| Title | Reactor Coolant System Leakage Due to a Cracked Socket Weld |
| Event Description | During routine operations activities a leak was identified in the area of EPV0109 (combined SI/RHR to Accumulator "D" outlet line vent). At 0900 it was determined that the leak was due to a cracked weld on the socket up stream of EPV0109. The leak rate is 25-30 drops/per minute
. This condition is being reported as a degraded condition in the primary coolant system under 10CFR50.72(b)(3)(ii)(A). The plant is currently in Mode 5 with RCS pressure at approximately 345 psig and temperature at approximately 125F. Shutdown cooling is being supplied by the "A" train Residual Heat Removal System. The Resident Inspector has been notified. |
| Where | |
|---|---|
| Wolf Creek Kansas (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| Time - Person (Reporting Time:+1.13 h0.0471 days <br />0.00673 weeks <br />0.00155 months <br />) | |
| Opened: | David Dees 16:08 Nov 17, 2003 |
| NRC Officer: | Chauncey Gould |
| Last Updated: | Nov 17, 2003 |
| 40327 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 40327\u003C/a\u003E - \u003Ca href=\"/Wolf_Creek\" title=\"Wolf Creek\"\u003EWolf Creek\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EReactor Coolant System Leakage Due to a Cracked Socket Weld\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 40327 - Wolf Creek\n","link":"","lat":38.239158333333336,"lon":-95.68945833333333,"icon":"/w/images/4/42/Wolf_Creek_Nuclear_Operating_Corporation_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Cold Shutdown (0 %) |
| After | Cold Shutdown (0 %) |
WEEKMONTHYEARENS 500472014-04-20T19:42:00020 April 2014 19:42:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Emergency Core Cooling System Piping Leak While Shutdown ENS 487132013-02-04T19:40:0004 February 2013 19:40:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Coolant System Pressure Boundary Leakage Identified on Seal Injection Line Drain Valve ENS 428972006-10-11T17:40:00011 October 2006 17:40:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Unanalyzed Condition - Indications on Pressurizer Nozzle to Safe End Welds ENS 416022005-04-15T10:17:00015 April 2005 10:17:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Steam Generator Bowl Drain Line Weld Leak Discovered During Visual Exam ENS 403272003-11-17T15:00:00017 November 2003 15:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Coolant System Leakage Due to a Cracked Socket Weld 2014-04-20T19:42:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_40327&oldid=428864"