| title = Unit 2 Pressurizer Safety Valve Low Lift Setting
| title = Unit 2 Pressurizer Safety Valve LOW Lift Setting
| docket = 05000317, 05000318
| docket = 05000317, 05000318
| inspection report = IR 05000317/2007004
| inspection report = IR 05000317/2007004
Line 12: Line 12:
| identified by = NRC
| identified by = NRC
| Inspection procedure = IP 71152
| Inspection procedure = IP 71152
| Inspector = S Kennedy, M Klump, R Rolph, D Schroeder, M Davis, M Patel, J Kraftya, Dimitriadis G, Dentel G, Johnson M, Davis P, Frechette P, Presby R, Rolph S, Kenned
| Inspector = S Kennedy, M Klump, R Rolph, D Schroeder, M Davis, M Patel, J Kraftya, Dimitriadisg Dentel, G Johnson, M Davis, P Frechette, P Presby, R Rolph, S Kennedy
| CCA = N/A for ROP
| CCA = N/A for ROP
| INPO aspect =  
| INPO aspect =  

Latest revision as of 20:32, 20 February 2018

04
Site: Calvert Cliffs Constellation icon.png
Report IR 05000317/2007004 Section 4OA2
Date counted Sep 30, 2007 (2007Q3)
Type: URI:
cornerstone Initiating Events
Identified by: NRC identified
Inspection Procedure: IP 71152
Inspectors (proximate) S Kennedy
M Klump
R Rolph
D Schroeder
M Davis
M Patel
J Kraftya
Dimitriadisg Dentel
G Johnson
M Davis
P Frechette
P Presby
R Rolph
S Kennedy
INPO aspect
'