ACRS Fc NRC Staff Public LTR BWRx-300 Containment Performance Final Slides
ML21028A443
Person / Time
Issue date: 01/28/2021
From:
NRC/NRR/DNRL/NRLB
To:
Shea J
References
Download: ML21028A443 (6)


Text

NRC Staff Presentation-Open Session GEH Topical Report NEDC-33911P, Revision 0, Supplement 1, BWRX-300 Containment Performance BWRX-300 Small Modular Reactor ACRS Subcommittee Meeting February 3, 2021 1

Presentation Outline

  • NRC Staff Review Team
  • BWRX-300 Containment Background

NRC Staff Review Team

  • NRR Containment and Plant Systems Branch (SCPB)

- Chang-Yang Li

- Angelo Stubbs

  • NRR Nuclear Systems Performance Branch (SNSB)

- Syed Haider

  • NRR Mechanical Engineering and Inservice Testing Branch (EMIB)

- Yueh-Li (Renee) Li

- Thomas Scarbrough

  • NRR Vessels and Internals Branch (NVIB)

- Dan Widrevitz

  • NRR New Reactor Licensing Branch (NRLB)

- Rani Franovich

- George Wunder 3

BWRX-300 Containment Design Background

  • BWRX-300 containment is an underground subterranean steel or reinforced concrete primary containment vessel (PCV) or a combination of steel and reinforced concrete
  • Containment heat is removed by Passive Containment Cooling System (PCCS)
  • Combustible gas control is not required for design basis accidents (DBAs) because the BWRX-300 containment atmosphere is well mixed and the containment atmosphere is initially nitrogen-inerted 4

BWRX-300 Containment Performance NEDC-33911P provides design requirements, analytical methods, acceptance criteria, and regulatory bases for:

  • Containment and the Passive Containment Cooling System (PCCS)
  • Containment isolation valves (CIVs)
  • Analytical methods evaluating containment performance
  • Acceptance criteria for the BWRX-300 containment performance in accordance with the design requirements specified for the containment, PCCS, and CIVs 5

Overview of NRC Staff Review

  • Piping and Valves Design Relevant to Containment Performance
  • Containment Functional Design
  • Containment Heat Removal Systems
  • Containment Isolation System
  • Combustible Gas Control in Containment
  • Containment Leakage Testing
  • Fracture Prevention of Containment Pressure Boundary 6