{{#Wiki_filter:U.S. NUCLEAR REGULATORY COMMISSION Revision 11 October 1994 REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.147 INSERVICE INSPECTION CODE CASE ACCEPTABILITY ASME SECTION XI DIVISION 1 A. INTRODUCTION Section 50.55a, "Codes and Standards," of 10 CFR Part 50, "Domestic Licensing of Production and Utilization Facilities," requires, in part, that each operating license for a boiling or pressurized water cooled nuclear power facility and each construction permit for a utilization facility be subject to the condi tions in paragraph (g), "Inservice Inspection Require ments," of § 50.55a. Paragraph (g) requires, in part, that Classes 1, 2, and 3 components and their supports meet the requirements of Section XI, "Rules for Inser vice Inspection of Nuclear Power Plant Compo nents,"' of the American Society of Mechanical Engi neers (ASME) Boiler and Pressure Vessel Code or equivalent quality standards.
{{#Wiki_filter:U.S. NUCLEAR REGULATORY COMMISSION                                                                 Revision 11 October 1994 C-')                                    REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.147 INSERVICE INSPECTION CODE CASE ACCEPTABILITY ASME SECTION XI DIVISION 1 A. INTRODUCTION                                                 General Design Criterion 1, "Quality Standards and Records," of Appendix A, "General Design Section 50.55a, "Codes and Standards," of                                 Criteria for Nuclear Power Plants," to 10 CFR Part 50 10 CFR Part 50, "Domestic Licensing of Production                               requires, in part, that structures, systems, and compo and Utilization Facilities," requires, in part, that each                       nents important to safety be designed, fabricated, operating license for a boiling or pressurized water                             erected, and tested to quality standards commensurate cooled nuclear power facility and each construction                             with the importance of the safety function to be per permit for a utilization facility be subject to the condi                       formed. Where generally recognized codes and stan tions in paragraph (g), "Inservice Inspection Require                           dards are used, Criterion 1 requires that they be identi ments," of § 50.55a. Paragraph (g) requires, in part,                            fied and evaluated to determine their applicability, that Classes 1, 2, and 3 components and their supports                           adequacy, and sufficiency and be supplemented or meet the requirements of Section XI, "Rules for Inser                           modified as necessary to ensure a quality product in vice Inspection of Nuclear Power Plant Compo                                     keeping with the required safety function.
Paragraph 50.55a(b), in part, references the latest editions and addenda in ef fect of Section XI of the Code and any supplementary requirements to that section of the Code. Footnote 6 to § 50.55a states that the use of specific Code Cases may be authorized by the Commission upon request pursuant to paragraph 50.55a(a)(3), which requires that proposed alternatives to the described require ments or portions thereof provide an acceptable level of quality and safety. 'Copies may be obtained from the American Society of Me chanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017.USNRC REGULATORY GUIDES Regulatory Guides are Issued to describe and make available to the public such Information as methods acceptable to the NRC staff for Implement Ing specific parts of the Commission's regulations, techniques used by the staff In evaluating specific problems or postulated accidents, and data needed by the NRC staff In Its review of applications for permits and licenses.
nents,"' of the American Society of Mechanical Engi                                     This regulatory guide lists those Section XI ASME neers (ASME) Boiler and Pressure Vessel Code or                                 Code Cases that are generally acceptable to the NRC equivalent quality standards. Paragraph 50.55a(b), in                           staff for implementation in the inservice inspection of part, references the latest editions and addenda in ef                           light-water-cooled nuclear power plants.
Regulatory Guides are not substitutes for regulations, and com pliance with them Is not required Methods and solutions different from those set out In the guides will be acceptable If they provide a basis for the findings requisite to the Issuance or continuance of a permit or license by the Commission This guide was Issued after consideration of comments received from the public. Comments and suggestions for Improvements In these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new Information or experience.
fect of Section XI of the Code and any supplementary This regulatory guide contains no information col requirements to that section of the Code. Footnote 6 lection activities and, therefore, is not subject to the to § 50.55a states that the use of specific Code Cases requirements of the Paperwork Reduction Act of 1980 may be authorized by the Commission upon request (44 U.S.C. 3501 et seq.).
Written comments may be submitted to the Rules Review and Directives Branch, DFIPS, ADM, U.S. Nuclear Regulatory Commission, Washing ton, DC 20555-0001.
pursuant to paragraph 50.55a(a)(3), which requires that proposed alternatives to the described require                                                       B. DISCUSSION ments or portions thereof provide an acceptable level of quality and safety.                                                                 The ASME Boiler and Pressure Vessel Committee 1
General Design Criterion 1, "Quality Standards and Records," of Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50 requires, in part, that structures, systems, and compo nents important to safety be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety function to be per formed. Where generally recognized codes and stan dards are used, Criterion 1 requires that they be identi fied and evaluated to determine their applicability, adequacy, and sufficiency and be supplemented or modified as necessary to ensure a quality product in keeping with the required safety function.
publishes a document entitled "Code Cases." Gener ally, the individual Code Cases that make up this docu
This regulatory guide lists those Section XI ASME Code Cases that are generally acceptable to the NRC staff for implementation in the inservice inspection of light-water-cooled nuclear power plants. This regulatory guide contains no information col lection activities and, therefore, is not subject to the requirements of the Paperwork Reduction Act of 1980 (44 U.S.C. 3501 et seq.). B. DISCUSSION The ASME Boiler and Pressure Vessel Committee publishes a document entitled "Code Cases." 1 Gener ally, the individual Code Cases that make up this docu ment explain the intent of Code rules or provide for alternative requirements under special circumstances.
          'Copies may be obtained from the American Society of Me                      ment explain the intent of Code rules or provide for chanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017.                                                      alternative requirements under special circumstances.
The guides are Issued In the following ten broad divisions:
The guides are Issued In the following ten broad divisions:
: 1. Power Reactors 2. Research and Test Reactors 3. Fuels and Materials Facilities
USNRC REGULATORY GUIDES Regulatory Guides are Issued to describe and make available to the public such Information as methods acceptable to the NRC staff for Implement          1. Power Reactors                     6. Products
: 4. Environmental and Siting 5. Materials and Plant Protection
: 7. Transportation Ing specific parts of the Commission's regulations, techniques used by          2. Research and Test Reactors
: 6. Products 7. Transportation
: 8. Occupational Health the staff In evaluating specific problems or postulated accidents, and          3. Fuels and Materials Facilities Environmental and Siting          g. Antitrust and Financial Review data needed by the NRC staff In Its review of applications for permits and      4.
: 8. Occupational Health g. Antitrust and Financial Review 10 General Copies of Issued guides may be purchased from the Government Printing Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of Documents, U.S. Government Printing Office, Mali Stop SSOP, Washington, DC 20402-9328, telephone (202)512-2249 or (202)512-2171.
10  General licenses. Regulatory Guides are not substitutes for regulations, and com        5. Materials and Plant Protection pliance with them Is not required Methods and solutions different from those set out In the guides will be acceptable If they provide a basis for the  Copies of Issued guides may be purchased from the Government Printing findings requisite to the Issuance or continuance of a permit or license by the Commission                                                                  Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of Documents, U.S.
Issued guides may also be purchased from the National Technical Infor mation Service on a standing order basis. Details on this service may be obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161.C-')
This guide was Issued after consideration of comments received from the          Government Printing Office, Mali Stop SSOP, Washington, DC public. Comments and suggestions for Improvements In these guides are          20402-9328, telephone (202)512-2249 or (202)512-2171.
Most Code Cases are eventually superseded by revision of the Code and then are annulled by action of the ASME. In such instances, the intent of the an nulled Code Case becomes part of the revised Code, and therefore continued use of the Code Case intent is sanctioned under the rules of the Code. In other in stances, the Code Case is annulled because it is no longer acceptable or there is no further requirement for it. A Code Case that was approved for a particular situation and not for a generic application should be used only for the approved situation because annul ment of such a Code Case could result in situations that would not meet Code requirements.
encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new Information or experience.
The ASME con siders the use of Code Cases to be optional for the user and not a mandatory requirement.
Issued guides may also be purchased from the National Technical Infor Written comments may be submitted to the Rules Review and Directives            mation Service on a standing order basis. Details on this service may be Branch, DFIPS, ADM, U.S. Nuclear Regulatory Commission, Washing                  obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161.
The Code Cases listed in this guide are limited to those cases applicable to Section XI of the Code. All published Code Cases that are applicable to Section XI of the Code and were in effect on July 28, 1992, were reviewed for inclusion in this guide. Code Cases that are not listed herein are either not endorsed or will require supplementary provisions on an individ ual plant basis to attain endorsement status. The endorsement of a Code Case by this guide constitutes acceptance of its technical position for ap plications not precluded by regulatory or other require ments or by the recommendations in this or other regu latory guides. Contingent endorsement if applicable is indicated in regulatory position I for specific cases. However, it is the responsibility of the user to make certain that no regulatory requirements are violated and that there are no conflicts with other recom mended limitations resulting from Code Case usage. Acceptance or endorsement by the NRC staff ap plies only to those Code Cases or Code Case revisions with the date of ASME approval as shown in the regu latory position of this guide. Earlier or later revisions of a Code Case are not endorsed by this guide. New Code Cases will require evaluation by the NRC staff to deter mine if they qualify for inclusion in the approved list. Because of the continuing change in the status of Code Cases, it is planned that this guide will require periodic updating to accommodate new Code Cases and any revision of existing Code Cases. C. REGULATORY POSITION 1. ACCEPTABLE CODE CASES The Section XI ASME Code Cases 2 listed below (by number, date of ASME approval, 3 and title) are *Lines indicate substantive changes from Revision 10. 2 A numerical listing of the Code Cases appears in the appen dix. 3When more than one date is given, the earlier date is that on which the Code Case was approved by the ASME, and the later date (or dales) is that on which the Code Case was reaffirmed by the ASME.acceptable to the NRC staff for application in the inser vice inspection of components and their supports for water-cooled nuclear power plants. Their use is accept able within the limitations stated in the "Inquiry" and "Reply" sections of each individual Code Case, within the limitations of such NRC or other requirements as may exist, and within the additional limitations recom mended by the NRC staff and given with the individual Code Case in the list. 1705-1 3-1-76 N-98 11-20-78 1-21-82 12-5-84 12-5-87 12-3-90 N-113-1 12-13-82 2-14-85 2-14-88 12-3-90 N-211 4  7-13-81 7-13-84 5-7-87 4-30-90 N-235 1-8-79 4-2-82 2-14-85 2-14-88 12-3-90 N-236-1 9-5-85 9-5-88 8-14-91 N-307-1 12-5-84 12-5-87 12-3-90 N-311 5-11-81 4-5-84 5-7-87 4-30-90 Ultrasonic Calibration Section XI Examination Block Tolerances, Basic Calibration Block for Ultrasonic Examination of Welds 10 in. to 14 in. Thick, Section XI, Division 1 Recalibration of Ultrasonic Equipment Upon Change of Personnel, Section XI, Divi sion 1 Ultrasonic Calibration Checks per Section V, Section XI, Di vision 1 Repair and Replacement of Class MC Vessels, Section XI, Division 1 Revised Ultrasonic Examina tion Volume for Class 1 Bolt ing, Table IWB-2500-1, Ex amination Category B-G-1, When the Examinations Are Conducted from the Center Drilled Hole, Section XI, Division 1 Alternative Examination of Outlet Nozzle on Secondary Side of Steam Generators, Section XI, Division 1 Code Case N-311 is acceptable subject to the fol lowing condition in addition to those conditions specified in the Code Case: The applicant should indicate in the Safety Analysis Report that the stress analysis of the nozzle inside-corner region meets the Code Case stipulations for the state of stress in this region. 4 The Code Case was annulled on 3-20-81 (ASME mandatory annulment date). It was reinstated on 7-13-81. Because there was no change in the Code Case, the NRC considers that the Case was in effect during the period 3-20-81 through 7-13-81.1.147-2 N-335-1 6-20-85 Rules for Ultrasonic Exami 6-20-88 nation of Similar and Dissimi 5-13-91 lar Metal Piping Welds, Sec tion XI, Division 1 N-355 7-16-82 Calibration Block for Angle 2-14-85 Beam Ultrasonic Examination 2-14-88 of Large Fittings in Accor 12-3-90 dance with Appendix III 3410, Section XI, Division 1 N-356 7-1-885 Certification Period for Level 10-23-88 III NDE Personnel, Section XI, Division 1, 2 and 3 N-389 7-25-83 Alternative Rules for Repairs, 5-14-86 Replacements, or Modifica 5-14-89 tions, Section XI, Division 1 2-5-92 Code Case N-389 is acceptable subject to the fol lowing condition in addition to those conditions specified in the Code Case: The applicant should submit for approval the appropriate edition and addenda of the Code that is to be used for the re pair, replacement, or modification before start of the work. N-401-1 5-4-88 Eddy Current Examination, 5-13-91 Section XI, Division 1 N-402-1 3-14-91 Eddy Current Calibration Standards, Section XI, Division 1 N-408-2 7-24-89 Alternative Rules for Exami nation of Class 2 Piping, Sec tion XI, Division 1 Code Case N-408-2 is acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant for an operating license should define the Class 2 piping subject to volumetric and surface examination in the Preservice Inspection for determination of ac ceptability by the NRC staff. N-409-2 7-27-88 Procedure and Personnel 5-13-91 Qualification Requirements for Ultrasonic Detection and Sizing of Flaws in Piping Welds, Section XI, Division 1 Code Case N-409-2 is acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant should give prior notification to the NRC of the intention to use the Code Case.N-415 9-5-85 9-5-88 8-14-91 Alternative Rules for Testing Pressure Relief Devices, Sec tion XI, Division 1 5July 1, 1988, is the date that the conditions of the Code Case were acceptable to the NRC.N-416 12-5-85 12-5-87 12-3-90 N-419 7-18-85 7-18-88 5-13-91 N-426 7-18-85 7-18-88 5-13-91 N-427 12-5-85 12-5-88 12-16-91 Alternative Rules for Hydro static Testing of Repair or Re placement of Class 2 Piping, Section XI, Division 1 Extent of VT-1 Examinations, Category B-G-1 of Table IWB-2500-1, Section XI, Di vision 1 Extent of VT-1 Examinations, Category B-G-2 of Table IWB-2500-1, Section XI, Di vision 1 Code Cases in Inspection Plans, Section XI, Division 1 I 1.147-3 Code Case N-427 is acceptable subject to the fol lowing condition in addition to those conditions specified in the Code Case. The sentence under (b)(1) should be replaced with the following:
ton, DC 20555-0001.
Code Cases that were superseded with revised Code Cases and had been approved for use in ac cordance with (a) may continue to be used. N-429-1 2-23-87 Alternative Rules for Ultra 3-5-90 sonic Instrument Calibration, Section XI, Division 1 N-432 2-20-86 Repair Welding Using Auto 2-20-89 matic or Machine Gas o 12-16-91 Tungsten-Arc Welding (GTAW) Temperbead Tech nique, Section XI, Division 1 N-435-1 7-30-86 Alternative Examination Re 7-30-89 quirements for Vessels with Wall Thickness 2 in. or less, Section XI, Division 1 N-437 7-30 86 Use of Digital Readout and 7-30-89 Digital Measurement Devices for Performing Pressure Tests, Section XI, Division 1 N-448 7-27-87 Qualification of VT-2 and 4-30-90 VT-3 Visual Examination Per sonnel, Section XI, Division 1 N-449 7-27-87 Qualification of VT-4 Visual 4-30-90 Examination Personnel, Sec tion XI, Division 1 N-457 12-7-87 Qualification Specimen Notch 12-3-90 Location for Ultrasonic Ex amination of Bolts and Studs, Section XI, Division 1 N-458 8-14-90 Magnetic Particle Examina tion of Coated Materials, Section XI, Division 1 N-460 7-27-88 Alternative Examination Cov 5-13-91 erage for Class 1 and Class 2 Welds, Section XI, Divi sion 1 N-461 11-30-88 Alternative Rules for Piping 8-14-91 Calibration Block Thickness, Section XI, Division 1 Code Case N-461 is acceptable subject to the following condition in addition to those conditions specified in the Code Case: Thickness measure ments and weld joint contour of the pipe/compo nent must be known and used by the inspector who conducts the UT examination.
 
