ML17125A247: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
| issue date = 07/20/2017 | | issue date = 07/20/2017 | ||
| title = OEDO-17-00104 - FRN for Barry Quigley, Citizen, E-mail 2.206 Petition for Byron and Braidwood Units 1 & 2 High Energy Line Break | | title = OEDO-17-00104 - FRN for Barry Quigley, Citizen, E-mail 2.206 Petition for Byron and Braidwood Units 1 & 2 High Energy Line Break | ||
| author name = Holian B | | author name = Holian B | ||
| author affiliation = NRC/NRR | | author affiliation = NRC/NRR | ||
| addressee name = | | addressee name = | ||
Line 9: | Line 9: | ||
| docket = 05000454, 05000455, 05000456, 05000457 | | docket = 05000454, 05000455, 05000456, 05000457 | ||
| license number = NPF-037, NPF-066, NPF-072, NPF-077 | | license number = NPF-037, NPF-066, NPF-072, NPF-077 | ||
| contact person = Wiebe J | | contact person = Wiebe J | ||
| case reference number = 0EDO-17-00104, CAC TM3111, NRC-2017-0167 | | case reference number = 0EDO-17-00104, CAC TM3111, NRC-2017-0167 | ||
| package number = ML14070299 | | package number = ML14070299 | ||
Line 19: | Line 19: | ||
=Text= | =Text= | ||
{{#Wiki_filter: | {{#Wiki_filter:[7590-01-P] | ||
NUCLEAR REGULATORY COMMISSION | |||
[Docket Nos. 50-454, 50-455, 50-456, 50-457; NRC-2017-0167] | |||
Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2 AGENCY: Nuclear Regulatory Commission. | |||
ACTION: 10 CFR 2.206 request; receipt. | |||
/RA/}} | ==SUMMARY== | ||
: The U.S. Nuclear Regulatory Commission (NRC) is giving notice that by petition dated February 8, 2017, Barry Quigley (the petitioner) has requested that the NRC take action with regard to Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2. The petitioners requests are included in the SUPPLEMENTARY INFORMATION section of this document. | |||
DATES: [INSERT DATE OF PUBLICATION IN THE FEDERAL REGISTER]. | |||
ADDRESSES: Please refer to Docket ID NRC-2017-0167 when contacting the NRC about the availability of information regarding this document. You may obtain publicly-available information related to this document using any of the following methods: | |||
* Federal Rulemaking Web Site: Go to http://www.regulations.gov and search for Docket ID NRC-2017-0167 Address questions about NRC dockets to Carol Gallagher; telephone: 301-415-3463; e-mail: Carol.Gallagher@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document. | |||
* NRCs Agencywide Documents Access and Management System (ADAMS): | |||
You may obtain publicly-available documents online in the ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ADAMS Public Documents and then select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by e-mail to pdr.resource@nrc.gov. The ADAMS accession number for each document referenced (if it is available in ADAMS) is provided the first time that it is mentioned in this document. | |||
* NRCs PDR: You may examine and purchase copies of public documents at the NRCs PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852. | |||
FOR FURTHER INFORMATION CONTACT: Joel S. Wiebe, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington DC 20555-0001; telephone: | |||
301-415-6606, e-mail: Joel.Wiebe@nrc.gov. | |||
SUPPLEMENTARY INFORMATION: | |||
On February 8, 2017, the petitioner requested that the NRC take action with regard to Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2 (ADAMS Accession No. ML17061A127). The petitioner requested: (1) Issue a violation under part 50 of title 10 of the Code of Federal Regulations (10 CFR), appendix B, Criterion III, Design Control for deficiencies in the analysis of record (AOR) for the main steam isolation valve (MSIV) room pressurization following a high energy line break (HELB), (2) Issue a violation under 10 CFR part 50, appendix B, Criterion XVI, Corrective Action, for failure to update the AOR in a timely manner, (3) Require Exelon (the licensee) to show that the consequences of the secondary missiles | |||
resulting from MSIV room pressurization do not have adverse consequences, (4) Issue a demand for information under 10 CFR 2.204, Demand for information, to compare and contrast the behavior of Exelon management described in the petition with the NRCs policy statement on the attributes of a safety-conscious work environment, and (5) Use Exelons response to number 4, above, on which to determine whether to issue a chilling effects letter. | |||
As the basis for this request, the petitioner states that: (1) Break enthalpies used in the MSIV room pressurization AOR are actually the thermodynamic internal energy of the steam, not the enthalpy. Since in the range of interest, the internal energy is about 13 percent less than the enthalpy, the energy flow to the areas of concern is non-conservative. Steam flow from secondary piping is neglected; (2) Corrective actions to resolve an issue in the AOR are long overdue (8 years) and improperly tracked; (3) A proposed revision to the AOR shows that the MSIV room roof slabs will be ejected by the high pressures in the MSIV rooms becoming potential missiles; and (4) Management dismissed information in the Updated Final Safety Evaluation Report (UFSAR) that supported the concerns about the AOR as excessive detail and directed personnel to remove the information. Management dismissed UFSAR internal inconsistency related to the Break Exclusion Zone without discussion or review and stated that the information supporting the concern could be deleted as an UFSAR cleanup item. Recently, there was an operability concern where engineering management maintained a position of operability in the face of conflicting information. The information that engineering management relied on to support operability was demonstrably irrelevant. | |||
The request, except for the petitioners item 3, which does not request enforcement action, is being treated pursuant to 10 CFR 2.206 of the Commissions regulations. The request has been referred to the Director of the Office of Nuclear Reactor Regulation. As provided by 10 CFR 2.206, appropriate action will be taken on this petition within a reasonable time. The petitioner met with the Petition Review Board (PRB) on | |||
April 13, 2017, to discuss the petition; the transcript of that meeting is an additional supplement to the petition (ADAMS Accession No. ML17111A774). On June 12, 2017, the petition manager informed the petitioner that the PRB accepted the petition items 1, 2, 4, and 5 for review under 10 CFR 2.206. | |||
Dated at Rockville, Maryland, this 20th day of July, 2017. | |||
For the Nuclear Regulatory Commission. | |||
/RA/ | |||
Brian E. Holian, Acting Director Office of Nuclear Reactor Regulation}} |
Latest revision as of 17:29, 4 February 2020
ML17125A247 | |
Person / Time | |
---|---|
Site: | Byron, Braidwood |
Issue date: | 07/20/2017 |
From: | Brian Holian Office of Nuclear Reactor Regulation |
To: | |
Wiebe J | |
Shared Package | |
ML14070299 | List: |
References | |
0EDO-17-00104, CAC TM3111, NRC-2017-0167 | |
Download: ML17125A247 (4) | |
Text
[7590-01-P]
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 50-454, 50-455, 50-456, 50-457; NRC-2017-0167]
Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2 AGENCY: Nuclear Regulatory Commission.
