88     33   37 TSH     -0.1   SCI   ID     0.42 88     34   108 TSH   -0.77   SAI   ID     0.66   51         N/A     0.15 88     35   69 TSH   -1.07   SAI   ID     0.47 88     36   70 TSH   -3.93   SAI   ID     0.70   40         N/A     0.15 88     36   70 TSH   -3.11   SAI   ID     0.51   34         N/A     0.12 88     36   70 TSH   -1.59   SAl   ID     0.75   40         N/A     0.12 88     37   71 TSH   -2.58   SAI   ID     0.66   43         N/A     0.12 88     38   28 01H     0.33   SAI OD     0.23
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 21 31 TSH  
-14.04 SCI ID 0.48 88 21 63 07C  
-0.85 SAI OD 0.35 88 21 113 TSH  
-2.37 SAI ID 0.52 54 N/A 0.15 88 21 127 04H 0.77 SAI OD 0.18 88 21 129 TSH  
-0.09 SCI OD 0.31 88 22 52 03H  
-0.7 SAI OD 0.31 88 23 109 TSH  
-1.15 SAI ID 0.26 88 23 109 TSH  
-0.79 SAI ID 0.51 49 N/A 0.12 88 23 109 TSH  
-0.57 SAI ID 0.58 43 N/A 0.15 88 24 64 TSH  
-0.81 SAI ID 0.95 36 N/A 0.15 88 24 160 06H  
-0.06 SAI OD 0.20 88 25 117 TSH  
-0.16 SCI ID 0.39 88 25 133 TSH  
-0.14 SCI ID 0.70 53 N/A 27 88 25 133 TSH  
-0.13 SCI ID 0.53 61 N/A 39 88 27 61 TSH  
-4.41 SAI ID 0.87 39 N/A 0.15 88 27 61 TSH  
-1.2 SAI ID 0.92 42 N/A 0.24 88 27 159 02H 0.03 SAI OD 0.23 88 27 159 02H 0.79 SAI OD 0.28 88 27 159 03H 0.87 SAI OD 0.49 88 28 120 TSH  
-6.66 SAI ID 0.52 51 N/A 0.16 88 30 8
03H 0.85 SAI OD 0.24 88 30 38 TSH  
-0.08 SCI ID 0.51 41 N/A 27 88 30 52 TSH 0.66 SAI OD 0.22 88 31 67 TSH  
-0.06 SCI ID 0.61 73 N/A 27 88 31 69 TSH 0
SAI ID 0.57 32 N/A 0.12 88 31 107 TSH  
-1.05 SAI ID 0.80 43 N/A 0.22 88 31 123 05H 0.66 SAI OD 0.28 88 31 165 05H  
-0.34 SAI ID 0.76 66 N/A 0.18 88 31 165 05H 0.39 SAI ID 0.60 39 N/A 0.12 88 31 165 05H 0.54 SAI ID 0.39 88 32 112 TSH  
-2.08 SAI ID 0.69 46 N/A 0.22 88 32 112 TSH  
-1.63 SAI ID 0.81 46 N/A 0.18 88 32 122 TSH  
-0.88 SAI ID 0.74 46 N/A 0.12 88 33 37 TSH  
-0.1 SCI ID 0.42 88 34 108 TSH  
-0.77 SAI ID 0.66 51 N/A 0.15 88 35 69 TSH  
-1.07 SAI ID 0.47 88 36 70 TSH  
-3.93 SAI ID 0.70 40 N/A 0.15 88 36 70 TSH  
-3.11 SAI ID 0.51 34 N/A 0.12 88 36 70 TSH  
-1.59 SAl ID 0.75 40 N/A 0.12 88 37 71 TSH  
-2.58 SAI ID 0.66 43 N/A 0.12 88 38 28 01H 0.33 SAI OD 0.23


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                   Page 7 of 13 TABLE 4- Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 7 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG   Row     Col Elev   Inch   Ind Origin PP Volts Depth PDA FLDA PP Length         CA 88     38   28 05H   -0.67   SAI OD     0.44 88     38   110 TSH   -1.44   SAI   ID     0.79   38         N/A     0.15 88     38   110 TSH   -0.65   SAI   ID     0.55   35         N/A     0.18 88     40     58 TSH   -3.72   SAI   ID     0.41 88     40   162 06H     0.25   SAI OD     0.31 88     41     39 TSH   -1.42   SCI   ID     0.71   39   N/A                       31 88     41   69 TSH   -2.14   SAI   ID     0.69   32         N/A     0.12 88     42     14 DBH   -0.81   SAI OD     0.16 88     42     14 DBH   -0.11   SAI OD     0.20 88     42   106 TSH   -1.18   SAI   ID     0.46 88     43     73 TSH     -3.9   SAI   ID     0.65   43         N/A     0.12 88     46   148 01H   -0.16   SAI OD     0.24 88     47   111 TSH   -3.12   SAI   ID     0.35 88     47   111 TSH   -0.87   SAI   ID     0.84   54         N/A     0.33 88     47   143 01H   -0.03   SAI OD     0.15 88     48   124 TSH     -0.1   SCI   ID     0.28 88     48   134 TSH   -0.07   SCI   ID     0.57   50   N/A                       23 88     49   47 08C   -1.17   SAI GD     0.14 88     50   102 TSH   -0.42   SAI   ID     0.40 88     50   106 TSH   -0.07   SAI   ID     0.41 88     50   148 08H     0.81   SAI OD     0.38 88     51     55 TSH     0.03   SCI OD     0.29 88     51     57 TSH     0.06   SCI OD     0.36 88     51   117 TSH     -0.1   SCI   ID     0.69   53   N/A                       27 88     51   155 04H     0.75   SAI OD     0.21 88     52     72 TSH     0.23   SAI OD     0.17 88     52   112 TSH   -3.67   SAI   ID     0.45 88     52   112 TSH   -3.37   SAI   ID     0.67   43         N/A       0.31 88     52   112 TSH   -2.57   SAI   ID     0.51   34         N/A       0.21 88     52   112 TSH   -1.87   SAI   ID     0.79   43         N/A       0.55 88     53     57 TSH     0.15   MCI OD     0.28 88     53   113 TSH   -3.74   SAI   ID     0.43 88     53   113 TSH   -5.31   SAI   ID     0.68   41         N/A       0.18 88     53   113 TSH   -1.74   SAI   ID     0.74   41         N/A       0.18 88     54     38 TSH   -0.02   SCI   ID     0.49 88     54     60 TSH     0.15   SAI OD     0.17 88     54     72 TSH     0.06   SCI OD     0.20 88     56   126 TSH   -0.17   SCI   ID     0.39 88     56   154 TSH   -7.34   SAI   ID     0.53   38         N/A       0.12 88     57     73 TSH     0.09   SCI OD     0.12
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 38 28 05H  
-0.67 SAI OD 0.44 88 38 110 TSH  
-1.44 SAI ID 0.79 38 N/A 0.15 88 38 110 TSH  
-0.65 SAI ID 0.55 35 N/A 0.18 88 40 58 TSH  
-3.72 SAI ID 0.41 88 40 162 06H 0.25 SAI OD 0.31 88 41 39 TSH  
-1.42 SCI ID 0.71 39 N/A 31 88 41 69 TSH  
-2.14 SAI ID 0.69 32 N/A 0.12 88 42 14 DBH  
-0.81 SAI OD 0.16 88 42 14 DBH  
-0.11 SAI OD 0.20 88 42 106 TSH  
-1.18 SAI ID 0.46 88 43 73 TSH  
-3.9 SAI ID 0.65 43 N/A 0.12 88 46 148 01H  
-0.16 SAI OD 0.24 88 47 111 TSH  
-3.12 SAI ID 0.35 88 47 111 TSH  
-0.87 SAI ID 0.84 54 N/A 0.33 88 47 143 01H  
-0.03 SAI OD 0.15 88 48 124 TSH  
-0.1 SCI ID 0.28 88 48 134 TSH  
-0.07 SCI ID 0.57 50 N/A 23 88 49 47 08C  
-1.17 SAI GD 0.14 88 50 102 TSH  
-0.42 SAI ID 0.40 88 50 106 TSH  
-0.07 SAI ID 0.41 88 50 148 08H 0.81 SAI OD 0.38 88 51 55 TSH 0.03 SCI OD 0.29 88 51 57 TSH 0.06 SCI OD 0.36 88 51 117 TSH  
-0.1 SCI ID 0.69 53 N/A 27 88 51 155 04H 0.75 SAI OD 0.21 88 52 72 TSH 0.23 SAI OD 0.17 88 52 112 TSH  
-3.67 SAI ID 0.45 88 52 112 TSH  
-3.37 SAI ID 0.67 43 N/A 0.31 88 52 112 TSH  
-2.57 SAI ID 0.51 34 N/A 0.21 88 52 112 TSH  
-1.87 SAI ID 0.79 43 N/A 0.55 88 53 57 TSH 0.15 MCI OD 0.28 88 53 113 TSH  
-3.74 SAI ID 0.43 88 53 113 TSH  
-5.31 SAI ID 0.68 41 N/A 0.18 88 53 113 TSH  
-1.74 SAI ID 0.74 41 N/A 0.18 88 54 38 TSH  
-0.02 SCI ID 0.49 88 54 60 TSH 0.15 SAI OD 0.17 88 54 72 TSH 0.06 SCI OD 0.20 88 56 126 TSH  
-0.17 SCI ID 0.39 88 56 154 TSH  
-7.34 SAI ID 0.53 38 N/A 0.12 88 57 73 TSH 0.09 SCI OD 0.12


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                     Page 8 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 8 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG   Row     Col Elev   Inch   Ind Origin PP Volts Depth PDA FLDA PP Length         CA 88     57   105 TSH   -2.35   SAI   ID     0.41 88     57   161 06H   -0.41   SAI OD     0.41   42           N/A     0.61 88     58   70 TSH   -2.27   SAI   ID     0.65   54           N/A     0.12 88     59   83 TSH     -1.4   SAI   ID     0.56   58           N/A     0.14 88     59   83 TSH   -0.87   SAI   ID     0.30   47           N/A     0.12 88   60     86 VC3     0.84   SAI OD     0.23 88   60     106 TSH       0   SCI   ID     0.31 88   62     80 TSH     0.03   SCI OD     0.22 88   62     114 TSH   -2.04   SAI   ID     0.58   49           N/A     0.12 88   64     120 TSH   -0.03   SCI   ID     0.47 88   65     87 TSH   0.06   SCI OD     0.14 88   65     111 TSH   -1.11   SAI   ID     0.75   46           N/A     0.17 88   65     111 TSH   -0.15   SCI   ID     0.41 88   67     111 TSH     0.16   SCI OD     0.16 88   68     112 TSH   -9.88   SCI   ID     0.30 88   68     112 TSH   -6.12   MCI   ID     0.55   72     N/A                       74 88   69     119 TSH   -0.03   SCI   ID     0.51   66     N/A                       39 88     69   119 TSH   -0.02   SCI   ID     0.37   56     N/A                       19 88   70     86 TSH   -2.15   SAI   ID     0.50 88     70   86 TSH   -1.84   SAI   ID     0.46 88     70   104 TSH   0.17   SAI OD     0.29 88     72   100 TSH   0.05   SCI OD     0.33 88     75   95 TSH   -0.19   SCI   ID     0.63   74     N/A                       62 88     75   99 TSH     0.08   SCI OD     0.24 88     76     18 06H     0.62   SAI OD     0.22 88     77   85 TSH   -1.92   SAI   ID     0.68   44           N/A     0.16 88     78   74 TSH   -0.06   SCI   ID     0.32 88     78   96 TSH     0.11   SCI OD     0.20 88     78   98 TSH     -0.1   SCI   ID     0.38 88     78   102 TSH       0   SCI   ID     0.53   78     N/A                       27 88     78   120 TSH     -6   SCI   ID     0.39 88     79   81 TSH   -0.05   SCI   ID     0.17 88     79   97 TSH     0.03   SCI OD     0.37 88     80   84 TSH   -0.08   SCI   ID     0.24 88     81   93 TSH     -2.6   SAI   ID     0.61   44           N/A     0.21 88     83   49 02H     2.02   SAI 0D     0.32 88     83   87 TSH   -0.12   SCI   ID     0.45 88     88   60 01H   2.27   SAI OD     0.20 88     90   42 08H     0.75   SAI OD     0.26 88     90   42 VC2     0.12   SAI OD     0.24
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 57 105 TSH  
-2.35 SAI ID 0.41 88 57 161 06H  
-0.41 SAI OD 0.41 42 N/A 0.61 88 58 70 TSH  
-2.27 SAI ID 0.65 54 N/A 0.12 88 59 83 TSH  
-1.4 SAI ID 0.56 58 N/A 0.14 88 59 83 TSH  
-0.87 SAI ID 0.30 47 N/A 0.12 88 60 86 VC3 0.84 SAI OD 0.23 88 60 106 TSH 0
SCI ID 0.31 88 62 80 TSH 0.03 SCI OD 0.22 88 62 114 TSH  
-2.04 SAI ID 0.58 49 N/A 0.12 88 64 120 TSH  
-0.03 SCI ID 0.47 88 65 87 TSH 0.06 SCI OD 0.14 88 65 111 TSH  
-1.11 SAI ID 0.75 46 N/A 0.17 88 65 111 TSH  
-0.15 SCI ID 0.41 88 67 111 TSH 0.16 SCI OD 0.16 88 68 112 TSH  
-9.88 SCI ID 0.30 88 68 112 TSH  
-6.12 MCI ID 0.55 72 N/A 74 88 69 119 TSH  
-0.03 SCI ID 0.51 66 N/A 39 88 69 119 TSH  
-0.02 SCI ID 0.37 56 N/A 19 88 70 86 TSH  
-2.15 SAI ID 0.50 88 70 86 TSH  
-1.84 SAI ID 0.46 88 70 104 TSH 0.17 SAI OD 0.29 88 72 100 TSH 0.05 SCI OD 0.33 88 75 95 TSH  
-0.19 SCI ID 0.63 74 N/A 62 88 75 99 TSH 0.08 SCI OD 0.24 88 76 18 06H 0.62 SAI OD 0.22 88 77 85 TSH  
-1.92 SAI ID 0.68 44 N/A 0.16 88 78 74 TSH  
-0.06 SCI ID 0.32 88 78 96 TSH 0.11 SCI OD 0.20 88 78 98 TSH  
-0.1 SCI ID 0.38 88 78 102 TSH 0
SCI ID 0.53 78 N/A 27 88 78 120 TSH  
-6 SCI ID 0.39 88 79 81 TSH  
-0.05 SCI ID 0.17 88 79 97 TSH 0.03 SCI OD 0.37 88 80 84 TSH  
-0.08 SCI ID 0.24 88 81 93 TSH  
-2.6 SAI ID 0.61 44 N/A 0.21 88 83 49 02H 2.02 SAI 0D 0.32 88 83 87 TSH  
-0.12 SCI ID 0.45 88 88 60 01H 2.27 SAI OD 0.20 88 90 42 08H 0.75 SAI OD 0.26 88 90 42 VC2 0.12 SAI OD 0.24


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                   Page 9 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 9 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG   Row     Col Elev   Inch   Ind Origin PP Volts Depth PDA FLDA PP Length         CA 88     90     78 TSH   -0.11 SCI   ID     0.27 88     94   48 01H     0.21   SAI OD     0.24 88     95     71 TSH   -0.08   SCI   ID     0.30 88     98     94 TSH       0   SCI OD     0.22 88   100   102 TSH   -0.07   SCI   ID     0.19 88   100   118 TSH       0   SCI   ID     0.39 88   107     97 TSH     0.03   SCI OD     0.28 88   111     67 02H     1.06   SAI OD     0.46 88   143   109 03H   -0.85   SAI OD     0.46 89     2   122 01H     0.74   SAI OD     0.30 89     3   127 07C     0.01   SAI OD     0.41 89     5   119 07H     -0.5   SAI OD     0.53     50         N/A     0.32 89     5   119 07C     0.61   SAI OD     0.33 89     5   119 07H     -0.3   SAI OD     0.33 89     6     58 TSH   -6.31   SCI   ID     0.33 89     8     36 05H   -0.71   SAI OD     0.35 89     8   122 07H   -0.62   SAI OD     0.27 89     9     65 07H     0.73   SAI OD     0.32 89     9   117 05H     0.91   SAI OD     0.26 89     10     44 05H   -0.83   SAI OD     0.31 89     10     44 05H     0.54   SAI OD     0.23 89     11     19 04H   -0.19   SAI OD     0.23 89     11     19 06H     0.22   SAI OD     0.30 89     11     55 05H     0.94   SAI OD     0.37 89     11     65 01H     0.54   SAI OD     0.30 89     11   119 04H   -0.25   SAI OD     0.31 89     11   121 TSH   -10.71   SCI   ID     0.50 89     11   131 TSH   -13.59   SCI   ID     0.72     38   N/A                       28 89     12   114 06H   -0.16   SAI OD     0.40 89     12   128 01H     0.58   SAI OD     0.22 89     12   128 04H     0.5   SAI OD     0.34 89     14     18 05H     0.88   SAI OD     0.17 89     14     58 04H     1.07   SAI OD     0.41 89     15   131 TSH     -0.1   SCI   ID     0.43 89     15   141 TSH   -0.08   SCI   ID     0.54     47   N/A                       27 89     16     56 06H   -1.39   SAI OD     0.12 89     16     60 TSH   -0.09   SCI   ID     0.39 89     17     49 TSH     0.08   SCI OD     0.13 89     18     26 06H   -0.15   SAI OD     0.20
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 90 78 TSH  
-0.11 SCI ID 0.27 88 94 48 01H 0.21 SAI OD 0.24 88 95 71 TSH  
-0.08 SCI ID 0.30 88 98 94 TSH 0
SCI OD 0.22 88 100 102 TSH  
-0.07 SCI ID 0.19 88 100 118 TSH 0
SCI ID 0.39 88 107 97 TSH 0.03 SCI OD 0.28 88 111 67 02H 1.06 SAI OD 0.46 88 143 109 03H  
-0.85 SAI OD 0.46 89 2
122 01H 0.74 SAI OD 0.30 89 3
127 07C 0.01 SAI OD 0.41 89 5
119 07H  
-0.5 SAI OD 0.53 50 N/A 0.32 89 5
119 07C 0.61 SAI OD 0.33 89 5
119 07H  
-0.3 SAI OD 0.33 89 6
58 TSH  
-6.31 SCI ID 0.33 89 8
36 05H  
-0.71 SAI OD 0.35 89 8
122 07H  
-0.62 SAI OD 0.27 89 9
65 07H 0.73 SAI OD 0.32 89 9
117 05H 0.91 SAI OD 0.26 89 10 44 05H  
-0.83 SAI OD 0.31 89 10 44 05H 0.54 SAI OD 0.23 89 11 19 04H  
-0.19 SAI OD 0.23 89 11 19 06H 0.22 SAI OD 0.30 89 11 55 05H 0.94 SAI OD 0.37 89 11 65 01H 0.54 SAI OD 0.30 89 11 119 04H  
-0.25 SAI OD 0.31 89 11 121 TSH  
-10.71 SCI ID 0.50 89 11 131 TSH  
-13.59 SCI ID 0.72 38 N/A 28 89 12 114 06H  
-0.16 SAI OD 0.40 89 12 128 01H 0.58 SAI OD 0.22 89 12 128 04H 0.5 SAI OD 0.34 89 14 18 05H 0.88 SAI OD 0.17 89 14 58 04H 1.07 SAI OD 0.41 89 15 131 TSH  
-0.1 SCI ID 0.43 89 15 141 TSH  
-0.08 SCI ID 0.54 47 N/A 27 89 16 56 06H  
-1.39 SAI OD 0.12 89 16 60 TSH  
-0.09 SCI ID 0.39 89 17 49 TSH 0.08 SCI OD 0.13 89 18 26 06H  
-0.15 SAI OD 0.20


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                   Page 10 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 10 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG   Row     Col Elev   Inch   Ind Origin PP Volts Depth PDA FLDA PP Length         CA 89     18     34 TSH   -5.71   SAI   ID     0.29 89     18     34 TSH   -5.26   SAI   ID     0.48   46           N/A     0.18 89     20   120 04H   0.69   SAI OD     0.49   45           N/A       0.7 89     20   120 04H   -0.26   SAI OD     0.42 89     23   137 TSH   -0.14   SCI   ID     0.32 89     24     50 TSH   0.12   SCI OD     0.23 89     24   130 TSH   0.08   SCI OD     0.19 89     25     49 TSH   0.09   SCI OD     0.16 89     25     51 07C     -0.6   SAI OD     0.32 89     25   149 06H   -0.38   SAI OD     0.26 89     28     54 TSH   0.35   SAI OD     0.37 89     28   122 TSH   0.12   MCI   OD     0.19 89     29     47 07H   0.61   SAI OD     0.30 89     29     59 TSH   -3.59   SAI   ID     0.32 89     30   134 TSH   -6.96   SCI   ID     0.47 89     32     48 TSH   -0.09   SCI   ID     0.45 89     33     67 04H     0.5   SAI OD     0.26 89     33     67 TSH   0.47   SAI OD     0.17 89     33     67 TSH   0.62   SAI OD     0.21 89     34   112 04H   -0.34   SAI OD     0.28 89     35     49 TSH   0.27   SAI OD     0.14 89     35   111 04H   -0.29   SAI OD     0.21 89     35   111 TSH   -0.98   SAI   ID     0.72     44         N/A     0.17 89     36   128 TSH   0.05   MCI   OD     0.34 89     38     8 06H     0.7   SAI OD     0.23 89     39     45 TSH   0.04   MCI   OD     0.18 89     39   131 TSH   -8.54   SAI   ID     0.47     38         N/A     0.15 89     39   131 TSH     -7.5   SAI   ID     0.60     40         N/A     0.12 89     39   133 TSH   -7.28   SAI   ID     0.73     60         N/A     0.17 89     39   133 TSH     0.03   SCI OD     0.24 89     40     46 TSH     0.05   SCI OD     0.25 89     40     60 TSH     0.31   SAI OD     0.33 89     40   136 TSH   -8.81   SCI   ID     0.51     53   N/A                       27 89     41   131 TSH   -0.16   SCI   ID     0.57     53   N/A                       50 89     42     38 TSH   -0.12   SCI   ID     0.91     71   N/A                       31 89     45     63 TSH     0.19   SAI OD     0.26 89     45     63 TSH   -3.16   SAI   ID     0.76     57         N/A     0.16 89     45     63 TSH   -2.39   SAI   ID     0.53     60         N/A     0.16 89     46     48 TSH     0.14   SCI OD     0.13 89     46   126 03H   -0.29   SAI OD     0.41
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 18 34 TSH  
-5.71 SAI ID 0.29 89 18 34 TSH  
-5.26 SAI ID 0.48 46 N/A 0.18 89 20 120 04H 0.69 SAI OD 0.49 45 N/A 0.7 89 20 120 04H  
-0.26 SAI OD 0.42 89 23 137 TSH  
-0.14 SCI ID 0.32 89 24 50 TSH 0.12 SCI OD 0.23 89 24 130 TSH 0.08 SCI OD 0.19 89 25 49 TSH 0.09 SCI OD 0.16 89 25 51 07C  
-0.6 SAI OD 0.32 89 25 149 06H  
-0.38 SAI OD 0.26 89 28 54 TSH 0.35 SAI OD 0.37 89 28 122 TSH 0.12 MCI OD 0.19 89 29 47 07H 0.61 SAI OD 0.30 89 29 59 TSH  
-3.59 SAI ID 0.32 89 30 134 TSH  
-6.96 SCI ID 0.47 89 32 48 TSH  
-0.09 SCI ID 0.45 89 33 67 04H 0.5 SAI OD 0.26 89 33 67 TSH 0.47 SAI OD 0.17 89 33 67 TSH 0.62 SAI OD 0.21 89 34 112 04H  
-0.34 SAI OD 0.28 89 35 49 TSH 0.27 SAI OD 0.14 89 35 111 04H  
-0.29 SAI OD 0.21 89 35 111 TSH  
-0.98 SAI ID 0.72 44 N/A 0.17 89 36 128 TSH 0.05 MCI OD 0.34 89 38 8
06H 0.7 SAI OD 0.23 89 39 45 TSH 0.04 MCI OD 0.18 89 39 131 TSH  
-8.54 SAI ID 0.47 38 N/A 0.15 89 39 131 TSH  
-7.5 SAI ID 0.60 40 N/A 0.12 89 39 133 TSH  
-7.28 SAI ID 0.73 60 N/A 0.17 89 39 133 TSH 0.03 SCI OD 0.24 89 40 46 TSH 0.05 SCI OD 0.25 89 40 60 TSH 0.31 SAI OD 0.33 89 40 136 TSH  
-8.81 SCI ID 0.51 53 N/A 27 89 41 131 TSH  
-0.16 SCI ID 0.57 53 N/A 50 89 42 38 TSH  
-0.12 SCI ID 0.91 71 N/A 31 89 45 63 TSH 0.19 SAI OD 0.26 89 45 63 TSH  
-3.16 SAI ID 0.76 57 N/A 0.16 89 45 63 TSH  
-2.39 SAI ID 0.53 60 N/A 0.16 89 46 48 TSH 0.14 SCI OD 0.13 89 46 126 03H  
-0.29 SAI OD 0.41


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                   Page 11 of 13 TABLE 4- Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 11 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG   Row     Col Elev   Inch   Ind Origin PP Volts Depth PDA FLDA PP Length         CA 89     46   134 06H     0.16   SAI OD     0.47     46       30.43     0.87 89     48     12 04H     0.61   SAI OD     0.35 89     48     52 TSH     0.12   SCI OD     0.15 89     48     64 TSH   -1.43   SAI   ID     0.37 89     48     64 TSH   -2.18   SAI   ID     0.43     40         N/A     0.13 89     48   130 TSH   -0.13   SCI   ID     0.36 89     49     51 TSH     0.07 MCI   OD     0.15 89     49     53 TSH     0.09   SCI OD     0.17 89     49     57 08H     1.54   SAI OD     0.31 89     50   106 TSH     0.15   SCI OD     0.27 89     52   120 TSH   -0.13   SCI   ID     0.62     63   N/A                       28 89     54     52 TSH   -5.76   SCI   ID     0.44 89     54   102 01H   13.43   SAI OD     0.27 89     55     45 TSH   -0.16   SCI   ID     0.36 89     57     77 TSH     0.07 MCI   OD     0.25 89     57     97 TSH   -4.39   SAI   ID     0.50     46         N/A       0.13 89     58     54 TSH   -6.25   SAI   ID     0.34 89     59     53 TSH   -0.17   SCI   ID     0.25 89     59     89 06C   -0.69   SAI OD     0.30 89     59     89 VH3     0.08   SAI OD     0.31 89     62     74 TSH     1.36   SAI OD     0.22 89     62     92 TSH     0.13   SCI OD     0.20     94   N/A                       51 89     64     76 05H     0.67   SAI OD     0.28 89     64     80 TSH   -2.87   SAI   ID     0.35 89     64     84 TSH     0.09   SCI OD     0.19 89     65     37 VSM   -0.93   SAI OD     0.21 89     70     68 TSH     0.06   SCI OD     0.24 89     70     92 TSH   -2.27   SAI   ID     0.29 89     71     57 08H     0.52   SAI OD     0.15 89     71     67 TSH     0.14   SCI OD     0.46 89     75     53 TSH   -0.03   SCI OD     0.12 89     79     53 TSH   -0.02   SCI   ID     0.57     53   N/A                       27 89     79     89 TSH       1   SAI OD     0.17 89     79     99 TSH       0   SCI OD     0.33 89     83     73 03H   -0.11   SAI OD     0.29 89     85     81 TSH     0.19   SCI OD     0.31 89     87     31 05H     0.33   SAI   ID     0.82     51         N/A       0.15 89     87     47 03H   -0.21   SAI OD     0.18 89     89     93 TSH     -13   SAI   ID     0.48     46         N/A       0.12 89     91     85 03H     0.2   SAI OD     0.33   1
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 46 134 06H 0.16 SAI OD 0.47 46 30.43 0.87 89 48 12 04H 0.61 SAI OD 0.35 89 48 52 TSH 0.12 SCI OD 0.15 89 48 64 TSH  
-1.43 SAI ID 0.37 89 48 64 TSH  
-2.18 SAI ID 0.43 40 N/A 0.13 89 48 130 TSH  
-0.13 SCI ID 0.36 89 49 51 TSH 0.07 MCI OD 0.15 89 49 53 TSH 0.09 SCI OD 0.17 89 49 57 08H 1.54 SAI OD 0.31 89 50 106 TSH 0.15 SCI OD 0.27 89 52 120 TSH  
-0.13 SCI ID 0.62 63 N/A 28 89 54 52 TSH  
-5.76 SCI ID 0.44 89 54 102 01H 13.43 SAI OD 0.27 89 55 45 TSH  
-0.16 SCI ID 0.36 89 57 77 TSH 0.07 MCI OD 0.25 89 57 97 TSH  
-4.39 SAI ID 0.50 46 N/A 0.13 89 58 54 TSH  
-6.25 SAI ID 0.34 89 59 53 TSH  
-0.17 SCI ID 0.25 89 59 89 06C  
-0.69 SAI OD 0.30 89 59 89 VH3 0.08 SAI OD 0.31 89 62 74 TSH 1.36 SAI OD 0.22 89 62 92 TSH 0.13 SCI OD 0.20 94 N/A 51 89 64 76 05H 0.67 SAI OD 0.28 89 64 80 TSH  
-2.87 SAI ID 0.35 89 64 84 TSH 0.09 SCI OD 0.19 89 65 37 VSM  
-0.93 SAI OD 0.21 89 70 68 TSH 0.06 SCI OD 0.24 89 70 92 TSH  
-2.27 SAI ID 0.29 89 71 57 08H 0.52 SAI OD 0.15 89 71 67 TSH 0.14 SCI OD 0.46 89 75 53 TSH  
-0.03 SCI OD 0.12 89 79 53 TSH  
-0.02 SCI ID 0.57 53 N/A 27 89 79 89 TSH 1
SAI OD 0.17 89 79 99 TSH 0
SCI OD 0.33 89 83 73 03H  
-0.11 SAI OD 0.29 89 85 81 TSH 0.19 SCI OD 0.31 89 87 31 05H 0.33 SAI ID 0.82 51 N/A 0.15 89 87 47 03H  
-0.21 SAI OD 0.18 89 89 93 TSH  
-13 SAI ID 0.48 46 N/A 0.12 89 91 85 03H 0.2 SAI OD 0.33 1


Inspection of Steam Generator Tubes                                                 Attachment Special Report                                                                   Page 12 of 13 TABLE 4- Measured Sizes of Service-Induced Indications: U2C15 (continued)
Inspection of Steam Generator Tubes Special Report Attachment Page 12 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)
SG     Row   Col   Elev Inch       Ind   Origin PP Volts Depth PDA FLDA PP Length   CA 89     93   113   02H       0.84 SAI     OD         0.35 89     98     62   TSH -13.92     SAI       ID       1.26   55   N/A   0.18 89     98     82   01H -0.44       SAI     OD         0.31 89     106   126   02H       0.24 MAI     OD         0.44 89     108   52   06H 0.67       SAI       ID       1.22   49   N/A   0.15 89     108   126   02H 0.66       SAI     OD         0.33 89     110   122   02H 0.82       SAI     OD         0.30 89     112   134   02H       0.5 SAI     OD         0.54   51   N/A   0.74 89     118   62   01H 0.95       SAI     OD         0.41 89     118   62   04H     0.95 SAI     OD         0.25 89     118   124   02H     0.43 SAI     OD         0.23 89     122   110   05H     -0.3 SAI     OD         0.23 89     128   60   04H     0.75 SAI     OD         0.42 89     130   82   01H     -0.27 SAI     OD         0.67   55   N/A   0.61 Table 4 Notes:
SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 93 113 02H 0.84 SAI OD 0.35 89 98 62 TSH  
-13.92 SAI ID 1.26 55 N/A 0.18 89 98 82 01H  
-0.44 SAI OD 0.31 89 106 126 02H 0.24 MAI OD 0.44 89 108 52 06H 0.67 SAI ID 1.22 49 N/A 0.15 89 108 126 02H 0.66 SAI OD 0.33 89 110 122 02H 0.82 SAI OD 0.30 89 112 134 02H 0.5 SAI OD 0.54 51 N/A 0.74 89 118 62 01H 0.95 SAI OD 0.41 89 118 62 04H 0.95 SAI OD 0.25 89 118 124 02H 0.43 SAI OD 0.23 89 122 110 05H  
-0.3 SAI OD 0.23 89 128 60 04H 0.75 SAI OD 0.42 89 130 82 01H  
-0.27 SAI OD 0.67 55 N/A 0.61 Table 4 Notes:
SG 88 = SG E-088 SG 89 = SG E-089 PP = Plus Point Depth = Percent of Tube Wall Thickness PDA = Percent Degraded Area FLDA = Flaw-Length Degraded Area PP Length (units of measure are inches)
SG 88 = SG E-088 SG 89 = SG E-089 PP = Plus Point Depth = Percent of Tube Wall Thickness PDA = Percent Degraded Area FLDA = Flaw-Length Degraded Area PP Length (units of measure are inches)
CA = Crack Angle (degrees)
CA = Crack Angle (degrees)
Appendices 1 and 2 provide definitions for other terms
Appendices 1 and 2 provide definitions for other terms


Inspection of Steam Generator Tubes                                                             Attachment Special Report                                                                               Page 13 of 13 Repair Methods, Number of Tubes Repaired and Effective Plugging Percentage All tube plugging was performed using the design, materials, and installation methods of AREVA. A "roll" method was used for all tube plugs. Eighty-eight (88) tubes were "stabilized" in the vicinity of the top of the tubesheet using the design, materials, and installation methods of AREVA. Sleeving was not used for tube repair for the Cycle 15 outage. The design number of tubes in each SG is 9350 tubes and the sleeve-to-plug equivalency ratio is thirty-eight (38) sleeves per plug.
Inspection of Steam Generator Tubes Special Report Attachment Page 13 of 13 Repair Methods, Number of Tubes Repaired and Effective Plugging Percentage All tube plugging was performed using the design, materials, and installation methods of AREVA. A "roll" method was used for all tube plugs. Eighty-eight (88) tubes were "stabilized" in the vicinity of the top of the tubesheet using the design, materials, and installation methods of AREVA. Sleeving was not used for tube repair for the Cycle 15 outage. The design number of tubes in each SG is 9350 tubes and the sleeve-to-plug equivalency ratio is thirty-eight (38) sleeves per plug.
TABLE 5 - Number of Tubes Plugged or Repaired and Effective Plugging Percentage
TABLE 5 - Number of Tubes Plugged or Repaired and Effective Plugging Percentage
                              # Tubes           # Tubes           # Sleeves         Effective SG             Plugged in         Plugged To       Remaining in         Plugging 2C15               Date             Service         Percentage 88                 133               1390               155               15.0%
# Tubes  
89                 125               1251               91               13.5%
# Tubes  
Description of Appendices Appendix 1 - Steam Generator Reference Information Appendix 2 -   Legend for Appendices 3 and 4 Appendix 3 - Tube Inspection Summary, Steam Generator E-088 Appendix 4 - Tube Inspection Summary, Steam Generator E-089
# Sleeves Effective SG Plugged in Plugged To Remaining in Plugging 2C15 Date Service Percentage 88 133 1390 155 15.0%
89 125 1251 91 13.5%
Description of Appendices Appendix 1 -
Steam Generator Reference Information Appendix 2 -
Legend for Appendices 3 and 4 Appendix 3 -
Tube Inspection Summary, Steam Generator E-088 Appendix 4 -
Tube Inspection Summary, Steam Generator E-089


Inspection of Steam Generator Tubes                           Appendix 1 Special Report                                                Page 1 of 4 Appendix 1 Steam Generator Reference Information
Inspection of Steam Generator Tubes Special Report Appendix 1 Page 1 of 4 Appendix 1 Steam Generator Reference Information


Inspection of Steam Generator Tubes                                             Appendix 1 Special Report                                                                   Page 2 of 4 Steam Generator CE Model 3410 Tube Support Drawing 1S" 16' 16' 16" 16' 16' 10H-                                     10OC
Inspection of Steam Generator Tubes Appendix 1 Special Report Page 2 of 4 Steam Generator CE Model 3410 Tube Support Drawing 1S" 16' 16' 16" 16' 16' 10H-10OC 30.75' 09H 09C 30.75' 08H 08C 30.7V 07H.
                                                    $                    30.75' 09H                                   09C 30.75' 08H                               08C     30.7V 07H .                             07C 38" 06H                               06C 34" 05H                               05C a5" 04H                               04C 38" 03H                               03C 36" 02H                               02C 35.
07C 38" 06H 06C 34" 05H 05C a5" 04H 04C 38" 03H 03C 36" 02H 02C 35.
O1H J27.2S" 0lC TSC TSH 23' TEH                   TT-         TEC
O1H 0lC
________ J27.2S" TSH TSC 23' TEH TT-TEC


Inspection of Steam Generator Tubes                                                 Appendix 1 Special Report                                                                      Page 3 of 4 STEAM GENERATOR TUBE SUPPORT INTERSECTIONS ABOVE THE 7 TH (FULL) EGGCRATE SUPPORT SUPPORT INTERSECTIONS ROW                                               STRUCTURES 122-147   08H   09H     10H   DBH     VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C   09C   08C 120-121*     08H   09H     10H   DBH     VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C   09C   08C 115-119     08H   09H           DBH     VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC       09C   08C 86-114     08H   09H           DBH         VH2 VH3 VSM VC3 VC2     DBC       09C   08C 84-85*     08H   09H           DBH         VH2 VH3 VSM VC3 VC2     DBC       09C   08C 83       08H                   DBH         VH2 VH3 VSM VC3 VC2     DBC             08C 51-82     08H                   DBH             VH3 VSM VC3         DBC             08C 49-50*     08H                   DBH                 VSM             DBC             08C 19-48                           DBH                 VSM             DBC 1-18                           DBH                                 DBC
Inspection of Steam Generator Tubes Special Report Appendix 1 Page 3 of 4 STEAM GENERATOR TUBE SUPPORT INTERSECTIONS ABOVE THE 7 TH (FULL) EGGCRATE SUPPORT SUPPORT INTERSECTIONS ROW STRUCTURES 122-147 08H 09H 10H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 120-121*
08H 09H 10H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 115-119 08H 09H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 09C 08C 86-114 08H 09H DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 84-85*
08H 09H DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 83 08H DBH VH2 VH3 VSM VC3 VC2 DBC 08C 51-82 08H DBH VH3 VSM VC3 DBC 08C 49-50*
08H DBH VSM DBC 08C 19-48 DBH VSM DBC 1-18 DBH DBC
* Indicates those rows adjacent to scallop bars
* Indicates those rows adjacent to scallop bars


Inspection of Steam Generator Tubes                                                                                                                                                                                                                                                                                     Appendix 1 Special Report                                                                                                                                                                                                                                                                                                          Page 4 of 4 SOUTHERN CALIFORNIA EDISON, SAN ONOFRE CE MODEL 3410 STEAM GENERATOR 10               z0               V)               40                 50                 rO               70               so               so             10                 110                 120             130               140                 150             160               170 00 00 600006Q0 140                                                                                                                                                                            00                                                                                                                                           149 0o 00      0 0       0 0 o'o                  009
Inspection of Steam Generator Tubes Special Report Appendix 1 Page 4 of 4 SOUTHERN CALIFORNIA EDISON, SAN ONOFRE CE MODEL 3410 STEAM GENERATOR 10 z0 V) 40 50 rO 70 so so 10 110 120 130 140 150 160 170 140 130 120 100 s0 80 70 149 00 0
:'001001 0000 0 010 i'90      0      0-0              0 0 0                                                              01 Aq                          200 0-                                                     G 0        1 MMM,           59?m&#xfd;-
0o 00 00 600006Q0 00 0000 0 010 0-0 0 0 0
130                                                                                                                                                                                                                                                                                                                  -      130 0         a     06co       00&#xfd;'&#xfd;a 430 P'6 &Q p                       0 0     0&#xfd;0&#xfd;0&#xfd;0 080&#xfd;080&#xfd;0             0     00     00     10, 6 U616 16, 90 0                                                                               go                       go0 jooso"v 0 9 0 0-0 a 6-               0                         ' ' ' 20                      00106100'0'00&#xfd; 200" 00 0 o.
0 0 o'o 009 i'90 01
69                                    ?00 50040roo 10-0220'0&#xfd;       0                      9             -00 M&#xfd; .5'0iP5'.Q'0 &#xfd;26262528 62526262o041,                    -1                                           a, 0-          OX 120                                                                                        :'-6'-26-206-'26     66                              11600600                                                                   696 0     00              .'4'. 0 0 6-,6         0.-.00      10                                     00 9OR                '01 000  010 0 I 00 00 000                                                                                             0    0            0                           0 "I                       I    solo0,00 B 0                          000 CR, 9890&#xfd;         0("
:'001001 0
                                                                                                                                                      &#xfd;-'00:'52'0;'o         2-'0200     000     MQ            -zo v                           ERR-0, o.'-',o- `-N'.     2n'&#xfd; Q&#xfd;         on.                                                                                     -      Ito 060606060 060606060 0 Q-                                                                              &#xfd;0         01                                                  0 "Q  Q-?Ugo        6006000 U                              6 go 01 10            10                                                              0       0 09, 3g"      0     0 000l'o .0,0,0"0,   0.,.Qo,.,
0 G 0 1
: 0.      01 0&#xfd;0'00               00    0   C                                                         00000     0000009,0,00   8`1     0   r"00 01OX0                                          o     100&#xfd;0 00       0        10    0      00
0-MMM, 59?m&#xfd;-
                                                                                                                                                                      'go8o      0                  00 0          4)                                                                    0 90,0-0-09 0,0     ON 0                                  000 0 o     0-0                   0 X0 0&#xfd; ,,'&sect; 06&#xfd;O'                                                        ozol(&#xfd;                                                   0                        N g            o 100                                                    &#xfd;559&#xfd;0           &#xfd;80- 10&#xfd;O                                          0                                                                         --      &#xfd;.-q 060606
Aq 200 130 0
                                                                              'D    1            0106 0.9        60100      01                  10 0            0                  00&#xfd;0 0 8    0 0 &#xfd; 0          --        0       0                 60                            0 100 0 91,0                     620 ". "- 0                                                         0            060 0              00      og        010                                      0          01             :010        0
a 06co 00 &#xfd;'&#xfd;a 430 P'6 &Q p
                                                      '*008' 0,08-0,6868 0 0                     g'301 0                  1 00                    0             O'S lo&#xfd;         0 0                   o 13"                  0 0                                                                                                                                                                                                     C            'Q        Q          9 601-1go0          0                   -0 g                                                                                011)                S&#xfd; so s0                                                                                                1        j                          0                                                                 0 00         0 9 0                   0 000       10                                                    0                  NO.                o    S 00      0000    0,                                     10 00                        0   0     010 0
0 0 0&#xfd;0&#xfd;0&#xfd;0 080&#xfd;080&#xfd;0 0 00 00 10, 6 U616 16, 90 0
00 0 0            Z&#xfd;Z                    -  -0                                                   ,,      9.        0..                            0 R?                                                                                        0.19a                                  02                                      9.0 01&#xfd;.01 80                                                                                                                                                                                    0                                                                                                                     -      -
go 0
r'=6&#xfd;                          I
go jooso "v 0 9 0 0-0 a 6-0  
                                  '&#xfd;-o0      &#xfd;0608qv.06 -            0         00                                                                                                                                                                     0'Q'00                 'O'Z)401 60    0                                             00       go 00,   lp                              1&#xfd; 010        0                  go 9000 goo        6,000 "G0                            0 0 0         0 0 0        0 160            0                  0,00,0'&#xfd;)0,0                                                                          ON".,
' ' 2 0
11        MR                                  0-0 "(20" g-                .0-0.
00106100'0'00&#xfd; 200" 00 0 10-0220'0&#xfd;  
                                                                                                                                                      .0     0                O-P.-O 43 0  4D                                  0&#xfd;                 0'g&#xfd;                                                             -
?00 50040roo 0
70 6      6v vo'&#xfd;'      0      16 'n 0&#xfd;0 Q       Q&#xfd;q&#xfd;' 0&#xfd;0               00                                  10                            0    00 0   0     0       0                   6          0     0                                                                           0   10 0   0 00     0     0                                      0                                                                                            0                            lcl&#xfd;00 0   0  0                       &#xfd;0
9  
                                                                                                                -0      L.11&#xfd;1                                                                                                  lolol    lo                        6ao;0-6        0   00 N.     l'&#xfd; &#xfd;                      gg-                                                                    -            XXX 0 V          0 &#xfd;211                                                                                      9,      9&#xfd;'-                      "9&#xfd;2                -
-0 a,
C 0                 0'0'.'M
69 o.
                                                                                                                                                                                                ' OYY--6
0 0-OX M&#xfd;.5'0iP5'.Q'0 &#xfd;26262528 62526262o -1
                                                                                                                                                                                                      -                    01                    01010 10go          0 0         0 0 0 0           0           0
:'-6'-26-206-'26 6 6 11600600 041, 000 00 00 00 0 0 0 6-,6 0 0 10 696 9
                                                                                                              "- o                    0,                  0   0 000                 01-0              0,6,0,20_ 6, 0000000092        '6'                                                                              0000000,0    '0&#xfd; 0,0Q'00' v&#xfd;'Q    0        'o                0   16g 00      0   0 (5 0- -0                                   0         0                        0 0,                         0 0,    o  010 262 2                                                                                                                                                                                                                      116&_6yo&#xfd;'  "o     0'"      O.-;o90,0, "00       OR      &#xfd;qo so 1        0   0   0 0                           Mo 62 0 06- 160 11610, '6&#xfd;                0   0   Qu                            OZO                "1'  0.0                                                                                 Q6Q                                      10 goo    0,10              E0600600610&#xfd; "I          1    0610 060            &#xfd;Q o                     0&#xfd;0                                          41            0  0                                                              0      0                              0 010                  0 0
'01 010 0
                                                                                                                                                                                                                                                                      ?vROK.W. 0-              ';
0
Q 0 60        0--                          -6 110  600,0               oo'&#xfd;. 0 R -5 6'0 192%0 5:05ya-No        0yo-06-00yo      010&#xfd;W'0'0 Yolyol
.'4'. 0 0.-.0 00 OR 0
                                                                                                                                                                                  &#xfd;'O&#xfd;o
0 0
                                                                                                                                                                                            '0
0 I solo 0,00  
                                                                                                                                                                                          . R, 1'0'vo&#xfd;'o                                                                                   op    0 010                00o 40                                                                                                                                                                R MS.                                    ogv".go       Q      0              .6     0 0 40 g      3Q.6,6                      6                                                                                                                                                        0           0o OV0      606      ;6,'&Q,6oQ48:                        Q6M6vp: 6                      &o"      v v                                                        9                                0" 6&#xfd; 51011.0 01,0'00,0  0,00,o9    0         0      o                                        6'' 6('
&#xfd;-'00:'52'0;'o ERR-0, 0 0 CR, 0("
01                                                                                                                                                        00        0                                              '000              0 0 '10-                  o          000 0                    &#xfd;Q00                        -g    06                                                                        0 0
2-'0200 000 v
o.'-',o- `-N'.
2n'&#xfd; "I
B 0 0
9 MQ
-zo Q&#xfd; on.
890&#xfd; Ito 060606060 060606060 0 01 0
01 0&#xfd;0 o 100&#xfd;0 0
1 0 0 'go8o 0
0,0 0,0 ON 0
0 "Q Q-?Ugo 6006000 6 go 01 10 10
&#xfd;0 000 00 0
0 0
'00 0 C 00000 0000009,0,00 8`1 0 r"00 09, 3g" 0
l'o.0,0,0"0, 0.,. Qo,.,
: 0.
0 0 0
00 0 0 000 o 0-0 01OX0
: 4) 9 09 0 0
ozol(&#xfd;
&#xfd;559&#xfd;0 10&#xfd;O X0 0
0 N
0606 U Q-I
&#xfd;80-0 &#xfd;,,'&sect; 06&#xfd;O'
&#xfd;.-q g
o 0106 0 0 0 0 010 0
0 01
:0 0.9 1
'D 06 60100 01 10 0 0
00&#xfd;0 8 &#xfd; 0
0 6
0 10 0
100 0 91, 0 620 ". " -
0 060 0
00 og 0
01 0 0
0 0
0 go lp
'*008' 0,08-0,6868 0 0 g'3 1
00 0
O'S lo&#xfd; 0 0 o 13" 0
C
'Q Q
9 0
S&#xfd; 601-1go 0 0  
-0 g 011) so 1
j 0
0 0 0 9 0 0
00 0 0 010 00 000 10 0
NO.
10 0
o S 00 0..
00 0,
: 9.
0 0 0 Z&#xfd;Z 0.19 -
-0 a
02 R?
9.0 01&#xfd;.01 r'=6&#xfd; I
'&#xfd;-o 0  
&#xfd;0608qv.06 -
0 00 0'Q'00
'O'Z)401 16 60 0
00 00, 1&#xfd; go 000 9
goo 0
0 0 0 0 0 0 0 0 0
0,00,0'&#xfd;)0,0 ON".,
010 0
6,000 "G 43 0 4D 0&#xfd; 0'g&#xfd; 0-0 "(20" g-
.0-0. 0 11 MR
.0 O-P.-O 6
6v vo'&#xfd;'
0 16 'n 0 0 0
0 6
0 10 0 0
0&#xfd;0 Q Q&#xfd;q&#xfd;'
0 0 0
00 0&#xfd;0 10 0
0 00 0
0 0
0 lcl&#xfd; 00 0 0 0  
&#xfd;0
-0 L.11&#xfd;1 lolol lo V
6ao;0-6 0 00 gg-XXX 0 0 &#xfd;211 "9&#xfd;2 N.
l'&#xfd; &#xfd; 9,
9&#xfd;'-
000 0,6,0,20_ 6, '6'
'0&#xfd; 0,0 0,
0'.'M 10go 01-0 v "- o 0
0 C 0 0' ' -
01 OYY--6 01010 0 0 0 0 0 0 0
0 0000000092 0000000,0 Q'00' &#xfd;'Q 0  
'o 0
16 00 0 0
(5 0- -0 0
0 0
0, g 0 0, o 010 "o
O.-;o 90,0, "00 OR
&#xfd;qo
_6yo&#xfd;'
262 2 116&
0 1
0 0 0 0 Mo 0 160 11610, '6&#xfd; 0
Qu "1'
0.0 62 06-0 OZO Q6Q 10 goo 0,10 E0600600610&#xfd; "I 1
0610 060
&#xfd;Q o 0&#xfd;0 41 0 0 0
0 0 010 0
0  
-No Yolyol
. 1'0'vo&#xfd;'o ogv".go  
.6 0 0 0
0o Q 0 11 0 600,0 0
010 &#xfd;W'0'0  
'0  
?vROK.W. 0-R 60 0--
192%0 5:05ya 0yo-06-00yo 0
-6 oo'&#xfd; 0 R -5 6'w
&#xfd;'O&#xfd;o 0o MS.
R, 40 g
3Q.6,6 6
Q 0
op 0
010 01,0'00,0 0,00,o 9 0 0
o OV 0 606
;6,'&Q,6oQ48:
6' ' 6('
Q6M6vp: 6
&o" v v 9
0" 6&#xfd; 51011.0 01 00 0
'000 0
0 O&#xfd;.
0
)0000 000. 00QP'Q8Qo 0 5-0.1 0 2-P.
&#xfd;'Vi R.
N.
0 '10-o 000 0
&#xfd;Q 00
-g 06 0 0
-0 oi.. 00.,,
OPP
.01v "M.
&OP 0
"-Q 0.19.
0
-'o 0 0-0 0-"
0 Nog 0
&#xfd;5?090yn
-Oyd-
-MISL 6
30 60;06 000 0
06 0":
0 0
0 Q6o'5Q6Q
: 00.
0 0
9 Y'0
&#xfd;fqyq o
010 q0' oyop&#xfd;o 0
010900168 000 0
0 0 9
00 C' 0
0 0 0 0 0go 9,00 10 5 00 00, 010 0 0
.'0 0 0 0
0Q'00'0Q'0' 20 a'292.a'&#xfd; 6 6-20 101&#xfd;1.01-01 0 0
K i go&#xfd;. 00 0 "R. '121" 1&#xfd;c ZU g
0 006 00600600600&#xfd;00 0 e&#xfd; 1W ovq'Xq o
60,6,Z
-0 so 40 30 20 01O0%00c005 1
0 x 0
1 1;
0
0
                                                  -'o
.oo7 0
                                                                                )0000 000. &OP
oqqgg&#xfd; Z.p
                                                                              &#xfd;5?090yn            00QP'Q8Qo
.'0 qrs&#xfd;&#xfd;'
                                                                                                        -Oyd-0 -MISL 0-00 5-0.1 0-" 06    0 2-P.0 00    Nog                            -0                      &#xfd;'Vi oi.. 00., 0,R.OPP        N.    .01v      "-Q    "M. 0.19.
0-ozo-q- -oza-&#xfd;-
O&#xfd;.
1^0*
30                                      60;06000                0      06        0":          0    -              0        0                                                                          Q6o'5Q6Q              01000.                                                    0        0  9 30 Y'0              &#xfd;fqyq    o q0'      oyop&#xfd;o        00        0 0go 9,00 0000            10            00                        5 0000,              010
Q~V5?6V6V6A5V~
                                                                                                                                        .'0                                                              0      010900168    :  9 0 000    C'                                                                    0  00 0 0
6 ~ jp~co~o~0. &~~5~5Thft'&'
0Q'00'0Q'0'                                20 a'292.a'&#xfd;                                                    6 6-20 20    101&#xfd;1.01-010 0            0      K i go&#xfd;. 00                              0 "R. '121"1&#xfd;c                                                                                                                                            ZU          ,
3Q5Y6 taL?&~
o 60,6,Z   g 006 00600600600&#xfd;00 01O0%00c005 0
1 1  
x 0
+
1 1 0
10 0000' 0 0 0 0 0 o.
1;
0 o
                                                                      .oo7 6~
0 Oo 00 0oo o 00oto-o-00 0000000 00 r,
0 e&#xfd;
ooe~~-bv T,
                                                                                                                                                                                                                                                                - .'0 0Z.p oqqgg&#xfd;          -0                1W qrs&#xfd;&#xfd;'0-ozo-q-ovq'Xq
0*'&#xa2;0  
                                                                                                                                                                                                                                                                                                          -oza-&#xfd;-                 1^0*
&deg;>
t 3Q5Y6aL?&~
04 000000
Q~V5?6V6V6A5V~                     jp~co~o~0. &~~5~5Thft'&'                                     1               1               +                                                                                                                                                           10 0000' 0 00 00 0 0                                                                                                                                                                                                                            04                      (.      0      ol"                          0 o.o     Oo 00 r, 0oo oooe~~-bv 00oto-T, o-00        0*'&#xa2;0 0000000                00
(.
                                                                                                                      &deg;>                                                                                                   000000 0o% - %%        :s, qgaag gg 10               20               so               40                 s0                 Go               70               80               90             100               110                 10               ISO               140                 1S             ISO               170
0 ol" 0 -
o%
0
:s, gaa q g gg 10 20 so 40 s0 Go 70 80 90 100 110 10 ISO 140 1S ISO 170


Inspection of Steam Generator Tubes                         Appendix 2 Special Report                                              Page 1 of 2 Appendix 2 Legend for Appendices 3 and 4
Inspection of Steam Generator Tubes Special Report Appendix 2 Page 1 of 2 Appendix 2 Legend for Appendices 3 and 4


Inspection of Steam Generator Tubes                                                                     Appendix 2 Special Report                                                                                          Page 2 of 2 List of Abbreviations and Format Used to Describe Indications from Rotating Probe Testing Abbreviati ons                                Explanation of the Abbreviations SCI             Single Circumferential Indication MCI             Multiple Circumferential Indications SAI             Single Axial Indication MAI             Multiple Axial Indications MMI             Mixed Mode Indications SVI             Single Volumetric Indication (i.e. no special axial or circumferential aspect)
Inspection of Steam Generator Tubes Special Report Appendix 2 Page 2 of 2 List of Abbreviations and Format Used to Describe Indications from Rotating Probe Testing Abbreviations Explanation of the Abbreviations SCI Single Circumferential Indication MCI Multiple Circumferential Indications SAI Single Axial Indication MAI Multiple Axial Indications MMI Mixed Mode Indications SVI Single Volumetric Indication (i.e. no special axial or circumferential aspect)
MVI             Multiple Volumetric Indications (i.e. no special axial or circumferential aspect)
MVI Multiple Volumetric Indications (i.e. no special axial or circumferential aspect)
PCS             Partially Collapsed Sleeve TWD             Through Wall Depth (an indication of tubing wear used for volumetric wear indicated with a percent value shown in the next column)
PCS Partially Collapsed Sleeve TWD Through Wall Depth (an indication of tubing wear used for volumetric wear indicated with a percent value shown in the next column)
Format In Appendices 3 and 4, a single line of data is associated with each individual indication. Below is a descriptive example of the format.
Format In Appendices 3 and 4, a single line of data is associated with each individual indication. Below is a descriptive example of the format.
The example above displays the format of a Report line. The VOLTS field contains the voltage of the largest, most representative response. The DEG field contains the corresponding phase angle. The CHN field contains the reporting channel (e.g., the appropriate axially or circumferentially sensitive 300kHz Plus Point channel). The IND field contains the appropriate 3-letter code (see list above). The
The example above displays the format of a Report line. The VOLTS field contains the voltage of the largest, most representative response. The DEG field contains the corresponding phase angle. The CHN field contains the reporting channel (e.g., the appropriate axially or circumferentially sensitive 300kHz Plus Point channel). The IND field contains the appropriate 3-letter code (see list above). The
%TW field indicates the percent wall loss for wear indications. The LOCATION field contains the abbreviation for the referenced landmark and the distance to the indication. The EXT fields contain the landmarks of the beginning and end of the test extent. The CAL# field identifies the calibration number associated with the acquired data. The LEG field identifies the Hot or Cold Leg as the location of the probe origination. The PROBE field contains the abbreviated identifier of the probe type used for the inspection. For the second column, the terms line and column are used interchangeably for Combustion Engineering designed steam generators.
%TW field indicates the percent wall loss for wear indications. The LOCATION field contains the abbreviation for the referenced landmark and the distance to the indication. The EXT fields contain the landmarks of the beginning and end of the test extent. The CAL# field identifies the calibration number associated with the acquired data. The LEG field identifies the Hot or Cold Leg as the location of the probe origination. The PROBE field contains the abbreviated identifier of the probe type used for the inspection. For the second column, the terms line and column are used interchangeably for Combustion Engineering designed steam generators.


