ENS 56221: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 21: Line 21:
This event is being reported as an eight-hour non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).
This event is being reported as an eight-hour non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).
There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified.
There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/20221115en.html#en56221
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/20221116en.html#en56221
}}{{unit info
}}{{unit info
| Unit = 1
| Unit = 1

Latest revision as of 07:30, 16 November 2022

ENS 56221 +/-
Where
Oconee Duke Energy icon.png
South Carolina (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded
LER: 05000269/LER-1922-002
Reactor Coolant Oconee Nuclear Station
Unit 1
System Pressure Boundary Leak on Reactor Coolant Pump Lower Bearing Thermowell
Time - Person (Reporting Time:+1.58 h0.0658 days <br />0.0094 weeks <br />0.00216 months <br />)
Opened: Paul Marshall
13:05 Nov 14, 2022
NRC Officer: Donald Norwood
Last Updated: Nov 14, 2022
56221 - NRC Website
Loading map...