ENS 50792: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 02/06/2015 12:27 CST
| event date = 02/06/2015 12:27 CST
| last update date = 02/06/2015
| last update date = 02/06/2015
| title = Automatic Reactor Scram Due To Loss Of Feedwater
| title = Automatic Reactor Scram Due to Loss of Feedwater
| event text = At 1227 CST on 06 Feb 2015, Dresden Unit 2 automatically scrammed due to a Reactor Water Level transient.  Set up activities for weekend maintenance were being performed on the feedwater system at the time of the event.
| event text = At 1227 CST on 06 Feb 2015, Dresden Unit 2 automatically scrammed due to a Reactor Water Level transient.  Set up activities for weekend maintenance were being performed on the feedwater system at the time of the event.
All rods inserted to their full-in positions.
All rods inserted to their full-in positions.

Latest revision as of 20:48, 1 March 2018

ENS 50792 +/-
Where
Dresden Constellation icon.png
Illinois (NRC Region 3)
Reporting
10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge

10 CFR 50.72(b)(2)(iv)(B), RPS Actuation

10 CFR 50.72(b)(3)(iv)(A), System Actuation
Time - Person (Reporting Time:+-1.57 h-0.0654 days <br />-0.00935 weeks <br />-0.00215 months <br />)
Opened: Ryan Sears
16:53 Feb 6, 2015
NRC Officer: Daniel Mills
Last Updated: Feb 6, 2015
50792 - NRC Website
Loading map...