| event date = 11/17/2003 09:00 CST
| event date = 11/17/2003 09:00 CST
| last update date = 11/17/2003
| last update date = 11/17/2003
| title = Reactor Coolant System Leakage Due To A Cracked Socket Weld
| title = Reactor Coolant System Leakage Due to a Cracked Socket Weld
| event text = During routine operations activities a leak was identified in the area of EPV0109 (combined SI/RHR to Accumulator "D" outlet line vent).  At 0900 it was determined that the leak was due to a cracked weld on the socket up stream of EPV0109. The leak rate is 25-30 drops/per minute
| event text = During routine operations activities a leak was identified in the area of EPV0109 (combined SI/RHR to Accumulator "D" outlet line vent).  At 0900 it was determined that the leak was due to a cracked weld on the socket up stream of EPV0109. The leak rate is 25-30 drops/per minute
.
.

Latest revision as of 21:24, 1 March 2018

ENS 40327 +/-
Where
Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Kansas (NRC Region 4)
Reporting
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded
Time - Person (Reporting Time:+1.13 h0.0471 days <br />0.00673 weeks <br />0.00155 months <br />)
Opened: David Dees
16:08 Nov 17, 2003
NRC Officer: Chauncey Gould
Last Updated: Nov 17, 2003
40327 - NRC Website