ML070680087: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML070680087
| number = ML070680087
| issue date = 11/29/1999
| issue date = 11/29/1999
| title = Vym 99/148, ASME Section Xi Subsection IWE Report on Evaluation of 1998 Torus Inspections, 11/29/1999, Appendix B, Appendix C, Appendix D (Part 2)
| title = Vym 99/148, ASME Section XI Subsection IWE Report on Evaluation of 1998 Torus Inspections, 11/29/1999, Appendix B, Appendix C, Appendix D (Part 2)
| author name =  
| author name =  
| author affiliation = - No Known Affiliation
| author affiliation = - No Known Affiliation
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:1 VERMONT YANKEE 1998 IWE TORUS INSPECTION REPORT , ,161~~ APPENDIX B BOTTOM TEST STRIPS BAYS 8 AND 16 PLOTS OF UT THICKNESS READINGS AND EVALUATION OF PLATE THICKNESS VAR I AT1 0 N I ! ':j .. . PLAN VIEW
{{#Wiki_filter:1 VERMONT YANKEE 1998 IWE TORUS INSPECTION REPORT
                                      , 1 6 1 ~ ~
APPENDIX B BOTTOM TEST STRIPS BAYS 8 AND 16 PLOTS OF UT THICKNESS READINGS AND EVALUATION OF PLATE THICKNESS VAR IAT10N
 
I
  . :j' . PLAN V I E W BOTTOM SECTION
 
i                                                    998 1 i :            LZ6 1 I    t I    t 882 1 I
6PZ 1 I
OlZl 1LC 1 ZECC E60 1 t
PSO 1 I      1 11 I    1 I                s101 I            I  '
I      1 I        #                    9L6 LE6 w                                                  868 6S8 028 I,
t, 18L I
ZPL f                                              I t
EOL
!    I II 1                                          999 I
I                                        sz9 I
98s LPS 80s 69P OEP 16E IS E 16 PLZ SEZ I
96 C 1
I,'      I, LS 1
                                                -+
811 6L OP 1
co x
 
9981 LZGC 8821
  -    6PZ1 3    OLZl CLll Q
      \ ZECl
    'J  E60 1 PSOC 0      SCOl 9L6 LE6 868 v) 6S8 v)
W       

Latest revision as of 19:13, 13 March 2020

Vym 99/148, ASME Section XI Subsection IWE Report on Evaluation of 1998 Torus Inspections, 11/29/1999, Appendix B, Appendix C, Appendix D (Part 2)
ML070680087
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 11/29/1999
From:
- No Known Affiliation
To:
Office of Nuclear Reactor Regulation
References
Download: ML070680087 (31)


Text

1 VERMONT YANKEE 1998 IWE TORUS INSPECTION REPORT

, 1 6 1 ~ ~

APPENDIX B BOTTOM TEST STRIPS BAYS 8 AND 16 PLOTS OF UT THICKNESS READINGS AND EVALUATION OF PLATE THICKNESS VAR IAT10N

I

. :j' . PLAN V I E W BOTTOM SECTION

i 998 1 i : LZ6 1 I t I t 882 1 I

6PZ 1 I

OlZl 1LC 1 ZECC E60 1 t

PSO 1 I 1 11 I 1 I s101 I I '

I 1 I # 9L6 LE6 w 868 6S8 028 I,

t, 18L I

ZPL f I t

EOL

! I II 1 999 I

I sz9 I

98s LPS 80s 69P OEP 16E IS E 16 PLZ SEZ I

96 C 1

I,' I, LS 1

-+

811 6L OP 1

co x

9981 LZGC 8821

- 6PZ1 3 OLZl CLll Q

\ ZECl

'J E60 1 PSOC 0 SCOl 9L6 LE6 868 v) 6S8 v)

W OZ8 18L ZPL EOL P99 sz9 989 LPS 80s 699 OEP 16E ZSB El I PLZ SEZ 961.

