Line 16: Line 16:
| event date = 10/16/2003 15:30 EDT
| event date = 10/16/2003 15:30 EDT
| last update date = 10/16/2003
| last update date = 10/16/2003
| title = 24 Hour Bulletin 91-01 Notification From Westinghouse Columbia Fuel Facility
| title = 24 Hour Bulletin 91-01 Notification from Westinghouse Columbia Fuel Facility
| event text = Double Contingency Protection: Double contingency protection for the ADU Bulk Blending System is assured by (1) preventing moderator from becoming available to a bulk container, and (2) preventing moderator from entering a bulk container. The first contingency did not occur because the moderator was never available to a bulk container. Moderator is prevented from entering a bulk container by preventing high moisture polypaks from being dumped into the bulk container. The polypaks are processed through a scan and dump interlock, which prevents unacceptable polypaks from being dumped. The software malfunction left less than previously documented double contingency protection for the system. In accordance with Westinghouse Operating License (SNM-1107), paragraph 3.7.3 (c.5a), this event satisfies the criteria for a 24-hour notification.
| event text = Double Contingency Protection: Double contingency protection for the ADU Bulk Blending System is assured by (1) preventing moderator from becoming available to a bulk container, and (2) preventing moderator from entering a bulk container. The first contingency did not occur because the moderator was never available to a bulk container. Moderator is prevented from entering a bulk container by preventing high moisture polypaks from being dumped into the bulk container. The polypaks are processed through a scan and dump interlock, which prevents unacceptable polypaks from being dumped. The software malfunction left less than previously documented double contingency protection for the system. In accordance with Westinghouse Operating License (SNM-1107), paragraph 3.7.3 (c.5a), this event satisfies the criteria for a 24-hour notification.
As Found Condition: See Reason for Notification above.
As Found Condition: See Reason for Notification above.

Revision as of 22:24, 1 March 2018

ENS 40255 +/-
Where
Westinghouse Electric Corporation
Columbia, South Carolina (NRC Region 2)
License number: Snm-1107
Reporting
Response
Time - Person (Reporting Time:+-1.62 h-0.0675 days <br />-0.00964 weeks <br />-0.00222 months <br />)
Opened: David Williams
17:53 Oct 16, 2003
NRC Officer: Rich Laura
Last Updated: Oct 16, 2003
40255 - NRC Website