{{#Wiki_filter:June 2, 2021 Mr. Philip Sewell Senior Engineer 8161 Maple Lawn Boulevard Suite 450 Fulton, MD 20759 | {{#Wiki_filter:June 2, 2021 Mr. Philip Sewell Senior Engineer 8161 Maple Lawn Boulevard Suite 450 Fulton, MD 20759 | ||
==SUBJECT:== | ==SUBJECT:== | ||
APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION | APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION | ||
==Dear Mr. Sewell:== | ==Dear Mr. Sewell:== | ||
By {{letter dated|date=February 17, 2021|text=letter dated February 17, 2021}} (Agencywide Documents Access and Management System Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package per the details of the submitted revision of the safety analysis report, Revision 12. In connection with the U.S. Nuclear Regulatory Commission staff review, we need the information identified in the enclosure to this letter. Additional information requested by this letter should be submitted in the form of revised pages. | By {{letter dated|date=February 17, 2021|text=letter dated February 17, 2021}} (Agencywide Documents Access and Management System Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package per the details of the submitted revision of the safety analysis report, Revision 12. In connection with the U.S. Nuclear Regulatory Commission staff review, we need the information identified in the enclosure to this letter. Additional information requested by this letter should be submitted in the form of revised pages. | ||
In order to complete our technical review on schedule, please provide your response within one month of the date of this letter. If you have any questions regarding this matter, I may be contacted at (301) 415-5196. | In order to complete our technical review on schedule, please provide your response within one month of the date of this letter. If you have any questions regarding this matter, I may be contacted at (301) 415-5196. | ||
Sincerely, Nishka J. Devaser, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9342 EPID L-2021-LLA-0024 | Sincerely, Nishka J. Devaser, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9342 EPID L-2021-LLA-0024 | ||
==Enclosure:== | ==Enclosure:== | ||
Request for Additional Information | |||
P. Sewell 2 | |||
2 | |||
P. Sewell | |||
==SUBJECT:== | ==SUBJECT:== | ||
APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION DATE: _June 2, 2021_ | APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION DATE: _June 2, 2021_ | ||
DISTRIBUTION: | DISTRIBUTION: | ||
D. Marcano | D. Marcano ADimitriadis, RI BBonser, RII MKunowski, RIII GWarnick, RIV | ||
* by email | * by email ADAMS Memo Accession Number: ML21153A044 OFFICE DFM DFM DFM DFM DFM NAME NDevaser SFigueroa JSolis ZCruzPerez JMcKirgan DATE 05/26/2021 05/26/2021 06/01/2021 06/01/2021 06/02/2021 OFFICIAL RECORD COPY | ||
Request for Additional Information Daher-TLI Docket No. 71-9342 Certificate of Compliance No. 9342 Versa-Pac Transportation Package By {{letter dated|date=February 17, 2021|text=letter dated February 17, 2021}} (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package. This request for additional information identifies information needed by the U.S. Nuclear Regulatory Commission staff in connection with its review of the safety analysis report (SAR or the application). The staff used guidance provided in NUREG-1609, "Standard Review Plan for Transportation Packages for Radioactive Material, in its review of the application. | Enclosure Request for Additional Information Daher-TLI Docket No. 71-9342 Certificate of Compliance No. 9342 Versa-Pac Transportation Package By {{letter dated|date=February 17, 2021|text=letter dated February 17, 2021}} (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package. This request for additional information identifies information needed by the U.S. Nuclear Regulatory Commission staff in connection with its review of the safety analysis report (SAR or the application). The staff used guidance provided in NUREG-1609, "Standard Review Plan for Transportation Packages for Radioactive Material, in its review of the application. | ||
The question describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements. | The question describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements. | ||
Chapter 3: Thermal Analysis 3-1 | Chapter 3: Thermal Analysis 3-1 Justify the heat transfer coefficient value used to perform the analysis of the 30-minute regulatory fire. | ||
SAR Section 3.5.3.5.1 Fire Test Conditions states that forced convection heat transfer is used with a convection coefficient of 10 W/m-°C. This value may not be adequate for the regulatory fire as use of a lower heat transfer coefficient value may result in nonconservative predicted temperatures. The staff needs this information to determine that predicted temperatures and pressures remain below allowable limits during hypothetical accident conditions. | SAR Section 3.5.3.5.1 Fire Test Conditions states that forced convection heat transfer is used with a convection coefficient of 10 W/m-°C. This value may not be adequate for the regulatory fire as use of a lower heat transfer coefficient value may result in nonconservative predicted temperatures. The staff needs this information to determine that predicted temperatures and pressures remain below allowable limits during hypothetical accident conditions. | ||