LS 1 811 6L OP L

03 Ln.

0 x

I BAY 8 OUT-1 OUT-2 OUT-3 IN-1 IN-2 BOTTOM STRIP MAXIMUM 0.61 1 0.640 0.599 0.612 0.615 MINIMUM 0.573 0.574 0.556 0.577 0.546 AVERAGE 0.601 0.615 0.582 0.602 0.602 STANDARD DEV. 0.00785 0.00998 0.00792 0.00662 0.00803 STD DEV  % 1.31 1.62 1.36 1.10 1.34 AVERAGE AVE-1(STDDEV) 0.593 0.605 0.574 0.595 0.594 AVE-2(STDDEV) 0.585 0.595 0.566 0.589 0.586 INSTRUMENT ACCURACY +/- .004"

I I 1 I 11 I 1 21 31 41 51 I

61 71 81 I 91 I

101 I

111 121 131 141 151 161 171 181 n I

191 I 201 I I I

211 1 ' 1 221 I

23 1 241 I

t 25' 26' I

27' I I I 28' I

29 I 1' 30 31 I I I 32 I 33

96L s LL P69 6L9 ZS9 169 0 19 68s 89s LPS 92s sos P8P E9P ZPP c ZP OOP 6LE 8SE LEE 91s S6Z PLZ ESZ Z6Z 1cz 06 I.

691 8P 1 LZ 1 901 S8 P9 EP zz c

1 I 1 11 I

' I 21 1 I 1 31 I

41 I 51 61 I I

71 I 81 I I 91 101 I

111 121 I 131 141 I

151 I 'I 161 I

171 181 191 201 211 I

221 231 I I 24 1 251 26 1 1 1 27 1 I I 281 I 291 301 31 1 I I '

1

eaw3 11 189 I I 199 1P9 129 109 I

18s 19s 1PS 1zs 10s I 18P I

19t 3

\

1PP CZP COP 18E 19E 1PE

! CZE 1OE 18Z 19z CPZ I

czz coz I

181 191 LPC 121 LO 1 C8 C9 I

EP I cz 1

ln 2

I 0 P P 0 01 VI 0 VI VI h) P OJ b 1

I 20 39 58 77 96 115 134 153 172 191 210 229 248 267 286 Q,

305 W 324 343 rn 5-362 z k

381 400 419 438 457 476 495 P

M 514 533 z

552 571 590 I

609 628 647 666 685

8P'O ZS'O jr

-4 L

PS'O f 3k 9S'O

' 8S'O

- 9'0

- 29'0

- P9'0 199.0

0 0 0 0 0 0

0 ul VI '0, b, '0, ul N P 0, z ul N P 0, Q, E 03 I

1 t 1 I 39 I

77 115 153 191 229 I

267 305 z

_L 343 301 419 457 I

495 533 571 609 1 I

647 I 685 ,;?

723 761

a I N C

799 e 837 4 875 913 951 989 1027 -

1062 I I 110: I 1141 I 117E 11 1217 125:

129:

133' 136!

3 BAY 16 OUT-1 OUT-2 OUT-3 IN-1 in-2 BOTTOM STRIP MAXIMUM 0.634 0.648 0.629 0.644 0.629 MINIMUM 0.589 0.566 0.566 0.578 0.573 AVERAGE 0.609 0.61 2 0.585 0.608 0.603 STANDARD DEV. 0.00622 0.00957 0.00623 0.00763 0.00657 STDDEV % I.02 I.56 I.06 1.25 1.09 AVERAGE AVE-1 (STDDEV) 0.603 0.602 0.579 0.600 0.597 0.597 0.592 0.573 0.593 0.590 INSTRUMENT ACCURACY +/- .004"

INCH 0 P 0 P 0 a VI VI a P oa b N cn 1

a 20 39 a 58 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 38 1 400 419 438 457 476 495 514 533 552 571 590 609 628 647 666 i 685

1 II I

20 39 58 I 77 96 115 I 134 I I

I 153 I

172 191 210 I 229 248 I I

267 I I

286 305 I 1 1 324 1 1 343 I 362 11 38 I I

400 I I I) 419 I

438 457 476 I 495 514 533 552 571 590 609 I

628 647 I 666 I

1 1 685 I 3m

0 0 0 P 'a, 01 VI 0 m x 8w P (D

z b .-L 10 m 4 a l

I 1 I 10 I I 19 1

I 28 37 46 55 64 73 82 91 I

100 109 I 118 127 136 145 154 163 172 181 190 199 208 217 226 235 I

244 253 262 I I 271 280 289

)

298 I

' .I

ZS'O w PS'O 9S'O 3-?

0 I

i5 c 8S'O 6

9'0 Z9'0 99'0

682 082 CLZ L9Z is2 PPZ SEZ I

9zz I 1. CZ

  1. 02

$6C 16 i C8 C I

tl1 E9 C I

PS 1 SP 1 9E i LZ C I

8k L

'I 60 1 1 00 i C6 I

28 EL p9 s5 I '

9P LE 82 6b I

01 L C

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations

-Y Location UT Measured Acceptance Margin d

Margin Ave. Thickness

-2.