Inspection of Steam Generator Tubes                       Appendix 3 Special Report                                            Page 1 of 14 Appendix 3 Tube Inspection Summary Steam Generator E-088
Inspection of Steam Generator Tubes Special Report Appendix 3 Page 1 of 14 Appendix 3 Tube Inspection Summary Steam Generator E-088
 
AREVA NP InC Customer Name: San Onofre -
Unit 2 01/09/08 14:19:36 Component: S/G 88 Page 2 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMi[l]
ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 1
133 0.40 0
P2 TWD 18 04C
-0.17 07C TEC 6
COLD 600UL 6
138 0.15 87 2
SAI 07H
-0.98 07H 07H 156 HOT 580PP 6
168 0.37 130 P2 TWD 18 04H
-0.31 TEC TEH 23 HOT 600UL 7
55 0.32 110 2 SAI 07C
+0.97 07C DBC 109 COLD 5809P 7
137 0.57 27 P1 SCI TSH
-1.95 TSH TSH 86 HOT 580PP 7
143 0.33 20 P1 SCI TSH
-4.84 TSH TSH 85 HOT 580PP 8
156 0.57 24 Pl SCI TSH
-0.15 TSH TSH 85 HOT 580PP 9
51 0.27 77 2
SAI 03H
-0.32 03H 03H 212 HOT 520ET 10 40 0.23 22 P1 SCI TSH
-0.08 TSH TSH 76 HOT 580PP 11 147 0.57 22 P1 SCI TSH
-0.07 TSH TSH 83 HOT 580PP 12 24 0.27 104 2 SAI 06H
-0.13 06H 06H 169 HOT 580PP 13 9
0.34 98 P2 TWD 14 05H
-0.14 TEC TEH 25 HOT 60OUL 13 47 0.33 21 P1 SCI TSH
-0.02 TSH TSH 80 HOT 580PP 13 55 0.26 69 2
SAI 05H
+0.64 05H 05H 183 HOT 580PP 13 159 0.14 45 P3 TWD 8 DBH
-2.25 TEC TEH 19 HOT 600UL 14 126 0.40 17 P1 SCI TSH
-0.15 TSH TSH 70 HOT 580PP 14 130 0.45 24 P1 SCI TSH
-0.06 TSH TSH 74 HOT 58OPP 15 119 0.43 133 P2 TWD 19 07C
-0.96 TEH TEC 49 COLD 600UL 15 141 0.27 23 P1 SCI TSH
-2.80 TSH TSH 79 HOT 58022 16 140 0.51 17 P1 SCI TSH
-8.44 TSH TSH 78 HOT 580PP 17 15 0.55 16 2
SAI TSH
-6.03 TSH TSH 72 HOT 580PP 0.55 13 2
SAI TSH
-6.32 TSH TSH 72 HOT 58OPP 17 57 0.31 123 2 SAI 01H
+0.75 01H 01H 189 HOT 580PP 0.22 97 2
SAI 06H
+0.58 06H 06H 189 HOT 580P2 17 59 0.42 15 2
SAI TSH
-1.09 TSH TSH 87 HOT 5802P 18 34 0.32 19 P1 SCI TSH
+0.05 TSH TSH 49 HOT 5802P 18 44 0.23 113 P3 TWD 10 DBH
-2.00 TEC TEH 13 HOT 60OUL 19 47 0.52 18 P3 TWD 19 DBC
+1.66 TEH TEC 37 COLD 600UL 19 135 0.36 147 P3 TWD 18 DBH
+2.00 TEC TEH 11 HOT 600UL 19 141 0.50 14 2
SAI TSH
-6.13 TSH TSH 79 HOT 580PP 20 68 0.37 68 P3 TWD 13 DBH
-1.71 TEH TEC 39 COLD 600UL 20 108 0.14 43 P3 TWD 6 DBH
-1.54 TEH TEC 50 COLD 600UL 20 120 0.42 16 P1 SCI TSH
-0.19 TSH TSH 64 HOT 580PP 21 31 0.48 23 P1 SCI TSH
-14.04 TSH TSH 52 HOT 580PP 21 61 0.47 17 P3 TWD 17 DBC
+1.98 TEH TEC 38 COLD 600UL 21 63 0.35 105 2 SAI 07C
-0.85 07C 07C 113 COLD 58OPP 21 67 0.32 79 P3 TWD 12 DBH
+2.00 TEH TEC 38 COLD 600UL 0.34 141 P2 TWD 13 VSM
+0.76 TEH TEC 38 COLD 600UL 21 113 0.52 17 2
SAI TSH
-2.37 TSH TSH 65 HOT 58OPP 21 127 0.18 107 2
SAI 04H
+0.77 04N 04H 150 HOT 580P2 21 129 0.31 52 P1 SCI TSH
-0.09 TSH TSH 65 HOT 5802?
 
AREVA NP Inc Customer Name:
San Onofre -
Unit 2 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, NVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMI[1].qry 01/09/08 14:19:36 Component:
S/G 88 Page 3 of 14 ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL 22 52 0.31 60 2
SAI 03H
-0.70 03H 03H 212 23 109 0.47 113 P2 TWD 20 VSM
+1.02 TEH TEC 50 0.51 15 2
SAI TSH
-0.79 TSH TSH 64 0.58 15 2
SAI TSH
-0.57 TSH TSH 64 0.26 14 2
SAI TSH
-1.15 TSH TSH 64 24 14 0.11 23 P2 TWD 7 VSM
+0.88 TEC TEH 22 24 64 0.95 13 2
SAI TSH
-0.81 TSH TSH 89 LEG PROBE HOT 520ET COLD 60OUL HOT 580PP HOT 580PP HOT 580PP HOT 60OUL HOT 580PP 24 156 0.38 101 P2 TWD 17 03H
+0.88 TEC TEH 20 HOT 60OUL 24 160 0.20 85 2
SAI 06H
-0.06 06H 06H 155 HOT 580?P 25 117 0.39 22 P1 SOI TSR
-0.16 TSH TSH 65 HOT 580PP 25 133 0.53 25 P1 SCI TSH
-0.13 TSH TSH 75 HOT 580PP 0.70 22 P1 SCI TSH
-0.14 TSH TSH 75 HOT 580PP 26 146 0.15 16 P3 TWD 5 DBH
+0.74 TEC TEH 16 HOT 60OUL 27 61 0.92 15 2
SAI TSH
-1.20 TSH TSH 89 HOT 580PP 0.87 14 2
SAI TSH
-4.41 TSH TSH 89 HOT 580PP 27 159 0.23 99 2
SAI 02H
+0.03 02H 02H 155 HOT 580PP 0.49 97 2
SAI 03H
+0.87 03H 03H 155 HOT 580PP 0.28 50 2
SAI 02H
+0.79 02H 02H 155 HOT 580PP 28 120 0.52 18 2
SAI TSH
-6.66 TSH TSR 64 HOT 580PP 30 8
0.24 96 2
SAI 03H
+0.85 03H 03H 169 HOT 580PP 30 38 0.51 18 P1 SCI TSH
-0.08 TSH TSH 102 HOT 580PP 30 52 0.22 73 2
SAI TSH
+0.66 TSH TSH 81 HOT 580PP 31 11 0.29 97 P3 TWD 11 DBH
+1.80 TEC TEH 25 HOT 600UL 31 65 0.54 10 P3 TWD 19 DBC
+2.00 TEH TEC 38 COLD 600UL 31 67 0.61 21 P1 SCI TSH
-0.06 TSH TSH 89 HOT 580PP 31 69 0.57 11 2
SAI TSH
+0.00 TSH TSH 93 HOT 5802P 31 107 0.80 15 2
SAI TSH
-1.05 TSH TSH 64 HOT 580PP 31 123 0.28 98 2
SAI 05H
+0.66 05H 05H 150 HOT 580PP 31 165 0.76 23 2
SAI 05H
-0.34 05H 05H 159 HOT 58OPP 0.60 14 2
SAI 05H
+0.39 05H 05H 159 HOT 5802P 0.39 16 2
SAI 05H
+0.54 05H 05H 159 HOT 580PP 32 4
0.31 131 P2 TWD 16 01C
-0.92 TEC TEH 26 HOT 60OUL 32 112 0.81 16 2
SAI TSH
-1.63 TSH TSH 65 HOT 580PP 0.69 15 2
SAI TSH
-2.08 TSH TSH 65 HOT 580PP 32 122 0.74 15 2
SAI TSH
-0.88 TSH TSH 71 HOT 58022 33 37 0.42 24 P1 SCI TSH
-0.10 TSH TSH 48 HOT 5802?
33 105 0.50 6
P3 TWD 21 DBC
+1.53 TEC TEH 36 HOT 600UL 0.31 144 P3 TWD 14 DBH
-1.69 TEC TEH 36 HOT 60OUL 0.20 82 P3 TWD 10 DBC
-1.59 TEC TEH 36 HOT 60OUL 34 108 0.66 19 2
SAI TSH
-0.77 TSH TSH 64 HOT 580PP 35 27 0.34 87 P2 TWD 14 VSR
+0.72 TEC TEH 17 HOT 600UL 0.37 77 22 TWD 15 VSM
-0.74 TEC TEH 17 HOT 600UL 35 69 0.47 15 2
SAT TSH 35 71 0.53 100 P3 TWD 19 DBC 36 70 0.75 14 2
SAI TSH 0.51 12 2
SAI TSH 0.70 14 2
SAI TSH
-1.07 TSH TSH 93 HOT 580PP
-1.90 TEH TEC 38 COLD 600UL
-1.59 TSH TSH 93 HOT 580PP
-3.11 TSH TSH 93 HOT 580PP
-3.93 TSH TSH 93 HOT 580PP 37 47 0.47 107 P2 TWD 20 VSM
+0.88 TEH TEC 317 COLD 600TUL
 
AREVA NP Inc Customer Name:
San Onofre -
Unit 2 01/09/08 14:19:36 Component:
S/G 88 Page 4 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCA 37 61 0.36 154 P2 TWD 14 VSM 37 71 0.66 15 2
SAI TSH 37 103 0.54 23 P3 TWD 22 DBH 38 28 0.23 90 2
SAI 0H 0.44 68 2
SAI 05H 38 110 0.79 13 2
SAI TSH 0.55 12 2
SAI TSH TION EXT EXT CAL # LEG PROBE
+0.93 TEH TEC 38 COLD 60OUL
-2.58 TSH TSH 93 HOT 580PP
-2.10 TEC TEH 35 HOT 60OUL
+0.33 01H 01H 169 HOT 580PP
-0.67 05H 05H 169 HOT 580PP
-1.44 TSH TSH 64 HOT 580PP
-0.65 TSH TSH 64 HOT 58OPP 39 43 0.46 10 P3 TWD 17 DBC
+1.33 TEC TEH 13 HOT 60OUL 39 71 0.35 128 P3 TWD 13 DBC
-1.55 TEH TEC 38 COLD 60OUL 40 58 0.41 15 2
SAI TSH
-3.72 TSH TSH 88 HOT 58OPP 40 162 0.31 120 2 SAI 06H
+0.25 06H 06H 158 HOT 580PP 41 7
0.40 137 P2 TWD 16 VSM
-0.77 TEC TEH 25 HOT 60OUL 41 39 0.71 12 P1 SCI TSH
-1.42 TSH TSH 48 HOT 580PP 41 69 0.69 11 2
SAI TSH
-2.14 TSH TSH 93 HOT 58OPP 41 73 0.41 110 P2 TWD 17 VSM
+0.93 TEH TEC 39 COLD 60OUL 0.23 34 P3 TWD 9 DBC
+1.43 TEH TEC 39 COLD 60OUL 41 101 0.17 85 P3 TWD 6 DBH
-1.79 TEC TEH 28 HOT 60OUL 0.22 53 P3 TWD 8 DBC
+1.91 TEC TEH 28 HOT 60OUL 42 14 0.16 140 2 SAI DBH
-0.81 DBH DBH 130 COLD 560P2 0.20 122 2 SAI DBH
-0.11 DBH DBH 130 COLD 560P2 42 74 0.36 86 P3 TWD 13 DBC
+1.32 TEH TEC 39 COLD 600UL 0.32 34 P3 TWD 12 DBC
-1.68 TEH TEC 39 COLD 600UL 42 106 0.71 126 P2 TWD 30 VSM
-0.98 TEC TEH 35 HOT 60OUL 0.46 14 2
SAI TSH
-1.18 TSH TSH 64 HOT 580PP 42 158 0.21 152 P3 TWD 11 DBH
+1.72 TEC TEH 19 HOT 60OUL 43 19 0.59 95 P2 TWD 25 02H
+0.87 TEC TEH 22 HOT 60OUL 43 51 0.93 105 P2 TWD 31 VSM
+0.88 TEH TEC 37 COLD 600UL 43 57 0.37 57 P3 TWD 13 DBH
+1.68 STH TEC 41 COLD 60OUL 0.22 46 P3 TWD 8 DBC
+1.72 STH TEC 41 COLD 60OUL 43 73 0.27 82 P3 TWD 11 DBC
-1.89 TEH TEC 38 COLD 600UL 0.65 15 2
SAI TSH
-3.90 TSH TSH 93 HOT 58OPP 43 101 0.34 58 P3 TWD 12 DBC
-1.68 TEC TEH 27 HOT 600UL 0.55 176 P3 TWD 19 DBC
+1.66 TEC TEH 27 HOT 600UL 43 125 0.57 106 P2 TWD 23 VSM
-0.84 TEH TEC 50 COLD 60OUL 44 58 0.22 21 P2 TWD 10 VSM
-1.08 TEH TEC 39 COLD 600UL 0.47 109 P2 TWD 19 VSM
+0.86 TEH TEC 39 COLD 600UL 44 108 0.27 81 P2 TWD 13 VSM
+0.87 TEC TEH 36 HOT 60OUL 0.34 132 P2 TWD 16 VSM
-0.77 TEC TEH 36 HOT 60OUL 44 124 0.38 107 P2 TWD 17 VSM
-0.95 TEH TEC 50 COLD 60OUL 45 73 0.38 126 P3 TWD 13 DBC
-1.61 STH TEC 41 COLD 60OUL 45 145 0.24 80 P2 TWD 12 VSM
+0.88 TEC TEH 15 HOT 60OUL 46 6
0.26 141 P3 TWD 13 DBC
+1.63 TEC TEH 26 HOT 60OUL 0.41 39 P2 TWD 19 VSM
-0.75 TEC TEH 26 HOT 60OUL 46 148 0.24 122 2 SAI 01H
-0.16 0H 01H 155 HOT 58OPP 47 109 0.38 90 P2 TWD 14 VSM
-0.02 STH TEC 41 COLD 60OUL 0.45 107 P2 TWD 16 VSM
+0.88 STH TEC 41 COLD 600UL 47 111 0.35 11 2
SAI TSH
-3.12 TSH TSH 64 HOT 58OPP
 
AREVA NP Inc Customer Name: San Onofre -
Unit 2 01/09/08 14:19:36 Component:
S/G 88 Page 5 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.84 19 2
SAI TSH
-0.87 TS1 TSH 64 HOT 58OPP 47 125 0.36 77 P2 TWD 16 VSM
+0.78 TEH TEC 50 COLD 600UL 47 143 0.15 78 2
SAI 01H
-0.03 01H 01H 155 HOT 580PP 48 76 0.58 90 P3 TWD 19 DBC
-1.75 TEC TEH 27 HOT 600UL 0.18 7
P3 TWD 6 DBH
+1.47 TEC TEN 27 HOT 60OUL 48 114 0.29 139 P3 TWD 14 DBH
-1.59 TEH TEC 49 COLD 60OUL 48 124 0.28 25 P1 SCI TSH
-0.10 TSH TSH 65 HOT 580PP 48 134 0.57 19 P1 SCI TSN
-0.07 TSH TSH 78 HOT 580PP 49 47 0.14 105 2 SAI 08C
-1.17 08C 08C 113 COLD 580PP 49 69 0.41 113 P2 TWD 16 08C
-1.22 TEH TEC 38 COLD 600UL 49 75 0.41 88 P3 TWD 17 DBH
-1.78 TEN TEC 36 COLD 600UL 50 8
0.28 131 P2 TWD 14 VSM
+0.77 TEC TEH 26 HOT 600UL 50 98 0.52 70 P2 TWD 22 VSM
-0.92 TEC TEH 28 HOT 60OUL 50 102 0.40 15 2
SAI 13W
-0.42 TSN TSN 127 NOT 580PP 50 106 0.41 13 2
SAI TSH
-0.07 TSH TSH 127 HOT 580PP 50 110 0.23 60 P2 TWD 12 08H
+0.87 TEC TEN 31 HOT 60OUL 50 148 0.38 101 2 SAI 08H
+0.81 08H 08H 155 HOT 58OPP 50 164 0.40 115 P2 TWD 18 VSM
+0.82 TEC TEH 20 HOT 600UL 51 55 0.29 114 P1 SCI TSH
+0.03 TSH TSH 87 HOT 58OPP 51 57 0.36 94 P1 SCI TSH
+0.06 TSH TSH 87 HOT 580PP 51 81 0.85 121 P3 TWD 26 DBC
-1.61 TEC TEH 27 HOT 600UL 0.46 169 P3 TWD 16 DBH
+1.43 TEC TEH 27 HOT 600UL 0.58 142 P3 TWD 19 DBH
-1.55 TEC TEH 27 HOT 60OUL 0.79 133 P3 TWD 25 DBC
+1.85 TEC TEH 27 HOT 600UL 51 117 0.69 21 P1 SCI TSH
-0.10 TSH TSH 64 HOT 58OPP 51 155 0.21 108 2 SAI 04H
+0.75 04H 04H 155 HOT 58OPP 51 163 0.39 41 P2 TWD 17 VH3
+0.90 TEC TEH 20 HOT 600UL 52 72 0.17 105 2 52 76 0.37 60 P3 52 112 0.79 15 2
0.51 12 2
0.67 15 2
0.45 13 2
SAI TSH TWD 13 DBC SAI TSH SAI TSH SAI TSH SAI TSH
+0.23 TSH TSH 94 HOT 580PP 53 57 0.28 98 P1 MCI TSH
+
53 113 0.68 14 2
SAI TSH 0.43 12 2
SAT TSH 0.74 14 2
SAi ISE 54 8
0.39 124 P2 TWD 18 01H
+
0.18 123 P2 TWD 10 01H 54 38 0.49 20 P1 SCI TSH 54 60 0.17 112 2 SAI TSH
+
54 72 0.20 79 P!
SCI TSH
+
54 76 0.41 48 P3 TWD 14 DBC 1.55 TEC TEN 27 HOT 60OUL 1.87 TSH TSH 65 HOT 580PP 2.57 TSH TSH 65 HOT 58OPP 3.37 TSH TSH 65 HOT 580PP 3.67 TSH TSH 65 HOT 580PP 0.15 1S3 TSH 88 HOT 580PP 5.31 TSH TSH 64 HOT 580PP 3.74 TSH TSH 64 HOT 58OPP 1.74 TSH TSH 64 HOT 58OPP 0.06 TEC TEN 26 HOT 600UL 1.06 TEC TEN 26 HOT 600UL 0.02 TSH TSH 49 HOT 580PP 0.15 TSH TSH 90 HOT 580PP 0.06 TSH TSH 93 HOT 580PP 1.65 TEC TEE 28 HOT 60OUL 1.84 TEC TEH 27 HOT 600UL 1.77 STH TEC 41 COLD 60OUL 54 92 0.10 44 P3 TWD 4 DBH 54 96 0.63 80 P3 TWD 20 DBH
 
AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -
Unit 2 Component:
S/G 88 Page 6 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 55 81 0.43 126 P3 TWD 15 DBH
-1.59 TEC TEH 27 HOT 600UL 55 91 0.61 128 P3 TWD 20 DBH
-1.67 TEC TEH 27 HOT 600UL 55 95 0.58 171 P3 TWD 19 DBC
+1.68 TEC TEH 27 HOT 60OUL 56 78 0.21 111 P3 TWD 8 DBH
-1.47 TEC TEH 28 HOT 600UL 56 80 0.92 141 P3 TWD 27 DBC
-2.00 TEC TEH 27 HOT 600UL 0.59 95 P3 TWD 20 DBH
-1.52 TEC TEH 27 HOT 600UL 0.27 11 P3 TWD 12 DBH
+1.75 TEC TEH 27 HOT 600UL 56 112 0.27 31 P3 TWD 12 DBH
-2.07 TEC TEH 31 HOT 60OUL 56 126 0.39 21 P!
SCI TSH
-0.17 TSH TSH 65 ROT 580PP 56 154 0.53 10 2
SAI TSH
-7.34 TSH TSH 85 HOT 580PP 57 73 0.12 103 21 SCI TSH
+0.09 TSH TSH 94 HOT 580PP 57 91 0.18 142 P3 TWD 8 DBC
-1.66 STH TEC 42 COLD 600UL 57 97 0.73 19 P3 TWD 23 DBH
+1.72 TEC TEH 28 HOT 60OUL 57 105 0.41 20 2
SAI TSH
-2.35 TSH TSH 59 HOT 580PP 57 109 0.37 78 P2 TWD 18 03H
-1.21 TEC TEH 31 HOT 600UL 57 161 0.41 114 2 SAI 06H
-0.41 06H 06H 155 HOT 580PP 57 167 0.52 147 P2 TWD 23 02C
+0.89 T.C TEH 23 HOT 600UL 58 70 0.65 19 2
SAI TSH
-2.27 TSH TSH 93 HOT 580PP 58 96 0.38 147 P3 TWD 15 DBH
-1.80 TEC TEH 27 HOT 600UL 58 100 0.40 57 P2 TWD 18 VSM
-0.80 TEC TEH 28 HOT 600UL 59 23 0.48 100 P2 TWD 19 VH3
-0.92 TEC TEH 21 HOT 600UL 59 25 0.41 155 P2 TWD 18 VH3
+0.84 TEC TEH 18 HOT 60OUL 0.35 138 P2 TWD 15 VH3
-0.82 TEC TEH 18 HOT 600UL 59 83 0.56 18 2
SAI TSH
-1.40 TSH TSH 50 HOT 58OPP 0.30 19 2
SAI TSH
-0.87 TSH TSH 50 HOT 580PP 59 95 0.28 22 P3 TWD 10 DBC
+1.58 TEC TEH 28 HOT 60OUL 59 161 0.41 80 P2 TWD 17 VH3
-0.90 TEC TEH 19 HOT 600UL 60 86 0.23 88 2
SAI VC3
+0.84 VC3 VC3 118 COLD 560P2 0.40 91 P2 TWD 16 VC3
+0.84 STH TEC 42 COLD 600UL 0.49 12 P3 TWD 17 DBH
+1.91 STH TEC 42 COLD 600UL 60 106 0.31 25 P1 SCI TSH
-0.00 TSH TSH 59 HOT 580PP 61 27 0.28 20 P2 TWD 12 VH3
-0.70 TEC TEH 18 HOT 60OUL 61 45 0.20 132 P3 TWD 9 DBC
+0.75 TEC TEH 13 HOT 600UL 61 85 0.27 160 P3 TWD 11 DBC
-1.58 TEC TEN 27 HOT 600UL 0.56 169 P3 TWD 20 DBC
+1.78 TEC TEH 27 HOT 600UL 61 87 0.32 154 23 TWD 11 DBC
-1.98 TEC TEH 27 HOT 60OUL 1.11 23 P3 TWD 31 DBH
+1.75 TEC TEH 27 HOT 600UL 61 125 0.27 143 P2 TWD 12 VC3
-0.10 TEC TEH 32 HOT 600UL 62 80 0.22 73 P1 SCI TSH
+0.03 TSH TSR 51 HOT 580PP 62 114 0.58 18 2
SAT TSH
-2.04 TSH TSH 60 HOT 58022 64 80 0.53 117 P3 TWD 18 DBH
+1.21 TEC TEH 27 HOT 60OUL 64 106 5.92 183 4
PCS SBH
+5.04 TO+13.33 STH SBH 101 HOT 500SP 64 120 0.47 26 P1 SCI TSH
-0.03 TSH TSH 59 HOT 580P2 65 81 0.22 108 P3 TWD 8 DBC
-1.22 TEC TEH 28 HOT 600UL 0.14 125 P3 TWD 6 DBC
+2.00 TEC TEH 28 HOT 600UL
 
AREVA NP Inc Customer Name: San Onofre -
Unit 2 01/09/08 14:19:36 Component:
S/G 88 Page 7 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAT, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 65 87 0.14 78 P1 SCI TSH
+0.06 65 91 0.21 26 P2 TWD 8 VH3
+0.70 65 111 0.41 21 P1 SCI TSH
-0.15 0.75 17 2
SAI TSH
-1.11 66 48 0.41 130 P2 TWD 18 VC3
-0.85 0.31 136 P2 TWD 15 VSM
+0.90 0.56 103 92 TWD 23 VSM
-0.90 67 81 0.62 91 P3 TWD 21 DBC
-1.35 TSH TSH 51 HOT 580PP TEC TEH 27 HOT 600UL TSH TSH 59 HOT 58OPP TSH TSH 59 HOT 580PP TEC TEN 34 ROT 600UL TEC TEH 34 HOT 600UL TEC TEH 34 HOT 600UL TEC TEH 27 HOT 600UL 67 87 0.30 28 P3 TWD 11 DBH
+1.60 TEC TEH 27 HOT 600UL 0.36 148 P3 TWD 13 DBE
-1.36 TEC TEH 27 HOT 600UL 67 111 0.16 103 P1 SCI TSH
+0.16 TSH TSH 60 HOT 58OPP 67 165 0.78 119 P2 TWD 30 VH3
-0.86 TEC TEH 23 HOT 600UL 68 112 0.55 24 P1 MCI TSH
-6.12 TSH TSH 127 HOT 580PP 0.30 18 PT SCI TSH
-9.88 TSH TSH 127 HOT 580PP 68 146 0.53 73 P2 TWD 21 VC3
-0.84 TEC TEH 15 HOT 600UL 68 164 0.57 102 P2 TWD 23 VH3
+0.63 TEC TEH 20 HOT 600UL 69 85 0.24 132 P3 TWD 8 DBC
-1.73 TEC TEH 27 HOT 60OUL 69 87 0.41 134 P3 TWD 15 DBH
+2.00 STH TEC 42 COLD 600UL 69 119 0.51 21 P1 SCI TSH
-0.03 TSH TSH 59 HOT 58OPP 0.37 20 P1 SCI TSH
-0.02 TSH TSH 59 HOT 58OPP 70 82 0.31 159 P3 TWD 11 DBC
+1.88 TEC TEH 28 HOT 600UL 70 86 0.34 51 P3 TWD 13 DBH
-1.42 TEC TEH 27 HOT 60OUL 0.50 15 2
SAI TSH
-2.15 TSH TSH 50 HOT 580PP 0.46 11 2
SAI TSH
-1.84 TSH TSH 50 HOT 580PP 70 104 0.29 109 2 SAI TSH
+0.17 TSH TSH 60 HOT 58OPP 71 13 0.55 123 P2 TWD 21 VH3
-0.79 TEC TEH 21 HOT 60OUL 72 70 0.31 87 P2 TWD 15 VC3
-0.93 TEC TEH 38 HOT 600UL 72 90 0.56 126 P2 TWD 22 VSM
+0.74 TEC TEH 27 HOT 600UL 0.27 29 P2 TWD 11 VSM
-0.98 TEC TEH 27 HOT 600UL 72 100 0.33 132 P1 SCI TSH
+0.05 TSH TSH 50 HOT 580PP 73 17 0.59 98 P2 TWD 22 VH3
-0.82 TEC TEH 21 HOT 600UL 73 75 0.33 135 P2 TWD 15 VC3
+0.60 TEC TEH 38 HOT 60OUL 73 133 0.41 110 P2 TWD 18 VH3
+0.81 TEC TEH 12 HOT 600UL 73 161 0.46 128 P2 TWD 19 VH3
+1.21 TEC TEH 20 HOT 600UL 74 148 0.22 83 P2 TWD 10 VH3
-0.92 TEC TEH 16 HOT 600UL 75 95 0.63 28 P1 SCI TSH
-0.19 TSH TSH 51 HOT 580PP 75 99 0.24 97 P1 SCI TSH
+0.08 TSH TSH 51 HOT 58OPP 75 141 0.33 129 P2 TWD 75 157 0.28 116 P2 TWD 76 18 0.22 96 2
SAI 76 84 0.34 121 P2 TWD 0.35 55 P2 TWD 76 86 0.24 23 P3 TWD 77 31 0.36 131 P2 TWD 0.24 105 22 TWD 14 VH3
-0.93 TEC TEH 16 HOT 600UL 13 VH3
-0.79 TEC TEH 20 HOT 600UL 06H
+0.62 06H 06H 169 HOT 580PP 14 VH3
+0.76 TEC TEH 27 HOT 600UL 15 VH3
-0.84 TEC TEH 27 HOT 600UL 9
DBC
+2.25 TEC TEH 28 HOT 600UL 14 VSM
+0.88 TEC TEH 17 HOT 600UL 11 VSM
+0.33 TEC TEH 17 HOT 60OUL
 
AREVA NP Inc Customer Name:
San Onofre -
Unit 2 01/09/08 14:19:36 Component: S/G 88 Page 8 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[ll.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 77 33 0.41 42 P2 TWD 18 VSM
+0.93 77 39 0.21 135 P3 TWD 11 DBC
+1.57 77 85 0.68 15 2
SAI TSH
-1.92 77 161 0.57 134 P2 TWD 22 VH3
-0.84 78 22 0.56 84 P2 TWD 24 VC3
-0.92 0.53 37 P3 TWD 23 DBC
-1.80 78 74 0.32 20 P1 SCI TSH
-0.06 78 96 0.20 114 P1 SCI TSH
+0.11 78 98 0.38 25 P1 SCI TSH
-0.10 EXT EXT CAL # LEG PROBE TEC TEH 18 HOT 600UL TEC TEH 14 HOT 600UL TSH TSH 50 HOT 580PP TEC TEH 20 HOT 60OUL TEC TEN 22 NOT 600UL TEC TEH 22 HOT 600UL TSN TSH 94 HOT 580PP TSN TSH 51 HOT 58OPP TSH TSH 51 HOT 58OPP 78 102 0.53 28 P1 SCI TSH
+0.00 TSH TSH 59 HOT 580PP 78 120 0.39 29 P1 SCI TSH
-6.00 TSH TSH 60 HOT 580PP 78 138 0.31 41 P3 TWD 14 DBC
+1.47 TEC TEH 12 HOT 60OUL 78 142 0.39 128 P2 TWD 16 VH3
+0.87 TEC TEH 16 HOT 600UL 78 144 0.66 47 P3 TWD 21 DBC
+1.65 TEC TEH 16 HOT 600UL 78 148 0.49 140 P2 TWD 20 08C
-0.92 TEC TEH 16 HOT 600UL 78 154 0.45 128 P2 TWD 19 VC3
+0.82 TEC TEH 20 HOT 60OUL 0.25 162 P2 TWD 12 VC3
-0.80 TEC TEH 20 HOT 600UL 79 15 0.41 19 P3 TWD 16 DBH
+1.45 TEC TEH 21 HOT 60OUL 79 19 0.23 40 P3 TWD 10 DBC
+1.84 TEC TEH 21 HOT 600UL 79 23 0.28 79 P3 TWD 12 DBC
+1.80 TEC TEH 21 HOT 600UL 79 81 0.17 22 P1 SCI TSH
-0.05 TSH TSH 50 HOT 580PP 79 97 0.37 120 P1 SCI TSH
+0.03 TSH TSH 50 HOT 580PP 79 143 0.18 111 P3 TWD 11 DBC
-1.50 TEC TEH 15 HOT 600UL 80 84 0.24 16 P1 SCI TSH
-0.08 TSH TSH 50 HOT 58OPP 80 112 0.32 81 23 0.37 81 93 0.61 81 151 0,35 0,12 82 54 0,74 0,13 82 160 0,25 83 49 0,32 83 87 0,45 115 54 P2 TWD 17 VSM
-0.84 TEC TEH 31 HOT 60OUL P3 TWD 15 DBC
+1.55 TEC TEH 7
HOT 600UL 15 2
SAI TSH
-2.60 TSH TSH 114 HOT 129 P2 TWD 16 VH3
+0.57 TEC TEH 11 HOT 29 P2 TWD 5 VH3
-0.21 TEC TEH 11 HOT 96 P2 TWD 25 VH3
-0.70 TEH TEC 16 COLI 170 P2 TWD 6 VH3
+0.91 TEH TEC 16 COLI 91 P3 TWD 13 DBH
+2.02 TEC TEN 11 HOT 104 2 SAI 02H
+2.02 02H 02H 173 HOT 580PP 600UL 600UL D
600UL D
600UL 600UL 580PP 25 PI SCI TSH 83 99 0,12 123 P3 TWD 5 DBH 84 48 0,64 92 P2 TWD 24 09C 85 43 0,56 131 P2 TWD 19 VH2 86 32 0,17 164 P3 TWD 7 DBC 86 54 0,24 119 P2 TWD 11 VH2 86 130 0.34 94 P2 TWD 17 VC2
-0.12
-1.75 TSH TSH 118 HOT 580PP TEN TEC 23 COLD 600UL TEH TEC 17 COLD 600UL TEC TEH 9
HOT 600UL
-1.50
-1.12
+1.75
-0.77
+--0-66 TEC TEH 7
TEH TEC 16 TEC TEH 6
HOT 600UL COLD HOT 600UL 600UL 87 37 0,36 131 P2 TWD 17 7H2
-0.94 0.38 133 P2 TWD 18 VH2
-1.06 87 63 0,42 116 P3 TWD 17 DBH
-0.25 TEC TEN 10 NOT 600Ut TEC TEN 10 HOT 600UL TEH TEC 19 COLD 600UL
 
AREVA NP Inc Customer Name: San Onofre -
Unit 2 01/09/08 14:19:36 Component:
S/G 88 Page 9 of 14 Post U2C15 Inspection Final Report MAT, MCI, MNT, NVI, SAT, SCI, EVI, 0-100%, PCS QUERY: QueryMlil].gry ROW LINE VOLTS DEG CHN IND
%TW LOCATION 88 60 0.20 91 2
SAI 01H 88 154 0.53 51 P2 TWD 22 VH2 89 35 0.43 94 P2 TWD 16 VH2 89 37 0.56 129 P2 TWD 19 VH2 89 51 0.32 73 P2 TWD 15 VH3 0.42 22 P3 TWD 17 DBH EXT EXT CAL # LEG PROBE
:====::-=---=---- --
 
====
:=
 
========
-=====-===*===:
+2.27 01H 01H 178 HOT 580PP
-0.83 TEC TEH 12 HOT 600UL
-0.93 TEC TEH 7
HOT 60OUL
-0.96 TEC TEH 9
HOT 600UL
+0.80
-1.85 TEH TEC 17 TEH TEC 17 COLD 60OUL COLD 60OUL 89 157 0.18 145 P3 TWD 10 DBH
+1.90 TEC TEH 11 HOT 600UL 90 42 0.24 104 2 SAI VC2
+0.12 VC2 09C 114 COLD 560P2 0.26 118 2 SAI 08H
+0.75 08H 08H 173 HOT 580PP 90 78 0.27 17 P1 SCI TSH
-0.11 TSH TSH 120 HOT 580PP 91 55 0.35 63 P2 TWD 16 VH2
+0.84 TEH TEC 17 COLD 60OUL 91 125 0.36 125 P2 TWD 16 VH2
-0.86 TEH TEC 29 COLD 60OUL 92 26 0.64 86 P2 TWD 25 VH2
-0.79 TEC TEH 8
HOT 600UL 92 36 0.56 87 P2 TWD 23 VH2
-0.89 TEC TEH 10 HOT 600UL 92 56 0.23 102 P2 TWD 12 09H
-0.64 TEH TEC 17 COLD 600UL 93 65 0.35 122 P2 TWD 16 VH2
-0.70 TEH TEC 19 COLD 600UL 93 153 0.37 68 P2 TWD 17 03C
+0.95 TEC TEH 12 HOT 60OUL 0.47 66 P2 TWD 20 05C
-0.89 TEC TEH 12 HOT 600UL 0.19 84 P2 TWD 10 VC3
-0.96 TEC TEH 12 HOT 600UL 94 24 0.41 131 P2 TWD 15 VH2
+1.12 TEC TEH 7
HOT 60OUL 94 40 0.38 119 P2 TWD 15 VH2
+1.12 TEC TEH 9
HOT 600UL 94 48 0.24 106 2 SAI 01H
+0.21 01H 01H 172 HOT 580PP 95 71 0.30 19 P1 SCI TSH
-0.08 TSH TSH 111 HOT 580PP 97 35 0.49 145 P2 TWD 18 VH2
-0.98 TEC TEH 7
HOT 600UL 98 44 0.25 27 P3 TWD 13 DBH
-2.20 TEC TEH 10 HOT 600UL 0.41 70 P2 TWD 18 VSM
+0.75 TEC TEH 10 HOT 600UL 98 94 0.22 89 P1 SCI TSH
+0.00 TSH TSH 114 HOT 580PP 99 49 0.27 18 P3 TWD 11 DBH
-2.00 TEH TEC 17 COLD 600UL 99 131 0.23 150 P2 TWD 12 VH3
+0.67 0.41 102 P2 TWD 19 VH3
-1.01 99 149 0.59 114 P2 TWD 24 VH2
+0.00 TEC TEN 6
NOT 600UL TEC TEH 6
HOT 600UL TEC TEH 11 HOT 600UL 100 102 0.19 21 P1 SCI TSH
-0.07 TSH TSH 54 HOT 58OPP 100 118 0.39 32 P1 SCI TSH
+0.00 TSH TSH 57 HOT 58OPP 101 29 0.45 137 P2 TWD 20 VH2
+0.77 TEC TEH 8
HOT 600UL 101 77 0.49 95 P3 TWD 18 DBH
+1.15 TEH TEC 21 COLD 600UL 101 147 0.56 147 P2 TWD 24 VSE
-0.74 TEC TEH 5
HOT 600UL 102 26 0.33 112 P2 TWD 16 06H
+0.87 TEC TEH 8
HOT 600UL 104 40 0.35 49 P3 TWD 17 DBC
+2.03 TEC TEH 10 HOT 600UL 105 99 106 30 106 106 76 78 0.40 132 P2 TWD 17 03H
+0.74 TEH TEC 23 COLD 60OUL 0.34 122 P2 TWD 14 06H
+0.81 TEC TEH 7
HOT 600UL 0.36 54 P2 TWD 15 02H
-0.20 TEH TEC 21 COLD 600UL 0.21 149 P2 TWO 10 VC2
-0.78 TEN TEC 20 COLD 600UL 0.26 149 P2 TWD 11 VC2
+0.89 TEH TEC 20 COLD 60OUL
 
AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -
Unit 2 Component: S/G 88 Page 10 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[13.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 107 29 0.55 9
P3 TWD 23 DBC
+1.29 TEC TEH 8
HOT 600UL 107 33 0.22 107 P2 TWD 12 09H
-0.37 TEC TEH 8
HOT 60OUL 107 75 0.34 66 P2 TWD 14 09C
-0.29 TEH TEC 7
COLD 60OUL 107 95 0.31 126 P2 TWD 13 VH2
+0.82 TEH TEC 23 COLD 60OUL 107 97 0.28 135 P1 SCI TSH
+0.03 TSH TSH 114 HOT 580PP 0.29 115 P2 TWD 12 VH3
-0.88 TEH TEC 22 COLD 600UL 107 125 0.46 111 P2 TWD 19 VN2
-0.69 TEN TEC 29 COLD 60OUL 0.22 101 23 TWD 9 DBH
-1.42 TEH TEC 29 COLD 600UL 108 36 0.32 79 P3 TWD 15 DBC
-1.80 TEC TEH 10 HOT 60OUL 108 142 0.16 151 P3 TWD 8 DBE
+1.66 TEC TEH 6
HOT 600UL 109 77 0.26 132 P2 TWD 11 VH2
+0.82 TEH TEC 21 COLD 600UL 1i0 52 0.19 97 P3 TWD 9 DBH
-1.33 TEH TEC 16 COLD 600UL 110 96 0.23 91 P3 TWD 9 DBH
+2.24 TEH TEC 23 COLD 600UL 110 138 0.37 116 P2 TWD 18 VC3
-0.90 TEC TEH 6
HOT 600UL I11 33 0.15 11 P3 TWD 8 DBH
+1.75 TEC TEN 8
HOT 600UL 111 37 0.29 20 P3 TWD 14 DBH
+1.85 TEC TEH 10 HOT 60OUL 111 67 0.46 115 2 SAI 02H
+1.06 02H 02H 178 HOT 580PP 11 81 0.23 142 P3 TWD 10 DBH
+2.24 TEN TEC 21 COLD 600UL il1 101 0.21 56 P3 TWD 8 DBH
-0.75 TEH TEC 23 COLD 600UL 112 92 0.35 32 P2 TWD 15 VH2
-0.70 TEH TEC 23 COLD 600UL 112 116 0.15 47 P2 TWD 7 VH3
-0.85 TEH TEC 30 COLD 600UL 112 144 0.86 158 P3 TWD 30 DBH
+2.13 TEC TEH 5
HOT 600UL 113 37 0.36 135 P2 TWD 14 VH2
-0.93 TEC TEN 9
HOT 600UL 0.17 138 P3 TWD 8 DBH
+1.84 TEC TEH 9
HOT 600UL 113 39 0.42 109 P3 TWD 17 DBH
+1.98 TEC TEH 9
HOT 600UL 113 41 0.47 94 P2 TWD 17 VH2
-0.68 TEC TEH 9
HOT 600UL 113 47 0.25 35 P3 TWD 11 DBH
-1.34 TEH TEC 17 COLD 600UL 113 87 0.16 144 P3 TWD 6 DBH
-1.52 TEH TEC 23 COLD 60OUL 114 38 0.30 138 P2 TWD 12 06C
-0.69 TEC TEH 9
HOT 600UL 114 86 0.12 164 P3 TWD 4 DBH
-1.37 TEH TEC 23 COLD 600UL 114 96 0.32 102 P2 TWD 13 VH3
-0.82 TEH TEC 24 COLD 600UL 114 110 0.31 44 P3 TWD 14 DBH
-1.57 TEH TEC 30 COLD 600UL 115 83 0.36 138 P3 TWD 14 DBH
-1.54 TEH TEC 21 COLD 600UL 115 93 0.25 121 P3 TWD 13 DBE
-1.23 TEN TEC 24 COLD 600UL 115 101 0.18 46 23 TWD 7 DBH
+2.15 TEH TEC 23 COLD 600UL 115 137 0.64 36 P2 TWD 26 VHN
-0.98 TEC TEH 5
HOT 600UL 116 64 0.20 104 P3 TWD 9 DBH
-1.13 TEH TEC 19 COLD 600UL 116 92 0.23 119 P2 TWD 10 04H
+0.86 TEH TEC 23 COLD 600UL 116 102 0.41 125 P3 TWD 15 DBH
+0.93 TEh TEC 33 COLD 600UL 117 55 0.66 124 P2 TWD 25 VHI
-0.72 TEH TEC 17 COLD 600UL 117 67 0.42 124 P2 TWD 18 VHI
-0.78 TEH TEC 19 COLD 60OUL 117 95 0.20 55 P3 TWD 10 DBH
+1.98 TEH TEC 24 COLD 60OUL
 
AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -
Unit 2 Component:
S/G 88 Page 11 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryM!(1].qry ROW LINE VOLTS DEG CHN IND
%TW LOCATION EXT EXT CAL # LEG PROBE
- - - -----= --------------= ------
 
== =
--= --= --=
=
-=
=-
 
== = = =-
=-
 
== = = = =-
-==
=-
=:
118 38 0.14 133 P3 TWD 6 DBC
+1.94 TEC TEH 9
NOT 600UL 118 68 0.23 77 P3 TWD 11 DBE
-1.69 TEH TEC 18 COLD 600UL 118 72 0.18 36 P3 TWD 7 DBH
+1.88 TEH TEC 20 COLD 60OUL 0.24 143 P3 TWD 11 DBH
-1.98 TEH TEC 20 COLD EODUL 118 88 0.42 149 P3 TWD 17 DBH
-1.64 TEH TEC 22 COLD 60OUL 118 90 0.20 37 P3 TWD 9 DBE
-1.98 TEH TEC 22 COLD 600UL 119 37 0.11 53 P3 TWD 6 DBC
-2.11 TEC TEH 10 HOT 60OUL 0.31 11 P3 TWD 15 DBC
+2.15 TEC TEH 10 HOT 60OUL 0.18 22 P2 TWD 10 10C
-1.33 TEC TEH 10 HOT 600UL 119 55 0.35 89 P3 TWD 15 DBH
+2.15 TEH TEC 16 COLD 600UL 119 79 0.49 119 P3 TWD 19 DBH
+2.02 TEH TEC 20 COLD 60OUL 119 95 0.49 103 P3 TWD 21 DBH
-1.83 TEH TEC 24 COLD 600UL 119 97 0.39 137 P3 TWD 15 DBH
-1.57 TEH TEC 25 COLD 60OUL 119 99 0.33 126 P3 TWD 16 DBH
-1.93 TEH TEC 24 COLD 60OUL 119 101 0.37 115 P3 TWD 14 DBH
-1.74 TEH TEC 23 COLD 60OUL 119 109 0.47 15 P3 TWD 20 DBH
+1.91 TEH TEC 30 COLD 60OUL 120 38 0.19 148 P3 TWD 10 DBC
-1.82 TEC TEH 10 HOT 600UL 0.22 117 P3 TWD 11 DBC
+2.25 TEC TEH 10 HOT 600UL 120 48 0.30 84 P2 TWD 14 VH2
-0.76 TEH TEC 17 COLD 60OUL 120 66 0.46 107 P3 TWD 19 DBH
-1.32 TEH TEC 18 COLD 60OUL 120 74 0.23 101 P2 TWD 10 10H
-1.19 TEH TEC 20 COLD 60OUL 120 78 0.30 135 P2 TWD 13 VHN
-0.73 TEH TEC 21 COLD 60OUL 120 80 0.27 63 P3 TWD 12 DBH
-1.96 TEH TEC 20 COLD 600UL 120 86 0.24 115 P3 TWD 11 DBH
-1.60 TEH TEC 22 COLD 600UL 0.35 103 P2 TWD 15 10H
+1.25 TEH TEC 22 COLD 60OUL 120 92 0.33 91 P3 TWD 13 DBH
-2.11 TEH TEC 23 COLD 600UL 120 94 0.11 135 P3 TWD 6 DBH
-1.95 TEH TEC 24 COLD 600UL 120 106 0.88 154 P3 TWD 24 DBH
+1.84 TEH TEC 32 COLD 60OUL 120 138 0.50 128 P3 TWD 21 DBH
-1.87 TEC TEH 5
HOT 600UL 121 39 0.41 72 P2 TWD 19 03C
-0.91 TEC TEH 10 HOT 600UL 121 67 0.25 94 P3 TWD 11 DBH
-1.75 TEH TEC 19 COLD 60OUL 121 69 0.30 17 P2 TWD 14 04H
+0.83 TEH TEC 19 COLD 600UL 121 71 0.22 137 P3 TWD 10 DBH
-1.60 TEH TEC 19 COLD 600UL 121 125 0.44 137 P2 TWD 17 10H
+0.73 TEH TEC 28 COLD 600UL 121 137 0.26 153 P3 TWD 13 DBH
-1.85 TEC TEH 5
NOT 60OUL 122 76 0.55 110 P2 TWD 21 VHl
+0.00 TEH TEC 21 COLD 600UL 122 94 0.32 145 P3 TWD 15 DBH
+1.92 TEH TEC 24 COLD 60OUL 122 96 0.46 141 P3 TWD 20 DBH
+1.93 TEH TEC 24 COLD 600UL 122 98 0.61 108 P2 TWD 22 l0H
+1.21 TEH TEC 24 COLD 600UL 0.24 140 P3 TWD 12 DBH
+1.95 TEH TEC 24 COLD 600UL 122 112 0.25 109 P2 TWD 11 10H
-1.16 TEN TEC 30 COLD 600UL 122 114 0.42 77 P2 TWD 17 10H
+0.95 TEH TEC 31 COLD 600UL 0.35 149 P3 TWD 13 DBH
+1.52 TEN TIC 31 COLD 600UL
 
AREVA NP Inc 01/09/08 14:19:37 Customer Name: San Onofre -
Unit 2 Component:
S/G 88 Page 12 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, EVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryM![l.qry ROW LINE VOLTS DEG CHN IND
%TW LOCATION EXT EXT CAL # LEG PROBE 122 124 0.46 128 P3 TWD 20 DBE
+1.84 TEH TEC 28 COLD 600UL 123 65 0.31 117 P3 TWD 14 DBH
-0.35 TEH TEC 18 COLD 600UL 124 64 0.54 107 P2 TWD 22 10H
-1.07 TEH TEC 19 COLD 60OUL 124 88 0.34 56 P3 TWD 13 DBH
+1.98 TEE TEC 23 COLD 600UL 125 91 0.33 140 P3 TWD 13 DBH
+1.87 TEN TEC 23 COLD 600UL 126 86 0.48 134 P3 TWD 18 DBH
+1.98 TEH TEC 23 COLD 60OUL 126 90 0.40 110 P3 TWD 16 DBH
+1.91 TEH TEC 22 COLD 60OUL 126 112 0.55 40 P3 TWD 22 DBH
+1.89 TEH TEC 30 COLD 600UL 127 53 0.60 100 P2 TWD 21 VHI
-0.85 TEH TEC 16 COLD 600UL 127 83 0.33 113 P3 TWD 14 DBH
-1.95 TEH TEC 20 COLD 60OUL 128 60 0.62 115 P2 TWD 22 10H
-1.19 TEH TEC 16 COLD 60OUL 0.40 64 P2 TWD 16 10H
+0.02 TEH TEC 16 COLD 60OUL 128 68 0.30 24 P3 TWD 12 DBH
+1.62 TEH TEC 19 COLD 600UL 129 47 0.77 129 P2 TWD 27 VH3
-0.90 TEH TEC 17 COLD 60OUL 129 63 0.37 100 P2 TWD 17 10H
-0.10 TEH TEC 19 COLD 600UL 129 67 0.49 79 P3 TWD 19 DBH
-2.00 TEH TEC 19 COLD 60OUL 130 74 0.41 66 P2 TWD 17 10H
+0.08 TEH TEC 21 COLD 60OUL 0.69 159 P2 TWD 24 10H
-1.07 TEH TEC 21 COLD 600UL 130 78 0.41 124 P2 TWD 16 VHl
+0.91 TEH TEC 20 COLD 600UL 130 128 0.46 67 P2 TWD 19 VH2
-0.48 TEH TEC 29 COLD 60OUL 131 83 0.20 111 P3 TWD 9
DBH
-1.74 TEH TEC 26 COLD 600UL 131 89 0.65 119 P2 TWD 25 10H
+0.94 TEH TEC 26 COLD 600UL 131 127 0.48 117 P2 TWD 17 03C
+0.82 TEH TEC 51 COLD 600UL 132 94 0.56 69 P2 TWD 22 10H
+0.95 TEH TEC 26 COLD 600UL 133 75 0.45 117 P3 TWD 17 DBH
+2.03 TEH TEC 25 COLD 600UL 133 83 0.51 158 P2 TWD 20 10H
-1.04 TEH TEC 27 COLD 600UL 133 115 0.42 114 P2 TWD 16 10H
+0.88 TEH TEC 28 COLD 600UL 134 66 0.18 113 P3 TWD 8 DBH
+0.98 TEH TEC 25 COLD 600UL 134 68 0.30 130 P2 TWD 13 10H
-0.71 TEH TEC 25 COLD 600UL 134 82 0.16 33 P3 TWD 7 DBH
+2.04 TEH TEC 27 COLD 600UL 134 84 0.78 136 P2 TWD 27 10H
-1.14 TEH TEC 27 COLD 600UL 134 86 1.14 141 P2 TWD 33 10H
-1.02 TEH TEC 27 COLD 600UL 134 100 0.41 154 P2 TWD 17 10H
+0.91 TEH TEC 27 COLD 600UL 135 67 0.08 25 P3 TWD 3 DBH
+2.25 TEH TEC 25 COLD 600UL 135 87 0.78 153 P2 TWD 28 10H
-1.04 TEH TEC 26 COLD 60OUL 135 91 0.41 109 P2 TWD 17 03H
-0.28 TEH TEC 27 COLD 60OUL 135 93 0.36 42 P2 TWD 15 10H
+0.98 TEH TEC 27 COLD 600UL 135 97 0.17 30 P2 TWD 8 10H
+0.92 TEH TEC 26 COLD 600UL 136 74 0.35 123 P2 TWD 15 10H
-1.02 TEH TEC 24 COLD 600UL 136 86 0.31 145 P2 TWD 14 10H
-0.96 TEH TEC 26 COLD 600UL 137 91 0.56 157 P2 TWD 22 10H
-1.08 TEH TEC 26 COLD 60OUL
 
AREVA NP Inc 01/09/08 14:19:37 Customer Name: San Onofre -
Unit 2 Component:
S/G 88 Page 13 of 14 Post U2C15 Inspection Final Report
: MAT, MCI,
: MMI, MVI,
: SAi, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 137 119 0.41 80 P2 TWD 17 01C
-0.95 TEH TEC 29 COLD 60OUL 138 84 0.40 117 P2 TWD 17 VHi
+0.86 TEH TEC 27 COLD 600UL 139 61 0.46 120 P2 TWD 18 VHl
-0.93 TEH TEC 25 COLD 60OUL 139 105 0.56 75 P2 TWD 22 10H
+0.83 TEH TEC 29 COLD 60OUL 140 76 0.18 72 P3 TWD 8 DBH
-2.04 TEH TEC 26 COLD 600UL 140 88 0.25 140 P3 TWD 11 DBH
+1.86 TEH TEC 26 COLD 600UL 141 63 0.11 166 P3 TWD 5 DBC
-2.04 TEH TEC 25 COLD 600UL 0.40 17 P3 TWD 15 DBC
+1.63 TEH TEC 25 COLD 600UL 141 65 0.34 108 P2 TWD 15 08C
+0.77 TEH TEC 25 COLD 60OUL 141 67 0.69 108 P2 TWD 24 VC1
+0.86 TEH TEC 24 COLD 60OUL 141 77 0.25 121 P2 TWD 12 VC1
+0.90 TEH TEC 26 COLD 60OUL 0.30 71 P3 TWD 13 DBC
+1.61 TEH TEC 26 COLD 600UL 141 87 0.18 107 P2 TWD 9 VCt
+0.91 TEH TEC 27 COLD 600UL 142 66 0.44 172 P3 TWD 17 DBC
+1.49 TEH TEC 25 COLD 600UL 142 68 0.25 125 P2 TWD 11 10H
-0.24 TEH TEC 25 COLD 600UL 142 84 0.47 119 P3 TWD 17 DBC
+1.69 TEH TEC 27 COLD 600UL 142 86 0.20 116 P3 TWD 9 DBH
+1.90 TEH TEC 26 COLD 600UL 142 90 0.27 111 P3 TWD 11 DBH
+2.07 TEH TEC 27 COLD 600UL 142 98 0.29 15 P3 TWD 13 DBC
+1.44 TEH TEC 26 COLD 600UL 142 104 0.34 20 P3 TWD 13 DBH
+1.60 TEH TEC 29 COLD 60OUL 142 110 0.54 42 P3 TWD 19 DBH
+1.80 TEH TEC 29 COLD 600UL 143 83 0.49 38 P3 TWD 18 DBC
+1.57 TEH TEC 27 COLD 600UL 143 89 0.27 64 P3 TWD 11 DBH
-1.63 TEH TEC 26 COLD 600UL 143 109 0.23 126 P3 TWD 10 DBH
-1.57 TEH TEC 29 COLD 600UL 0.27 122 P2 TWD 13 VC2
+0.78 TEH TEC 29 COLD 600UL 0.46 73 2
SAT 03H
-0.85 03H 03H 152 HOT 580PP 144 76 0.19 48 P2 TWD 9 04H
-0.08 TEH TEC 26 COLD 600UL 0.38 130 P2 TWD 17 VC2
+0.92 TEN TEC 26 COLD 600UL 144 78 0.29 143 P2 TWD 13 VC2
+0.90 TEH TEC 26 COLD 600UL 0.43 122 P3 TWD 17 DBC
-1.53 TEH TEC 26 COLD 600UL 144 80 0.45 131 P3 TWD 18 DBH
+1.93 TEH TEC 26 COLD 600UL 144 86 0.31 139 P3 TWD 12 DBH
+1.97 TEH TEC 27 COLD 600UL 144 96 0.42 129 P3 TWD 17 DBH
+2.00 TEH TEC 26 COLD 60OUL 0.54 129 P3 TWD 20 DBC
+1.26 TEH TEC 26 COLD 600UL 145 79 0.59 100 P3 TWD 20 DBC
+1.69 TEH TEC 27 COLD 600UL 145 87 0.20 146 P3 TWD 8 DBC
-1.87 TEH TEC 26 COLD 600UL 0.19 34 P3 TWD 8 DBC
+1.81 TEH TEC 26 COLD 600UL 0.41 109 P2 TWD 18 VC1
+1.08 TEH TEC 26 COLD 60OUL 145 89 0.26 91 P3 TWD 10 DBH
-1.75 TEH TEC 27 COLD 600UL 0.34 48 P2 TWD 15 VC1
+0.85 TEh TEC 27 COLD 60OUL 146 82 0.32 151 P3 TWD 13 DBC
+1.69 TEH TEC 27 COLD 60OUL 0.20 56 P2 TWO 9 03H
-0.63 TEH TEC 27 COLD 600UL 146 86 0.17 95 P2 TWD 8 08C
+0.87 TEH TEC 27 COLD 60OUL 0.14 82 P3 TWD 6 DBH
+1.87 TEH TEC 27 COLD 60OUL 0.18 99 P3 TWD 7 DBC
+1.77 TEH TEC 27 COLD 600UL 146 94 0.23 78 P2 TWD 10 02H
+0.87 TEH TEC 27 COLD 600UL 0.58 61 P2 TWD 22 VHI
+1.22 TEH TEC 27 COLD 600UL
 
AREVA NP Inc Customer Name: San Onofre -
Unit 2 01/09/08 14:19:37 Component:
S/G 88 Page 14 of 14 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryM![11.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 147 91 0.47 105 P2 TWD 19 VCl
-0.85 EXT EXT CAL # LEG TEH TEC 27 COLD PROBE 600UL Total Tubes
: 430 Total Records: 531
 
Inspection of Steam Generator Tubes Special Report Appendix 4 Page 1 of 16 Appendix 4 Tube Inspection Summary Steam Generator E-089


AREVA NP InC                                              01/09/08 14:19:36 Customer Name:   San Onofre - Unit 2                     Component: S/G 88        Page 2 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,     0-100%,   PCS QUERY:   QueryMi[l]
AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -
ROW LINE VOLTS     DEG CHN IND %TW LOCATION           EXT EXT   CAL # LEG   PROBE 1    133  0.40    0    P2  TWD 18  04C      -0.17  07C TEC    6    COLD  600UL 6    138  0.15    87  2  SAI    07H      -0.98  07H 07H    156  HOT  580PP 6    168  0.37    130  P2  TWD 18  04H      -0.31  TEC TEH    23    HOT  600UL 7    55    0.32    110  2  SAI    07C      +0.97  07C DBC    109  COLD  5809P 7    137  0.57    27  P1  SCI    TSH      -1.95  TSH TSH    86    HOT  580PP 7    143  0.33    20  P1  SCI    TSH      -4.84  TSH TSH    85    HOT  580PP 8    156  0.57    24  Pl  SCI    TSH      -0.15  TSH TSH    85    HOT  580PP 9  51    0.27    77  2  SAI    03H      -0.32  03H 03H    212  HOT  520ET 10  40    0.23    22  P1  SCI    TSH      -0.08  TSH TSH    76    HOT  580PP 11  147  0.57    22  P1  SCI    TSH      -0.07  TSH TSH    83    HOT  580PP 12  24    0.27    104 2  SAI    06H      -0.13  06H 06H    169  HOT  580PP 13  9    0.34    98  P2  TWD 14  05H      -0.14  TEC TEH    25    HOT  60OUL 13  47    0.33    21  P1  SCI    TSH      -0.02  TSH TSH    80    HOT  580PP 13  55    0.26    69  2  SAI    05H      +0.64  05H 05H    183  HOT  580PP 13  159  0.14    45  P3  TWD 8  DBH      -2.25  TEC TEH    19    HOT  600UL 14  126  0.40    17  P1  SCI    TSH      -0.15  TSH TSH    70    HOT  580PP 14  130  0.45    24  P1  SCI    TSH      -0.06  TSH TSH    74    HOT  58OPP 15  119  0.43    133 P2  TWD 19  07C      -0.96  TEH TEC    49  COLD  600UL 15  141  0.27    23  P1  SCI    TSH      -2.80  TSH TSH    79  HOT  58022 16  140  0.51    17  P1  SCI    TSH      -8.44  TSH TSH    78  HOT  580PP 17  15    0.55    16  2  SAI    TSH      -6.03  TSH TSH    72  HOT  580PP 0.55    13  2  SAI    TSH      -6.32  TSH TSH    72  HOT  58OPP 17  57    0.31    123 2  SAI    01H      +0.75  01H 01H    189  HOT  580PP 0.22    97  2  SAI    06H      +0.58  06H 06H    189  HOT  580P2 17  59    0.42    15  2  SAI    TSH      -1.09  TSH TSH    87  HOT  5802P 18  34    0.32    19  P1  SCI    TSH      +0.05  TSH TSH    49  HOT  5802P 18  44    0.23    113 P3  TWD 10  DBH      -2.00  TEC TEH    13  HOT  60OUL 19  47    0.52    18  P3  TWD 19  DBC      +1.66  TEH TEC    37  COLD  600UL 19  135  0.36    147 P3  TWD 18  DBH      +2.00  TEC TEH    11    HOT  600UL 19  141  0.50    14  2  SAI    TSH      -6.13  TSH TSH    79    HOT  580PP 20  68  0.37    68  P3  TWD 13  DBH      -1.71  TEH TEC    39    COLD  600UL 20  108  0.14    43  P3  TWD 6    DBH      -1.54  TEH TEC    50    COLD  600UL 20  120  0.42    16  P1  SCI    TSH        -0.19  TSH TSH    64    HOT  580PP 21  31  0.48    23  P1  SCI    TSH        -14.04  TSH TSH    52    HOT  580PP 21  61  0.47    17  P3 TWD 17  DBC      +1.98    TEH TEC    38    COLD  600UL 21  63  0.35    105 2    SAI    07C      -0.85  07C 07C    113  COLD  58OPP 21  67  0.32    79  P3  TWD 12  DBH      +2.00  TEH TEC    38    COLD  600UL 0.34    141  P2  TWD 13 VSM        +0.76  TEH TEC    38    COLD  600UL 21  113  0.52    17  2  SAI    TSH      -2.37  TSH TSH    65    HOT  58OPP 21  127  0.18    107  2  SAI    04H      +0.77  04N 04H    150  HOT  580P2 21  129  0.31      52  P1  SCI    TSH      -0.09  TSH TSH    65    HOT  5802?
Unit 2 Component:
S/G 89 Page 2 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2]
ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE


