TECHNICAL SPECIFICATION CHANGE REQUEST - PROPOSED PAGES,
Consumers Power Company Palisades Plant - Docket 50-255 RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS (RETS)
' 8410290206c 841025 PDR
- ADOCK
- 05000255 * -,
. *"p
~,
.,PDR
.. *. l 2 Pages OC1084-0007C-NL02
TABLE 3.24-2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM CHANNELS INSTRUMENT OPERABLE APPLICABILITY ACTION
- 1.
WASTE GAS HOLDUP SYSTEM
- a.
Noble Gas Activity Monitor (RIA 1113)
Providing Alarm and Automatic Termi-nation of Release
- b.
Effluent System Flow Rate Measuring Device (FI 1121)
- 2.
CONDENSER EVACUATION SYSTEM (RIA 0631)
- a.
Noble Gas Activity Monitor
- 3.
STACK GAS EFFLUENT SYSTEM
- a.
Noble Gas Activity Monitor
. (RIA 2J26 or RIA 2318)
- b.
Iodine./Particulate/Sampler/Monitor (RIA 2325)
- c.
Sampler Flow Rate Monitor
- d.
Hi Range Noble Gas (RIA 2327) **
- 4.
STEAM GENERATOR BLOWDOWN VENT SYSTEM
- a.
Noble Gas Activity Monitor CR.IA 2320)
- 5.
MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE
- a.
Gross Gamma Activity Monitor **
(RIA 2323 and 2324)
- 6.
ENGINEERED SAFEGUARDS ROOM VENT SYSTEM
- a.
Noble Gas Activity Monitor **
(RIA 1810 and 1811)
(1)
(1)
(1).
(1)
(1)
(1)
(1)
(1)
At All Times At All Times Above 210°F At All Times At All Times At All Times Above 210°F Above 210°F 1 per Above 325°F Main Steam Line 1 per room Above 210°F
- Instruments exempted from Specification 3.24.5.1 setpoints.
Setpoints for these instruments are governed by Emergency Implementing Procedures, operating procedures or technical specifications.
35 36 37 37 37 36 38 37 38 38 3-118 PROPOSED TS1084-0001-NL02
3.24.6 GASEOUS WASTE TREATMENT SYSTEM LIMITING CONDITION FOR OPERATION 3.24.6.1 THE WASTE GAS DECAY TANK SYSTEM shall be used to reduce radioactive gaseous effluents by holding gaseous waste collected by the system for a mini-mum of 15 days up to 60 days.
APPLICABILITY:
When gaseous waste exceeds a Xe-133 concentration of lE-05
µCi/cc.
ACTION:
- a.
If.a waste gas decay tank is required to be released with less than 60 days holdup time, the system waste gas tank contents shall be evaluated and the waste gas decay tank with the lowest Xe-133 content shall be released.
- b.
Gaseous waste may be discharged directly from the waste gas surge tank through a high-efficiency filter or from a waste gas decay tank with less than 15 days of holdup directly to the stack for a period not to exceed 7 days if the holdup system equipment is not available and the release rates meet Specification 3.24.5.
- c.
Theyrovisions of Specifications 3.0.3 and 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS Not applicable.
3-125 PROPOSED TS1084-0002-NL02