N-463-1 3-5-90 Evaluation Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping That Exceed the Acceptance Standards of IWB-3514.2, Section XI, Division 1 N-465 11-30-88 Alternative Rules for Pump 8-14-91 Testing, Section XI, Divi sion 1 N-471 4-30-90 Accoustic Emission for Suc cessive Inspections, Section XI, Division 1 Code Case N-471 is acceptable subject to the following conditions in addition to those specified in the Code Case: The first successive examination required by IWB-2420 or IWC-2420 shall be per formed. The owner shall evaluate the results of the on-line acoustic emission monitoring to confirm that the conclusions from the acoustic emission data represent the condition of the flaw indication as estimated from the first successive ISI Examin ation and the data can be correlated with the known plant operating environment.
Most Code Cases are eventually superseded by                     acceptable to the NRC staff for application in the inser revision of the Code and then are annulled by action of               vice inspection of components and their supports for the ASME. In such instances, the intent of the an                     water-cooled nuclear power plants. Their use is accept nulled Code Case becomes part of the revised Code,                     able within the limitations stated in the "Inquiry" and and therefore continued use of the Code Case intent is                 "Reply" sections of each individual Code Case, within sanctioned under the rules of the Code. In other in                   the limitations of such NRC or other requirements as stances, the Code Case is annulled because it is no                   may exist, and within the additional limitations recom longer acceptable or there is no further requirement                   mended by the NRC staff and given with the individual for it. A Code Case that was approved for a particular                 Code Case in the list.
N-472 3-8-89 Use of Digital Readout and 12-16-91 Digital Measurement Devices for Performing Pump Vibra tion Testing, Section XI, Divi sion 1 N-473 N-479-1 3-8-89 Alternative Rules for Valve 12-16-91 Testing, Section XI, Division 1 12-3-90 Boiling Water Reactor (BWR) Main Steam Hydrostatic Test, Section XI, Division 1 N-481 3-5-90 Alternate Examination Re quirements for Cast Austeni tic Pump Casings, Section XI, Division 1 N-485-1 8-14-91 Eddy Current Examination of Coated Ferritic Surfaces as an Alternative to Surface Exam ination, Section XI, Divi sion 1 N-489 8-14-90 Alternative Rules for Level III NDE Qualification Examina-tions, Section XI, Divisions 1, 2, and 3 N-490-1 5-13-91 Alternative Vision Test Re quirements for Nondestructive Examiners, Section XI, Divisions 1, 2, and 3 N-491 3-14-91 Alternative Rules for Exami nation of Class 1, 2, 3 and MC Component Supports of Light-Water Cooled Power Plants, Section XI, Division 1 N-494-1 7-27-92 Pipe Specific Evaluation Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping that Exceeds the Acceptance Standards of IWB-3514.2, Section XI, Division 1 N-495 12-3-90 Hydrostatic Testing of Relief Valves, Section XI, Division 1 N-496 3-14-91 Helical Coil Threaded Inserts, Section XI, Division 1 N-498 6  5-13-91 Alternative Rules for 10-Year Hydrostatic Pressure Testing for Class 1 and 2 Systems, Section XI, Division 1 N-503 2-5-92 Limited Certification of Non destructive Examination Per sonnel, Section XI, Division 1 N-504 4-30-92 Alternative Rules for Repair of Class 1, 2, and 3 Austenitic Stainless Steel Piping, Section XI, Division 1 2. ANNULLED CODE CASES Code Cases that were endorsed by the NRC in a prior version of this guide and were later annulled by action of the ASME should be considered as deleted from the list of acceptable Code Cases as of the date of the ASME action that approved the annulment.
situation and not for a generic application should be used only for the approved situation because annul                     1705-1      3-1-76        Ultrasonic        Examination ment of such a Code Case could result in situations that               N-98          11-20-78    Calibration Block Tolerances, would not meet Code requirements. The ASME con                                       1-21-82      Section XI siders the use of Code Cases to be optional for the user                             12-5-84 and not a mandatory requirement.                                                     12-5-87 12-3-90 The Code Cases listed in this guide are limited to N-113-1        12-13-82    Basic Calibration Block for those cases applicable to Section XI of the Code.
Such Code Cases that were annulled on or after November 1, 1978, are listed below by number, effective dates, 7 and title.1551 N-34 11-6-72 Inservice Inspection of Welds 11-20-78 on Nuclear Components, Sec 11-20-81 tion XI OCode Case N-498 was approved for use by ASME on 5-13-91. It was included in Revision 9 of this guide because of an urgent need for the case. 7 Earlier date-date Code Case was approved by ASME; later date-date Code Case was annulled.
2-14-85      Ultrasonic Examination of All published Code Cases that are applicable to                               2-14-88      Welds 10 in. to 14 in. Thick, Section XI of the Code and were in effect on July 28,                                 12-3-90      Section XI, Division 1 1992, were reviewed for inclusion in this guide. Code N-211 4      7-13-81      Recalibration of Ultrasonic Cases that are not listed herein are either not endorsed 7-13-84      Equipment Upon Change of or will require supplementary provisions on an individ                                             Personnel, Section XI, Divi 5-7-87 ual plant basis to attain endorsement status.                                                     sion 1 4-30-90 The endorsement of a Code Case by this guide                     N-235          1-8-79      Ultrasonic Calibration Checks constitutes acceptance of its technical position for ap                             4-2-82        per Section V, Section XI, Di plications not precluded by regulatory or other require                             2-14-85      vision 1 ments or by the recommendations in this or other regu                               2-14-88 latory guides. Contingent endorsement if applicable is                               12-3-90 indicated in regulatory position I for specific cases.
Where more than two dates appear, the last date is the date that the Code Case was annulled.
However, it is the responsibility of the user to make                 N-236-1      9-5-85        Repair and Replacement of certain that no regulatory requirements are violated                               9-5-88        Class MC Vessels, Section XI, and that there are no conflicts with other recom                                     8-14-91      Division 1 mended limitations resulting from Code Case usage.                   N-307-1        12-5-84      Revised Ultrasonic Examina 12-5-87      tion Volume for Class 1 Bolt Acceptance or endorsement by the NRC staff ap                                   12-3-90      ing, Table IWB-2500-1, Ex plies only to those Code Cases or Code Case revisions                                               amination Category B-G-1, with the date of ASME approval as shown in the regu                                               When the Examinations Are latory position of this guide. Earlier or later revisions of                                       Conducted from the Center a Code Case are not endorsed by this guide. New Code                                               Drilled Hole, Section XI, Cases will require evaluation by the NRC staff to deter                                           Division 1 mine if they qualify for inclusion in the approved list.               N-311        5-11-81      Alternative Examination of Because of the continuing change in the status of Code                               4-5-84        Outlet Nozzle on Secondary Cases, it is planned that this guide will require periodic                           5-7-87        Side of Steam Generators, updating to accommodate new Code Cases and any                                       4-30-90      Section XI, Division 1 revision of existing Code Cases.
The middle date (or dates) was the date of reaffirma tion of the Code Case.1.147-4 C)1646 8-12-74 Partial Postponement of Cate N-72 11-20-78 gory B-C Examination for 1-1-81 Class 1 Components, Section XI 1647 8-12-74 Partial Postponement of Cate N-73 11-20-78 gory B-D Examination for 1-1-81 Class 1 Components, Section XI 1730 11-3-75 Acceptance Standards for N-112 7-1-79 Class 2 and 3 Components, Section XI, Division 1 1738 12-22-75 Examination
C. REGULATORY POSITION                                         Code Case N-311 is acceptable subject to the fol lowing condition in addition to those conditions
-Acceptance N-118 11-20-78 Standards for Surface Indica 1-21-82 tions in Cladding, Section XI 1-21-85 1-21-88 12-3-90 Code Case 1738 (N-118) was acceptable subject to the following condition in addition to those con ditions specified in the Code Case. The last sen tence of the "Reply" should be replaced with the following:
: 1. ACCEPTABLE CODE CASES                                                   specified in the Code Case: The applicant should indicate in the Safety Analysis Report that the The Section XI ASME Code Cases 2 listed below                         stress analysis of the nozzle inside-corner region (by number, date of ASME approval, 3 and title) are                         meets the Code Case stipulations for the state of
The provisions of this Code Case may not be applied for the examination of clad surfaces of nozzles, including the inner surface of the nozzle-to-vessel insert welds. 1804 1-14-77 Minimum Section Thickness N-167 1-14-80 Requirements for Repair of Nozzles, Section XI, Divi sion 1 N-210 3-20-78 Exemption to Hydrostatic 3-20-81 Tests After Repairs, Section XI, Division 1 Code Case N-210 was acceptable subject to the following condition in addition to those conditions specified in the Code Case. Paragraph (3) of the "Reply" should be replaced with the following:
    *Lines indicate substantive changes from Revision 10.                   stress in this region.
Re pairs to piping, pumps, and valves where the depth of the repaired cavity does not exceed 25 percent of the wall thickness.
2 A numerical listing of the Code Cases appears in the appen dix.
N-211 3-20-78 Recalibration of Ultrasonic 3-20-81 Equipment Upon Change of Personnel, Section XI, Divi sion 1 N-216 3-10-78 Alternative Rules for Reactor 7-13-81 Vessel Closure Stud Examina 7-13-84 tion, Section XI, Division 1 5-7-87 5-7-90 N-278 3-17-80 3-17-838 5-25-838 2-19-86 2-19-89 2-19-92 Alternative Ultrasonic Cali bration Block Configuration 1-3131 and T-434.3, Section XI, Division 1 Code Case N-278 is acceptable subject to the fol lowing conditions in addition to those conditions specified in the Code Case: When a universal cali bration block is used and some or all of the refer ence holes are larger than the reflector holes at comparable depths recommended by Article IV, Section V, 1980 edition of the ASME Code, a cor rection factor should be used to adjust the DAC level to compensate for the larger reflector holes. Also, if the reactor pressure vessel was previously examined by using a conventional block, a ratio between the DAC curves obtained from the two blocks should be noted (for reference) with the significant indication data. N-288 8-25-80 Hydrostatic Test Require 5-25-83 ments for Class 1 and Class 2 Components, Section XI, Di vision 1 N-306 1-15-81 Calibration Block Material 4-5-84 Selection, Appendix 1, 5-7-87 1-3121, Section XI, Division 5-7-90 N-308 9-30-81 9-30-84 9-30-87 4-30-90 9-30-90 1 Documentation of Repairs and Replacements of Compo nents in Nuclear Power Plants, Section XI, Division 1 N-234 1-8-79 1-21-82 12-5-84 12-5-87 12-3-90 Time Between Ultrasonic Calibration Checks, Section XI, Division 1 eCode Case N-278 was inadvertently allowed to expire be cause of an ASME administrative error on 3-17-83, its manda tory annulment date. The Code Case without any technical changes was reinstated on 5-25-83. Because of these circum stances, the Code Case is considered to be in effect during that period of time.1.147-5 N-252 11-19-79 Low Energy Capacitive Dis 7-16-82 charge Welding Method for Temporary or Permanent At tachments to Components and Supports, Section III, Division 1, and XI Code Case N-252 was acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant should indicate in the Safety Analysis Report the applica tion, the material, and the thickness of the mate rial to which the strain gage or thermocouple will be attached by CD welding.
4 3When more than one date is given, the earlier date is that on         The Code Case was annulled on 3-20-81 (ASME mandatory which the Code Case was approved by the ASME, and the later             annulment date). It was reinstated on 7-13-81. Because there date (or dales) is that on which the Code Case was reaffirmed by       was no change in the Code Case, the NRC considers that the the ASME.                                                               Case was in effect during the period 3-20-81 through 7-13-81.
N-343 4-2-82 2-14-85 2-14-88 12-3-90 N-375-2 4-5-84 5-7-87 5-7-90 N-406 4-5-84 5-7-87 5-7-90 N-424 7-18-85 7-18-88 Alternative Scope of Exami nation of Attachment Welds for Examination Categories B-H, B-K-i, and C-C, Section XI, Division 1 Rules for Ultrasonic Examina tion of Bolts and Studs, Sec tion XI, Division 1 Alternative Rules for Replace ment, Section XI, Division 1 Qualification of Visual Exami nation Personnel, Section XI, Division 1 N-436-1 12-7-87 Alternative 12-3-90 Evaluation of tenitic Piping, vision 1 N-444 9  12-7-87 12-3-90 N-445 5-7-87 5-7-90 Methods for Flaws in Aus Section XI, Di-Preparation of Inspection Plans, Section XI, Division 1 Use of Later Editions of SNT TC-1A for Qualification of Nondestructive Examination Personnel, Section XI, Divi sion 1, 2, and 3 N-446 5-7-87 Recertification of Visual Ex 5-7-90 amination Personnel, Section XI, Division 1 3. REVISED CODE CASES Code Cases that were endorsed by the NRC in a prior version of this guide and were superseded by revised Code Cases on or after November 1, 1978, should be considered as not endorsed as of the date of the ASME action that approved the revised version of the Code Cases. These Code Cases that are no longer endorsed are listed in the following by number, effective dates, 1 0 and title.1731 11-3-75 N-113 11-20-78 1-21-82 12-13-82 Basic Calibration Block for Ultrasonic Examination of Welds 10 in. to 13 in. Thick, Section XI, Division 1 9 Valve stroke times may be documented outside of the IST program. However, if included within the IST program and it becomes necessary to revise the maximum stroke time required by "Supplement 4-Content of IWV Valve Test Tables," it is not necessary to submit a revised IST program to the NRC solely to document a revision in valve stroke time. " 1 0 Earlier date-date Code Case was approved by ASME; later date-date revision of Code Case was approved by ASME. Where more than two dates appear, the last date is the date on which the Code Case was revised. The middle date (or dates) was the date of reaffirmation of the Code Case.N-236 1-8-79 1-21-82 12-5-84 9-5-85 Repair and Replacement of Class MC Vessels, Section XI, Division 1 Code Case N-236 was acceptable subject to the following conditions in addition to those condi tions specified in the Code Case: a. In paragraph 1.0(a), second sentence-the phrase, "while the plant is not in service," refers to a refueling outage. b. In paragraph 1.0(a), third sentence-the phrase, "the next scheduled plant outage," refers to the next scheduled refueling outage. For clarification, Repair and Replacement of Class MC Vessels means Repair and Replacement of Class MC Vessels and Components (systems).
1.147-2
Acceptance of this Code Case in no way infers NRC approval to violate the technical specification or any NRC require ments with regard to breach of containment during re*pair and replacement procedures while the plant is in operation.
 