AREVA NP Inc                                              01/09/08 14:19:36 Customer Name:  San Onofre -    Unit 2                    Component: S/G 88        Page 3 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, NVI, SAI, SCI, SVI,      0-100%,  PCS QUERY: QueryMI[1].qry ROW LINE VOLTS  DEG CHN IND %TW LOCATION            EXT EXT    CAL  LEG  PROBE 22  52  0.31  60  2    SAI      03H      -0.70  03H 03H    212  HOT  520ET 23  109  0.47  113  P2  TWD 20  VSM      +1.02  TEH  TEC  50    COLD 60OUL 0.51  15  2    SAI      TSH      -0.79  TSH  TSH  64    HOT  580PP 0.58  15  2    SAI      TSH      -0.57  TSH  TSH  64    HOT  580PP 0.26  14  2    SAI      TSH      -1.15  TSH  TSH  64    HOT  580PP 24  14  0.11  23  P2  TWD 7    VSM      +0.88  TEC TEH    22    HOT  60OUL 24  64  0.95  13  2    SAI      TSH      -0.81  TSH TSH    89    HOT  580PP 24  156  0.38  101 P2    TWD 17  03H      +0.88  TEC TEH    20    HOT  60OUL 24  160  0.20  85  2    SAI      06H      -0.06  06H 06H    155  HOT  580?P 25  117  0.39  22  P1  SOI      TSR      -0.16  TSH TSH    65    HOT  580PP 25  133  0.53  25  P1  SCI      TSH      -0.13  TSH TSH    75    HOT  580PP 0.70  22  P1  SCI      TSH      -0.14  TSH TSH    75    HOT  580PP 26  146  0.15  16  P3  TWD 5    DBH      +0.74  TEC TEH    16    HOT  60OUL 27  61  0.92  15  2    SAI      TSH      -1.20  TSH TSH    89    HOT  580PP 0.87  14  2    SAI      TSH      -4.41  TSH TSH    89    HOT  580PP 27  159  0.23  99  2    SAI      02H      +0.03  02H 02H    155  HOT  580PP 0.49  97  2    SAI      03H      +0.87  03H 03H    155  HOT  580PP 0.28  50  2    SAI      02H      +0.79  02H 02H    155  HOT  580PP 28  120  0.52  18  2    SAI    TSH      -6.66  TSH TSR    64    HOT  580PP 30  8    0.24  96  2    SAI    03H      +0.85    03H 03H  169  HOT  580PP 30  38  0.51  18  P1    SCI    TSH      -0.08  TSH TSH    102  HOT  580PP 30  52  0.22  73  2    SAI    TSH      +0.66  TSH TSH    81    HOT  580PP 31  11  0.29  97  P3  TWD 11    DBH      +1.80  TEC TEH    25    HOT  600UL 31  65  0.54  10  P3  TWD 19    DBC      +2.00  TEH TEC    38    COLD  600UL 31  67  0.61  21  P1    SCI    TSH      -0.06  TSH TSH    89    HOT  580PP 31  69  0.57  11  2    SAI    TSH      +0.00    TSH TSH    93  HOT  5802P 31  107  0.80  15  2    SAI    TSH      -1.05    TSH TSH    64  HOT  580PP 31  123  0.28  98  2    SAI      05H      +0.66    05H 05H    150  HOT  580PP 31  165 0.76  23    2    SAI      05H      -0.34    05H 05H    159  HOT  58OPP 0.60  14    2    SAI      05H      +0.39    05H 05H    159  HOT  5802P 0.39  16    2    SAI      05H      +0.54    05H 05H    159  HOT  580PP 32  4  0.31  131  P2  TWD 16  01C      -0.92  TEC TEH    26  HOT  60OUL 32  112 0.81  16    2    SAI      TSH      -1.63  TSH TSH    65  HOT  580PP 0.69  15    2    SAI      TSH      -2.08  TSH TSH    65  HOT  580PP 32  122 0.74    15  2    SAI      TSH      -0.88  TSH TSH    71  HOT  58022 33  37  0.42    24  P1  SCI      TSH      -0.10  TSH TSH    48  HOT  5802?
=========================================
33  105 0.50    6    P3  TWD 21  DBC      +1.53  TEC TEH    36  HOT  600UL 0.31    144 P3    TWD 14  DBH      -1.69  TEC TEH    36  HOT  60OUL 0.20    82  P3  TWD 10  DBC      -1.59  TEC TEH    36  HOT  60OUL 34  108 0.66    19  2    SAI      TSH      -0.77  TSH TSH    64  HOT  580PP 35  27  0.34    87  P2  TWD 14  VSR      +0.72  TEC TEH    17  HOT  600UL 0.37    77    22  TWD 15  VSM      -0.74  TEC TEH    17  HOT  600UL 35  69  0.47  15  2    SAT      TSH      -1.07  TSH TSH    93  HOT  580PP 35  71  0.53  100  P3  TWD 19  DBC      -1.90  TEH TEC    38  COLD  600UL 36  70  0.75  14    2  SAI      TSH      -1.59  TSH TSH    93  HOT  580PP 0.51  12    2  SAI      TSH      -3.11  TSH TSH    93  HOT  580PP 0.70  14    2  SAI      TSH      -3.93  TSH TSH    93  HOT  580PP 37  47  0.47  107  P2  TWD 20  VSM      +0.88  TEH TEC    317  COLD  600TUL


AREVA NP Inc                                              01/09/08 14:19:36 Customer Name:  San Onofre - Unit 2                       Component: S/G 88        Page 4 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,      0-100%,  PCS QUERY:    QueryMl[l].qry ROW LINE VOLTS    DEG CHN IND %TW LOCA TION            EXT EXT    CAL # LEG  PROBE 37  61    0.36  154  P2  TWD 14  VSM      +0.93    TEH TEC    38    COLD 60OUL 37  71    0.66  15  2   SAI     TSH        -2.58  TSH TSH    93    HOT   580PP 37  103  0.54  23    P3  TWD 22  DBH        -2.10  TEC TEH    35    HOT   60OUL 38  28    0.23  90    2   SAI     0H        +0.33   01H 01H    169  HOT   580PP 0.44  68    2   SAI     05H       -0.67  05H 05H   169  HOT   580PP 38  110    0.79  13    2   SAI     TSH        -1.44  TSH TSH    64    HOT   580PP 0.55  12    2   SAI     TSH        -0.65  TSH TSH    64    HOT   58OPP 39  43    0.46  10    P3  TWD 17  DBC        +1.33  TEC TEH    13    HOT   60OUL 39  71    0.35  128  P3  TWD 13  DBC        -1.55  TEH TEC    38    COLD  60OUL 40  58    0.41  15    2   SAI     TSH        -3.72  TSH TSH    88    HOT   58OPP 40  162    0.31  120  2   SAI     06H       +0.25  06H 06H   158  HOT   580PP 41  7      0.40  137  P2  TWD 16  VSM        -0.77  TEC TEH    25    HOT   60OUL 41  39    0.71  12    P1  SCI    TSH        -1.42  TSH TSH    48    HOT   580PP 41  69    0.69  11    2   SAI     TSH        -2.14  TSH TSH    93    HOT   58OPP 41  73    0.41  110 P2  TWD 17  VSM        +0.93  TEH TEC    39    COLD  60OUL 0.23  34    P3  TWD 9  DBC        +1.43  TEH TEC    39    COLD  60OUL 41  101    0.17  85    P3  TWD 6  DBH        -1.79  TEC TEH    28    HOT   60OUL 0.22  53    P3  TWD 8  DBC        +1.91  TEC TEH    28    HOT   60OUL 42  14    0.16  140 2   SAI     DBH        -0.81  DBH DBH    130  COLD  560P2 0.20  122 2   SAI     DBH        -0.11  DBH DBH    130  COLD  560P2 42  74    0.36  86  P3  TWD 13  DBC        +1.32  TEH TEC    39    COLD  600UL 0.32  34  P3 TWD 12  DBC       -1.68  TEH TEC    39    COLD  600UL 42  106    0.71  126 P2   TWD 30  VSM        -0.98  TEC TEH    35    HOT  60OUL 0.46  14  2   SAI     TSH        -1.18  TSH TSH    64    HOT   580PP 42  158    0.21  152 P3  TWD 11  DBH        +1.72  TEC TEH    19    HOT   60OUL 43 19     0.59  95  P2  TWD 25  02H        +0.87  TEC TEH    22    HOT   60OUL 43  51    0.93  105 P2  TWD 31  VSM        +0.88  TEH TEC    37    COLD  600UL 43  57    0.37  57  P3 TWD 13  DBH       +1.68  STH TEC   41    COLD 60OUL 0.22  46  P3  TWD 8  DBC        +1.72  STH TEC    41    COLD  60OUL 43  73    0.27  82  P3  TWD 11  DBC        -1.89  TEH TEC    38    COLD  600UL 0.65  15  2  SAI    TSH       -3.90  TSH TSH   93    HOT   58OPP 43  101  0.34  58  P3 TWD 12  DBC       -1.68  TEC TEH   27    HOT   600UL 0.55  176 P3   TWD 19  DBC        +1.66  TEC TEH   27     HOT   600UL 43  125  0.57  106 P2  TWD 23  VSM        -0.84  TEH TEC    50    COLD  60OUL 44  58    0.22  21  P2  TWD 10  VSM        -1.08  TEH TEC    39    COLD  600UL 0.47  109 P2  TWD 19  VSM        +0.86    TEH TEC  39    COLD  600UL 44  108  0.27  81  P2  TWD 13 VSM        +0.87    TEC TEH  36    HOT   60OUL 0.34  132 P2  TWD 16 VSM        -0.77    TEC TEH  36    HOT   60OUL 44   124  0.38  107 P2  TWD 17  VSM        -0.95    TEH TEC    50    COLD  60OUL 45  73    0.38  126 P3   TWD 13  DBC        -1.61    STH TEC   41    COLD 60OUL 45  145  0.24  80  P2  TWD 12  VSM        +0.88    TEC TEH    15    HOT   60OUL 46  6    0.26  141 P3   TWD 13  DBC       +1.63    TEC TEH  26    HOT  60OUL 0.41  39  P2 TWD 19  VSM       -0.75    TEC TEH   26    HOT   60OUL 46  148  0.24  122 2    SAI    01H      -0.16    0H 01H    155  HOT  58OPP 47  109  0.38  90    P2 TWD 14 VSM        -0.02    STH TEC   41    COLD  60OUL 0.45  107  P2 TWD 16 VSM        +0.88    STH TEC    41    COLD  600UL 47  111  0.35  11  2    SAI    TSH        -3.12  TSH TSH    64    HOT  58OPP
======= =
2 122 0.30 95 2
SAI 01H
+0.74 01H 01H 170 HOT 58OPP 3
127 0.41 113 2 SAI 07C
+0.01 07C 07C 108 COLD 58OPP 5
119 0.53 89 2
SAI 07H
-0.50 07H 07H 169 HOT 580PP 0.33 86 2
SAI 07H
-0.30 07H 07H 169 HOT 580PP 0.33 85 2
SAI 07C
+0.61 07C 07C 108 COLD 580PP 6
58 0.33 16 P1 SCI TSH
-6.31 TSH TSH 107 HOT 580PP 8
36 0.35 73 2
SAI 05H  
-0.71 05H 05H 148 HOT 580PP 8
122 0.27 72 2
SAI 07H
-0.62 07H 07H 169 HOT 580PP 9
65 0.32 90 2
SAI 07H
+0.73 07H DBH 193 HOT 58OPP 9
117 0.26 93 2
SAI 05H
+0.91 05H 05H 170 HOT 580PP 10 44 0.31 75 2
SAI 05H
-0.83 05H 05H 145 HOT 58OPP 0.23 77 2
SAI 05H
+0.54 05H 05H 145 HOT 580PP 11 19 0.30 135 2 SAI 06H  
+0.22 06H 06H 145 HOT 580PP 0.23 104 2 SAI 04H
-0.19 04H 04H 145 HOT 58OPP 11 55 0.37 101 2 SAI 05H
+0.94 05H 05H 157 HOT 580PP 11 65 0.30 67 2
SAI 01H
+0.54 01H 01H 203 HOT 58OPP 11 119 0.31 55 2
SAI 04H
-0.25 04H 04H 164 HOT 580PP 11 121 0.50 22 P1 SCI TSH
-10.71 TSH TSH 82 HOT 580PP 11 131 0.72 14 P1 SCI TSH
-13.59 TSH TSH 52 HOT 58OPP 12 114 0.40 130 2 SAI 06H
-0.16 06H 06H 215 HOT 520ET 12 128 0.22 121 2 SAI 01H
+0.58 01H 01H 168 HOT 58OPP 0.34 114 2 SAI 04H
+0.50 04H 04H 168 HOT 58OPP 13 37 0.20 33 P3 TWD 16 DBC  
-0.09 TEC TEH 27 HOT 600UL 13 123 0.58 103 P2 TWD 22 07H
+0.62 TEH TEC 31 COLD 600UL 14 18 0.17 83 2
SAI 05H
+0.88 05H 05H 148 HOT 580PP 14 58 0.41 125 2 SAI 04H
+1.07 04H 04H 157 HOT 58OPP 15 131 0.43 19 P1 SCI TSH
-0.10 TSH TSH 52 HOT 58OPP 15 141 0.54 21 P1 SCI TSH
-0.08 TSH TSH 99 HOT 580PP 16 52 0.18 100 P3 TWD 11 DBH  
-2.12 TEH TEC 34 COLD 600UL 16 56 0.12 96 2
SAI 06H
-1.39 06H 06H 157 HOT 58OPP 16 60 0.39 19 P1 SCI TSH  
-0.09 TSH TSH 66 HOT 58OPP 17 27 0.13 27 P3 TWD 11 DBC  
+1.54 TEC TEH 19 HOT 600UL 17 43 0.13 20 P3 TWD 11 DBH
-1.90 TEC TEH 27 HOT 600UL 17 49 0.13 110 P1 SCI TSH
+0.08 TSH TSH 71 HOT 58OPP 18 26 0.20 98 2
SAI 06H
-0.15 06H 06H 148 HOT 580PP 18 34 0.29 13 2
SAI TSH
-5.71 TSH TSH 85 HOT 580PP 0.48 16 2
SAI TSH
-5.26 TSH TSH 85 HOT 580PP 18 44 0.13 147 P3 TWD 11 DBH
-1.81 TEC TEH 27 HOT 600UL 18 122 0.36 110 P3 TWD 15 DBE
-1.89 TEH TEC 29 COLD 600UL 18 144 0.44 11 P3 TWD 19 DBh
+1.15 TEC TEN 14 HOT 600UL 19 109 0.23 124 P3 TWD 10 DBC  
+1.33 TEH TEC 29 COLD 600UL 19 173 0.21 157 P2 TWD 12 VSM  
+0.81 TEC TEH 22 HOT 60OUL 20 18 0.71 125 P2 TWD 26 VSm
-0.16 TEC TEH 16 HOT 600UL


AREVA NP Inc                                               01/09/08 14:19:36 Customer Name: San Onofre - Unit 2                       Component: S/G 88        Page 5 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,     0-100%,   PCS QUERY:   QueryMl[l].qry ROW LINE VOLTS   DEG CHN IND %TW LOCATION             EXT EXT   CAL # LEG   PROBE 0.84  19    2  SAI      TSH      -0.87    TS1 TSH    64    HOT  58OPP 47  125  0.36  77    P2  TWD 16  VSM      +0.78    TEH TEC    50    COLD  600UL 47  143  0.15  78    2  SAI      01H      -0.03    01H 01H    155  HOT  580PP 48  76    0.58  90    P3  TWD 19  DBC      -1.75    TEC TEH    27    HOT  600UL 0.18  7    P3  TWD 6    DBH      +1.47    TEC TEN    27    HOT  60OUL 48  114  0.29  139  P3  TWD 14  DBH      -1.59    TEH TEC    49    COLD  60OUL 48  124  0.28  25    P1  SCI      TSH      -0.10    TSH TSH    65    HOT  580PP 48  134  0.57  19  P1  SCI      TSN      -0.07    TSH TSH    78    HOT  580PP 49  47    0.14  105 2    SAI      08C      -1.17    08C 08C    113  COLD  580PP 49  69    0.41  113 P2  TWD 16  08C      -1.22    TEH TEC    38    COLD  600UL 49  75    0.41  88    P3  TWD 17  DBH      -1.78    TEN TEC    36    COLD  600UL 50  8    0.28  131 P2  TWD 14  VSM      +0.77    TEC TEH    26    HOT  600UL 50  98    0.52  70    P2  TWD 22  VSM      -0.92    TEC TEH    28    HOT  60OUL 50  102  0.40  15  2  SAI      13W      -0.42    TSN TSN    127  NOT  580PP 50  106  0.41  13  2  SAI      TSH      -0.07    TSH TSH    127  HOT  580PP 50  110  0.23  60  P2  TWD 12  08H      +0.87    TEC TEN    31    HOT  60OUL 50  148  0.38  101 2    SAI      08H      +0.81    08H 08H    155  HOT  58OPP 50  164  0.40  115 P2  TWD 18  VSM      +0.82    TEC TEH    20    HOT  600UL 51  55    0.29  114 P1  SCI      TSH      +0.03    TSH TSH    87    HOT  58OPP 51  57    0.36  94  P1  SCI      TSH      +0.06    TSH TSH    87    HOT  580PP 51  81    0.85  121  P3  TWD  26  DBC      -1.61    TEC  TEH  27    HOT  600UL 0.46  169  P3  TWD  16  DBH      +1.43    TEC  TEH  27    HOT  600UL 0.58  142  P3  TWD  19  DBH      -1.55    TEC  TEH  27    HOT  60OUL 0.79  133  P3  TWD  25  DBC      +1.85    TEC  TEH  27    HOT  600UL 51  117  0.69  21  P1  SCI      TSH      -0.10    TSH TSH    64    HOT  58OPP 51  155  0.21  108 2    SAI      04H      +0.75    04H 04H  155  HOT  58OPP 51  163  0.39  41  P2  TWD 17  VH3      +0.90    TEC TEH    20    HOT  600UL 52  72    0.17  105  2  SAI      TSH      +0.23    TSH TSH    94    HOT  580PP 52  76    0.37  60  P3  TWD 13  DBC          1.55  TEC TEN    27    HOT    60OUL 52  112  0.79  15  2  SAI      TSH          1.87  TSH TSH  65    HOT    580PP 0.51  12  2  SAI      TSH          2.57  TSH TSH  65    HOT    58OPP 0.67  15  2  SAI      TSH          3.37  TSH TSH  65    HOT    580PP 0.45  13  2  SAI      TSH          3.67  TSH TSH    65  HOT    580PP 53  57  0.28  98  P1  MCI      TSH      + 0.15    1S3 TSH  88    HOT    580PP 53  113  0.68  14  2  SAI      TSH      - 5.31    TSH TSH    64  HOT    580PP 0.43  12  2  SAT      TSH      - 3.74    TSH TSH    64  HOT    58OPP 0.74  14  2  SAi      ISE      - 1.74    TSH TSH    64  HOT    58OPP 54  8    0.39  124  P2 TWD 18    01H      + 0.06    TEC TEN    26  HOT    600UL 0.18  123  P2 TWD 10    01H      - 1.06  TEC TEN    26  HOT    600UL 54  38  0.49  20  P1  SCI    TSH        - 0.02  TSH TSH    49  HOT    580PP 54  60  0.17  112 2    SAI    TSH        +0.15    TSH TSH    90  HOT    580PP 54  72  0.20  79    P!  SCI      TSH      + 0.06  TSH TSH    93  HOT    580PP 54  76  0.41  48    P3 TWD  14  DBC      - 1.65  TEC TEE    28    HOT  60OUL 54  92  0.10  44    P3  TWD 4    DBH        1.84  TEC TEH    27    HOT  600UL 54  96  0.63  80    P3  TWD 20  DBH        1.77  STH TEC    41    COLD  60OUL
AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -
Unit 2 Component:
S/G 89 Page 3 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMi[2].qry ROW LINE VOLTS DEG CHN IND  
%TW LOCATION EXT EXT CAL # LEG PROBE


AREVA NP Inc                                                          01/09/08 14:19:36 Customer Name:  San Onofre - Unit 2                                  Component: S/G 88                      Page 6 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,      0-100%,  PCS QUERY:  QueryMl[l].qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION                      EXT EXT    CAL # LEG      PROBE 55  81    0.43    126  P3 TWD 15  DBH      -1.59              TEC TEH    27    HOT       600UL 55  91    0.61    128  P3  TWD 20  DBH      -1.67             TEC TEH    27    HOT      600UL 55  95    0.58    171  P3  TWD 19  DBC      +1.68              TEC TEH    27    HOT      60OUL 56  78    0.21    111 P3  TWD 8    DBH      -1.47              TEC TEH   28    HOT       600UL 56  80    0.92    141  P3  TWD 27  DBC      -2.00              TEC TEH    27    HOT       600UL 0.59    95  P3  TWD 20  DBH      -1.52              TEC TEH    27    HOT      600UL 0.27   11  P3  TWD 12  DBH      +1.75              TEC TEH   27    HOT       600UL 56  112  0.27    31  P3  TWD 12  DBH      -2.07              TEC TEH    31    HOT      60OUL 56  126  0.39    21  P!  SCI     TSH       -0.17              TSH TSH   65    ROT      580PP 56  154  0.53    10  2  SAI      TSH      -7.34              TSH TSH    85    HOT       580PP 57  73    0.12    103 21  SCI     TSH       +0.09              TSH TSH   94    HOT       580PP 57  91    0.18    142 P3  TWD 8    DBC      -1.66              STH TEC    42    COLD      600UL 57  97    0.73    19  P3  TWD 23  DBH      +1.72              TEC TEH   28    HOT       60OUL 57  105  0.41    20  2  SAI      TSH       -2.35              TSH TSH   59    HOT       580PP 57  109  0.37    78  P2  TWD 18  03H      -1.21              TEC TEH    31    HOT        600UL 57  161  0.41    114 2   SAI     06H       -0.41              06H 06H 155      HOT       580PP 57  167  0.52    147 P2  TWD 23  02C      +0.89              T.C TEH 23      HOT       600UL 58  70    0.65    19  2   SAI     TSH       -2.27              TSH TSH   93    HOT       580PP 58  96    0.38    147 P3   TWD 15  DBH       -1.80              TEC TEH    27    HOT        600UL 58  100  0.40    57  P2  TWD 18  VSM      -0.80              TEC TEH    28    HOT        600UL 59  23    0.48    100 P2  TWD 19  VH3      -0.92              TEC TEH    21    HOT        600UL 59  25    0.41    155 P2  TWD 18  VH3      +0.84              TEC TEH   18    HOT        60OUL 0.35    138 P2  TWD 15  VH3      -0.82              TEC TEH    18    HOT        600UL 59  83    0.56    18  2  SAI      TSH       -1.40              TSH TSH   50   HOT       58OPP 0.30    19  2  SAI      TSH      -0.87              TSH TSH    50    HOT        580PP 59  95    0.28    22  P3 TWD 10  DBC      +1.58              TEC TEH   28    HOT       60OUL 59  161  0.41    80  P2  TWD 17  VH3      -0.90              TEC TEH    19    HOT        600UL 60  86    0.23    88  2  SAI      VC3      +0.84              VC3 VC3    118  COLD      560P2 0.40    91  P2  TWD 16  VC3      +0.84              STH TEC   42    COLD       600UL 0.49    12  P3 TWD 17  DBH      +1.91              STH TEC   42    COLD       600UL 60  106  0.31    25  P1 SCI     TSH       -0.00              TSH TSH   59    HOT       580PP 61  27    0.28    20  P2  TWD 12  VH3      -0.70              TEC TEH    18    HOT       60OUL 61  45  0.20    132 P3  TWD 9    DBC      +0.75              TEC TEH    13  HOT       600UL 61  85  0.27    160 P3  TWD 11    DBC      -1.58              TEC TEN  27    HOT       600UL 0.56    169 P3  TWD 20    DBC      +1.78              TEC TEH  27   HOT       600UL 61  87  0.32    154 23  TWD 11    DBC      -1.98               TEC TEH  27    HOT       60OUL 1.11    23  P3 TWD 31    DBH      +1.75              TEC TEH  27    HOT        600UL 61  125  0.27    143 P2 TWD 12  VC3        -0.10              TEC TEH    32  HOT        600UL 62  80  0.22    73  P1   SCI    TSH       +0.03              TSH TSR    51  HOT       580PP 62  114  0.58    18  2    SAT    TSH        -2.04              TSH TSH    60  HOT        58022 64  80  0.53    117  P3 TWD 18    DBH       +1.21              TEC TEH    27  HOT        60OUL 64  106  5.92    183  4  PCS      SBH      +5.04  TO+13.33    STH SBH    101  HOT        500SP 64  120  0.47    26  P1  SCI      TSH      -0.03              TSH TSH    59  HOT        580P2 65  81  0.22    108  P3 TWD 8    DBC      -1.22              TEC TEH    28    HOT      600UL 0.14    125  P3 TWD 6    DBC       +2.00              TEC TEH    28    HOT      600UL
======-----------------------=---------------=====---==-------=-=-=-===-======-=------==-=----
20 108 0.17 122 P3 TWD 10 DBC
+1.77 TEH TEC 30 COLD 600UL 20 120 0.49 120 2 SAI 04H
+0.69 04H 04H 215 HOT 520ET 0.42 132 2 SAI 04H
-0.26 04H 04H 215 HOT 520ET 21 67 0.49 98 P2 TWD 22 VSM
+0.78 TEH TEC 36 COLD 600UL 22 2
0.33 129 P2 TWD 23 VSM
-0.91 TEC TEH 11 HOT 60OUL 22 50 5.84 186 4 PCS SBH
+3.47 TO+10.13 STH SBH 128 HOT 500SP 22 118 0.43 126 P2 TWD 21 07H
+1.07 TEH TEC 30 COLD 600UL 23 23 0.27 50 P2 TWD 13 07H
+0.60 TEC TEH 20 HOT 60OUL 23 115 0.38 137 P2 TWD 16 VSM
+0.75 TEH TEC 29 COLD 600UL 23 137 0.32 22 P1 SCI TSH  
-0.14 TSH TSH 42 HOT 580PP 24 18 0.27 109 P2 TWD 12 VSM
-0.92 TEC TEH 16 HOT 600UL 24 50 0.23 103 P1 SCI TSH  
+0.12 TSH TSH 72 HOT 58OPP 24 130 0.19 120 P1 SCI TSH
+0.08 TSH TSH 50 HOT 58OPP 24 154 0.18 49 P2 TWD 11 VSM
+0.25 TEC TEH 17 HOT 60OUL 25 49 0.16 95 P1 SCI TSH  
+0.09 TSH TSH 71 HOT 580PP 25 51 0.32 100 2 SAI 07C
-0.60 07C 07C 109 COLD 58OPP 25 149 0.26 73 2
SAI 06H  
-0.38 06H 06H 169 HOT 580PP 28 54 0.37 111 2 SAI TSH
+0.35 TSH TSH 71 HOT 58OPP 28 122 0.19 107 P1 MCI TSH
+0.12 TSH TSH 81 HOT 58OPP 29 47 0.30 102 2 SAI 07H
+0.61 07H 07H 161 HOT 580PP 29 59 0.32 17 2
SAI TSH  
-3.59 TSH TSH 65 HOT 580PP 29 113 0.20 53 P3 TWD 12 DBH  
-1.77 TEH TEC 30 COLD 600UL 30 70 0.35 136 P3 TWD 17 DBC
-1.46 TEH TEC 36 COLD 600UL 30 106 0.17 149 P3 TWD 10 DBC
-1.90 TEH TEC 30 COLD 600UL 30 134 0.47 20 P1 SCI TSH  
-6.96 TSH TSH 50 HOT 58OPP 31 45 0.36 51 P3 TWD 14 DBH
+1.64 TEC TEH 31 HOT 600UL 31 71 0.60 79 P3 TWD 27 DBH
-2.04 TEH TEC 36 COLD 600UL 0.26 129 P3 TWD 13 DBC
+1.79 TEH TEC 36 COLD 600UL 0.25 142 P3 TWD 12 DBC
-1.83 TEH TEC 36 COLD 600UL 32 48 0.45 23 P1 SCI TSH  
-0.09 TSH TSH 72 HOT 58OPP 33 67 0.26 83 2
SAI 04H
+0.50 04H 04H 205 HOT 58OPP 0.17 114 2 SAI TSH
+0.47 TSH TSH 64 HOT 58OPP 0.21 100 2 SAI TSH
+0.62 TSH TSH 64 HOT 580PP 34 112 0.28 83 2
SAT 04H
-0.34 04H 04H 159 HOT 58OPP 35 49 0.14 116 2 SAI TSH
+0.27 TSH TSH 72 HOT 580PP 35 111 0.72 16 2
SAI TSH
-0.98 TSH TSH 83 HOT 580PP 0.21 46 2
SAI 04H
-0.29 04H 04H 159 HOT 580PP 36 104 0.19 31 P3 TWD 11 DBC
-2.10 TEH TEC 30 COLD 600UL 36 114 0.35 112 P2 TWD 15 02H
+0.90 TEH TEC 29 COLD 60OUL 36 128 0.34 104 P1 MCI TSH  
+0.05 TSH TSH 75 HOT 58OPP 37 101 0.30 103 P3 TWD 17 DBC
+1.75 TEH TEC 24 COLD 600UL 0.26 136 P3 TWD 15 DBH  
+1.75 TEH TEC 24 COLD 60OUL 37 103 0.52 78 P3 TWD 19 DBH
-1.87 TEH TEC 29 COLD 600UL 0.45 39 P3 TWD 17 DBC  
+1.74 TEH TEC 29 COLD 600UL


AREVA NP Inc                                             01/09/08 14:19:36 Customer Name: San Onofre - Unit   2                   Component: S/G 88        Page 7 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAT, SCI, SVI,     0-100%,   PCS QUERY:   QueryMl[l].qry ROW LINE VOLTS   DEG CHN IND %TW LOCATION           EXT EXT   CAL # LEG PROBE 65  87    0.14  78  P1  SCI    TSH      +0.06   TSH TSH    51    HOT 580PP 65  91    0.21  26  P2 TWD 8  VH3      +0.70  TEC TEH    27    HOT 600UL 65  111  0.41  21  P1  SCI    TSH      -0.15  TSH  TSH  59    HOT 58OPP 0.75  17  2  SAI    TSH      -1.11  TSH  TSH  59    HOT  580PP TEC TEN   34    ROT  600UL 66  48    0.41  130 P2  TWD 18  VC3      -0.85  TEC TEH  34    HOT  600UL 0.31  136 P2  TWD 15  VSM      +0.90  TEC  TEH  34    HOT 600UL 0.56  103 92  TWD 23  VSM      -0.90 67  81    0.62  91  P3 TWD 21  DBC       -1.35  TEC TEH    27    HOT  600UL 67  87    0.30  28  P3 TWD 11  DBH      +1.60   TEC TEH    27    HOT 600UL 0.36  148 P3  TWD 13  DBE      -1.36  TEC TEH    27    HOT 600UL 67  111  0.16  103  P1 SCI     TSH       +0.16  TSH TSH   60    HOT 58OPP 67  165  0.78  119  P2  TWD 30  VH3      -0.86  TEC TEH    23    HOT 600UL 68  112  0.55  24  P1 MCI    TSH       -6.12  TSH TSH   127  HOT 580PP 0.30  18  PT  SCI     TSH       -9.88  TSH TSH   127  HOT 580PP 68  146  0.53  73  P2  TWD 21  VC3      -0.84   TEC TEH    15    HOT  600UL 68  164  0.57  102 P2   TWD 23  VH3      +0.63  TEC TEH    20    HOT  600UL 69  85    0.24  132  P3 TWD DBC       -1.73  TEC TEH    27    HOT  60OUL 69  87    0.41  134  P3 TWD 15  DBH      +2.00  STH TEC   42    COLD 600UL 69  119  0.51  21  P1  SCI    TSH      -0.03  TSH TSH    59    HOT  58OPP 0.37  20  P1  SCI    TSH      -0.02  TSH TSH    59    HOT  58OPP 70  82    0.31  159  P3 TWD 11  DBC       +1.88  TEC TEH    28    HOT  600UL 70  86    0.34  51  P3 TWD 13  DBH       -1.42   TEC TEH    27    HOT  60OUL 0.50  15  2  SAI    TSH       -2.15  TSH TSH   50   HOT 580PP 0.46    11  2  SAI    TSH      -1.84  TSH TSH    50    HOT 580PP 70  104  0.29  109 2    SAI    TSH       +0.17  TSH TSH   60    HOT 58OPP 71  13    0.55  123  P2 TWD 21  VH3      -0.79  TEC TEH    21   HOT 60OUL 72  70    0.31  87  P2 TWD 15  VC3      -0.93    TEC TEH  38    HOT 600UL 72  90    0.56    126 P2 TWD 22  VSM       +0.74    TEC TEH  27    HOT 600UL 0.27  29  P2 TWD 11  VSM       -0.98    TEC TEH  27    HOT 600UL 72  100  0.33    132  P1  SCI    TSH      +0.05    TSH TSH    50  HOT  580PP 73  17  0.59    98  P2 TWD 22  VH3      -0.82    TEC TEH  21    HOT  600UL 73  75    0.33    135 P2  TWD 15  VC3      +0.60    TEC TEH    38  HOT  60OUL 73  133  0.41    110 P2 TWD 18  VH3      +0.81    TEC TEH    12  HOT  600UL 73  161  0.46    128  P2 TWD 19 VH3      +1.21    TEC TEH    20  HOT  600UL 74  148  0.22    83  P2  TWD 10 VH3        -0.92  TEC TEH    16  HOT  600UL 75  95  0.63    28  P1  SCI    TSH        -0.19  TSH TSH    51  HOT  580PP 75  99  0.24    97  P1  SCI    TSH       +0.08  TSH TSH   51    HOT 58OPP 75  141  0.33    129  P2  TWD 14 VH3        -0.93  TEC TEH    16   HOT 600UL 75  157  0.28    116  P2  TWD 13 VH3        -0.79  TEC TEH    20    HOT  600UL 76  18  0.22    96  2   SAI    06H        +0.62  06H 06H    169  HOT 580PP 76  84  0.34    121 P2   TWD 14 VH3        +0.76  TEC TEH    27    HOT  600UL 0.35    55  P2 TWD 15 VH3        -0.84  TEC TEH    27    HOT  600UL 76  86  0.24    23  P3  TWD 9  DBC        +2.25  TEC TEH    28    HOT  600UL 77  31  0.36    131 P2   TWD 14 VSM       +0.88   TEC TEH    17    HOT 600UL 0.24    105 22  TWD 11 VSM        +0.33  TEC TEH    17    HOT 60OUL
AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -
Unit 2 Component:
S/G 89 Page 4 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[21.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE
--------------=-------------------=-====--------------==--===-------------==-==---------------=
38 4
0.20 45 P2 TWD 16 01C
+0.06 TEC TEN 11 HOT 60OUL 0.23 36 P2 TWD 18 02C
-0.92 TEC TEN 11 HOT 600UL 38 8
0.23 93 2
SAI 06H
+0.70 06H 06H 148 HOT 58OPP 38 20 0.19 130 P3 TWD 14 DBH
+0.56 TEC TEN 19 HOT 600UL 38 104 0.25 68 P3 TWD 11 DBC
-1.76 TEH TEC 29 COLD 60OUL 39 45 0.18 107 P1 MCI TSH
+0.04 TSH TSH 80 HOT 580PP 39 101 0.28 106 P3 TWO 11 DBC
-2.00 TEN TEC 23 COLD 60OUL 0.24 55 P3 TWD 10 DBC  
+1.94 TEN TEC 23 COLD 60OUL 39 115 0.27 14 P3 TWD 15 DEN
+1.94 TEN TEC 30 COLD 60OUL 39 131 0.60 15 2
SAI TSH
-7.50 TSH TSH 52 HOT 58OPP 0.47 14 2
SAI TSH
-8.54 TSH TSH 52 HOT 580PP 39 133 0.24 86 P1 SCI TSH  
+0.03 TSH TSH 52 HOT 58OPP 0.73 21 2
SAI TSH
-7.28 TSH TSH 52 HOT 58OPP 40 46 0.25 101 P1 SCI TSH  
+0.05 TSH TSH 80 HOT 580PP 40 60 0.33 110 2 SAI TSH
+0.31 TSH TSH 65 HOT 58OPP 40 74 0.43 123 P3 TWD 20 DBC
-1.64 STH TEC 38 COLD 600UL 40 136 0.51 25 P1 SCI TSH  
-8.81 TSH TSH 99 HOT 58OPP 41 57 0.34 27 P3 TWD 13 DBH
+1.84 TEN TEC 33 COLD 600UL 41 63 0.48 58 P2 TWD 20 02H
+0.93 TEN TEC 35 COLD 60OUL 41 73 0.27 49 P3 TWD 14 DBC  
-1.29 TEN TEC 36 COLD 60OUL 41 75 0.67 106 P3 TWD 22 DBC
+1.83 TEN TEC 35 COLD 60OUL 0.13 113 P3 TWD 6 DBC
-1.71 TEN TEC 35 COLD 60OUL 41 101 0.77 110 P3 TWD 25 DBC  
+2.10 TEN TEC 23 COLD 600UL 41 113 0.24 25 P3 TWD 14 DBH  
-1.86 TEN TEC 30 COLD 60OUL 41 119 0.42 71 P3 TWD 22 DBH
+1.88 TEN TEC 30 COLD 60OUL 41 131 0.57 18 P1 SCI TSH  
-0.16 TSH TSH 50 HOT 58OPP 41 143 0.24 50 P2 TWD 14 VSM
+0.78 TEC TEH 13 HOT 60OUL 42 38 0.91 27 P1 SCI TSH  
-0.12 TSH TSH 80 HOT 58OPP 42 168 0.54 156 P2 TWD 23 VSM
+0.90 TEC TEN 21 HOT 600UL 42 170 0.67 117 P2 TWD 27 VSM
-0.35 TEC TEN 22 HOT 60OUL 44 18 0.16 50 P2 TWD 7 VSM  
+0.55 TEC TEN 16 HOT 600UL 0.32 128 P2 TWD 14 VSM  
-0.92 TEC TEN 16 HOT 60OUL 44 74 0.67 59 P3 TWD 23 DBC
-2.14 TEN TEC 35 COLD 60OUL 0.23 67 P3 TWD 10 DBC
+2.00 TEN TEC 35 COLD 600UL 44 104 0.23 136 P3 TWD 13 DBH
+2.02 TEN TEC 30 COLD 60OUL 0.57 80 P2 TWD 25 VSM
+0.74 TEN TEC 30 COLD 600UL 0.13 12 P2 TWD 7 VSN
-1.04 TEN TEC 30 COLD 600UL 0.21 74 P3 TWD 13 DBE
-1.67 TEN TEC 30 COLD 600UL 44 112 0.53 142 P2 TWD 20 VSM
-0.80 TEN TEC 29 COLD 60OUL 45 63 0.26 78 2
SAI TSH  
+0.19 TSH TSH 63 HOT 580PP 0.76 20 2
SAT TSH
-3.16 TSH TSH 63 HOT 580PP 0.53 21 2
SAI TSH
-2.39 TSH TSH 63 HOT 580PP 45 103 0.90 130 P2 TWD 29 VSE
+0.86 TEH TEC 29 COLD 600UL 0.39 131 P2 TWD 16 VSM
-0.80 TEN TEC 29 COLD 60OUL 0.26 144 P2 TWD 12 VSM
+0.00 TEN TEC 29 COLD 600UL 45 145 0.25 76 P2 TWD 15 VSM  
-0.88 TEC TEN 13 HOT 600UL 46 48 0.13 103 P!
SCI TSH
+0.14 TSH TSH 71 HOT 580PP


AREVA NP Inc                                             01/09/08 14:19:36 Customer Name: San Onofre - Unit 2                       Component: S/G 88          Page 8 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,     0-100%,   PCS QUERY:   QueryMl[ll.qry ROW LINE VOLTS   DEG CHN IND %TW LOCATION             EXT EXT    CAL # LEG  PROBE 77  33  0.41    42  P2  TWD 18  VSM      +0.93  TEC TEH    18    HOT  600UL 77  39  0.21    135 P3    TWD 11  DBC      +1.57  TEC TEH    14    HOT  600UL 77  85  0.68    15  2    SAI    TSH      -1.92  TSH TSH    50    HOT  580PP 77  161  0.57    134 P2    TWD 22  VH3      -0.84  TEC TEH    20    HOT  60OUL TEC TEN    22    NOT  600UL 78  22  0.56    84  P2  TWD 24  VC3      -0.92  TEC TEH    22    HOT  600UL 0.53    37  P3  TWD 23  DBC      -1.80 TSN TSH    94    HOT  580PP 78  74    0.32  20  P1  SCI    TSH      -0.06 78  96    0.20  114  P1  SCI    TSH      +0.11  TSN TSH    51    HOT  58OPP 78  98    0.38  25  P1  SCI    TSH      -0.10  TSH TSH    51    HOT  58OPP 78  102  0.53  28  P1  SCI    TSH      +0.00  TSH TSH    59    HOT  580PP 78  120  0.39  29  P1  SCI    TSH      -6.00  TSH TSH    60    HOT  580PP 78  138  0.31  41  P3  TWD 14  DBC      +1.47  TEC TEH    12    HOT  60OUL 78  142  0.39  128  P2  TWD 16  VH3      +0.87  TEC TEH    16    HOT  600UL 78  144  0.66  47  P3  TWD 21  DBC      +1.65  TEC TEH    16    HOT  600UL 78  148  0.49  140  P2  TWD 20  08C      -0.92  TEC TEH    16    HOT  600UL 78  154  0.45  128  P2  TWD 19  VC3      +0.82  TEC TEH    20    HOT  60OUL 0.25  162  P2  TWD 12  VC3      -0.80  TEC TEH    20    HOT  600UL 79  15    0.41  19  P3  TWD 16  DBH      +1.45  TEC TEH    21    HOT    60OUL 79  19    0.23  40  P3  TWD 10  DBC      +1.84  TEC TEH    21    HOT    600UL 79  23    0.28  79  P3  TWD 12  DBC      +1.80  TEC TEH    21    HOT    600UL 79  81    0.17  22  P1    SCI    TSH      -0.05  TSH TSH    50    HOT    580PP 79  97    0.37  120 P1    SCI    TSH      +0.03  TSH TSH    50    HOT    580PP 79  143  0.18  111 P3    TWD 11  DBC      -1.50  TEC TEH    15    HOT    600UL 80  84    0.24  16  P1    SCI    TSH      -0.08  TSH TSH    50    HOT    58OPP 80  112  0.32  115 P2    TWD 17 VSM      -0.84  TEC TEH    31    HOT    60OUL 81  23    0.37  54    P3  TWD 15 DBC      +1.55  TEC TEH    7    HOT    600UL 81  93  0.61  15  2    SAI    TSH      -2.60  TSH TSH    114  HOT    580PP 600UL 81  151  0,35  129  P2  TWD 16 VH3      +0.57  TEC TEH    11  HOT    600UL 0,12  29    P2  TWD 5  VH3      -0.21  TEC TEH    11  HOT 82  54  0,74  96    P2  TWD 25 VH3      -0.70  TEH TEC    16  COLID  600UL 0,13  170  P2  TWD 6  VH3      +0.91  TEH TEC    16  COLID  600UL 82  160  0,25    91  P3  TWD 13 DBH      +2.02  TEC TEN    11  HOT    600UL 83  49  0,32    104 2    SAI    02H      +2.02    02H 02H    173  HOT  580PP 83  87  0,45  25    PI  SCI    TSH      -0.12  TSH TSH    118  HOT  580PP TEN TEC    23  COLD  600UL 83  99  0,12    123 P3    TWD 5  DBH      -1.75 TEH TEC    17    COLD  600UL 84  48  0,64    92    P2  TWD 24 09C      -1.50 85  43  0,56    131  P2  TWD 19 VH2      -1.12    TEC TEH    9    HOT  600UL 86  32  0,17    164  P3  TWD 7  DBC      +1.75    TEC TEH    7    HOT  600UL 86  54  0,24    119  P2  TWD 11 VH2      -0.77    TEH TEC    16    COLD  600UL
AREVA N? Inc Customer Name: San Onofre -
                                              +--0-66 86  130  0.34    94    P2  TWD 17 VC2                TEC TEH    6    HOT  600UL TEC TEN    10    NOT  600Ut 87  37  0,36    131 P2    TWD 17 7H2        -0.94  TEC TEN    10    HOT    600UL 0.38    133 P2    TWD 18 VH2        -1.06 87  63  0,42    116 P3    TWD 17  DBH      -0.25  TEH TEC    19    COLD  600UL
Unit 2 1/9/2008 2:18i16 PM Component: S/G 89 Page 5 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2).qry ROW LTNE VOLTS DEG CHN IND %TW LOCATION


AREVA NP Inc                                                    01/09/08 14:19:36 Customer Name:    San Onofre -  Unit 2                        Component: S/G 88                    Page 9 of 14 Post U2C15 Inspection Final Report MAT, MCI, MNT, NVI, SAT, SCI, EVI, 0-100%,      PCS QUERY:    QueryMlil] .gry ROW LINE VOLTS      DEG CHN IND %TW LOCATION                EXT EXT CAL # LEG        PROBE
============  
:====::-=---=----==== -- := ======== -=====-===*===:
88    60    0.20    91  2  SAI      01H    +2.27          01H 01H    178  HOT      580PP 88    154  0.53    51  P2  TWD 22  VH2    -0.83          TEC TEH    12    HOT      600UL 89    35    0.43    94  P2  TWD 16  VH2    -0.93          TEC TEH    7    HOT      60OUL 89    37    0.56    129 P2  TWD 19  VH2    -0.96          TEC TEH    9    HOT      600UL 89    51    0.32    73  P2  TWD 15  VH3    +0.80          TEH TEC    17    COLD    60OUL 0.42    22  P3  TWD 17  DBH    -1.85          TEH TEC    17    COLD    60OUL 89  157  0.18    145 P3  TWD 10  DBH    +1.90          TEC TEH    11    HOT      600UL 90  42    0.24    104 2    SAI      VC2    +0.12          VC2 09C    114  COLD    560P2 0.26    118 2    SAI      08H    +0.75          08H 08H    173  HOT      580PP 90  78    0.27  17  P1  SCI      TSH    -0.11          TSH TSH    120  HOT      580PP 91  55    0.35  63  P2  TWD 16  VH2    +0.84          TEH TEC    17    COLD    60OUL 91  125    0.36  125  P2  TWD 16  VH2    -0.86          TEH TEC    29    COLD    60OUL 92  26    0.64  86  P2  TWD 25  VH2    -0.79          TEC TEH    8    HOT      600UL 92  36    0.56    87  P2  TWD 23  VH2    -0.89          TEC TEH    10    HOT      600UL 92  56    0.23  102 P2  TWD 12  09H    -0.64          TEH TEC    17    COLD    600UL 93  65    0.35  122 P2  TWD 16  VH2    -0.70          TEH TEC    19    COLD    600UL 93  153    0.37  68  P2  TWD 17  03C    +0.95          TEC TEH    12    HOT      60OUL 0.47  66  P2  TWD 20  05C    -0.89          TEC TEH    12    HOT      600UL 0.19  84  P2  TWD 10  VC3    -0.96          TEC TEH    12    HOT      600UL 94  24    0.41  131  P2  TWD 15  VH2    +1.12          TEC TEH    7    HOT      60OUL 94  40    0.38  119  P2  TWD 15  VH2    +1.12          TEC TEH    9    HOT      600UL 94  48    0.24  106  2  SAI      01H    +0.21            01H 01H  172  HOT      580PP 95  71    0.30  19  P1  SCI      TSH    -0.08          TSH TSH    111  HOT      580PP 97  35    0.49  145  P2  TWD 18  VH2    -0.98          TEC TEH    7    HOT      600UL 98  44    0.25  27  P3  TWD 13  DBH    -2.20          TEC TEH    10    HOT      600UL 0.41  70  P2  TWD 18  VSM    +0.75          TEC TEH    10  HOT      600UL 98  94    0.22  89  P1  SCI      TSH    +0.00            TSH TSH    114  HOT      580PP 99  49    0.27    18  P3  TWD 11  DBH    -2.00            TEH TEC    17  COLD      600UL TEC TEN    6    NOT      600UL 99  131    0.23    150 P2  TWD 12  VH3    +0.67            TEC TEH    6    HOT      600UL 0.41    102 P2  TWD 19  VH3    -1.01 TEC TEH    11  HOT      600UL 99  149    0.59    114  P2 TWD 24  VH2    +0.00 100 102    0.19    21  P1  SCI    TSH    -0.07          TSH TSH    54  HOT      58OPP 100 118    0.39    32  P1  SCI      TSH    +0.00          TSH TSH    57  HOT      58OPP 101 29      0.45    137  P2  TWD 20  VH2    +0.77          TEC TEH    8    HOT      600UL 101 77    0.49    95  P3  TWD 18  DBH    +1.15          TEH TEC    21  COLD      600UL 101 147    0.56    147  P2  TWD 24  VSE    -0.74          TEC TEH    5    HOT      600UL 102 26    0.33    112  P2  TWD 16  06H    +0.87          TEC TEH    8    HOT      600UL 104 40    0.35    49  P3  TWD 17  DBC    +2.03          TEC TEH    10    HOT      600UL 105 99    0.40    132 P2  TWD 17  03H    +0.74          TEH TEC    23    COLD    60OUL 106 30    0.34    122 P2  TWD 14  06H    +0.81          TEC TEH    7    HOT      600UL 106 76    0.36    54  P2  TWD 15  02H    -0.20          TEH TEC    21  COLD    600UL 0.21    149 P2  TWO 10  VC2    -0.78          TEN TEC    20  COLD    600UL 106  78    0.26    149 P2  TWD 11  VC2    +0.89          TEH TEC    20  COLD    60OUL


AREVA NP Inc                                                01/09/08 14:19:36 Customer Name:    San Onofre - Unit 2                      Component: S/G 88          Page 10 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,        0-100%,  PCS QUERY:    QueryMl[13.qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION            EXT EXT    CAL # LEG  PROBE 107 29    0.55    9    P3  TWD 23  DBC        +1.29   TEC TEH    8    HOT  600UL 107 33    0.22    107  P2 TWD 12  09H        -0.37  TEC TEH    8    HOT  60OUL 107 75      0.34  66    P2 TWD 14  09C        -0.29   TEH TEC    7    COLD  60OUL 107  95    0.31  126  P2 TWD 13  VH2        +0.82  TEH TEC   23    COLD 60OUL 107  97    0.28   135  P1  SCI    TSH        +0.03  TSH TSH    114  HOT   580PP 0.29  115  P2 TWD 12  VH3        -0.88  TEH TEC    22    COLD  600UL 107  125  0.46  111 P2   TWD 19  VN2        -0.69  TEN TEC   29    COLD  60OUL 0.22   101 23    TWD 9  DBH        -1.42  TEH TEC    29   COLD  600UL 108  36    0.32   79    P3 TWD 15  DBC        -1.80  TEC TEH   10    HOT   60OUL 108  142  0.16  151 P3   TWD 8  DBE        +1.66  TEC TEH   6    HOT   600UL 109  77    0.26  132 P2   TWD 11  VH2        +0.82  TEH TEC   21    COLD 600UL 1i0 52    0.19  97    P3 TWD DBH       -1.33  TEH TEC   16    COLD   600UL 110 96    0.23  91    P3  TWD 9  DBH        +2.24  TEH TEC   23    COLD   600UL 110 138    0.37  116 P2   TWD 18  VC3        -0.90  TEC TEH   6    HOT   600UL I11 33    0.15  11    P3  TWD 8  DBH        +1.75  TEC TEN    8    HOT   600UL 111 37    0.29  20   P3  TWD 14  DBH        +1.85  TEC TEH     10  HOT   60OUL 111 67    0.46  115 2    SAI    02H        +1.06  02H 02H    178  HOT   580PP 11  81    0.23  142  P3  TWD 10  DBH        +2.24  TEN TEC    21    COLD  600UL il1 101    0.21  56    P3  TWD 8  DBH        -0.75  TEH TEC   23    COLD   600UL 112  92    0.35  32    P2  TWD 15  VH2        -0.70  TEH TEC     23  COLD   600UL 112  116  0.15  47   P2 TWD 7  VH3        -0.85  TEH TEC     30  COLD   600UL 112  144  0.86  158  P3  TWD 30  DBH        +2.13   TEC TEH    5    HOT   600UL 113  37    0.36  135  P2 TWD 14  VH2        -0.93  TEC TEN    9    HOT   600UL 0.17  138  P3  TWD 8  DBH        +1.84  TEC TEH     9    HOT   600UL 113  39   0.42  109  P3  TWD 17  DBH        +1.98  TEC TEH     9    HOT   600UL 113  41    0.47  94    P2  TWD 17  VH2        -0.68  TEC TEH    9    HOT   600UL 113  47    0.25  35    P3  TWD 11  DBH        -1.34  TEH TEC     17  COLD   600UL 113 87    0.16    144 P3  TWD 6  DBH        -1.52  TEH TEC    23    COLD  60OUL 114 38    0.30    138 P2  TWD 12  06C        -0.69  TEC TEH    9    HOT   600UL 114  86  0.12    164 P3  TWD 4  DBH        -1.37  TEH TEC    23    COLD  600UL 114 96    0.32    102 P2   TWD 13  VH3        -0.82    TEH TEC   24    COLD 600UL 114  110  0.31    44    P3 TWD 14   DBH      -1.57    TEH TEC     30  COLD 600UL 115  83  0.36    138  P3 TWD 14  DBH      -1.54    TEH TEC     21  COLD 600UL 115  93  0.25    121  P3 TWD  13  DBE        -1.23  TEN TEC    24    COLD  600UL 115  101  0.18    46    23  TWD 7  DBH      +2.15    TEH TEC    23  COLD  600UL 115 137  0.64    36    P2  TWD 26 VHN        -0.98  TEC TEH    5    HOT  600UL 116 64    0.20   104  P3  TWD 9  DBH        -1.13  TEH TEC    19  COLD  600UL 116 92    0.23    119  P2 TWD 10  04H        +0.86  TEH TEC    23  COLD  600UL 116 102  0.41    125  P3  TWD 15 DBH        +0.93  TEh TEC     33  COLD  600UL 117 55    0.66    124 P2   TWD 25  VHI        -0.72  TEH TEC     17  COLD  600UL 117  67  0.42    124 P2   TWD 18  VHI        -0.78  TEH TEC    19  COLD  60OUL 117  95  0.20    55  P3  TWD 10  DBH        +1.98  TEH TEC    24  COLD  60OUL
=== = = = = = = -
46 52 0.36 134 P2 TWD 15 VSM
-0.88 0.28 163 P2 TWD 12 VSM
+0.80 46 104 0.91 114 P2 TWD 29 VSM
-0.78 0.54 139 P2 TWD 21 VSM
+0.78 0.75 134 P2 TWD 26 VSM
+0.00 46 126 0.41 98 2
SAI 03H
-0.29 46 128 0.41 136 P2 TWD 17 VSM
-0.89 46 134 0.47 91 2
SAI 06H
+0.16 EXT EXT CAL # LEG PROBE TEN TEC 33 COLD 600UL TEH TEC 33 COLD 600UL TEH TEC 29 COLD 600UL TEN TEC 29 COLD 600UL TEH TEC 29 COLD 600UL 03H 03K 215 NOT 520ET TEH TEC 31 COLD 600UL 06H 06H 169 HOT 58OPP 46 156 0.66 115 P2 TWD 28 VSM
-0.87 TEC TEH 18 HOT 60OUL 0.13 152 P2 TWD 8 VSM
+0.77 TEC TEH 18 HOT 600UL 46 162 0.27 63 P2 TWD 15 VSM
+0.89 TEC TEH 22 HOT 60OUL 46 170 0.22 37 P3 TWD 13 DBC
+1.52 TEC TEH 22 HOT 600UL 47 29 0.32 16 P3 TWD 22 DBH
-1.78 TEC TEH 23 HOT 600UL 47 33 0.36 48 P3 TWD 23 DBH
+1.82 TEC TEH 23 HOT 600UL 47 53 0.23 93 P2 TWD 13 VSM
+0.83 STH TEC 38 COLD 600UL 47 117 0.30 51 P3 TWD 17 DBH  
+1.93 TEH TEC 30 COLD 60OUL 47 121 0.21 159 P2 TWD 12 VSM
-0.86 TEH TEC 30 COLD 600UL 48 6
0.39 78 P2 TWD 25 08C
-1.72 TEC TEH 11 HOT 600UL 48 8
0.25 115 P2 TWD 12 02C
+0.89 TEC TEH 12 HOT 600UL 48 12 0.35 86 2
SAI 04H
+0.61 04H 04H 148 HOT 580PP 48 34 0.20 27 P2 TWD 9 VSM
-0.60 TEC TEH 24 HOT 600UL 48 52 0.15 131 P1 SCI TSH
+0.12 TSH TSH 71 HOT 580PP 48 64 0.43 14 2
SAI TSH
-2.18 TSH TSH 63 HOT 58OPP 0.37 13 2
SAI TSH
-1.43 TSH TSH 63 HOT 580PP 48 66 1.50 154 P2 TWD 38 VSM
-0.88 TEH TEC 35 COLD 600UL 48 100 0.63 24 P3 TWD 22 DBC
+1.90 TEH TEC 21 COLD 60OUL 48 118 0.47 40 P2 TWD 19 04H
-1.10 TEH TEC 29 COLD 600UL 48 130 0.36 18 P1 SCI TSH
-0.13 TSH TSH 50 HOT 580PP 48 158 0.55 167 P2 TWD 26 VSM
-0'.74 TEC TEH 17 HOT 600UL 0.09 160 P2 TWD 6 VSM
+0.97 TEC TEH 17 HOT 600UL 49 39 0.22 135 P2 TWD 10 VSM
-0.80 TEC TEH 28 HOT 600UL 49 51 0.15 66 P1 MCI TSH
+0.07 TSH TSH 71 HOT 58OPP 49 53 0.61 129 P2 TWD 23 08C
-1.51 TEH TEC 33 COLD 600UL 0.17 136 Pl SCI TSH
+0.09 TSH TSH 71 HOT 580PP 49 57 0.31 102 2 SAI 08H
+1.54 08H 08H 205 HOT 58OPP 49 65 0.31 135 P2 TWD 14 VSM
-0.71 TEH TEC 35 COLD 600UL 49 75 0.36 134 P3 TWD 14 DBC
-1.85 TEH TEC 35 COLD 600UL 49 103 0.41 153 P2 TWD 17 VSM
-0.80 TEH TEC 29 COLD 60OUL 49 145 0.54 49 159 0.58 0.27 0.12 50 16 0.15 50 44 0.20 102 P2 TWD 26 08H
-1.60 TEC TEH 133 P2 TWD 26 VSM
+0.76 TEC TEH 40 P2 TWD 15 VSM
+0.19 TEC TEH 92 P2 TWD 8 VSM
-1.05 TEC TEH
: 48. P2 TWD 7 08H
+1.23 TEC TEH 114 P2 TWD 15 VSM
-0.82 TEC TEH 13 HOT 600UL 18 NOT 600UL 18 HOT 600UL 18 HOT 60OUL 16 HOT 60OUL 27 HOT 600UL


