ENS 52973: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 09/16/2017 13:30 EDT
| event date = 09/16/2017 13:30 EDT
| last update date = 09/16/2017
| last update date = 09/16/2017
| title = Loss Of Secondary Containment Differential Pressure
| title = Loss of Secondary Containment Differential Pressure
| event text = On September 16th, 2017 at 1330 hrs. [EDT], a loss of secondary containment differential pressure (D/P) occurred due to an equipment failure.  This caused a reduction in Reactor Building Zone 2 (Unit 2) D/P to less than the required 0.25 inches WC per SR [Surveillance Requirement] 3.6.4.1.1.  
| event text = On September 16th, 2017 at 1330 hrs. [EDT], a loss of secondary containment differential pressure (D/P) occurred due to an equipment failure.  This caused a reduction in Reactor Building Zone 2 (Unit 2) D/P to less than the required 0.25 inches WC per SR [Surveillance Requirement] 3.6.4.1.1.  
2V206B, Reactor Building Zone 2 Equipment Compartment Exhaust Fan, was manually started and Reactor Building Zone 2 D/P was restored to greater than 0.25 inches WC by 1333 hrs.  
2V206B, Reactor Building Zone 2 Equipment Compartment Exhaust Fan, was manually started and Reactor Building Zone 2 D/P was restored to greater than 0.25 inches WC by 1333 hrs.  

Latest revision as of 21:41, 1 March 2018

ENS 52973 +/-
Where
Susquehanna Talen Energy icon.png
Pennsylvania (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material
LER: 05000388/LER-2017-009
Time - Person (Reporting Time:+-1.62 h-0.0675 days <br />-0.00964 weeks <br />-0.00222 months <br />)
Opened: Lonnie Crawford
15:53 Sep 16, 2017
NRC Officer: Howie Crouch
Last Updated: Sep 16, 2017
52973 - NRC Website
Loading map...