ML24044A108: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 17: | Line 17: | ||
{{#Wiki_filter:February 14, 2024 | {{#Wiki_filter:February 14, 2024 | ||
MEMORANDUM TO: | MEMORANDUM TO: Russell Felts, Director Division of Reactor Oversight (DRO) | ||
Office of Nuclear Reactor Regulation Signed by Kozal, Jason FROM: | Office of Nuclear Reactor Regulation Signed by Kozal, Jason FROM: Jason Kozal, Director on 02/14/24 Division of Operating Reactor Safety (DORS) | ||
Region III Signed by Curtis, David David Curtis, Director | Region III Signed by Curtis, David David Curtis, Director on 02/13/24 Division of Radiological Safety and Security (DRSS) | ||
Region III | Region III | ||
| Line 40: | Line 40: | ||
Marc Ferdas, RI Steven Smith, RII Ami Agrawal, RIV | Marc Ferdas, RI Steven Smith, RII Ami Agrawal, RIV | ||
ADAMS Accession Number: ML24044A108 Publicly Available | ADAMS Accession Number: ML24044A108 Publicly Available Non-Publicly Available Sensitive Non-Sensitive OFFICE RIII RIII RIII RIII NAME DChyu:do AMcCraw DCurtis JKozal DATE 02/13/2024 02/13/2024 02/13/2024 02/14/2024 OFFICIAL RECORD COPY IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Braidwood (BRAI) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 4 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 15 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 19 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 13 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 1 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 12 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s) | ||
Material Handling, Storage, & Transportation 71151 | Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 4 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 3 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 2 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Byron (BYRO) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 22 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 6 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 17 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 23 19 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 6 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 43 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 3 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 4 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 10 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 5 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 4 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Clinton (CLIN) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 12 11 Complete Complete 71111.05 BI Fire Protection A 26 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 3 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 4 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 6 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 40 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 5 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 1 4 Complete Complete - in previous year(s) 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 6 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: D.C. Cook (COOK) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 14 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 2 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 18 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 22 19 Complete Complete 71111.18 BI Plant Modifications A 3 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 12 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 38 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 11 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 7 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 3 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 24 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s) | ||
Material Handling, Storage, & Transportation 71151 | Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 5 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 8 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Davis-Besse (DAVI) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 23 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 15 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 14 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 42 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 9 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.01 | 71124.01 BI Rad Haz Assess Exposure Controls A 0 10 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71124.03 BI Airborne Radioactivity B 3 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 6 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 10 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Dresden (DRES) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 20 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 13 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 20 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 29 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 38 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 11 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 13 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 4 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 12 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Fermi (FERM) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 18 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 10 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 16 15 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 8 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 13 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.01 | 71124.01 BI Rad Haz Assess Exposure Controls A 0 10 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 24 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 3 3 Complete Complete 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s) | ||
Material Handling, Storage, & Transportation 71151 | Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 6 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 14 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: LaSalle (LASA) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 9 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 7 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 4 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Complete Complete - in previous year(s) 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 13 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 15 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 4 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 5 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 13 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 10 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 16 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Monticello (MONT) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 25 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 18 15 Complete Complete 71111.18 BI Plant Modifications A 5 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 15 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 42 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 13 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 17 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 23 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s) | ||