QA Identifier Thickness Criteria (inch) (percent) Circumferential (inch)

Note 1 (inch)

Note 2 Note 3 Note 4 Stress (inch)

Note 5 z

BAY1-A01 0.601 0.570 0.031 5.44 BAY1-A02 0.615 0.570 0.045 7.89 BAY1-A03 0.61 4 0.570 0.044 7.72 BAY1-A04 0.593 0.570 0.023 4.04 0.606 BAY1-A05 0.595 0.574 0.021 3.66 BAY1-A06 0.604 0.574 0.030 5.23 BAY 1-A07 0.607 0.574 0.033 5.75 BAY 1-A08 0.602 0.574 0.028 4.88 0.602 BAY1-A09 0.591 0.574 0.017 2.96 BAY1-A10 0.594 0.574 0.020 3.48 BAY 1-AI 1 0.595 0.574 0.021 3.66 BAY 1-AI 2 0.597 0.574 0.023 4.01 0.594 BAY1-A13 0.597 0.570 0.027 4.74 BAY1-A14 0.598 0.570 0.028 4.91 BAY1-AI 5 0.590 0.570 0.020 3.51 BAY 1-AI 6 0.594 0.570 0.024 4.21 0.595 BAY2-A01 0.577 0.570 0.007 1.23 BAY2-A02 0.622 0.570 0.052 9.12 BAY2-AO3 0.623 0.570 0.053 9.30 BAY2-AO4 0.595 0.570 0.025 4.39 0.604 BAY2-A05 0.583 0.574 0.009 1.57 BAY2-A06 0.625 0.574 0.051 8.89 BAY2-AO7 0.627 0.574 0.053 9.23 BAY2-AO8 0.594 0.574 0.020 3.48 0.607 BAY2-AO9 0.610 0.574 0.036 6.27 BAY2-A10 0.611 0.574 0.037 6.45 BAY2-AlI 0.596 0.574 0.022 3.83 BAY2-A12 0.599 0.574 0.025 4.36 0.604 BAY2-AI3 0.614 0.570 0.044 7.72 BAY2-AI4 0.613 0.570 0.043 7.54 BAY2-Al5 0.594 0.570 0.024 4.21 BAY2-Al6 0.597 0.570 0.027 4.74 0.605 BAY2-AI7 0.575 0.566 0.009 1.59 BAY2 A I 8 0.577 0.559 0.018 3.22 Page 1 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY3-A01 0.594 0.570 0.024 4.21 BAY3-A02 0.61 6 0.570 0.046 8.07 BAY3-A03 0.613 0.570 0.043 7.54 BAY3-A04 0.604 0.570 0.034 5.96 0.607 BAY3-A05 0.600 0.574 0.026 4.53 BAY3-AO6 0.625 0.574 0.051 8.89 BAY3-A07 0.621 0.574 0.047 8.19 BAY3-A08 0.608 0.574 0.034 5.92 0.614 BAY3-AO9 0.612 0.574 0.038 6.62 BAY3-A10 0.61 8 0.574 0.044 7.67 BAY3-All 0.600 0.574 0.026 4.53 BAY3-Al2 0.604 0.574 0.030 5.23 0.609 BAY3-Al3 0.608 0.570 0.038 6.67 BAY3-A14 0.614 0.570 0.044 7.72 BAY3-AI 5 0.600 0.570 0.030 5.26 BAY3-AI6 0.599 0.570 0.029 5.09 0.605 BAY4-A01 0.601 0.570 0.031 5.44 BAY4-A02 0.631 0.570 0.061 10.70 BAY4-AO3 0.634 0.570 0.064 11.23 BAY4-AO4 0.603 0.570 0.033 5.79 0.617 BAY4-AO5 0.607 0.574 0.033 5.75 BAY4-A06 0.630 0.574 0.056 9.76 BAY4-AO7 0.636 0.574 0.062 10.80 BAY4-AO8 0.601 0,574 0.027 4.70 0.619 BAY4-AO9 0.606 0.574 0.032 5.57 BAY4-A10 0.609 0.574 0.035 6.10 BAY4-All 0.574 0.574 0,000 0.00 BAY4-Al2 0.573' 0.574 -0.001 -0.17 0.591 BAY4-Al3 0.610 0.570 0.040 7.02 BAY4-AI4 0.613 0.570 0.043 7.54 BAY4-A15 0.576 0.570 0.006 1.05 BAY4-Al6 0.576 0.570 0.006 1.05 0.594 BAY4-Al7 0.576 0.566 0.010 1.77 BAY4-Al8 0.581 0.559 0.022 3.94 Page 2 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY5-A01 0.594 0.570 0.024 4.21 BAY5-A02 0.629 0.570 0.059 10.35 BAY5-AO3 0.634 0.570 0.064 11.23 BAY5-A04 0.592 0.570 0.022 3.86 0.61 2 BAY5-A05 0.592 0.574 