Where a numbered Code paragraph is not identified by a particular edition of the Code, the Code in effect at the time of the ASME meeting (11-3-78) that approved the Code Case should be governing.
N-335-1      6-20-85      Rules for Ultrasonic Exami                N-416      12-5-85  Alternative Rules for Hydro 12-5-87   static Testing of Repair or Re 6-20-88      nation of Similar and Dissimi 12-3-90   placement of Class 2 Piping, 5-13-91      lar Metal Piping Welds, Sec Section XI, Division 1 tion XI, Division 1 N-419      7-18-85   Extent of VT-1 Examinations, N-355        7-16-82      Calibration Block for Angle 7-18-88  Category B-G-1 of Table 2-14-85      Beam Ultrasonic Examination 5-13-91  IWB-2500-1, Section XI, Di 2-14-88       of Large Fittings in Accor vision 1 12-3-90       dance with Appendix III N-426      7-18-85    Extent of VT-1 Examinations, 3410, Section XI, Division 1 7-18-88   Category B-G-2 of Table N-356        7-1-885      Certification Period for Level 5-13-91    IWB-2500-1, Section XI, Di 10-23-88      III NDE Personnel, Section vision 1 XI, Division 1, 2 and 3 N-427      12-5-85    Code Cases in Inspection N-389        7-25-83      Alternative Rules for Repairs, 12-5-88    Plans, Section XI, Division 1 5-14-86      Replacements, or Modifica 12-16-91 5-14-89      tions, Section XI, Division 1 I              2-5-92 Code Case N-389 is acceptable subject to the fol Code Case N-427 is acceptable subject to the fol lowing condition in addition to those conditions lowing condition in addition to those conditions                    specified in the Code Case. The sentence under specified in the Code Case: The applicant should                     (b)(1) should be replaced with the following:
N-307 1-15-81 Revised Ultrasonic Examina 4-5-84 tion Volume for Class 1 Bolt 12-5-84 ing, Examination Category B-G-1, When the Examina tions Are Conducted from the Center-Drilled Hole, Section XI, Division 1 N-335 4-2-82 Rules for Ultrasonic Examina 2-14-85 tion of Similar and Dissimilar 6-20-85 Metal Piping Welds, Section XI, Division 1 N-375 1 1  2-14-83 Rules for Ultrasonic Examina 4-14-83 tion of Bolts and Studs, Sec tion XI, Division 1 N-375-1 4-14-83 Rules for Ultrasonic Examina 4-5-84 tion of Bolts and Studs, Sec tion XI, Division 1 N-401 2-20-84 Eddy Current Examination, 2-23-87 Section XI, Division 1 5-4-88 N-402 2-20-84 2-23-87 3-5-90 3-14-91 N-408 7-12-84 5-7-87 3-8-89 Eddy Current Calibration Standard Material, Section XI, Division 1 Alternative Rules for Exami nation of Class 2 Piping, Sec tion XI, Division 1"Code Case N-375 was not listed prior to Revision 3 of this regulatory guide.1.147-6 n N-409-1 12-7-87 7-27-88 Procedure and Personnel Qualification Requirements for Ultrasonic Detection and Sizing of Flaws in Piping Welds, Section XI, Division 1 N-408-1 3-8-89 Alternative Rules for Exami 7-24-89 nation of Class 2 Piping, Sec tion XI, Division 1 Code Case N-408-1 was acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant for an operating license should define the Class 2 piping subject to volumetric and surface examination in the Preservice Inspection for determination of ac ceptability by the NRC staff. N-409 12-5-84 Procedure and Personnel 12-7-87 Qualification for Ultrasonic Detection and Sizing of Intergranular Stress Corrosion Cracking in Austenitic Piping Welds, Section XI, Division 1 Code Case N-409-1 was acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant should give prior notification to the NRC of the intention to use the Code Case. N-429 12-5-85 Alternative Rules for Ultra 2-23-87 sonic Instrument Calibration, Section XI, Division 1 N-435 5-14-86 Alternative Examination Re 7-30-86 quirements for Vessels with Wall Thickness 2 in. or Less, Section XI, Division 1 N-436 5-14-86 Alternative Methods for 12-7-87 Evaluation of Flaws in Aus tenitic Piping, Section XI, Di vision 1 N-463 11-30-88 Evaluation Procedures and 3-5-90 Acceptance Criteria for Flaws in Class 1 Ferritic Piping That Exceed the Acceptance Standards of IWB-3514.2, Section XI, Division 1 N-479 7-24-89 Boiling Water Reactor (BWR) 12-3-90 Main Steam Hydrostatic Test, Section XI, Division 1 D. IMPLEMENTATION The purpose of this section is to provide information to applicants regarding the use of this regulatory guide. 1. Except for those Code Cases that have been annulled by action of the ASME, the NRC staff has found the Code Cases listed in this regulatory guide under regulatory position C.1 acceptable for appropriate use. Other Code Cases may be considered for use in accordance with footnote 6 of the Codes and Standards rule, § 50.55a of 10 CFR Part 50. 2. Code Cases to be applied during an inspection interval or Code Cases for a preservice inspection need not be changed because a subsequent revision of the Code Case is listed as the approved version in this guide. 3. Code Cases to be applied during an inspection interval or Code Cases for a preservice inspection that were previously approved for use may continue to be used even though the Code Case has been subse quently annulled.
submit for approval the appropriate edition and                      Code Cases that were superseded with revised addenda of the Code that is to be used for the re                    Code Cases and had been approved for use in ac pair, replacement, or modification before start of                   cordance with (a) may continue to be used.
: 4. Code Cases on the approved list may be applied to procedures for an inspection interval and proce dures for the inservice inspection that were established prior to the effective date of the Code Case within the limits specified in the Code Case and applicable regula tions or recommended in other regulatory guides.1.147-7 N-485 4-30-90 Eddy Current Examination of 8-14-91 Coated Ferritic Surfaces as an Alterantive to Surface Exam ination, Section XI, Division 1 N-490 8-14-90 Alternative Vision Test 5-13-91 Requirements for Nondestruc tive Examiners, Section XI, Divisions 1, 2, and 3 N-494 12-3-90 Pipe Specific Evaluation 7-17-92 Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping that Exceeds the Acceptance Standards of 1WB-3514.2, Section XI, Division 1 4. UNACCEPTABLE CODE CASES Code Cases that are not on the approved list of this guide (paragraph C.1) or other regulatory guides, or for which authorization by the Commission has not been granted, are not acceptable on a generic basis.
the work.
APPENDIX NUMERICAL LISTING OF CODE CASES N-98 (1705-1) N-448 N-113-1 N-449 N-211 N-457 N-235 N-458 N-236-1 N-460 N-307-1 N-461 N-311 N-463-1 N-335-1 N-465 N-355 N-471 N-356 N-389 N-472 N-401-1 N-473 N-402-1 N-479-1 N-408-2 N-481 N-409-2 N-485-1 N-415 N-489 N-416 N-490-1 N-419 N-491 N-426 N-494-11 N-427 N-495 N-429-1 N-496 N-432 N-498 N-435-1 N-503 N-437 N-504 1.147-8}}
N-401-1      5-4-88        Eddy Current Examination,               N-429-1    2-23-87    Alternative Rules for Ultra 5-13-91        Section XI, Division 1                               3-5-90    sonic Instrument Calibration, N-402-1       3-14-91        Eddy      Current      Calibration                            Section XI, Division 1 Standards,        Section        XI,    N-432      2-20-86    Repair Welding Using Auto Division 1                                          2-20-89    matic    or  Machine    Gas N-408-2      7-24-89        Alternative Rules for Exami                  o        12-16-91  Tungsten-Arc          Welding nation of Class 2 Piping, Sec                                    (GTAW) Temperbead Tech tion XI, Division 1                                              nique, Section XI, Division 1 N-435-1    7-30-86    Alternative Examination Re Code Case N-408-2 is acceptable subject to the 7-30-89    quirements for Vessels with following condition in addition to those conditions Wall Thickness 2 in. or less, specified in the Code Case: The applicant for an operating license should define the Class 2 piping                                      Section XI, Division 1 subject to volumetric and surface examination in                N-437      7-30 86    Use of Digital Readout and the Preservice Inspection for determination of ac                            7-30-89    Digital Measurement Devices ceptability by the NRC staff.                                                           for Performing Pressure Tests, Section XI, Division 1 N-409-2        7-27-88      Procedure        and      Personnel      N-448      7-27-87    Qualification of VT-2 and 5-13-91        Qualification        Requirements                    4-30-90    VT-3 Visual Examination Per for Ultrasonic Detection and                                   sonnel, Section XI, Division 1 Sizing of Flaws in Piping                                      Qualification of VT-4 Visual N-449      7-27-87 Welds, Section XI, Division 1                                  Examination Personnel, Sec 4-30-90 Code Case N-409-2 is acceptable subject to the                                         tion XI, Division 1 following condition in addition to those conditions             N-457      12-7-87    Qualification Specimen Notch specified in the Code Case: The applicant should                             12-3-90    Location for Ultrasonic Ex give prior notification to the NRC of the intention                                     amination of Bolts and Studs, to use the Code Case.                                                                   Section XI, Division 1 Alternative Rules for Testing            N-458      8-14-90    Magnetic Particle Examina N-415         9-5-85 9-5-88         Pressure Relief Devices, Sec                                    tion of Coated Materials, 8-14-91       tion XI, Division 1                                             Section XI, Division 1 N-460      7-27-88    Alternative Examination Cov 5-13-91    erage for Class 1 and Class 2 Welds, Section XI, Divi 5July 1, 1988, is the date that the conditions of the Code Case sion 1 were acceptable to the NRC.
1.147-3
 