ACTION: 10 CFR 2.206 request; receipt.
SUMMARY
- The U.S. Nuclear Regulatory Commission (NRC) is giving notice that by petition dated February 8, 2017, Barry Quigley (the petitioner) has requested that the NRC take action with regard to Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2. The petitioners requests are included in the SUPPLEMENTARY INFORMATION section of this document.
DATES: [INSERT DATE OF PUBLICATION IN THE FEDERAL REGISTER].
ADDRESSES: Please refer to Docket ID NRC-2017-0167 when contacting the NRC about the availability of information regarding this document. You may obtain publicly-available information related to this document using any of the following methods:
- Federal Rulemaking Web Site: Go to http://www.regulations.gov and search for Docket ID NRC-2017-0167 Address questions about NRC dockets to Carol Gallagher; telephone: 301-415-3463; e-mail: Carol.Gallagher@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document.
- NRCs Agencywide Documents Access and Management System (ADAMS):
You may obtain publicly-available documents online in the ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ADAMS Public Documents and then select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by e-mail to pdr.resource@nrc.gov. The ADAMS accession number for each document referenced (if it is available in ADAMS) is provided the first time that it is mentioned in this document.
- NRCs PDR: You may examine and purchase copies of public documents at the NRCs PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: Joel S. Wiebe, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington DC 20555-0001; telephone:
301-415-6606, e-mail: Joel.Wiebe@nrc.gov.
SUPPLEMENTARY INFORMATION:
On February 8, 2017, the petitioner requested that the NRC take action with regard to Braidwood Station, Units 1 and 2, and Byron Station, Unit Nos. 1 and 2 (ADAMS Accession No. ML17061A127). The petitioner requested: (1) Issue a violation under part 50 of title 10 of the Code of Federal Regulations (10 CFR), appendix B, Criterion III, Design Control for deficiencies in the analysis of record (AOR) for the main steam isolation valve (MSIV) room pressurization following a high energy line break (HELB), (2) Issue a violation under 10 CFR part 50, appendix B, Criterion XVI, Corrective Action, for failure to update the AOR in a timely manner, (3) Require Exelon (the licensee) to show that the consequences of the secondary missiles
resulting from MSIV room pressurization do not have adverse consequences, (4) Issue a demand for information under 10 CFR 2.204, Demand for information, to compare and contrast the behavior of Exelon management described in the petition with the NRCs policy statement on the attributes of a safety-conscious work environment, and (5) Use Exelons response to number 4, above, on which to determine whether to issue a chilling effects letter.
As the basis for this request, the petitioner states that: (1) Break enthalpies used in the MSIV room pressurization AOR are actually the thermodynamic internal energy of the steam, not the enthalpy. Since in the range of interest, the internal energy is about 13 percent less than the enthalpy, the energy flow to the areas of concern is non-conservative. Steam flow from secondary piping is neglected; (2) Corrective actions to resolve an issue in the AOR are long overdue (8 years) and improperly tracked; (3) A proposed revision to the AOR shows that the MSIV room roof slabs will be ejected by the high pressures in the MSIV rooms becoming potential missiles; and (4) Management dismissed information in the Updated Final Safety Evaluation Report (UFSAR) that supported the concerns about the AOR as excessive detail and directed personnel to remove the information. Management dismissed UFSAR internal inconsistency related to the Break Exclusion Zone without discussion or review and stated that the information supporting the concern could be deleted as an UFSAR cleanup item. Recently, there was an operability concern where engineering management maintained a position of operability in the face of conflicting information. The information that engineering management relied on to support operability was demonstrably irrelevant.
The request, except for the petitioners item 3, which does not request enforcement action, is being treated pursuant to 10 CFR 2.206 of the Commissions regulations. The request has been referred to the Director of the Office of Nuclear Reactor Regulation. As provided by 10 CFR 2.206, appropriate action will be taken on this petition within a reasonable time. The petitioner met with the Petition Review Board (PRB) on
April 13, 2017, to discuss the petition; the transcript of that meeting is an additional supplement to the petition (ADAMS Accession No. ML17111A774). On June 12, 2017, the petition manager informed the petitioner that the PRB accepted the petition items 1, 2, 4, and 5 for review under 10 CFR 2.206.
Dated at Rockville, Maryland, this 20th day of July, 2017.
For the Nuclear Regulatory Commission.
/RA/
Brian E. Holian, Acting Director Office of Nuclear Reactor Regulation