| title = Browns Ferry Nuclear Plant Updated Final Safety Analysis Report (Ufsar), Amendment 27, 10.21 Table - Postaccident Sampling
| title = Updated Final Safety Analysis Report (Ufsar), Amendment 27, 10.21 Table - Postaccident Sampling
| author name =  
| author name =  
| author affiliation = Tennessee Valley Authority
| author affiliation = Tennessee Valley Authority
Line 14: Line 14:
| page count = 1
| page count = 1
}}
}}
=Text=
{{#Wiki_filter:BFN-16 Table 10.21-1 PASS In-Line Instrumentation Liquid Sample Mode Instrument                  Description        Range            Purpose FI-664                      Flow                0-2 gpm          Line flush flow rate CI-663                      Conductivity        0-10 s/gpm      Sample conductivity PI-661                      Pressure            0-1200 psig      Sample pressure PI-662                      Pressure            0-150 psia      Dissolved gas collect-ion chamber pressure RI-665                      Radiation          10-100,000 mr/hr Approximate radiation level of sample line in liquid sampler, used also to verify system flush TI-660                      Temperature        50-150°F        Sample line temperature Gas Sample Mode Instrument                  Description        Range            Purpose FI-725                      Flow                2-25 slpm        Calibrate pump dis-charge pressure versus sample flow rate (not used during normal operation PI-708                      Pressure            0-50 psia        Sample pressure TI-724                      Temperature        50-150°F        Sample line temperature}}

Latest revision as of 03:26, 22 October 2019

Updated Final Safety Analysis Report (Ufsar), Amendment 27, 10.21 Table - Postaccident Sampling
ML18023A475
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 10/05/2017
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18018A778 List: ... further results
References
Download: ML18023A475 (1)


Text

BFN-16 Table 10.21-1 PASS In-Line Instrumentation Liquid Sample Mode Instrument Description Range Purpose FI-664 Flow 0-2 gpm Line flush flow rate CI-663 Conductivity 0-10 s/gpm Sample conductivity PI-661 Pressure 0-1200 psig Sample pressure PI-662 Pressure 0-150 psia Dissolved gas collect-ion chamber pressure RI-665 Radiation 10-100,000 mr/hr Approximate radiation level of sample line in liquid sampler, used also to verify system flush TI-660 Temperature 50-150°F Sample line temperature Gas Sample Mode Instrument Description Range Purpose FI-725 Flow 2-25 slpm Calibrate pump dis-charge pressure versus sample flow rate (not used during normal operation PI-708 Pressure 0-50 psia Sample pressure TI-724 Temperature 50-150°F Sample line temperature