{{#Wiki_filter:4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office 10 CFR 50.90 RS-22- | {{#Wiki_filter:4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office | ||
10 CFR 50.90 | |||
RS-22-0 73 | |||
May 19, 2022 | |||
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 | |||
Braidwood Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. 50-456 and 50-457 | |||
Byron Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. 50-454 and 50-455 | |||
==Subject:== | ==Subject:== | ||
Supplemental Information regarding | Supplemental Information regarding L icense Amendment Request - Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-5 01, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control " | ||
==Reference:== | ==Reference:== | ||
Letter from K. Lueshen (Constellation Energy Generation, LLC) to Nuclear Regulatory Commission (NRC), "License Amendment Request - Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control," dated April 21, 2022 (ML22111A300) | |||
In the referenced letter, Constellation Energy Generation, LLC (CEG) submitted its application to adopt Technical Specification Task Force (TSTF) Travel er 501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control " for Braidwood and Byron stations. | |||
During the acceptance review period, an editorial correction was identified with the submitted Technical Specification pages contained in the application. This letter supplements the identified pages with the editorial corrections addressed. | During the acceptance review period, an editorial correction was identified with the submitted Technical Specification pages contained in the application. This letter supplements the identified pages with the editorial corrections addressed. | ||
There are no regulatory commitments contained in this request. | There are no regulatory commitments contained in this request. | ||
This letter does not affect CEG's conclusion that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92. | This letter does not affect CEG's conclusion that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92. | ||
U.S. Nuclear Regulatory Commission May 19, 2022 Page 2 | |||
In accordance with 10 CFR 50.91, "Notice for public comment; State consultation," paragraph (b), CEG is transmitting a copy of this application and its attachments to the designated State of Illinois official. | |||
Should you have any questions concerning this submittal, please contact Jason Taken at (630) 657-3660. | Should you have any questions concerning this submittal, please contact Jason Taken at (630) 657-3660. | ||
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 19th May, 2022. | I declare under penalty of perjury that the foregoing is true and correct. Executed on the 19th May, 2022. | ||
U.S. Nuclear Regulatory Commission May 19, 2022 Page 3 Attachments: | Respectfully, | ||
Kevin Lueshen Senior Manager - Licensing Constellation Energy Generation, LLC | |||
U.S. Nuclear Regulatory Commission May 19, 2022 Page 3 | |||
Attachments: | |||
: 1. Proposed Technical Specification Mark-ups (Braidwood) | : 1. Proposed Technical Specification Mark-ups (Braidwood) | ||
: 2. Proposed Technical Specification Mark-ups (Byron) cc: | : 2. Proposed Technical Specification Mark-ups (Byron) | ||
cc: NRC Region III, Regional Administrator NRC Senior Resident Inspector, BWD,BYR NRC Project Manager, BWD,BYR Illinois Emergency Management Agency, Illinois Division of Reactor Safety | |||
ATTACHMENT 1 | |||
Proposed Technical Specification Marked-Up Pages | |||
Braidwood Station | |||
Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control" | |||
TS Pages 3.8.3-1 Diesel Fuel Oil 3.8.3 | |||
3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil | |||
LCO 3.8.3 The stored diesel fuel oil shall be within limits for each required Diesel Generator (DG). | |||
APPLICABILITY: When associated DG is required to be OPERABLE. | |||
ACTIONS | ACTIONS | ||
-------------------------------------NOTE------------------------------------- | -------------------------------------NOTE------------------------------------- | ||
Separate Condition entry is allowed for each DG. | Separate Condition entry is allowed for each DG. | ||
CONDITION | |||
CONDITION REQUIRED ACTION COMPLETION TIME | |||
A. One or more DGs with stored fuel volume A.1 Restore stored fuel oil volume to within 48 hours | |||
< 44,000 galless than limits. | |||
a 7 day supply and | a 7 day supply and | ||
> 41,138 galgreater than a 6 day supply in storage tank(s). | |||
B. One or more DGs with | |||
B. One or more DGs with B.1 Restore fuel oil 7 days stored fuel oil total total particulates particulates not within limit. | |||
within limit. | within limit. | ||
C. One or more DGs with | |||
C. One or more DGs with C.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits. | |||
limits. | limits. | ||
(continued) | (continued) | ||
ATTACHMENT 2 Proposed Technical Specification Marked-Up Pages Byron Station Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control" TS Pages 3.8.3-1 | BRAIDWOOD UNITS 1 & 2 3.8.3 1 Amendment 98 ATTACHMENT 2 | ||
Proposed Technical Specification Marked-Up Pages | |||
Byron Station | |||
Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control" | |||
TS Pages 3.8.3-1 Diesel Fuel Oil 3.8.3 | |||
3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil | |||
LCO 3.8.3 The stored diesel fuel oil shall be within limits for each required Diesel Generator (DG). | |||
APPLICABILITY: When associated DG is required to be OPERABLE. | |||
ACTIONS | ACTIONS | ||
-------------------------------------NOTE------------------------------------- | -------------------------------------NOTE------------------------------------- | ||