N-461      11-30-88  Alternative Rules for Piping                                    tions, Section XI, Divisions 1, 8-14-91    Calibration Block Thickness,                                    2, and 3 Section XI, Division 1                N-490-1        5-13-91   Alternative Vision Test Re Code Case N-461 is acceptable subject to the                                        quirements for Nondestructive following condition in addition to those conditions                                Examiners,         Section     XI, specified in the Code Case: Thickness measure                                      Divisions 1, 2, and 3 ments and weld joint contour of the pipe/compo          N-491          3-14-91    Alternative Rules for Exami nent must be known and used by the inspector                                        nation of Class 1, 2, 3 and who conducts the UT examination.                                                    MC Component Supports of Light-Water Cooled Power N-463-1    3-5-90    Evaluation Procedures and                                        Plants, Section XI, Division 1 Acceptance Criteria for Flaws N-494-1         7-27-92    Pipe      Specific    Evaluation in Class 1 Ferritic Piping That Procedures and Acceptance Exceed      the     Acceptance Criteria for Flaws in Class 1 Standards of IWB-3514.2,                                        Ferritic Piping that Exceeds Section XI, Division 1                                          the Acceptance Standards of N-465      11-30-88  Alternative Rules for Pump                                      IWB-3514.2,          Section XI, 8-14-91    Testing, Section XI, Divi Division 1 sion 1 N-471      4-30-90    Accoustic Emission for Suc            N-495          12-3-90    Hydrostatic Testing of Relief cessive Inspections, Section                                    Valves, Section XI, Division 1 XI, Division 1                      N-496            3-14-91    Helical Coil Threaded Inserts, Code Case N-471 is acceptable subject to the                                        Section XI, Division 1 following conditions in addition to those specified    N-498 6          5-13-91    Alternative Rules for 10-Year in the Code Case: The first successive examination                                  Hydrostatic Pressure Testing required by IWB-2420 or IWC-2420 shall be per                                      for Class 1 and 2 Systems, formed. The owner shall evaluate the results of the                                Section XI, Division 1 on-line acoustic emission monitoring to confirm        N-503            2-5-92    Limited Certification of Non that the conclusions from the acoustic emission                                    destructive Examination Per data represent the condition of the flaw indication                                sonnel, Section XI, Division 1 as estimated from the first successive ISI Examin ation and the data can be correlated with the          N-504            4-30-92    Alternative Rules for Repair of known plant operating environment.                                                  Class 1, 2, and 3 Austenitic Stainless Steel Piping, Section N-472      3-8-89    Use of Digital Readout and                                      XI, Division 1 12-16-91   Digital Measurement Devices for Performing Pump Vibra            2. ANNULLED CODE CASES tion Testing, Section XI, Divi sion 1                                     Code Cases that were endorsed by the NRC in a prior version of this guide and were later annulled by N-473      3-8-89    Alternative Rules for Valve action of the ASME should be considered as deleted 12-16-91   Testing, Section XI, Division 1 from the list of acceptable Code Cases as of the date of N-479-1    12-3-90    Boiling Water Reactor (BWR)          the ASME action that approved the annulment. Such Main      Steam      Hydrostatic    Code Cases that were annulled on or after November 7
Test, Section XI, Division 1          1, 1978, are listed below by number, effective dates, and title.
N-481      3-5-90     Alternate Examination Re quirements for Cast Austeni          1551            11-6-72    Inservice Inspection of Welds tic Pump Casings, Section XI,       N-34            11-20-78 on Nuclear Components, Sec Division 1                                            11-20-81 tion XI N-485-1    8-14-91    Eddy Current Examination of Coated Ferritic Surfaces as an          OCode Case N-498 was approved for use by ASME on 5-13-91. It was included in Revision 9 of this guide because of Alternative to Surface Exam an urgent need for the case.
ination, Section XI, Divi                7 Earlier date-date Code Case was approved by ASME; later sion 1                                date-date Code Case was annulled. Where more than two dates appear, the last date is the date that the Code Case was N-489      8-14-90    Alternative Rules for Level III      annulled. The middle date (or dates) was the date of reaffirma NDE Qualification Examina-            tion of the Code Case.
1.147-4
 