Material Handling, Storage, & Transportation 71151 | Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 6 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 18 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Perry (PERR) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 25 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 17 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 7 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 27 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 50 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Complete Complete - in previous year(s) 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 19 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 21 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 13 9 Complete Complete 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s) | ||
Material Handling, Storage, & Transportation 71151 | Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 10 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 20 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Point Beach (POIN) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 20 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 5 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 12 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 21 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 31 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s) | ||
Staffing/Augmentation 71114.04 | Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 14 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 21 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 3 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 22 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Prairie Island (PRAI) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 14 11 Complete Complete 71111.05 BI Fire Protection A 23 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 2 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 10 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 10 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 19 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 21 19 Complete Complete 71111.18 BI Plant Modifications A 6 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 11 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 46 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 4 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 23 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 0 4 Complete Complete - in previous year(s) 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 1 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 24 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
Region No: | Region No: Quad Cities (QUAD) 3 | ||
Procedure | Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 22 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 9 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 13 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 20 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 31 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 39 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 11 10 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 25 of 26 IR Report 8a Baseline Inspection Completion By Site | ||
71124.03 | 71124.03 BI Airborne Radioactivity B 5 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 4 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 10 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 7 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 4 0 Complete Complete | ||
2/12/2024 12:42:10 PM | 2/12/2024 12:42:10 PM Page 26 of 26}} | ||
Revision as of 15:17, 5 October 2024
| ML24044A108 | |
| Person / Time | |
|---|---|
| Issue date: | 02/14/2024 |
| From: | David Curtis, Jason Kozal NRC/RGN-III/DORS |
| To: | Russell Felts NRC/NRR/DRO |
| References | |
| Download: ML24044A108 (1) | |
Text
February 14, 2024
MEMORANDUM TO: Russell Felts, Director Division of Reactor Oversight (DRO)
Office of Nuclear Reactor Regulation Signed by Kozal, Jason FROM: Jason Kozal, Director on 02/14/24 Division of Operating Reactor Safety (DORS)
Region III Signed by Curtis, David David Curtis, Director on 02/13/24 Division of Radiological Safety and Security (DRSS)
Region III
SUBJECT:
CALENDAR YEAR 2023 REACTOR OVERSIGHT PROCESS BASELINE INSPECTION PROGRAM COMPLETION REGION III
The purpose of this memorandum is to confirm that the required baseline inspections for which Region III is responsible have been completed 100 percent for the calendar year 2023 inspection cycle in accordance with Inspection Manual Chapter 2515, Light-Water Reactor Inspection Program - Operations Phase. Enclosed is a table that provides the completion status of baseline procedures for all Region III sites (IR Report 8a). Please note that this table does not include the status for procedures associated with the security and safeguards inspection program; however, we have completed the baseline inspections associated with security and safeguards for which we are responsible.
If you have any questions or desire additional details, please contact the individual listed below.
CONTACT: Aaron T. McCraw, DORS, RIII (630) 829-96 Memorandum to Russell Felts from Jason Kozal dated February 14, 2024.
SUBJECT:
CALENDAR YEAR 2023 REACTOR OVERSIGHT PROCESS BASELINE INSPECTION PROGRAM COMPLETION REGION III
DISTRIBUTION:
John Giessner, RIII Mohammed Shuaibi, RIII Nestor J Feliz Adorno, RIII Jared Heck, RIII Pat Finney, NRR (IRAB)
Tom Hipschman, NRR (IRIB)
Ronald Cureton, NRR (IRAB)
Marc Ferdas, RI Steven Smith, RII Ami Agrawal, RIV
ADAMS Accession Number: ML24044A108 Publicly Available Non-Publicly Available Sensitive Non-Sensitive OFFICE RIII RIII RIII RIII NAME DChyu:do AMcCraw DCurtis JKozal DATE 02/13/2024 02/13/2024 02/13/2024 02/14/2024 OFFICIAL RECORD COPY IR Report 8a Baseline Inspection Completion By Site
Region No: Braidwood (BRAI) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 4 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 15 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 19 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 13 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 1 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 12 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s)
Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 4 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 3 0 Complete Complete
