05000461/FIN-2008002-02: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 1: | Line 1: | ||
{{finding | {{finding | ||
| title = | | title = the Licensee Discovered That the Wrong Component Was Installed in the B Turbine Driven Reactor Feed Pump Oil Pressure Sensing Logic | ||
| docket = 05000461 | | docket = 05000461 | ||
| inspection report = IR 05000461/2008002 | | inspection report = IR 05000461/2008002 |
Latest revision as of 23:04, 29 May 2018
Site: | Clinton |
---|---|
Report | IR 05000461/2008002 Section 1R19 |
Date counted | Mar 31, 2008 (2008Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.19 |
Inspectors (proximate) | R Jickling J Cassidy D Tharp B Dickson M Mitchell J Neurauter M Ring D Jones V Meghani S Mischke R Russell |
CCA | H.8, Procedure Adherence |
INPO aspect | WP.4 |
' | |