1646        8-12-74    Partial Postponement of Cate        N-252        11-19-79    Low Energy Capacitive Dis N-72          11-20-78  gory B-C Examination for                         7-16-82      charge Welding Method for 1-1-81    Class 1 Components, Section                                   Temporary or Permanent At tachments to Components and C) 1647 N-73 8-12-74 XI Partial Postponement of Cate 11-20-78 gory B-D Examination for Supports, Section III, Division 1, and XI 1-1-81    Class 1 Components, Section XI                                       Code Case N-252 was acceptable subject to the 1730          11-3-75    Acceptance      Standards for            following condition in addition to those conditions N-112        7-1-79    Class 2 and 3 Components,               specified in the Code Case: The applicant should Section XI, Division 1                   indicate in the Safety Analysis Report the applica 1738          12-22-75 Examination - Acceptance                  tion, the material, and the thickness of the mate N-118        11-20-78 Standards for Surface Indica              rial to which the strain gage or thermocouple will 1-21-82    tions in Cladding, Section XI           be attached by CD welding.
1-21-85 1-21-88                                        N-278          3-17-80    Alternative Ultrasonic Cali 12-3-90                                                      3-17-838    bration Block Configuration 5-25-838    1-3131 and T-434.3, Section 2-19-86    XI, Division 1 Code Case 1738 (N-118) was acceptable subject                          2-19-89 to the following condition in addition to those con                    2-19-92 ditions specified in the Code Case. The last sen tence of the "Reply" should be replaced with the following: The provisions of this Code Case may                Code Case N-278 is acceptable subject to the fol not be applied for the examination of clad surfaces            lowing conditions in addition to those conditions of nozzles, including the inner surface of the                specified in the Code Case: When a universal cali nozzle-to-vessel insert welds.                                bration block is used and some or all of the refer ence holes are larger than the reflector holes at 1804          1-14-77    Minimum Section Thickness                comparable depths recommended by Article IV, Requirements for Repair of               Section V, 1980 edition of the ASME Code, a cor N-167        1-14-80 Nozzles, Section XI, Divi                rection factor should be used to adjust the DAC sion 1                                   level to compensate for the larger reflector holes.
Also, if the reactor pressure vessel was previously N-210        3-20-78    Exemption      to Hydrostatic            examined by using a conventional block, a ratio 3-20-81    Tests After Repairs, Section              between the DAC curves obtained from the two XI, Division 1                            blocks should be noted (for reference) with the significant indication data.
Code Case N-210 was acceptable subject to the following condition in addition to those conditions specified in the Code Case. Paragraph (3) of the         N-288        8-25-80      Hydrostatic      Test Require "Reply" should be replaced with the following: Re                      5-25-83      ments for Class 1 and Class 2 pairs to piping, pumps, and valves where the depth                                  Components, Section XI, Di of the repaired cavity does not exceed 25 percent                                  vision 1 of the wall thickness.                                   N-306        1-15-81      Calibration Block Material 4-5-84      Selection,       Appendix          1, N-211        3-20-78    Recalibration of Ultrasonic                      5-7-87      1-3121, Section XI, Division 3-20-81    Equipment Upon Change of                          5-7-90      1 Personnel, Section XI, Divi        N-308        9-30-81      Documentation of Repairs sion 1                                            9-30-84      and Replacements of Compo N-216        3-10-78    Alternative Rules for Reactor                    9-30-87      nents    in Nuclear          Power 7-13-81    Vessel Closure Stud Examina                      4-30-90      Plants, Section XI, Division 1 7-13-84    tion, Section XI, Division 1                      9-30-90 5-7-87 5-7-90 N-234          1-8-79    Time    Between    Ultrasonic eCode Case N-278 was inadvertently allowed to expire be 1-21-82    Calibration Checks, Section         cause of an ASME administrative error on 3-17-83, its manda 12-5-84    XI, Division 1                     tory annulment date. The Code Case without any technical changes was reinstated on 5-25-83. Because of these circum 12-5-87                                        stances, the Code Case is considered to be in effect during that 12-3-90                                        period of time.
1.147-5
 
N-343          4-2-82      Alternative Scope of Exami              N-236          1-8-79    Repair and Replacement of 2-14-85     nation of Attachment Welds                              1-21-82  Class MC Vessels, Section XI, 2-14-88       for Examination Categories                            12-5-84  Division 1 12-3-90     B-H, B-K-i, and C-C, Section                          9-5-85 XI, Division 1                                Code Case N-236 was acceptable subject to the N-375-2        4-5-84        Rules for Ultrasonic Examina                following conditions in addition to those condi 5-7-87      tion of Bolts and Studs, Sec                  tions specified in the Code Case:
5-7-90      tion XI, Division 1
: a. In paragraph 1.0(a), second sentence-the N-406          4-5-84        Alternative Rules for Replace          phrase, "while the plant is not in service," refers to a 5-7-87        ment, Section XI, Division 1           refueling outage.
5-7-90 N-424          7-18-85      Qualification of Visual Exami                  b. In paragraph 1.0(a), third sentence-the 7-18-88      nation Personnel, Section XI,          phrase, "the next scheduled plant outage," refers to Division 1                              the next scheduled refueling outage.
N-436-1        12-7-87      Alternative      Methods        for          For clarification, Repair and Replacement of Class 12-3-90      Evaluation of Flaws in Aus              MC Vessels means Repair and Replacement of Class tenitic Piping, Section XI, Di-         MC Vessels and Components (systems). Acceptance vision 1                                of this Code Case in no way infers NRC approval to N-444 9        12-7-87      Preparation      of Inspection          violate the technical specification or any NRC require 12-3-90      Plans, Section XI, Division 1          ments with regard to breach of containment during re
                                                                    *pair and replacement procedures while the plant is in N-445          5-7-87      Use of Later Editions of SNT            operation.
5-7-90      TC-1A for Qualification of Nondestructive Examination                  Where a numbered Code paragraph is not Personnel, Section XI, Divi            identified by a particular edition of the Code, the Code sion 1, 2, and 3                        in effect at the time of the ASME meeting (11-3-78) that approved the Code Case should be governing.
N-446          5-7-87      Recertification of Visual Ex 5-7-90      amination Personnel, Section           N-307          1-15-81  Revised Ultrasonic Examina XI, Division 1                                        4-5-84    tion Volume for Class 1 Bolt 12-5-84  ing, Examination Category B-G-1, When the Examina
: 3. REVISED CODE CASES                                                                        tions Are Conducted from the Center-Drilled Hole, Section Code Cases that were endorsed by the NRC in a                                          XI, Division 1 prior version of this guide and were superseded by                  N-335          4-2-82    Rules for Ultrasonic Examina revised Code Cases on or after November 1, 1978,                                   2-14-85  tion of Similar and Dissimilar should be considered as not endorsed as of the date of                              6-20-85    Metal Piping Welds, Section the ASME action that approved the revised version of                                          XI, Division 1 the Code Cases. These Code Cases that are no longer                  N-375 11      2-14-83    Rules for Ultrasonic Examina endorsed are listed in the following by number,                                    4-14-83    tion of Bolts and Studs, Sec effective dates, 10 and title.                                                                tion XI, Division 1 11-3-75      Basic Calibration Block for            N-375-1       4-14-83    Rules for Ultrasonic Examina 1731 Ultrasonic Examination of                            4-5-84     tion of Bolts and Studs, Sec N-113            11-20-78 Welds 10 in. to 13 in. Thick,                                    tion XI, Division 1 1-21-82 12-13-82    Section XI, Division 1                 N-401        2-20-84    Eddy Current Examination, 2-23-87    Section XI, Division 1 5-4-88 9
N-402        2-20-84    Eddy      Current      Calibration Valve stroke times may be documented outside of the IST program. However, if included within the IST program and it 2-23-87    Standard Material, Section becomes necessary to revise the maximum stroke time required                        3-5-90    XI, Division 1 by "Supplement 4-Content of IWV Valve Test Tables," it is                          3-14-91 not necessary to submit a revised IST program to the NRC solely to document a revision in valve stroke time.                         N-408        7-12-84    Alternative Rules for Exami
    " Earlier date-date Code Case was approved by ASME; 10                                                                              5-7-87    nation of Class 2 Piping, Sec later date-date revision of Code Case was approved by ASME.                        3-8-89    tion XI, Division 1 Where more than two dates appear, the last date is the date on which the Code Case was revised. The middle date (or dates)            "Code Case N-375 was not listed prior to Revision 3 of this was the date of reaffirmation of the Code Case.                      regulatory guide.
1.147-6
 