0.01 8 3.14 BAY5-A06 0.631 0.574 0.057 9.93 BAY5-A07 0.632 0.574 0.058 10.10 BAY5-AO8 0.588 0.574 0.014 2.44 0.611 BAY5-AO9 0.596 0.574 0.022 3.83 BAY5-A10 0.597 0.574 0.023 4.01 BAYS-A11 0.599 0.574 0.025 4.36 BAY5-Al2 0.597 0.574 0.023 4.01 0.597 BAY5-A13 0.595 0.570 0.025 4.39 BAY5-Al4 0.597 0.570 0.027 4.74 BAY5-Al5 0.596 0.570 0.026 4.56 BAY5-A16 0.596 0.570 0.026 4.56 0.596 BAY6-A01 0.588 0.570 0.01 8 3.16 BAY6-AO2 0.612 0.570 0,042 7.37 BAY6-A03 0.61 1 0.570 0.041 7.1 9 BAY6-A04 0.594 0.570 0.024 4.21 0.601 BAY6-AO5 0.584 0.574 0.01 0 1.74 BAY6-AO6 0.61 7 0.574 0,043 7.49 BAY6-A07 0.617 0.574 0.043 7.49 BAY6-AO8 0.594 0.574 0.020 3.48 0.603 BAY6-A09 0.607 0.574 0.033 5.75 BAY6-A10 0.604 0.574 0.030 5.23 BAY6-A11 0.61 1 0.574 0.037 6.45 BAY6-A12 0.608 0.574 0.034 5.92 0.608 BAY6-Al3 0.601 0.570 0.031 5.44 BAY6-Al4 0.600 0.570 0.030 5.26 BAY6-A15 0.617 0.570 0.047 8.25 BAY6-A 16 0.613 0.570 0.043 7.54 0.608 Page 3 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note2 . Note 5 BAY7-A01 0,578 0.570 0.008 1.40 BAY7-A02 0.622 0.570 0.052 9.12 BAY7-A03 0.627 0.570 0.057 10.00 BAY7-AO4 0.596 0.570 0.026 4.56 0.606 BAY7-A05 0.577 0.574 0.003 0.52 BAY7-AO6 0.61 9 0.574 0.045 7.84 BAY7-AO7 0.624 0.574 0.050 8.71 BAY7-AO8 0.599 0.574 0.025 4.36 0.605 BAY7-AO9 0.600 0.574 0.026 4.53 BAY7-AI 0 0.600 0.574 0.026 4.53 BAY7-A11 0.592 0.574 0.018 3.14 BAY7-Al2 0.591 0.574 0.017 2.96 0.596 BAY7-A13 0.598 0.570 0.028 4.91 BAY7-Al4 0.592 0.570 0.022 3.86 BAY7-AI 5 0.596 0.570 0.026 4.56 BAY7-Al6 0.597 0.570 0.027 4.74 0.596 BAY7-A17 0.581 0.566 0.015 2.65 BAY7-Al8 0.581 0.559 0.022 3.94 BAYB-A01 0.583 0.570 0.013 2.28 BAY8-A02 0.61 5 0.570 0.045 7.89 BAY8-AO3 0.614 0.570 0.044 7.72 BAY8-A04 0.606 0.570 0.036 6.32 0.605 BAY8-A05 0.586 0.574 0.012 2.09 BAY8-A06 0.609 0.574 0.035 6.10 BAY8-A07 0.613 0.574 0.039 6.79 BAY8-A08 0.607 0.574 0.033 5.75 0.604 BAY8-AO9 0.608 0.574 0.034 5.92 BAY8-A10 0.607 0.574 0.033 5.75 BAY8-Al1 0.605 0.574 0.031 5.40 BAY8-Al2 0.598 0.574 0.024 4.18 0.605 BAY8-A13 0.608 0.570 0.038 6.67 BAY8-Al4 0.607 0.570 0.037 6.49 BAY8-Al5 0.601 0.570 0.031 5.44 BAY8-A16 0.603 0.570 0.033 5.79 0.605 Page 4 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY9-A01 0.594 0.570 0.024 4.21 BAY9-AO2 0.610 0.570 0.040 7.02 BAY9-A03 0.609 0.570 0.039 6.84 BAY9-AO4 0.599 0.570 0.029 5.09 0.603 BAY9-AO5 0.590 0.574 0.01 6 2.79 BAY9-A06 0.606 0.574 0.032 5.57 BAY9-A07 0.601 0.574 0.027 4.70 BAY9-AO8 0.596 0.574 0.022 3.83 0.598 BAY9-A09 0.599 0.574 0.025 4.36 BAY9-A10 0.600 0.574 0.026 4.53 BAYS-A11 0.582 0.574 0.008 1.39 BAY9-AI2 0.593 0.574 0.019 3.31 , 0,594 BAY9-Al3 0.601 0.570 0.031 5.44 BAYS-A14 0.601 0.570 0.031 5.44 e* 0.570 0.023 4.04 BAYS-A15 0.593

