{{#Wiki_filter:.'-*
{{#Wiki_filter:.'-*
TECHNICAL SPECIFICATION CHANGE REQUEST - PROPOSED PAGES ,
TECHNICAL SPECIFICATION CHANGE REQUEST - PROPOSED PAGES,
Consumers Power Company Palisades Plant - Docket 50-255 RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS (RETS)
Consumers Power Company Palisades Plant - Docket 50-255 RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS (RETS)  
    ' 8410290206c 841025                     .
' 8410290206c 841025 PDR
PDR
* ADOCK
* ADOCK
* 05000255 * - ,
* 05000255 * -,  
  . *"p     *: *: ': *: * .. **, _~, .,PDR . . * . l 2 Pages OC1084-0007C-NL02
. *"p  
~,  
.,PDR  
.. *. l 2 Pages OC1084-0007C-NL02  


TABLE 3.24-2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM CHANNELS INSTRUMENT                     OPERABLE APPLICABILITY   ACTION
TABLE 3.24-2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM CHANNELS INSTRUMENT OPERABLE APPLICABILITY ACTION
: 1. WASTE GAS HOLDUP SYSTEM
: 1.
: a. Noble Gas Activity Monitor (RIA 1113)
WASTE GAS HOLDUP SYSTEM
Providing Alarm and Automatic Termi-nation of Release                         (1)    At All Times      35
: a.
: b. Effluent System Flow Rate Measuring Device (FI 1121)                 (1)    At All Times      36
Noble Gas Activity Monitor (RIA 1113)
: 2. CONDENSER EVACUATION SYSTEM (RIA 0631)
Providing Alarm and Automatic Termi-nation of Release
: a. Noble Gas Activity Monitor                 (1) . Above 210°F      37
: b.
: 3. STACK GAS EFFLUENT SYSTEM
Effluent System Flow Rate Measuring Device (FI 1121)
: a. Noble Gas Activity Monitor
: 2.
          . (RIA 2J26 or RIA 2318)                     (1)    At All Times      37
CONDENSER EVACUATION SYSTEM (RIA 0631)
: b. Iodine./Particulate/Sampler/Monitor       (1)    At All Times      37 (RIA 2325)
: a.
: c. Sampler Flow Rate Monitor                 (1)    At All Times      36
Noble Gas Activity Monitor
: d. Hi Range Noble Gas (RIA 2327)   **         (1)    Above 210°F      38
: 3.
: 4. STEAM GENERATOR BLOWDOWN VENT SYSTEM
STACK GAS EFFLUENT SYSTEM
: a. Noble Gas Activity Monitor CR.IA 2320)     (1)    Above 210°F      37
: a.
: 5. MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE
Noble Gas Activity Monitor  
: a. Gross Gamma Activity Monitor   **       1 per    Above 325°F      38 (RIA 2323 and 2324)                   Main Steam Line
. (RIA 2J26 or RIA 2318)
: 6. ENGINEERED SAFEGUARDS ROOM VENT SYSTEM
: b.
: a. Noble Gas Activity Monitor **         1 per     Above 210°F       38 (RIA 1810 and 1811)                    room
Iodine./Particulate/Sampler/Monitor (RIA 2325)
  ** Instruments exempted from Specification 3.24.5.1 setpoints.
: c.
Sampler Flow Rate Monitor
: d.
Hi Range Noble Gas (RIA 2327) **
: 4.
STEAM GENERATOR BLOWDOWN VENT SYSTEM
: a.
Noble Gas Activity Monitor CR.IA 2320)
: 5.
MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE
: a.
Gross Gamma Activity Monitor **
(RIA 2323 and 2324)
: 6.
ENGINEERED SAFEGUARDS ROOM VENT SYSTEM
: a.
Noble Gas Activity Monitor **
(RIA 1810 and 1811)
(1)
(1)
(1).
(1)
(1)
(1)
(1)
(1)
At All Times At All Times Above 210°F At All Times At All Times At All Times Above 210°F Above 210°F 1 per Above 325°F Main Steam Line 1 per room Above 210°F  
** Instruments exempted from Specification 3.24.5.1 setpoints.
Setpoints for these instruments are governed by Emergency Implementing Procedures, operating procedures or technical specifications.
Setpoints for these instruments are governed by Emergency Implementing Procedures, operating procedures or technical specifications.
3-118                         PROPOSED TS1084-0001-NL02
35 36 37 37 37 36 38 37 38 38 3-118 PROPOSED TS1084-0001-NL02  


