W3P89-3072, Responds to Generic Ltr 89-06, Spds. Facility Fully Meets Requirements of NUREG-0737,Suppl 1.Facility SPDS Became Fully Tested,Installed,Accepted & Turned Over to Operations for Use in Feb 1989

From kanterella
(Redirected from W3P89-3072)
Jump to navigation Jump to search
Responds to Generic Ltr 89-06, Spds. Facility Fully Meets Requirements of NUREG-0737,Suppl 1.Facility SPDS Became Fully Tested,Installed,Accepted & Turned Over to Operations for Use in Feb 1989
ML20246P300
Person / Time
Site: Waterford Entergy icon.png
Issue date: 07/11/1989
From: Burski R
LOUISIANA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-NUREG-0737, RTR-NUREG-1342, RTR-NUREG-737, TASK-1.D.2, TASK-TM GL-89-06, GL-89-6, W3P89-3072, NUDOCS 8907200159
Download: ML20246P300 (3)


Text

7 L:.,. e.-

GL 89-06 p

10CFR50.54(f) s I OUIStANA P O W E R & L i G H T. / 317 BARONNE STREET P. O, BOX 60340 NEW ORLEANS, LOUISIANA 70160 (504)595-3100

$r ONSYsNM W3P89-3072 A4.05 July 11, 1989 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 NRC Generic Letter No. 89-06 Task Action Plan Item.I.D.2 -

Safety Parameter Display System

References:

1.

LP&L Letter No. W3P87-1628 dated July 8, 1987 from K.W.

Cook to NRC 2.

NRC Letter (TAC No. 56907) dated August 20, 1987 fr.om J.H. Wilson to J.G. Dewease 3.

LP&L Letter No. W3P88-1341 dated June 30, 1988 from R.F.

Burski to NRC Gentlemen:

The subject Generic Letter requested that licensees / applicants furnish one of the following statements.with regard to the implementation status of their SPDS:

1.

Certification that the SPDS fully meets the requirements of NUREG-0737, Supplement 1, taking inte account the information provided in NUREG-1342.

Licensees should maintain supporting documentation for three years, including the completed checklist and photographs used to establish SPDS implementation status; 2.

Certification that the SPDS will be modified to fully meet the requirements of NUREG-0737, Supplement 1, taking into account the information provided in NUREG-1342. The implementation schedule for the modifications shall be provided. Licensees should maintain supporting documentation for three years, including the completed checklist and photographs used to establish SPDS implementation status; or 8

8907200159 090711 PDR ADOCK 05000382A P

PNU j NS140197C "AN EQUAL OPPORTUNITY EMPLOYER" Il'0

f.*

NRC Generic Letter No. 89-06 Page 2 July 11, 1989 3.

If a certification cannot be provided, the licensee shall provide a discussion of the reasons for that finding and a discussion of the compen-satory action the licensee intends to take or has taken.

Accordingly, the purpose of this letter is to document that the Waterford 3 SPDS (as modified in accordance with the functional design specification submitted in the Reference 1 letter and reviewed in the safety evaluation report issued in the Reference 2 letter) fully meets the requirements of NUREG-0737, Supplement 1, taking into account the information provided in RUREG-1342. The modified Waterford 3 SPDS became fully tested, installed, accepte'd, and turned over to plant operations for use in February, 1989 in accordane.e with the schedules provided to you in the Reference 3 letter.

As requested, the supporting documentation, including the completed checklist and photographs used to establish SPDS implementation status will be maintained in the Waterford 3 Records Center for a minimum of three years.

(Note:

3" x 5" sized photographs are currently in the files. They will be replaced with the requested 8" x 10" sized photographs which are currently on order.)

Should you have any questions or comments on this matter, please contact T.J. Gaudet at (504) 464-3325.

Very truly yours, vw R.F. Burski Manager Nuclear Safety & Regulatory Affairs RFB/TJG/ssf cc: Messrs. R.D. Martin, NRC Region IV F.J. Hebdon, NRC-NRR D.L. Wigginton, NRC-NRR NRC Resident Inspectors Office E.L. Blake W.M. Stevenson l

l NS140197C L_ __ _

p l'., _ ' 4I *

s UNITED STATES OF AKERICA NUCLEAR REGULATORY COMMISSION In the matter of

)

)

Louisiana Power & Light Company

) Docket No. 50-382 Waterford 3 Steam Electric Station

)

AFFIDAVIT R.F. Burski, being duly sworn, hereby deposes and says that he is Nuclear Safety and Regulatory Affairs Manager of Louisiana Power & Light Company; that he is duly authorized to sign and file with the Nuclear Regulatory Commission this response to NRC Generic Letter No. 89-06; that he is familiar with the content thereof; and that the matters set forth therein are true and correct to the best of his knowledge, information and belief.

i f

./

R.F. Et(rski Manager Nuclear Safety & Regulatory Affairs STATE OF LOUISIANA)

) ss PARISil 0F ORLEANS )

Subscribed and sworn to before me, a Notary Publ in nd for the Parish and State above named this

// d day of L

1989.

(/ [

m tary Public My Commission expires

/j I

/~

)

)

i i________.______.____