ENS 50380
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
14:33 Aug 19, 2014 | |
| Title | Loss of Assessment Capability |
| Event Description | This notification is being made due to a loss of emergency assessment capability in accordance with 10 CFR 50.72(b)(3)(xiii). At 0733 (PDT), on 08/19/2014, PRM-RE-18, Reactor Building Stack Monitor - Intermediate Range Detector, failed downscale. PRM-RE-1A and PRM-RE-1C, the Reactor Building Stack Monitor - low and high range detectors, both remain operable and fully functional. Compensatory measures are being implemented per plant procedures at this time.
The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Columbia Washington (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+-0.32 h-0.0133 days <br />-0.0019 weeks <br />-4.38336e-4 months <br />) | |
| Opened: | Nicholas Rullman 14:14 Aug 19, 2014 |
| NRC Officer: | Daniel Mills |
| Last Updated: | Aug 19, 2014 |
| 50380 - NRC Website
Loading map... | |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (47 %) |
| After | Power Operation (47 %) |
WEEKMONTHYEARENS 571632024-06-05T04:41:0005 June 2024 04:41:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Primary Containment Isolation Due to Loss of Rps Power Supply ENS 544662020-01-08T02:55:0008 January 2020 02:55:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Seismic Assessment Instrumentation ENS 544092019-11-25T16:54:00025 November 2019 16:54:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness En Revision Imported Date 11/28/2019 ENS 537752018-12-04T08:00:0004 December 2018 08:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Assessment Capability ENS 517332016-02-13T18:00:00013 February 2016 18:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radwaste Building Noble Gas Monitor Out-Of-Service ENS 510942015-05-28T05:17:00028 May 2015 05:17:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Area Radiation Monitors Non-Functional During Planned Bus Outage ENS 510272015-04-30T01:11:00030 April 2015 01:11:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Rod Position Indicator System (Rpis) Unplanned Outage ENS 510682015-04-03T07:00:0003 April 2015 07:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Radiological Assessment Capability Due to Non-Functional Radiation Monitor ENS 505692014-10-23T17:46:00023 October 2014 17:46:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Turbine Building Exhaust Sample Rack Declared Non-Functional ENS 503802014-08-19T14:33:00019 August 2014 14:33:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Assessment Capability ENS 503412014-08-05T00:01:0005 August 2014 00:01:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radwaste Building Radiation Monitoring Sample Rack Declared Nonfunctional ENS 502942014-07-22T13:35:00022 July 2014 13:35:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radiation Monitoring Sample Rack Declared Non-Functional ENS 502592014-07-04T09:33:0004 July 2014 09:33:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Turbine Building Process Radiation Monitoring Non-Functional ENS 501822014-06-09T14:15:0009 June 2014 14:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radiation Monitoring Sample Rack Declared Non-Functional ENS 500842014-05-03T02:20:0003 May 2014 02:20:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Reactor Building Stack Radiation Monitor Failure ENS 498412014-02-19T16:29:00019 February 2014 16:29:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Primary Containment Oxygen and Hydrogen Monitoring ENS 497652014-01-27T08:45:00027 January 2014 08:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Turbine and Rad Waste Buildings Radiation Monitors Inoperable Due to Planned Maintenance ENS 497022014-01-08T18:10:0008 January 2014 18:10:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Assessment Capability - Non-Functional Area Radiation Monitors ENS 497002014-01-07T20:10:0007 January 2014 20:10:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Reactor Building Stack Monitor Temporarily Out of Service for Maintenance ENS 496612013-12-19T16:38:00019 December 2013 16:38:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Both Divisions of Primary Containment Oxygen and Hydrogen Atmospheric Monitors Inoperable for Maintenance ENS 496452013-12-17T19:33:00017 December 2013 19:33:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Reactor Building Stack Radiation Monitor Inoperable Due to Scheduled Maintenance on Supporting Equipment ENS 496262013-12-12T12:36:00012 December 2013 12:36:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Both Trains of Primary Containment Hydrogen and Oxygen Monitors Out of Service for Maintenance ENS 496032013-12-03T16:22:0003 December 2013 16:22:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Reactor Building Stack Radiation Monitor Non-Functional Due to Scheduled Maintenance ENS 495452013-11-17T17:55:00017 November 2013 17:55:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Drywell Sampling Capability ENS 494732013-10-24T17:35:00024 October 2013 17:35:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Failure of Radwaste Building Effluent Radiation Monitor ENS 493322013-09-09T11:07:0009 September 2013 11:07:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Maintenance on Technical Support Center / Operations Support Center Ventilation ENS 493282013-09-06T13:07:0006 September 2013 13:07:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radiation Monitoring Sample Rack Declared Non-Functional ENS 493272013-09-06T05:44:0006 September 2013 05:44:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Turbine Building Stack Radiation Monitor Out of Service ENS 493062013-08-24T23:14:00024 August 2013 23:14:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Malfunction of Stack Radiation Monitor Supporting Equipment ENS 492902013-08-19T17:13:00019 August 2013 17:13:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Increasing Background Noise in Stack Radiation Monitor Renders It Non-Functional ENS 491932013-07-16T11:30:00016 July 2013 11:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Maintenance on Technical Support Center / Operations Support Center Ventilation ENS 490522013-05-19T21:21:00019 May 2013 21:21:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Outage of Radiological and Seismic Monitoring Capability ENS 490312013-05-14T22:02:00014 May 2013 22:02:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Power Outage at Tsc and Osc ENS 489122013-04-10T16:52:00010 April 2013 16:52:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Reactor Building Stack Access Door Not Fully Closed ENS 481702012-08-08T20:50:0008 August 2012 20:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Assessment Capability ENS 481012012-07-12T20:15:00012 July 2012 20:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Power Supply Problems to Various Area Rad Monitors ENS 479212012-05-14T10:00:00014 May 2012 10:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out-Of-Service Due to Planned Maintenance ENS 476812012-02-21T08:55:00021 February 2012 08:55:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Data Processing Network Failure Impacted Emergency Response Data System ENS 474292011-11-10T22:39:00010 November 2011 22:39:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Technical Support Center Emergency Filtration System During Maintenance ENS 474412011-11-05T20:30:0005 November 2011 20:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Major Loss of Emergency Preparedness Capability Due to Network Isolation Device Failure ENS 473432011-10-11T16:50:00011 October 2011 16:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System Inoperable ENS 480052011-09-17T19:00:00017 September 2011 19:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Major Loss of Emergency Assessment Capability Due to Degraded Dose Projection ENS 456712010-02-02T03:13:0002 February 2010 03:13:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Tsc Unavailable for Planned Hvac Maintenance ENS 454872009-11-10T08:00:00010 November 2009 08:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Tsc Due to Planned Mantenance ENS 451112009-06-01T23:50:0001 June 2009 23:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Tsc Air Conditioning Unit Compressor ENS 417372005-05-31T17:00:00031 May 2005 17:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss and Subsequent Restoration of Emergency Response Data System (Erds) 2024-06-05T04:41:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_50380&oldid=422063"