AREVA NP Inc                                                                        01/09/08 14:19:36 Customer Name:         San Onofre - Unit 2                                         Component: S/G 88                      Page 11 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,                 0-100%,     PCS QUERY:     QueryM!(1].qry ROW LINE VOLTS           DEG CHN IND %TW LOCATION                             EXT EXT     CAL # LEG     PROBE
AREVA NP inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -
- - - - - ---= - -- -- - -- - -- -- -= - --== =
Unit 2 Component: S/G 89 Page 6 of 16 Post U2C15 Inspection Final Report
                                          - --            = - -=
: MAI, MCI,
                                                  - -= - -=    =- -= ==- =
: MMI, MVI,
                                                                          -=--
: SAI, SCI,
                                                                            =-    -- -=-  --= = =
: SVI, 0-100%,
                                                                                      -- --==    -- =- =- -== =: -- - ---
PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE
118    38    0.14        133  P3    TWD 6    DBC        +1.94              TEC TEH    9      NOT    600UL 118 68        0.23        77    P3    TWD 11    DBE        -1.69              TEH TEC    18      COLD  600UL 118 72        0.18        36 P3      TWD 7    DBH        +1.88              TEH TEC    20      COLD  60OUL 0.24        143 P3      TWD 11    DBH        -1.98              TEH TEC    20      COLD  EODUL 118 88        0.42        149 P3      TWD 17    DBH        -1.64              TEH TEC    22      COLD  60OUL 118 90        0.20        37    P3    TWD 9    DBE        -1.98              TEH TEC    22      COLD  600UL 119 37        0.11        53    P3    TWD 6    DBC        -2.11              TEC TEH    10      HOT  60OUL 0.31        11    P3  TWD 15    DBC        +2.15              TEC TEH    10      HOT  60OUL 0.18        22    P2    TWD 10    10C        -1.33              TEC TEH    10      HOT  600UL 119 55        0.35        89    P3  TWD 15    DBH        +2.15              TEH TEC    16      COLD  600UL 119 79        0.49      119    P3  TWD 19    DBH          +2.02              TEH TEC    20      COLD  60OUL 119    95    0.49      103    P3  TWD 21    DBH          -1.83              TEH TEC    24      COLD  600UL 119    97    0.39      137    P3  TWD 15    DBH          -1.57              TEH TEC    25      COLD  60OUL 119    99    0.33      126    P3  TWD 16    DBH          -1.93              TEH TEC    24      COLD  60OUL 119    101    0.37      115    P3  TWD 14    DBH          -1.74              TEH TEC    23      COLD  60OUL 119    109    0.47        15    P3  TWD 20    DBH          +1.91              TEH TEC    30      COLD  60OUL 120    38    0.19      148    P3  TWD 10    DBC          -1.82              TEC TEH    10      HOT  600UL 0.22      117    P3  TWD 11    DBC          +2.25              TEC TEH    10      HOT  600UL 120 48        0.30        84    P2  TWD 14    VH2          -0.76              TEH TEC    17      COLD  60OUL 120 66        0.46        107 P3    TWD 19    DBH          -1.32              TEH TEC    18      COLD  60OUL 120 74        0.23        101 P2    TWD 10    10H          -1.19              TEH TEC    20      COLD  60OUL 120 78        0.30        135 P2    TWD 13    VHN          -0.73              TEH TEC    21      COLD  60OUL 120 80        0.27        63    P3    TWD 12  DBH          -1.96              TEH TEC    20      COLD  600UL 120 86        0.24        115 P3    TWD 11    DBH          -1.60              TEH TEC    22      COLD  600UL 0.35        103 P2      TWD 15  10H          +1.25              TEH TEC    22      COLD  60OUL 120 92        0.33        91    P3    TWD 13  DBH          -2.11              TEH TEC    23      COLD  600UL 120    94    0.11        135  P3    TWD 6    DBH          -1.95              TEH TEC    24      COLD  600UL 120    106    0.88        154  P3    TWD 24  DBH          +1.84              TEH TEC    32      COLD  60OUL 120    138    0.50        128  P3    TWD 21  DBH          -1.87              TEC TEH    5      HOT    600UL 121 39        0.41        72    P2    TWD 19  03C          -0.91              TEC TEH    10      HOT    600UL 121 67        0.25        94    P3    TWD 11  DBH          -1.75              TEH TEC    19      COLD  60OUL 121 69        0.30        17    P2    TWD 14  04H          +0.83              TEH TEC    19      COLD  600UL 121 71        0.22        137 P3      TWD 10  DBH          -1.60              TEH TEC    19      COLD  600UL 121    125  0.44        137 P2      TWD 17    10H        +0.73              TEH TEC    28      COLD  600UL 121    137  0.26        153    P3  TWD 13    DBH        -1.85              TEC TEH      5      NOT    60OUL 122 76      0.55        110 P2      TWD 21  VHl          +0.00              TEH TEC    21      COLD  600UL 122 94      0.32        145    P3  TWD 15    DBH        +1.92              TEH TEC    24      COLD  60OUL 122 96      0.46        141    P3  TWD 20    DBH        +1.93              TEH TEC    24      COLD  600UL 122 98      0.61        108    P2  TWD 22    l0H          +1.21              TEH TEC      24    COLD  600UL 0.24        140    P3  TWD 12    DBH          +1.95              TEH TEC      24    COLD  600UL 122 112      0.25        109    P2  TWD 11    10H          -1.16              TEN TEC      30    COLD  600UL 122 114      0.42        77    P2  TWD 17    10H          +0.95              TEH TEC      31    COLD  600UL 0.35        149    P3  TWD 13    DBH          +1.52              TEN TIC      31    COLD    600UL
= =  
= = =  


AREVA NP Inc                                            01/09/08 14:19:37 Customer Name:  San Onofre - Unit  2                  Component: S/G 88        Page 12 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, EVI, SAI, SCI, SVI,    0-100%,  PCS QUERY:  QueryM![l.qry ROW LINE VOLTS  DEG CHN IND %TW LOCATION          EXT EXT    CAL # LEG  PROBE 122 124  0.46  128  P3  TWD 20  DBE      +1.84  TEH TEC    28    COLD 600UL 123 65    0.31  117  P3  TWD 14  DBH      -0.35  TEH TEC    18    COLD 600UL 124 64    0.54  107 P2  TWD 22  10H      -1.07  TEH TEC    19    COLD 60OUL 124 88    0.34  56  P3  TWD 13  DBH      +1.98  TEE TEC    23    COLD 600UL 125 91    0.33  140 P3  TWD 13  DBH      +1.87  TEN TEC    23    COLD 600UL 126 86    0.48  134 P3  TWD 18  DBH      +1.98  TEH TEC    23    COLD 60OUL 126 90    0.40  110 P3  TWD 16  DBH      +1.91  TEH TEC    22    COLD 60OUL 126  112  0.55  40  P3  TWD 22  DBH      +1.89  TEH TEC    30    COLD 600UL 127 53    0.60  100 P2  TWD 21  VHI      -0.85  TEH TEC    16    COLD 600UL 127 83    0.33  113 P3  TWD 14  DBH      -1.95  TEH TEC    20    COLD 60OUL 128  60  0.62  115 P2  TWD 22  10H      -1.19  TEH TEC    16    COLD 60OUL 0.40  64  P2  TWD 16  10H      +0.02  TEH TEC    16    COLD 60OUL 128 68    0.30  24  P3  TWD 12  DBH      +1.62  TEH TEC    19    COLD 600UL 129 47    0.77  129 P2  TWD 27  VH3      -0.90  TEH TEC    17    COLD 60OUL 129 63    0.37  100 P2  TWD 17  10H      -0.10  TEH TEC    19    COLD 600UL 129 67    0.49  79  P3  TWD 19  DBH      -2.00  TEH TEC    19    COLD 60OUL 130 74    0.41  66  P2  TWD 17  10H      +0.08  TEH TEC    21    COLD 60OUL 0.69  159 P2  TWD 24  10H      -1.07  TEH TEC    21    COLD 600UL 130 78    0.41  124 P2  TWD 16  VHl      +0.91  TEH TEC    20    COLD 600UL 130 128    0.46  67  P2  TWD  19 VH2      -0.48  TEH TEC    29    COLD 60OUL 131  83    0.20  111 P3  TWD  9  DBH      -1.74  TEH TEC    26    COLD 600UL 131 89    0.65  119 P2  TWD 25  10H      +0.94  TEH TEC    26    COLD 600UL 131  127  0.48  117  P2  TWD 17  03C      +0.82  TEH TEC    51    COLD 600UL 132  94    0.56  69  P2  TWD 22  10H      +0.95  TEH TEC    26    COLD 600UL 133 75    0.45  117  P3  TWD 17  DBH      +2.03  TEH TEC    25    COLD 600UL 133 83    0.51  158  P2  TWD 20  10H      -1.04  TEH TEC    27    COLD  600UL 133 115  0.42  114  P2  TWD 16  10H      +0.88  TEH TEC    28    COLD  600UL 134 66    0.18  113  P3  TWD 8  DBH      +0.98  TEH TEC    25    COLD  600UL 134 68    0.30  130  P2  TWD 13  10H      -0.71    TEH TEC  25    COLD  600UL 134 82    0.16  33  P3  TWD 7  DBH      +2.04    TEH TEC  27    COLD  600UL 134 84    0.78  136 P2  TWD 27  10H      -1.14    TEH TEC  27    COLD  600UL 134 86    1.14  141 P2  TWD 33  10H      -1.02    TEH TEC  27    COLD  600UL 134 100  0.41  154 P2  TWD 17  10H      +0.91    TEH TEC    27  COLD  600UL 135 67    0.08  25  P3  TWD 3  DBH        +2.25  TEH TEC    25  COLD  600UL 135 87    0.78  153  P2  TWD 28 10H        -1.04  TEH TEC    26  COLD  60OUL 135 91    0.41  109  P2  TWD 17 03H        -0.28  TEH TEC    27  COLD  60OUL 135 93    0.36  42  P2  TWD 15 10H        +0.98  TEH TEC    27  COLD  600UL 135 97    0.17  30  P2  TWD 8  10H        +0.92  TEH TEC    26  COLD  600UL 136 74    0.35  123  P2  TWD 15 10H        -1.02  TEH TEC    24  COLD  600UL 136 86    0.31  145  P2  TWD 14 10H        -0.96  TEH TEC    26  COLD  600UL 137 91    0.56  157  P2  TWD 22  10H      -1.08  TEH TEC    26  COLD  60OUL
====== = ----------  


AREVA NP Inc                                            01/09/08 14:19:37 Customer Name:  San Onofre - Unit  2                    Component: S/G 88        Page 13 of 14 Post U2C15 Inspection Final Report MAT, MCI, MMI, MVI, SAi, SCI, SVI,    0-100%,  PCS QUERY:  QueryMl[l].qry ROW LINE VOLTS    DEG CHN  IND %TW LOCATION          EXT EXT    CAL # LEG  PROBE 137  119  0.41  80  P2  TWD 17  01C      -0.95  TEH TEC    29    COLD  60OUL 138 84    0.40  117 P2  TWD 17  VHi      +0.86  TEH TEC    27    COLD  600UL 139 61    0.46  120 P2  TWD 18  VHl      -0.93  TEH TEC    25    COLD  60OUL 139 105    0.56  75  P2  TWD 22  10H      +0.83  TEH TEC    29    COLD  60OUL 140 76    0.18  72  P3  TWD 8  DBH      -2.04  TEH TEC    26    COLD  600UL 140 88    0.25  140 P3  TWD 11  DBH      +1.86  TEH TEC    26    COLD  600UL 141 63    0.11  166 P3  TWD 5  DBC      -2.04  TEH TEC    25    COLD  600UL 0.40  17  P3  TWD 15  DBC      +1.63  TEH TEC    25    COLD  600UL 141 65    0.34  108 P2  TWD 15  08C      +0.77  TEH TEC    25    COLD  60OUL 141  67    0.69  108 P2  TWD 24  VC1      +0.86  TEH TEC    24    COLD  60OUL 141 77    0.25  121  P2  TWD 12  VC1      +0.90  TEH TEC    26    COLD  60OUL 0.30  71  P3  TWD 13  DBC      +1.61  TEH TEC    26    COLD  600UL 141 87    0.18  107  P2  TWD 9  VCt      +0.91  TEH TEC    27    COLD  600UL 142 66    0.44  172  P3  TWD 17  DBC      +1.49  TEH TEC    25    COLD  600UL 142  68    0.25  125  P2  TWD 11  10H      -0.24  TEH TEC    25    COLD  600UL 142  84    0.47  119 P3  TWD 17  DBC      +1.69  TEH TEC    27    COLD  600UL 142 86    0.20  116 P3  TWD 9  DBH      +1.90  TEH TEC    26    COLD  600UL 142  90    0.27    111 P3  TWD 11  DBH      +2.07  TEH TEC    27    COLD  600UL 142  98    0.29  15  P3  TWD 13  DBC      +1.44  TEH TEC    26    COLD  600UL 142  104  0.34  20  P3  TWD 13  DBH      +1.60  TEH TEC    29    COLD  60OUL 142  110  0.54  42  P3  TWD 19  DBH      +1.80  TEH TEC    29    COLD  600UL 143  83    0.49    38  P3  TWD 18  DBC      +1.57  TEH TEC    27    COLD  600UL 143  89    0.27    64  P3  TWD 11  DBH      -1.63  TEH TEC    26    COLD  600UL 143 109  0.23    126 P3  TWD 10  DBH      -1.57  TEH TEC    29    COLD  600UL 0.27    122 P2  TWD 13  VC2      +0.78  TEH TEC    29    COLD  600UL 0.46    73  2    SAT    03H      -0.85    03H 03H  152  HOT    580PP 144 76    0.19    48  P2  TWD 9  04H      -0.08  TEH TEC    26    COLD  600UL 0.38    130 P2  TWD 17  VC2      +0.92  TEN TEC    26    COLD  600UL 144 78    0.29    143 P2  TWD 13 VC2      +0.90    TEH TEC  26    COLD  600UL 0.43    122 P3  TWD 17 DBC      -1.53    TEH TEC  26    COLD  600UL 144  80  0.45    131  P3  TWD 18 DBH      +1.93    TEH TEC  26    COLD  600UL 144  86  0.31    139  P3  TWD 12 DBH      +1.97    TEH TEC  27    COLD  600UL 144 96    0.42    129 P3  TWD 17 DBH      +2.00    TEH TEC  26    COLD  60OUL 0.54    129 P3  TWD 20 DBC      +1.26    TEH TEC  26    COLD  600UL 145 79    0.59    100 P3  TWD 20 DBC        +1.69  TEH TEC  27    COLD  600UL 145 87    0.20    146 P3  TWD 8  DBC        -1.87  TEH TEC    26  COLD  600UL 0.19    34  P3  TWD 8  DBC        +1.81  TEH TEC    26  COLD  600UL 0.41    109 P2  TWD 18 VC1        +1.08  TEH TEC    26  COLD  60OUL 145 89    0.26    91  P3  TWD 10 DBH        -1.75  TEH TEC    27  COLD  600UL 0.34    48  P2  TWD 15 VC1        +0.85  TEh TEC    27  COLD  60OUL 146 82    0.32    151 P3  TWD 13 DBC        +1.69  TEH TEC    27    COLD  60OUL 0.20    56 P2    TWO 9  03H        -0.63  TEH TEC    27    COLD  600UL 146 86    0.17    95  P2  TWD 8  08C        +0.87  TEH TEC    27    COLD  60OUL 0.14  82  P3  TWD 6  DBH        +1.87  TEH TEC    27    COLD  60OUL 0.18  99  P3  TWD 7  DBC        +1.77  TEH TEC    27    COLD  600UL 146  94    0.23  78  P2  TWD 10 02H        +0.87  TEH TEC    27    COLD  600UL 0.58  61  P2  TWD 22 VHI        +1.22  TEH TEC    27    COLD  600UL
====


AREVA NP Inc                                            01/09/08 14:19:37 Customer Name:  San Onofre - Unit 2                    Component: S/G 88      Page 14 of 14 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,    0-100%,  PCS QUERY:  QueryM![11.qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION          EXT  EXT  CAL # LEG  PROBE 147  91  0.47    105 P2  TWD 19  VCl      -0.85  TEH  TEC  27    COLD 600UL Total Tubes    : 430 Total Records:  531
==


Inspection of Steam Generator Tubes                          Appendix 4 Special Report                                              Page 1 of 16 Appendix 4 Tube Inspection Summary Steam Generator E-089
====================


AREVA NP Inc                                              1/9/2008 2:18:16 PM Customer Name:  San Onofre - Unit 2                      Component: S/G 89          Page 2 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,      0-100%,  PCS QUERY:  QueryMl[2]
==  
ROW LINE VOLTS    DEG CHN IND %TW LOCATION            EXT EXT CAL # LEG      PROBE
=== ==== ======    === === === === ================        ==== === -------
                                                                      =      ------
2    122  0.30    95    2  SAI    01H      +0.74  01H 01H    170    HOT  58OPP 3    127  0.41    113 2    SAI    07C      +0.01  07C 07C    108    COLD  58OPP 5    119  0.53    89    2  SAI    07H      -0.50  07H 07H    169    HOT  580PP 0.33    86    2  SAI    07H      -0.30  07H 07H    169    HOT  580PP 0.33    85    2  SAI    07C      +0.61  07C 07C    108    COLD  580PP 6    58    0.33    16  P1  SCI    TSH      -6.31  TSH TSH    107    HOT  580PP 8    36    0.35    73    2  SAI    05H      -0.71  05H 05H    148    HOT  580PP 8    122  0.27    72  2  SAI    07H      -0.62  07H 07H    169    HOT  580PP 9    65    0.32    90  2  SAI    07H      +0.73  07H DBH    193    HOT  58OPP 9    117  0.26    93  2  SAI    05H      +0.91  05H 05H    170    HOT  580PP 10  44    0.31    75  2  SAI    05H      -0.83  05H 05H    145    HOT  58OPP 0.23    77  2  SAI    05H      +0.54  05H 05H    145    HOT  580PP 11  19    0.30    135 2    SAI    06H      +0.22  06H 06H    145    HOT  580PP 0.23    104 2    SAI    04H      -0.19  04H 04H    145    HOT  58OPP 11  55    0.37    101 2    SAI    05H      +0.94  05H 05H    157    HOT  580PP 11  65    0.30    67  2  SAI    01H      +0.54  01H 01H    203    HOT  58OPP 11  119  0.31    55  2  SAI    04H      -0.25  04H 04H    164    HOT  580PP 11  121  0.50    22  P1  SCI    TSH      -10.71  TSH TSH    82    HOT  580PP 11  131  0.72    14  P1  SCI    TSH      -13.59  TSH TSH    52    HOT  58OPP 12  114  0.40    130  2  SAI    06H      -0.16    06H 06H  215    HOT  520ET 12  128  0.22    121  2  SAI    01H      +0.58    01H 01H  168    HOT  58OPP 0.34    114  2  SAI    04H      +0.50    04H 04H  168    HOT  58OPP 13  37    0.20    33  P3  TWD 16  DBC      -0.09  TEC TEH    27    HOT  600UL 13  123  0.58    103  P2  TWD 22  07H      +0.62  TEH TEC    31    COLD  600UL 14  18    0.17    83  2  SAI    05H      +0.88    05H 05H  148    HOT    580PP 14  58    0.41    125 2    SAI    04H      +1.07    04H 04H  157    HOT    58OPP 15  131  0.43    19  P1  SCI    TSH      -0.10    TSH TSH  52    HOT    58OPP 15  141  0.54    21  P1  SCI    TSH      -0.08    TSH TSH    99    HOT    580PP 16  52    0.18    100 P3  TWD 11  DBH      -2.12    TEH TEC    34    COLD  600UL 16  56  0.12    96  2  SAI      06H      -1.39    06H 06H    157  HOT    58OPP 16  60  0.39    19  P1  SCI    TSH      -0.09    TSH TSH    66    HOT    58OPP 17  27    0.13    27    P3 TWD  11  DBC      +1.54    TEC TEH    19    HOT    600UL 17  43  0.13    20    P3 TWD 11  DBH      -1.90  TEC TEH    27    HOT    600UL 17  49  0.13    110 P1  SCI      TSH      +0.08  TSH TSH    71    HOT    58OPP 18  26  0.20    98    2  SAI      06H      -0.15  06H 06H    148    HOT  580PP 18  34  0.29    13    2  SAI      TSH      -5.71  TSH TSH    85    HOT  580PP 0.48    16    2  SAI      TSH      -5.26  TSH TSH    85    HOT  580PP 18  44  0.13    147  P3 TWD 11  DBH      -1.81  TEC TEH    27    HOT  600UL 18  122  0.36      110 P3  TWD 15  DBE      -1.89  TEH TEC    29    COLD  600UL 18  144  0.44      11  P3 TWD 19  DBh      +1.15  TEC TEN    14    HOT  600UL 19  109  0.23      124 P3  TWD 10  DBC      +1.33  TEH TEC    29    COLD  600UL 19  173  0.21      157 P2  TWD 12  VSM      +0.81  TEC TEH    22    HOT  60OUL 20  18  0.71      125 P2  TWD 26  VSm      -0.16  TEC TEH    16    HOT  600UL


AREVA NP Inc                                                      1/9/2008 2:18:16 PM Customer Name:  San Onofre - Unit 2                                Component: S/G 89            Page 3 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,      0-100%,  PCS QUERY:  QueryMi[2].qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION                    EXT EXT    CAL # LEG    PROBE
==  
=== ===-----------------------=---------------=====---==-------=-=-=-===-======-=------==-=----
= = =
20  108  0.17  122  P3 TWD 10  DBC       +1.77            TEH TEC    30    COLD  600UL 20  120  0.49  120 2   SAI    04H        +0.69            04H 04H    215  HOT   520ET 0.42  132 2    SAI    04H        -0.26            04H 04H    215  HOT    520ET 21  67   0.49  98  P2  TWD 22  VSM        +0.78            TEH TEC   36    COLD   600UL 22  2    0.33  129 P2   TWD 23  VSM       -0.91            TEC TEH    11    HOT    60OUL 22   50   5.84  186 4    PCS    SBH        +3.47  TO+10.13 STH SBH    128  HOT   500SP 22  118  0.43  126 P2  TWD 21  07H        +1.07            TEH TEC   30    COLD   600UL 23  23    0.27  50  P2  TWD 13  07H        +0.60            TEC TEH   20    HOT   60OUL 23  115  0.38  137 P2  TWD 16  VSM        +0.75            TEH TEC   29    COLD   600UL 23  137  0.32  22  P1  SCI    TSH        -0.14            TSH TSH    42    HOT    580PP 24  18    0.27  109 P2  TWD 12  VSM        -0.92            TEC TEH    16    HOT    600UL 24  50    0.23   103 P1  SCI    TSH        +0.12            TSH TSH    72    HOT    58OPP 24  130  0.19  120 P1  SCI    TSH        +0.08            TSH TSH    50    HOT    58OPP 24  154  0.18  49  P2  TWD 11  VSM        +0.25            TEC TEH    17    HOT    60OUL 25  49    0.16  95  P1  SCI    TSH        +0.09            TSH TSH    71    HOT    580PP 25   51    0.32  100 2    SAI    07C        -0.60            07C 07C    109  COLD   58OPP 25  149  0.26  73  2  SAI    06H        -0.38            06H 06H    169  HOT    580PP 28  54    0.37  111 2    SAI    TSH        +0.35            TSH TSH    71    HOT    58OPP 28  122  0.19  107 P1   MCI    TSH       +0.12            TSH TSH   81    HOT   58OPP 29  47    0.30  102 2    SAI    07H        +0.61            07H 07H    161  HOT    580PP 29  59    0.32  17   2  SAI    TSH        -3.59            TSH TSH    65    HOT   580PP 29  113  0.20  53   P3 TWD 12  DBH        -1.77            TEH TEC   30    COLD   600UL 30  70    0.35  136 P3   TWD 17  DBC       -1.46            TEH TEC   36    COLD   600UL 30  106  0.17  149  P3 TWD 10 DBC        -1.90            TEH TEC   30    COLD   600UL 30  134  0.47  20  P1  SCI    TSH        -6.96            TSH TSH    50    HOT    58OPP 31  45    0.36  51  P3 TWD 14  DBH       +1.64            TEC TEH    31    HOT    600UL 31  71    0.60  79  P3 TWD 27  DBH       -2.04            TEH TEC   36    COLD   600UL 0.26  129  P3 TWD 13  DBC       +1.79            TEH TEC   36    COLD   600UL 0.25  142  P3  TWD 12  DBC        -1.83            TEH TEC   36    COLD  600UL 32  48    0.45  23  P1 SCI     TSH       -0.09            TSH TSH   72   HOT   58OPP 33  67    0.26  83  2   SAI     04H        +0.50            04H 04H  205  HOT   58OPP 0.17    114 2  SAI    TSH       +0.47            TSH TSH   64    HOT   58OPP 0.21    100 2   SAI    TSH        +0.62           TSH TSH    64    HOT    580PP 34  112  0.28   83  2  SAT    04H        -0.34            04H 04H  159  HOT     58OPP 35  49  0.14    116 2  SAI    TSH        +0.27            TSH TSH  72    HOT    580PP 35  111  0.72    16  2  SAI    TSH        -0.98            TSH TSH    83    HOT    580PP 0.21   46  2    SAI    04H        -0.29            04H 04H    159  HOT     580PP 36  104  0.19    31  P3 TWD 11  DBC      -2.10            TEH TEC    30  COLD    600UL 36  114  0.35    112 P2 TWD 15  02H        +0.90            TEH TEC  29    COLD    60OUL 36  128  0.34    104 P1  MCI     TSH       +0.05            TSH TSH   75    HOT     58OPP 37  101  0.30    103 P3 TWD 17   DBC       +1.75            TEH TEC   24  COLD   600UL 0.26    136 P3 TWD 15  DBH      +1.75            TEH TEC   24    COLD   60OUL 37  103  0.52    78  P3 TWD  19  DBH      -1.87            TEH TEC  29    COLD    600UL 0.45    39  P3 TWD 17  DBC      +1.74            TEH TEC   29  COLD   600UL
50 74 0.23 16 P3 TWD 9 DBC  
+2.10 TEC TEH 45 HOT 600UL 0.21 75 P3 TWD 9 DBC
-2.00 TEC TEH 45 HOT 600UL 50 76 0.65 134 P3 TWD 23 DBC
-1.67 TEH TEC 23 COLD 600UL 50 100 0.38 121 P2 TWD 19 VSM  
+0.12 TEH TEC 22 COLD 600UL 50 106 0.27 105 P1 SCI TSH
+0.15 TSH TSH 87 HOT 580PP 51 77 0.27 149 ?3 TWD 15 DBC
+1.93 TEH TEC 24 COLD 60OUL 51 153 0.40 68 P3 TWD 19 DBC
+0.62 TEC TEH 18 HOT 600UL 52 76 0.47 121 P3 TWD 23 DBC
-1.85 TEH TEC 24 COLD 60OUL 52 78 0.27 157 P3 TWD 11 DBC
-1.86 TEH TEC 23 COLD 600UL 52 80 0.80 92 P3 TWD 26 DBC
-1.86 TEH TEC 23 COLD 600UL 52 84 0.39 150 P3 TWD 15 DBC
-2.06 TEH TEC 23 COLD 600UL 0.64 126 P3 TWD 22 DBH
-1.45 TEH TEC 23 COLD 600UL 0.87 90 P3 TWD 27 DBH
+1.88 TEH TEC 23 COLD 60OUL 0.39 158 P3 TWD 15 DBC
+1.88 TEH TEC 23 COLD 600UL 52 96 0.25 164 P3 TWD 16 DBH
-1.69 TEH TEC 22 COLD 60OUL 52 120 0.62 24 P1 SCI TSH  
-0.13 TSH TSH 82 HOT 580PP 52 158 0.50 91 P2 TWD 24 VH3
-0.96 TEC TEH 17 HOT 600UL 53 77 0.53 83 P3 TWD 19 DBC
-1.88 TEH TEC 23 COLD 60OUL 53 81 0.37 128 P3 TWD 15 DBC  
-1.62 TEH TEC 23 COLD 60OUL 0.26 36 P3 TWD 10 DBH
-1.95 TEH TEC 23 COLD 600UL 53 91 0.38 90 P3 TWD 20 DBH  
+1.79 TEH TEC 24 COLD 600UL 53 95 0.29 49 P3 TWD 17 DBH  
+1.84 TEH TEC 22 COLD 60OUL 0.41 63 P3 TWD 22 DBC  
+1.71 TEH TEC 22 COLD 600UL 53 155 0.34 46 P2 TWD 19 VH3
+0.47 TEC TEH 17 HOT 600UL 54 8
0.17 50 P2 TWD 14 01C
+0.10 TEC TEH 11 HOT 600UL 54 52 0.44 17 P1 SCI TSH  
-5.76 TSH TSH 72 HOT 58OPP 54 102 0.27 90 2
SAI 01H
+13.43 01H 02H 215 HOT 520ET 54 148 0.41 93 P2 TWD 21 VH3
-0.82 TEC TEH 13 HOT 600UL 55 45 0.36 25 P1 SCI TSH  
-0.16 TSH TSH 79 HOT 58OPP 55 79 0.37 29 P3 TWD 20 DEC
-2.00 TEH TEC 24 COLD 600UL 55 85 0.62 137 P3 TWD 22 DBH
+1.96 TEH TEC 23 COLD 60OUL 55 91 0.58 96 P3 TWD 21 DBC
+1.80 TEH TEC 23 COLD 60OUL 56 28 0.64 107 P2 TWD 24 VH3
-0.92 TEC TEH 24 HOT 600UL 56 92 0.37 122 P3 TWD 21 DBC
+1.92 TEH TEC 22 COLD 600UL 0.14 79 P3 TWD 10 DBC
-1.90 TEH TIC 22 COLD 600UL 56 150 0.41 105 P2 TWD 21 VH3
-0.91 TEC TEH 13 HOT 600UL 56 152 0.29
!!9 P3 TWD 18 DBH
+0.95 TEC TEH 13 HOT 600UL 56 158 0.48 90 P2 TWD 24 VH3
-0.76 TEC TEH 17 HOT 60OUL 57 77 0.25 92 Pl MCI TSH  
+0.07 TSH TSH 53 HOT 580PP 57 79 0.46 29 P3 TWD 17 DBC  
+1.80 TEH TEC 23 COLD 600UL 0.70 92 P3 TWD 24 DBC
-1.60 TEH TEC 23 COLD 600UL 57 97 0.50 15 2
SAI TSH
-4.39 TSH TSH 58 HOT 580PP 58 54 0.34 17 2
SAI TSH
-6.25 TSh TSH 71 HOT 58OPP 58 82 0.61 99 P3 TWD 22 DBH
+1.80 TEH TEC 23 COLD 600UL


AREVA NP Inc                                                   1/9/2008 2:18:16 PM Customer Name:    San Onofre - Unit 2                          Component: S/G 89                 Page 4 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,       0-100%,   PCS QUERY:   QueryMl[21.qry ROW LINE VOLTS     DEG CHN IND %TW LOCATION               EXT EXT   CAL # LEG   PROBE
AREVA NP Inc Customer Name:
--------------=-------------------=-====--------------==--===-------------==-==---------------=
San Onofre -
38  4      0.20  45  P2  TWD 16  01C        +0.06      TEC TEN   11    HOT   60OUL 0.23  36  P2  TWD 18  02C        -0.92      TEC TEN    11    HOT    600UL 38  8      0.23  93  2  SAI    06H        +0.70      06H 06H    148  HOT    58OPP 38  20    0.19  130  P3  TWD 14  DBH        +0.56      TEC TEN    19    HOT    600UL 38  104    0.25  68  P3  TWD 11  DBC        -1.76      TEH TEC   29    COLD   60OUL 39  45    0.18  107 P1  MCI    TSH        +0.04      TSH TSH    80    HOT    580PP 39  101    0.28  106 P3  TWO 11  DBC        -2.00      TEN TEC    23    COLD   60OUL 0.24  55 P3   TWD 10  DBC        +1.94      TEN TEC   23    COLD   60OUL 39  115    0.27  14  P3 TWD 15  DEN        +1.94      TEN TEC   30    COLD   60OUL 39  131    0.60   15  2  SAI    TSH        -7.50      TSH TSH    52    HOT    58OPP 0.47  14   2  SAI    TSH        -8.54      TSH TSH    52    HOT   580PP 39  133    0.24  86  P1  SCI    TSH        +0.03      TSH TSH    52    HOT    58OPP 0.73  21  2  SAI    TSH        -7.28      TSH TSH    52    HOT    58OPP 40  46    0.25  101 P1  SCI    TSH        +0.05      TSH TSH    80    HOT   580PP 40  60     0.33   110 2    SAI    TSH        +0.31      TSH TSH    65    HOT   58OPP 40  74    0.43  123  P3  TWD 20  DBC        -1.64      STH TEC   38    COLD  600UL 40  136    0.51  25  P1  SCI    TSH        -8.81      TSH TSH    99    HOT    58OPP 41  57    0.34  27  P3 TWD 13  DBH       +1.84      TEN TEC   33    COLD   600UL 41  63    0.48  58  P2  TWD 20  02H        +0.93      TEN TEC   35    COLD   60OUL 41  73    0.27  49  P3 TWD 14  DBC       -1.29      TEN TEC   36    COLD   60OUL 41  75    0.67  106 P3  TWD 22 DBC        +1.83      TEN TEC    35    COLD  60OUL 0.13  113 P3  TWD 6  DBC        -1.71      TEN TEC    35    COLD  60OUL 41  101  0.77  110 P3   TWD 25  DBC       +2.10      TEN TEC   23    COLD   600UL 41  113  0.24  25  P3 TWD 14  DBH       -1.86      TEN TEC   30    COLD   60OUL 41  119  0.42  71  P3 TWD 22  DBH       +1.88      TEN TEC   30    COLD   60OUL 41  131  0.57  18  P1 SCI     TSH       -0.16      TSH TSH   50    HOT   58OPP 41  143  0.24   50  P2  TWD 14  VSM        +0.78       TEC TEH    13    HOT    60OUL 42  38    0.91  27  P1  SCI    TSH        -0.12      TSH TSH    80    HOT  58OPP 42  168  0.54  156 P2   TWD 23  VSM        +0.90      TEC TEN   21    HOT   600UL 42  170  0.67    117 P2 TWD 27  VSM        -0.35        TEC TEN   22    HOT   60OUL 44  18    0.16    50  P2  TWD 7  VSM        +0.55        TEC TEN   16    HOT   600UL 0.32    128 P2 TWD 14  VSM        -0.92        TEC TEN   16    HOT   60OUL 44  74    0.67    59  P3 TWD 23  DBC      -2.14        TEN TEC    35    COLD  60OUL 0.23    67  P3 TWD 10  DBC       +2.00        TEN TEC   35    COLD   600UL 44  104  0.23    136  P3 TWD 13  DBH       +2.02        TEN TEC   30    COLD   60OUL 0.57    80  P2  TWD 25 VSM        +0.74        TEN  TEC   30    COLD   600UL 0.13    12  P2  TWD 7  VSN        -1.04      TEN  TEC   30    COLD   600UL 0.21    74  P3 TWD 13  DBE        -1.67      TEN  TEC   30    COLD   600UL 44  112  0.53    142  P2  TWD 20 VSM        -0.80      TEN TEC   29    COLD   60OUL 45  63    0.26    78  2  SAI    TSH      +0.19       TSH TSH    63    HOT    580PP 0.76    20  2  SAT    TSH        -3.16      TSH TSH    63    HOT   580PP 0.53    21   2   SAI     TSH        -2.39      TSH TSH    63    HOT    580PP 45  103  0.90    130 P2  TWD 29  VSE        +0.86      TEH TEC    29   COLD  600UL 0.39    131 P2  TWD 16 VSM        -0.80       TEN TEC    29    COLD  60OUL 0.26    144 P2  TWD 12  VSM        +0.00      TEN TEC   29    COLD   600UL 45  145  0.25    76  P2  TWD 15  VSM        -0.88      TEC TEN    13    HOT    600UL 46  48    0.13  103  P!  SCI    TSH        +0.14      TSH TSH    71    HOT    580PP
Unit 2 1/9/2608 2:18:16 PM Component:
S/G 89 Page 7 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2].qry ROW 58 LINE VOLTS 92 0.30 DEG CHN IND %TW LOCATION 17 P3 TWD 12 DBH EXT EXT CAL # LEG
+2.04 TEN TEC 21 COLD PROBE 600UL 58 94 0.41 78 P3 TWD 22 DBC 58 96 0.25 28 P3 TWD 10 DBH 0.30 94 P3 TWD 12 DEC 59 25 0.51 79 P2 TWD 21 VH3 59 53 0.25 24 P1 SCI TSH
-1.96
-1.68
-1.68
-1.00
-0.17 TEN TEC 22 COLD 600UL TEN TEC 21 COLD E0OUL TEN TEC 21 COLD 600UL TEC TEN 20 HOT 60OUL TSH TSH 71 HOT 58OPP 59 89 0.86 100 P3 TWD 32 DBH
-1.56 STN TEC 40 COLD 600UL 0.35 133 P2 TWD 18 VH3
+0.00 STH TEC 40 COLD 600UL 0.21 140 P2 TWD 12 VH3
-0.71 STH TEC 40 COLD 600UL 0.30 93 2
SAI 06C
-0.69 06C 06C 108 COLD 580PP 0.31 110 2 SAT VN3
+0.08 DBH VH3 120 COLD 560P2 59 95 0.46 118 P3 TWD 17 DBH
-1.56 TEN TEC 21 COLD 600UL 0.24 122 P3 TWD 9 DBC
+0.74 TEN TEC 21 COLD 600UL 59 147 0.60 106 P2 TWD 25 VH3
+0.93 TEC TEN 14 HOT 600UL 0.38 149 P2 TWD 18 VH3
-0.93 TEC TEN 14 HOT 600UL 60 28 0.33 126 P2 TWD 15 VH3
-0.98 TEC TEN 24 HOT 600UL 60 30 0.36 81 P2 TWD 16 VH3
-1.04 TEC TEN 24 HOT 600UL 60 88 0.77 139 P3 TWD 25 DBH  
+1.74 TEN TEC 23 COLD 600UL 60 94 0.46 103 P3 TWD 17 DBH
+1.68 TEN TEC 21 COLD 60OUL 0.60 138 P3 TWD 21 DBC  
-1.72 TEN TEC 21 COLD 60OUL 60 146 0.43 111 P2 TWD 22 VH3
-1.05 TEC TEN 13 HOT 600UL 60 158 0.35 122 P2 TWD 19 VH3
-0.99 TEC TEN 17 HOT 600UL 61 89 0.41 95 P3 TWD 21 DBC  
-2.08 TEN TEC 24 COLD 600UL 0.29 115 P3 TWD 17 DBH  
-1.85 TEN TEC 24 COLD 60OUL 61 91 0.60 14 P3 TWD 21 DBH  
+1.97 TEN TEC 23 COLD 600UL 62 74 0.22 95 2
SAI TSH
+1.36 TSH TSH 62 HOT 58OPP 62 92 0.20 96 P1 SCI TSH  
+0.13 TSH TSH 53 HOT 58OPP 63 87 0.55 110 P3 TWD 24 DBH
-1.49 STH TEC 40 COLD 600UL 0.18 149 P3 TWD 10 DBC
-1.78 STH TEC 40 COLD 600UL 63 99 0.23 55 P3 TWD 10 DBC
-1.33 TEN TEC 21 COLD 600UL 63 145 0.33 116 P2 TWD 18 VH3
+0.84 TEC TEN 13 HOT 600UL 64 10 0.36 109 P2 TWD 23 03C
-0.94 TEC TEN 15 HOT 600UL 0.07 45 P3 TWD 6 DBH
+1.67 TEC TEN 15 HOT 600UL 64 12 0.42 101 P2 TWD 25 VH3 64 76 0.28 111 2 SAI 05H
+0.66
+0.67 TEC TEN 15 HOT 600UL 05H 05H 146 HOT 580PP 64 80 0.35 15 2
SAI TSH
-2.87 TSH TSH 54 HOT 580PP 64 82 0.56 113 P3 TWD 26 DBC  
+2.01 TEN TEC 24 COLD 600UL 64 84 0.19 86 P1 SCI TSH
+0.09 TSH TSH 54 HOT 580PP 0.36 65 P3 TWD 19 DBH  
+1.75 TEN TEC 24 COLD 600UL 64 86 0.30 66 P3 TWD 16 DBH
-1.70 STH TEC 40 COLD 600UL 64 92 0.19 136 P3 TWD 11 DBH
-1.72 STH TEC 40 COLD 600UL 0.15 68 P3 TWD 9 DBC
-1.79 STH TEC 40 COLD 600UL 64 94 0.34 85 P3 TWD 19 DBC
-1.88 TEN TEC 22 COLD 600UL 64 150 0.34 147 P2 TWD 19 VH3
-0.93 TEC TEN 13 HOT 60OUL 65 37 0.21 89 2
SAI VSM
-0.93 66 78 0.29 87 P3 TWD 16 DBH
+1.91 66 80 0.44 116 P3 TWD 17 DEC
+1.89 VSM VSM 189 HOT 560P2 TEN TEC 24 COLD 600UL TEH TEC 23 COLD 600UL


AREVA N? Inc                                               1/9/2008 2:18i16 PM Customer Name:    San Onofre - Unit 2                      Component: S/G 89         Page 5 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,       0-100%,   PCS QUERY:     QueryMl[2).qry ROW LTNE VOLTS       DEG CHN IND %TW LOCATION           EXT EXT   CAL # LEG   PROBE
AREVA NP Inc Customer Name: San Onofre -
    ====== ======    === = = = = = = - - - - -
Unit 2 1/9/2008 2:18:17 PM Component:
TEN TEC   33    COLD   600UL 46    52    0.36  134  P2  TWD 15  VSM      -0.88  TEH TEC   33    COLD   600UL 0.28  163  P2  TWD 12  VSM      +0.80 TEH TEC   29    COLD   600UL 46    104    0.91  114  P2  TWD 29  VSM      -0.78  TEN TEC   29    COLD   600UL 0.54  139  P2 TWD 21  VSM      +0.78  TEH TEC    29    COLD  600UL 0.75  134  P2  TWD 26 VSM      +0.00 03H 03K    215    NOT  520ET 46    126    0.41  98  2  SAI    03H      -0.29 TEH TEC   31    COLD   600UL 46    128    0.41  136  P2 TWD 17  VSM       -0.89 46    134    0.47  91  2  SAI    06H      +0.16  06H 06H    169  HOT    58OPP 46    156    0.66  115 P2   TWD 28  VSM      -0.87   TEC TEH   18    HOT   60OUL 0.13  152 P2  TWD 8  VSM      +0.77  TEC TEH    18    HOT    600UL 46    162    0.27  63  P2 TWD 15 VSM      +0.89   TEC TEH    22    HOT    60OUL 46    170    0.22  37  P3 TWD 13  DBC      +1.52  TEC TEH    22    HOT    600UL 47    29    0.32  16   P3 TWD 22  DBH      -1.78  TEC TEH   23   HOT   600UL 47    33    0.36  48  P3 TWD 23  DBH      +1.82  TEC TEH   23    HOT   600UL 47    53    0.23  93  P2  TWD 13  VSM      +0.83  STH TEC    38    COLD  600UL 47    117    0.30  51  P3 TWD 17  DBH       +1.93  TEH TEC   30    COLD   60OUL 47    121    0.21  159 P2  TWD 12  VSM      -0.86  TEH TEC   30    COLD   600UL 48    6      0.39   78  P2 TWD 25  08C      -1.72  TEC TEH   11    HOT   600UL 48    8      0.25  115  P2 TWD 12  02C      +0.89   TEC TEH   12    HOT   600UL 48    12    0.35  86  2  SAI    04H      +0.61  04H 04H    148  HOT   580PP 48    34    0.20  27  P2 TWD 9  VSM      -0.60  TEC TEH   24    HOT   600UL 48    52    0.15  131  P1  SCI    TSH      +0.12  TSH TSH    71   HOT    580PP 48    64    0.43  14  2   SAI     TSH      -2.18  TSH TSH    63    HOT   58OPP 0.37  13  2  SAI    TSH       -1.43  TSH TSH   63    HOT   580PP 48    66    1.50  154  P2  TWD 38  VSM      -0.88  TEH TEC   35    COLD   600UL 48    100  0.63  24  P3 TWD 22  DBC      +1.90  TEH TEC   21    COLD   60OUL 48    118  0.47  40  P2  TWD 19  04H      -1.10  TEH TEC   29    COLD   600UL 48    130  0.36    18  P1  SCI    TSH      -0.13  TSH TSH    50    HOT    580PP 48    158  0.55    167 P2 TWD 26  VSM      -0'.74  TEC TEH   17    HOT   600UL 0.09    160 P2 TWD 6  VSM      +0.97  TEC TEH   17    HOT     600UL 49    39    0.22    135 P2 TWD 10  VSM       -0.80  TEC TEH   28    HOT   600UL 49    51    0.15    66  P1  MCI    TSH      +0.07  TSH TSH    71     HOT    58OPP 49    53    0.61    129 P2 TWD 23  08C      -1.51  TEH TEC    33    COLD  600UL 0.17    136 Pl  SCI    TSH      +0.09  TSH TSH    71    HOT   580PP 49    57    0.31    102 2    SAI    08H      +1.54    08H 08H  205    HOT    58OPP 49    65    0.31    135  P2 TWD 14 VSM        -0.71  TEH TEC    35    COLD  600UL 49    75    0.36    134  P3  TWD 14  DBC      -1.85  TEH TEC    35    COLD  600UL 49    103  0.41    153 P2  TWD 17 VSM        -0.80  TEH TEC    29    COLD  60OUL 49    145  0.54    102  P2  TWD 26  08H      -1.60  TEC TEH   13    HOT   600UL 18    NOT    600UL 49    159  0.58    133  P2  TWD 26 VSM        +0.76  TEC TEH   18    HOT   600UL 0.27   40  P2 TWD 15 VSM        +0.19  TEC TEH    18    HOT    60OUL 0.12    92  P2 TWD 8  VSM      -1.05  TEC TEH 50    16    0.15    48. P2 TWD 7  08H      +1.23   TEC TEH    16    HOT    60OUL 50    44    0.20    114 P2   TWD 15  VSM      -0.82  TEC TEH    27    HOT    600UL
S/G 89 Page 8 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMil[2].qry ROW LINE VOLTS DEG CNN IND %TW LOCATION EXT EXT CAL # LEG PROBE 66 84 0.24 21 P3 TWD 10 DBH
-1.80 TEH TEC 23 COLD 600UL 66 90 0.31 14 P3 TWD 17 DEC
-1.79 TEH TEC 24 COLD 60OUL 66 94 0.58 58 P3 TWD 20 DEC
+1.74 TEH TEC 21 COLD 60OUL 0.36 127 P3 TWD 14 DEC
-1.70 TEH TEC 21 COLD 60OUL 66 138 0.32 90 P2 TWD 16 08C
-0.90 TEC TEH 10 HOT 60OUL 67 83 0.79 74 P3 TWD 26 DEC
-1.76 TEH TEC 23 COLD 600UL 0.38 57 P3 TWD 15 DBH
-1.66 TEH TEC 23 COLD 60OUL 67 87 0.29 107 P2 TWD 11 VSM  
+0.88 TEH TEC 23 COLD 600UL 0.30 161 P3 TWD 12 DBH
+1.53 TEH TEC 23 COLD 60OUL 68 40 0.22 151 P2 TWD 16 VC3
+0.87 TEC TEH 27 HOT 60OUL 68 90 0.66 121 P3 TWD 23 DEC
-2.00 0.39 41 P3 TWD 15 DBH
-1.92 0.36 16 P3 TWD 14 DEC
+2.25 69 91 0.32 97 P3 TWD 13 DEC
+2.17 69 163 0.28 148 P2 TWD 15 02C
+0.89 70 24 0.21 166 P3 TWD 8 DEC
+2.05 0.16 16 P3 TWD 6 DEC
-1.48 TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEC TEH 22 HOT 600UL TEC TEH 20 HOT 600UL TEC TEH 20 HOT 600UL 70 52 0.37 153 P3 TWD 22 DEC
+1.29 TEC TEH 40 HOT 600UL 70 68 0.24 79 P1 SCI TSH
+0.06 TSH TSH 63 HOT 58OPP 70 90 0.21 146 P3 TWD 13 DBH  
-1.88 TEH TEC 24 COLD 600UL 70 92 0.29 20 2
SAI TSH
-2.27 TSH TSH 54 HOT 58OPP 70 94 0.57 124 P3 TWD 20 DEC
-1.85 TEH TEC 21 COLD 600UL 70 144 0.39 119 P2 TWD 19 VC3
-0.86 TEC TEH 14 HOT 600UL 0.36 32 P2 TWD 17 VSM
-0.89 TEC TEH 14 HOT 60OUL 70 152 0.37 141 P2 TWD 18 VH3
-0.76 TEC TEH 14 HOT 600UL 70 156 0.46 135 P2 TWD 23 VH3
-1.01 TEC TEH 18 HOT 600UL 70 164 0.32 72 P2 TWD 16 02C
-0.94 TEC TEH 21 HOT 60OUL 71 57 0.15 78 2
SAI 08H
+0.52 08H 08H 156 HOT 580PP 71 67 0.46 109 P1 SCI TSH  
+0.14 TSH TSH 64 HOT 58OPP 71 79 0.44 114 P3 TWD 22 DEC
-2.20 TEH TEC 24 COLD 600UL 71 91 0.27 143 P3 TWD 16 DEC
-1.85 TEN TEC 24 COLD 600UL 71 93 0.21 129 P3 TWD 13 DEC
-2.18 TEH TEC 22 COLD 600UL 71 143 0.23 58 P2 TWD 12 04C
-0.14 TEC TEN 14 NOT 600UL 0.22 159 P2 TWD 12 VC3
-0.88 TEC TEH 14 HOT 600UL 0.38 143 P2 TWD 18 VN3
-0.88 TEC TEH 14 HOT 600UL 0.42 134 P2 TWD 19 VSM  
+0.70 TEC TEH 14 HOT 600UL 71 147 0.37 127 P2 TWD 18 VC3
-0.82 TEC TEH 14 HOT 60OUL 0.62 101 P2 TWD 25 VH3
-0.92 TEC TEH 14 HOT 600UL 72 26 0.46 101 P2 TWD 19 VC3
+0.80 TEC TEH 20 HOT 600UL 72 28 0.21 153 P3 TWD 10 DEC
+0.71 TEC TEH 24 HOT 600UL 72 36 0.18 9
P3 TWD 9 DEC
+1.46 TEC TEH 24 HOT 600UL 72 38 0.26 92 P3 TWD 19 DEC
+1.98 TEC TEH 27 HOT 600UL 72 78 0.27 77 P2 TWD 11 VC3
+0.88 TEH TEC 23 COLD 60OUL 0.33 134 P2 TWD 13 VH3
+0.80 TEH TEC 23 COLD 600UL 0.58 82 P2 TWD 20 VH3
-0.99 TEH TEC 23 COLD 60OUL 72 80 0.47 145 P2 TWD 17 VC3
+0.84 TEH TEC 23 COLD 600UL


AREVA NP inc                                                        1/9/2008 2:18:16 PM Customer Name:   San Onofre -   Unit 2                             Component: S/G 89                 Page 6 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,       0-100%,   PCS QUERY:   QueryMl[2].qry ROW LINE VOLTS     DEG CHN IND %TW LOCATION                     EXT EXT   CAL # LEG   PROBE
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -
      = = = = = -          === === = ----------      = === == === ==== ===== ======== ==  == = = =
Unit 2 Component:
50  74      0.23  16  P3 TWD 9    DBC      +2.10            TEC TEH    45    HOT    600UL 0.21  75  P3  TWD 9    DBC      -2.00            TEC TEH    45    HOT    600UL 50  76      0.65  134  P3 TWD 23  DBC      -1.67            TEH TEC   23   COLD   600UL 50  100    0.38  121 P2   TWD 19  VSM      +0.12            TEH TEC    22    COLD  600UL 50  106    0.27  105 P1  SCI      TSH      +0.15            TSH TSH    87    HOT   580PP 51  77    0.27  149 ?3  TWD 15  DBC      +1.93            TEH TEC    24    COLD  60OUL 51  153    0.40  68  P3  TWD 19  DBC      +0.62            TEC TEH   18    HOT   600UL 52  76    0.47  121  P3  TWD 23  DBC      -1.85            TEH TEC   24    COLD  60OUL 52  78    0.27  157  P3  TWD 11  DBC      -1.86            TEH TEC    23    COLD  600UL 52  80    0.80  92  P3  TWD 26  DBC      -1.86            TEH TEC    23    COLD  600UL 52  84    0.39  150 P3  TWD 15  DBC      -2.06            TEH TEC  23    COLD  600UL 0.64  126 P3   TWD 22  DBH       -1.45            TEH TEC  23    COLD  600UL 0.87  90  P3 TWD 27  DBH      +1.88            TEH TEC   23   COLD   60OUL 0.39  158 P3  TWD 15  DBC      +1.88            TEH TEC  23    COLD  600UL 52  96    0.25  164  P3 TWD 16  DBH      -1.69            TEH TEC    22    COLD  60OUL 52  120    0.62  24  P1  SCI      TSH      -0.13            TSH TSH    82    HOT   580PP 52  158    0.50  91  P2 TWD 24  VH3      -0.96            TEC TEH   17    HOT   600UL 53  77    0.53  83  P3  TWD 19  DBC      -1.88            TEH TEC    23    COLD  60OUL 53  81    0.37  128  P3 TWD 15  DBC      -1.62            TEH TEC   23    COLD  60OUL 0.26  36  P3 TWD 10  DBH       -1.95            TEH TEC    23    COLD  600UL 53  91    0.38  90  P3 TWD 20  DBH      +1.79            TEH TEC   24   COLD   600UL 53  95    0.29  49  P3 TWD 17  DBH       +1.84            TEH TEC   22   COLD   60OUL 0.41    63  P3 TWD 22  DBC      +1.71            TEH TEC    22    COLD  600UL 53  155    0.34  46  P2 TWD 19  VH3      +0.47            TEC TEH   17    HOT   600UL 54  8      0.17    50  P2 TWD 14  01C      +0.10            TEC TEH   11    HOT   600UL 54  52    0.44   17  P1  SCI    TSH      -5.76            TSH TSH    72    HOT   58OPP 54  102    0.27    90  2    SAI    01H      +13.43            01H 02H  215    HOT   520ET 54  148    0.41   93  P2 TWD 21   VH3       -0.82            TEC TEH   13    HOT   600UL 55  45    0.36    25  P1   SCI     TSH       -0.16            TSH TSH   79    HOT   58OPP 55  79    0.37    29  P3   TWD 20  DEC     -2.00            TEH TEC    24    COLD   600UL 55  85    0.62    137 P3   TWD 22  DBH      +1.96            TEH TEC   23     COLD   60OUL 55  91    0.58    96  P3 TWD 21  DBC      +1.80            TEH TEC   23     COLD   60OUL 56  28    0.64    107  P2 TWD 24  VH3      -0.92            TEC TEH  24    HOT    600UL 56  92    0.37    122  P3  TWD 21  DBC      +1.92            TEH TEC   22     COLD   600UL 0.14    79  P3  TWD 10  DBC      -1.90            TEH TIC  22    COLD  600UL 56  150  0.41    105  P2  TWD 21  VH3      -0.91            TEC TEH   13    HOT   600UL 56   152  0.29    !!9  P3 TWD 18  DBH     +0.95            TEC TEH   13    HOT   600UL 56  158  0.48    90  P2 TWD 24  VH3      -0.76            TEC TEH   17    HOT    60OUL 57  77    0.25    92  Pl  MCI    TSH      +0.07            TSH TSH    53    HOT    580PP 57  79    0.46    29  P3 TWD 17  DBC      +1.80            TEH TEC   23   COLD   600UL 0.70    92  P3 TWD 24  DBC      -1.60            TEH TEC   23   COLD   600UL 57  97    0.50    15  2   SAI      TSH      -4.39            TSH TSH    58    HOT    580PP 58  54    0.34    17  2  SAI      TSH      -6.25            TSh TSH    71    HOT   58OPP 58  82    0.61    99  P3 TWD 22  DBH      +1.80            TEH TEC    23    COLD  600UL
S/G 89 Page 9 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAT, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CNN TD %TW LOCATION EXT EXT CAL 4 LEG PROBE 72 84 0.39 130 P3 TWD 15 DEC
-1.78 TEH TEC 23 COLD 60OUL 0.37 130 P2 TWD 14 VH3
-0.84 TEH TEC 23 COLD 60OUL 72 90 0.39 94 P3 TWD 15 DEC
-2.22 TEN TEC 23 COLD 600UL 72 114 0.26 84 P2 TWD 14 VC3
+0.87 TEC TEH 32 HOT 60OUL 72 126 0.44 127 P2 TWD 22 VSM
-0.82 TEC TEH 33 HOT 600UL 0.42 104 P2 TWD 21 VH3
-0.12 TEC TEH 33 HOT 600UL 72 156 0.24 107 P2 TWD 14 VC3
-0.93 TEC TEH 17 HOT 600UL 73 13 0.25 85 P2 TWD 18 VH3
+0.80 TEC TEH 15 HOT 60OUL 73 51 0.30 142 P3 TWD 19 DBH  
-1.10 TEC TEH 40 HOT 600UL 73 91 0.47 21 P3 TWD 18 DEC
+2.21 TEH TEC 23 COLD 60OUL 73 157 0.31 131 P2 TWD 17 VH3
+1.09 TEC TEH 17 HOT 600UL 73 163 0.13 44 P3 TWD 6 DEC
+1.54 TEC TEH 21 HOT 60OUL 74 18 0.13 152 P3 TWD 11 DEC
+2.06 TEC TEH 15 HOT 600UL 74 44 0.16 71 P2 TWD 12 VSM
+0.76 TEC TEH 27 HOT 600UL 0.50 133 P2 TWD 27 VH3
-0.80 TEC TEH 27 HOT 60OUL 74 50 0.32 161 P3 TWD 20 DBH
+1.89 TEC TEN 40 HOT 60OUL 74 56 0.23 49 P3 TWD 9 DBH  
+0.97 TEC TEH 41 HOT 60OUL 74 90 0.41 123 P3 TWD 21 DEC
-1.75 TEH TEC 24 COLD 600UL 74 94 0.20 35 P3 TWD 12 DBH  
-1.63 TEH TEC 22 COLD 60OUL 74 124 0.20 96 P3 TWD 9 DEC
-1.77 TEC TEH 33 HOT 600UL 74 132 0.28 103 P2 TWD 15 VC3
-0.99 TEC TEH 10 HOT 600UL 74 148 0.31 126 P2 TWD 18 VSM
-0.95 TEC TEH 13 HOT 600UL 0.44 55 P2 TWD 22 VH3
-0.93 TEC TEH 13 HOT 600UL 74 156 0.59 46 P2 TWD 26 VC3
-0.76 TEC TEH 18 HOT 600UL 0.41 87 P2 TWD 21 VSM
-0.85 TEC TEH 18 HOT 60OUL 0.57 95 P2 TWD 26 VH3  
-0.87 TEC TEH 18 HOT 600UL 75 15 0.10 162 P3 TWD 8 DBH
+1.29 TEC TEH 11 HOT 600UL 75 23 0.14 46 P3 TWD 12 DEC
+1.69 TEC TEH 19 HOT 600UL 75 51 0.15 94 P3 TWD 6 DBH
-2.24 TEC TEH 41 HOT 60OUL 75 53 0.12 91 P1 SCI TSH  
-0.03 TSH TSH 71 HOT 58OPP 75 83 0.51 54 P3 TWO 19 DEC  
-2.01 TEN TIC 23 COLD 600UL 75 87 0.51 19 P3 TWD 19 DEC
+2.25 TEH TEC 23 COLD 600UL 0.70 119 P3 TWD 24 DEC
-2.23 TEH TEC 23 COLD 600UL 75 97 0.23 85 P2 TWD 13 VC3
-0.88 TEH TEC 22 COLD 600UL 0.34 105 P2 TWD 18 VC3
+0.90 TEH TEC 22 COLD 60OUL 75 103 0.19 139 P2 TWD 11 VC3
+0.91 TEC TEH 38 HOT 600UL 76 42 0.22 126 P3 TWD 16 DEC
-1.79 TEC TEH 27 HOT 600UL 76 56 0.32 21 P3 TWD 20 DBH  
+1.18 TEC TEH 40 HOT 600UL 76 78 0.27 143 P2 TWD 15 VC3
-0.86 TEH TEC 24 COLD 600UL 0.55 125 P2 TWD 25 VC3
+0.86 TEH TEC 24 COLD 600UL 0.26 117 P2 TWD 15 VH3
+0.84 TEH TEC 24 COLD 600UL 76 84 0.37 5
P3 TWD 15 DEC
+2.15 TEI TEC 23 COLD 60OUL 76 90 0.42 118 P3 TWD 16 DEC
-2.00 TEH TEC 23 COLD 600UL 0.30 33 P3 TWD 12 DBC
+2.15 TEH TEC 23 COLD 600UL 76 114 0.38 78 P2 TWD 19 VH3
-0.87 TEC TEH 32 HOT 600UL 76 138 0.14 14 P3 TWD 8 DEC
+1.93 TEC TEH 9
HOT 600UL