! BAYS-A16 0.591 0.570 0.021 3.68 0.597 BAY10-A01 0.585 0.570 0.01 5 2.63 BAY1O-A02 0.629 0.570 0.059 10.35 BAY 10-A03 0.631 0.570 0.061 10.70 BAY10-A04 0.584 0.570 0.01 4 2.46 0.607 BAY 10-A05 0.586 0.574 0.012 2.09 BAY10-A06 0.628 0.574 0.054 9.41 BAY10-A07 0.629 0.574 0.055 9.58 BAY10-A08 0.583 0.574 0.009 1.57 0.607 BAY10-A09 0.598 0.574 0.024 4.1 8 BAY10-A10 0.597 0.574 0.023 4.01 BAY1O-A11 0.598 0.574 0,024 4.1 8 BAY1O-A12 0.596 0.574 0.022 3.83 0.597 BAY1O-AI 3 0.593 0.570 0.023 4.04 BAY1O-A14 0.592 0.570 0.022 3.86 BAY1O-A15 0.594 0.570 0.024 4.21 BAY1O-A16 0.595 0.570 0.025 4.39 0.594 BAY1O-A17 0.588 0.566 0.022 3.89 BAY1O-A18 0.589 0.559 0.030 5.37 Page 5 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY 11-A01 0.586 0.570 0.016 2.81 BAY 11-A02 0.618 0.570 0.048 8.42 BAY11-A03 0.617 0.570 0.047 8.25 BAY11-A04 0.594 0.570 0.024 4.21 0.604 BAY1I-A05 0.588 0.574 0.014 2.44 BAY11-A06 0.621 0.574 0.047 8.19 BAY11-A07 0.61 8 0.574 0.044 7.67 BAY11-A08 0.592 0.574 0.01 8 3.14 0.605 BAY11-A09 0.585 0.574 0.01 1 1.92 BAY11-A10 0.586 0.574 0.012 2.09 BAY11-A1 1 0.602 0.574 0.028 4.88 BAY11-A12 0.601 0.574 0.027 4.70 0.594 BAY11-A13 0.587 0.570 0.017 2.98 BAY11-A14 0.589 0.570 0.019 3.33 BAY11-A15 0.598 0.570 0.028 4.91 BAY11-A16 0.598 0.570 0.028 4.91 0.593 BAY12-A01 0.609 0.570 0.039 6.84 BAY12-A02 0.642 0.570 . 0.072 12.63 BAY12-A03 0.640 0.570 0.070 12.28 BAY12-A04 0.593 0.570 0.023 4.04 0.621 BAY12-A05 0.61 0 0.574 0,036 6.27 BAY12-A06 0.636 0.574 0.062 10.80 BAY12-A07 0.633 0.574 0.059 10.28 BAY12-A08 0.588 0.574 0.014 2.44 0.61 7 BAY12-A09 0.594 0.574 0.020 3.48 BAY12-A10 0.596 0.574 0.022 3.83 BAYl2-A11 0.61 8 0.574 0.044 7.67 BAY12-A12 0.61 0 0.574 0.036 6.27 0.605 BAY12-A13 0.595 0.570 0.025 4.39 BAY12-A14 0.596 0.570 0.026 4.56 BAY12-A15 0.612 0.570 0.042 7.37 BAY12-A16 0.607 0.570 0.037 6.49 0.603 Page 6 of 9