N-408-1      3-8-89      Alternative Rules for Exami          N-485        4-30-90      Eddy Current Examination of 7-24-89      nation of Class 2 Piping, Sec                      8-14-91    Coated Ferritic Surfaces as an tion XI, Division 1                                             Alterantive to Surface Exam n    Code Case N-408-1 was acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant for an N-490          8-14-90 5-13-91 ination, Section XI, Division 1 Alternative     Vision Requirements for Nondestruc Test tive Examiners, Section XI, operating license should define the Class 2 piping                                    Divisions 1, 2, and 3 subject to volumetric and surface examination in the Preservice Inspection for determination of ac          N-494        12-3-90    Pipe    Specific    Evaluation ceptability by the NRC staff.                                            7-17-92    Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping that Exceeds N-409        12-5-84      Procedure      and Personnel                                  the Acceptance Standards of 12-7-87     Qualification for Ultrasonic                                    1WB-3514.2,      Section XI, Detection and Sizing of                                         Division 1 Intergranular Stress Corrosion Cracking in Austenitic Piping Welds, Section XI, Division 1         4. UNACCEPTABLE CODE CASES N-409-1      12-7-87     Procedure      and    Personnel           Code Cases that are not on the approved list of this 7-27-88      Qualification Requirements for        guide (paragraph C.1) or other regulatory guides, or Ultrasonic      Detection    and     for which authorization by the Commission has not Sizing of Flaws in Piping            been granted, are not acceptable on a generic basis.
Welds, Section XI, Division 1 Code Case N-409-1 was acceptable subject to the                            D. IMPLEMENTATION following condition in addition to those conditions            The purpose of this section is to provide specified in the Code Case: The applicant should            information to applicants regarding the use of this give prior notification to the NRC of the intention        regulatory guide.
to use the Code Case.
: 1. Except for those Code Cases that have been annulled by action of the ASME, the NRC staff has N-429        12-5-85      Alternative Rules for Ultra          found the Code Cases listed in this regulatory guide 2-23-87      sonic Instrument Calibration,       under regulatory position C.1 acceptable for Section XI, Division 1              appropriate use. Other Code Cases may be considered N-435        5-14-86      Alternative Examination Re          for use in accordance with footnote 6 of the Codes and 7-30-86      quirements for Vessels with          Standards rule, § 50.55a of 10 CFR Part 50.
Wall Thickness 2 in. or Less,              2. Code Cases to be applied during an inspection Section XI, Division 1               interval or Code Cases for a preservice inspection need not be changed because a subsequent revision of the N-436        5-14-86      Alternative      Methods    for Code Case is listed as the approved version in this 12-7-87      Evaluation of Flaws in Aus          guide.
tenitic Piping, Section XI, Di vision 1                                   3. Code Cases to be applied during an inspection interval or Code Cases for a preservice inspection that N-463        11-30-88    Evaluation Procedures and            were previously approved for use may continue to be 3-5-90      Acceptance Criteria for Flaws        used even though the Code Case has been subse in Class 1 Ferritic Piping That      quently annulled.
Exceed      the    Acceptance
: 4. Code Cases on the approved list may be applied Standards of IWB-3514.2, to procedures for an inspection interval and proce Section XI, Division 1 dures for the inservice inspection that were established N-479        7-24-89      Boiling Water Reactor (BWR)          prior to the effective date of the Code Case within the 12-3-90      Main Steam Hydrostatic Test,         limits specified in the Code Case and applicable regula Section XI, Division 1               tions or recommended in other regulatory guides.
1.147-7
 
APPENDIX NUMERICAL LISTING OF CODE CASES N-98 (1705-1)             N-448 N-113-1                   N-449 N-211                     N-457 N-235                     N-458 N-236-1                 N-460 N-307-1                 N-461 N-311                   N-463-1 N-335-1                 N-465 N-355 N-471 N-356 N-389                   N-472 N-401-1                 N-473 N-402-1                   N-479-1 N-408-2                   N-481 N-409-2                   N-485-1 N-415                     N-489 N-416                   N-490-1 N-419                   N-491 N-426                   N-494-11 N-427                   N-495 N-429-1                 N-496 N-432                   N-498 N-435-1                 N-503 N-437                   N-504 1.147-8}}

Latest revision as of 05:00, 24 November 2019

1 to Regulatory Guide 1. 147, Inservice Inspection Code Case Acceptability ASME Section XI Division 1.
ML030230238
Person / Time
Issue date: 10/31/1994
From:
Office of Nuclear Regulatory Research
To:
References
RG-1.147, Rev 11
Download: ML030230238 (8)


Text

U.S. NUCLEAR REGULATORY COMMISSION Revision 11 October 1994 C-') REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.147 INSERVICE INSPECTION CODE CASE ACCEPTABILITY ASME SECTION XI DIVISION 1 A. INTRODUCTION General Design Criterion 1, "Quality Standards and Records," of Appendix A, "General Design Section 50.55a, "Codes and Standards," of Criteria for Nuclear Power Plants," to 10 CFR Part 50 10 CFR Part 50, "Domestic Licensing of Production requires, in part, that structures, systems, and compo and Utilization Facilities," requires, in part, that each nents important to safety be designed, fabricated, operating license for a boiling or pressurized water erected, and tested to quality standards commensurate cooled nuclear power facility and each construction with the importance of the safety function to be per permit for a utilization facility be subject to the condi formed. Where generally recognized codes and stan tions in paragraph (g), "Inservice Inspection Require dards are used, Criterion 1 requires that they be identi ments," of § 50.55a. Paragraph (g) requires, in part, fied and evaluated to determine their applicability, that Classes 1, 2, and 3 components and their supports adequacy, and sufficiency and be supplemented or meet the requirements of Section XI, "Rules for Inser modified as necessary to ensure a quality product in vice Inspection of Nuclear Power Plant Compo keeping with the required safety function.

nents,"' of the American Society of Mechanical Engi This regulatory guide lists those Section XI ASME neers (ASME) Boiler and Pressure Vessel Code or Code Cases that are generally acceptable to the NRC equivalent quality standards. Paragraph 50.55a(b), in staff for implementation in the inservice inspection of part, references the latest editions and addenda in ef light-water-cooled nuclear power plants.

fect of Section XI of the Code and any supplementary This regulatory guide contains no information col requirements to that section of the Code. Footnote 6 lection activities and, therefore, is not subject to the to § 50.55a states that the use of specific Code Cases requirements of the Paperwork Reduction Act of 1980 may be authorized by the Commission upon request (44 U.S.C. 3501 et seq.).

pursuant to paragraph 50.55a(a)(3), which requires that proposed alternatives to the described require B. DISCUSSION ments or portions thereof provide an acceptable level of quality and safety. The ASME Boiler and Pressure Vessel Committee 1

publishes a document entitled "Code Cases." Gener ally, the individual Code Cases that make up this docu

'Copies may be obtained from the American Society of Me ment explain the intent of Code rules or provide for chanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017. alternative requirements under special circumstances.

The guides are Issued In the following ten broad divisions:

USNRC REGULATORY GUIDES Regulatory Guides are Issued to describe and make available to the public such Information as methods acceptable to the NRC staff for Implement 1. Power Reactors 6. Products

7. Transportation Ing specific parts of the Commission's regulations, techniques used by 2. Research and Test Reactors
8. Occupational Health the staff In evaluating specific problems or postulated accidents, and 3. Fuels and Materials Facilities Environmental and Siting g. Antitrust and Financial Review data needed by the NRC staff In Its review of applications for permits and 4.

10 General licenses. Regulatory Guides are not substitutes for regulations, and com 5. Materials and Plant Protection pliance with them Is not required Methods and solutions different from those set out In the guides will be acceptable If they provide a basis for the Copies of Issued guides may be purchased from the Government Printing findings requisite to the Issuance or continuance of a permit or license by the Commission Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of Documents, U.S.

This guide was Issued after consideration of comments received from the Government Printing Office, Mali Stop SSOP, Washington, DC public. Comments and suggestions for Improvements In these guides are 20402-9328, telephone (202)512-2249 or (202)512-2171.

encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new Information or experience.

Issued guides may also be purchased from the National Technical Infor Written comments may be submitted to the Rules Review and Directives mation Service on a standing order basis. Details on this service may be Branch, DFIPS, ADM, U.S. Nuclear Regulatory Commission, Washing obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161.

ton, DC 20555-0001.

Most Code Cases are eventually superseded by acceptable to the NRC staff for application in the inser revision of the Code and then are annulled by action of vice inspection of components and their supports for the ASME. In such instances, the intent of the an water-cooled nuclear power plants. Their use is accept nulled Code Case becomes part of the revised Code, able within the limitations stated in the "Inquiry" and and therefore continued use of the Code Case intent is "Reply" sections of each individual Code Case, within sanctioned under the rules of the Code. In other in the limitations of such NRC or other requirements as stances, the Code Case is annulled because it is no may exist, and within the additional limitations recom longer acceptable or there is no further requirement mended by the NRC staff and given with the individual for it. A Code Case that was approved for a particular Code Case in the list.

situation and not for a generic application should be used only for the approved situation because annul 1705-1 3-1-76 Ultrasonic Examination ment of such a Code Case could result in situations that N-98 11-20-78 Calibration Block Tolerances, would not meet Code requirements. The ASME con 1-21-82 Section XI siders the use of Code Cases to be optional for the user 12-5-84 and not a mandatory requirement. 12-5-87 12-3-90 The Code Cases listed in this guide are limited to N-113-1 12-13-82 Basic Calibration Block for those cases applicable to Section XI of the Code.

2-14-85 Ultrasonic Examination of All published Code Cases that are applicable to 2-14-88 Welds 10 in. to 14 in. Thick,Section XI of the Code and were in effect on July 28, 12-3-90 Section XI, Division 1 1992, were reviewed for inclusion in this guide. Code N-211 4 7-13-81 Recalibration of Ultrasonic Cases that are not listed herein are either not endorsed 7-13-84 Equipment Upon Change of or will require supplementary provisions on an individ Personnel,Section XI, Divi 5-7-87 ual plant basis to attain endorsement status. sion 1 4-30-90 The endorsement of a Code Case by this guide N-235 1-8-79 Ultrasonic Calibration Checks constitutes acceptance of its technical position for ap 4-2-82 per Section V,Section XI, Di plications not precluded by regulatory or other require 2-14-85 vision 1 ments or by the recommendations in this or other regu 2-14-88 latory guides. Contingent endorsement if applicable is 12-3-90 indicated in regulatory position I for specific cases.

However, it is the responsibility of the user to make N-236-1 9-5-85 Repair and Replacement of certain that no regulatory requirements are violated 9-5-88 Class MC Vessels,Section XI, and that there are no conflicts with other recom 8-14-91 Division 1 mended limitations resulting from Code Case usage. N-307-1 12-5-84 Revised Ultrasonic Examina 12-5-87 tion Volume for Class 1 Bolt Acceptance or endorsement by the NRC staff ap 12-3-90 ing, Table IWB-2500-1, Ex plies only to those Code Cases or Code Case revisions amination Category B-G-1, with the date of ASME approval as shown in the regu When the Examinations Are latory position of this guide. Earlier or later revisions of Conducted from the Center a Code Case are not endorsed by this guide. New Code Drilled Hole,Section XI, Cases will require evaluation by the NRC staff to deter Division 1 mine if they qualify for inclusion in the approved list. N-311 5-11-81 Alternative Examination of Because of the continuing change in the status of Code 4-5-84 Outlet Nozzle on Secondary Cases, it is planned that this guide will require periodic 5-7-87 Side of Steam Generators, updating to accommodate new Code Cases and any 4-30-90 Section XI, Division 1 revision of existing Code Cases.