AREVA NP Inc                                               1/9/2608 2:18:16 PM Customer Name:    San Onofre - Unit 2                      Component: S/G   89       Page 7 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,     0-100%,   PCS QUERY:   QueryMl[2] .qry ROW LINE VOLTS     DEG CHN IND %TW LOCATION             EXT EXT   CAL # LEG     PROBE 58  92    0.30    17  P3  TWD 12  DBH      +2.04    TEN TEC   21    COLD    600UL 58  94    0.41    78  P3  TWD 22 DBC      -1.96    TEN TEC   22    COLD  600UL
AREVA NP Inc Customer Name: San Onofre -
                                              -1.68    TEN TEC    21    COLD  E0OUL 58  96    0.25    28  P3 TWD 10 DBH      -1.68    TEN TEC   21    COLD  600UL 0.30   94  P3  TWD 12  DEC 59  25    0.51    79  P2 TWD 21  VH3       -1.00    TEC TEN    20    HOT   60OUL 59  53    0.25    24  P1  SCI    TSH      -0.17    TSH TSH    71    HOT   58OPP 59  89    0.86    100  P3  TWD 32  DBH      -1.56    STN  TEC   40    COLD  600UL 0.35    133  P2 TWD 18  VH3      +0.00    STH  TEC   40    COLD  600UL 0.21    140  P2 TWD 12  VH3      -0.71    STH  TEC   40    COLD  600UL 0.30    93  2  SAI    06C      -0.69    06C  06C  108    COLD  580PP 0.31   110  2  SAT    VN3      +0.08    DBH  VH3   120    COLD  560P2 59  95    0.46    118  P3  TWD 17  DBH      -1.56    TEN TEC   21    COLD  600UL 0.24    122  P3  TWD 9  DBC      +0.74    TEN TEC   21    COLD  600UL 59  147  0.60    106 P2   TWD 25  VH3      +0.93    TEC TEN    14    HOT   600UL 0.38    149 P2  TWD 18  VH3      -0.93    TEC TEN    14    HOT   600UL 60  28    0.33   126 P2   TWD 15  VH3      -0.98    TEC TEN    24     HOT   600UL 60  30    0.36    81  P2 TWD 16  VH3      -1.04    TEC TEN    24    HOT   600UL 60  88    0.77    139 P3  TWD 25  DBH      +1.74    TEN TEC   23    COLD   600UL 60  94    0.46    103 P3  TWD 17  DBH      +1.68    TEN TEC   21    COLD    60OUL 0.60    138 P3   TWD 21  DBC       -1.72    TEN TEC   21    COLD  60OUL 60  146  0.43    111 P2  TWD 22  VH3      -1.05    TEC TEN   13    HOT     600UL 60  158  0.35    122 P2   TWD 19  VH3       -0.99    TEC TEN    17    HOT     600UL 61  89    0.41    95  P3  TWD 21 DBC      -2.08    TEN TEC    24    COLD    600UL 0.29    115 P3  TWD 17  DBH      -1.85    TEN TEC    24    COLD    60OUL 61  91    0.60    14  P3  TWD 21  DBH      +1.97    TEN TEC   23     COLD   600UL 62  74    0.22    95  2   SAI     TSH       +1.36    TSH TSH   62    HOT     58OPP 62  92    0.20    96  P1 SCI     TSH       +0.13    TSH TSH   53    HOT     58OPP 63  87    0.55    110 P3   TWD 24  DBH       -1.49    STH TEC   40    COLD    600UL 0.18    149 P3  TWD 10  DBC      -1.78    STH TEC   40    COLD    600UL 63  99    0.23    55  P3  TWD 10  DBC      -1.33    TEN TEC    21    COLD    600UL 63  145  0.33   116 P2   TWD 18 VH3      +0.84    TEC TEN    13    HOT    600UL 64  10  0.36    109  P2 TWD 23  03C      -0.94    TEC TEN    15    HOT    600UL 0.07    45    P3 TWD 6  DBH      +1.67    TEC TEN    15    HOT    600UL 4                                          +0.66 6    12   0.42    101 P2  TWD 25  VH3                TEC TEN    15    HOT    600UL
Unit 2 1/9/2008 2:18:17 PM Component:
                                              +0.67 64  76  0.28    111 2    SAI    05H                  05H 05H    146  HOT    580PP 64  80  0.35    15    2  SAI    TSH      -2.87    TSH TSH    54    HOT    580PP 64  82  0.56    113  P3  TWD 26 DBC      +2.01    TEN TEC    24    COLD    600UL 64  84  0.19    86    P1  SCI    TSH      +0.09    TSH TSH    54    HOT    580PP 0.36    65    P3 TWD 19 DBH       +1.75    TEN TEC     24    COLD   600UL 64  86  0.30    66    P3  TWD 16 DBH      -1.70      STH TEC    40    COLD    600UL 64  92  0.19    136  P3  TWD 11 DBH      -1.72      STH TEC    40    COLD    600UL 0.15    68    P3  TWD 9  DBC      -1.79      STH TEC    40    COLD    600UL 64  94    0.34    85  P3  TWD 19  DBC      -1.88      TEN TEC    22    COLD    600UL 64  150  0.34    147  P2 TWD 19 VH3       -0.93    TEC TEN    13    HOT    60OUL 65  37    0.21    89  2  SAI    VSM        -0.93    VSM VSM    189  HOT    560P2 66  78    0.29    87  P3  TWD 16 DBH      +1.91    TEN TEC    24    COLD    600UL 66  80    0.44    116  P3  TWD 17  DEC      +1.89    TEH TEC   23    COLD    600UL
S/G 89 Page 10 of 16 Post U2C1S Inspection Final Report MAT, MCI, MMI, MVI, SAT, SCI, SVI, 0-100%, PCS QUERY: QueryMi [2[.ary ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 76 142 0.21 91 P2 TWD 13 08C
-0.49 TEC TEH 13 HOT 600UL 76 160 0.43 74 P2 TWD 22 VH3
+0.84 TEC TEH 17 HOT 600UL 77 27 0.24 80 P3 TWD 10 DBC
-1.69 TEC TEH 20 HOT 600UL 77 43 0.30 124 22 TWD 13 VH3
+0.78 TEC TEH 28 HOT 60OUL 77 113 0.18 103 P2 TWD 11 VH3  
-1.04 TEC TEH 33 HOT 60OUL 77 137 0.64 98 P2 TWD 26 VSM
-0.90 TEC TEH 10 HOT 60OUL 77 139 0.60 132 P2 TWD 25 VC3
+0.77 TEC TEH 10 HOT 60OUL 0.25 99 P2 TWD 13 VC3
-0.90 TEC TEH 10 HOT 600UL 0.33 61 P2 TWD 17 VSM
-0.92 TEC TEH 10 HOT 600UL 0.31 105 P2 TWD 16 VH3  
-1.03 TEC TEH 10 HOT 600UL 77 157 0.38 75 P2 TWD 20 VH3
-0.95 TEC TEH 17 HOT 60OUL 78 26 0.24 130 P2 TWD 18 07C
-0.14 TEC TEH 19 HOT 600UL 78 28 0.07 138 P3 TWD 6 DBC
-1.65 TEC TEH 23 HOT 600UL 78 44 0.33 127 P2 TWD 21 VSM
-0.78 TEC TEH 27 HOT 600UL 78 58 0.24 173 P3 TWD 16 DBH
+1.61 TEC TEH 40 HOT 60OUL 78 130 0.31 132 P2 TWD 15 VSM
-1.02 TEC TEH 10 HOT 60OUL 78 136 0.26 144 P2 TWD 14 VC3
-0.89 STH TEC 38 COLD 600UL 78 150 0.57 64 P2 TWD 24 VH3
-0.74 TEC TEH 14 HOT 60OUL 78 160 0.30 124 P3 TWD 15 DBC  
-1.56 TEC TEH 18 HOT 60OUL 79 15 0.13 117 P3 TWD 10 DBH
+1.21 TEC TEN 11 HOT 600UL 79 43 0.23 45 P2 TWD 16 VH3  
-0.62 TEC TEH 27 HOT 600UL 79 53 0.57 21 P1 SCI TSH
-0.02 TSH TSH 71 HOT 580PP 79 79 0.41 143 P2 TWD 16 VH3
-0.92 TEH TEC 23 COLD 600UL 79 89 0.17 108 2 SAI TSH  
+1.00 TSH TSH 53 HOT 58OPP 79 99 0.33 125 P1 SCI TSH  
-0.00 TSH TSH 57 HOT 580PP 80 72 0.20 88 P3 TWD 15 DBH  
-2.24 TEC TEH 44 HOT 600UL 80 106 0.29 78 P2 TWD 16 VH3
+0.91 TEC TEH 32 HOT 600UL 80 152 0.59 108 P2 TWD 27 VC3
+0.86 0.67 105 P2 TWD 29 VC3
-0.80 0.33 123 P2 TWD 18 VSM
+0.86 0.52 137 P2 TWD 25 VSM
-0.82 80 160 0.63 117 P3 TWD 27 DBC
-1.59 81 21 0.15 87 P3 TWD 12 DBE
+0.78 81 25 0.13 158 P3 TWD 10 DBC
-1.38 81 75 0.34 125 22 TWD 17 VC3
+0.86 0.27 81 79 0.94 0.37 24 P3 TWD 13 100 P2 TWD 30 124 P2 TWD 15 DBH VH3 VC 3 TEC TEH 13 HOT 60OUL TEC TEH 13 HOT 600UL TEC TEH 13 HOT 600UL TEC TEH 13 HOT 600UL TEC TEH 17 HOT 600UL TEC TEN 11 NOT 600UL TEC TEH 11 HOT 600UL TEN TEC 17 COLD 600UL TEN TEC 17 COLD 600UL TEH TEC 13 COLD 60OUL TEH TEC 13 COLD 60OUL TEN TEC 9
COLD 6000L TEH TEC 9
COLD 600UL TEC TEN 5
NOT 600UL TEC TEN S
NOT D 60UL TEC TEH 9
HOT 60OUL TEC TEH 9
POT 600UL 81 105 0.55 148
?2 TWD 21 VH3
+0.99 0.29 114 P2 TWD 12 VSM
+0.87 81 135 0.41 123 P2 TWD 20 VH3
+0.92 0.24 157 P2 TWD 14 VH3
-0.73 81 159 0.33 72 P2 TWD 17 VH3  
-0.87 0.26 87 P2 TWD 14 02H
-0.36 82 28 0.20 92 P2 TWD 16 VH3
-0.19 0.23 99 22 TWD 18 VH3
-0.68 TEC TEH 11 HOT TEC TEH 11 HOT 600UL - -- --
600UL


AREVA NP   Inc                                             1/9/2008 2:18:17 PM Customer   Name: San Onofre   - Unit 2                   Component: S/G 89         Page 8 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,       0-100%,   PCS QUERY:   QueryMil[2].qry ROW LINE VOLTS     DEG CNN IND %TW LOCATION             EXT EXT   CAL # LEG   PROBE 66  84    0.24    21    P3  TWD 10  DBH      -1.80  TEH TEC   23    COLD  600UL 66  90    0.31    14    P3  TWD 17  DEC      -1.79  TEH TEC    24    COLD  60OUL 66  94    0.58  58    P3  TWD 20   DEC      +1.74  TEH TEC   21    COLD   60OUL 0.36  127   P3  TWD 14  DEC      -1.70  TEH TEC   21    COLD   60OUL 66  138    0.32  90    P2 TWD 16  08C      -0.90  TEC TEH   10    HOT   60OUL 67  83     0.79  74    P3  TWD 26  DEC      -1.76  TEH TEC    23    COLD  600UL 0.38  57    P3  TWD 15  DBH      -1.66  TEH TEC   23    COLD   60OUL 67  87    0.29  107  P2 TWD 11  VSM      +0.88  TEH TEC   23    COLD   600UL 0.30  161  P3 TWD 12  DBH      +1.53  TEH TEC   23    COLD   60OUL 68   40    0.22  151  P2 TWD 16  VC3      +0.87  TEC TEH    27    HOT    60OUL 68  90    0.66  121  P3  TWD 23  DEC      -2.00  TEH TEC   23    COLD  600UL 0.39  41    P3  TWD 15  DBH      -1.92  TEH TEC    23    COLD  600UL 0.36  16    P3  TWD 14  DEC      +2.25  TEH TEC    23    COLD  600UL 69  91    0.32  97    P3  TWD 13  DEC      +2.17  TEH TEC    23    COLD  600UL 69  163    0.28  148  P2 TWD 15  02C      +0.89  TEC TEH   22    HOT   600UL 70  24    0.21  166 P3    TWD 8    DEC      +2.05  TEC TEH    20    HOT    600UL 0.16  16    P3  TWD 6    DEC      -1.48  TEC TEH   20    HOT   600UL 70  52    0.37  153  P3 TWD 22  DEC      +1.29  TEC TEH   40    HOT   600UL 70  68    0.24  79    P1  SCI      TSH       +0.06  TSH TSH   63    HOT   58OPP 70  90     0.21  146 P3    TWD 13  DBH      -1.88  TEH TEC   24    COLD   600UL 70  92    0.29  20    2   SAI     TSH      -2.27  TSH TSH    54    HOT    58OPP 70  94    0.57    124 P3  TWD 20   DEC      -1.85  TEH TEC    21    COLD  600UL 70  144    0.39    119 P2  TWD 19  VC3      -0.86  TEC TEH    14    HOT   600UL 0.36  32    P2 TWD 17  VSM      -0.89  TEC TEH    14    HOT   60OUL 70  152    0.37    141 P2   TWD 18  VH3      -0.76  TEC TEH    14    HOT    600UL 70  156    0.46    135 P2   TWD 23  VH3       -1.01  TEC TEH    18    HOT   600UL 70  164    0.32    72  P2 TWD 16  02C      -0.94  TEC TEH   21    HOT   60OUL 71    57    0.15    78  2   SAI     08H      +0.52    08H 08H  156    HOT   580PP 71    67    0.46    109  P1  SCI      TSH      +0.14    TSH TSH  64    HOT   58OPP 71  79    0.44    114  P3  TWD 22  DEC      -2.20    TEH TEC  24    COLD  600UL 71    91    0.27    143  P3  TWD 16  DEC      -1.85    TEN TEC    24    COLD  600UL 71    93    0.21    129  P3 TWD 13  DEC      -2.18    TEH TEC   22    COLD  600UL 71  143  0.23    58  P2 TWD 12  04C      -0.14    TEC TEN    14    NOT    600UL 0.22    159  P2  TWD 12  VC3      -0.88    TEC TEH   14    HOT   600UL 0.38   143  P2 TWD 18  VN3      -0.88    TEC TEH    14    HOT    600UL 0.42    134 P2   TWD 19  VSM      +0.70    TEC TEH   14    HOT    600UL 71  147  0.37    127 P2   TWD 18  VC3      -0.82    TEC TEH    14    HOT    60OUL 0.62    101 P2   TWD 25  VH3       -0.92   TEC TEH   14    HOT   600UL 72  26    0.46    101 P2   TWD 19  VC3       +0.80   TEC TEH    20   HOT    600UL 72  28    0.21    153 P3   TWD 10  DEC      +0.71    TEC TEH    24    HOT    600UL 72  36    0.18    9    P3  TWD 9    DEC      +1.46    TEC TEH    24    HOT   600UL 72  38    0.26    92  P3  TWD 19    DEC      +1.98    TEC TEH    27    HOT    600UL 72  78    0.27    77  P2 TWD 11  VC3      +0.88    TEH TEC    23    COLD  60OUL 0.33    134 P2  TWD 13  VH3       +0.80   TEH TEC   23    COLD   600UL 0.58    82    P2 TWD 20  VH3      -0.99    TEH TEC    23    COLD  60OUL 72  80    0.47    145 P2  TWD 17  VC3      +0.84    TEH TEC   23    COLD  600UL
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -
Unit 2 Component:
S/G 89 Page 11 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 82 44 0.22 138 P2 TWD 13 VH3
+0.91 TEC TER 7
HOT 600UL 82 68 0.42 140 P2 TWD 20 VH3
+0.86 TEH TEC 17 COLD 600UL 0.89 127 P2 TWD 32 VH3
-0.86 TEM TEC 17 COLD 60OUL 82 148 0.61 125 P2 TWD 26 VH3
-0.89 TEC TEH 9
HOT 600UL 83 73 0.29 111 2 SAI 03H
-0.11 03H 03H 171 HOT 580PP 84 40 0.38 64 P2 TWD 22 VH2
-1.14 TEC TEH 8
HOT 600UL 84 100 0.47 66 P2 TWD 22 09H
-1.59 TEH TEC 12 COLD 60OUL 84 108 0.40 127 P2 TWD 19 09H
+0.39 TEH TEC 10 COLD 600UL 85 81 0.31 102 P1 SCI TSH
+0.19 TSH TSH 107 HOT 580PP 85 91 0.25 93 P3 TWD 9 DBC
-1.85 TEN TEC 11 COLD 60OUL 86 68 0.37 42 P2 TWD 19 VH2
+0.82 TEN TEC 17 COLD 60OUL 86 130 0.37 114 P2 TWD 19 VH2
-0.77 TEC TEH 5
HOT 600UL 87 31 0.82 19 2
SAI 05H
+0.33 05H 05H 143 HOT 580PP 87 47 0.18 105 2 SAT 03H
-0.21 03H 03H 165 HOT 58OPP 87 131 0.35 122 P2 TWD 18 VH2
+0.66 TEC TEH 5
HOT 600UL 88 40 0.23 76 P2 TWD 14 VSM
-0.93 TEC TEH 8
HOT 60OUL 89 25 0.14 36 P3 TWD 11 DBH
+0.04 TEC TEH 11 HOT 600UL 89 93 0.48 17 2
SAI TSH  
-13.00 TSH TSH 113 HOT 580PP 90 122 0.38 140 P2 TWD 19 VH2
-0.78 TEN TEC 8
COLD 60OUL 91 85 0.33 104 2
SAI 03H
+0.20 03H 03H 176 HOT 580PP 93 113 0.35 67 2
SAT 02H
+0.84 02H 02H 174 HOT 580PP 94 22 0.23 93 P2 TWD 11 02C
+0.93 TEC TEN 12 HOT 60OUL 94 50 0.33 133 P2 TWD 14 05C
-0.12 TEN TEC 21 COLD 60OUL 94 146 0.23 124 P2 TWD 14 VH3  
-0.96 TEC TER 5
HOT 600UL 97 37 0.50 115 P2 TWD 26 VC3
+0.95 TEC TEH 8
HOT 600UL 98 62 1.26 20 2
SAI TSH
-13.92 TSH TSH 101 HOT 580PP 98 82 0.31 100 2 SAI 01H
-0.44 01H 01H 176 HOT 58OPP 99 131 0.30 124 P2 TWD 16 VH2
+0.73 TEC TEH 5
HOT 600UL 101 25 0.33 118 P2 TWD 15 08H
+0.47 TEC TEN 12 HOT 600UL 101 33 0.20 20 P3 TWD 12 DBC
+2.00 TEC TEN 7
HOT 600UL 101 39 0.32 99 P2 TWD 19 VH2
+0.85 TEC TEH 8
HOT 600UL 101 143 0.24 121 P3 TWD 15 DBH
+1.84 TEC TEH 5
HOT 600UL 102 58 0.38 124 P2 TWD 16 VH3
+0.86 TEN TEC 19 COLD 600UL 0.25 109 P2 TWD 11 VC3
+0.86 TEN TEC 19 COLD 60OUL 0.21 150 P2 TWD 10 VC3
-0.82 TEH TEC 19 COLD 600UL 0.25 125 P2 TWD 11 VC2
-0.89 TEN TEC 19 COLD 60OUL 103 137 0.39 92 P2 TWD 20 VH3  
-0.92 TEC TEH 6
HOT 60OUL 105 61 0.20 141 P2 TWD 11 VC3  
-0.80 TEN TEC 20 COLD 600UL 105 141 0.19 148 P3 TWD 12 DBH
+1.78 TEC TEN 5
HOT 600UL 106 84 0.34 120 P2 TWD 15 VH3  
+0.80 TEH TEC 13 COLD 600UL 106 126 0.44 94 2
MAI 02H
+0.24 02H 02H 174 HOT 580P?
107 33 0.21 38 P3 TWD 16 DBC
+1.65 TEC TER 7
HOT 60OUL


AREVA NP Inc                                             1/9/2008 2:18:17 PM Customer Name: San Onofre - Unit 2                       Component: S/G 89           Page 9 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAT, SCI, SVI,   0-100%,   PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CNN TD %TW LOCATION             EXT EXT     CAL 4 LEG   PROBE 72  84  0.39  130  P3 TWD 15  DEC        -1.78  TEH TEC     23    COLD   60OUL 0.37  130  P2 TWD 14  VH3        -0.84  TEH TEC     23    COLD   60OUL 72  90  0.39  94  P3 TWD 15  DEC        -2.22  TEN TEC    23    COLD  600UL 72  114  0.26  84  P2  TWD 14  VC3        +0.87  TEC TEH     32    HOT   60OUL 72  126  0.44  127 P2  TWD 22  VSM        -0.82  TEC TEH     33    HOT   600UL 0.42  104  P2  TWD 21  VH3        -0.12  TEC TEH    33   HOT   600UL 72  156  0.24  107 P2   TWD 14  VC3        -0.93  TEC TEH    17    HOT    600UL 73  13  0.25  85  P2 TWD 18  VH3        +0.80  TEC TEH    15    HOT    60OUL 73  51  0.30  142 P3   TWD 19  DBH       -1.10  TEC TEH    40    HOT    600UL 73  91  0.47  21  P3  TWD 18  DEC        +2.21  TEH TEC     23    COLD   60OUL 73  157  0.31  131 P2   TWD 17 VH3        +1.09  TEC TEH     17    HOT   600UL 73  163  0.13  44  P3  TWD 6  DEC        +1.54  TEC TEH    21    HOT   60OUL 74  18  0.13  152 P3  TWD 11  DEC        +2.06  TEC TEH     15    HOT   600UL 74  44  0.16  71  P2 TWD 12  VSM        +0.76  TEC TEH    27    HOT    600UL 0.50  133 P2   TWD 27  VH3        -0.80  TEC TEH    27    HOT    60OUL 74  50  0.32 161 P3   TWD 20  DBH        +1.89  TEC TEN    40    HOT     60OUL 74  56  0.23  49  P3  TWD 9  DBH        +0.97  TEC TEH    41    HOT     60OUL 74  90  0.41  123 P3   TWD 21 DEC        -1.75  TEH TEC    24    COLD    600UL 74  94  0.20  35  P3  TWD 12  DBH        -1.63  TEH TEC     22   COLD   60OUL 74  124  0.20  96  P3  TWD 9  DEC        -1.77   TEC TEH      33  HOT    600UL 74  132  0.28  103  P2 TWD 15  VC3       -0.99  TEC TEH      10  HOT    600UL 74  148  0.31 126 P2   TWD 18  VSM        -0.95  TEC TEH      13  HOT    600UL 0.44  55  P2 TWD 22  VH3        -0.93  TEC TEH      13  HOT    600UL 74  156  0.59  46  P2 TWD 26  VC3        -0.76  TEC TEH      18  HOT    600UL 0.41  87  P2 TWD 21  VSM        -0.85  TEC TEH      18  HOT    60OUL 0.57  95  P2 TWD 26  VH3        -0.87  TEC TEH     18  HOT     600UL 75  15  0.10  162  P3 TWD 8  DBH        +1.29  TEC TEH     11  HOT     600UL 75  23  0.14  46  P3 TWD 12  DEC        +1.69  TEC TEH     19  HOT     600UL 75  51  0.15  94  P3 TWD DBH       -2.24  TEC TEH      41  HOT    60OUL 75  53  0.12  91  P1  SCI    TSH        -0.03  TSH TSH      71    HOT    58OPP 75  83  0.51  54  P3  TWO 19   DEC      -2.01    TEN TIC    23    COLD   600UL 75  87  0.51  19  P3  TWD 19  DEC        +2.25    TEH TEC    23    COLD  600UL 0.70  119  P3  TWD 24  DEC        -2.23    TEH TEC     23    COLD  600UL 75  97  0.23  85    P2 TWD 13  VC3        -0.88    TEH TEC    22    COLD  600UL 0.34  105 P2 TWD 18  VC3        +0.90    TEH TEC    22    COLD  60OUL 75  103 0.19  139 P2 TWD 11  VC3        +0.91    TEC TEH     38    HOT   600UL 76  42  0.22  126 P3  TWD 16  DEC      -1.79    TEC TEH     27    HOT   600UL 76  56  0.32  21  P3 TWD 20  DBH       +1.18  TEC TEH    40    HOT    600UL 76  78  0.27  143  P2 TWD 15 VC3        -0.86  TEH TEC     24    COLD   600UL 0.55  125  P2 TWD 25 VC3        +0.86  TEH TEC     24    COLD   600UL 0.26  117  P2 TWD 15 VH3        +0.84  TEH TEC     24    COLD   600UL 76  84  0.37  5    P3 TWD 15  DEC        +2.15  TEI  TEC   23    COLD   60OUL 76  90  0.42  118  P3 TWD 16  DEC        -2.00  TEH TEC    23    COLD    600UL 0.30  33  P3 TWD 12  DBC        +2.15  TEH TEC     23    COLD   600UL 76  114 0.38  78  P2 TWD 19  VH3        -0.87  TEC TEH    32    HOT     600UL 76  138 0.14  14  P3  TWD 8  DEC        +1.93  TEC TEH      9    HOT     600UL
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:
San Onofre -
Unit 2 Component:
S/G 89 Page 12 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: Querytl [2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 107 35 0.25 128 P3 TWD 16 DBC
+2.00 TEC TEH 7
HOT 600UL 107 59 0.32 60 P3 TWD 17 DBH
+1.77 TEH TEC 20 COLD 600UL 107 103 0.51 70 P2 TWD 23 VH2
-0.89 TEH TEC 12 COLD 60OUL 108 42 0.35 104 P3 TWD 13 DBH
+1.86 TEC TEH 8
HOT 60OUL 0.35 127 P3 TWD 13 DBH
-2.25 TEC TEH 8
HOT 60OUL 108 52 1.22 16 2
SAI 06H
+0.67 06H 06H 165 HOT 580PP 108 126 0.33 91 2
SAI 02H
+0.66 02H 02H 174 HOT 580PP 109 47 0.31 130 P2 TWD 17 VSM
-0.58 TEH TEC 22 COLD 600UL 0.29 47 P2 TWD 16 VC3
-0.70 TEH TEC 22 COLD 60OUL 109 55 0.25 133 P3 TWD 14 DBH  
+1.48 TEH TEC 20 COLD 60OUL 110 34 0.28 140 P2 TWD 17 VH2
+0.76 TEC TEH 7
HOT 600UL 110 122 0.30 88 2
SAI 02H
+0.82 02H 02H 174 HOT 580PP 111 43 0.35 95 P2 TWD 21 VH3
-0.95 TEC TEH 8
HOT 60OUL 111 87 0.43 95 P2 TWD 17 VC2
+0.91 TEH TEC 13 COLD 60OUL 11 99 0.47 56 P2 TWD 17 09C
+0.51 TEH TEC 11 COLD 60OUL 112 32 0.32 122 P3 TWD 12 DBC
+1.80 TEC TEH 8
HOT 60OUL 112 134 0.54 97 2
SAI 02H
+0.50 02H 02H 174 HOT 580PP 112 144 0.46 51 P3 TWD 21 DBC
+2.05 TEC TEH 6
HOT 60OUL 113 53 0.24 78 P2 TWD 13 VC2
-0.52 TEH TEC 22 COLD 600UL 113 77 0.31 114 P2 TWO 13 VC3  
+0.92 TEN TEC 13 COLD 6--UL 113 91 0.31 121 P2 TWD 16 VC3
-0.84 TEH TEC 12 COLD 600UL 113 105 0.40 79 P2 TWD 19 VN2
+0.79 TEH TEC 10 COLD 60OUL 0.33 73 P2 TWD 17 VH3
+0.81 TEH TEC 10 COLD 60OUL 113 125 0.23 23 P2 TWD 13 05H
-0.18 TEN TEC 8
COLD 600UL 114 36
* 0.22 76 P2 TWD 13 09C
-1.01 TEC TEH 7
HOT 600UL 0.12 21 P3 TWD 10 DBC
-1.98 TEC TEH 7
HOT 60OUL 114 40 0.35 67 P3 TWD 21 DBH
+1.51 TEC TEH 7
HOT 600UL 114 62 0.32 135 P3 TWD 13 DBH  
-1.77 TEH TEC 19 COLD 60OUL 114 136 0.31 147 P2 TWD 17 VC3
+0.67 TEC TEH 6
HOT 60OUL 115 39 0.75 134 P2 TWD 28 VHI
+0.81 TEC TEH 8
HOT 60OUL 115 43 0.65 144 P2 TWD 26 VHI
+0.83 TEC TEH 8
HOT 60OUL 0.64 161 P2 TWD 25 VH1
-0.70 TEC TEH 8
HOT 60OUL 115 107 0.26 127 P3 TWD 11 DBH  
-1.38 TEH TEC 9
COLD 600UL 116 50 0.25 61 P2 TWD 11 VH2
-1.15 TEH TEC 21 COLD 600UL 116 90 0.47 79 P2 TWD 21 VH1
-1.13 TEH TEC 14 COLD 600UL 116 102 0.64 38 P2 TWD 22 VHN
-0.69 TEH TEC 11 COLD 600UL 116 128 0.46 77 P3 TWD 22 DBH
-1.66 TEH TEC 8
COLD 600UL 116 140 0.24 104 P3 TWD 13 DBH
-1.50 TEC TEH 6
HOT 600UL 117 59 0.37 22 P3 TWD 19 DBH
-1.18 TEH TEC 20 COLD 600UL 117 129 0.42 131 P2 TWD 18 05H
-0.16 TEH TEC 7
COLD 60OUL 118 62 0.41 98 2
SAI 01H
+0.95 01H 01H 171 NOT 580PP 0.25 110 2
SAI 04H
+0.95 04H 04H 171 HOT 58OPP 118 124 0.23 78 2
SAI 02H
+0.43 02H 02H 174 HOT 580PP


AREVA NP Inc                                           1/9/2008 2:18:17 PM Customer Name: San Onofre - Unit   2                 Component: S/G 89                 Page 10 of 16 Post U2C1S Inspection Final Report MAT, MCI, MMI, MVI, SAT, SCI, SVI, 0-100%,     PCS QUERY: QueryMi [2[ .ary ROW LINE VOLTS   DEG CHN IND %TW LOCATION         EXT EXT   CAL # LEG   PROBE 76  142  0.21    91  P2 TWD 13 08C    -0.49  TEC TEH    13    HOT    600UL 76  160  0.43    74  P2 TWD 22  VH3     +0.84  TEC TEH    17    HOT    600UL 77  27  0.24    80  P3  TWD 10  DBC    -1.69  TEC TEH    20    HOT    600UL 77  43  0.30    124 22  TWD 13  VH3    +0.78  TEC TEH    28    HOT    60OUL 77  113  0.18    103 P2   TWD 11  VH3    -1.04  TEC TEH   33    HOT   60OUL 77  137  0.64    98  P2 TWD 26  VSM    -0.90  TEC TEH    10    HOT    60OUL 77  139  0.60    132  P2 TWD 25 VC3    +0.77  TEC TEH  10    HOT    60OUL 0.25    99  P2 TWD 13 VC3    -0.90  TEC TEH   10    HOT   600UL 0.33    61  P2 TWD 17 VSM    -0.92  TEC TEH   10    HOT   600UL 0.31   105  P2 TWD 16 VH3    -1.03  TEC TEH  10    HOT    600UL 77  157  0.38    75  P2 TWD 20  VH3    -0.95  TEC TEH    17    HOT    60OUL 78  26  0.24    130 P2   TWD 18 07C    -0.14   TEC TEH    19    HOT    600UL 78  28  0.07    138 P3  TWD 6  DBC    -1.65  TEC TEH    23    HOT    600UL 78  44  0.33    127 P2  TWD 21  VSM    -0.78  TEC TEH    27    HOT   600UL 78  58  0.24    173 P3   TWD 16  DBH     +1.61  TEC TEH   40    HOT   60OUL 78  130  0.31   132 P2  TWD 15  VSM    -1.02  TEC TEH    10    HOT    60OUL 78  136  0.26    144 P2   TWD 14  VC3    -0.89  STH TEC   38    COLD   600UL 78  150  0.57    64  P2  TWD 24  VH3    -0.74  TEC TEH    14    HOT    60OUL 78  160  0.30    124 P3  TWD 15  DBC    -1.56  TEC TEH    18    HOT    60OUL 79  15  0.13    117 P3   TWD 10 DBH     +1.21  TEC TEN    11    HOT    600UL 79  43  0.23    45  P2 TWD 16  VH3    -0.62  TEC TEH    27    HOT    600UL 79  53  0.57    21  P1  SCI    TSH    -0.02  TSH TSH    71    HOT    580PP 79  79  0.41    143 P2  TWD 16 VH3    -0.92  TEH TEC   23    COLD   600UL 79  89  0.17   108 2    SAI    TSH    +1.00  TSH TSH    53    HOT    58OPP 79  99  0.33    125  P1  SCI    TSH    -0.00  TSH TSH    57    HOT    580PP 80  72  0.20    88  P3 TWD 15  DBH     -2.24  TEC TEH    44    HOT    600UL 80  106  0.29    78  P2  TWD 16  VH3    +0.91  TEC TEH    32    HOT    600UL 80  152  0.59    108  P2 TWD 27 VC3    +0.86  TEC TEH  13    HOT    60OUL 0.67    105  P2 TWD 29 VC3    -0.80  TEC TEH  13    HOT    600UL 0.33   123  P2 TWD 18 VSM    +0.86  TEC TEH  13    HOT    600UL 0.52    137  P2 TWD 25 VSM    -0.82    TEC TEH  13    HOT    600UL 80  160 0.63    117 P3 TWD 27  DBC    -1.59    TEC TEH   17  HOT    600UL TEC TEN    11    NOT    600UL 81  21  0.15    87  P3  TWD 12  DBE    +0.78 TEC TEH    11  HOT     600UL 81  25  0.13    158  P3 TWD 10  DBC    -1.38 TEN TEC   17   COLD   600UL 81  75  0.34    125 22  TWD 17  VC3    +0.86 TEN TEC   17   COLD   600UL 0.27    24  P3  TWD 13  DBH TEH TEC   13  COLD   60OUL 81  79  0.94    100  P2 TWD 30  VH3              TEH TEC   13  COLD   60OUL 0.37    124  P2 TWD 15  VC 3 TEN TEC    9    COLD    6000L 81  105 0.55    148  ?2 TWD 21  VH3    +0.99    TEH TEC   9    COLD   600UL 0.29    114  P2 TWD 12  VSM      +0.87 TEC TEN    5    NOT    600UL 81  135 0.41    123  P2 TWD 20  VH3    +0.92 TEC TEN    S    NOT D  60UL 0.24    157  P2 TWD 14 VH3      -0.73 TEC TEH    9    HOT    60OUL 81  159 0.33    72  P2 TWD 17 VH3      -0.87 TEC TEH    9    POT    600UL 0.26     87  P2  TWD 14  02H    -0.36 600UL - -- --
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -
82  28  0.20    92  P2  TWD 16 VH3      -0.19  TEC TEH    11    HOT    600UL 0.23    99  22  TWD 18 VH3      -0.68  TEC TEH    11  HOT
Unit 2 Component:
S/G 89 Page 13 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 118 128 0.29 101 P2 TWD 13 05H
+0.70 TEH TEC 7
COLD 600UL 119 79 0.68 132 P2 TWD 24 VH3  
+0.86 TEH TEC 13 COLD 600UL 119 119 0.42 30 P2 TWD 18 10H
-1.08 TEH TEC 7
COLD 600UL 119 121 0.53 98 P2 TWD 21 10H
-1.20 TEH TEC 7
COLD 60OUL 120 38 0.23 66 P2 TWD 15 10H
+1.05 TEC TEH 8
HOT 600UL 120 72 0.23 61 P2 TWD 13 10H
-1.02 TEH TEC 17 COLD 600UL 120 98 0.48 80 P2 TWD 23 VHl
-0.80 TEH TEC 12 COLD 600UL 121 39 0.27 100 P2 TWD 17 10H
-1.44 TEC TEH 8
HOT 600UL 121 45 0.62 108 P2 TWD 29 VC2
-0.62 TEC TEH 8
HOT 60OUL 121 47 0.31 113 P2 TWD 16 10H
+0.76 TEH TEC 22 COLD 600UL 121 83 0.53 125 P2 TWD 23 VC3
-0.88 TEH TEC 14 COLD 60OUL 0.38 134 P2 TWD 18 VHl
+0.84 TEH TEC 14 COLD 60OUL 121 109 0.87 88 P2 TWD 31 10H
-1.50 TEH TEC 10 COLD 600UL 122 110 0.23 102 2 SAI 05H
-0.30 05H 05H 174 HOT 58OPP 123 45 0.29 17 P3 TWD 18 DBH  
+2.02 TEC TEH 7
HOT 600UL 123 117 0.31 141 23 TWD 12 DBH
-1.90 TEH TEC 9
COLD 600UL 124 58 0.54 128 P2 TWD 24 VHl
-0.78 TEH TEC 20 COLD 600UL 124 98 0.26 7
P3 TWD 14 DBH
+1.86 TEH TEC 12 COLD 60OUL 125 53 0.31 133 P2 TWD 17 VHl
-0.79 TEH TEC 22 COLD 600UL 125 55 0.21 117 P3 TWD 12 DBH  
+1.69 TEH TEC 20 COLD 600UL 125 77 0.42 128 P2 TWD 20 VHl
+0.92 TEH TEC 14 COLD 600UL 125 111 0.25 168 P3 TWD 14 DBH
+1.69 TEH TEC 10 COLD 600UL 125 119 0.30 109 P3 TWD 16 DBH
+1.62 TEH TEC 8
COLD 60OUL 126 74 0.31 84 P2 TWD 17 VHl
-1.06 TEH TEC 17 COLD 60OUL 126 86 0.24 110 P3 TWD 9 DBH
-1.90 TEH TEC 13 COLD 600UL 126 102 0.26 24 P3 TWD 14 DBH  
-1.26 TEH TEC 12 COLD 600UL 126 108 0.27 162 P3 TWD 11 DBH
-1.64 TEH TEC 9
COLD 600UL 127 71 0.41 142 P2 TWD 20 04H
+0.89 TEH TEC 17 COLD 600UL 127 99 0.39 151 P2 TWD 15 VHl
+0.84 TEH TEC 11 COLD 600UL 127 111 0.33 25 P2 TWD 14 04H
+0.20 TEH TEC 9
COLD 600UL 127 123 0.34 97 P2 TWD 15 09C
-1.20 TEH TEC 7
COLD 60OUL 128 56 0.23 168 P3 TWD 10 DBH
+2.04 TEH TEC 19 COLD 600UL 128 60 0.42 95 2
SAI 04H
+0.75 04H 04H 166 HOT 580PP 128 72 0.32 92 P2 TWD 17 10H
+0.94 TEH TEC 17 COLD 600UL 0.61 120 P2 TWD 26 10H
+0.08 TEH TEC 17 COLD 600UL 0.69 144 P2 TWD 28 iOH
-1.19 TEH TEC 17 COLD 600UL 128 92 0.52 43 22 TWO 19 06H
+0.93 TEN TEC i1 COLD 60OUL 129 47 0.48 141 P2. TWD 23 10H
+0.83 TEH TEC 22 COLD 600UL 0.42 130 P3 TWD 22 DBH
+1.67 TEH TEC 22 COLD 600UL 0.39 47 P3 TWD 21 DBH
-1.32 TEH TEC 22 COLD 600UL 129 49 0.44 90 P2 TWD 21 VHI
-0.83 TEH TEC 22 COLD 600UL 0.32 90 P2 TWD 17 VHi
+0.91 TEH TEC 22 COLD 600UL 129 73 0.26 65 P3 TWO 16 DEN
+1.92 TEN TIC 18 COLD SOQUL--------------------
129 73 0.26 65 P3 TWD 16 DBE
+1.92 TEH TEC 18 COLD 600UL


AREVA NP Inc                                             1/9/2008 2:18:17 PM Customer Name: San Onofre - Unit 2                       Component: S/G 89         Page 11 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,     0-100%,   PCS QUERY:   QueryMl[2].qry ROW LINE VOLTS   DEG CHN IND %TW LOCATION           EXT EXT   CAL # LEG   PROBE 82  44    0.22  138  P2 TWD 13  VH3        +0.91  TEC TER    7    HOT    600UL 82  68    0.42  140 P2   TWD 20  VH3       +0.86   TEH TEC   17    COLD   600UL 0.89  127 P2   TWD 32  VH3        -0.86  TEM TEC   17    COLD   60OUL 82  148  0.61  125 P2   TWD 26  VH3        -0.89  TEC TEH    9    HOT    600UL 83  73    0.29  111 2    SAI    03H        -0.11  03H 03H    171  HOT    580PP 84  40    0.38  64  P2 TWD 22  VH2       -1.14   TEC TEH    8    HOT    600UL 84  100  0.47  66  P2 TWD 22  09H        -1.59  TEH TEC   12    COLD   60OUL 84  108  0.40  127  P2 TWD 19  09H        +0.39  TEH TEC   10    COLD   600UL 85  81    0.31  102  P1  SCI    TSH        +0.19  TSH TSH    107  HOT    580PP 85  91    0.25  93  P3  TWD 9  DBC        -1.85  TEN TEC    11    COLD  60OUL 86  68    0.37   42  P2 TWD 19 VH2        +0.82  TEN TEC   17   COLD   60OUL 86  130   0.37  114  P2 TWD 19  VH2        -0.77  TEC TEH    5    HOT    600UL 87  31    0.82   19  2   SAI     05H        +0.33  05H 05H    143  HOT   580PP 87  47    0.18  105  2  SAT    03H        -0.21  03H 03H    165  HOT    58OPP 87   131  0.35  122  P2 TWD 18  VH2        +0.66  TEC TEH    5    HOT    600UL 88  40    0.23  76  P2 TWD 14  VSM        -0.93  TEC TEH    8    HOT    60OUL 89  25    0.14  36  P3 TWD 11  DBH       +0.04  TEC TEH    11  HOT    600UL 89  93    0.48  17  2  SAI    TSH        -13.00  TSH TSH    113  HOT    580PP 90  122  0.38  140  P2 TWD 19  VH2        -0.78  TEN TEC     8    COLD   60OUL 91  85    0.33  104  2  SAI    03H        +0.20  03H 03H    176  HOT    580PP 93  113  0.35  67  2  SAT    02H        +0.84  02H 02H    174  HOT    580PP 94  22    0.23  93  P2 TWD 11  02C        +0.93  TEC TEN    12  HOT    60OUL 94  50    0.33  133  P2 TWD 14  05C        -0.12  TEN TEC     21  COLD   60OUL 94  146  0.23    124 P2 TWD 14  VH3        -0.96  TEC TER    5    HOT    600UL 97  37    0.50    115 P2 TWD 26  VC3        +0.95  TEC TEH     8    HOT    600UL 98  62    1.26  20  2   SAI    TSH        -13.92  TSH TSH    101  HOT    580PP 98  82    0.31    100 2    SAI    01H        -0.44    01H 01H    176  HOT   58OPP 99  131  0.30    124 P2  TWD 16 VH2        +0.73  TEC TEH    5    HOT    600UL 101 25    0.33    118 P2 TWD 15  08H        +0.47    TEC TEN    12    HOT    600UL 101 33    0.20    20  P3  TWD 12  DBC        +2.00    TEC TEN    7    HOT    600UL 101  39  0.32    99  P2  TWD 19  VH2        +0.85   TEC TEH    8    HOT    600UL 101 143  0.24    121  P3 TWD 15  DBH       +1.84    TEC TEH    5    HOT    600UL 102 58    0.38    124 P2 TWD 16 VH3        +0.86    TEN TEC   19    COLD   600UL 0.25    109 P2 TWD 11 VC3        +0.86    TEN TEC   19    COLD   60OUL 0.21    150 P2  TWD 10 VC3        -0.82    TEH TEC   19    COLD   600UL 0.25    125 P2 TWD 11 VC2        -0.89  TEN TEC   19    COLD   60OUL 103 137  0.39    92  P2 TWD 20  VH3        -0.92  TEC TEH    6    HOT    60OUL 105 61    0.20    141  P2 TWD 11 VC3        -0.80  TEN TEC   20    COLD   600UL 105 141  0.19    148  P3 TWD 12 DBH        +1.78  TEC TEN    5    HOT    600UL 106 84    0.34    120  P2 TWD 15 VH3        +0.80  TEH TEC   13   COLD   600UL 106 126  0.44    94  2  MAI    02H        +0.24  02H 02H    174  HOT    580P?
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:
107  33  0.21    38  P3  TWD 16  DBC        +1.65  TEC TER    7    HOT    60OUL
San Onofre -
Unit 2 Component: S/G 89 Page 14 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MVI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMi[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE
------------------------------------------------------==-------------------=--=----------------
129 89 0.27 60 P2 TWD 14 VH2
-0.88 TEH TEC 14 COLD 600UL 0.23 154 P2 TWD 12 VH3  
-0.86 TEH TEC 14 COLD 600UL 0.24 87 P2 TWD 12 VC3
-1.07 TEH TEC 14 COLD 60OUL 0.23 76 P2 TWD 12 VC3
+0.82 TEH TEC 14 COLD 600UL 0.26 100 P2 TWD 14 VH2  
+0.88 TEH TEC 14 COLD 600UL 129 109 0.43 139 P2 TWD 20 10H
-1.05 TEH TEC 10 COLD 60OUL 130 48 0.35 68 P2 TWD 18 02C
-0.18 TEH TEC 22 COLD 600UL 130 74 0.37 99 P2 TWD 19 10H
+0.96 TEH TEC 17 COLD 600UL 130 78 0.30 93 P2 TWD 12 10H
-1.22 TEH TEC 13 COLD 600UL 130 82 0.67 82 2
SAI 01H
-0.27 01H 01H 176 HOT 580PP 130 86 0.50 111 P2 TWD 20 VHN
+0.87 TEH TEC 13 COLD 60OUL 130 88 0.46 109 P2 TWD 22 VH1
-0.88 TEH TEC 14 COLD 600UL 132 56 0.62 131 P2 TWD 26 VHN
-1.02 TEH TEC 17 COLD 600UL 132 74 0.30 108 P3 TWD 14 DBH  
+1.70 TEH TEC 17 COLD 600UL 132 106 0.71 125 P2 TWD 26 10H
-1.09 TEH TEC 15 COLD 60OUL 133 55 0.28 75 P2 TWD 15 02H
+0.22 TEH TEC 17 COLD 60OUL 133 81 0.58 130 P2 TWD 23 VHN
+0.90 TEH TEC 15 COLD 60OUL 133 119 0.57 114 P2 TWD 24 VHN
+0.92 TEH TEC 16 COLD 600UL 133 125 0.35 91 P2 TWD 17 01C
+0.88 TEH TEC 16 COLD 60OUL 134 64 0.31 98 P2 TWD 16 VH3
-0.90 TEH TEC 18 COLD 600UL 0.34 139 P2 TWD 17 VC3
-0.84 TEH TEC 18 COLD 600UL 134 76 0.39 78 P2 TWD 18 VHN
-0.86 TEH TEC 16 COLD 600UL 0.28 11 P3 TWD 14 DBH
+2.19 TEH TEC 16 COLD 600UL 134 80 0.29 6
P3 TWD 15 DBH
+2.04 TEH TEC 16 COLD 600UL 134 124 0.23 119 P2 TWD 12 VC3
+0.65 01C TEH 132 HOT 60OUL 135 67 0.34 84 P3 TWD 16 DBH
-1.62 TEH TEC 17 COLD 60OUL 135 71 0.23 161 P3 TWD 14 DBH
-1.80 TEH TEC 18 COLD 600UL 136 68 0.54 111 P2 TWD 24 VHN
-0.88 TEH TEC 17 COLD 600UL 0.33 95 P2 TWD 17 VH1
-1.13 TEH TEC 17 COLD 600UL 136 76 0.27 9
23 TWD 14 DBH
+1.85 TEH TEC 16 COLD 600UL 136 78 0.23 123 P3 TWD 12 DBH  
+1.79 TEH TEC 16 COLD 600UL 0.31 48 P2 TWD 15 VH1
+0.72 TEH TEC 16 COLD 600UL 137 69 0.37 82 P2 TWD 19 VHN
+0.55 TEH TEC 17 COLD 600UL 137 71 0.45 48 P3 TWD 19 DBH
-1.64 TEH TEC 17 COLD 600UL 137 117 0.32 140 P3 TWD 16 DBH
+1.67 TEH TEC 16 COLD 600UL 0.40 115 P2 TWD 18 VHN
-0.82 TEN TEC 16 COLD 60OUL 138 58 0.44 69 P3 TWD 23 DBH
+1.87 TEH TEC 18 COLD 60OUL 138 64 0.27 101 P2 TWD 14 10H
+0.80 TEH TEC 18 COLD 600UL 138 80 0.40 70 P2 TWD 18 VHi
-0.86 TEH TEC 16 COLD 600UL 138 96 0.23 149 P3 TWD 12 DBC
+1.13 TEH TEC 16 COLD 600UL 138 102 0.44 97 P2 TWD 20 VHI
-0.86 TEH TEC 16 COLD 60OUL 139 61 0.24 104 P2 TWD 13 09C
-1.09 TEH TEC 18 COLD 600UL 139 65 0.31 95 P2 TWD 17 VH!
+0.88 TEH TEC 17 COLD 600UL 139 103 0.62 138 22 TWD 24 VH2
+0.84 TEH TEC 15 COLD 600UL


AREVA NP Inc                                                 1/9/2008 2:18:17 PM Customer Name:     San Onofre - Unit 2                       Component: S/G 89           Page 12 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,         0-100%,   PCS QUERY:   Querytl [2] .qry ROW LINE VOLTS       DEG CHN IND %TW LOCATION           EXT EXT     CAL # LEG   PROBE 107 35      0.25    128 P3  TWD 16  DBC      +2.00  TEC TEH    7    HOT    600UL 107 59      0.32    60  P3  TWD 17  DBH      +1.77  TEH TEC    20    COLD  600UL 107 103    0.51    70  P2  TWD 23  VH2      -0.89  TEH TEC    12    COLD  60OUL 108 42      0.35    104  P3  TWD 13  DBH      +1.86  TEC TEH    8    HOT    60OUL 0.35    127  P3  TWD 13  DBH      -2.25  TEC TEH    8    HOT    60OUL 108 52      1.22    16  2  SAI      06H      +0.67  06H 06H    165  HOT    580PP 108  126  0.33    91  2  SAI      02H      +0.66  02H 02H    174  HOT    580PP 109 47      0.31    130  P2  TWD 17  VSM      -0.58  TEH TEC    22    COLD  600UL 0.29    47  P2  TWD 16  VC3      -0.70  TEH TEC    22    COLD  60OUL 109 55      0.25    133  P3  TWD 14  DBH      +1.48  TEH TEC    20    COLD  60OUL 110 34      0.28    140  P2  TWD 17  VH2      +0.76  TEC TEH    7    HOT    600UL 110  122  0.30    88  2  SAI      02H      +0.82  02H 02H    174  HOT    580PP 111  43    0.35    95  P2  TWD 21  VH3      -0.95  TEC TEH    8    HOT    60OUL 111  87    0.43    95  P2  TWD 17  VC2      +0.91  TEH TEC    13    COLD  60OUL 11    99    0.47    56  P2  TWD 17  09C      +0.51  TEH TEC    11    COLD  60OUL 112  32    0.32    122  P3  TWD 12  DBC      +1.80  TEC TEH    8    HOT    60OUL 112  134  0.54    97  2  SAI      02H      +0.50    02H 02H    174  HOT    580PP 112 144    0.46    51  P3  TWD 21  DBC      +2.05  TEC TEH    6    HOT    60OUL 113 53    0.24    78  P2  TWD 13  VC2      -0.52  TEH TEC    22    COLD    600UL 113  77    0.31    114 P2  TWO 13  VC3      +0.92  TEN TEC    13    COLD    6--UL 113 91    0.31    121 P2  TWD 16  VC3      -0.84    TEH TEC    12    COLD    600UL 113  105  0.40    79  P2  TWD 19  VN2      +0.79    TEH TEC    10    COLD    60OUL 0.33    73  P2  TWD 17  VH3      +0.81    TEH TEC    10  COLD    60OUL 113 125    0.23    23  P2  TWD 13  05H      -0.18    TEN TEC    8    COLD    600UL 114 36
AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:
* 0.22      76    P2 TWD 13  09C      -1.01    TEC TEH    7    HOT    600UL 0.12    21    P3 TWD 10  DBC        -1.98  TEC TEH    7    HOT    60OUL 114  40    0.35    67    P3  TWD 21  DBH        +1.51  TEC TEH    7    HOT    600UL 114  62    0.32    135  P3  TWD 13  DBH        -1.77  TEH TEC    19  COLD    60OUL 114  136  0.31    147  P2  TWD 17  VC3        +0.67  TEC TEH    6    HOT    60OUL 115  39    0.75    134  P2  TWD 28  VHI        +0.81  TEC TEH    8    HOT    60OUL 115 43    0.65      144 P2  TWD 26  VHI        +0.83  TEC TEH    8    HOT    60OUL 0.64      161 P2  TWD 25  VH1        -0.70  TEC TEH    8    HOT    60OUL 115 107    0.26      127 P3  TWD 11  DBH        -1.38  TEH TEC      9    COLD  600UL 116 50    0.25      61  P2  TWD 11  VH2        -1.15  TEH TEC    21    COLD  600UL 116 90    0.47      79  P2  TWD 21  VH1        -1.13  TEH TEC      14  COLD  600UL 116 102    0.64      38  P2  TWD 22  VHN        -0.69  TEH TEC      11  COLD  600UL 116 128    0.46      77  P3  TWD 22  DBH      -1.66  TEH TEC      8    COLD  600UL 116 140    0.24    104  P3  TWD 13  DBH      -1.50  TEC TEH      6    HOT    600UL 117  59    0.37    22  P3  TWD 19  DBH      -1.18  TEH TEC      20  COLD    600UL 117  129  0.42    131  P2  TWD  18  05H      -0.16  TEH TEC      7    COLD    60OUL 118  62    0.41    98  2  SAI      01H      +0.95  01H 01H      171  NOT    580PP 0.25    110  2  SAI      04H      +0.95  04H 04H      171  HOT    58OPP 118 124    0.23    78  2  SAI      02H      +0.43    02H 02H    174  HOT    580PP
San Onofre -
Unit 2 Component: S/G 89 Page 15 of 16 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVI,
: SAI, SCI,
: SVI, 0-100%,
PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE


AREVA NP Inc                                                1/9/2008 2:18:17 PM Customer Name:    San Onofre - Unit 2                      Component: S/G 89                              Page 13 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,        0-100%,  PCS QUERY:    QueryMl[2] .qry ROW LINE VOLTS      DEG CHN IND %TW LOCATION            EXT EXT    CAL # LEG    PROBE 118 128    0.29    101 P2    TWD 13  05H      +0.70  TEH TEC    7    COLD  600UL 119 79      0.68    132 P2    TWD 24  VH3      +0.86  TEH TEC    13    COLD  600UL 119 119    0.42    30  P2  TWD 18  10H      -1.08  TEH TEC    7    COLD  600UL 119 121    0.53    98  P2  TWD 21  10H      -1.20  TEH TEC    7    COLD  60OUL 120 38      0.23    66  P2  TWD 15  10H      +1.05  TEC TEH    8    HOT    600UL 120 72      0.23    61  P2  TWD 13  10H      -1.02  TEH TEC    17    COLD  600UL 120 98      0.48    80  P2  TWD 23  VHl      -0.80  TEH TEC    12    COLD  600UL 121 39      0.27    100  P2  TWD 17  10H      -1.44  TEC TEH    8    HOT    600UL 121 45      0.62    108  P2  TWD 29  VC2      -0.62  TEC TEH    8    HOT    60OUL 121 47      0.31    113  P2  TWD 16  10H      +0.76  TEH TEC    22    COLD    600UL 121 83      0.53    125  P2  TWD 23  VC3      -0.88  TEH TEC    14    COLD    60OUL 0.38    134  P2  TWD 18  VHl      +0.84  TEH TEC    14    COLD    60OUL 121 109    0.87    88  P2  TWD 31  10H      -1.50  TEH TEC    10    COLD    600UL 122  110  0.23    102  2    SAI    05H      -0.30  05H 05H    174  HOT    58OPP 123  45    0.29    17  P3  TWD 18  DBH      +2.02  TEC TEH    7    HOT    600UL 123  117  0.31    141 23    TWD 12  DBH      -1.90  TEH TEC    9    COLD    600UL 124  58    0.54    128  P2  TWD 24  VHl      -0.78  TEH TEC    20    COLD    600UL 124  98    0.26    7    P3  TWD 14  DBH      +1.86  TEH TEC    12    COLD    60OUL 125 53    0.31    133 P2    TWD 17  VHl      -0.79  TEH TEC    22    COLD    600UL 125 55    0.21    117 P3    TWD 12  DBH      +1.69  TEH TEC    20    COLD    600UL 125 77    0.42    128 P2    TWD 20 VHl      +0.92  TEH TEC    14    COLD    600UL 125 111    0.25    168 P3    TWD 14  DBH      +1.69  TEH TEC    10    COLD    600UL 125 119    0.30    109 P3    TWD 16  DBH      +1.62  TEH TEC    8    COLD    60OUL 126 74    0.31    84    P2  TWD 17 VHl        -1.06  TEH TEC    17    COLD    60OUL 126 86    0.24    110  P3  TWD 9  DBH      -1.90  TEH TEC    13  COLD    600UL 126  102  0.26    24    P3  TWD 14  DBH      -1.26  TEH TEC    12  COLD    600UL 126 108    0.27    162  P3  TWD 11  DBH      -1.64  TEH TEC    9    COLD    600UL 127 71    0.41    142  P2  TWD 20  04H      +0.89  TEH TEC    17  COLD    600UL 127 99    0.39    151  P2  TWD 15  VHl      +0.84  TEH TEC    11  COLD    600UL 127 111    0.33    25    P2  TWD 14  04H      +0.20  TEH TEC    9    COLD    600UL 127 123    0.34    97  P2  TWD 15  09C      -1.20  TEH TEC    7    COLD    60OUL 128 56    0.23    168 P3    TWD 10  DBH      +2.04  TEH TEC    19    COLD    600UL 128  60  0.42    95  2    SAI    04H      +0.75  04H 04H    166  HOT    580PP 128  72  0.32    92  P2  TWD 17  10H      +0.94  TEH TEC    17    COLD    600UL 0.61    120  P2  TWD 26  10H      +0.08  TEH TEC    17  COLD    600UL 0.69    144  P2  TWD 28  iOH      -1.19  TEH TEC    17  COLD    600UL 128 92    0.52    43  22  TWO 19  06H      +0.93  TEN TEC    i1  COLD    60OUL 129 47    0.48    141  P2. TWD 23  10H      +0.83  TEH TEC    22  COLD    600UL 0.42    130  P3 TWD 22    DBH      +1.67  TEH TEC    22  COLD    600UL 0.39    47  P3 TWD 21    DBH      -1.32  TEH TEC    22  COLD    600UL 129 49    0.44    90  P2  TWD 21  VHI      -0.83  TEH TEC    22  COLD    600UL 0.32    90  P2  TWD 17  VHi      +0.91  TEH TEC    22  COLD    600UL 129 73    0.26    65  P3  TWO 16  DEN      +1.92  TEN TIC    18  COLD    SOQUL--------------------
===========--  
129 73    0.26    65  P3  TWD 16  DBE      +1.92  TEH TEC    18  COLD    600UL