3.24.6 GASEOUS WASTE TREATMENT SYSTEM LIMITING CONDITION FOR OPERATION 3.24.6.1 THE WASTE GAS DECAY TANK SYSTEM shall be used to reduce radioactive gaseous effluents by holding gaseous waste collected by the system for a mini-mum of 15 days up to 60 days.
3.24.6 GASEOUS WASTE TREATMENT SYSTEM LIMITING CONDITION FOR OPERATION 3.24.6.1 THE WASTE GAS DECAY TANK SYSTEM shall be used to reduce radioactive gaseous effluents by holding gaseous waste collected by the system for a mini-mum of 15 days up to 60 days.
APPLICABILITY:   When gaseous waste exceeds a Xe-133 concentration of lE-05
APPLICABILITY:
    µCi/cc.
When gaseous waste exceeds a Xe-133 concentration of lE-05  
µCi/cc.
ACTION:
ACTION:
: a. If.a waste gas decay tank is required to be released with less than 60 days holdup time, the system waste gas tank contents shall be evaluated and the waste gas decay tank with the lowest Xe-133 content shall be released.
: a.
: b. Gaseous waste may be discharged directly from the waste gas surge tank through a high-efficiency filter or from a waste gas decay tank with less than 15 days of holdup directly to the stack for a period not to exceed 7 days if the holdup system equipment is not available and the release rates meet Specification 3.24.5.
If.a waste gas decay tank is required to be released with less than 60 days holdup time, the system waste gas tank contents shall be evaluated and the waste gas decay tank with the lowest Xe-133 content shall be released.
: c. Theyrovisions of Specifications 3.0.3 and 3.0.4 are not applicable.
: b.
Gaseous waste may be discharged directly from the waste gas surge tank through a high-efficiency filter or from a waste gas decay tank with less than 15 days of holdup directly to the stack for a period not to exceed 7 days if the holdup system equipment is not available and the release rates meet Specification 3.24.5.
: c.
Theyrovisions of Specifications 3.0.3 and 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS Not applicable.
SURVEILLANCE REQUIREMENTS Not applicable.
3-125                         PROPOSED TS1084-0002-NL02}}
3-125 PROPOSED TS1084-0002-NL02}}

Latest revision as of 09:51, 6 January 2025

Proposed Radiological Effluent Tech Spec Changes,Adding Footnote to Table 3.24-2 to Exempt Three Instrument Setpoints from Spec 3.24.5.1
ML18051B096
Person / Time
Site: Palisades 
Issue date: 10/25/1984
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML18051B095 List:
References
NUDOCS 8410290206
Download: ML18051B096 (3)


Text

.'-*

TECHNICAL SPECIFICATION CHANGE REQUEST - PROPOSED PAGES,

Consumers Power Company Palisades Plant - Docket 50-255 RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS (RETS)

' 8410290206c 841025 PDR

  • ADOCK
  • 05000255 * -,

. *"p

~,

.,PDR

.. *. l 2 Pages OC1084-0007C-NL02

TABLE 3.24-2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM CHANNELS INSTRUMENT OPERABLE APPLICABILITY ACTION

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor (RIA 1113)

Providing Alarm and Automatic Termi-nation of Release

b.

Effluent System Flow Rate Measuring Device (FI 1121)

2.

CONDENSER EVACUATION SYSTEM (RIA 0631)

a.

Noble Gas Activity Monitor

3.

STACK GAS EFFLUENT SYSTEM

a.

Noble Gas Activity Monitor

. (RIA 2J26 or RIA 2318)

b.

Iodine./Particulate/Sampler/Monitor (RIA 2325)

c.

Sampler Flow Rate Monitor

d.

Hi Range Noble Gas (RIA 2327) **

4.

STEAM GENERATOR BLOWDOWN VENT SYSTEM

a.

Noble Gas Activity Monitor CR.IA 2320)

5.

MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE

a.

Gross Gamma Activity Monitor **

(RIA 2323 and 2324)

6.

ENGINEERED SAFEGUARDS ROOM VENT SYSTEM

a.

Noble Gas Activity Monitor **

(RIA 1810 and 1811)

(1)

(1)

(1).

(1)

(1)

(1)

(1)

(1)

At All Times At All Times Above 210°F At All Times At All Times At All Times Above 210°F Above 210°F 1 per Above 325°F Main Steam Line 1 per room Above 210°F

    • Instruments exempted from Specification 3.24.5.1 setpoints.

Setpoints for these instruments are governed by Emergency Implementing Procedures, operating procedures or technical specifications.

35 36 37 37 37 36 38 37 38 38 3-118 PROPOSED TS1084-0001-NL02

3.24.6 GASEOUS WASTE TREATMENT SYSTEM LIMITING CONDITION FOR OPERATION 3.24.6.1 THE WASTE GAS DECAY TANK SYSTEM shall be used to reduce radioactive gaseous effluents by holding gaseous waste collected by the system for a mini-mum of 15 days up to 60 days.

APPLICABILITY:

When gaseous waste exceeds a Xe-133 concentration of lE-05

µCi/cc.

ACTION:

a.

If.a waste gas decay tank is required to be released with less than 60 days holdup time, the system waste gas tank contents shall be evaluated and the waste gas decay tank with the lowest Xe-133 content shall be released.

b.

Gaseous waste may be discharged directly from the waste gas surge tank through a high-efficiency filter or from a waste gas decay tank with less than 15 days of holdup directly to the stack for a period not to exceed 7 days if the holdup system equipment is not available and the release rates meet Specification 3.24.5.

c.

Theyrovisions of Specifications 3.0.3 and 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS Not applicable.

3-125 PROPOSED TS1084-0002-NL02