| description = The inspectors identified a Green finding and an associated Non-Cited Violation (NCV)of Title 10 of the Code of Federal Regulations (CFR),Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the failure to prescribe motor driven auxiliary feedwater pump test procedures that accounted for the allowed emergency diesel generator frequency variation.  Specifically, the motor driven auxiliary feedwater pump surveillance procedures would allow a pump with degraded and unacceptable performance to meet the test acceptance criteria based upon the test being performed at nominal frequency and not accounting for potentially lower, allowable, emergency diesel generator frequency.  
| description = The inspectors identified a Green finding and an associated Non-Cited Violation (NCV)of Title 10 of the Code of Federal Regulations (CFR),Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the failure to prescribe motor driven auxiliary feedwater pump test procedures that accounted for the allowed emergency diesel generator frequency variation.  Specifically, the motor driven auxiliary feedwater pump surveillance procedures would allow a pump with degraded and unacceptable performance to meet the test acceptance criteria based upon the test being performed at nominal frequency and not accounting for potentially lower, allowable, emergency diesel generator frequency.  
}}
}}

Latest revision as of 17:35, 10 September 2018

01
Site: Byron Constellation icon.png
Report IR 05000454/2018010 Section 1R21
Date counted Mar 31, 2018 (2018Q1)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: NRC identified
Inspection Procedure: IP 71111.21M
Inspectors (proximate) N Feliz-Adorno
J Benjamin
J Robbins
G O'Dwyer
S Kobylarz
C Baron
V Petrella
J Corujo-Sandin
M Jeffers
Violation of: 10 CFR 50 Appendix B Criterion V
INPO aspect PI.2
'