| title = Both Divisions Of Primary Containment Oxygen And Hydrogen Atmospheric Monitors Inoperable For Maintenance
| title = Both Divisions of Primary Containment Oxygen and Hydrogen Atmospheric Monitors Inoperable for Maintenance
| event text = This notification is being made due to a loss of emergency assessment capability in accordance with 10 CFR 50.72(b)(3)(xiii).  At 0838 PST on 12/19/2013, the Division 1 sample rack for monitoring primary containment oxygen and hydrogen atmospheric concentrations was removed from service for planned maintenance activities.  The Division 1 sample rack is expected to be out of service for 14 hours.  The redundant Division 2 sample rack was previously removed from service for maintenance and remains out of service for repairs.  Compensatory measures to monitor primary containment for hydrogen and oxygen are available via grab samples using chemistry procedures.
| event text = This notification is being made due to a loss of emergency assessment capability in accordance with 10 CFR 50.72(b)(3)(xiii).  At 0838 PST on 12/19/2013, the Division 1 sample rack for monitoring primary containment oxygen and hydrogen atmospheric concentrations was removed from service for planned maintenance activities.  The Division 1 sample rack is expected to be out of service for 14 hours.  The redundant Division 2 sample rack was previously removed from service for maintenance and remains out of service for repairs.  Compensatory measures to monitor primary containment for hydrogen and oxygen are available via grab samples using chemistry procedures.
The NRC Resident Inspector has been notified.
The NRC Resident Inspector has been notified.

Latest revision as of 20:52, 1 March 2018

ENS 49661 +/-
Where
Columbia Generating Station Energy Northwest icon.png
Washington (NRC Region 4)
Reporting
10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness
Time - Person (Reporting Time:+-3.67 h-0.153 days <br />-0.0218 weeks <br />-0.00503 months <br />)
Opened: Greg Knudson
12:58 Dec 19, 2013
NRC Officer: Donald Norwood
Last Updated: Dec 20, 2013
49661 - NRC Website
Loading map...