{{#Wiki_filter:October 5, 2021 Dr. Prasant Mohapatra Vice Chancellor for Research Department of Computer Science University of California Davis, CA 95616
 
==SUBJECT:==
REGENTS OF THE UNIVERSITY OF CALIFORNIA - APPROVAL OF THE REVISED NUCLEAR RADIATION CENTER SELECTION AND TRAINING PLAN (EPID L-2020-NFR-0002)
 
==Dear Dr. Mohapatra:==
 
The U.S. Nuclear Regulation Commission (NRC) staff completed its review of the University of California, Davis (UCD) McClellan Nuclear Research Center (MNRC) Selection and Training Plan for Reactor Personnel (MNRC-0009-DOC-05), dated September 2021 (Agencywide Documents Access and Management System Accession No. ML21269A001), and finds the revised selection and training plan for reactor personnel to be in accordance with the applicable regulations contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 55, Operators Licenses, and consistent with the guidance contained in industry standard American National Standards Institute/American Nuclear Society-15.4-2016, Selection and Training of Personnel for Research Reactors.
During its review, the NRC staff noticed that the revised UCD/MNRC Selection and Training Plan for Reactor Personnel does not include the requirements associated with 10 CFR 55.59 (c)(6) Alternative training programs. If the licensee finds the need to implement an alternative training program in the future, the licensee will have to submit one to the NRC for approval.
We request you implement your approved selection and training plan immediately.
 
P. Mohapatra                                If you have any questions, please contact me at (301) 415-5656, or by electronic mail at Paulette.Torres@nrc.gov.
Sincerely, Signed by Torres, Paulette on 10/05/21 Paulette Torres, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130 cc: See next page
 
University of California-Davis/McClellan  Docket No. 50-607 cc:
David Reap, Radiation Safety Officer 5335 Price Avenue, Bldg. 258 McClellan, CA 95652-2504 California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814 Radiologic Health Branch California Department of Public Health P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115 Dr. Wesley D. Frey, Reactor Director McClellan Nuclear Research Center University of California, Davis 5335 Price Avenue, Building 258 McClellan, CA 95652-2504
 
ML21252A757                                            NRR-106 OFFICE NRR/DANU/UNPL/PM NRR/DANU/UNPL/LA        NRR/DANU/UNPL/BC NRR/DANU/UNPL/PM NAME    PTorres            NParker              JBorromeo        PTorres DATE    9/10/2021          9/27/2021          10/4/2021        10/5/2021}}

Latest revision as of 15:44, 18 January 2022

University of California-Davis/MCCLELLAN - Approval of the Revised Nuclear Radiation Center Selection and Training Plan
ML21252A757
Person / Time
Site: University of California-Davis
Issue date: 10/05/2021
From: Paulette Torres
NRC/NRR/DANU/UNPL
To: Mohapatra P
McClellan Nuclear Research Center
Torres P
References
EPID L-2020-NFR-0002
Download: ML21252A757 (4)


Text

October 5, 2021 Dr. Prasant Mohapatra Vice Chancellor for Research Department of Computer Science University of California Davis, CA 95616

SUBJECT:

REGENTS OF THE UNIVERSITY OF CALIFORNIA - APPROVAL OF THE REVISED NUCLEAR RADIATION CENTER SELECTION AND TRAINING PLAN (EPID L-2020-NFR-0002)

Dear Dr. Mohapatra:

The U.S. Nuclear Regulation Commission (NRC) staff completed its review of the University of California, Davis (UCD) McClellan Nuclear Research Center (MNRC) Selection and Training Plan for Reactor Personnel (MNRC-0009-DOC-05), dated September 2021 (Agencywide Documents Access and Management System Accession No. ML21269A001), and finds the revised selection and training plan for reactor personnel to be in accordance with the applicable regulations contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 55, Operators Licenses, and consistent with the guidance contained in industry standard American National Standards Institute/American Nuclear Society-15.4-2016, Selection and Training of Personnel for Research Reactors.

During its review, the NRC staff noticed that the revised UCD/MNRC Selection and Training Plan for Reactor Personnel does not include the requirements associated with 10 CFR 55.59 (c)(6) Alternative training programs. If the licensee finds the need to implement an alternative training program in the future, the licensee will have to submit one to the NRC for approval.

We request you implement your approved selection and training plan immediately.

P. Mohapatra If you have any questions, please contact me at (301) 415-5656, or by electronic mail at Paulette.Torres@nrc.gov.

Sincerely, Signed by Torres, Paulette on 10/05/21 Paulette Torres, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130 cc: See next page

University of California-Davis/McClellan Docket No. 50-607 cc:

David Reap, Radiation Safety Officer 5335 Price Avenue, Bldg. 258 McClellan, CA 95652-2504 California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814 Radiologic Health Branch California Department of Public Health P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115 Dr. Wesley D. Frey, Reactor Director McClellan Nuclear Research Center University of California, Davis 5335 Price Avenue, Building 258 McClellan, CA 95652-2504