ENS 55785: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 12: Line 12:
| emergency class = Non Emergency
| emergency class = Non Emergency
| notification date = 03/12/2022 06:56
| notification date = 03/12/2022 06:56
| retracted = Yes
| notification by = James Jackson
| notification by = James Jackson
| NRC officer = Lloyd Desotell
| NRC officer = Lloyd Desotell
| event date = 03/12/2022 00:50 EST
| event date = 03/12/2022 00:50 EST
| last update date = 03/12/2022
| last update date = 04/26/2022
| title = Main Steam Isolation Valve Failed to Shut
| title = Main Steam Isolation Valve Failed to Shut
| event text = The following information was provided by the licensee via email:
| event text = The following information was provided by the licensee via email:
Line 21: Line 22:
This condition is being reported pursuant to 10 CFR 50.72(b)(3)(v).
This condition is being reported pursuant to 10 CFR 50.72(b)(3)(v).
The NRC Resident Inspector has been notified.
The NRC Resident Inspector has been notified.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/20220314en.html#en55785
* * * RETRACTION ON 04/26/22 AT 1422 EDT FROM DAVID STOIA TO BRIAN PARKS * * *
The following information was provided by the licensee via email:
On 3/12/2022 at 0656 EDT Turkey Point Unit 4 notified the NRC pursuant to 10 CFR 50.72(b)(3)(v)(D) that a single Main Steam Isolation Valve (MSIV) did not fully close when manually demanded from the control room during shutdown of Unit 4 for a refueling outage. Following disassembly and inspection of the MSIV, Florida Power & Light Engineering identified the cause of the deficiency and determined that the valve would have fully seated under its design accident conditions.
This notification is a retraction of EN# 55785. The NRC Resident Inspector has been notified of this retraction.
Notified R2DO (Miller).
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/20220427en.html#en55785
}}{{unit info
}}{{unit info
| Unit = 4
| Unit = 4
| type = W-3-LP
| type = W-3-LP
| Scram code = N
| Scram code = N
| Reactor critical = Y
| Reactor critical = N
| Initial power = 0
| Initial power = 0
| Initial reactor mode = Hot Standby
| Initial reactor mode = Hot Standby

Latest revision as of 07:30, 27 April 2022

ENS 55785 +/- *RETRACTED*
Where
Turkey Point NextEra Energy icon.png
Florida (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+1.1 h0.0458 days <br />0.00655 weeks <br />0.00151 months <br />)
Opened: James Jackson
06:56 Mar 12, 2022
NRC Officer: Lloyd Desotell
Last Updated: Apr 26, 2022
55785 - NRC Website
Loading map...