AREVA NP Inc                                                  1/9/2008 2:18:17 PM Customer Name:    San Onofre - Unit 2                          Component: S/G 89                Page 14 of 16 Post U2C15 Inspection Final Report MAI, MCI, MVI, MVI, SAI, SCI, SVI,      0-100%,  PCS QUERY:    QueryMi[2].qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION                EXT EXT    CAL # LEG    PROBE
=== =--  
------------------------------------------------------==-------------------=--=----------------
-:===========================  
129 89      0.27  60  P2  TWD  14 VH2        -0.88      TEH  TEC  14    COLD  600UL 0.23  154  P2  TWD  12 VH3        -0.86      TEH  TEC  14    COLD  600UL 0.24  87  P2  TWD  12 VC3        -1.07      TEH  TEC  14    COLD  60OUL 0.23  76  P2  TWD  12 VC3        +0.82      TEH  TEC  14    COLD  600UL 0.26  100  P2  TWD  14 VH2        +0.88      TEH  TEC  14    COLD  600UL 129  109  0.43  139  P2  TWD 20  10H        -1.05      TEH TEC    10    COLD  60OUL 130  48    0.35  68  P2  TWD 18  02C        -0.18      TEH TEC    22    COLD  600UL 130 74      0.37  99  P2  TWD 19  10H        +0.96      TEH TEC    17    COLD  600UL 130 78      0.30  93  P2  TWD 12  10H        -1.22      TEH TEC    13    COLD  600UL 130 82      0.67  82  2  SAI    01H        -0.27      01H 01H    176  HOT    580PP 130 86      0.50  111  P2  TWD 20  VHN        +0.87      TEH TEC    13    COLD  60OUL 130  88    0.46  109 P2  TWD 22  VH1        -0.88      TEH TEC    14    COLD  600UL 132  56    0.62  131  P2  TWD 26  VHN        -1.02      TEH TEC    17    COLD  600UL 132 74    0.30  108 P3  TWD 14  DBH        +1.70      TEH TEC    17    COLD  600UL 132 106    0.71  125 P2  TWD 26  10H        -1.09      TEH TEC    15    COLD  60OUL 133 55    0.28  75  P2  TWD 15  02H        +0.22      TEH TEC    17    COLD  60OUL 133 81    0.58  130 P2  TWD 23  VHN        +0.90      TEH TEC    15    COLD  60OUL 133 119    0.57  114 P2  TWD 24  VHN        +0.92      TEH TEC    16    COLD  600UL 133 125    0.35  91  P2  TWD 17  01C        +0.88      TEH TEC    16    COLD  60OUL 134 64    0.31  98  P2  TWD 16  VH3        -0.90      TEH TEC    18    COLD  600UL 0.34  139 P2  TWD 17  VC3        -0.84      TEH TEC    18    COLD  600UL 134 76    0.39  78  P2  TWD 18  VHN        -0.86      TEH TEC    16    COLD  600UL 0.28  11    P3 TWD 14  DBH        +2.19      TEH TEC    16    COLD  600UL 134 80    0.29  6    P3  TWD 15  DBH        +2.04      TEH TEC    16    COLD  600UL 134  124  0.23  119  P2 TWD 12  VC3        +0.65      01C TEH    132  HOT    60OUL 135  67    0.34  84    P3 TWD 16  DBH        -1.62      TEH TEC    17    COLD  60OUL 135 71    0.23  161  P3 TWD 14  DBH        -1.80      TEH TEC    18    COLD  600UL 136 68    0.54  111  P2 TWD 24  VHN        -0.88      TEH TEC    17    COLD  600UL 0.33  95    P2 TWD 17  VH1        -1.13      TEH TEC    17    COLD  600UL 136 76    0.27  9    23 TWD 14  DBH        +1.85      TEH TEC    16    COLD  600UL 136 78    0.23  123  P3 TWD 12  DBH        +1.79      TEH TEC    16    COLD  600UL 0.31  48    P2 TWD 15  VH1        +0.72      TEH TEC    16    COLD  600UL 137 69    0.37  82    P2 TWD 19  VHN        +0.55      TEH TEC    17    COLD  600UL 137 71      0.45  48  P3 TWD 19  DBH      -1.64        TEH TEC    17    COLD  600UL 137  117  0.32  140 P3  TWD 16  DBH        +1.67      TEH TEC    16    COLD  600UL 0.40  115 P2  TWD 18  VHN        -0.82        TEN TEC    16    COLD  60OUL 138  58    0.44  69  P3 TWD 23  DBH      +1.87        TEH TEC    18    COLD  60OUL 138  64    0.27  101 P2  TWD 14  10H      +0.80        TEH TEC    18    COLD  600UL 138  80    0.40  70  P2 TWD 18  VHi        -0.86        TEH TEC    16    COLD  600UL 138 96    0.23  149 P3  TWD 12  DBC      +1.13        TEH TEC    16    COLD  600UL 138 102    0.44  97  P2  TWD 20  VHI        -0.86      TEH TEC    16    COLD    60OUL 139 61    0.24  104  P2  TWD 13  09C        -1.09      TEH TEC    18    COLD    600UL 139 65    0.31  95  P2  TWD 17  VH!        +0.88      TEH TEC    17    COLD    600UL 139 103    0.62  138  22  TWD 24  VH2        +0.84      TEH TEC    15    COLD    600UL


AREVA NP Inc                                                    1/9/2008 2:18:17 PM Customer Name:    San Onofre - Unit 2                            Component: S/G 89                    Page 15 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVI, SAI, SCI, SVI,      0-100%,    PCS QUERY:  QueryMl[2].qry ROW LINE VOLTS    DEG CHN IND %TW LOCATION                  EXT EXT CAL # LEG        PROBE
=== - -----=======:=====  
=== ==== ====--    === =--  -: === ======================== ===- ----- ==== ===:===== = ------------
= ------------
139 115   0.23   158 P3   TWD 12 DBH       +1.64         TEH TEC   16   COLD     60OUL 140 66     0.16   148 P3 TWD 8   DBH       +1.87         TEH TEC   17   COLD     60OUL 140 90     0.45   69   P2 TWD 20 VHl       -0.84         TEH TEC   16   COLD     60OUL 140 112   0.22   7   P3 TWD 12 DBC       +1.61         TEH TEC   16   COLD     60OUL 141 67     0.31   71   P2 TWD 16 09C       -1.07         TEH TEC   18   COLD     60OUL 141 83     0.24   136 P3 TWD 12 DBH       +1.80         TEH TEC   16   COLD     600UL 141 89     0.37   114 P2 TWD 18 VHl       -0.66         TEH TEC   16   COLD     600UL 141 103   0.23   31   P3 TWD 12 DBH       +2.02         TEH TEC   16   COLD     600UL 0.26   31   P2 TWD 13 VH3       -0.90         TEH TEC   16   COLD     600UL 0.26   83   P2 TWD 13 VH3       +0.88         TEH TEC   16   COLD     600UL 141 109   0.54   88   P2 TWD 22 VH3       +0.00         TEH TEC   15   COLD     60OUL 142 72     0.56   92   P3 TWD 27 DBC       +2.05         TEH TEC   18   COLD     600UL 142 92   0.51   106 P2   TWD 22 VHl       -0.88         TEH TEC   16   COLD     600UL 143 71     0.74   105 P2 TWD 29 VHl       -0.86         TEH TEC   18   COLD     60OUL 0.53   81   P2 TWD 24 VHl       +0.53         TEH TEC   18   COLD     600UL 0.45   126 P2 TWD 21 VHI       +0.86         TEH TEC   18   COLD     600UL 0.32   108 P2 TWD 16 VH2       -0.86         TEH TEC   18   COLD     600UL 0.57   108 P3 TWD 27 DOH       +2.17         TEH TEC   18   COLD     60OUL 143 75   0.30   151 P3   TWD 18 DBC       -1.68         TEH TEC   18   COLD     600UL 143 81   0.28   75   P2 TWD 14 VC1       -0.78         TEH TEC   16   COLD     600UL 143 85   0.24   99   P3 TWD 13 DBC       +1.32         TEH TEC   16   COLD     600UL 143 87   0.34   131 P2   TWD 15 10C       +0.88         TEH TEC   15   COLD     600UL 0.59   61   P3 TWD 21 DBC       +1.87         TEH TEC   15   COLD     600UL 0.26   53   P3 TWD 8   DBC       -1.99         TEH TEC   15   COLD     600UL 143 91   0.19   52   P3 TWD 11 DBH       +1.52         TEH TEC   16   COLD     600UL 143 105   0.22   166 P3   TWD 12 DBH       +1.81         TEH TEC   16   COLD     600UL 143 107   0.22   18   P3 TWD 12 DBH       -1.26         TEH TEC   16   COLD     60OUL 143 109   0.67   102 P3   TWD 27 DBC       -1.93         TEH TEC   16   COLD     600UL 144 78   0.25   148 P2   TWD 13 VC1       +0.82         TEH TEC     18   COLD     600UL 144 84   0.32   124 P3 TWD 13 DBC       -1.86         TEH TEC     15   COLD     60OUL 0.19   17   P3 TWD 8   DBC       +1.89         TEH TEC     15   COLD     60OUL 144 90   0.19   95   P2 TWD 10 VHI       -0.98         TEH TEC     16   COLD     600UL 144 102   0.26   71   P3 TWD 14 DBH       -1.64         TEH TEC     16   COLD     600UL 145 77   0.15   150 P3 TWD 10 DBH       -1.80         TEH TEC     18   COLD     60OUL 145 89   0.27   147 P3 TWD 14 DBH       +1.91         TEH TEC     16   COLD     600UL 0.44   84   P2 TWD 20 VC2       +0.90         TEH TEC     16   COLD     600UL 145 99   0.40     97 P3 TWD 19 DOH       +2.10         TEH TEC     16   COLD     60OUL 145 103   0.67     116 P3 TWD 27 DBH       +1.69         TEH TEC     16   COLD     600UL 146 76   0.28   78   P3 TWD 17 DBH       +2.17         TEH TEC     18   COLD     60OUL 146 78   0.50     96 P3 TWD 25 DBH       +1.84         TEE TEC     18   COLD     600UL 0.42     144 P3 TWD 23 DBC       +1.67         TEH TEC     18   COLD     60OUL 0.25     150 P3 TWD 15 DBC       -1.65         TEH TEC     18   COLD     600UL 146 80   0.26     145 P3 TWD 16 DBC       +1.62         TEH TEC   18   COLD     600UL 0.32   24   P3 TWD 19 DBH       +1.88         TEH TEC     18   COLD     600UL 146 88   0.51     55   P3 TWD 23 DBC       +1.64         TEH TEC   16   COLD     600UL Total Tubes   : 492 Total Records: 624
139 115 0.23 158 P3 TWD 12 DBH  
+1.64 TEH TEC 16 COLD 60OUL 140 66 0.16 148 P3 TWD 8 DBH  
+1.87 TEH TEC 17 COLD 60OUL 140 90 0.45 69 P2 TWD 20 VHl  
-0.84 TEH TEC 16 COLD 60OUL 140 112 0.22 7
P3 TWD 12 DBC  
+1.61 TEH TEC 16 COLD 60OUL 141 67 0.31 71 P2 TWD 16 09C  
-1.07 TEH TEC 18 COLD 60OUL 141 83 0.24 136 P3 TWD 12 DBH  
+1.80 TEH TEC 16 COLD 600UL 141 89 0.37 114 P2 TWD 18 VHl  
-0.66 TEH TEC 16 COLD 600UL 141 103 0.23 31 P3 TWD 12 DBH  
+2.02 TEH TEC 16 COLD 600UL 0.26 31 P2 TWD 13 VH3  
-0.90 TEH TEC 16 COLD 600UL 0.26 83 P2 TWD 13 VH3  
+0.88 TEH TEC 16 COLD 600UL 141 109 0.54 88 P2 TWD 22 VH3  
+0.00 TEH TEC 15 COLD 60OUL 142 72 0.56 92 P3 TWD 27 DBC  
+2.05 TEH TEC 18 COLD 600UL 142 92 0.51 106 P2 TWD 22 VHl  
-0.88 TEH TEC 16 COLD 600UL 143 71 0.74 105 P2 TWD 29 VHl  
-0.86 TEH TEC 18 COLD 60OUL 0.53 81 P2 TWD 24 VHl  
+0.53 TEH TEC 18 COLD 600UL 0.45 126 P2 TWD 21 VHI  
+0.86 TEH TEC 18 COLD 600UL 0.32 108 P2 TWD 16 VH2  
-0.86 TEH TEC 18 COLD 600UL 0.57 108 P3 TWD 27 DOH  
+2.17 TEH TEC 18 COLD 60OUL 143 75 0.30 151 P3 TWD 18 DBC  
-1.68 TEH TEC 18 COLD 600UL 143 81 0.28 75 P2 TWD 14 VC1  
-0.78 TEH TEC 16 COLD 600UL 143 85 0.24 99 P3 TWD 13 DBC  
+1.32 TEH TEC 16 COLD 600UL 143 87 0.34 131 P2 TWD 15 10C  
+0.88 TEH TEC 15 COLD 600UL 0.59 61 P3 TWD 21 DBC  
+1.87 TEH TEC 15 COLD 600UL 0.26 53 P3 TWD 8 DBC  
-1.99 TEH TEC 15 COLD 600UL 143 91 0.19 52 P3 TWD 11 DBH  
+1.52 TEH TEC 16 COLD 600UL 143 105 0.22 166 P3 TWD 12 DBH  
+1.81 TEH TEC 16 COLD 600UL 143 107 0.22 18 P3 TWD 12 DBH  
-1.26 TEH TEC 16 COLD 60OUL 143 109 0.67 102 P3 TWD 27 DBC  
-1.93 TEH TEC 16 COLD 600UL 144 78 0.25 148 P2 TWD 13 VC1  
+0.82 TEH TEC 18 COLD 600UL 144 84 0.32 124 P3 TWD 13 DBC  
-1.86 TEH TEC 15 COLD 60OUL 0.19 17 P3 TWD 8 DBC  
+1.89 TEH TEC 15 COLD 60OUL 144 90 0.19 95 P2 TWD 10 VHI  
-0.98 TEH TEC 16 COLD 600UL 144 102 0.26 71 P3 TWD 14 DBH  
-1.64 TEH TEC 16 COLD 600UL 145 77 0.15 150 P3 TWD 10 DBH  
-1.80 TEH TEC 18 COLD 60OUL 145 89 0.27 147 P3 TWD 14 DBH  
+1.91 TEH TEC 16 COLD 600UL 0.44 84 P2 TWD 20 VC2  
+0.90 TEH TEC 16 COLD 600UL 145 99 0.40 97 P3 TWD 19 DOH  
+2.10 TEH TEC 16 COLD 60OUL 145 103 0.67 116 P3 TWD 27 DBH  
+1.69 TEH TEC 16 COLD 600UL 146 76 0.28 78 P3 TWD 17 DBH  
+2.17 TEH TEC 18 COLD 60OUL 146 78 0.50 96 P3 TWD 25 DBH  
+1.84 TEE TEC 18 COLD 600UL 0.42 144 P3 TWD 23 DBC  
+1.67 TEH TEC 18 COLD 60OUL 0.25 150 P3 TWD 15 DBC  
-1.65 TEH TEC 18 COLD 600UL 146 80 0.26 145 P3 TWD 16 DBC  
+1.62 TEH TEC 18 COLD 600UL 0.32 24 P3 TWD 19 DBH  
+1.88 TEH TEC 18 COLD 600UL 146 88 0.51 55 P3 TWD 23 DBC  
+1.64 TEH TEC 16 COLD 600UL Total Tubes
: 492 Total Records:
624


AREVA NP Inc                                         1/9/2008 2:18:17 PM Customer Name: San Onofre - Unit 2                   Component: S/G 89        Page 16 of 16 Post U2C15 Inspection Final Report MAI, MCI, MMI, MVIT, SAT, SCI, SVI, 0-100%, PCS QUERY: QueryMl(2].qry ROW LINE VOLTS DEG CHN   IND %TW LOCATION       EXT EXT   CAL # LEG   PROBE}}
AREVA NP Inc Customer Name: San Onofre -
Unit 2 Post U2C15 Inspection Final Report
: MAI, MCI,
: MMI, MVIT, SAT,
: SCI, SVI, 0-100%,
PCS QUERY: QueryMl(2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 1/9/2008 2:18:17 PM Component:
S/G 89 Page 16 of 16 EXT EXT CAL #
LEG PROBE}}

Latest revision as of 16:15, 14 January 2025

Transmittal of Special Report: Inspection of Steam Generator Tubes, Cycle 15
ML081780098
Person / Time
Site: San Onofre 
Issue date: 06/19/2008
From: Scherer A
Southern California Edison Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML081780098 (50)


Text

SOUTHERN CALIFORNIA A. Edward Scherer Director VNuclear Regulatory Affairs An EDISON INTERNATIONAL Company June 19, 2008 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-361 Special Report: Inspection of Steam Generator Tubes, Cycle 15 San Onofre Nuclear Generating Station, Unit 2

Dear Sir or Madam:

San Onofre Nuclear Generating Station Unit 2 entered Mode 4 on January 12, 2008 following the completion of an inspection of steam generator tubes during the Cycle 15 Refueling Outage. Technical Specification (TS) 5.7.2.c states "A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program."

Accordingly we have attached the required report. The report contains no new commitments.

If you require any additional information, please contact Clay Williams at (949) 368-6707.

Sincerely, Attachment cc:

E. E. Collins, NRC Regional Administrator, Region IV A (- /

N. Kalyanam, NRC Project Manager, San Onofre Units 2, and 3 G. G. Warnick, NRC Senior Resident Inspector, San Onofre Units 2 & 3 P.O. Box 128 San Clemente, CA 92674

Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 13 SPECIAL REPORT - INSPECTION OF STEAM GENERATOR TUBES Regulatory Reporting Requirements Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-10 requires a report of steam generator tube inspections to be submitted to the Nuclear Regulatory Commission within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.2.11, Steam Generator (SG) Program.

The report shall include:

1. The scope of inspections performed on each SG,

2. Active degradation mechanisms found,
3. Nondestructive examination techniques utilized for each degradation mechanism,
4. Location, orientation (if linear), and measured sizes (if available) of service induced indications,
5. Number of tubes plugged or repaired during the inspection outage for each active degradation mechanism,
6. Total number and percentage of tubes plugged or repaired to date,
7. The results of condition monitoring, including the results of tube pulls and in-situ testing,
8. The effective plugging percentage for all plugging and tube repairs in each SG, and
9. Repair method utilized and the number of tubes repaired by each repair method.

Inspection Scope Table 1 summarizes the scope of inspections performed on each SG. Also, when indications by the bobbin probe were non-quantifiable or distorted, the inspection scope included inspection with the Plus Point Probe. There were no significant inspection scope expansions in response to inspection results.

Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 13 TABLE I - Scope of Inspections Performed: Unit 2 Cycle 15 (U2C15) Refueling Outage Inspection Scope SG E-088 Tubes/Percent SG E-089 Tubes/Percent Full length of tube with the bobbin probe (excluding sleeved regions, tube section below sleeves and U-8093/100%

8224/100%

bends for Rows 1-3)

Hot leg expansion transition of unsleeved tubes at the top-of-tubesheet with the Plus Point Probe to an extent 7934/100%

8127/100%

of 4 inches above to 13 inches below the top-of-tubesheet Cold leg expansion transition at the top-of-tubesheet with the Plus Point Probe to an extent of 2 inches 8093/100%

8224/100%

above to 13 inches below the top-of-tubesheet U-bend regions of Rows 1, 2, and 3 with both mid-179/100%

171/100%

frequency and high-frequency Plus Point Probes U-bend regions of Rows 4 through 10 with the mid-90/22%

90/21%

frequency Plus Point Probe (Note 1)

Plus Point Probe examination of tube support intersections with dents greater than, or equal to, 2 2476/100%

1679/100%

volts Plus Point Probe examination of dings greater than, or 404/100%

309/100%

equal to, 4 volts Plus Point Probe examination of all tube support intersections with quantified wear indications by the 311/100%

387/100%

bobbin probe Full length of sleeves with the Plus Point Probe 159/100%

97/100%

Table 1 Note 1: No indications in a 100% inspection performed in 2004.

Inspection of Steam Generator Tubes Special Report Attachment Page 3 of 13 Results of the Inspection of Tubes Table 2 summarizes the degradation found and number of tubes plugged. Each tube is only counted once in this listing, although it may also have an eddy current indication of a type below the point in the listing where it appears. The Appendices provide detail.

No degradation was found in:

" the cold leg tubesheet region tubing bends dings in tubing freespan A robotic visual inspection of the untubed regions of the top of the tubesheet (i.e., tube bundle periphery and central blowdown lane) was performed on the secondary side of both Steam Generators.

One previously unretrievable analyzed object was again observed and re-verified unretrievable in the hot leg periphery of Steam Generator 88. Two previously unretrievable analyzed objects were again observed and re-verified unretrievable in the cold leg periphery and in the stay cavity region of Steam Generator 89. All three of these objects have an analysis for acceptability for tube integrity documented in the Corrective Action Process.

TABLE 2 - Degradation Found and Number of Tubes Plugged: U2C15 Refueling Outage Steam Generator E-088 E-089 Indication Orientation/Location Tubes with axially oriented ID (initiated on the inside-diameter of 1

2 the tubing wall) indications at tube support locations Tubes with axially oriented OD (initiated on the outside-diameter 28 47 of the tubing wall) indications at tube support locations Tubes with axially oriented OD indications not associated with a 2

2 tube support (freespan)

Tubes with circumferentially oriented ID indications near the 33 12 expansion transition at the top of the hot leg tubesheet Tubes with circumferentially oriented OD indications near the 15 22 expansion transition at the top of the hot leg tubesheet Tubes with axially oriented OD indications near the top of the hot 4

6 leg tubesheet Tubes with axially oriented ID indications in the hot leg tubesheet 34 10 region Tubes with circumferentially oriented ID indications in the hot leg 8

6 tubesheet region Tubes with indications of wear at tube support locations 7

17 Sleeved tubes with an eddy current signal indicative of the onset 1

1 of obstruction (Notes 1 and 2)

Total 133 125

Inspection of Steam Generator Tubes Special Report Attachment Page 4 of 13 Table 2 Note 1: These two sleeves were inspected full length with the rotating plus point probe.

They were not obstructed.

Table 2 Note 2: Overall, the rotating plus point probe inspection results for 100% of the sleeves indicated the effectiveness of previous significant preventive plugging. However, SCE Nuclear Fuel Management continues implementation of a conservative assumption (for accident analysis) that each remaining inservice sleeve may pose the potential for reactor coolant flow blockage, similar to that of a tube that is removed from service by plugging. The previous preventive plugging and the conservative assumption were described in the previous report (Letter from B. Katz (SCE) to Document Control Desk (NRC) dated February 7, 2006;

Subject:

Docket No. 50-361, Special Report: Inservice Inspection of Steam Generator Tubes, Cycle 14, San Onofre Nuclear Generating Station, Unit 2).

Examination Techniques Table 3 provides the list of Nondestructive Examination (NDE) techniques utilized for each degradation mechanism.

TABLE 3 - Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism Indication Orientation/Location Probe Type for Detection Characterization Circumferentially oriented and axially oriented ID indications near or below the expansion transition at the top of the hot leg and cold leg Plus Point Plus Point tubesheets Axially oriented OD indications and Circumferentially oriented OD Plus Point Plus Point indications near the top of the hot and cold leg tubesheets Axially oriented OD indications not associated with a tube support Bobbin Plus Point (freespan)

Bobbin Plus Point Axially oriented OD indications at tube support locations PlsPin Plus Point Plus Point (Note 1)

Plus Point Bobbin Plus Point Axially oriented ID indications at tube support locations PlsP in Plus Point Plus Point (Note 1)

Plus Point Indications of wear at tube support locations Bobbin Plus Point Axially oriented ID indications and Circumferentially oriented ID Plus Point Plus Point indications in Low-Row U-bends Circumferentially oriented ID indications at the flanks of tubing bends Plus Point Plus Point Axially oriented OD indications at dings in tubing freespan (dings <5 Bobbin Plus Point volts)

Axially oriented OD indications at dings in tubing freespan Plus Point Plus Point Axially and Circumferentially oriented ID and OD indications and volumetric indications at sleeve in parent tubing below lower and Plus Point Plus Point above upper joints, and joints Table 3 Note 1: Plus Point technique is used at dents greater than, or equal to, two volts

Inspection of Steam Generator Tubes Special Report Attachment Page 5 of 13 Condition Monitoring Condition Monitoring demonstrated that performance criteria in Technical Specifications sections 5.5.2.11.b.1 (structural integrity) and 5.5.2.11.b.2 (accident induced leakage) were met during operation prior to this inspection.

In situ pressure testing was not needed for any eddy current indications. All indications were below screening criteria of the Electric Power Research Institute (EPRI) In Situ Pressure Testing Guidelines.

Table 4 contains all crack-like indications. SONGS Unit 2 Technical Specifications contain alternate repair criteria for a portion of the tube in the tubesheet region. However, all tubes with crack-like indications were removed from service. Voltage is the only size-related measurement for numerous indications in Table 4. This is consistent with industry guidance for tube integrity assessment. Industry guidance provides ranges of voltage measurement values for which voltage is the only needed size-related measurement. Table 4 addresses location, orientation and measured sizes of service-induced indications (except wear of tubing at tube supports). Appendices 3 and 4 address location and measured sizes of service-induced indications of wear of tubing at tube supports.

No tubes were removed (pulled) for destructive testing during this outage.

TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 6

138 07H

-0.98 SAI OD 0.15 88 7

55 07C 0.97 SAI OD 0.32 88 7

137 TSH

-1.95 SCI ID 0.57 68 N/A 27 88 7

143 TSH

-4.84 SCI ID 0.33 88 8

156 TSH

-0.15 SCI ID 0.57 72 N/A 27 88 9

51 03H

-0.32 SAI OD 0.27 88 10 40 TSH

-0.08 SCI ID 0.23 88 11 147 TSH

-0.07 SCI ID 0.57 65 N/A 23 88 12 24 06H

-0.13 SAI OD 0.27 88 13 47 TSH

-0.02 SCI ID 0.33 88 13 55 05H 0.64 SAI OD 0.26 88 14 126 TSH

-0.15 SCI ID 0.40 88 14 130 TSH

-0.06 SCI ID 0.45 88 15 141 TSH

-2.8 SCI ID 0.27 88 16 140 TSH

-8.44 SCI ID 0.51 36 N/A 23 88 17 15 TSH

-6.32 SAI ID 0.55 56 N/A 0.64 88 17 15 TSH

-6.03 SAI ID 0.55 44 N/A 0.13 88 17 57 01H 0.75 SAI OD 0.31 88 17 57 06H 0.58 SAI OD 0.22 88 17 59 TSH

-1.09 SAI ID 0.42 88 18 34 TSH 0.05 SCI ID 0.32 88 19 141 TSH

-6.13 SAI ID 0.50 88 20 120 TSH

-0.19 SCI ID 0.42

Inspection of Steam Generator Tubes Special Report Attachment Page 6 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 21 31 TSH

-14.04 SCI ID 0.48 88 21 63 07C

-0.85 SAI OD 0.35 88 21 113 TSH

-2.37 SAI ID 0.52 54 N/A 0.15 88 21 127 04H 0.77 SAI OD 0.18 88 21 129 TSH

-0.09 SCI OD 0.31 88 22 52 03H

-0.7 SAI OD 0.31 88 23 109 TSH

-1.15 SAI ID 0.26 88 23 109 TSH

-0.79 SAI ID 0.51 49 N/A 0.12 88 23 109 TSH

-0.57 SAI ID 0.58 43 N/A 0.15 88 24 64 TSH

-0.81 SAI ID 0.95 36 N/A 0.15 88 24 160 06H

-0.06 SAI OD 0.20 88 25 117 TSH

-0.16 SCI ID 0.39 88 25 133 TSH

-0.14 SCI ID 0.70 53 N/A 27 88 25 133 TSH

-0.13 SCI ID 0.53 61 N/A 39 88 27 61 TSH

-4.41 SAI ID 0.87 39 N/A 0.15 88 27 61 TSH

-1.2 SAI ID 0.92 42 N/A 0.24 88 27 159 02H 0.03 SAI OD 0.23 88 27 159 02H 0.79 SAI OD 0.28 88 27 159 03H 0.87 SAI OD 0.49 88 28 120 TSH

-6.66 SAI ID 0.52 51 N/A 0.16 88 30 8

03H 0.85 SAI OD 0.24 88 30 38 TSH

-0.08 SCI ID 0.51 41 N/A 27 88 30 52 TSH 0.66 SAI OD 0.22 88 31 67 TSH

-0.06 SCI ID 0.61 73 N/A 27 88 31 69 TSH 0

SAI ID 0.57 32 N/A 0.12 88 31 107 TSH

-1.05 SAI ID 0.80 43 N/A 0.22 88 31 123 05H 0.66 SAI OD 0.28 88 31 165 05H

-0.34 SAI ID 0.76 66 N/A 0.18 88 31 165 05H 0.39 SAI ID 0.60 39 N/A 0.12 88 31 165 05H 0.54 SAI ID 0.39 88 32 112 TSH

-2.08 SAI ID 0.69 46 N/A 0.22 88 32 112 TSH

-1.63 SAI ID 0.81 46 N/A 0.18 88 32 122 TSH

-0.88 SAI ID 0.74 46 N/A 0.12 88 33 37 TSH

-0.1 SCI ID 0.42 88 34 108 TSH

-0.77 SAI ID 0.66 51 N/A 0.15 88 35 69 TSH

-1.07 SAI ID 0.47 88 36 70 TSH

-3.93 SAI ID 0.70 40 N/A 0.15 88 36 70 TSH

-3.11 SAI ID 0.51 34 N/A 0.12 88 36 70 TSH

-1.59 SAl ID 0.75 40 N/A 0.12 88 37 71 TSH

-2.58 SAI ID 0.66 43 N/A 0.12 88 38 28 01H 0.33 SAI OD 0.23

Inspection of Steam Generator Tubes Special Report Attachment Page 7 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 38 28 05H

-0.67 SAI OD 0.44 88 38 110 TSH

-1.44 SAI ID 0.79 38 N/A 0.15 88 38 110 TSH

-0.65 SAI ID 0.55 35 N/A 0.18 88 40 58 TSH

-3.72 SAI ID 0.41 88 40 162 06H 0.25 SAI OD 0.31 88 41 39 TSH

-1.42 SCI ID 0.71 39 N/A 31 88 41 69 TSH

-2.14 SAI ID 0.69 32 N/A 0.12 88 42 14 DBH

-0.81 SAI OD 0.16 88 42 14 DBH

-0.11 SAI OD 0.20 88 42 106 TSH

-1.18 SAI ID 0.46 88 43 73 TSH

-3.9 SAI ID 0.65 43 N/A 0.12 88 46 148 01H

-0.16 SAI OD 0.24 88 47 111 TSH

-3.12 SAI ID 0.35 88 47 111 TSH

-0.87 SAI ID 0.84 54 N/A 0.33 88 47 143 01H

-0.03 SAI OD 0.15 88 48 124 TSH

-0.1 SCI ID 0.28 88 48 134 TSH

-0.07 SCI ID 0.57 50 N/A 23 88 49 47 08C

-1.17 SAI GD 0.14 88 50 102 TSH

-0.42 SAI ID 0.40 88 50 106 TSH

-0.07 SAI ID 0.41 88 50 148 08H 0.81 SAI OD 0.38 88 51 55 TSH 0.03 SCI OD 0.29 88 51 57 TSH 0.06 SCI OD 0.36 88 51 117 TSH

-0.1 SCI ID 0.69 53 N/A 27 88 51 155 04H 0.75 SAI OD 0.21 88 52 72 TSH 0.23 SAI OD 0.17 88 52 112 TSH

-3.67 SAI ID 0.45 88 52 112 TSH

-3.37 SAI ID 0.67 43 N/A 0.31 88 52 112 TSH

-2.57 SAI ID 0.51 34 N/A 0.21 88 52 112 TSH

-1.87 SAI ID 0.79 43 N/A 0.55 88 53 57 TSH 0.15 MCI OD 0.28 88 53 113 TSH

-3.74 SAI ID 0.43 88 53 113 TSH

-5.31 SAI ID 0.68 41 N/A 0.18 88 53 113 TSH

-1.74 SAI ID 0.74 41 N/A 0.18 88 54 38 TSH

-0.02 SCI ID 0.49 88 54 60 TSH 0.15 SAI OD 0.17 88 54 72 TSH 0.06 SCI OD 0.20 88 56 126 TSH

-0.17 SCI ID 0.39 88 56 154 TSH

-7.34 SAI ID 0.53 38 N/A 0.12 88 57 73 TSH 0.09 SCI OD 0.12

Inspection of Steam Generator Tubes Special Report Attachment Page 8 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 57 105 TSH

-2.35 SAI ID 0.41 88 57 161 06H

-0.41 SAI OD 0.41 42 N/A 0.61 88 58 70 TSH

-2.27 SAI ID 0.65 54 N/A 0.12 88 59 83 TSH

-1.4 SAI ID 0.56 58 N/A 0.14 88 59 83 TSH

-0.87 SAI ID 0.30 47 N/A 0.12 88 60 86 VC3 0.84 SAI OD 0.23 88 60 106 TSH 0

SCI ID 0.31 88 62 80 TSH 0.03 SCI OD 0.22 88 62 114 TSH

-2.04 SAI ID 0.58 49 N/A 0.12 88 64 120 TSH

-0.03 SCI ID 0.47 88 65 87 TSH 0.06 SCI OD 0.14 88 65 111 TSH

-1.11 SAI ID 0.75 46 N/A 0.17 88 65 111 TSH

-0.15 SCI ID 0.41 88 67 111 TSH 0.16 SCI OD 0.16 88 68 112 TSH

-9.88 SCI ID 0.30 88 68 112 TSH

-6.12 MCI ID 0.55 72 N/A 74 88 69 119 TSH

-0.03 SCI ID 0.51 66 N/A 39 88 69 119 TSH

-0.02 SCI ID 0.37 56 N/A 19 88 70 86 TSH

-2.15 SAI ID 0.50 88 70 86 TSH

-1.84 SAI ID 0.46 88 70 104 TSH 0.17 SAI OD 0.29 88 72 100 TSH 0.05 SCI OD 0.33 88 75 95 TSH

-0.19 SCI ID 0.63 74 N/A 62 88 75 99 TSH 0.08 SCI OD 0.24 88 76 18 06H 0.62 SAI OD 0.22 88 77 85 TSH

-1.92 SAI ID 0.68 44 N/A 0.16 88 78 74 TSH

-0.06 SCI ID 0.32 88 78 96 TSH 0.11 SCI OD 0.20 88 78 98 TSH

-0.1 SCI ID 0.38 88 78 102 TSH 0

SCI ID 0.53 78 N/A 27 88 78 120 TSH

-6 SCI ID 0.39 88 79 81 TSH

-0.05 SCI ID 0.17 88 79 97 TSH 0.03 SCI OD 0.37 88 80 84 TSH

-0.08 SCI ID 0.24 88 81 93 TSH

-2.6 SAI ID 0.61 44 N/A 0.21 88 83 49 02H 2.02 SAI 0D 0.32 88 83 87 TSH

-0.12 SCI ID 0.45 88 88 60 01H 2.27 SAI OD 0.20 88 90 42 08H 0.75 SAI OD 0.26 88 90 42 VC2 0.12 SAI OD 0.24

Inspection of Steam Generator Tubes Special Report Attachment Page 9 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 88 90 78 TSH

-0.11 SCI ID 0.27 88 94 48 01H 0.21 SAI OD 0.24 88 95 71 TSH

-0.08 SCI ID 0.30 88 98 94 TSH 0

SCI OD 0.22 88 100 102 TSH

-0.07 SCI ID 0.19 88 100 118 TSH 0

SCI ID 0.39 88 107 97 TSH 0.03 SCI OD 0.28 88 111 67 02H 1.06 SAI OD 0.46 88 143 109 03H

-0.85 SAI OD 0.46 89 2

122 01H 0.74 SAI OD 0.30 89 3

127 07C 0.01 SAI OD 0.41 89 5

119 07H

-0.5 SAI OD 0.53 50 N/A 0.32 89 5

119 07C 0.61 SAI OD 0.33 89 5

119 07H

-0.3 SAI OD 0.33 89 6

58 TSH

-6.31 SCI ID 0.33 89 8

36 05H

-0.71 SAI OD 0.35 89 8

122 07H

-0.62 SAI OD 0.27 89 9

65 07H 0.73 SAI OD 0.32 89 9

117 05H 0.91 SAI OD 0.26 89 10 44 05H

-0.83 SAI OD 0.31 89 10 44 05H 0.54 SAI OD 0.23 89 11 19 04H

-0.19 SAI OD 0.23 89 11 19 06H 0.22 SAI OD 0.30 89 11 55 05H 0.94 SAI OD 0.37 89 11 65 01H 0.54 SAI OD 0.30 89 11 119 04H

-0.25 SAI OD 0.31 89 11 121 TSH

-10.71 SCI ID 0.50 89 11 131 TSH

-13.59 SCI ID 0.72 38 N/A 28 89 12 114 06H

-0.16 SAI OD 0.40 89 12 128 01H 0.58 SAI OD 0.22 89 12 128 04H 0.5 SAI OD 0.34 89 14 18 05H 0.88 SAI OD 0.17 89 14 58 04H 1.07 SAI OD 0.41 89 15 131 TSH

-0.1 SCI ID 0.43 89 15 141 TSH

-0.08 SCI ID 0.54 47 N/A 27 89 16 56 06H

-1.39 SAI OD 0.12 89 16 60 TSH

-0.09 SCI ID 0.39 89 17 49 TSH 0.08 SCI OD 0.13 89 18 26 06H

-0.15 SAI OD 0.20

Inspection of Steam Generator Tubes Special Report Attachment Page 10 of 13 TABLE 4 - Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 18 34 TSH

-5.71 SAI ID 0.29 89 18 34 TSH

-5.26 SAI ID 0.48 46 N/A 0.18 89 20 120 04H 0.69 SAI OD 0.49 45 N/A 0.7 89 20 120 04H

-0.26 SAI OD 0.42 89 23 137 TSH

-0.14 SCI ID 0.32 89 24 50 TSH 0.12 SCI OD 0.23 89 24 130 TSH 0.08 SCI OD 0.19 89 25 49 TSH 0.09 SCI OD 0.16 89 25 51 07C

-0.6 SAI OD 0.32 89 25 149 06H

-0.38 SAI OD 0.26 89 28 54 TSH 0.35 SAI OD 0.37 89 28 122 TSH 0.12 MCI OD 0.19 89 29 47 07H 0.61 SAI OD 0.30 89 29 59 TSH

-3.59 SAI ID 0.32 89 30 134 TSH

-6.96 SCI ID 0.47 89 32 48 TSH

-0.09 SCI ID 0.45 89 33 67 04H 0.5 SAI OD 0.26 89 33 67 TSH 0.47 SAI OD 0.17 89 33 67 TSH 0.62 SAI OD 0.21 89 34 112 04H

-0.34 SAI OD 0.28 89 35 49 TSH 0.27 SAI OD 0.14 89 35 111 04H

-0.29 SAI OD 0.21 89 35 111 TSH

-0.98 SAI ID 0.72 44 N/A 0.17 89 36 128 TSH 0.05 MCI OD 0.34 89 38 8

06H 0.7 SAI OD 0.23 89 39 45 TSH 0.04 MCI OD 0.18 89 39 131 TSH

-8.54 SAI ID 0.47 38 N/A 0.15 89 39 131 TSH

-7.5 SAI ID 0.60 40 N/A 0.12 89 39 133 TSH

-7.28 SAI ID 0.73 60 N/A 0.17 89 39 133 TSH 0.03 SCI OD 0.24 89 40 46 TSH 0.05 SCI OD 0.25 89 40 60 TSH 0.31 SAI OD 0.33 89 40 136 TSH

-8.81 SCI ID 0.51 53 N/A 27 89 41 131 TSH

-0.16 SCI ID 0.57 53 N/A 50 89 42 38 TSH

-0.12 SCI ID 0.91 71 N/A 31 89 45 63 TSH 0.19 SAI OD 0.26 89 45 63 TSH

-3.16 SAI ID 0.76 57 N/A 0.16 89 45 63 TSH

-2.39 SAI ID 0.53 60 N/A 0.16 89 46 48 TSH 0.14 SCI OD 0.13 89 46 126 03H

-0.29 SAI OD 0.41

Inspection of Steam Generator Tubes Special Report Attachment Page 11 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 46 134 06H 0.16 SAI OD 0.47 46 30.43 0.87 89 48 12 04H 0.61 SAI OD 0.35 89 48 52 TSH 0.12 SCI OD 0.15 89 48 64 TSH

-1.43 SAI ID 0.37 89 48 64 TSH

-2.18 SAI ID 0.43 40 N/A 0.13 89 48 130 TSH

-0.13 SCI ID 0.36 89 49 51 TSH 0.07 MCI OD 0.15 89 49 53 TSH 0.09 SCI OD 0.17 89 49 57 08H 1.54 SAI OD 0.31 89 50 106 TSH 0.15 SCI OD 0.27 89 52 120 TSH

-0.13 SCI ID 0.62 63 N/A 28 89 54 52 TSH

-5.76 SCI ID 0.44 89 54 102 01H 13.43 SAI OD 0.27 89 55 45 TSH

-0.16 SCI ID 0.36 89 57 77 TSH 0.07 MCI OD 0.25 89 57 97 TSH

-4.39 SAI ID 0.50 46 N/A 0.13 89 58 54 TSH

-6.25 SAI ID 0.34 89 59 53 TSH

-0.17 SCI ID 0.25 89 59 89 06C

-0.69 SAI OD 0.30 89 59 89 VH3 0.08 SAI OD 0.31 89 62 74 TSH 1.36 SAI OD 0.22 89 62 92 TSH 0.13 SCI OD 0.20 94 N/A 51 89 64 76 05H 0.67 SAI OD 0.28 89 64 80 TSH

-2.87 SAI ID 0.35 89 64 84 TSH 0.09 SCI OD 0.19 89 65 37 VSM

-0.93 SAI OD 0.21 89 70 68 TSH 0.06 SCI OD 0.24 89 70 92 TSH

-2.27 SAI ID 0.29 89 71 57 08H 0.52 SAI OD 0.15 89 71 67 TSH 0.14 SCI OD 0.46 89 75 53 TSH

-0.03 SCI OD 0.12 89 79 53 TSH

-0.02 SCI ID 0.57 53 N/A 27 89 79 89 TSH 1

SAI OD 0.17 89 79 99 TSH 0

SCI OD 0.33 89 83 73 03H

-0.11 SAI OD 0.29 89 85 81 TSH 0.19 SCI OD 0.31 89 87 31 05H 0.33 SAI ID 0.82 51 N/A 0.15 89 87 47 03H

-0.21 SAI OD 0.18 89 89 93 TSH

-13 SAI ID 0.48 46 N/A 0.12 89 91 85 03H 0.2 SAI OD 0.33 1

Inspection of Steam Generator Tubes Special Report Attachment Page 12 of 13 TABLE 4-Measured Sizes of Service-Induced Indications: U2C15 (continued)

SG Row Col Elev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 89 93 113 02H 0.84 SAI OD 0.35 89 98 62 TSH

-13.92 SAI ID 1.26 55 N/A 0.18 89 98 82 01H

-0.44 SAI OD 0.31 89 106 126 02H 0.24 MAI OD 0.44 89 108 52 06H 0.67 SAI ID 1.22 49 N/A 0.15 89 108 126 02H 0.66 SAI OD 0.33 89 110 122 02H 0.82 SAI OD 0.30 89 112 134 02H 0.5 SAI OD 0.54 51 N/A 0.74 89 118 62 01H 0.95 SAI OD 0.41 89 118 62 04H 0.95 SAI OD 0.25 89 118 124 02H 0.43 SAI OD 0.23 89 122 110 05H

-0.3 SAI OD 0.23 89 128 60 04H 0.75 SAI OD 0.42 89 130 82 01H

-0.27 SAI OD 0.67 55 N/A 0.61 Table 4 Notes:

SG 88 = SG E-088 SG 89 = SG E-089 PP = Plus Point Depth = Percent of Tube Wall Thickness PDA = Percent Degraded Area FLDA = Flaw-Length Degraded Area PP Length (units of measure are inches)

CA = Crack Angle (degrees)

Appendices 1 and 2 provide definitions for other terms

Inspection of Steam Generator Tubes Special Report Attachment Page 13 of 13 Repair Methods, Number of Tubes Repaired and Effective Plugging Percentage All tube plugging was performed using the design, materials, and installation methods of AREVA. A "roll" method was used for all tube plugs. Eighty-eight (88) tubes were "stabilized" in the vicinity of the top of the tubesheet using the design, materials, and installation methods of AREVA. Sleeving was not used for tube repair for the Cycle 15 outage. The design number of tubes in each SG is 9350 tubes and the sleeve-to-plug equivalency ratio is thirty-eight (38) sleeves per plug.

TABLE 5 - Number of Tubes Plugged or Repaired and Effective Plugging Percentage

  1. Tubes
  1. Tubes
  1. Sleeves Effective SG Plugged in Plugged To Remaining in Plugging 2C15 Date Service Percentage 88 133 1390 155 15.0%

89 125 1251 91 13.5%

Description of Appendices Appendix 1 -

Steam Generator Reference Information Appendix 2 -

Legend for Appendices 3 and 4 Appendix 3 -

Tube Inspection Summary, Steam Generator E-088 Appendix 4 -

Tube Inspection Summary, Steam Generator E-089

Inspection of Steam Generator Tubes Special Report Appendix 1 Page 1 of 4 Appendix 1 Steam Generator Reference Information

Inspection of Steam Generator Tubes Appendix 1 Special Report Page 2 of 4 Steam Generator CE Model 3410 Tube Support Drawing 1S" 16' 16' 16" 16' 16' 10H-10OC 30.75' 09H 09C 30.75' 08H 08C 30.7V 07H.

07C 38" 06H 06C 34" 05H 05C a5" 04H 04C 38" 03H 03C 36" 02H 02C 35.

O1H 0lC

________ J27.2S" TSH TSC 23' TEH TT-TEC

Inspection of Steam Generator Tubes Special Report Appendix 1 Page 3 of 4 STEAM GENERATOR TUBE SUPPORT INTERSECTIONS ABOVE THE 7 TH (FULL) EGGCRATE SUPPORT SUPPORT INTERSECTIONS ROW STRUCTURES 122-147 08H 09H 10H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 120-121*

08H 09H 10H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 115-119 08H 09H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 09C 08C 86-114 08H 09H DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 84-85*

08H 09H DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 83 08H DBH VH2 VH3 VSM VC3 VC2 DBC 08C 51-82 08H DBH VH3 VSM VC3 DBC 08C 49-50*

08H DBH VSM DBC 08C 19-48 DBH VSM DBC 1-18 DBH DBC

  • Indicates those rows adjacent to scallop bars

Inspection of Steam Generator Tubes Special Report Appendix 1 Page 4 of 4 SOUTHERN CALIFORNIA EDISON, SAN ONOFRE CE MODEL 3410 STEAM GENERATOR 10 z0 V) 40 50 rO 70 so so 10 110 120 130 140 150 160 170 140 130 120 100 s0 80 70 149 00 0

0o 00 00 600006Q0 00 0000 0 010 0-0 0 0 0

0 0 o'o 009 i'90 01

'001001 0

0 G 0 1

0-MMM, 59?mý-

Aq 200 130 0

a 06co 00 ý'ýa 430 P'6 &Q p

0 0 0ý0ý0ý0 080ý080ý0 0 00 00 10, 6 U616 16, 90 0

go 0

go jooso "v 0 9 0 0-0 a 6-0

' ' 2 0

00106100'0'00ý 200" 00 0 10-0220'0ý

?00 50040roo 0

9

-0 a,

69 o.

0 0-OX Mý.5'0iP5'.Q'0 ý26262528 62526262o -1

'-6'-26-206-'26 6 6 11600600 041, 000 00 00 00 0 0 0 6-,6 0 0 10 696 9

'01 010 0

0

.'4'. 0 0.-.0 00 OR 0

0 0

0 I solo 0,00

ý-'00:'52'0;'o ERR-0, 0 0 CR, 0("

2-'0200 000 v

o.'-',o- `-N'.

2n'ý "I

B 0 0

9 MQ

-zo Qý on.

890ý Ito 060606060 060606060 0 01 0

01 0ý0 o 100ý0 0

1 0 0 'go8o 0

0,0 0,0 ON 0

0 "Q Q-?Ugo 6006000 6 go 01 10 10

ý0 000 00 0

0 0

'00 0 C 00000 0000009,0,00 8`1 0 r"00 09, 3g" 0

l'o.0,0,0"0, 0.,. Qo,.,

0.

0 0 0

00 0 0 000 o 0-0 01OX0

4) 9 09 0 0

ozol(ý

ý559ý0 10ýO X0 0

0 N

0606 U Q-I

ý80-0 ý,,'§ 06ýO'

ý.-q g

o 0106 0 0 0 0 010 0

0 01

0 0.9 1

'D 06 60100 01 10 0 0

00ý0 8 ý 0

0 6

0 10 0

100 0 91, 0 620 ". " -

0 060 0

00 og 0

01 0 0

0 0

0 go lp

'*008' 0,08-0,6868 0 0 g'3 1

00 0

O'S loý 0 0 o 13" 0

C

'Q Q

9 0

Sý 601-1go 0 0

-0 g 011) so 1

j 0

0 0 0 9 0 0

00 0 0 010 00 000 10 0

NO.

10 0

o S 00 0..

00 0,

9.

0 0 0 ZýZ 0.19 -

-0 a

02 R?

9.0 01ý.01 r'=6ý I

'ý-o 0

ý0608qv.06 -

0 00 0'Q'00

'O'Z)401 16 60 0

00 00, 1ý go 000 9

goo 0

0 0 0 0 0 0 0 0 0

0,00,0'ý)0,0 ON".,

010 0

6,000 "G 43 0 4D 0ý 0'gý 0-0 "(20" g-

.0-0. 0 11 MR

.0 O-P.-O 6

6v vo'ý'

0 16 'n 0 0 0

0 6

0 10 0 0

0ý0 Q Qýqý'

0 0 0

00 0ý0 10 0

0 00 0

0 0

0 lclý 00 0 0 0

ý0

-0 L.11ý1 lolol lo V

6ao;0-6 0 00 gg-XXX 0 0 ý211 "9ý2 N.

l'ý ý 9,

9ý'-

000 0,6,0,20_ 6, '6'

'0ý 0,0 0,

0'.'M 10go 01-0 v "- o 0

0 C 0 0' ' -

01 OYY--6 01010 0 0 0 0 0 0 0

0 0000000092 0000000,0 Q'00' ý'Q 0

'o 0

16 00 0 0

(5 0- -0 0

0 0

0, g 0 0, o 010 "o

O.-;o 90,0, "00 OR

ýqo

_6yoý'

262 2 116&

0 1

0 0 0 0 Mo 0 160 11610, '6ý 0

Qu "1'

0.0 62 06-0 OZO Q6Q 10 goo 0,10 E0600600610ý "I 1

0610 060

ýQ o 0ý0 41 0 0 0

0 0 010 0

0

-No Yolyol

. 1'0'voý'o ogv".go

.6 0 0 0

0o Q 0 11 0 600,0 0

010 ýW'0'0

'0

?vROK.W. 0-R 60 0--

192%0 5:05ya 0yo-06-00yo 0

-6 oo'ý 0 R -5 6'w

ý'Oýo 0o MS.

R, 40 g

3Q.6,6 6

Q 0

op 0

010 01,0'00,0 0,00,o 9 0 0

o OV 0 606

6,'&Q,6oQ48

6' ' 6('

Q6M6vp: 6

&o" v v 9

0" 6ý 51011.0 01 00 0

'000 0

0 Oý.

0

)0000 000. 00QP'Q8Qo 0 5-0.1 0 2-P.

ý'Vi R.

N.

0 '10-o 000 0

ýQ 00

-g 06 0 0

-0 oi.. 00.,,

OPP

.01v "M.

&OP 0

"-Q 0.19.

0

-'o 0 0-0 0-"

0 Nog 0

ý5?090yn

-Oyd-

-MISL 6

30 60;06 000 0

06 0":

0 0

0 Q6o'5Q6Q

00.

0 0

9 Y'0

ýfqyq o

010 q0' oyopýo 0

010900168 000 0

0 0 9

00 C' 0

0 0 0 0 0go 9,00 10 5 00 00, 010 0 0

.'0 0 0 0

0Q'00'0Q'0' 20 a'292.a'ý 6 6-20 101ý1.01-01 0 0

K i goý. 00 0 "R. '121" 1ýc ZU g

0 006 00600600600ý00 0 eý 1W ovq'Xq o

60,6,Z

-0 so 40 30 20 01O0%00c005 1

0 x 0

1 1;

0

.oo7 0

oqqggý Z.p

.'0 qrsýý'

0-ozo-q- -oza-ý-

1^0*

Q~V5?6V6V6A5V~

6 ~ jp~co~o~0. &~~5~5Thft'&'

3Q5Y6 taL?&~

1 1

+

10 0000' 0 0 0 0 0 o.

0 o

0 Oo 00 0oo o 00oto-o-00 0000000 00 r,

ooe~~-bv T,

0*'¢0

°>

04 000000

(.

0 ol" 0 -

o%

0

s, gaa q g gg 10 20 so 40 s0 Go 70 80 90 100 110 10 ISO 140 1S ISO 170

Inspection of Steam Generator Tubes Special Report Appendix 2 Page 1 of 2 Appendix 2 Legend for Appendices 3 and 4

Inspection of Steam Generator Tubes Special Report Appendix 2 Page 2 of 2 List of Abbreviations and Format Used to Describe Indications from Rotating Probe Testing Abbreviations Explanation of the Abbreviations SCI Single Circumferential Indication MCI Multiple Circumferential Indications SAI Single Axial Indication MAI Multiple Axial Indications MMI Mixed Mode Indications SVI Single Volumetric Indication (i.e. no special axial or circumferential aspect)

MVI Multiple Volumetric Indications (i.e. no special axial or circumferential aspect)

PCS Partially Collapsed Sleeve TWD Through Wall Depth (an indication of tubing wear used for volumetric wear indicated with a percent value shown in the next column)

Format In Appendices 3 and 4, a single line of data is associated with each individual indication. Below is a descriptive example of the format.

The example above displays the format of a Report line. The VOLTS field contains the voltage of the largest, most representative response. The DEG field contains the corresponding phase angle. The CHN field contains the reporting channel (e.g., the appropriate axially or circumferentially sensitive 300kHz Plus Point channel). The IND field contains the appropriate 3-letter code (see list above). The

%TW field indicates the percent wall loss for wear indications. The LOCATION field contains the abbreviation for the referenced landmark and the distance to the indication. The EXT fields contain the landmarks of the beginning and end of the test extent. The CAL# field identifies the calibration number associated with the acquired data. The LEG field identifies the Hot or Cold Leg as the location of the probe origination. The PROBE field contains the abbreviated identifier of the probe type used for the inspection. For the second column, the terms line and column are used interchangeably for Combustion Engineering designed steam generators.

Inspection of Steam Generator Tubes Special Report Appendix 3 Page 1 of 14 Appendix 3 Tube Inspection Summary Steam Generator E-088

AREVA NP InC Customer Name: San Onofre -

Unit 2 01/09/08 14:19:36 Component: S/G 88 Page 2 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMi[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 1

133 0.40 0

P2 TWD 18 04C

-0.17 07C TEC 6

COLD 600UL 6

138 0.15 87 2

SAI 07H

-0.98 07H 07H 156 HOT 580PP 6

168 0.37 130 P2 TWD 18 04H

-0.31 TEC TEH 23 HOT 600UL 7

55 0.32 110 2 SAI 07C

+0.97 07C DBC 109 COLD 5809P 7

137 0.57 27 P1 SCI TSH

-1.95 TSH TSH 86 HOT 580PP 7

143 0.33 20 P1 SCI TSH

-4.84 TSH TSH 85 HOT 580PP 8

156 0.57 24 Pl SCI TSH

-0.15 TSH TSH 85 HOT 580PP 9

51 0.27 77 2

SAI 03H

-0.32 03H 03H 212 HOT 520ET 10 40 0.23 22 P1 SCI TSH

-0.08 TSH TSH 76 HOT 580PP 11 147 0.57 22 P1 SCI TSH

-0.07 TSH TSH 83 HOT 580PP 12 24 0.27 104 2 SAI 06H

-0.13 06H 06H 169 HOT 580PP 13 9

0.34 98 P2 TWD 14 05H

-0.14 TEC TEH 25 HOT 60OUL 13 47 0.33 21 P1 SCI TSH

-0.02 TSH TSH 80 HOT 580PP 13 55 0.26 69 2

SAI 05H

+0.64 05H 05H 183 HOT 580PP 13 159 0.14 45 P3 TWD 8 DBH

-2.25 TEC TEH 19 HOT 600UL 14 126 0.40 17 P1 SCI TSH

-0.15 TSH TSH 70 HOT 580PP 14 130 0.45 24 P1 SCI TSH

-0.06 TSH TSH 74 HOT 58OPP 15 119 0.43 133 P2 TWD 19 07C

-0.96 TEH TEC 49 COLD 600UL 15 141 0.27 23 P1 SCI TSH

-2.80 TSH TSH 79 HOT 58022 16 140 0.51 17 P1 SCI TSH

-8.44 TSH TSH 78 HOT 580PP 17 15 0.55 16 2

SAI TSH

-6.03 TSH TSH 72 HOT 580PP 0.55 13 2

SAI TSH

-6.32 TSH TSH 72 HOT 58OPP 17 57 0.31 123 2 SAI 01H

+0.75 01H 01H 189 HOT 580PP 0.22 97 2

SAI 06H

+0.58 06H 06H 189 HOT 580P2 17 59 0.42 15 2

SAI TSH

-1.09 TSH TSH 87 HOT 5802P 18 34 0.32 19 P1 SCI TSH

+0.05 TSH TSH 49 HOT 5802P 18 44 0.23 113 P3 TWD 10 DBH

-2.00 TEC TEH 13 HOT 60OUL 19 47 0.52 18 P3 TWD 19 DBC

+1.66 TEH TEC 37 COLD 600UL 19 135 0.36 147 P3 TWD 18 DBH

+2.00 TEC TEH 11 HOT 600UL 19 141 0.50 14 2

SAI TSH

-6.13 TSH TSH 79 HOT 580PP 20 68 0.37 68 P3 TWD 13 DBH

-1.71 TEH TEC 39 COLD 600UL 20 108 0.14 43 P3 TWD 6 DBH

-1.54 TEH TEC 50 COLD 600UL 20 120 0.42 16 P1 SCI TSH

-0.19 TSH TSH 64 HOT 580PP 21 31 0.48 23 P1 SCI TSH

-14.04 TSH TSH 52 HOT 580PP 21 61 0.47 17 P3 TWD 17 DBC

+1.98 TEH TEC 38 COLD 600UL 21 63 0.35 105 2 SAI 07C

-0.85 07C 07C 113 COLD 58OPP 21 67 0.32 79 P3 TWD 12 DBH

+2.00 TEH TEC 38 COLD 600UL 0.34 141 P2 TWD 13 VSM

+0.76 TEH TEC 38 COLD 600UL 21 113 0.52 17 2

SAI TSH

-2.37 TSH TSH 65 HOT 58OPP 21 127 0.18 107 2

SAI 04H

+0.77 04N 04H 150 HOT 580P2 21 129 0.31 52 P1 SCI TSH

-0.09 TSH TSH 65 HOT 5802?