Separate Condition entry is allowed for each DG. | Separate Condition entry is allowed for each DG. | ||
CONDITION | |||
CONDITION REQUIRED ACTION COMPLETION TIME | |||
A. One or more DGs with stored fuel volume A.1 Restore stored fuel oil volume to within 48 hours | |||
< 44,000 galless than limits. | |||
a 7 day supply and | a 7 day supply and | ||
> 41,138 galgreater than a 6 day supply in storage tank(s). | |||
B. One or more DGs with | |||
B. One or more DGs with B.1 Restore fuel oil 7 days stored fuel oil total total particulates particulates not within limit. | |||
within limit. | within limit. | ||
C. One or more DGs with | |||
C. One or more DGs with C.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits. | |||
limits. | limits. | ||
(continued) | (continued) | ||
BYRON | |||
BYRON UNITS 1 & 2 3.8.3 1 Amendment 106}} | |||
Revision as of 01:13, 18 November 2024
| ML22139A152 | |
| Person / Time | |
|---|---|
| Site: | Byron, Braidwood |
| Issue date: | 05/19/2022 |
| From: | Lueshen K Constellation Energy Generation |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| RS-22-073 | |
| Download: ML22139A152 (7) | |
Text
4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office
RS-22-0 73
May 19, 2022
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Braidwood Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. 50-456 and 50-457
Byron Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. 50-454 and 50-455
Subject:
Supplemental Information regarding L icense Amendment Request - Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-5 01, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control "
Reference:
Letter from K. Lueshen (Constellation Energy Generation, LLC) to Nuclear Regulatory Commission (NRC), "License Amendment Request - Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control," dated April 21, 2022 (ML22111A300)
In the referenced letter, Constellation Energy Generation, LLC (CEG) submitted its application to adopt Technical Specification Task Force (TSTF) Travel er 501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control " for Braidwood and Byron stations.
During the acceptance review period, an editorial correction was identified with the submitted Technical Specification pages contained in the application. This letter supplements the identified pages with the editorial corrections addressed.
There are no regulatory commitments contained in this request.
This letter does not affect CEG's conclusion that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92.
U.S. Nuclear Regulatory Commission May 19, 2022 Page 2
In accordance with 10 CFR 50.91, "Notice for public comment; State consultation," paragraph (b), CEG is transmitting a copy of this application and its attachments to the designated State of Illinois official.
Should you have any questions concerning this submittal, please contact Jason Taken at (630) 657-3660.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 19th May, 2022.
Respectfully,
Kevin Lueshen Senior Manager - Licensing Constellation Energy Generation, LLC
U.S. Nuclear Regulatory Commission May 19, 2022 Page 3
Attachments:
- 1. Proposed Technical Specification Mark-ups (Braidwood)
- 2. Proposed Technical Specification Mark-ups (Byron)
cc: NRC Region III, Regional Administrator NRC Senior Resident Inspector, BWD,BYR NRC Project Manager, BWD,BYR Illinois Emergency Management Agency, Illinois Division of Reactor Safety
ATTACHMENT 1
Proposed Technical Specification Marked-Up Pages
Braidwood Station
Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control"
TS Pages 3.8.3-1 Diesel Fuel Oil 3.8.3
3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil
LCO 3.8.3 The stored diesel fuel oil shall be within limits for each required Diesel Generator (DG).
APPLICABILITY: When associated DG is required to be OPERABLE.
ACTIONS
NOTE-------------------------------------
Separate Condition entry is allowed for each DG.
CONDITION REQUIRED ACTION COMPLETION TIME
A. One or more DGs with stored fuel volume A.1 Restore stored fuel oil volume to within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />
< 44,000 galless than limits.
a 7 day supply and
> 41,138 galgreater than a 6 day supply in storage tank(s).
B. One or more DGs with B.1 Restore fuel oil 7 days stored fuel oil total total particulates particulates not within limit.
within limit.
C. One or more DGs with C.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits.
limits.
(continued)
BRAIDWOOD UNITS 1 & 2 3.8.3 1 Amendment 98 ATTACHMENT 2
Proposed Technical Specification Marked-Up Pages
Byron Station
Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-501, Revision 1, "Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control"
TS Pages 3.8.3-1 Diesel Fuel Oil 3.8.3
3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil
LCO 3.8.3 The stored diesel fuel oil shall be within limits for each required Diesel Generator (DG).
APPLICABILITY: When associated DG is required to be OPERABLE.
ACTIONS
NOTE-------------------------------------
Separate Condition entry is allowed for each DG.
CONDITION REQUIRED ACTION COMPLETION TIME
A. One or more DGs with stored fuel volume A.1 Restore stored fuel oil volume to within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />
< 44,000 galless than limits.
a 7 day supply and
> 41,138 galgreater than a 6 day supply in storage tank(s).
B. One or more DGs with B.1 Restore fuel oil 7 days stored fuel oil total total particulates particulates not within limit.
within limit.
C. One or more DGs with C.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits.
limits.
(continued)
BYRON UNITS 1 & 2 3.8.3 1 Amendment 106