C. REGULATORY POSITION Code Case N-311 is acceptable subject to the fol lowing condition in addition to those conditions

1. ACCEPTABLE CODE CASES specified in the Code Case: The applicant should indicate in the Safety Analysis Report that the The Section XI ASME Code Cases 2 listed below stress analysis of the nozzle inside-corner region (by number, date of ASME approval, 3 and title) are meets the Code Case stipulations for the state of
  • Lines indicate substantive changes from Revision 10. stress in this region.

2 A numerical listing of the Code Cases appears in the appen dix.

4 3When more than one date is given, the earlier date is that on The Code Case was annulled on 3-20-81 (ASME mandatory which the Code Case was approved by the ASME, and the later annulment date). It was reinstated on 7-13-81. Because there date (or dales) is that on which the Code Case was reaffirmed by was no change in the Code Case, the NRC considers that the the ASME. Case was in effect during the period 3-20-81 through 7-13-81.

1.147-2

N-335-1 6-20-85 Rules for Ultrasonic Exami N-416 12-5-85 Alternative Rules for Hydro 12-5-87 static Testing of Repair or Re 6-20-88 nation of Similar and Dissimi 12-3-90 placement of Class 2 Piping, 5-13-91 lar Metal Piping Welds, Sec Section XI, Division 1 tion XI, Division 1 N-419 7-18-85 Extent of VT-1 Examinations, N-355 7-16-82 Calibration Block for Angle 7-18-88 Category B-G-1 of Table 2-14-85 Beam Ultrasonic Examination 5-13-91 IWB-2500-1,Section XI, Di 2-14-88 of Large Fittings in Accor vision 1 12-3-90 dance with Appendix III N-426 7-18-85 Extent of VT-1 Examinations, 3410,Section XI, Division 1 7-18-88 Category B-G-2 of Table N-356 7-1-885 Certification Period for Level 5-13-91 IWB-2500-1,Section XI, Di 10-23-88 III NDE Personnel, Section vision 1 XI, Division 1, 2 and 3 N-427 12-5-85 Code Cases in Inspection N-389 7-25-83 Alternative Rules for Repairs, 12-5-88 Plans,Section XI, Division 1 5-14-86 Replacements, or Modifica 12-16-91 5-14-89 tions,Section XI, Division 1 I 2-5-92 Code Case N-389 is acceptable subject to the fol Code Case N-427 is acceptable subject to the fol lowing condition in addition to those conditions lowing condition in addition to those conditions specified in the Code Case. The sentence under specified in the Code Case: The applicant should (b)(1) should be replaced with the following:

submit for approval the appropriate edition and Code Cases that were superseded with revised addenda of the Code that is to be used for the re Code Cases and had been approved for use in ac pair, replacement, or modification before start of cordance with (a) may continue to be used.

the work.

N-401-1 5-4-88 Eddy Current Examination, N-429-1 2-23-87 Alternative Rules for Ultra 5-13-91 Section XI, Division 1 3-5-90 sonic Instrument Calibration, N-402-1 3-14-91 Eddy Current Calibration Section XI, Division 1 Standards, Section XI, N-432 2-20-86 Repair Welding Using Auto Division 1 2-20-89 matic or Machine Gas N-408-2 7-24-89 Alternative Rules for Exami o 12-16-91 Tungsten-Arc Welding nation of Class 2 Piping, Sec (GTAW) Temperbead Tech tion XI, Division 1 nique,Section XI, Division 1 N-435-1 7-30-86 Alternative Examination Re Code Case N-408-2 is acceptable subject to the 7-30-89 quirements for Vessels with following condition in addition to those conditions Wall Thickness 2 in. or less, specified in the Code Case: The applicant for an operating license should define the Class 2 piping Section XI, Division 1 subject to volumetric and surface examination in N-437 7-30 86 Use of Digital Readout and the Preservice Inspection for determination of ac 7-30-89 Digital Measurement Devices ceptability by the NRC staff. for Performing Pressure Tests,Section XI, Division 1 N-409-2 7-27-88 Procedure and Personnel N-448 7-27-87 Qualification of VT-2 and 5-13-91 Qualification Requirements 4-30-90 VT-3 Visual Examination Per for Ultrasonic Detection and sonnel,Section XI, Division 1 Sizing of Flaws in Piping Qualification of VT-4 Visual N-449 7-27-87 Welds,Section XI, Division 1 Examination Personnel, Sec 4-30-90 Code Case N-409-2 is acceptable subject to the tion XI, Division 1 following condition in addition to those conditions N-457 12-7-87 Qualification Specimen Notch specified in the Code Case: The applicant should 12-3-90 Location for Ultrasonic Ex give prior notification to the NRC of the intention amination of Bolts and Studs, to use the Code Case. Section XI, Division 1 Alternative Rules for Testing N-458 8-14-90 Magnetic Particle Examina N-415 9-5-85 9-5-88 Pressure Relief Devices, Sec tion of Coated Materials, 8-14-91 tion XI, Division 1 Section XI, Division 1 N-460 7-27-88 Alternative Examination Cov 5-13-91 erage for Class 1 and Class 2 Welds,Section XI, Divi 5July 1, 1988, is the date that the conditions of the Code Case sion 1 were acceptable to the NRC.

1.147-3

N-461 11-30-88 Alternative Rules for Piping tions,Section XI, Divisions 1, 8-14-91 Calibration Block Thickness, 2, and 3 Section XI, Division 1 N-490-1 5-13-91 Alternative Vision Test Re Code Case N-461 is acceptable subject to the quirements for Nondestructive following condition in addition to those conditions Examiners, Section XI, specified in the Code Case: Thickness measure Divisions 1, 2, and 3 ments and weld joint contour of the pipe/compo N-491 3-14-91 Alternative Rules for Exami nent must be known and used by the inspector nation of Class 1, 2, 3 and who conducts the UT examination. MC Component Supports of Light-Water Cooled Power N-463-1 3-5-90 Evaluation Procedures and Plants,Section XI, Division 1 Acceptance Criteria for Flaws N-494-1 7-27-92 Pipe Specific Evaluation in Class 1 Ferritic Piping That Procedures and Acceptance Exceed the Acceptance Criteria for Flaws in Class 1 Standards of IWB-3514.2, Ferritic Piping that ExceedsSection XI, Division 1 the Acceptance Standards of N-465 11-30-88 Alternative Rules for Pump IWB-3514.2, Section XI, 8-14-91 Testing,Section XI, Divi Division 1 sion 1 N-471 4-30-90 Accoustic Emission for Suc N-495 12-3-90 Hydrostatic Testing of Relief cessive Inspections, Section Valves,Section XI, Division 1 XI, Division 1 N-496 3-14-91 Helical Coil Threaded Inserts, Code Case N-471 is acceptable subject to the Section XI, Division 1 following conditions in addition to those specified N-498 6 5-13-91 Alternative Rules for 10-Year in the Code Case: The first successive examination Hydrostatic Pressure Testing required by IWB-2420 or IWC-2420 shall be per for Class 1 and 2 Systems, formed. The owner shall evaluate the results of the Section XI, Division 1 on-line acoustic emission monitoring to confirm N-503 2-5-92 Limited Certification of Non that the conclusions from the acoustic emission destructive Examination Per data represent the condition of the flaw indication sonnel,Section XI, Division 1 as estimated from the first successive ISI Examin ation and the data can be correlated with the N-504 4-30-92 Alternative Rules for Repair of known plant operating environment. Class 1, 2, and 3 Austenitic Stainless Steel Piping, Section N-472 3-8-89 Use of Digital Readout and XI, Division 1 12-16-91 Digital Measurement Devices for Performing Pump Vibra 2. ANNULLED CODE CASES tion Testing,Section XI, Divi sion 1 Code Cases that were endorsed by the NRC in a prior version of this guide and were later annulled by N-473 3-8-89 Alternative Rules for Valve action of the ASME should be considered as deleted 12-16-91 Testing,Section XI, Division 1 from the list of acceptable Code Cases as of the date of N-479-1 12-3-90 Boiling Water Reactor (BWR) the ASME action that approved the annulment. Such Main Steam Hydrostatic Code Cases that were annulled on or after November 7

Test,Section XI, Division 1 1, 1978, are listed below by number, effective dates, and title.

N-481 3-5-90 Alternate Examination Re quirements for Cast Austeni 1551 11-6-72 Inservice Inspection of Welds tic Pump Casings,Section XI, N-34 11-20-78 on Nuclear Components, Sec Division 1 11-20-81 tion XI N-485-1 8-14-91 Eddy Current Examination of Coated Ferritic Surfaces as an OCode Case N-498 was approved for use by ASME on 5-13-91. It was included in Revision 9 of this guide because of Alternative to Surface Exam an urgent need for the case.

ination,Section XI, Divi 7 Earlier date-date Code Case was approved by ASME; later sion 1 date-date Code Case was annulled. Where more than two dates appear, the last date is the date that the Code Case was N-489 8-14-90 Alternative Rules for Level III annulled. The middle date (or dates) was the date of reaffirma NDE Qualification Examina- tion of the Code Case.

1.147-4

1646 8-12-74 Partial Postponement of Cate N-252 11-19-79 Low Energy Capacitive Dis N-72 11-20-78 gory B-C Examination for 7-16-82 charge Welding Method for 1-1-81 Class 1 Components, Section Temporary or Permanent At tachments to Components and C) 1647 N-73 8-12-74 XI Partial Postponement of Cate 11-20-78 gory B-D Examination for Supports,Section III, Division 1, and XI 1-1-81 Class 1 Components,Section XI Code Case N-252 was acceptable subject to the 1730 11-3-75 Acceptance Standards for following condition in addition to those conditions N-112 7-1-79 Class 2 and 3 Components, specified in the Code Case: The applicant should Section XI, Division 1 indicate in the Safety Analysis Report the applica 1738 12-22-75 Examination - Acceptance tion, the material, and the thickness of the mate N-118 11-20-78 Standards for Surface Indica rial to which the strain gage or thermocouple will 1-21-82 tions in Cladding,Section XI be attached by CD welding.

