05000454/FIN-2017007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Fai lure to Perform Maintenance in Accordance with Performance Centered Maintenance Template |
Description | The inspectors identified a finding of very low safety significance and an associated NCV of TS 5.4.1, Procedures, when licensee personnel failed to perform maintenance in accordance with written procedures as required by Regulatory Guide 1.33. Specifically, from February 3, 2014, through August 25, 2017, the licensee failed to develop and execute work instructions of sufficient scope to accomplish the 3 preventive maintenance to replace flexible hoses on the essential service water (SX) makeup pumps and the diesel driven auxiliary feedwater (AFW) pumps and did not have a technical justification for a deviation from the Exelon Corporate Performance Centered Maintenance (PCM) template. The licensee entered this issue into their CAP as Action Request (AR) 03961955, AR 03971962, and AR 04045769 and planned to replace the flexible hoses at the next available opportunity. The inspectors determined that failure to perform maintenance in accordance with written procedures as required by TS 5.4.1, Procedures, and Regulatory Guide 1.33 was a performance deficiency. The performance deficiency was more than minor because it was associated with the Mitigating Systems cornerstone attribute of Equipment Performance and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences . Specifically, failing to replace flexible hoses on the SX makeup pumps and the Unit 1 and Unit 2 diesel -driven AFW pumps at a pre - established frequency could allow hose degradation to remain unidentified and lead to the unplanned inoperability of these safety-related systems. Since the finding is a deficiency affecting the design or qualification of mitigating systems, structures and components (SSC s) and the SSC s remained operable and functional, the finding screened as having very low safety significance. This finding affected the C ross -Cutting area of Human Performance in the aspect of Work Management because the licensee failed to perform required maintenance in accordance with their associated maintenance strategy as well as the corporate PCM template [H.5] . |
Site: | Byron |
---|---|
Report | IR 05000454/2017007 Section 4OA2 |
Date counted | Sep 30, 2017 (2017Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | R Ng C Hunt C Norton A Dunlop G Edwards C Thompson E Duncan |
Violation of: | Technical Specification - Procedures |
CCA | H.5, Work Management |
INPO aspect | WP.1 |
' | |
Finding - Byron - IR 05000454/2017007 | |||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Byron) @ 2017Q3
Self-Identified List (Byron)
| |||||||||||||||||||||||||||||||||||