AREVA NP Inc Customer Name:

San Onofre -

Unit 2 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, NVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMI[1].qry 01/09/08 14:19:36 Component:

S/G 88 Page 3 of 14 ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL 22 52 0.31 60 2

SAI 03H

-0.70 03H 03H 212 23 109 0.47 113 P2 TWD 20 VSM

+1.02 TEH TEC 50 0.51 15 2

SAI TSH

-0.79 TSH TSH 64 0.58 15 2

SAI TSH

-0.57 TSH TSH 64 0.26 14 2

SAI TSH

-1.15 TSH TSH 64 24 14 0.11 23 P2 TWD 7 VSM

+0.88 TEC TEH 22 24 64 0.95 13 2

SAI TSH

-0.81 TSH TSH 89 LEG PROBE HOT 520ET COLD 60OUL HOT 580PP HOT 580PP HOT 580PP HOT 60OUL HOT 580PP 24 156 0.38 101 P2 TWD 17 03H

+0.88 TEC TEH 20 HOT 60OUL 24 160 0.20 85 2

SAI 06H

-0.06 06H 06H 155 HOT 580?P 25 117 0.39 22 P1 SOI TSR

-0.16 TSH TSH 65 HOT 580PP 25 133 0.53 25 P1 SCI TSH

-0.13 TSH TSH 75 HOT 580PP 0.70 22 P1 SCI TSH

-0.14 TSH TSH 75 HOT 580PP 26 146 0.15 16 P3 TWD 5 DBH

+0.74 TEC TEH 16 HOT 60OUL 27 61 0.92 15 2

SAI TSH

-1.20 TSH TSH 89 HOT 580PP 0.87 14 2

SAI TSH

-4.41 TSH TSH 89 HOT 580PP 27 159 0.23 99 2

SAI 02H

+0.03 02H 02H 155 HOT 580PP 0.49 97 2

SAI 03H

+0.87 03H 03H 155 HOT 580PP 0.28 50 2

SAI 02H

+0.79 02H 02H 155 HOT 580PP 28 120 0.52 18 2

SAI TSH

-6.66 TSH TSR 64 HOT 580PP 30 8

0.24 96 2

SAI 03H

+0.85 03H 03H 169 HOT 580PP 30 38 0.51 18 P1 SCI TSH

-0.08 TSH TSH 102 HOT 580PP 30 52 0.22 73 2

SAI TSH

+0.66 TSH TSH 81 HOT 580PP 31 11 0.29 97 P3 TWD 11 DBH

+1.80 TEC TEH 25 HOT 600UL 31 65 0.54 10 P3 TWD 19 DBC

+2.00 TEH TEC 38 COLD 600UL 31 67 0.61 21 P1 SCI TSH

-0.06 TSH TSH 89 HOT 580PP 31 69 0.57 11 2

SAI TSH

+0.00 TSH TSH 93 HOT 5802P 31 107 0.80 15 2

SAI TSH

-1.05 TSH TSH 64 HOT 580PP 31 123 0.28 98 2

SAI 05H

+0.66 05H 05H 150 HOT 580PP 31 165 0.76 23 2

SAI 05H

-0.34 05H 05H 159 HOT 58OPP 0.60 14 2

SAI 05H

+0.39 05H 05H 159 HOT 5802P 0.39 16 2

SAI 05H

+0.54 05H 05H 159 HOT 580PP 32 4

0.31 131 P2 TWD 16 01C

-0.92 TEC TEH 26 HOT 60OUL 32 112 0.81 16 2

SAI TSH

-1.63 TSH TSH 65 HOT 580PP 0.69 15 2

SAI TSH

-2.08 TSH TSH 65 HOT 580PP 32 122 0.74 15 2

SAI TSH

-0.88 TSH TSH 71 HOT 58022 33 37 0.42 24 P1 SCI TSH

-0.10 TSH TSH 48 HOT 5802?

33 105 0.50 6

P3 TWD 21 DBC

+1.53 TEC TEH 36 HOT 600UL 0.31 144 P3 TWD 14 DBH

-1.69 TEC TEH 36 HOT 60OUL 0.20 82 P3 TWD 10 DBC

-1.59 TEC TEH 36 HOT 60OUL 34 108 0.66 19 2

SAI TSH

-0.77 TSH TSH 64 HOT 580PP 35 27 0.34 87 P2 TWD 14 VSR

+0.72 TEC TEH 17 HOT 600UL 0.37 77 22 TWD 15 VSM

-0.74 TEC TEH 17 HOT 600UL 35 69 0.47 15 2

SAT TSH 35 71 0.53 100 P3 TWD 19 DBC 36 70 0.75 14 2

SAI TSH 0.51 12 2

SAI TSH 0.70 14 2

SAI TSH

-1.07 TSH TSH 93 HOT 580PP

-1.90 TEH TEC 38 COLD 600UL

-1.59 TSH TSH 93 HOT 580PP

-3.11 TSH TSH 93 HOT 580PP

-3.93 TSH TSH 93 HOT 580PP 37 47 0.47 107 P2 TWD 20 VSM

+0.88 TEH TEC 317 COLD 600TUL

AREVA NP Inc Customer Name:

San Onofre -

Unit 2 01/09/08 14:19:36 Component:

S/G 88 Page 4 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCA 37 61 0.36 154 P2 TWD 14 VSM 37 71 0.66 15 2

SAI TSH 37 103 0.54 23 P3 TWD 22 DBH 38 28 0.23 90 2

SAI 0H 0.44 68 2

SAI 05H 38 110 0.79 13 2

SAI TSH 0.55 12 2

SAI TSH TION EXT EXT CAL # LEG PROBE

+0.93 TEH TEC 38 COLD 60OUL

-2.58 TSH TSH 93 HOT 580PP

-2.10 TEC TEH 35 HOT 60OUL

+0.33 01H 01H 169 HOT 580PP

-0.67 05H 05H 169 HOT 580PP

-1.44 TSH TSH 64 HOT 580PP

-0.65 TSH TSH 64 HOT 58OPP 39 43 0.46 10 P3 TWD 17 DBC

+1.33 TEC TEH 13 HOT 60OUL 39 71 0.35 128 P3 TWD 13 DBC

-1.55 TEH TEC 38 COLD 60OUL 40 58 0.41 15 2

SAI TSH

-3.72 TSH TSH 88 HOT 58OPP 40 162 0.31 120 2 SAI 06H

+0.25 06H 06H 158 HOT 580PP 41 7

0.40 137 P2 TWD 16 VSM

-0.77 TEC TEH 25 HOT 60OUL 41 39 0.71 12 P1 SCI TSH

-1.42 TSH TSH 48 HOT 580PP 41 69 0.69 11 2

SAI TSH

-2.14 TSH TSH 93 HOT 58OPP 41 73 0.41 110 P2 TWD 17 VSM

+0.93 TEH TEC 39 COLD 60OUL 0.23 34 P3 TWD 9 DBC

+1.43 TEH TEC 39 COLD 60OUL 41 101 0.17 85 P3 TWD 6 DBH

-1.79 TEC TEH 28 HOT 60OUL 0.22 53 P3 TWD 8 DBC

+1.91 TEC TEH 28 HOT 60OUL 42 14 0.16 140 2 SAI DBH

-0.81 DBH DBH 130 COLD 560P2 0.20 122 2 SAI DBH

-0.11 DBH DBH 130 COLD 560P2 42 74 0.36 86 P3 TWD 13 DBC

+1.32 TEH TEC 39 COLD 600UL 0.32 34 P3 TWD 12 DBC

-1.68 TEH TEC 39 COLD 600UL 42 106 0.71 126 P2 TWD 30 VSM

-0.98 TEC TEH 35 HOT 60OUL 0.46 14 2

SAI TSH

-1.18 TSH TSH 64 HOT 580PP 42 158 0.21 152 P3 TWD 11 DBH

+1.72 TEC TEH 19 HOT 60OUL 43 19 0.59 95 P2 TWD 25 02H

+0.87 TEC TEH 22 HOT 60OUL 43 51 0.93 105 P2 TWD 31 VSM

+0.88 TEH TEC 37 COLD 600UL 43 57 0.37 57 P3 TWD 13 DBH

+1.68 STH TEC 41 COLD 60OUL 0.22 46 P3 TWD 8 DBC

+1.72 STH TEC 41 COLD 60OUL 43 73 0.27 82 P3 TWD 11 DBC

-1.89 TEH TEC 38 COLD 600UL 0.65 15 2

SAI TSH

-3.90 TSH TSH 93 HOT 58OPP 43 101 0.34 58 P3 TWD 12 DBC

-1.68 TEC TEH 27 HOT 600UL 0.55 176 P3 TWD 19 DBC

+1.66 TEC TEH 27 HOT 600UL 43 125 0.57 106 P2 TWD 23 VSM

-0.84 TEH TEC 50 COLD 60OUL 44 58 0.22 21 P2 TWD 10 VSM

-1.08 TEH TEC 39 COLD 600UL 0.47 109 P2 TWD 19 VSM

+0.86 TEH TEC 39 COLD 600UL 44 108 0.27 81 P2 TWD 13 VSM

+0.87 TEC TEH 36 HOT 60OUL 0.34 132 P2 TWD 16 VSM

-0.77 TEC TEH 36 HOT 60OUL 44 124 0.38 107 P2 TWD 17 VSM

-0.95 TEH TEC 50 COLD 60OUL 45 73 0.38 126 P3 TWD 13 DBC

-1.61 STH TEC 41 COLD 60OUL 45 145 0.24 80 P2 TWD 12 VSM

+0.88 TEC TEH 15 HOT 60OUL 46 6

0.26 141 P3 TWD 13 DBC

+1.63 TEC TEH 26 HOT 60OUL 0.41 39 P2 TWD 19 VSM

-0.75 TEC TEH 26 HOT 60OUL 46 148 0.24 122 2 SAI 01H

-0.16 0H 01H 155 HOT 58OPP 47 109 0.38 90 P2 TWD 14 VSM

-0.02 STH TEC 41 COLD 60OUL 0.45 107 P2 TWD 16 VSM

+0.88 STH TEC 41 COLD 600UL 47 111 0.35 11 2

SAI TSH

-3.12 TSH TSH 64 HOT 58OPP

AREVA NP Inc Customer Name: San Onofre -

Unit 2 01/09/08 14:19:36 Component:

S/G 88 Page 5 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.84 19 2

SAI TSH

-0.87 TS1 TSH 64 HOT 58OPP 47 125 0.36 77 P2 TWD 16 VSM

+0.78 TEH TEC 50 COLD 600UL 47 143 0.15 78 2

SAI 01H

-0.03 01H 01H 155 HOT 580PP 48 76 0.58 90 P3 TWD 19 DBC

-1.75 TEC TEH 27 HOT 600UL 0.18 7

P3 TWD 6 DBH

+1.47 TEC TEN 27 HOT 60OUL 48 114 0.29 139 P3 TWD 14 DBH

-1.59 TEH TEC 49 COLD 60OUL 48 124 0.28 25 P1 SCI TSH

-0.10 TSH TSH 65 HOT 580PP 48 134 0.57 19 P1 SCI TSN

-0.07 TSH TSH 78 HOT 580PP 49 47 0.14 105 2 SAI 08C

-1.17 08C 08C 113 COLD 580PP 49 69 0.41 113 P2 TWD 16 08C

-1.22 TEH TEC 38 COLD 600UL 49 75 0.41 88 P3 TWD 17 DBH

-1.78 TEN TEC 36 COLD 600UL 50 8

0.28 131 P2 TWD 14 VSM

+0.77 TEC TEH 26 HOT 600UL 50 98 0.52 70 P2 TWD 22 VSM

-0.92 TEC TEH 28 HOT 60OUL 50 102 0.40 15 2

SAI 13W

-0.42 TSN TSN 127 NOT 580PP 50 106 0.41 13 2

SAI TSH

-0.07 TSH TSH 127 HOT 580PP 50 110 0.23 60 P2 TWD 12 08H

+0.87 TEC TEN 31 HOT 60OUL 50 148 0.38 101 2 SAI 08H

+0.81 08H 08H 155 HOT 58OPP 50 164 0.40 115 P2 TWD 18 VSM

+0.82 TEC TEH 20 HOT 600UL 51 55 0.29 114 P1 SCI TSH

+0.03 TSH TSH 87 HOT 58OPP 51 57 0.36 94 P1 SCI TSH

+0.06 TSH TSH 87 HOT 580PP 51 81 0.85 121 P3 TWD 26 DBC

-1.61 TEC TEH 27 HOT 600UL 0.46 169 P3 TWD 16 DBH

+1.43 TEC TEH 27 HOT 600UL 0.58 142 P3 TWD 19 DBH

-1.55 TEC TEH 27 HOT 60OUL 0.79 133 P3 TWD 25 DBC

+1.85 TEC TEH 27 HOT 600UL 51 117 0.69 21 P1 SCI TSH

-0.10 TSH TSH 64 HOT 58OPP 51 155 0.21 108 2 SAI 04H

+0.75 04H 04H 155 HOT 58OPP 51 163 0.39 41 P2 TWD 17 VH3

+0.90 TEC TEH 20 HOT 600UL 52 72 0.17 105 2 52 76 0.37 60 P3 52 112 0.79 15 2

0.51 12 2

0.67 15 2

0.45 13 2

SAI TSH TWD 13 DBC SAI TSH SAI TSH SAI TSH SAI TSH

+0.23 TSH TSH 94 HOT 580PP 53 57 0.28 98 P1 MCI TSH

+

53 113 0.68 14 2

SAI TSH 0.43 12 2

SAT TSH 0.74 14 2

SAi ISE 54 8

0.39 124 P2 TWD 18 01H

+

0.18 123 P2 TWD 10 01H 54 38 0.49 20 P1 SCI TSH 54 60 0.17 112 2 SAI TSH

+

54 72 0.20 79 P!

SCI TSH

+

54 76 0.41 48 P3 TWD 14 DBC 1.55 TEC TEN 27 HOT 60OUL 1.87 TSH TSH 65 HOT 580PP 2.57 TSH TSH 65 HOT 58OPP 3.37 TSH TSH 65 HOT 580PP 3.67 TSH TSH 65 HOT 580PP 0.15 1S3 TSH 88 HOT 580PP 5.31 TSH TSH 64 HOT 580PP 3.74 TSH TSH 64 HOT 58OPP 1.74 TSH TSH 64 HOT 58OPP 0.06 TEC TEN 26 HOT 600UL 1.06 TEC TEN 26 HOT 600UL 0.02 TSH TSH 49 HOT 580PP 0.15 TSH TSH 90 HOT 580PP 0.06 TSH TSH 93 HOT 580PP 1.65 TEC TEE 28 HOT 60OUL 1.84 TEC TEH 27 HOT 600UL 1.77 STH TEC 41 COLD 60OUL 54 92 0.10 44 P3 TWD 4 DBH 54 96 0.63 80 P3 TWD 20 DBH

AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -

Unit 2 Component:

S/G 88 Page 6 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 55 81 0.43 126 P3 TWD 15 DBH

-1.59 TEC TEH 27 HOT 600UL 55 91 0.61 128 P3 TWD 20 DBH

-1.67 TEC TEH 27 HOT 600UL 55 95 0.58 171 P3 TWD 19 DBC

+1.68 TEC TEH 27 HOT 60OUL 56 78 0.21 111 P3 TWD 8 DBH

-1.47 TEC TEH 28 HOT 600UL 56 80 0.92 141 P3 TWD 27 DBC

-2.00 TEC TEH 27 HOT 600UL 0.59 95 P3 TWD 20 DBH

-1.52 TEC TEH 27 HOT 600UL 0.27 11 P3 TWD 12 DBH

+1.75 TEC TEH 27 HOT 600UL 56 112 0.27 31 P3 TWD 12 DBH

-2.07 TEC TEH 31 HOT 60OUL 56 126 0.39 21 P!

SCI TSH

-0.17 TSH TSH 65 ROT 580PP 56 154 0.53 10 2

SAI TSH

-7.34 TSH TSH 85 HOT 580PP 57 73 0.12 103 21 SCI TSH

+0.09 TSH TSH 94 HOT 580PP 57 91 0.18 142 P3 TWD 8 DBC

-1.66 STH TEC 42 COLD 600UL 57 97 0.73 19 P3 TWD 23 DBH

+1.72 TEC TEH 28 HOT 60OUL 57 105 0.41 20 2

SAI TSH

-2.35 TSH TSH 59 HOT 580PP 57 109 0.37 78 P2 TWD 18 03H

-1.21 TEC TEH 31 HOT 600UL 57 161 0.41 114 2 SAI 06H

-0.41 06H 06H 155 HOT 580PP 57 167 0.52 147 P2 TWD 23 02C

+0.89 T.C TEH 23 HOT 600UL 58 70 0.65 19 2

SAI TSH

-2.27 TSH TSH 93 HOT 580PP 58 96 0.38 147 P3 TWD 15 DBH

-1.80 TEC TEH 27 HOT 600UL 58 100 0.40 57 P2 TWD 18 VSM

-0.80 TEC TEH 28 HOT 600UL 59 23 0.48 100 P2 TWD 19 VH3

-0.92 TEC TEH 21 HOT 600UL 59 25 0.41 155 P2 TWD 18 VH3

+0.84 TEC TEH 18 HOT 60OUL 0.35 138 P2 TWD 15 VH3

-0.82 TEC TEH 18 HOT 600UL 59 83 0.56 18 2

SAI TSH

-1.40 TSH TSH 50 HOT 58OPP 0.30 19 2

SAI TSH

-0.87 TSH TSH 50 HOT 580PP 59 95 0.28 22 P3 TWD 10 DBC

+1.58 TEC TEH 28 HOT 60OUL 59 161 0.41 80 P2 TWD 17 VH3

-0.90 TEC TEH 19 HOT 600UL 60 86 0.23 88 2

SAI VC3

+0.84 VC3 VC3 118 COLD 560P2 0.40 91 P2 TWD 16 VC3

+0.84 STH TEC 42 COLD 600UL 0.49 12 P3 TWD 17 DBH

+1.91 STH TEC 42 COLD 600UL 60 106 0.31 25 P1 SCI TSH

-0.00 TSH TSH 59 HOT 580PP 61 27 0.28 20 P2 TWD 12 VH3

-0.70 TEC TEH 18 HOT 60OUL 61 45 0.20 132 P3 TWD 9 DBC

+0.75 TEC TEH 13 HOT 600UL 61 85 0.27 160 P3 TWD 11 DBC

-1.58 TEC TEN 27 HOT 600UL 0.56 169 P3 TWD 20 DBC

+1.78 TEC TEH 27 HOT 600UL 61 87 0.32 154 23 TWD 11 DBC

-1.98 TEC TEH 27 HOT 60OUL 1.11 23 P3 TWD 31 DBH

+1.75 TEC TEH 27 HOT 600UL 61 125 0.27 143 P2 TWD 12 VC3

-0.10 TEC TEH 32 HOT 600UL 62 80 0.22 73 P1 SCI TSH

+0.03 TSH TSR 51 HOT 580PP 62 114 0.58 18 2

SAT TSH

-2.04 TSH TSH 60 HOT 58022 64 80 0.53 117 P3 TWD 18 DBH

+1.21 TEC TEH 27 HOT 60OUL 64 106 5.92 183 4

PCS SBH

+5.04 TO+13.33 STH SBH 101 HOT 500SP 64 120 0.47 26 P1 SCI TSH

-0.03 TSH TSH 59 HOT 580P2 65 81 0.22 108 P3 TWD 8 DBC

-1.22 TEC TEH 28 HOT 600UL 0.14 125 P3 TWD 6 DBC

+2.00 TEC TEH 28 HOT 600UL

AREVA NP Inc Customer Name: San Onofre -

Unit 2 01/09/08 14:19:36 Component:

S/G 88 Page 7 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAT, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 65 87 0.14 78 P1 SCI TSH

+0.06 65 91 0.21 26 P2 TWD 8 VH3

+0.70 65 111 0.41 21 P1 SCI TSH

-0.15 0.75 17 2

SAI TSH

-1.11 66 48 0.41 130 P2 TWD 18 VC3

-0.85 0.31 136 P2 TWD 15 VSM

+0.90 0.56 103 92 TWD 23 VSM

-0.90 67 81 0.62 91 P3 TWD 21 DBC

-1.35 TSH TSH 51 HOT 580PP TEC TEH 27 HOT 600UL TSH TSH 59 HOT 58OPP TSH TSH 59 HOT 580PP TEC TEN 34 ROT 600UL TEC TEH 34 HOT 600UL TEC TEH 34 HOT 600UL TEC TEH 27 HOT 600UL 67 87 0.30 28 P3 TWD 11 DBH

+1.60 TEC TEH 27 HOT 600UL 0.36 148 P3 TWD 13 DBE

-1.36 TEC TEH 27 HOT 600UL 67 111 0.16 103 P1 SCI TSH

+0.16 TSH TSH 60 HOT 58OPP 67 165 0.78 119 P2 TWD 30 VH3

-0.86 TEC TEH 23 HOT 600UL 68 112 0.55 24 P1 MCI TSH

-6.12 TSH TSH 127 HOT 580PP 0.30 18 PT SCI TSH

-9.88 TSH TSH 127 HOT 580PP 68 146 0.53 73 P2 TWD 21 VC3

-0.84 TEC TEH 15 HOT 600UL 68 164 0.57 102 P2 TWD 23 VH3

+0.63 TEC TEH 20 HOT 600UL 69 85 0.24 132 P3 TWD 8 DBC

-1.73 TEC TEH 27 HOT 60OUL 69 87 0.41 134 P3 TWD 15 DBH

+2.00 STH TEC 42 COLD 600UL 69 119 0.51 21 P1 SCI TSH

-0.03 TSH TSH 59 HOT 58OPP 0.37 20 P1 SCI TSH

-0.02 TSH TSH 59 HOT 58OPP 70 82 0.31 159 P3 TWD 11 DBC

+1.88 TEC TEH 28 HOT 600UL 70 86 0.34 51 P3 TWD 13 DBH

-1.42 TEC TEH 27 HOT 60OUL 0.50 15 2

SAI TSH

-2.15 TSH TSH 50 HOT 580PP 0.46 11 2

SAI TSH

-1.84 TSH TSH 50 HOT 580PP 70 104 0.29 109 2 SAI TSH

+0.17 TSH TSH 60 HOT 58OPP 71 13 0.55 123 P2 TWD 21 VH3

-0.79 TEC TEH 21 HOT 60OUL 72 70 0.31 87 P2 TWD 15 VC3

-0.93 TEC TEH 38 HOT 600UL 72 90 0.56 126 P2 TWD 22 VSM

+0.74 TEC TEH 27 HOT 600UL 0.27 29 P2 TWD 11 VSM

-0.98 TEC TEH 27 HOT 600UL 72 100 0.33 132 P1 SCI TSH

+0.05 TSH TSH 50 HOT 580PP 73 17 0.59 98 P2 TWD 22 VH3

-0.82 TEC TEH 21 HOT 600UL 73 75 0.33 135 P2 TWD 15 VC3

+0.60 TEC TEH 38 HOT 60OUL 73 133 0.41 110 P2 TWD 18 VH3

+0.81 TEC TEH 12 HOT 600UL 73 161 0.46 128 P2 TWD 19 VH3

+1.21 TEC TEH 20 HOT 600UL 74 148 0.22 83 P2 TWD 10 VH3

-0.92 TEC TEH 16 HOT 600UL 75 95 0.63 28 P1 SCI TSH

-0.19 TSH TSH 51 HOT 580PP 75 99 0.24 97 P1 SCI TSH

+0.08 TSH TSH 51 HOT 58OPP 75 141 0.33 129 P2 TWD 75 157 0.28 116 P2 TWD 76 18 0.22 96 2

SAI 76 84 0.34 121 P2 TWD 0.35 55 P2 TWD 76 86 0.24 23 P3 TWD 77 31 0.36 131 P2 TWD 0.24 105 22 TWD 14 VH3

-0.93 TEC TEH 16 HOT 600UL 13 VH3

-0.79 TEC TEH 20 HOT 600UL 06H

+0.62 06H 06H 169 HOT 580PP 14 VH3

+0.76 TEC TEH 27 HOT 600UL 15 VH3

-0.84 TEC TEH 27 HOT 600UL 9

DBC

+2.25 TEC TEH 28 HOT 600UL 14 VSM

+0.88 TEC TEH 17 HOT 600UL 11 VSM

+0.33 TEC TEH 17 HOT 60OUL

AREVA NP Inc Customer Name:

San Onofre -

Unit 2 01/09/08 14:19:36 Component: S/G 88 Page 8 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[ll.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 77 33 0.41 42 P2 TWD 18 VSM

+0.93 77 39 0.21 135 P3 TWD 11 DBC

+1.57 77 85 0.68 15 2

SAI TSH

-1.92 77 161 0.57 134 P2 TWD 22 VH3

-0.84 78 22 0.56 84 P2 TWD 24 VC3

-0.92 0.53 37 P3 TWD 23 DBC

-1.80 78 74 0.32 20 P1 SCI TSH

-0.06 78 96 0.20 114 P1 SCI TSH

+0.11 78 98 0.38 25 P1 SCI TSH

-0.10 EXT EXT CAL # LEG PROBE TEC TEH 18 HOT 600UL TEC TEH 14 HOT 600UL TSH TSH 50 HOT 580PP TEC TEH 20 HOT 60OUL TEC TEN 22 NOT 600UL TEC TEH 22 HOT 600UL TSN TSH 94 HOT 580PP TSN TSH 51 HOT 58OPP TSH TSH 51 HOT 58OPP 78 102 0.53 28 P1 SCI TSH

+0.00 TSH TSH 59 HOT 580PP 78 120 0.39 29 P1 SCI TSH

-6.00 TSH TSH 60 HOT 580PP 78 138 0.31 41 P3 TWD 14 DBC

+1.47 TEC TEH 12 HOT 60OUL 78 142 0.39 128 P2 TWD 16 VH3

+0.87 TEC TEH 16 HOT 600UL 78 144 0.66 47 P3 TWD 21 DBC

+1.65 TEC TEH 16 HOT 600UL 78 148 0.49 140 P2 TWD 20 08C

-0.92 TEC TEH 16 HOT 600UL 78 154 0.45 128 P2 TWD 19 VC3

+0.82 TEC TEH 20 HOT 60OUL 0.25 162 P2 TWD 12 VC3

-0.80 TEC TEH 20 HOT 600UL 79 15 0.41 19 P3 TWD 16 DBH

+1.45 TEC TEH 21 HOT 60OUL 79 19 0.23 40 P3 TWD 10 DBC

+1.84 TEC TEH 21 HOT 600UL 79 23 0.28 79 P3 TWD 12 DBC

+1.80 TEC TEH 21 HOT 600UL 79 81 0.17 22 P1 SCI TSH

-0.05 TSH TSH 50 HOT 580PP 79 97 0.37 120 P1 SCI TSH

+0.03 TSH TSH 50 HOT 580PP 79 143 0.18 111 P3 TWD 11 DBC

-1.50 TEC TEH 15 HOT 600UL 80 84 0.24 16 P1 SCI TSH

-0.08 TSH TSH 50 HOT 58OPP 80 112 0.32 81 23 0.37 81 93 0.61 81 151 0,35 0,12 82 54 0,74 0,13 82 160 0,25 83 49 0,32 83 87 0,45 115 54 P2 TWD 17 VSM

-0.84 TEC TEH 31 HOT 60OUL P3 TWD 15 DBC

+1.55 TEC TEH 7

HOT 600UL 15 2

SAI TSH

-2.60 TSH TSH 114 HOT 129 P2 TWD 16 VH3

+0.57 TEC TEH 11 HOT 29 P2 TWD 5 VH3

-0.21 TEC TEH 11 HOT 96 P2 TWD 25 VH3

-0.70 TEH TEC 16 COLI 170 P2 TWD 6 VH3

+0.91 TEH TEC 16 COLI 91 P3 TWD 13 DBH

+2.02 TEC TEN 11 HOT 104 2 SAI 02H

+2.02 02H 02H 173 HOT 580PP 600UL 600UL D

600UL D

600UL 600UL 580PP 25 PI SCI TSH 83 99 0,12 123 P3 TWD 5 DBH 84 48 0,64 92 P2 TWD 24 09C 85 43 0,56 131 P2 TWD 19 VH2 86 32 0,17 164 P3 TWD 7 DBC 86 54 0,24 119 P2 TWD 11 VH2 86 130 0.34 94 P2 TWD 17 VC2

-0.12

-1.75 TSH TSH 118 HOT 580PP TEN TEC 23 COLD 600UL TEH TEC 17 COLD 600UL TEC TEH 9

HOT 600UL

-1.50

-1.12

+1.75

-0.77

+--0-66 TEC TEH 7

TEH TEC 16 TEC TEH 6

HOT 600UL COLD HOT 600UL 600UL 87 37 0,36 131 P2 TWD 17 7H2

-0.94 0.38 133 P2 TWD 18 VH2

-1.06 87 63 0,42 116 P3 TWD 17 DBH

-0.25 TEC TEN 10 NOT 600Ut TEC TEN 10 HOT 600UL TEH TEC 19 COLD 600UL

AREVA NP Inc Customer Name: San Onofre -

Unit 2 01/09/08 14:19:36 Component:

S/G 88 Page 9 of 14 Post U2C15 Inspection Final Report MAT, MCI, MNT, NVI, SAT, SCI, EVI, 0-100%, PCS QUERY: QueryMlil].gry ROW LINE VOLTS DEG CHN IND

%TW LOCATION 88 60 0.20 91 2

SAI 01H 88 154 0.53 51 P2 TWD 22 VH2 89 35 0.43 94 P2 TWD 16 VH2 89 37 0.56 129 P2 TWD 19 VH2 89 51 0.32 73 P2 TWD 15 VH3 0.42 22 P3 TWD 17 DBH EXT EXT CAL # LEG PROBE

====::-=---=---- --

==

=

==

-=====-===*===:

+2.27 01H 01H 178 HOT 580PP

-0.83 TEC TEH 12 HOT 600UL

-0.93 TEC TEH 7

HOT 60OUL

-0.96 TEC TEH 9

HOT 600UL

+0.80

-1.85 TEH TEC 17 TEH TEC 17 COLD 60OUL COLD 60OUL 89 157 0.18 145 P3 TWD 10 DBH

+1.90 TEC TEH 11 HOT 600UL 90 42 0.24 104 2 SAI VC2

+0.12 VC2 09C 114 COLD 560P2 0.26 118 2 SAI 08H

+0.75 08H 08H 173 HOT 580PP 90 78 0.27 17 P1 SCI TSH

-0.11 TSH TSH 120 HOT 580PP 91 55 0.35 63 P2 TWD 16 VH2

+0.84 TEH TEC 17 COLD 60OUL 91 125 0.36 125 P2 TWD 16 VH2

-0.86 TEH TEC 29 COLD 60OUL 92 26 0.64 86 P2 TWD 25 VH2

-0.79 TEC TEH 8

HOT 600UL 92 36 0.56 87 P2 TWD 23 VH2

-0.89 TEC TEH 10 HOT 600UL 92 56 0.23 102 P2 TWD 12 09H

-0.64 TEH TEC 17 COLD 600UL 93 65 0.35 122 P2 TWD 16 VH2

-0.70 TEH TEC 19 COLD 600UL 93 153 0.37 68 P2 TWD 17 03C

+0.95 TEC TEH 12 HOT 60OUL 0.47 66 P2 TWD 20 05C

-0.89 TEC TEH 12 HOT 600UL 0.19 84 P2 TWD 10 VC3

-0.96 TEC TEH 12 HOT 600UL 94 24 0.41 131 P2 TWD 15 VH2

+1.12 TEC TEH 7

HOT 60OUL 94 40 0.38 119 P2 TWD 15 VH2

+1.12 TEC TEH 9

HOT 600UL 94 48 0.24 106 2 SAI 01H

+0.21 01H 01H 172 HOT 580PP 95 71 0.30 19 P1 SCI TSH

-0.08 TSH TSH 111 HOT 580PP 97 35 0.49 145 P2 TWD 18 VH2

-0.98 TEC TEH 7

HOT 600UL 98 44 0.25 27 P3 TWD 13 DBH

-2.20 TEC TEH 10 HOT 600UL 0.41 70 P2 TWD 18 VSM

+0.75 TEC TEH 10 HOT 600UL 98 94 0.22 89 P1 SCI TSH

+0.00 TSH TSH 114 HOT 580PP 99 49 0.27 18 P3 TWD 11 DBH

-2.00 TEH TEC 17 COLD 600UL 99 131 0.23 150 P2 TWD 12 VH3

+0.67 0.41 102 P2 TWD 19 VH3

-1.01 99 149 0.59 114 P2 TWD 24 VH2

+0.00 TEC TEN 6

NOT 600UL TEC TEH 6

HOT 600UL TEC TEH 11 HOT 600UL 100 102 0.19 21 P1 SCI TSH

-0.07 TSH TSH 54 HOT 58OPP 100 118 0.39 32 P1 SCI TSH

+0.00 TSH TSH 57 HOT 58OPP 101 29 0.45 137 P2 TWD 20 VH2

+0.77 TEC TEH 8

HOT 600UL 101 77 0.49 95 P3 TWD 18 DBH

+1.15 TEH TEC 21 COLD 600UL 101 147 0.56 147 P2 TWD 24 VSE

-0.74 TEC TEH 5

HOT 600UL 102 26 0.33 112 P2 TWD 16 06H

+0.87 TEC TEH 8

HOT 600UL 104 40 0.35 49 P3 TWD 17 DBC

+2.03 TEC TEH 10 HOT 600UL 105 99 106 30 106 106 76 78 0.40 132 P2 TWD 17 03H

+0.74 TEH TEC 23 COLD 60OUL 0.34 122 P2 TWD 14 06H

+0.81 TEC TEH 7

HOT 600UL 0.36 54 P2 TWD 15 02H

-0.20 TEH TEC 21 COLD 600UL 0.21 149 P2 TWO 10 VC2

-0.78 TEN TEC 20 COLD 600UL 0.26 149 P2 TWD 11 VC2

+0.89 TEH TEC 20 COLD 60OUL

AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 10 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[13.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 107 29 0.55 9

P3 TWD 23 DBC

+1.29 TEC TEH 8

HOT 600UL 107 33 0.22 107 P2 TWD 12 09H

-0.37 TEC TEH 8

HOT 60OUL 107 75 0.34 66 P2 TWD 14 09C

-0.29 TEH TEC 7

COLD 60OUL 107 95 0.31 126 P2 TWD 13 VH2

+0.82 TEH TEC 23 COLD 60OUL 107 97 0.28 135 P1 SCI TSH

+0.03 TSH TSH 114 HOT 580PP 0.29 115 P2 TWD 12 VH3

-0.88 TEH TEC 22 COLD 600UL 107 125 0.46 111 P2 TWD 19 VN2

-0.69 TEN TEC 29 COLD 60OUL 0.22 101 23 TWD 9 DBH

-1.42 TEH TEC 29 COLD 600UL 108 36 0.32 79 P3 TWD 15 DBC

-1.80 TEC TEH 10 HOT 60OUL 108 142 0.16 151 P3 TWD 8 DBE

+1.66 TEC TEH 6

HOT 600UL 109 77 0.26 132 P2 TWD 11 VH2

+0.82 TEH TEC 21 COLD 600UL 1i0 52 0.19 97 P3 TWD 9 DBH

-1.33 TEH TEC 16 COLD 600UL 110 96 0.23 91 P3 TWD 9 DBH

+2.24 TEH TEC 23 COLD 600UL 110 138 0.37 116 P2 TWD 18 VC3

-0.90 TEC TEH 6

HOT 600UL I11 33 0.15 11 P3 TWD 8 DBH

+1.75 TEC TEN 8

HOT 600UL 111 37 0.29 20 P3 TWD 14 DBH

+1.85 TEC TEH 10 HOT 60OUL 111 67 0.46 115 2 SAI 02H

+1.06 02H 02H 178 HOT 580PP 11 81 0.23 142 P3 TWD 10 DBH

+2.24 TEN TEC 21 COLD 600UL il1 101 0.21 56 P3 TWD 8 DBH

-0.75 TEH TEC 23 COLD 600UL 112 92 0.35 32 P2 TWD 15 VH2

-0.70 TEH TEC 23 COLD 600UL 112 116 0.15 47 P2 TWD 7 VH3

-0.85 TEH TEC 30 COLD 600UL 112 144 0.86 158 P3 TWD 30 DBH

+2.13 TEC TEH 5

HOT 600UL 113 37 0.36 135 P2 TWD 14 VH2

-0.93 TEC TEN 9

HOT 600UL 0.17 138 P3 TWD 8 DBH

+1.84 TEC TEH 9

HOT 600UL 113 39 0.42 109 P3 TWD 17 DBH

+1.98 TEC TEH 9

HOT 600UL 113 41 0.47 94 P2 TWD 17 VH2

-0.68 TEC TEH 9

HOT 600UL 113 47 0.25 35 P3 TWD 11 DBH

-1.34 TEH TEC 17 COLD 600UL 113 87 0.16 144 P3 TWD 6 DBH

-1.52 TEH TEC 23 COLD 60OUL 114 38 0.30 138 P2 TWD 12 06C

-0.69 TEC TEH 9

HOT 600UL 114 86 0.12 164 P3 TWD 4 DBH

-1.37 TEH TEC 23 COLD 600UL 114 96 0.32 102 P2 TWD 13 VH3

-0.82 TEH TEC 24 COLD 600UL 114 110 0.31 44 P3 TWD 14 DBH

-1.57 TEH TEC 30 COLD 600UL 115 83 0.36 138 P3 TWD 14 DBH

-1.54 TEH TEC 21 COLD 600UL 115 93 0.25 121 P3 TWD 13 DBE

-1.23 TEN TEC 24 COLD 600UL 115 101 0.18 46 23 TWD 7 DBH

+2.15 TEH TEC 23 COLD 600UL 115 137 0.64 36 P2 TWD 26 VHN

-0.98 TEC TEH 5

HOT 600UL 116 64 0.20 104 P3 TWD 9 DBH

-1.13 TEH TEC 19 COLD 600UL 116 92 0.23 119 P2 TWD 10 04H

+0.86 TEH TEC 23 COLD 600UL 116 102 0.41 125 P3 TWD 15 DBH

+0.93 TEh TEC 33 COLD 600UL 117 55 0.66 124 P2 TWD 25 VHI

-0.72 TEH TEC 17 COLD 600UL 117 67 0.42 124 P2 TWD 18 VHI

-0.78 TEH TEC 19 COLD 60OUL 117 95 0.20 55 P3 TWD 10 DBH

+1.98 TEH TEC 24 COLD 60OUL

AREVA NP Inc 01/09/08 14:19:36 Customer Name: San Onofre -

Unit 2 Component:

S/G 88 Page 11 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryM!(1].qry ROW LINE VOLTS DEG CHN IND

%TW LOCATION EXT EXT CAL # LEG PROBE

- - - -----= --------------= ------

=

--= --= --=

=

-=

=-

== = = =-

=-

== = = = =-

-==

=-

=:

118 38 0.14 133 P3 TWD 6 DBC

+1.94 TEC TEH 9

NOT 600UL 118 68 0.23 77 P3 TWD 11 DBE

-1.69 TEH TEC 18 COLD 600UL 118 72 0.18 36 P3 TWD 7 DBH

+1.88 TEH TEC 20 COLD 60OUL 0.24 143 P3 TWD 11 DBH

-1.98 TEH TEC 20 COLD EODUL 118 88 0.42 149 P3 TWD 17 DBH

-1.64 TEH TEC 22 COLD 60OUL 118 90 0.20 37 P3 TWD 9 DBE

-1.98 TEH TEC 22 COLD 600UL 119 37 0.11 53 P3 TWD 6 DBC

-2.11 TEC TEH 10 HOT 60OUL 0.31 11 P3 TWD 15 DBC

+2.15 TEC TEH 10 HOT 60OUL 0.18 22 P2 TWD 10 10C

-1.33 TEC TEH 10 HOT 600UL 119 55 0.35 89 P3 TWD 15 DBH

+2.15 TEH TEC 16 COLD 600UL 119 79 0.49 119 P3 TWD 19 DBH

+2.02 TEH TEC 20 COLD 60OUL 119 95 0.49 103 P3 TWD 21 DBH

-1.83 TEH TEC 24 COLD 600UL 119 97 0.39 137 P3 TWD 15 DBH

-1.57 TEH TEC 25 COLD 60OUL 119 99 0.33 126 P3 TWD 16 DBH

-1.93 TEH TEC 24 COLD 60OUL 119 101 0.37 115 P3 TWD 14 DBH

-1.74 TEH TEC 23 COLD 60OUL 119 109 0.47 15 P3 TWD 20 DBH

+1.91 TEH TEC 30 COLD 60OUL 120 38 0.19 148 P3 TWD 10 DBC

-1.82 TEC TEH 10 HOT 600UL 0.22 117 P3 TWD 11 DBC

+2.25 TEC TEH 10 HOT 600UL 120 48 0.30 84 P2 TWD 14 VH2

-0.76 TEH TEC 17 COLD 60OUL 120 66 0.46 107 P3 TWD 19 DBH

-1.32 TEH TEC 18 COLD 60OUL 120 74 0.23 101 P2 TWD 10 10H

-1.19 TEH TEC 20 COLD 60OUL 120 78 0.30 135 P2 TWD 13 VHN

-0.73 TEH TEC 21 COLD 60OUL 120 80 0.27 63 P3 TWD 12 DBH

-1.96 TEH TEC 20 COLD 600UL 120 86 0.24 115 P3 TWD 11 DBH

-1.60 TEH TEC 22 COLD 600UL 0.35 103 P2 TWD 15 10H

+1.25 TEH TEC 22 COLD 60OUL 120 92 0.33 91 P3 TWD 13 DBH

-2.11 TEH TEC 23 COLD 600UL 120 94 0.11 135 P3 TWD 6 DBH

-1.95 TEH TEC 24 COLD 600UL 120 106 0.88 154 P3 TWD 24 DBH

+1.84 TEH TEC 32 COLD 60OUL 120 138 0.50 128 P3 TWD 21 DBH

-1.87 TEC TEH 5

HOT 600UL 121 39 0.41 72 P2 TWD 19 03C

-0.91 TEC TEH 10 HOT 600UL 121 67 0.25 94 P3 TWD 11 DBH

-1.75 TEH TEC 19 COLD 60OUL 121 69 0.30 17 P2 TWD 14 04H

+0.83 TEH TEC 19 COLD 600UL 121 71 0.22 137 P3 TWD 10 DBH

-1.60 TEH TEC 19 COLD 600UL 121 125 0.44 137 P2 TWD 17 10H

+0.73 TEH TEC 28 COLD 600UL 121 137 0.26 153 P3 TWD 13 DBH

-1.85 TEC TEH 5

NOT 60OUL 122 76 0.55 110 P2 TWD 21 VHl

+0.00 TEH TEC 21 COLD 600UL 122 94 0.32 145 P3 TWD 15 DBH

+1.92 TEH TEC 24 COLD 60OUL 122 96 0.46 141 P3 TWD 20 DBH

+1.93 TEH TEC 24 COLD 600UL 122 98 0.61 108 P2 TWD 22 l0H

+1.21 TEH TEC 24 COLD 600UL 0.24 140 P3 TWD 12 DBH

+1.95 TEH TEC 24 COLD 600UL 122 112 0.25 109 P2 TWD 11 10H

-1.16 TEN TEC 30 COLD 600UL 122 114 0.42 77 P2 TWD 17 10H

+0.95 TEH TEC 31 COLD 600UL 0.35 149 P3 TWD 13 DBH

+1.52 TEN TIC 31 COLD 600UL

AREVA NP Inc 01/09/08 14:19:37 Customer Name: San Onofre -

Unit 2 Component:

S/G 88 Page 12 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, EVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryM![l.qry ROW LINE VOLTS DEG CHN IND

%TW LOCATION EXT EXT CAL # LEG PROBE 122 124 0.46 128 P3 TWD 20 DBE

+1.84 TEH TEC 28 COLD 600UL 123 65 0.31 117 P3 TWD 14 DBH

-0.35 TEH TEC 18 COLD 600UL 124 64 0.54 107 P2 TWD 22 10H

-1.07 TEH TEC 19 COLD 60OUL 124 88 0.34 56 P3 TWD 13 DBH

+1.98 TEE TEC 23 COLD 600UL 125 91 0.33 140 P3 TWD 13 DBH

+1.87 TEN TEC 23 COLD 600UL 126 86 0.48 134 P3 TWD 18 DBH

+1.98 TEH TEC 23 COLD 60OUL 126 90 0.40 110 P3 TWD 16 DBH

+1.91 TEH TEC 22 COLD 60OUL 126 112 0.55 40 P3 TWD 22 DBH

+1.89 TEH TEC 30 COLD 600UL 127 53 0.60 100 P2 TWD 21 VHI

-0.85 TEH TEC 16 COLD 600UL 127 83 0.33 113 P3 TWD 14 DBH

-1.95 TEH TEC 20 COLD 60OUL 128 60 0.62 115 P2 TWD 22 10H

-1.19 TEH TEC 16 COLD 60OUL 0.40 64 P2 TWD 16 10H

+0.02 TEH TEC 16 COLD 60OUL 128 68 0.30 24 P3 TWD 12 DBH

+1.62 TEH TEC 19 COLD 600UL 129 47 0.77 129 P2 TWD 27 VH3

-0.90 TEH TEC 17 COLD 60OUL 129 63 0.37 100 P2 TWD 17 10H

-0.10 TEH TEC 19 COLD 600UL 129 67 0.49 79 P3 TWD 19 DBH

-2.00 TEH TEC 19 COLD 60OUL 130 74 0.41 66 P2 TWD 17 10H

+0.08 TEH TEC 21 COLD 60OUL 0.69 159 P2 TWD 24 10H

-1.07 TEH TEC 21 COLD 600UL 130 78 0.41 124 P2 TWD 16 VHl

+0.91 TEH TEC 20 COLD 600UL 130 128 0.46 67 P2 TWD 19 VH2

-0.48 TEH TEC 29 COLD 60OUL 131 83 0.20 111 P3 TWD 9

DBH

-1.74 TEH TEC 26 COLD 600UL 131 89 0.65 119 P2 TWD 25 10H

+0.94 TEH TEC 26 COLD 600UL 131 127 0.48 117 P2 TWD 17 03C

+0.82 TEH TEC 51 COLD 600UL 132 94 0.56 69 P2 TWD 22 10H

+0.95 TEH TEC 26 COLD 600UL 133 75 0.45 117 P3 TWD 17 DBH

+2.03 TEH TEC 25 COLD 600UL 133 83 0.51 158 P2 TWD 20 10H

-1.04 TEH TEC 27 COLD 600UL 133 115 0.42 114 P2 TWD 16 10H

+0.88 TEH TEC 28 COLD 600UL 134 66 0.18 113 P3 TWD 8 DBH

+0.98 TEH TEC 25 COLD 600UL 134 68 0.30 130 P2 TWD 13 10H

-0.71 TEH TEC 25 COLD 600UL 134 82 0.16 33 P3 TWD 7 DBH

+2.04 TEH TEC 27 COLD 600UL 134 84 0.78 136 P2 TWD 27 10H

-1.14 TEH TEC 27 COLD 600UL 134 86 1.14 141 P2 TWD 33 10H

-1.02 TEH TEC 27 COLD 600UL 134 100 0.41 154 P2 TWD 17 10H

+0.91 TEH TEC 27 COLD 600UL 135 67 0.08 25 P3 TWD 3 DBH

+2.25 TEH TEC 25 COLD 600UL 135 87 0.78 153 P2 TWD 28 10H

-1.04 TEH TEC 26 COLD 60OUL 135 91 0.41 109 P2 TWD 17 03H

-0.28 TEH TEC 27 COLD 60OUL 135 93 0.36 42 P2 TWD 15 10H

+0.98 TEH TEC 27 COLD 600UL 135 97 0.17 30 P2 TWD 8 10H

+0.92 TEH TEC 26 COLD 600UL 136 74 0.35 123 P2 TWD 15 10H

-1.02 TEH TEC 24 COLD 600UL 136 86 0.31 145 P2 TWD 14 10H

-0.96 TEH TEC 26 COLD 600UL 137 91 0.56 157 P2 TWD 22 10H

-1.08 TEH TEC 26 COLD 60OUL

AREVA NP Inc 01/09/08 14:19:37 Customer Name: San Onofre -

Unit 2 Component:

S/G 88 Page 13 of 14 Post U2C15 Inspection Final Report

MAT, MCI,
MMI, MVI,
SAi, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[l].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 137 119 0.41 80 P2 TWD 17 01C

-0.95 TEH TEC 29 COLD 60OUL 138 84 0.40 117 P2 TWD 17 VHi

+0.86 TEH TEC 27 COLD 600UL 139 61 0.46 120 P2 TWD 18 VHl

-0.93 TEH TEC 25 COLD 60OUL 139 105 0.56 75 P2 TWD 22 10H

+0.83 TEH TEC 29 COLD 60OUL 140 76 0.18 72 P3 TWD 8 DBH

-2.04 TEH TEC 26 COLD 600UL 140 88 0.25 140 P3 TWD 11 DBH

+1.86 TEH TEC 26 COLD 600UL 141 63 0.11 166 P3 TWD 5 DBC

-2.04 TEH TEC 25 COLD 600UL 0.40 17 P3 TWD 15 DBC

+1.63 TEH TEC 25 COLD 600UL 141 65 0.34 108 P2 TWD 15 08C

+0.77 TEH TEC 25 COLD 60OUL 141 67 0.69 108 P2 TWD 24 VC1

+0.86 TEH TEC 24 COLD 60OUL 141 77 0.25 121 P2 TWD 12 VC1

+0.90 TEH TEC 26 COLD 60OUL 0.30 71 P3 TWD 13 DBC

+1.61 TEH TEC 26 COLD 600UL 141 87 0.18 107 P2 TWD 9 VCt

+0.91 TEH TEC 27 COLD 600UL 142 66 0.44 172 P3 TWD 17 DBC

+1.49 TEH TEC 25 COLD 600UL 142 68 0.25 125 P2 TWD 11 10H

-0.24 TEH TEC 25 COLD 600UL 142 84 0.47 119 P3 TWD 17 DBC

+1.69 TEH TEC 27 COLD 600UL 142 86 0.20 116 P3 TWD 9 DBH

+1.90 TEH TEC 26 COLD 600UL 142 90 0.27 111 P3 TWD 11 DBH

+2.07 TEH TEC 27 COLD 600UL 142 98 0.29 15 P3 TWD 13 DBC

+1.44 TEH TEC 26 COLD 600UL 142 104 0.34 20 P3 TWD 13 DBH

+1.60 TEH TEC 29 COLD 60OUL 142 110 0.54 42 P3 TWD 19 DBH

+1.80 TEH TEC 29 COLD 600UL 143 83 0.49 38 P3 TWD 18 DBC

+1.57 TEH TEC 27 COLD 600UL 143 89 0.27 64 P3 TWD 11 DBH

-1.63 TEH TEC 26 COLD 600UL 143 109 0.23 126 P3 TWD 10 DBH

-1.57 TEH TEC 29 COLD 600UL 0.27 122 P2 TWD 13 VC2

+0.78 TEH TEC 29 COLD 600UL 0.46 73 2

SAT 03H

-0.85 03H 03H 152 HOT 580PP 144 76 0.19 48 P2 TWD 9 04H

-0.08 TEH TEC 26 COLD 600UL 0.38 130 P2 TWD 17 VC2

+0.92 TEN TEC 26 COLD 600UL 144 78 0.29 143 P2 TWD 13 VC2

+0.90 TEH TEC 26 COLD 600UL 0.43 122 P3 TWD 17 DBC

-1.53 TEH TEC 26 COLD 600UL 144 80 0.45 131 P3 TWD 18 DBH

+1.93 TEH TEC 26 COLD 600UL 144 86 0.31 139 P3 TWD 12 DBH

+1.97 TEH TEC 27 COLD 600UL 144 96 0.42 129 P3 TWD 17 DBH

+2.00 TEH TEC 26 COLD 60OUL 0.54 129 P3 TWD 20 DBC

+1.26 TEH TEC 26 COLD 600UL 145 79 0.59 100 P3 TWD 20 DBC

+1.69 TEH TEC 27 COLD 600UL 145 87 0.20 146 P3 TWD 8 DBC

-1.87 TEH TEC 26 COLD 600UL 0.19 34 P3 TWD 8 DBC

+1.81 TEH TEC 26 COLD 600UL 0.41 109 P2 TWD 18 VC1

+1.08 TEH TEC 26 COLD 60OUL 145 89 0.26 91 P3 TWD 10 DBH

-1.75 TEH TEC 27 COLD 600UL 0.34 48 P2 TWD 15 VC1

+0.85 TEh TEC 27 COLD 60OUL 146 82 0.32 151 P3 TWD 13 DBC

+1.69 TEH TEC 27 COLD 60OUL 0.20 56 P2 TWO 9 03H

-0.63 TEH TEC 27 COLD 600UL 146 86 0.17 95 P2 TWD 8 08C

+0.87 TEH TEC 27 COLD 60OUL 0.14 82 P3 TWD 6 DBH

+1.87 TEH TEC 27 COLD 60OUL 0.18 99 P3 TWD 7 DBC

+1.77 TEH TEC 27 COLD 600UL 146 94 0.23 78 P2 TWD 10 02H

+0.87 TEH TEC 27 COLD 600UL 0.58 61 P2 TWD 22 VHI

+1.22 TEH TEC 27 COLD 600UL

AREVA NP Inc Customer Name: San Onofre -

Unit 2 01/09/08 14:19:37 Component:

S/G 88 Page 14 of 14 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryM![11.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 147 91 0.47 105 P2 TWD 19 VCl

-0.85 EXT EXT CAL # LEG TEH TEC 27 COLD PROBE 600UL Total Tubes

430 Total Records: 531

Inspection of Steam Generator Tubes Special Report Appendix 4 Page 1 of 16 Appendix 4 Tube Inspection Summary Steam Generator E-089

AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 2 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE

=============================

======

2 122 0.30 95 2

SAI 01H

+0.74 01H 01H 170 HOT 58OPP 3

127 0.41 113 2 SAI 07C

+0.01 07C 07C 108 COLD 58OPP 5

119 0.53 89 2

SAI 07H

-0.50 07H 07H 169 HOT 580PP 0.33 86 2

SAI 07H

-0.30 07H 07H 169 HOT 580PP 0.33 85 2

SAI 07C

+0.61 07C 07C 108 COLD 580PP 6

58 0.33 16 P1 SCI TSH

-6.31 TSH TSH 107 HOT 580PP 8

36 0.35 73 2

SAI 05H

-0.71 05H 05H 148 HOT 580PP 8

122 0.27 72 2

SAI 07H

-0.62 07H 07H 169 HOT 580PP 9

65 0.32 90 2

SAI 07H

+0.73 07H DBH 193 HOT 58OPP 9

117 0.26 93 2

SAI 05H

+0.91 05H 05H 170 HOT 580PP 10 44 0.31 75 2

SAI 05H

-0.83 05H 05H 145 HOT 58OPP 0.23 77 2

SAI 05H

+0.54 05H 05H 145 HOT 580PP 11 19 0.30 135 2 SAI 06H

+0.22 06H 06H 145 HOT 580PP 0.23 104 2 SAI 04H

-0.19 04H 04H 145 HOT 58OPP 11 55 0.37 101 2 SAI 05H

+0.94 05H 05H 157 HOT 580PP 11 65 0.30 67 2

SAI 01H

+0.54 01H 01H 203 HOT 58OPP 11 119 0.31 55 2

SAI 04H

-0.25 04H 04H 164 HOT 580PP 11 121 0.50 22 P1 SCI TSH

-10.71 TSH TSH 82 HOT 580PP 11 131 0.72 14 P1 SCI TSH

-13.59 TSH TSH 52 HOT 58OPP 12 114 0.40 130 2 SAI 06H

-0.16 06H 06H 215 HOT 520ET 12 128 0.22 121 2 SAI 01H

+0.58 01H 01H 168 HOT 58OPP 0.34 114 2 SAI 04H

+0.50 04H 04H 168 HOT 58OPP 13 37 0.20 33 P3 TWD 16 DBC

-0.09 TEC TEH 27 HOT 600UL 13 123 0.58 103 P2 TWD 22 07H

+0.62 TEH TEC 31 COLD 600UL 14 18 0.17 83 2

SAI 05H

+0.88 05H 05H 148 HOT 580PP 14 58 0.41 125 2 SAI 04H

+1.07 04H 04H 157 HOT 58OPP 15 131 0.43 19 P1 SCI TSH

-0.10 TSH TSH 52 HOT 58OPP 15 141 0.54 21 P1 SCI TSH

-0.08 TSH TSH 99 HOT 580PP 16 52 0.18 100 P3 TWD 11 DBH

-2.12 TEH TEC 34 COLD 600UL 16 56 0.12 96 2

SAI 06H

-1.39 06H 06H 157 HOT 58OPP 16 60 0.39 19 P1 SCI TSH

-0.09 TSH TSH 66 HOT 58OPP 17 27 0.13 27 P3 TWD 11 DBC

+1.54 TEC TEH 19 HOT 600UL 17 43 0.13 20 P3 TWD 11 DBH

-1.90 TEC TEH 27 HOT 600UL 17 49 0.13 110 P1 SCI TSH

+0.08 TSH TSH 71 HOT 58OPP 18 26 0.20 98 2

SAI 06H

-0.15 06H 06H 148 HOT 580PP 18 34 0.29 13 2

SAI TSH

-5.71 TSH TSH 85 HOT 580PP 0.48 16 2

SAI TSH

-5.26 TSH TSH 85 HOT 580PP 18 44 0.13 147 P3 TWD 11 DBH

-1.81 TEC TEH 27 HOT 600UL 18 122 0.36 110 P3 TWD 15 DBE

-1.89 TEH TEC 29 COLD 600UL 18 144 0.44 11 P3 TWD 19 DBh

+1.15 TEC TEN 14 HOT 600UL 19 109 0.23 124 P3 TWD 10 DBC

+1.33 TEH TEC 29 COLD 600UL 19 173 0.21 157 P2 TWD 12 VSM

+0.81 TEC TEH 22 HOT 60OUL 20 18 0.71 125 P2 TWD 26 VSm

-0.16 TEC TEH 16 HOT 600UL

AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 3 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMi[2].qry ROW LINE VOLTS DEG CHN IND

%TW LOCATION EXT EXT CAL # LEG PROBE

======-----------------------=---------------=====---==-------=-=-=-===-======-=------==-=----

20 108 0.17 122 P3 TWD 10 DBC

+1.77 TEH TEC 30 COLD 600UL 20 120 0.49 120 2 SAI 04H

+0.69 04H 04H 215 HOT 520ET 0.42 132 2 SAI 04H

-0.26 04H 04H 215 HOT 520ET 21 67 0.49 98 P2 TWD 22 VSM

+0.78 TEH TEC 36 COLD 600UL 22 2

0.33 129 P2 TWD 23 VSM

-0.91 TEC TEH 11 HOT 60OUL 22 50 5.84 186 4 PCS SBH

+3.47 TO+10.13 STH SBH 128 HOT 500SP 22 118 0.43 126 P2 TWD 21 07H

+1.07 TEH TEC 30 COLD 600UL 23 23 0.27 50 P2 TWD 13 07H

+0.60 TEC TEH 20 HOT 60OUL 23 115 0.38 137 P2 TWD 16 VSM

+0.75 TEH TEC 29 COLD 600UL 23 137 0.32 22 P1 SCI TSH

-0.14 TSH TSH 42 HOT 580PP 24 18 0.27 109 P2 TWD 12 VSM

-0.92 TEC TEH 16 HOT 600UL 24 50 0.23 103 P1 SCI TSH

+0.12 TSH TSH 72 HOT 58OPP 24 130 0.19 120 P1 SCI TSH

+0.08 TSH TSH 50 HOT 58OPP 24 154 0.18 49 P2 TWD 11 VSM

+0.25 TEC TEH 17 HOT 60OUL 25 49 0.16 95 P1 SCI TSH

+0.09 TSH TSH 71 HOT 580PP 25 51 0.32 100 2 SAI 07C

-0.60 07C 07C 109 COLD 58OPP 25 149 0.26 73 2

SAI 06H

-0.38 06H 06H 169 HOT 580PP 28 54 0.37 111 2 SAI TSH

+0.35 TSH TSH 71 HOT 58OPP 28 122 0.19 107 P1 MCI TSH

+0.12 TSH TSH 81 HOT 58OPP 29 47 0.30 102 2 SAI 07H

+0.61 07H 07H 161 HOT 580PP 29 59 0.32 17 2

SAI TSH

-3.59 TSH TSH 65 HOT 580PP 29 113 0.20 53 P3 TWD 12 DBH

-1.77 TEH TEC 30 COLD 600UL 30 70 0.35 136 P3 TWD 17 DBC

-1.46 TEH TEC 36 COLD 600UL 30 106 0.17 149 P3 TWD 10 DBC

-1.90 TEH TEC 30 COLD 600UL 30 134 0.47 20 P1 SCI TSH

-6.96 TSH TSH 50 HOT 58OPP 31 45 0.36 51 P3 TWD 14 DBH

+1.64 TEC TEH 31 HOT 600UL 31 71 0.60 79 P3 TWD 27 DBH

-2.04 TEH TEC 36 COLD 600UL 0.26 129 P3 TWD 13 DBC

+1.79 TEH TEC 36 COLD 600UL 0.25 142 P3 TWD 12 DBC

-1.83 TEH TEC 36 COLD 600UL 32 48 0.45 23 P1 SCI TSH

-0.09 TSH TSH 72 HOT 58OPP 33 67 0.26 83 2

SAI 04H

+0.50 04H 04H 205 HOT 58OPP 0.17 114 2 SAI TSH

+0.47 TSH TSH 64 HOT 58OPP 0.21 100 2 SAI TSH

+0.62 TSH TSH 64 HOT 580PP 34 112 0.28 83 2

SAT 04H

-0.34 04H 04H 159 HOT 58OPP 35 49 0.14 116 2 SAI TSH

+0.27 TSH TSH 72 HOT 580PP 35 111 0.72 16 2

SAI TSH

-0.98 TSH TSH 83 HOT 580PP 0.21 46 2

SAI 04H

-0.29 04H 04H 159 HOT 580PP 36 104 0.19 31 P3 TWD 11 DBC

-2.10 TEH TEC 30 COLD 600UL 36 114 0.35 112 P2 TWD 15 02H

+0.90 TEH TEC 29 COLD 60OUL 36 128 0.34 104 P1 MCI TSH

+0.05 TSH TSH 75 HOT 58OPP 37 101 0.30 103 P3 TWD 17 DBC

+1.75 TEH TEC 24 COLD 600UL 0.26 136 P3 TWD 15 DBH

+1.75 TEH TEC 24 COLD 60OUL 37 103 0.52 78 P3 TWD 19 DBH

-1.87 TEH TEC 29 COLD 600UL 0.45 39 P3 TWD 17 DBC

+1.74 TEH TEC 29 COLD 600UL

AREVA NP Inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 4 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[21.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE


=-------------------=-====--------------==--===-------------==-==---------------=

38 4

0.20 45 P2 TWD 16 01C

+0.06 TEC TEN 11 HOT 60OUL 0.23 36 P2 TWD 18 02C

-0.92 TEC TEN 11 HOT 600UL 38 8

0.23 93 2

SAI 06H

+0.70 06H 06H 148 HOT 58OPP 38 20 0.19 130 P3 TWD 14 DBH

+0.56 TEC TEN 19 HOT 600UL 38 104 0.25 68 P3 TWD 11 DBC

-1.76 TEH TEC 29 COLD 60OUL 39 45 0.18 107 P1 MCI TSH

+0.04 TSH TSH 80 HOT 580PP 39 101 0.28 106 P3 TWO 11 DBC

-2.00 TEN TEC 23 COLD 60OUL 0.24 55 P3 TWD 10 DBC

+1.94 TEN TEC 23 COLD 60OUL 39 115 0.27 14 P3 TWD 15 DEN

+1.94 TEN TEC 30 COLD 60OUL 39 131 0.60 15 2

SAI TSH

-7.50 TSH TSH 52 HOT 58OPP 0.47 14 2

SAI TSH

-8.54 TSH TSH 52 HOT 580PP 39 133 0.24 86 P1 SCI TSH

+0.03 TSH TSH 52 HOT 58OPP 0.73 21 2

SAI TSH

-7.28 TSH TSH 52 HOT 58OPP 40 46 0.25 101 P1 SCI TSH

+0.05 TSH TSH 80 HOT 580PP 40 60 0.33 110 2 SAI TSH

+0.31 TSH TSH 65 HOT 58OPP 40 74 0.43 123 P3 TWD 20 DBC

-1.64 STH TEC 38 COLD 600UL 40 136 0.51 25 P1 SCI TSH

-8.81 TSH TSH 99 HOT 58OPP 41 57 0.34 27 P3 TWD 13 DBH

+1.84 TEN TEC 33 COLD 600UL 41 63 0.48 58 P2 TWD 20 02H

+0.93 TEN TEC 35 COLD 60OUL 41 73 0.27 49 P3 TWD 14 DBC

-1.29 TEN TEC 36 COLD 60OUL 41 75 0.67 106 P3 TWD 22 DBC

+1.83 TEN TEC 35 COLD 60OUL 0.13 113 P3 TWD 6 DBC

-1.71 TEN TEC 35 COLD 60OUL 41 101 0.77 110 P3 TWD 25 DBC

+2.10 TEN TEC 23 COLD 600UL 41 113 0.24 25 P3 TWD 14 DBH

-1.86 TEN TEC 30 COLD 60OUL 41 119 0.42 71 P3 TWD 22 DBH

+1.88 TEN TEC 30 COLD 60OUL 41 131 0.57 18 P1 SCI TSH

-0.16 TSH TSH 50 HOT 58OPP 41 143 0.24 50 P2 TWD 14 VSM

+0.78 TEC TEH 13 HOT 60OUL 42 38 0.91 27 P1 SCI TSH

-0.12 TSH TSH 80 HOT 58OPP 42 168 0.54 156 P2 TWD 23 VSM

+0.90 TEC TEN 21 HOT 600UL 42 170 0.67 117 P2 TWD 27 VSM

-0.35 TEC TEN 22 HOT 60OUL 44 18 0.16 50 P2 TWD 7 VSM

+0.55 TEC TEN 16 HOT 600UL 0.32 128 P2 TWD 14 VSM

-0.92 TEC TEN 16 HOT 60OUL 44 74 0.67 59 P3 TWD 23 DBC

-2.14 TEN TEC 35 COLD 60OUL 0.23 67 P3 TWD 10 DBC

+2.00 TEN TEC 35 COLD 600UL 44 104 0.23 136 P3 TWD 13 DBH

+2.02 TEN TEC 30 COLD 60OUL 0.57 80 P2 TWD 25 VSM

+0.74 TEN TEC 30 COLD 600UL 0.13 12 P2 TWD 7 VSN

-1.04 TEN TEC 30 COLD 600UL 0.21 74 P3 TWD 13 DBE

-1.67 TEN TEC 30 COLD 600UL 44 112 0.53 142 P2 TWD 20 VSM

-0.80 TEN TEC 29 COLD 60OUL 45 63 0.26 78 2

SAI TSH

+0.19 TSH TSH 63 HOT 580PP 0.76 20 2

SAT TSH

-3.16 TSH TSH 63 HOT 580PP 0.53 21 2

SAI TSH

-2.39 TSH TSH 63 HOT 580PP 45 103 0.90 130 P2 TWD 29 VSE

+0.86 TEH TEC 29 COLD 600UL 0.39 131 P2 TWD 16 VSM

-0.80 TEN TEC 29 COLD 60OUL 0.26 144 P2 TWD 12 VSM

+0.00 TEN TEC 29 COLD 600UL 45 145 0.25 76 P2 TWD 15 VSM

-0.88 TEC TEN 13 HOT 600UL 46 48 0.13 103 P!