1998 IWE Torus inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY13-A01 0.595 0.570 0.025 4.39 BAY13-A02 0.632 0.570 0.062 10.88 BAY 13-A03 0.633 0.570 0.063 11.05 BAY13-AO4 0.601 0.570 0.031 5.44 0.61 5 BAY13-A05 0.597 0.574 0.023 4.01 BAY13-A06 0.639 0.574 0.065 11.32 BAY13-A07 0.641 0.574 0.067 11.67 BAY13-A08 0.603 0.574 0.029 5.05 0.620 BAY13-A09 0.599 0.574 0.025 4.36 BAY13-A10 0.595 0.574 0.021 3.66 BAY13-A11 0.585 0.574 0.01 1 1.92 BAY1&A12 0.585 0.574 0.01 1 1.92 0.591 BAY13-Al3 0.599 0.570 0.029 5.09 BAY13-A14 0.596 0.570 0.026 4.56 BAY13-A15 0.586 0.570 0.01 6 2.81 BAY13-A16 0.585 0.570 0.015 2.63 0.592 BAY14-A01 0.591 0.570 0.021 3.68 BAY14-A02 0.626 0.570 0.056 9.82 BAY14-A03 0.625 0.570 0.055 9.65 BAY14-A04 0.590 0.570 0.020 3.51 0.608 BAY14-A05 0.573 0.574 -0.001 -0.17 BAY14-A06 0.613 0.574 0.039 6.79 BAY14-A07 0.614 0.574 0.040 6.97 BAY14-A08 0.596 0.574 0.022 3.83 0.599 BAY14-A09 0.597 0.574 0.023 4.01 BAY14-A10 0.598 0.574 0.024 4.18 BAY14-A11 0.590 0.574 0.016 2.79 BAY14-A12 0.595 0.574 0.021 3.66 0.595 BAY14-A13 0.594 0.570 0.024 4.21 BAY14-AI4 0.594 0.570 0.024 4.21 BAY14-A15 0.590 0.570 0.020 3.51 BAY14-A16 0.594 0.570 0.024 4.21 0.593 BAY14-A17 0.592 0.566 0.026 4.59 BAY14-Al8 0.593 0.559 0.034 6.08

\

Page 7 of 9

1998 IWE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 BAY15-AO1 0.585 0.570 0.015 2.63 BAY15-A02 0.604 0.570 0.034 5.96 BAY15-A03 0.605 0.570 0.035 6.14 BAY15-A04 0.597 0.570 0.027 4.74 0.598 BAY15-A05 0.589 0.574 0.01 5 2.61 BAY15-A06 0,609 0.574 0.035 6.1 0 BAY15-A07 0.610 0.574 0.036 6.27 BAY15-A08 0.599 0.574 0.025 4.36 0.602 BAY15-A09 0.582 0.574 0.008 1.39 BAY15-A10 0.582 0.574 0.008 1.39 BAY15-Al1 0.607 0.574 0.033 5.75 BAY15-Al2 0.606 0.574 0.032 5.57 0.594 BAY15-Al3 0.584 0.570 0.014 2.46 BAY15-A14 0.580 0.570 0.01 0 1.75 BAY15-A15 0.605 0.570 0.035 6.14 BAY15-A16 0.604 0.570 0.034 5.96 0.593 BAY15-Al7 0.587 0.566 0.021 3.71 BAY15-Al8 0.581 0.559 0.022 3.94 BAY16-A01 0.587 0,570 0.01 7 2.98 BAY16-A02 0.613 0.570 0.043 7.54 BAY16-A03 0.61 5 0.570 0.045 7.89 BAY16-A04 0.601 0.570 0.031 5.44 0.604 BAY16-A05 0.587 0.574 0.013 2.26 BAY16-A06 0.61 6 0.574 0.042 7.32 BAY16-A07 0.61 9 0.574 0.045 7.84 BAY16-A08 0.611 0.574 0.037 6.45 0.608 BAY16-A09 0.601 0.574 0.027 4.70 BAY16-A10 0.607 0.574 0.033 5.75 BAY16-Al1 0.613 0.574 0.039 6.79 BAY16-A12 0.61 0 0.574 0.036 6.27 0.608 BAY16-A13 0.597 0.570 0.027 4.74 BAY16-A14 0.602 0.570 0.032 5.61 BAY 16-A15 0.61 1 0.570 0.041 7.19 BAY16-A16 0.585 0.570 0.01 5 2.63 0.599 Maximum 0.642 0.072 12.632 0.621 Minimum 0.573 -0.001 -0.1 74 0.591 Page 8 of 9

1998 !WE Torus Inspection Report Appendix C: Evaluation of Permenant Grid Locations Location UT Measured Acceptance Margin Margin Ave. Thickness Identifier Thickness Criteria (inch) (percent) Circumferential (inch) (inch) Note 3 Note 4 Stress (inch)

Note 1 Note 2 Note 5 NOTES 1 After sandblasting thickness measurement.

