ML17045A515: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(6 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17045A515
| number = ML17045A515
| issue date = 11/21/2016
| issue date = 11/21/2016
| title = Davis-Besse Nuclear Power Station, Unit 1, Revision 31 to Updated Final Safety Analysis Report, Drawing M-536-00053, Rev 7
| title = Revision 31 to Updated Final Safety Analysis Report, Drawing M-536-00053, Rev 7
| author name =  
| author name =  
| author affiliation = FirstEnergy Nuclear Operating Co
| author affiliation = FirstEnergy Nuclear Operating Co
Line 15: Line 15:
| document type = Drawing, Updated Final Safety Analysis Report (UFSAR)
| document type = Drawing, Updated Final Safety Analysis Report (UFSAR)
| page count = 1
| page count = 1
| revision = 0
}}
}}
=Text=
{{#Wiki_filter:.-------------------------------------------------------------------( FT-RC1A4)
REACTOR COOLANT cA/P LOOP "A' ROSEMOUNT TRANSMITTER EXTERNAL WIRING REACTOR BUILDING PENETRATION FLOW CHANNEL TEST CH-I ON TEST OSI. 0 ( FT-RCIB4)
REACTOR COOLANT cAJp LOOP '8' ROSEMOUNT TRANSMITTER EXTERNAL WIRING REACTOR BUILDING PENETRATION 18 R.C. FLOW LOOP "A' SQUARE ROOT EXTRACTOR REFERENCE stl'Pl y +10V Cl-5-4 R. C. FLOW LOOP 'B' SQUARE ROOT EXTRACTOR Ct-5-7 TR IANGll.AR
<EERATOR
* REW.ATOR R.C. LOOP 'A' }FLDW TO COMPUTER & TO ICS/ll.O PT. A10050, CABINET C5761G, VIA CABLE BUJLDO. REF. DWG' S. E-583, SH.6 ' E-6IOA, SH. 31. R.C. TOTAL FLOW BUFFER AMPLIFIER I C2-9-2 I R.C. TOTAL FLOW TO 1 } COll'UTER AND TO I CSlll.D P S PT.AI0028, CABINET C5161G, VIA CABLE BLULOE. REFERENCE DllG' S E-583, 511.6
* E*610A, SH.31. REFERENCE Sl.l'PLY -10 voe I C2-9-2 I 4 }'*'* s LOOP '8' p FLOW TO COlf'llTER Cl-5-10 REFERENCE DWG.' S 08047555 LEGEND & DRAWING REF. 08047543 EXTERNAL 08047544 EXTERNAL THIS DRAWING IS TIE PROPERTY OF BAILEY IETER CCM'ANY NE ITH&#xa3;R THE DRAWING, NOR REPRODUCTION Cl' IT, Nm INFORMATJON DERIVED FROM IT IS TO BE GIVEN TO OTHERS. NO USE IS TO BE MADE OF IT ltiICH IS m MAY BE INJURIOUS TO BAILEY IETER COlf'ANY.
DB 06-01-12 BABCOCK &c WILCOX DRAWING NUMBER 620-0014 23 02 426 02 THIS DRAWING WAS REDRAWN ON CAD AND SUPERSEDES SlJ3MITTAL
: 5. INC. DUN 02-0540-02-73 REV.DI Ii GEN. UPDATE REVISE 'C57566' TO 'C5756G' PER REVIEW OF 0 rir INI IAL ON FILE II Al REV. Tl, SUBMITTAL
: 5. NOTIF,600695912)
IREORA'llNl NO. D*TE AEYISICOIS llY Ctf'k EMQR .. SCALS: NONE DESIMO -""SAC DATt 6-21c11 DAVIS-BESSE NUCLEAR POWER STATION UNIT NO. 1 SCHEMATIC DIAGRAM REACTOR COOLANT FLOW CHANNEL SUBASSEMBLY "C" CUSTONER1 TOLEDO EDISON COMPANY PLANT* DAVIS-BESSE NUCLEAR, !111T *I CONTRACTING ENG.: BECHTEL a.M.co. JOB HO.* 1220M 0205921.J, CUST .ORDER NO.:
BAILEY METER COMPANY DRAWING NO. 08047580C DFN* IIELEC/1153653.
DGN SIBT NO. NIA ...... T3}}