SCI TSH

+0.14 TSH TSH 71 HOT 580PP

AREVA N? Inc Customer Name: San Onofre -

Unit 2 1/9/2008 2:18i16 PM Component: S/G 89 Page 5 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2).qry ROW LTNE VOLTS DEG CHN IND %TW LOCATION

==

=== = = = = = = -

46 52 0.36 134 P2 TWD 15 VSM

-0.88 0.28 163 P2 TWD 12 VSM

+0.80 46 104 0.91 114 P2 TWD 29 VSM

-0.78 0.54 139 P2 TWD 21 VSM

+0.78 0.75 134 P2 TWD 26 VSM

+0.00 46 126 0.41 98 2

SAI 03H

-0.29 46 128 0.41 136 P2 TWD 17 VSM

-0.89 46 134 0.47 91 2

SAI 06H

+0.16 EXT EXT CAL # LEG PROBE TEN TEC 33 COLD 600UL TEH TEC 33 COLD 600UL TEH TEC 29 COLD 600UL TEN TEC 29 COLD 600UL TEH TEC 29 COLD 600UL 03H 03K 215 NOT 520ET TEH TEC 31 COLD 600UL 06H 06H 169 HOT 58OPP 46 156 0.66 115 P2 TWD 28 VSM

-0.87 TEC TEH 18 HOT 60OUL 0.13 152 P2 TWD 8 VSM

+0.77 TEC TEH 18 HOT 600UL 46 162 0.27 63 P2 TWD 15 VSM

+0.89 TEC TEH 22 HOT 60OUL 46 170 0.22 37 P3 TWD 13 DBC

+1.52 TEC TEH 22 HOT 600UL 47 29 0.32 16 P3 TWD 22 DBH

-1.78 TEC TEH 23 HOT 600UL 47 33 0.36 48 P3 TWD 23 DBH

+1.82 TEC TEH 23 HOT 600UL 47 53 0.23 93 P2 TWD 13 VSM

+0.83 STH TEC 38 COLD 600UL 47 117 0.30 51 P3 TWD 17 DBH

+1.93 TEH TEC 30 COLD 60OUL 47 121 0.21 159 P2 TWD 12 VSM

-0.86 TEH TEC 30 COLD 600UL 48 6

0.39 78 P2 TWD 25 08C

-1.72 TEC TEH 11 HOT 600UL 48 8

0.25 115 P2 TWD 12 02C

+0.89 TEC TEH 12 HOT 600UL 48 12 0.35 86 2

SAI 04H

+0.61 04H 04H 148 HOT 580PP 48 34 0.20 27 P2 TWD 9 VSM

-0.60 TEC TEH 24 HOT 600UL 48 52 0.15 131 P1 SCI TSH

+0.12 TSH TSH 71 HOT 580PP 48 64 0.43 14 2

SAI TSH

-2.18 TSH TSH 63 HOT 58OPP 0.37 13 2

SAI TSH

-1.43 TSH TSH 63 HOT 580PP 48 66 1.50 154 P2 TWD 38 VSM

-0.88 TEH TEC 35 COLD 600UL 48 100 0.63 24 P3 TWD 22 DBC

+1.90 TEH TEC 21 COLD 60OUL 48 118 0.47 40 P2 TWD 19 04H

-1.10 TEH TEC 29 COLD 600UL 48 130 0.36 18 P1 SCI TSH

-0.13 TSH TSH 50 HOT 580PP 48 158 0.55 167 P2 TWD 26 VSM

-0'.74 TEC TEH 17 HOT 600UL 0.09 160 P2 TWD 6 VSM

+0.97 TEC TEH 17 HOT 600UL 49 39 0.22 135 P2 TWD 10 VSM

-0.80 TEC TEH 28 HOT 600UL 49 51 0.15 66 P1 MCI TSH

+0.07 TSH TSH 71 HOT 58OPP 49 53 0.61 129 P2 TWD 23 08C

-1.51 TEH TEC 33 COLD 600UL 0.17 136 Pl SCI TSH

+0.09 TSH TSH 71 HOT 580PP 49 57 0.31 102 2 SAI 08H

+1.54 08H 08H 205 HOT 58OPP 49 65 0.31 135 P2 TWD 14 VSM

-0.71 TEH TEC 35 COLD 600UL 49 75 0.36 134 P3 TWD 14 DBC

-1.85 TEH TEC 35 COLD 600UL 49 103 0.41 153 P2 TWD 17 VSM

-0.80 TEH TEC 29 COLD 60OUL 49 145 0.54 49 159 0.58 0.27 0.12 50 16 0.15 50 44 0.20 102 P2 TWD 26 08H

-1.60 TEC TEH 133 P2 TWD 26 VSM

+0.76 TEC TEH 40 P2 TWD 15 VSM

+0.19 TEC TEH 92 P2 TWD 8 VSM

-1.05 TEC TEH

48. P2 TWD 7 08H

+1.23 TEC TEH 114 P2 TWD 15 VSM

-0.82 TEC TEH 13 HOT 600UL 18 NOT 600UL 18 HOT 600UL 18 HOT 60OUL 16 HOT 60OUL 27 HOT 600UL

AREVA NP inc 1/9/2008 2:18:16 PM Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 6 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE

=

====== = ----------

==

==

========

==

==

=

50 74 0.23 16 P3 TWD 9 DBC

+2.10 TEC TEH 45 HOT 600UL 0.21 75 P3 TWD 9 DBC

-2.00 TEC TEH 45 HOT 600UL 50 76 0.65 134 P3 TWD 23 DBC

-1.67 TEH TEC 23 COLD 600UL 50 100 0.38 121 P2 TWD 19 VSM

+0.12 TEH TEC 22 COLD 600UL 50 106 0.27 105 P1 SCI TSH

+0.15 TSH TSH 87 HOT 580PP 51 77 0.27 149 ?3 TWD 15 DBC

+1.93 TEH TEC 24 COLD 60OUL 51 153 0.40 68 P3 TWD 19 DBC

+0.62 TEC TEH 18 HOT 600UL 52 76 0.47 121 P3 TWD 23 DBC

-1.85 TEH TEC 24 COLD 60OUL 52 78 0.27 157 P3 TWD 11 DBC

-1.86 TEH TEC 23 COLD 600UL 52 80 0.80 92 P3 TWD 26 DBC

-1.86 TEH TEC 23 COLD 600UL 52 84 0.39 150 P3 TWD 15 DBC

-2.06 TEH TEC 23 COLD 600UL 0.64 126 P3 TWD 22 DBH

-1.45 TEH TEC 23 COLD 600UL 0.87 90 P3 TWD 27 DBH

+1.88 TEH TEC 23 COLD 60OUL 0.39 158 P3 TWD 15 DBC

+1.88 TEH TEC 23 COLD 600UL 52 96 0.25 164 P3 TWD 16 DBH

-1.69 TEH TEC 22 COLD 60OUL 52 120 0.62 24 P1 SCI TSH

-0.13 TSH TSH 82 HOT 580PP 52 158 0.50 91 P2 TWD 24 VH3

-0.96 TEC TEH 17 HOT 600UL 53 77 0.53 83 P3 TWD 19 DBC

-1.88 TEH TEC 23 COLD 60OUL 53 81 0.37 128 P3 TWD 15 DBC

-1.62 TEH TEC 23 COLD 60OUL 0.26 36 P3 TWD 10 DBH

-1.95 TEH TEC 23 COLD 600UL 53 91 0.38 90 P3 TWD 20 DBH

+1.79 TEH TEC 24 COLD 600UL 53 95 0.29 49 P3 TWD 17 DBH

+1.84 TEH TEC 22 COLD 60OUL 0.41 63 P3 TWD 22 DBC

+1.71 TEH TEC 22 COLD 600UL 53 155 0.34 46 P2 TWD 19 VH3

+0.47 TEC TEH 17 HOT 600UL 54 8

0.17 50 P2 TWD 14 01C

+0.10 TEC TEH 11 HOT 600UL 54 52 0.44 17 P1 SCI TSH

-5.76 TSH TSH 72 HOT 58OPP 54 102 0.27 90 2

SAI 01H

+13.43 01H 02H 215 HOT 520ET 54 148 0.41 93 P2 TWD 21 VH3

-0.82 TEC TEH 13 HOT 600UL 55 45 0.36 25 P1 SCI TSH

-0.16 TSH TSH 79 HOT 58OPP 55 79 0.37 29 P3 TWD 20 DEC

-2.00 TEH TEC 24 COLD 600UL 55 85 0.62 137 P3 TWD 22 DBH

+1.96 TEH TEC 23 COLD 60OUL 55 91 0.58 96 P3 TWD 21 DBC

+1.80 TEH TEC 23 COLD 60OUL 56 28 0.64 107 P2 TWD 24 VH3

-0.92 TEC TEH 24 HOT 600UL 56 92 0.37 122 P3 TWD 21 DBC

+1.92 TEH TEC 22 COLD 600UL 0.14 79 P3 TWD 10 DBC

-1.90 TEH TIC 22 COLD 600UL 56 150 0.41 105 P2 TWD 21 VH3

-0.91 TEC TEH 13 HOT 600UL 56 152 0.29

!!9 P3 TWD 18 DBH

+0.95 TEC TEH 13 HOT 600UL 56 158 0.48 90 P2 TWD 24 VH3

-0.76 TEC TEH 17 HOT 60OUL 57 77 0.25 92 Pl MCI TSH

+0.07 TSH TSH 53 HOT 580PP 57 79 0.46 29 P3 TWD 17 DBC

+1.80 TEH TEC 23 COLD 600UL 0.70 92 P3 TWD 24 DBC

-1.60 TEH TEC 23 COLD 600UL 57 97 0.50 15 2

SAI TSH

-4.39 TSH TSH 58 HOT 580PP 58 54 0.34 17 2

SAI TSH

-6.25 TSh TSH 71 HOT 58OPP 58 82 0.61 99 P3 TWD 22 DBH

+1.80 TEH TEC 23 COLD 600UL

AREVA NP Inc Customer Name:

San Onofre -

Unit 2 1/9/2608 2:18:16 PM Component:

S/G 89 Page 7 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW 58 LINE VOLTS 92 0.30 DEG CHN IND %TW LOCATION 17 P3 TWD 12 DBH EXT EXT CAL # LEG

+2.04 TEN TEC 21 COLD PROBE 600UL 58 94 0.41 78 P3 TWD 22 DBC 58 96 0.25 28 P3 TWD 10 DBH 0.30 94 P3 TWD 12 DEC 59 25 0.51 79 P2 TWD 21 VH3 59 53 0.25 24 P1 SCI TSH

-1.96

-1.68

-1.68

-1.00

-0.17 TEN TEC 22 COLD 600UL TEN TEC 21 COLD E0OUL TEN TEC 21 COLD 600UL TEC TEN 20 HOT 60OUL TSH TSH 71 HOT 58OPP 59 89 0.86 100 P3 TWD 32 DBH

-1.56 STN TEC 40 COLD 600UL 0.35 133 P2 TWD 18 VH3

+0.00 STH TEC 40 COLD 600UL 0.21 140 P2 TWD 12 VH3

-0.71 STH TEC 40 COLD 600UL 0.30 93 2

SAI 06C

-0.69 06C 06C 108 COLD 580PP 0.31 110 2 SAT VN3

+0.08 DBH VH3 120 COLD 560P2 59 95 0.46 118 P3 TWD 17 DBH

-1.56 TEN TEC 21 COLD 600UL 0.24 122 P3 TWD 9 DBC

+0.74 TEN TEC 21 COLD 600UL 59 147 0.60 106 P2 TWD 25 VH3

+0.93 TEC TEN 14 HOT 600UL 0.38 149 P2 TWD 18 VH3

-0.93 TEC TEN 14 HOT 600UL 60 28 0.33 126 P2 TWD 15 VH3

-0.98 TEC TEN 24 HOT 600UL 60 30 0.36 81 P2 TWD 16 VH3

-1.04 TEC TEN 24 HOT 600UL 60 88 0.77 139 P3 TWD 25 DBH

+1.74 TEN TEC 23 COLD 600UL 60 94 0.46 103 P3 TWD 17 DBH

+1.68 TEN TEC 21 COLD 60OUL 0.60 138 P3 TWD 21 DBC

-1.72 TEN TEC 21 COLD 60OUL 60 146 0.43 111 P2 TWD 22 VH3

-1.05 TEC TEN 13 HOT 600UL 60 158 0.35 122 P2 TWD 19 VH3

-0.99 TEC TEN 17 HOT 600UL 61 89 0.41 95 P3 TWD 21 DBC

-2.08 TEN TEC 24 COLD 600UL 0.29 115 P3 TWD 17 DBH

-1.85 TEN TEC 24 COLD 60OUL 61 91 0.60 14 P3 TWD 21 DBH

+1.97 TEN TEC 23 COLD 600UL 62 74 0.22 95 2

SAI TSH

+1.36 TSH TSH 62 HOT 58OPP 62 92 0.20 96 P1 SCI TSH

+0.13 TSH TSH 53 HOT 58OPP 63 87 0.55 110 P3 TWD 24 DBH

-1.49 STH TEC 40 COLD 600UL 0.18 149 P3 TWD 10 DBC

-1.78 STH TEC 40 COLD 600UL 63 99 0.23 55 P3 TWD 10 DBC

-1.33 TEN TEC 21 COLD 600UL 63 145 0.33 116 P2 TWD 18 VH3

+0.84 TEC TEN 13 HOT 600UL 64 10 0.36 109 P2 TWD 23 03C

-0.94 TEC TEN 15 HOT 600UL 0.07 45 P3 TWD 6 DBH

+1.67 TEC TEN 15 HOT 600UL 64 12 0.42 101 P2 TWD 25 VH3 64 76 0.28 111 2 SAI 05H

+0.66

+0.67 TEC TEN 15 HOT 600UL 05H 05H 146 HOT 580PP 64 80 0.35 15 2

SAI TSH

-2.87 TSH TSH 54 HOT 580PP 64 82 0.56 113 P3 TWD 26 DBC

+2.01 TEN TEC 24 COLD 600UL 64 84 0.19 86 P1 SCI TSH

+0.09 TSH TSH 54 HOT 580PP 0.36 65 P3 TWD 19 DBH

+1.75 TEN TEC 24 COLD 600UL 64 86 0.30 66 P3 TWD 16 DBH

-1.70 STH TEC 40 COLD 600UL 64 92 0.19 136 P3 TWD 11 DBH

-1.72 STH TEC 40 COLD 600UL 0.15 68 P3 TWD 9 DBC

-1.79 STH TEC 40 COLD 600UL 64 94 0.34 85 P3 TWD 19 DBC

-1.88 TEN TEC 22 COLD 600UL 64 150 0.34 147 P2 TWD 19 VH3

-0.93 TEC TEN 13 HOT 60OUL 65 37 0.21 89 2

SAI VSM

-0.93 66 78 0.29 87 P3 TWD 16 DBH

+1.91 66 80 0.44 116 P3 TWD 17 DEC

+1.89 VSM VSM 189 HOT 560P2 TEN TEC 24 COLD 600UL TEH TEC 23 COLD 600UL

AREVA NP Inc Customer Name: San Onofre -

Unit 2 1/9/2008 2:18:17 PM Component:

S/G 89 Page 8 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMil[2].qry ROW LINE VOLTS DEG CNN IND %TW LOCATION EXT EXT CAL # LEG PROBE 66 84 0.24 21 P3 TWD 10 DBH

-1.80 TEH TEC 23 COLD 600UL 66 90 0.31 14 P3 TWD 17 DEC

-1.79 TEH TEC 24 COLD 60OUL 66 94 0.58 58 P3 TWD 20 DEC

+1.74 TEH TEC 21 COLD 60OUL 0.36 127 P3 TWD 14 DEC

-1.70 TEH TEC 21 COLD 60OUL 66 138 0.32 90 P2 TWD 16 08C

-0.90 TEC TEH 10 HOT 60OUL 67 83 0.79 74 P3 TWD 26 DEC

-1.76 TEH TEC 23 COLD 600UL 0.38 57 P3 TWD 15 DBH

-1.66 TEH TEC 23 COLD 60OUL 67 87 0.29 107 P2 TWD 11 VSM

+0.88 TEH TEC 23 COLD 600UL 0.30 161 P3 TWD 12 DBH

+1.53 TEH TEC 23 COLD 60OUL 68 40 0.22 151 P2 TWD 16 VC3

+0.87 TEC TEH 27 HOT 60OUL 68 90 0.66 121 P3 TWD 23 DEC

-2.00 0.39 41 P3 TWD 15 DBH

-1.92 0.36 16 P3 TWD 14 DEC

+2.25 69 91 0.32 97 P3 TWD 13 DEC

+2.17 69 163 0.28 148 P2 TWD 15 02C

+0.89 70 24 0.21 166 P3 TWD 8 DEC

+2.05 0.16 16 P3 TWD 6 DEC

-1.48 TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEH TEC 23 COLD 600UL TEC TEH 22 HOT 600UL TEC TEH 20 HOT 600UL TEC TEH 20 HOT 600UL 70 52 0.37 153 P3 TWD 22 DEC

+1.29 TEC TEH 40 HOT 600UL 70 68 0.24 79 P1 SCI TSH

+0.06 TSH TSH 63 HOT 58OPP 70 90 0.21 146 P3 TWD 13 DBH

-1.88 TEH TEC 24 COLD 600UL 70 92 0.29 20 2

SAI TSH

-2.27 TSH TSH 54 HOT 58OPP 70 94 0.57 124 P3 TWD 20 DEC

-1.85 TEH TEC 21 COLD 600UL 70 144 0.39 119 P2 TWD 19 VC3

-0.86 TEC TEH 14 HOT 600UL 0.36 32 P2 TWD 17 VSM

-0.89 TEC TEH 14 HOT 60OUL 70 152 0.37 141 P2 TWD 18 VH3

-0.76 TEC TEH 14 HOT 600UL 70 156 0.46 135 P2 TWD 23 VH3

-1.01 TEC TEH 18 HOT 600UL 70 164 0.32 72 P2 TWD 16 02C

-0.94 TEC TEH 21 HOT 60OUL 71 57 0.15 78 2

SAI 08H

+0.52 08H 08H 156 HOT 580PP 71 67 0.46 109 P1 SCI TSH

+0.14 TSH TSH 64 HOT 58OPP 71 79 0.44 114 P3 TWD 22 DEC

-2.20 TEH TEC 24 COLD 600UL 71 91 0.27 143 P3 TWD 16 DEC

-1.85 TEN TEC 24 COLD 600UL 71 93 0.21 129 P3 TWD 13 DEC

-2.18 TEH TEC 22 COLD 600UL 71 143 0.23 58 P2 TWD 12 04C

-0.14 TEC TEN 14 NOT 600UL 0.22 159 P2 TWD 12 VC3

-0.88 TEC TEH 14 HOT 600UL 0.38 143 P2 TWD 18 VN3

-0.88 TEC TEH 14 HOT 600UL 0.42 134 P2 TWD 19 VSM

+0.70 TEC TEH 14 HOT 600UL 71 147 0.37 127 P2 TWD 18 VC3

-0.82 TEC TEH 14 HOT 60OUL 0.62 101 P2 TWD 25 VH3

-0.92 TEC TEH 14 HOT 600UL 72 26 0.46 101 P2 TWD 19 VC3

+0.80 TEC TEH 20 HOT 600UL 72 28 0.21 153 P3 TWD 10 DEC

+0.71 TEC TEH 24 HOT 600UL 72 36 0.18 9

P3 TWD 9 DEC

+1.46 TEC TEH 24 HOT 600UL 72 38 0.26 92 P3 TWD 19 DEC

+1.98 TEC TEH 27 HOT 600UL 72 78 0.27 77 P2 TWD 11 VC3

+0.88 TEH TEC 23 COLD 60OUL 0.33 134 P2 TWD 13 VH3

+0.80 TEH TEC 23 COLD 600UL 0.58 82 P2 TWD 20 VH3

-0.99 TEH TEC 23 COLD 60OUL 72 80 0.47 145 P2 TWD 17 VC3

+0.84 TEH TEC 23 COLD 600UL

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 9 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAT, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CNN TD %TW LOCATION EXT EXT CAL 4 LEG PROBE 72 84 0.39 130 P3 TWD 15 DEC

-1.78 TEH TEC 23 COLD 60OUL 0.37 130 P2 TWD 14 VH3

-0.84 TEH TEC 23 COLD 60OUL 72 90 0.39 94 P3 TWD 15 DEC

-2.22 TEN TEC 23 COLD 600UL 72 114 0.26 84 P2 TWD 14 VC3

+0.87 TEC TEH 32 HOT 60OUL 72 126 0.44 127 P2 TWD 22 VSM

-0.82 TEC TEH 33 HOT 600UL 0.42 104 P2 TWD 21 VH3

-0.12 TEC TEH 33 HOT 600UL 72 156 0.24 107 P2 TWD 14 VC3

-0.93 TEC TEH 17 HOT 600UL 73 13 0.25 85 P2 TWD 18 VH3

+0.80 TEC TEH 15 HOT 60OUL 73 51 0.30 142 P3 TWD 19 DBH

-1.10 TEC TEH 40 HOT 600UL 73 91 0.47 21 P3 TWD 18 DEC

+2.21 TEH TEC 23 COLD 60OUL 73 157 0.31 131 P2 TWD 17 VH3

+1.09 TEC TEH 17 HOT 600UL 73 163 0.13 44 P3 TWD 6 DEC

+1.54 TEC TEH 21 HOT 60OUL 74 18 0.13 152 P3 TWD 11 DEC

+2.06 TEC TEH 15 HOT 600UL 74 44 0.16 71 P2 TWD 12 VSM

+0.76 TEC TEH 27 HOT 600UL 0.50 133 P2 TWD 27 VH3

-0.80 TEC TEH 27 HOT 60OUL 74 50 0.32 161 P3 TWD 20 DBH

+1.89 TEC TEN 40 HOT 60OUL 74 56 0.23 49 P3 TWD 9 DBH

+0.97 TEC TEH 41 HOT 60OUL 74 90 0.41 123 P3 TWD 21 DEC

-1.75 TEH TEC 24 COLD 600UL 74 94 0.20 35 P3 TWD 12 DBH

-1.63 TEH TEC 22 COLD 60OUL 74 124 0.20 96 P3 TWD 9 DEC

-1.77 TEC TEH 33 HOT 600UL 74 132 0.28 103 P2 TWD 15 VC3

-0.99 TEC TEH 10 HOT 600UL 74 148 0.31 126 P2 TWD 18 VSM

-0.95 TEC TEH 13 HOT 600UL 0.44 55 P2 TWD 22 VH3

-0.93 TEC TEH 13 HOT 600UL 74 156 0.59 46 P2 TWD 26 VC3

-0.76 TEC TEH 18 HOT 600UL 0.41 87 P2 TWD 21 VSM

-0.85 TEC TEH 18 HOT 60OUL 0.57 95 P2 TWD 26 VH3

-0.87 TEC TEH 18 HOT 600UL 75 15 0.10 162 P3 TWD 8 DBH

+1.29 TEC TEH 11 HOT 600UL 75 23 0.14 46 P3 TWD 12 DEC

+1.69 TEC TEH 19 HOT 600UL 75 51 0.15 94 P3 TWD 6 DBH

-2.24 TEC TEH 41 HOT 60OUL 75 53 0.12 91 P1 SCI TSH

-0.03 TSH TSH 71 HOT 58OPP 75 83 0.51 54 P3 TWO 19 DEC

-2.01 TEN TIC 23 COLD 600UL 75 87 0.51 19 P3 TWD 19 DEC

+2.25 TEH TEC 23 COLD 600UL 0.70 119 P3 TWD 24 DEC

-2.23 TEH TEC 23 COLD 600UL 75 97 0.23 85 P2 TWD 13 VC3

-0.88 TEH TEC 22 COLD 600UL 0.34 105 P2 TWD 18 VC3

+0.90 TEH TEC 22 COLD 60OUL 75 103 0.19 139 P2 TWD 11 VC3

+0.91 TEC TEH 38 HOT 600UL 76 42 0.22 126 P3 TWD 16 DEC

-1.79 TEC TEH 27 HOT 600UL 76 56 0.32 21 P3 TWD 20 DBH

+1.18 TEC TEH 40 HOT 600UL 76 78 0.27 143 P2 TWD 15 VC3

-0.86 TEH TEC 24 COLD 600UL 0.55 125 P2 TWD 25 VC3

+0.86 TEH TEC 24 COLD 600UL 0.26 117 P2 TWD 15 VH3

+0.84 TEH TEC 24 COLD 600UL 76 84 0.37 5

P3 TWD 15 DEC

+2.15 TEI TEC 23 COLD 60OUL 76 90 0.42 118 P3 TWD 16 DEC

-2.00 TEH TEC 23 COLD 600UL 0.30 33 P3 TWD 12 DBC

+2.15 TEH TEC 23 COLD 600UL 76 114 0.38 78 P2 TWD 19 VH3

-0.87 TEC TEH 32 HOT 600UL 76 138 0.14 14 P3 TWD 8 DEC

+1.93 TEC TEH 9

HOT 600UL

AREVA NP Inc Customer Name: San Onofre -

Unit 2 1/9/2008 2:18:17 PM Component:

S/G 89 Page 10 of 16 Post U2C1S Inspection Final Report MAT, MCI, MMI, MVI, SAT, SCI, SVI, 0-100%, PCS QUERY: QueryMi [2[.ary ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 76 142 0.21 91 P2 TWD 13 08C

-0.49 TEC TEH 13 HOT 600UL 76 160 0.43 74 P2 TWD 22 VH3

+0.84 TEC TEH 17 HOT 600UL 77 27 0.24 80 P3 TWD 10 DBC

-1.69 TEC TEH 20 HOT 600UL 77 43 0.30 124 22 TWD 13 VH3

+0.78 TEC TEH 28 HOT 60OUL 77 113 0.18 103 P2 TWD 11 VH3

-1.04 TEC TEH 33 HOT 60OUL 77 137 0.64 98 P2 TWD 26 VSM

-0.90 TEC TEH 10 HOT 60OUL 77 139 0.60 132 P2 TWD 25 VC3

+0.77 TEC TEH 10 HOT 60OUL 0.25 99 P2 TWD 13 VC3

-0.90 TEC TEH 10 HOT 600UL 0.33 61 P2 TWD 17 VSM

-0.92 TEC TEH 10 HOT 600UL 0.31 105 P2 TWD 16 VH3

-1.03 TEC TEH 10 HOT 600UL 77 157 0.38 75 P2 TWD 20 VH3

-0.95 TEC TEH 17 HOT 60OUL 78 26 0.24 130 P2 TWD 18 07C

-0.14 TEC TEH 19 HOT 600UL 78 28 0.07 138 P3 TWD 6 DBC

-1.65 TEC TEH 23 HOT 600UL 78 44 0.33 127 P2 TWD 21 VSM

-0.78 TEC TEH 27 HOT 600UL 78 58 0.24 173 P3 TWD 16 DBH

+1.61 TEC TEH 40 HOT 60OUL 78 130 0.31 132 P2 TWD 15 VSM

-1.02 TEC TEH 10 HOT 60OUL 78 136 0.26 144 P2 TWD 14 VC3

-0.89 STH TEC 38 COLD 600UL 78 150 0.57 64 P2 TWD 24 VH3

-0.74 TEC TEH 14 HOT 60OUL 78 160 0.30 124 P3 TWD 15 DBC

-1.56 TEC TEH 18 HOT 60OUL 79 15 0.13 117 P3 TWD 10 DBH

+1.21 TEC TEN 11 HOT 600UL 79 43 0.23 45 P2 TWD 16 VH3

-0.62 TEC TEH 27 HOT 600UL 79 53 0.57 21 P1 SCI TSH

-0.02 TSH TSH 71 HOT 580PP 79 79 0.41 143 P2 TWD 16 VH3

-0.92 TEH TEC 23 COLD 600UL 79 89 0.17 108 2 SAI TSH

+1.00 TSH TSH 53 HOT 58OPP 79 99 0.33 125 P1 SCI TSH

-0.00 TSH TSH 57 HOT 580PP 80 72 0.20 88 P3 TWD 15 DBH

-2.24 TEC TEH 44 HOT 600UL 80 106 0.29 78 P2 TWD 16 VH3

+0.91 TEC TEH 32 HOT 600UL 80 152 0.59 108 P2 TWD 27 VC3

+0.86 0.67 105 P2 TWD 29 VC3

-0.80 0.33 123 P2 TWD 18 VSM

+0.86 0.52 137 P2 TWD 25 VSM

-0.82 80 160 0.63 117 P3 TWD 27 DBC

-1.59 81 21 0.15 87 P3 TWD 12 DBE

+0.78 81 25 0.13 158 P3 TWD 10 DBC

-1.38 81 75 0.34 125 22 TWD 17 VC3

+0.86 0.27 81 79 0.94 0.37 24 P3 TWD 13 100 P2 TWD 30 124 P2 TWD 15 DBH VH3 VC 3 TEC TEH 13 HOT 60OUL TEC TEH 13 HOT 600UL TEC TEH 13 HOT 600UL TEC TEH 13 HOT 600UL TEC TEH 17 HOT 600UL TEC TEN 11 NOT 600UL TEC TEH 11 HOT 600UL TEN TEC 17 COLD 600UL TEN TEC 17 COLD 600UL TEH TEC 13 COLD 60OUL TEH TEC 13 COLD 60OUL TEN TEC 9

COLD 6000L TEH TEC 9

COLD 600UL TEC TEN 5

NOT 600UL TEC TEN S

NOT D 60UL TEC TEH 9

HOT 60OUL TEC TEH 9

POT 600UL 81 105 0.55 148

?2 TWD 21 VH3

+0.99 0.29 114 P2 TWD 12 VSM

+0.87 81 135 0.41 123 P2 TWD 20 VH3

+0.92 0.24 157 P2 TWD 14 VH3

-0.73 81 159 0.33 72 P2 TWD 17 VH3

-0.87 0.26 87 P2 TWD 14 02H

-0.36 82 28 0.20 92 P2 TWD 16 VH3

-0.19 0.23 99 22 TWD 18 VH3

-0.68 TEC TEH 11 HOT TEC TEH 11 HOT 600UL - -- --

600UL

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 11 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 82 44 0.22 138 P2 TWD 13 VH3

+0.91 TEC TER 7

HOT 600UL 82 68 0.42 140 P2 TWD 20 VH3

+0.86 TEH TEC 17 COLD 600UL 0.89 127 P2 TWD 32 VH3

-0.86 TEM TEC 17 COLD 60OUL 82 148 0.61 125 P2 TWD 26 VH3

-0.89 TEC TEH 9

HOT 600UL 83 73 0.29 111 2 SAI 03H

-0.11 03H 03H 171 HOT 580PP 84 40 0.38 64 P2 TWD 22 VH2

-1.14 TEC TEH 8

HOT 600UL 84 100 0.47 66 P2 TWD 22 09H

-1.59 TEH TEC 12 COLD 60OUL 84 108 0.40 127 P2 TWD 19 09H

+0.39 TEH TEC 10 COLD 600UL 85 81 0.31 102 P1 SCI TSH

+0.19 TSH TSH 107 HOT 580PP 85 91 0.25 93 P3 TWD 9 DBC

-1.85 TEN TEC 11 COLD 60OUL 86 68 0.37 42 P2 TWD 19 VH2

+0.82 TEN TEC 17 COLD 60OUL 86 130 0.37 114 P2 TWD 19 VH2

-0.77 TEC TEH 5

HOT 600UL 87 31 0.82 19 2

SAI 05H

+0.33 05H 05H 143 HOT 580PP 87 47 0.18 105 2 SAT 03H

-0.21 03H 03H 165 HOT 58OPP 87 131 0.35 122 P2 TWD 18 VH2

+0.66 TEC TEH 5

HOT 600UL 88 40 0.23 76 P2 TWD 14 VSM

-0.93 TEC TEH 8

HOT 60OUL 89 25 0.14 36 P3 TWD 11 DBH

+0.04 TEC TEH 11 HOT 600UL 89 93 0.48 17 2

SAI TSH

-13.00 TSH TSH 113 HOT 580PP 90 122 0.38 140 P2 TWD 19 VH2

-0.78 TEN TEC 8

COLD 60OUL 91 85 0.33 104 2

SAI 03H

+0.20 03H 03H 176 HOT 580PP 93 113 0.35 67 2

SAT 02H

+0.84 02H 02H 174 HOT 580PP 94 22 0.23 93 P2 TWD 11 02C

+0.93 TEC TEN 12 HOT 60OUL 94 50 0.33 133 P2 TWD 14 05C

-0.12 TEN TEC 21 COLD 60OUL 94 146 0.23 124 P2 TWD 14 VH3

-0.96 TEC TER 5

HOT 600UL 97 37 0.50 115 P2 TWD 26 VC3

+0.95 TEC TEH 8

HOT 600UL 98 62 1.26 20 2

SAI TSH

-13.92 TSH TSH 101 HOT 580PP 98 82 0.31 100 2 SAI 01H

-0.44 01H 01H 176 HOT 58OPP 99 131 0.30 124 P2 TWD 16 VH2

+0.73 TEC TEH 5

HOT 600UL 101 25 0.33 118 P2 TWD 15 08H

+0.47 TEC TEN 12 HOT 600UL 101 33 0.20 20 P3 TWD 12 DBC

+2.00 TEC TEN 7

HOT 600UL 101 39 0.32 99 P2 TWD 19 VH2

+0.85 TEC TEH 8

HOT 600UL 101 143 0.24 121 P3 TWD 15 DBH

+1.84 TEC TEH 5

HOT 600UL 102 58 0.38 124 P2 TWD 16 VH3

+0.86 TEN TEC 19 COLD 600UL 0.25 109 P2 TWD 11 VC3

+0.86 TEN TEC 19 COLD 60OUL 0.21 150 P2 TWD 10 VC3

-0.82 TEH TEC 19 COLD 600UL 0.25 125 P2 TWD 11 VC2

-0.89 TEN TEC 19 COLD 60OUL 103 137 0.39 92 P2 TWD 20 VH3

-0.92 TEC TEH 6

HOT 60OUL 105 61 0.20 141 P2 TWD 11 VC3

-0.80 TEN TEC 20 COLD 600UL 105 141 0.19 148 P3 TWD 12 DBH

+1.78 TEC TEN 5

HOT 600UL 106 84 0.34 120 P2 TWD 15 VH3

+0.80 TEH TEC 13 COLD 600UL 106 126 0.44 94 2

MAI 02H

+0.24 02H 02H 174 HOT 580P?

107 33 0.21 38 P3 TWD 16 DBC

+1.65 TEC TER 7

HOT 60OUL

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:

San Onofre -

Unit 2 Component:

S/G 89 Page 12 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: Querytl [2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 107 35 0.25 128 P3 TWD 16 DBC

+2.00 TEC TEH 7

HOT 600UL 107 59 0.32 60 P3 TWD 17 DBH

+1.77 TEH TEC 20 COLD 600UL 107 103 0.51 70 P2 TWD 23 VH2

-0.89 TEH TEC 12 COLD 60OUL 108 42 0.35 104 P3 TWD 13 DBH

+1.86 TEC TEH 8

HOT 60OUL 0.35 127 P3 TWD 13 DBH

-2.25 TEC TEH 8

HOT 60OUL 108 52 1.22 16 2

SAI 06H

+0.67 06H 06H 165 HOT 580PP 108 126 0.33 91 2

SAI 02H

+0.66 02H 02H 174 HOT 580PP 109 47 0.31 130 P2 TWD 17 VSM

-0.58 TEH TEC 22 COLD 600UL 0.29 47 P2 TWD 16 VC3

-0.70 TEH TEC 22 COLD 60OUL 109 55 0.25 133 P3 TWD 14 DBH

+1.48 TEH TEC 20 COLD 60OUL 110 34 0.28 140 P2 TWD 17 VH2

+0.76 TEC TEH 7

HOT 600UL 110 122 0.30 88 2

SAI 02H

+0.82 02H 02H 174 HOT 580PP 111 43 0.35 95 P2 TWD 21 VH3

-0.95 TEC TEH 8

HOT 60OUL 111 87 0.43 95 P2 TWD 17 VC2

+0.91 TEH TEC 13 COLD 60OUL 11 99 0.47 56 P2 TWD 17 09C

+0.51 TEH TEC 11 COLD 60OUL 112 32 0.32 122 P3 TWD 12 DBC

+1.80 TEC TEH 8

HOT 60OUL 112 134 0.54 97 2

SAI 02H

+0.50 02H 02H 174 HOT 580PP 112 144 0.46 51 P3 TWD 21 DBC

+2.05 TEC TEH 6

HOT 60OUL 113 53 0.24 78 P2 TWD 13 VC2

-0.52 TEH TEC 22 COLD 600UL 113 77 0.31 114 P2 TWO 13 VC3

+0.92 TEN TEC 13 COLD 6--UL 113 91 0.31 121 P2 TWD 16 VC3

-0.84 TEH TEC 12 COLD 600UL 113 105 0.40 79 P2 TWD 19 VN2

+0.79 TEH TEC 10 COLD 60OUL 0.33 73 P2 TWD 17 VH3

+0.81 TEH TEC 10 COLD 60OUL 113 125 0.23 23 P2 TWD 13 05H

-0.18 TEN TEC 8

COLD 600UL 114 36

  • 0.22 76 P2 TWD 13 09C

-1.01 TEC TEH 7

HOT 600UL 0.12 21 P3 TWD 10 DBC

-1.98 TEC TEH 7

HOT 60OUL 114 40 0.35 67 P3 TWD 21 DBH

+1.51 TEC TEH 7

HOT 600UL 114 62 0.32 135 P3 TWD 13 DBH

-1.77 TEH TEC 19 COLD 60OUL 114 136 0.31 147 P2 TWD 17 VC3

+0.67 TEC TEH 6

HOT 60OUL 115 39 0.75 134 P2 TWD 28 VHI

+0.81 TEC TEH 8

HOT 60OUL 115 43 0.65 144 P2 TWD 26 VHI

+0.83 TEC TEH 8

HOT 60OUL 0.64 161 P2 TWD 25 VH1

-0.70 TEC TEH 8

HOT 60OUL 115 107 0.26 127 P3 TWD 11 DBH

-1.38 TEH TEC 9

COLD 600UL 116 50 0.25 61 P2 TWD 11 VH2

-1.15 TEH TEC 21 COLD 600UL 116 90 0.47 79 P2 TWD 21 VH1

-1.13 TEH TEC 14 COLD 600UL 116 102 0.64 38 P2 TWD 22 VHN

-0.69 TEH TEC 11 COLD 600UL 116 128 0.46 77 P3 TWD 22 DBH

-1.66 TEH TEC 8

COLD 600UL 116 140 0.24 104 P3 TWD 13 DBH

-1.50 TEC TEH 6

HOT 600UL 117 59 0.37 22 P3 TWD 19 DBH

-1.18 TEH TEC 20 COLD 600UL 117 129 0.42 131 P2 TWD 18 05H

-0.16 TEH TEC 7

COLD 60OUL 118 62 0.41 98 2

SAI 01H

+0.95 01H 01H 171 NOT 580PP 0.25 110 2

SAI 04H

+0.95 04H 04H 171 HOT 58OPP 118 124 0.23 78 2

SAI 02H

+0.43 02H 02H 174 HOT 580PP

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name: San Onofre -

Unit 2 Component:

S/G 89 Page 13 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 118 128 0.29 101 P2 TWD 13 05H

+0.70 TEH TEC 7

COLD 600UL 119 79 0.68 132 P2 TWD 24 VH3

+0.86 TEH TEC 13 COLD 600UL 119 119 0.42 30 P2 TWD 18 10H

-1.08 TEH TEC 7

COLD 600UL 119 121 0.53 98 P2 TWD 21 10H

-1.20 TEH TEC 7

COLD 60OUL 120 38 0.23 66 P2 TWD 15 10H

+1.05 TEC TEH 8

HOT 600UL 120 72 0.23 61 P2 TWD 13 10H

-1.02 TEH TEC 17 COLD 600UL 120 98 0.48 80 P2 TWD 23 VHl

-0.80 TEH TEC 12 COLD 600UL 121 39 0.27 100 P2 TWD 17 10H

-1.44 TEC TEH 8

HOT 600UL 121 45 0.62 108 P2 TWD 29 VC2

-0.62 TEC TEH 8

HOT 60OUL 121 47 0.31 113 P2 TWD 16 10H

+0.76 TEH TEC 22 COLD 600UL 121 83 0.53 125 P2 TWD 23 VC3

-0.88 TEH TEC 14 COLD 60OUL 0.38 134 P2 TWD 18 VHl

+0.84 TEH TEC 14 COLD 60OUL 121 109 0.87 88 P2 TWD 31 10H

-1.50 TEH TEC 10 COLD 600UL 122 110 0.23 102 2 SAI 05H

-0.30 05H 05H 174 HOT 58OPP 123 45 0.29 17 P3 TWD 18 DBH

+2.02 TEC TEH 7

HOT 600UL 123 117 0.31 141 23 TWD 12 DBH

-1.90 TEH TEC 9

COLD 600UL 124 58 0.54 128 P2 TWD 24 VHl

-0.78 TEH TEC 20 COLD 600UL 124 98 0.26 7

P3 TWD 14 DBH

+1.86 TEH TEC 12 COLD 60OUL 125 53 0.31 133 P2 TWD 17 VHl

-0.79 TEH TEC 22 COLD 600UL 125 55 0.21 117 P3 TWD 12 DBH

+1.69 TEH TEC 20 COLD 600UL 125 77 0.42 128 P2 TWD 20 VHl

+0.92 TEH TEC 14 COLD 600UL 125 111 0.25 168 P3 TWD 14 DBH

+1.69 TEH TEC 10 COLD 600UL 125 119 0.30 109 P3 TWD 16 DBH

+1.62 TEH TEC 8

COLD 60OUL 126 74 0.31 84 P2 TWD 17 VHl

-1.06 TEH TEC 17 COLD 60OUL 126 86 0.24 110 P3 TWD 9 DBH

-1.90 TEH TEC 13 COLD 600UL 126 102 0.26 24 P3 TWD 14 DBH

-1.26 TEH TEC 12 COLD 600UL 126 108 0.27 162 P3 TWD 11 DBH

-1.64 TEH TEC 9

COLD 600UL 127 71 0.41 142 P2 TWD 20 04H

+0.89 TEH TEC 17 COLD 600UL 127 99 0.39 151 P2 TWD 15 VHl

+0.84 TEH TEC 11 COLD 600UL 127 111 0.33 25 P2 TWD 14 04H

+0.20 TEH TEC 9

COLD 600UL 127 123 0.34 97 P2 TWD 15 09C

-1.20 TEH TEC 7

COLD 60OUL 128 56 0.23 168 P3 TWD 10 DBH

+2.04 TEH TEC 19 COLD 600UL 128 60 0.42 95 2

SAI 04H

+0.75 04H 04H 166 HOT 580PP 128 72 0.32 92 P2 TWD 17 10H

+0.94 TEH TEC 17 COLD 600UL 0.61 120 P2 TWD 26 10H

+0.08 TEH TEC 17 COLD 600UL 0.69 144 P2 TWD 28 iOH

-1.19 TEH TEC 17 COLD 600UL 128 92 0.52 43 22 TWO 19 06H

+0.93 TEN TEC i1 COLD 60OUL 129 47 0.48 141 P2. TWD 23 10H

+0.83 TEH TEC 22 COLD 600UL 0.42 130 P3 TWD 22 DBH

+1.67 TEH TEC 22 COLD 600UL 0.39 47 P3 TWD 21 DBH

-1.32 TEH TEC 22 COLD 600UL 129 49 0.44 90 P2 TWD 21 VHI

-0.83 TEH TEC 22 COLD 600UL 0.32 90 P2 TWD 17 VHi

+0.91 TEH TEC 22 COLD 600UL 129 73 0.26 65 P3 TWO 16 DEN

+1.92 TEN TIC 18 COLD SOQUL--------------------

129 73 0.26 65 P3 TWD 16 DBE

+1.92 TEH TEC 18 COLD 600UL

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:

San Onofre -

Unit 2 Component: S/G 89 Page 14 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MVI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMi[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE


==-------------------=--=----------------

129 89 0.27 60 P2 TWD 14 VH2

-0.88 TEH TEC 14 COLD 600UL 0.23 154 P2 TWD 12 VH3

-0.86 TEH TEC 14 COLD 600UL 0.24 87 P2 TWD 12 VC3

-1.07 TEH TEC 14 COLD 60OUL 0.23 76 P2 TWD 12 VC3

+0.82 TEH TEC 14 COLD 600UL 0.26 100 P2 TWD 14 VH2

+0.88 TEH TEC 14 COLD 600UL 129 109 0.43 139 P2 TWD 20 10H

-1.05 TEH TEC 10 COLD 60OUL 130 48 0.35 68 P2 TWD 18 02C

-0.18 TEH TEC 22 COLD 600UL 130 74 0.37 99 P2 TWD 19 10H

+0.96 TEH TEC 17 COLD 600UL 130 78 0.30 93 P2 TWD 12 10H

-1.22 TEH TEC 13 COLD 600UL 130 82 0.67 82 2

SAI 01H

-0.27 01H 01H 176 HOT 580PP 130 86 0.50 111 P2 TWD 20 VHN

+0.87 TEH TEC 13 COLD 60OUL 130 88 0.46 109 P2 TWD 22 VH1

-0.88 TEH TEC 14 COLD 600UL 132 56 0.62 131 P2 TWD 26 VHN

-1.02 TEH TEC 17 COLD 600UL 132 74 0.30 108 P3 TWD 14 DBH

+1.70 TEH TEC 17 COLD 600UL 132 106 0.71 125 P2 TWD 26 10H

-1.09 TEH TEC 15 COLD 60OUL 133 55 0.28 75 P2 TWD 15 02H

+0.22 TEH TEC 17 COLD 60OUL 133 81 0.58 130 P2 TWD 23 VHN

+0.90 TEH TEC 15 COLD 60OUL 133 119 0.57 114 P2 TWD 24 VHN

+0.92 TEH TEC 16 COLD 600UL 133 125 0.35 91 P2 TWD 17 01C

+0.88 TEH TEC 16 COLD 60OUL 134 64 0.31 98 P2 TWD 16 VH3

-0.90 TEH TEC 18 COLD 600UL 0.34 139 P2 TWD 17 VC3

-0.84 TEH TEC 18 COLD 600UL 134 76 0.39 78 P2 TWD 18 VHN

-0.86 TEH TEC 16 COLD 600UL 0.28 11 P3 TWD 14 DBH

+2.19 TEH TEC 16 COLD 600UL 134 80 0.29 6

P3 TWD 15 DBH

+2.04 TEH TEC 16 COLD 600UL 134 124 0.23 119 P2 TWD 12 VC3

+0.65 01C TEH 132 HOT 60OUL 135 67 0.34 84 P3 TWD 16 DBH

-1.62 TEH TEC 17 COLD 60OUL 135 71 0.23 161 P3 TWD 14 DBH

-1.80 TEH TEC 18 COLD 600UL 136 68 0.54 111 P2 TWD 24 VHN

-0.88 TEH TEC 17 COLD 600UL 0.33 95 P2 TWD 17 VH1

-1.13 TEH TEC 17 COLD 600UL 136 76 0.27 9

23 TWD 14 DBH

+1.85 TEH TEC 16 COLD 600UL 136 78 0.23 123 P3 TWD 12 DBH

+1.79 TEH TEC 16 COLD 600UL 0.31 48 P2 TWD 15 VH1

+0.72 TEH TEC 16 COLD 600UL 137 69 0.37 82 P2 TWD 19 VHN

+0.55 TEH TEC 17 COLD 600UL 137 71 0.45 48 P3 TWD 19 DBH

-1.64 TEH TEC 17 COLD 600UL 137 117 0.32 140 P3 TWD 16 DBH

+1.67 TEH TEC 16 COLD 600UL 0.40 115 P2 TWD 18 VHN

-0.82 TEN TEC 16 COLD 60OUL 138 58 0.44 69 P3 TWD 23 DBH

+1.87 TEH TEC 18 COLD 60OUL 138 64 0.27 101 P2 TWD 14 10H

+0.80 TEH TEC 18 COLD 600UL 138 80 0.40 70 P2 TWD 18 VHi

-0.86 TEH TEC 16 COLD 600UL 138 96 0.23 149 P3 TWD 12 DBC

+1.13 TEH TEC 16 COLD 600UL 138 102 0.44 97 P2 TWD 20 VHI

-0.86 TEH TEC 16 COLD 60OUL 139 61 0.24 104 P2 TWD 13 09C

-1.09 TEH TEC 18 COLD 600UL 139 65 0.31 95 P2 TWD 17 VH!

+0.88 TEH TEC 17 COLD 600UL 139 103 0.62 138 22 TWD 24 VH2

+0.84 TEH TEC 15 COLD 600UL

AREVA NP Inc 1/9/2008 2:18:17 PM Customer Name:

San Onofre -

Unit 2 Component: S/G 89 Page 15 of 16 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100%,

PCS QUERY: QueryMl[2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE

===========--

=== =--

-:===========================

- -----=======:==

= ------------

139 115 0.23 158 P3 TWD 12 DBH

+1.64 TEH TEC 16 COLD 60OUL 140 66 0.16 148 P3 TWD 8 DBH

+1.87 TEH TEC 17 COLD 60OUL 140 90 0.45 69 P2 TWD 20 VHl

-0.84 TEH TEC 16 COLD 60OUL 140 112 0.22 7

P3 TWD 12 DBC

+1.61 TEH TEC 16 COLD 60OUL 141 67 0.31 71 P2 TWD 16 09C

-1.07 TEH TEC 18 COLD 60OUL 141 83 0.24 136 P3 TWD 12 DBH

+1.80 TEH TEC 16 COLD 600UL 141 89 0.37 114 P2 TWD 18 VHl

-0.66 TEH TEC 16 COLD 600UL 141 103 0.23 31 P3 TWD 12 DBH

+2.02 TEH TEC 16 COLD 600UL 0.26 31 P2 TWD 13 VH3

-0.90 TEH TEC 16 COLD 600UL 0.26 83 P2 TWD 13 VH3

+0.88 TEH TEC 16 COLD 600UL 141 109 0.54 88 P2 TWD 22 VH3

+0.00 TEH TEC 15 COLD 60OUL 142 72 0.56 92 P3 TWD 27 DBC

+2.05 TEH TEC 18 COLD 600UL 142 92 0.51 106 P2 TWD 22 VHl

-0.88 TEH TEC 16 COLD 600UL 143 71 0.74 105 P2 TWD 29 VHl

-0.86 TEH TEC 18 COLD 60OUL 0.53 81 P2 TWD 24 VHl

+0.53 TEH TEC 18 COLD 600UL 0.45 126 P2 TWD 21 VHI

+0.86 TEH TEC 18 COLD 600UL 0.32 108 P2 TWD 16 VH2

-0.86 TEH TEC 18 COLD 600UL 0.57 108 P3 TWD 27 DOH

+2.17 TEH TEC 18 COLD 60OUL 143 75 0.30 151 P3 TWD 18 DBC

-1.68 TEH TEC 18 COLD 600UL 143 81 0.28 75 P2 TWD 14 VC1

-0.78 TEH TEC 16 COLD 600UL 143 85 0.24 99 P3 TWD 13 DBC

+1.32 TEH TEC 16 COLD 600UL 143 87 0.34 131 P2 TWD 15 10C

+0.88 TEH TEC 15 COLD 600UL 0.59 61 P3 TWD 21 DBC

+1.87 TEH TEC 15 COLD 600UL 0.26 53 P3 TWD 8 DBC

-1.99 TEH TEC 15 COLD 600UL 143 91 0.19 52 P3 TWD 11 DBH

+1.52 TEH TEC 16 COLD 600UL 143 105 0.22 166 P3 TWD 12 DBH

+1.81 TEH TEC 16 COLD 600UL 143 107 0.22 18 P3 TWD 12 DBH

-1.26 TEH TEC 16 COLD 60OUL 143 109 0.67 102 P3 TWD 27 DBC

-1.93 TEH TEC 16 COLD 600UL 144 78 0.25 148 P2 TWD 13 VC1

+0.82 TEH TEC 18 COLD 600UL 144 84 0.32 124 P3 TWD 13 DBC

-1.86 TEH TEC 15 COLD 60OUL 0.19 17 P3 TWD 8 DBC

+1.89 TEH TEC 15 COLD 60OUL 144 90 0.19 95 P2 TWD 10 VHI

-0.98 TEH TEC 16 COLD 600UL 144 102 0.26 71 P3 TWD 14 DBH

-1.64 TEH TEC 16 COLD 600UL 145 77 0.15 150 P3 TWD 10 DBH

-1.80 TEH TEC 18 COLD 60OUL 145 89 0.27 147 P3 TWD 14 DBH

+1.91 TEH TEC 16 COLD 600UL 0.44 84 P2 TWD 20 VC2

+0.90 TEH TEC 16 COLD 600UL 145 99 0.40 97 P3 TWD 19 DOH

+2.10 TEH TEC 16 COLD 60OUL 145 103 0.67 116 P3 TWD 27 DBH

+1.69 TEH TEC 16 COLD 600UL 146 76 0.28 78 P3 TWD 17 DBH

+2.17 TEH TEC 18 COLD 60OUL 146 78 0.50 96 P3 TWD 25 DBH

+1.84 TEE TEC 18 COLD 600UL 0.42 144 P3 TWD 23 DBC

+1.67 TEH TEC 18 COLD 60OUL 0.25 150 P3 TWD 15 DBC

-1.65 TEH TEC 18 COLD 600UL 146 80 0.26 145 P3 TWD 16 DBC

+1.62 TEH TEC 18 COLD 600UL 0.32 24 P3 TWD 19 DBH

+1.88 TEH TEC 18 COLD 600UL 146 88 0.51 55 P3 TWD 23 DBC

+1.64 TEH TEC 16 COLD 600UL Total Tubes

492 Total Records:

624

AREVA NP Inc Customer Name: San Onofre -

Unit 2 Post U2C15 Inspection Final Report

MAI, MCI,
MMI, MVIT, SAT,
SCI, SVI, 0-100%,

PCS QUERY: QueryMl(2].qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 1/9/2008 2:18:17 PM Component:

S/G 89 Page 16 of 16 EXT EXT CAL #

LEG PROBE