For reference, Sandia Report Thermal Measurements in a Series of Large Pool Fires, Sandia Report SAND85- 0196 TTC - 0659 UC 71, (August 1971) measured a higher value of about 25.5 W/m2-°C for this type of fire. | For reference, Sandia Report Thermal Measurements in a Series of Large Pool Fires, Sandia Report SAND85- 0196 TTC - 0659 UC 71, (August 1971) measured a higher value of about 25.5 W/m2-°C for this type of fire. | ||
Note: The units used in the heat transfer coefficients on SAR Section 3.5.3.5.1 appear to be incorrect and should be revised. | Note: The units used in the heat transfer coefficients on SAR Section 3.5.3.5.1 appear to be incorrect and should be revised. | ||
This information is needed to determine compliance with 10 CFR 71.73(c)(4). | This information is needed to determine compliance with 10 CFR 71.73(c)(4).}} | ||
Latest revision as of 08:41, 29 November 2024
ML21153A044 | |
Person / Time | |
---|---|
Site: | 07109342 |
Issue date: | 06/02/2021 |
From: | Nishka Devaser Storage and Transportation Licensing Branch |
To: | Sewell P - No Known Affiliation |
NJDevaser NMSS/DFM/STL 301.415.5196 | |
References | |
EPID L-2021-LLA-0024 | |
Download: ML21153A044 (3) | |
Text
June 2, 2021 Mr. Philip Sewell Senior Engineer 8161 Maple Lawn Boulevard Suite 450 Fulton, MD 20759
SUBJECT:
APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION
Dear Mr. Sewell:
By letter dated February 17, 2021 (Agencywide Documents Access and Management System Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package per the details of the submitted revision of the safety analysis report, Revision 12. In connection with the U.S. Nuclear Regulatory Commission staff review, we need the information identified in the enclosure to this letter. Additional information requested by this letter should be submitted in the form of revised pages.
In order to complete our technical review on schedule, please provide your response within one month of the date of this letter. If you have any questions regarding this matter, I may be contacted at (301) 415-5196.
Sincerely, Nishka J. Devaser, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9342 EPID L-2021-LLA-0024
Enclosure:
Request for Additional Information
P. Sewell 2
2
SUBJECT:
APPLICATION FOR AMENDMENT REQUEST OF CERTIFICATE OF COMPLIANCE NO. 9342 FOR THE MODEL NO. VERSA-PAC - REQUEST FOR ADDITIONAL INFORMATION DATE: _June 2, 2021_
DISTRIBUTION:
D. Marcano ADimitriadis, RI BBonser, RII MKunowski, RIII GWarnick, RIV
- by email ADAMS Memo Accession Number: ML21153A044 OFFICE DFM DFM DFM DFM DFM NAME NDevaser SFigueroa JSolis ZCruzPerez JMcKirgan DATE 05/26/2021 05/26/2021 06/01/2021 06/01/2021 06/02/2021 OFFICIAL RECORD COPY
Enclosure Request for Additional Information Daher-TLI Docket No. 71-9342 Certificate of Compliance No. 9342 Versa-Pac Transportation Package By letter dated February 17, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21049A137), Daher-TLI submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 71 to amend Certificate of Compliance No. 9342 for the Model No. Versa-Pac package. This request for additional information identifies information needed by the U.S. Nuclear Regulatory Commission staff in connection with its review of the safety analysis report (SAR or the application). The staff used guidance provided in NUREG-1609, "Standard Review Plan for Transportation Packages for Radioactive Material, in its review of the application.
The question describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements.
Chapter 3: Thermal Analysis 3-1 Justify the heat transfer coefficient value used to perform the analysis of the 30-minute regulatory fire.
SAR Section 3.5.3.5.1 Fire Test Conditions states that forced convection heat transfer is used with a convection coefficient of 10 W/m-°C. This value may not be adequate for the regulatory fire as use of a lower heat transfer coefficient value may result in nonconservative predicted temperatures. The staff needs this information to determine that predicted temperatures and pressures remain below allowable limits during hypothetical accident conditions.
For reference, Sandia Report Thermal Measurements in a Series of Large Pool Fires, Sandia Report SAND85- 0196 TTC - 0659 UC 71, (August 1971) measured a higher value of about 25.5 W/m2-°C for this type of fire.
Note: The units used in the heat transfer coefficients on SAR Section 3.5.3.5.1 appear to be incorrect and should be revised.
This information is needed to determine compliance with 10 CFR 71.73(c)(4).