Latest revision as of 09:27, 16 March 2019

Revision 31 to Updated Final Safety Analysis Report, Drawing M-536-00053, Rev 7
ML17045A515
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 11/21/2016
From:
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17039A594 List: ... further results
References
L-16-322 M-536-00053, Rev 7
Download: ML17045A515 (1)


Text

.-------------------------------------------------------------------( FT-RC1A4)

REACTOR COOLANT cA/P LOOP "A' ROSEMOUNT TRANSMITTER EXTERNAL WIRING REACTOR BUILDING PENETRATION FLOW CHANNEL TEST CH-I ON TEST OSI. 0 ( FT-RCIB4)

REACTOR COOLANT cAJp LOOP '8' ROSEMOUNT TRANSMITTER EXTERNAL WIRING REACTOR BUILDING PENETRATION 18 R.C. FLOW LOOP "A' SQUARE ROOT EXTRACTOR REFERENCE stl'Pl y +10V Cl-5-4 R. C. FLOW LOOP 'B' SQUARE ROOT EXTRACTOR Ct-5-7 TR IANGll.AR

<EERATOR

  • REW.ATOR R.C. LOOP 'A' }FLDW TO COMPUTER & TO ICS/ll.O PT. A10050, CABINET C5761G, VIA CABLE BUJLDO. REF. DWG' S. E-583, SH.6 ' E-6IOA, SH. 31. R.C. TOTAL FLOW BUFFER AMPLIFIER I C2-9-2 I R.C. TOTAL FLOW TO 1 } COll'UTER AND TO I CSlll.D P S PT.AI0028, CABINET C5161G, VIA CABLE BLULOE. REFERENCE DllG' S E-583, 511.6
  • E*610A, SH.31. REFERENCE Sl.l'PLY -10 voe I C2-9-2 I 4 }'*'* s LOOP '8' p FLOW TO COlf'llTER Cl-5-10 REFERENCE DWG.' S 08047555 LEGEND & DRAWING REF. 08047543 EXTERNAL 08047544 EXTERNAL THIS DRAWING IS TIE PROPERTY OF BAILEY IETER CCM'ANY NE ITH£R THE DRAWING, NOR REPRODUCTION Cl' IT, Nm INFORMATJON DERIVED FROM IT IS TO BE GIVEN TO OTHERS. NO USE IS TO BE MADE OF IT ltiICH IS m MAY BE INJURIOUS TO BAILEY IETER COlf'ANY.

DB 06-01-12 BABCOCK &c WILCOX DRAWING NUMBER 620-0014 23 02 426 02 THIS DRAWING WAS REDRAWN ON CAD AND SUPERSEDES SlJ3MITTAL

5. INC. DUN 02-0540-02-73 REV.DI Ii GEN. UPDATE REVISE 'C57566' TO 'C5756G' PER REVIEW OF 0 rir INI IAL ON FILE II Al REV. Tl, SUBMITTAL
5. NOTIF,600695912)

IREORA'llNl NO. D*TE AEYISICOIS llY Ctf'k EMQR .. SCALS: NONE DESIMO -""SAC DATt 6-21c11 DAVIS-BESSE NUCLEAR POWER STATION UNIT NO. 1 SCHEMATIC DIAGRAM REACTOR COOLANT FLOW CHANNEL SUBASSEMBLY "C" CUSTONER1 TOLEDO EDISON COMPANY PLANT* DAVIS-BESSE NUCLEAR, !111T *I CONTRACTING ENG.: BECHTEL a.M.co. JOB HO.* 1220M 0205921.J, CUST .ORDER NO.:

BAILEY METER COMPANY DRAWING NO. 08047580C DFN* IIELEC/1153653.

DGN SIBT NO. NIA ...... T3