2/12/2024 12:42:10 PM Page 2 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Byron (BYRO) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 22 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 6 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 17 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 23 19 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 6 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 43 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 3 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 4 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 10 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 5 0 Complete Complete
2/12/2024 12:42:10 PM Page 4 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Clinton (CLIN) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 12 11 Complete Complete 71111.05 BI Fire Protection A 26 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 3 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 4 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 6 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 40 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 5 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 1 4 Complete Complete - in previous year(s) 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete
2/12/2024 12:42:10 PM Page 6 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: D.C. Cook (COOK) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 14 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 2 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 18 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 22 19 Complete Complete 71111.18 BI Plant Modifications A 3 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 12 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 38 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 11 10 Complete Complete
2/12/2024 12:42:10 PM Page 7 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 3 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 24 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s)
Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 5 0 Complete Complete
2/12/2024 12:42:10 PM Page 8 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Davis-Besse (DAVI) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 23 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 15 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 4 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 14 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 42 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete
2/12/2024 12:42:10 PM Page 9 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.01 BI Rad Haz Assess Exposure Controls A 0 10 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71124.03 BI Airborne Radioactivity B 3 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 6 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete
2/12/2024 12:42:10 PM Page 10 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Dresden (DRES) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 20 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 13 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 20 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 29 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 38 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 11 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 13 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 4 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete
2/12/2024 12:42:10 PM Page 12 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Fermi (FERM) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 18 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 10 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 16 15 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 8 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s)
2/12/2024 12:42:10 PM Page 13 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.01 BI Rad Haz Assess Exposure Controls A 0 10 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 6 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 24 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 3 3 Complete Complete 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s)
Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 6 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 2 0 Complete Complete
2/12/2024 12:42:10 PM Page 14 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: LaSalle (LASA) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 21 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 9 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 1 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 7 5 Complete Complete 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 4 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Complete Complete - in previous year(s) 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 13 10 Complete Complete
2/12/2024 12:42:10 PM Page 15 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 4 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 5 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 13 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 10 0 Complete Complete
2/12/2024 12:42:10 PM Page 16 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Monticello (MONT) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 25 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 14 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 18 15 Complete Complete 71111.18 BI Plant Modifications A 5 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 15 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 42 34 Complete Complete 71114.01 EP Exercise Evaluation B 1 1 Complete Complete 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 13 10 Complete Complete
2/12/2024 12:42:10 PM Page 17 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 1 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 23 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s)
Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 6 0 Complete Complete
2/12/2024 12:42:10 PM Page 18 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Perry (PERR) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 25 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 17 10 Complete Complete 71111.15 BI Oper Determinations/Functionality A 19 15 Complete Complete 71111.18 BI Plant Modifications A 7 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 3 0 Complete Complete 71111.21M BI CETI Y4 27 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 50 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Complete Complete - in previous year(s) 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 19 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 21 17 Complete Complete 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 13 9 Complete Complete 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 0 8 Complete Complete - in previous year(s)
Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 13 13 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 10 0 Complete Complete
2/12/2024 12:42:10 PM Page 20 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Point Beach (POIN) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 3 2 Complete Complete 71111.04 BI Equipment Alignment A 11 11 Complete Complete 71111.05 BI Fire Protection A 20 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 5 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 0 1 Complete Complete - in previous year(s) 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 8 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 8 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 12 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 21 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 31 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 37 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306 71114.02 EP Alert and Notification System Testing B 0 1 Complete Complete - in previous year(s) 71114.03 EP Emergency Response Organizational B 0 1 Complete Complete - in previous year(s)
Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 0 1 Complete Complete - in previous year(s) 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 1 1 Complete Complete 71114.08 EP Exercise Evaluation - Scenario Review B 1 1 Complete Complete 71124.01 BI Rad Haz Assess Exposure Controls A 14 10 Complete Complete
2/12/2024 12:42:10 PM Page 21 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 2 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 3 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 0 0 Complete Complete - opportunity to apply full procedure not available iaw IMC 0306
2/12/2024 12:42:10 PM Page 22 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Prairie Island (PRAI) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 4 2 Complete Complete 71111.04 BI Equipment Alignment A 14 11 Complete Complete 71111.05 BI Fire Protection A 23 18 Complete Complete 71111.06 BI Flood Protection Measures A 2 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08P BI Inservice Inspection Activities (PWR) R 2 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 10 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 10 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 19 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 21 19 Complete Complete 71111.18 BI Plant Modifications A 6 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 0 19 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.03 BI Commercial Grade Dedication Y4 11 9 Complete Complete 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 46 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 4 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 12 10 Complete Complete
2/12/2024 12:42:10 PM Page 23 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 0 4 Complete Complete - in previous year(s) 71124.04 BI Occupational Dose Assessment B 0 4 Complete Complete - in previous year(s) 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 11 8 Complete Complete Material Handling, Storage, & Transportation 71151 BI Performance Indicator Verification A 28 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 5 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 1 1 Complete Complete 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 1 0 Complete Complete
2/12/2024 12:42:10 PM Page 24 of 26 IR Report 8a Baseline Inspection Completion By Site
Region No: Quad Cities (QUAD) 3
Procedure IPE Cycle Title Frequency Sample Minimum Status Note Completed Sample 71111.01 BI Adverse Weather Protection A 2 2 Complete Complete 71111.04 BI Equipment Alignment A 13 11 Complete Complete 71111.05 BI Fire Protection A 22 18 Complete Complete 71111.06 BI Flood Protection Measures A 1 1 Complete Complete 71111.07A BI Heat Sink Performance A 1 1 Complete Complete 71111.08G BI Inservice Inspection Activities (BWR) R 1 0 Complete Complete 71111.11A BI Licensed Op Requal & Perform (Annual) A 1 1 Complete Complete 71111.11B BI Licensed Op Requal & Perform (Biennial) B 1 1 Complete Complete 71111.11Q BI Licensed Op Requal & Perform (Quarterly) A 9 8 Complete Complete 71111.12 BI Maintenance Effectiveness A 9 8 Complete Complete 71111.13 BI Maint Risk Assessmnts & Emer Wk Ctrl A 13 12 Complete Complete 71111.15 BI Oper Determinations/Functionality A 20 19 Complete Complete 71111.18 BI Plant Modifications A 2 2 Complete Complete 71111.20 BI Refueling and Other Outage Activities R 2 0 Complete Complete 71111.21M BI CETI Y4 31 19 Complete Complete 71111.21N.03 BI Commercial Grade Dedication Y4 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.04 BI Age-Related Degrad Y4 0 12 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.21N.05 BI FPTI Y4 0 5 Not Applicable Not Applicable - completion not required during this inspection cycle 71111.24 BI Test & Maint of Equip Important to Risk A 39 34 Complete Complete 71114.01 EP Exercise Evaluation B 0 1 Complete Complete - in previous year(s) 71114.02 EP Alert and Notification System Testing B 1 1 Complete Complete 71114.03 EP Emergency Response Organizational B 1 1 Complete Complete Staffing/Augmentation 71114.04 EP Emrgcy Act Lvl & Emrgcy Pln Chngs A 1 1 Complete Complete 71114.05 EP Maintenance of EP B 1 1 Complete Complete 71114.06 EP Drill Evaluation A 3 3 Complete Complete 71114.07 EP Exercise Evaluation - Hostile Action (HA) B 0 1 Not Applicable Not Applicable - completion not required during this inspection cycle 71114.08 EP Exercise Evaluation - Scenario Review B 0 1 Complete Complete - in previous year(s) 71124.01 BI Rad Haz Assess Exposure Controls A 11 10 Complete Complete
2/12/2024 12:42:10 PM Page 25 of 26 IR Report 8a Baseline Inspection Completion By Site
71124.03 BI Airborne Radioactivity B 5 4 Complete Complete 71124.04 BI Occupational Dose Assessment B 4 4 Complete Complete 71124.05 BI Radiation Monitoring Instrumentation B 0 17 Complete Complete - in previous year(s) 71124.06 BI Radioactive Gaseous and Liquid Effluent Treatment T 0 9 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.07 BI Radiological Environmental Monitoring Program T 0 3 Not Applicable Not Applicable - completion not required during this inspection cycle 71124.08 BI Radioactive Solid Waste Processing & Radioactive B 10 8 Complete Complete - opportunity to apply full procedure Material Handling, Storage, & Transportation not available iaw IMC 0306 71151 BI Performance Indicator Verification A 24 24 Complete Complete 71151 EP Performance Indicator Verification A 3 3 Complete Complete 71152A BI PI & R Annual A 7 4 Complete Complete 71152B BI Problem Identification and Resolution (Biennial) B 0 1 Complete Complete - in previous year(s) 71152S BI PI & R Semi Annual S 2 2 Complete Complete 71153 BI Follow Up of Events and NOED R 4 0 Complete Complete
2/12/2024 12:42:10 PM Page 26 of 26