2 General area corrosion acceptance criteria from VYC-1032, Revision 1.

3 = UT measurement - Acceptance Criteria 4 = % Over Acceptance Criteria 5 = ave. for Circ. Stress (measurments along horizontal line).

Page 9 of 9

I V.Y. 1998 ASME SECTION XI SUBSECTION IWE REPORT ON EVALUATION OF TORUS INSPECTIONS APPENDIX D: EVALUATION OF UT DATA FOR GROUP 3 LOCAL AREA INSPECTIONS

~ -~

Appendix IS1 Report No. Location Description inspection Data Screening Results / Comments A Statistics.

TAB No. (Thickness, Inches) 10 YA-UT-112-125 Bay 4: Bottom 8 discrete locations: Row 4A Max. = 0.644" All readings above bottom centerline Plate Thickness (Figure 2.5) Min. = 0.602" min. wall = 0.584" Under Baffle Ave. = 0.623" Plates. No engineering evaluation required.

YA-UT-112-126 Bay 15: 8 discrete locations at Row Max. = 0.599 All readings above bottom centerline Torus Bottom Plate 15A(Figure 2.5) Min. = 0.586 min. wall = 0.584" Thickness Under Ave. = 0.592" Baffle Plates. No engineering evaluation required.

8 discrete locations at Row Max. = 0.61 0" 15B(Figure 2.5) Min. = 0.596" Ave. = 0.61 3" 11 YA-UT-112-127 Bay 7: Local 8 discrete locations adjacent Max. = 0.595" Confirmatory readings performed during indications at to round indication 27" from Min. = 0.592" Torus coating efforts, indications were temporary opening. bottom of opening. Ave. = 0.594" weld repaired as required, see WPC W-NCR17. All readings above bottom centerline min. wall = 0.584".

YA-UT-112-129 11 discrete locations adjacent to gouge at top of Max. = 0.594" No engineering evaluation required.

opening. Min. = 0.589" Ave. = 0.591" 12 (3/31/98) -

Bay 1 Area 1: 3x8" strip of moderate M a . = 0.61 5" All readings above bottom centerline min. wall = 0.584" As-found Local corrosion located 6 from Min. = 0.606 Area UT bottom seam weld and lo" Ave. =0.610 Examination from bay 1611 ring girder. No engineering evaluation required.

Page 1 of 4

v V.Y. 1998 ASME SECTION XI SUBSECTION IWE REPORT ON EVALUATION OF TORUS INSPECTIONS APPENDIX D: EVALUATION OF UT DATA FOR GROUP 3 LOCAL AREA INSPECTIONS Appendix IS1 Report No. Location Description Inspection Data Screening Results / Comments A Statistics.

TAB No. (Thickness, Inches) 13 YA-UT-112-27 Bay2-Areal: Single pit ( was identified Max. = 0.609 All readings above bottom centerline As-found Local previously from under water Min. = 0.591 min. wall = 0.584 Area UT visual coating inspection Ave. =0.606 Examination 9/96). No engineering evaluation required.

6x6 grid located 11-6 toward Torus ID and 18 from mid bay seam weld.

~~

14 YA-UT-112-131 -

Bay 2 Area 2: 4 x 5 area of moderate M a . = 0.574 All readings above code minimum wall YA-UT-112-133 As-found Local corrosion and pitting Min. = 0.567 thickness at this location. See Table 3.1 Area UT previously marked as 93-07, Ave. = 0.571 Permanent grid measurements on the Examination located 20-10 from bottom same average 0.578 seam weld and 9 from bay 2/3 ring girder. No engineering evaluation required.

(6x6 square area, expanded to 12x12 area)

Post-Sandblast.

15 YA-UT-112-26 Bay 5 -Area 1: 9xI 2 area of numerous Max. = 0.602 Note: identified as Bay 5 - Area 2 on YA-UT-112-46 As-found Local small pits and minor Min. = 0.585 As-found Visual Examination (Appendix Area UT corrosion located 43 from Ave. = 0.596 A ,Tab 1)

Examination. bay 516 ring girder and 5 6 Bay 5 -Area 1: from bottom seam weld. All readings above bottom centerline Confirmatory (13 x 15 area 1 grids ) min. wall = 0.584.