1-21-85 1-21-88 N-278 3-17-80 Alternative Ultrasonic Cali 12-3-90 3-17-838 bration Block Configuration 5-25-838 1-3131 and T-434.3, Section 2-19-86 XI, Division 1 Code Case 1738 (N-118) was acceptable subject 2-19-89 to the following condition in addition to those con 2-19-92 ditions specified in the Code Case. The last sen tence of the "Reply" should be replaced with the following: The provisions of this Code Case may Code Case N-278 is acceptable subject to the fol not be applied for the examination of clad surfaces lowing conditions in addition to those conditions of nozzles, including the inner surface of the specified in the Code Case: When a universal cali nozzle-to-vessel insert welds. bration block is used and some or all of the refer ence holes are larger than the reflector holes at 1804 1-14-77 Minimum Section Thickness comparable depths recommended by Article IV, Requirements for Repair of Section V, 1980 edition of the ASME Code, a cor N-167 1-14-80 Nozzles,Section XI, Divi rection factor should be used to adjust the DAC sion 1 level to compensate for the larger reflector holes.

Also, if the reactor pressure vessel was previously N-210 3-20-78 Exemption to Hydrostatic examined by using a conventional block, a ratio 3-20-81 Tests After Repairs, Section between the DAC curves obtained from the two XI, Division 1 blocks should be noted (for reference) with the significant indication data.

Code Case N-210 was acceptable subject to the following condition in addition to those conditions specified in the Code Case. Paragraph (3) of the N-288 8-25-80 Hydrostatic Test Require "Reply" should be replaced with the following: Re 5-25-83 ments for Class 1 and Class 2 pairs to piping, pumps, and valves where the depth Components,Section XI, Di of the repaired cavity does not exceed 25 percent vision 1 of the wall thickness. N-306 1-15-81 Calibration Block Material 4-5-84 Selection, Appendix 1, N-211 3-20-78 Recalibration of Ultrasonic 5-7-87 1-3121,Section XI, Division 3-20-81 Equipment Upon Change of 5-7-90 1 Personnel,Section XI, Divi N-308 9-30-81 Documentation of Repairs sion 1 9-30-84 and Replacements of Compo N-216 3-10-78 Alternative Rules for Reactor 9-30-87 nents in Nuclear Power 7-13-81 Vessel Closure Stud Examina 4-30-90 Plants,Section XI, Division 1 7-13-84 tion,Section XI, Division 1 9-30-90 5-7-87 5-7-90 N-234 1-8-79 Time Between Ultrasonic eCode Case N-278 was inadvertently allowed to expire be 1-21-82 Calibration Checks, Section cause of an ASME administrative error on 3-17-83, its manda 12-5-84 XI, Division 1 tory annulment date. The Code Case without any technical changes was reinstated on 5-25-83. Because of these circum 12-5-87 stances, the Code Case is considered to be in effect during that 12-3-90 period of time.

1.147-5

N-343 4-2-82 Alternative Scope of Exami N-236 1-8-79 Repair and Replacement of 2-14-85 nation of Attachment Welds 1-21-82 Class MC Vessels,Section XI, 2-14-88 for Examination Categories 12-5-84 Division 1 12-3-90 B-H, B-K-i, and C-C, Section 9-5-85 XI, Division 1 Code Case N-236 was acceptable subject to the N-375-2 4-5-84 Rules for Ultrasonic Examina following conditions in addition to those condi 5-7-87 tion of Bolts and Studs, Sec tions specified in the Code Case:

5-7-90 tion XI, Division 1

a. In paragraph 1.0(a), second sentence-the N-406 4-5-84 Alternative Rules for Replace phrase, "while the plant is not in service," refers to a 5-7-87 ment,Section XI, Division 1 refueling outage.

5-7-90 N-424 7-18-85 Qualification of Visual Exami b. In paragraph 1.0(a), third sentence-the 7-18-88 nation Personnel,Section XI, phrase, "the next scheduled plant outage," refers to Division 1 the next scheduled refueling outage.

N-436-1 12-7-87 Alternative Methods for For clarification, Repair and Replacement of Class 12-3-90 Evaluation of Flaws in Aus MC Vessels means Repair and Replacement of Class tenitic Piping,Section XI, Di- MC Vessels and Components (systems). Acceptance vision 1 of this Code Case in no way infers NRC approval to N-444 9 12-7-87 Preparation of Inspection violate the technical specification or any NRC require 12-3-90 Plans,Section XI, Division 1 ments with regard to breach of containment during re

  • pair and replacement procedures while the plant is in N-445 5-7-87 Use of Later Editions of SNT operation.

5-7-90 TC-1A for Qualification of Nondestructive Examination Where a numbered Code paragraph is not Personnel,Section XI, Divi identified by a particular edition of the Code, the Code sion 1, 2, and 3 in effect at the time of the ASME meeting (11-3-78) that approved the Code Case should be governing.

N-446 5-7-87 Recertification of Visual Ex 5-7-90 amination Personnel, Section N-307 1-15-81 Revised Ultrasonic Examina XI, Division 1 4-5-84 tion Volume for Class 1 Bolt 12-5-84 ing, Examination Category B-G-1, When the Examina

3. REVISED CODE CASES tions Are Conducted from the Center-Drilled Hole, Section Code Cases that were endorsed by the NRC in a XI, Division 1 prior version of this guide and were superseded by N-335 4-2-82 Rules for Ultrasonic Examina revised Code Cases on or after November 1, 1978, 2-14-85 tion of Similar and Dissimilar should be considered as not endorsed as of the date of 6-20-85 Metal Piping Welds, Section the ASME action that approved the revised version of XI, Division 1 the Code Cases. These Code Cases that are no longer N-375 11 2-14-83 Rules for Ultrasonic Examina endorsed are listed in the following by number, 4-14-83 tion of Bolts and Studs, Sec effective dates, 10 and title. tion XI, Division 1 11-3-75 Basic Calibration Block for N-375-1 4-14-83 Rules for Ultrasonic Examina 1731 Ultrasonic Examination of 4-5-84 tion of Bolts and Studs, Sec N-113 11-20-78 Welds 10 in. to 13 in. Thick, tion XI, Division 1 1-21-82 12-13-82 Section XI, Division 1 N-401 2-20-84 Eddy Current Examination, 2-23-87 Section XI, Division 1 5-4-88 9

N-402 2-20-84 Eddy Current Calibration Valve stroke times may be documented outside of the IST program. However, if included within the IST program and it 2-23-87 Standard Material, Section becomes necessary to revise the maximum stroke time required 3-5-90 XI, Division 1 by "Supplement 4-Content of IWV Valve Test Tables," it is 3-14-91 not necessary to submit a revised IST program to the NRC solely to document a revision in valve stroke time. N-408 7-12-84 Alternative Rules for Exami

" Earlier date-date Code Case was approved by ASME; 10 5-7-87 nation of Class 2 Piping, Sec later date-date revision of Code Case was approved by ASME. 3-8-89 tion XI, Division 1 Where more than two dates appear, the last date is the date on which the Code Case was revised. The middle date (or dates) "Code Case N-375 was not listed prior to Revision 3 of this was the date of reaffirmation of the Code Case. regulatory guide.

1.147-6

N-408-1 3-8-89 Alternative Rules for Exami N-485 4-30-90 Eddy Current Examination of 7-24-89 nation of Class 2 Piping, Sec 8-14-91 Coated Ferritic Surfaces as an tion XI, Division 1 Alterantive to Surface Exam n Code Case N-408-1 was acceptable subject to the following condition in addition to those conditions specified in the Code Case: The applicant for an N-490 8-14-90 5-13-91 ination,Section XI, Division 1 Alternative Vision Requirements for Nondestruc Test tive Examiners,Section XI, operating license should define the Class 2 piping Divisions 1, 2, and 3 subject to volumetric and surface examination in the Preservice Inspection for determination of ac N-494 12-3-90 Pipe Specific Evaluation ceptability by the NRC staff. 7-17-92 Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping that Exceeds N-409 12-5-84 Procedure and Personnel the Acceptance Standards of 12-7-87 Qualification for Ultrasonic 1WB-3514.2, Section XI, Detection and Sizing of Division 1 Intergranular Stress Corrosion Cracking in Austenitic Piping Welds,Section XI, Division 1 4. UNACCEPTABLE CODE CASES N-409-1 12-7-87 Procedure and Personnel Code Cases that are not on the approved list of this 7-27-88 Qualification Requirements for guide (paragraph C.1) or other regulatory guides, or Ultrasonic Detection and for which authorization by the Commission has not Sizing of Flaws in Piping been granted, are not acceptable on a generic basis.

Welds,Section XI, Division 1 Code Case N-409-1 was acceptable subject to the D. IMPLEMENTATION following condition in addition to those conditions The purpose of this section is to provide specified in the Code Case: The applicant should information to applicants regarding the use of this give prior notification to the NRC of the intention regulatory guide.

to use the Code Case.

1. Except for those Code Cases that have been annulled by action of the ASME, the NRC staff has N-429 12-5-85 Alternative Rules for Ultra found the Code Cases listed in this regulatory guide 2-23-87 sonic Instrument Calibration, under regulatory position C.1 acceptable for Section XI, Division 1 appropriate use. Other Code Cases may be considered N-435 5-14-86 Alternative Examination Re for use in accordance with footnote 6 of the Codes and 7-30-86 quirements for Vessels with Standards rule, § 50.55a of 10 CFR Part 50.

Wall Thickness 2 in. or Less, 2. Code Cases to be applied during an inspection Section XI, Division 1 interval or Code Cases for a preservice inspection need not be changed because a subsequent revision of the N-436 5-14-86 Alternative Methods for Code Case is listed as the approved version in this 12-7-87 Evaluation of Flaws in Aus guide.

tenitic Piping,Section XI, Di vision 1 3. Code Cases to be applied during an inspection interval or Code Cases for a preservice inspection that N-463 11-30-88 Evaluation Procedures and were previously approved for use may continue to be 3-5-90 Acceptance Criteria for Flaws used even though the Code Case has been subse in Class 1 Ferritic Piping That quently annulled.

Exceed the Acceptance

4. Code Cases on the approved list may be applied Standards of IWB-3514.2, to procedures for an inspection interval and proce Section XI, Division 1 dures for the inservice inspection that were established N-479 7-24-89 Boiling Water Reactor (BWR) prior to the effective date of the Code Case within the 12-3-90 Main Steam Hydrostatic Test, limits specified in the Code Case and applicable regula Section XI, Division 1 tions or recommended in other regulatory guides.

1.147-7

APPENDIX NUMERICAL LISTING OF CODE CASES N-98 (1705-1) N-448 N-113-1 N-449 N-211 N-457 N-235 N-458 N-236-1 N-460 N-307-1 N-461 N-311 N-463-1 N-335-1 N-465 N-355 N-471 N-356 N-389 N-472 N-401-1 N-473 N-402-1 N-479-1 N-408-2 N-481 N-409-2 N-485-1 N-415 N-489 N-416 N-490-1 N-419 N-491 N-426 N-494-11 N-427 N-495 N-429-1 N-496 N-432 N-498 N-435-1 N-503 N-437 N-504 1.147-8