Readings No engineering evaluation required.

16 YA-UT-112-25 -

Bay 5 Area 2: Areas of minor oxidation & Max. = 0.599 Identified as Bay 5 - Area 3 on As-found YA-UT-112-46 As-found Local degraded coating 2 6 from Min. = 0.586 Visual Examination (Appendix A ,Tab 1)

Area UT bay 4/5 ring girder and 145 Ave. = 0.596 Examination from bottom seam weld. All readings above bottom centerline Bay 5 - Area 2: (26x26 area 1 grids) min. wall = 0.584.

Confirmatory Readings No engineering evaluation required.

Page 2 of 4

V.Y. 1998 ASME SECTION XI SUBSECTION IWE REPORT ON EVALUATION OF TORUS INSPECTIONS APPENDIX D: EVALUATION OF UT DATA FOR GROUP 3 LOCAL AREA INSPECTIONS Appendix IS1 Report No. Location Description Inspection Data Screening Results / Comments A Statistics.

TAB No. (Thickness, Inches) 17 YA-UT-112-67 Bay 5 - Area 1 60x12 strip of moderate Max. = 0.644 Identified as Bay 1 - Area 1 on As-found YA-UT-112-68 (Inside) corrosion located 5 6 from Min. = 0.583 Visual Examination (Appendix A ,Tab As-found Local bay 516 ring girder along Ave. = 0.613 1)1UT readings from interior surface.

Area UT seam weld. (2 grids) 4 of 180 UT readings at 0.583 are Examination below code min. wall of 0.584 Lowest measured thickness is 99.8% of code min wall.

All readings above bottom acceptance criteria of 0.574. See Table 3.1.

No engineering evaluation required.

18 YA-UT-112-48 Bay 12 -Area 1: 6x6strip of moderate Max. = 0.595 All readings above bottom centerline As-found Local corrosion 21 from bay Min. = 0.590 min. wall = 0.584 Area UT 11/12 ring girder, and 8 8 Ave. = 0.592 Examination. from bottom seam weld. No engineering evaluation required.

Bay 12 - Area 2:

~

19 YA-UT-112-24 24x12 area of minor Max. = 0.61 9 Minimum value of 0.570 is greater YA-UT-112-46 As-found Local corrosion located 6ft. from Min. = 0.570 than acceptance criteria from Table 3.1 YA-UT-112-47 Area UT bay 11/12 ring girder and Ave. = 0.595 for distance of 7 feet from bottom center Examination. approx. 9 0 from bottom of Torus. = 569. Locations of thinnest Bay 12 Area 2: seam weld. (1 grids) readings are oriented in the Confirmatory circumferential direction & may be due Readings (26DL+) to rolling of plates.

Bay 12 Area 2:

Confirmatory No engineering evaluation required.

Readings (A-Scan) 20 (4/1/99) Bay 15-Area 1: 8 x 8 area of moderate M a . = 0.603 All readings above bottom centerline As-found Local corrosion. Located 14 from Min. = 0.597 min. wall = 0.584 Area UT bay 15/14 ring girder Ave. = 0.600 Examination approx. 19-6 from bottom No engineering evaluation required.

seam weld.

(area was previously marked 93-16)

Page 3 of 4

- -r b

V.Y. 1998 ASME SECTION XI SUBSECTION IWE REPORT ON EVALUATION OF TORUS INSPECTIONS APPENDIX D: EVALUATION OF UT DATA FOR GROUP 3 LOCAL AREA INSPECTIONS Appendix Description Inspection Data Screening Results I Comments A Statistics.

TAB No. (Thickness, Inches) 21 (411/99) -

Bay 15 Area 2: 6 x 6 area of moderate Max. = 0.603 Minimum value of 0.543 is greater As-found Local corrosion. Located 6 from Min. = 0.543" than acceptance criteria from Table 3.1 Area UT bay 15/14 ring girder Ave. = 0.597" for distance of 19.0 feet from bottom Examination approx. 19'-10" from bottom center of Torus ( =.534"). Single low seam weld. reading is characterized as less than (area was previously diameter of transducer (.312). Adjacent marked 93-16) measurements are approx. 0.600 No engineering evaluation required.

Page 4 of 4