U-602463, Application for Amend to License NPF-62,submitting Rev 1 to TS Bases,Per TS 5.5.11, TS Bases Control Program
ML20085N060 | |
Person / Time | |
---|---|
Site: | Clinton |
Issue date: | 06/23/1995 |
From: | Phares R ILLINOIS POWER CO. |
To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
Shared Package | |
ML20085N061 | List: |
References | |
U-602463, NUDOCS 9506300023 | |
Download: ML20085N060 (2) | |
Similar Documents at Clinton | |
---|---|
Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARU-603247, Application for Amend to License NPF-62,re Various Administrative Changes Involving Deletion of Certain License Conditions Currently Contained in OL That Are Obsolete & No Longer Apply1999-08-23023 August 1999
[Table view]Application for Amend to License NPF-62,re Various Administrative Changes Involving Deletion of Certain License Conditions Currently Contained in OL That Are Obsolete & No Longer Apply ML20210K8281999-07-23023 July 1999 Application for Amend to License NPF-62,consenting to License Transfer & Approving Conforming Administrative License Amend U-603131, Application for Amend to License NPF-62,changing CPS Design Requirements for Physical Protection from Tornado Missiles for safety-related Equipment,As Described in Plant Usar. Revised USAR Pages,Encl1999-03-0101 March 1999 Application for Amend to License NPF-62,changing CPS Design Requirements for Physical Protection from Tornado Missiles for safety-related Equipment,As Described in Plant Usar. Revised USAR Pages,Encl U-603146, Application for Amend to License NPF-62,changing TS Table 3.3.8.1-1 to Revise Allowable Values for Degraded Voltage Relay Reset & Dropout Setpoints as Specified Per Items 1.c, 1.d,2.c & 2.d of Table1999-01-20020 January 1999 Application for Amend to License NPF-62,changing TS Table 3.3.8.1-1 to Revise Allowable Values for Degraded Voltage Relay Reset & Dropout Setpoints as Specified Per Items 1.c, 1.d,2.c & 2.d of Table U-603032, Application for Amend to License NPF-62,adding TS LCO 3.6.1.9, FW LCS (FWLCS) for Implementation of FWLCS Mode of RHR Sys1998-10-23023 October 1998 Application for Amend to License NPF-62,adding TS LCO 3.6.1.9, FW LCS (FWLCS) for Implementation of FWLCS Mode of RHR Sys ML20154H8011998-10-0505 October 1998 Application for Amend to License NPF-62,revising TS 5.5.13 to Allow Next Scheduled Performance of LLRT of Primary Containment Penetration for RPV Head Spray Piping (IMC-042) to Be Deferred Until Seventh Refueling Outage (RF-7) U-603067, Application for Amend to License NPF-65,revising Acceptance Criteria for Meeting ready-to-load Requirement Denoted by TS SR 3.8.1.17 for Division 3 DG1998-08-24024 August 1998 Application for Amend to License NPF-65,revising Acceptance Criteria for Meeting ready-to-load Requirement Denoted by TS SR 3.8.1.17 for Division 3 DG U-603030, Application for Amend to License NPF-62,partially Reducing Load at Which DGs Are Required to Be Tested Per Affected SRs in Order to Reduce Stress & Wear on Machines While Still Sufficiently Challenging Machines to Confirm Operability1998-08-17017 August 1998 Application for Amend to License NPF-62,partially Reducing Load at Which DGs Are Required to Be Tested Per Affected SRs in Order to Reduce Stress & Wear on Machines While Still Sufficiently Challenging Machines to Confirm Operability U-603043, Application for Amend to License NPF-62,revising Acceptance Criteria of SRs 3.8.1.7,3.8.1.12,3.8.1.15 & 3.8.1.201998-07-31031 July 1998 Application for Amend to License NPF-62,revising Acceptance Criteria of SRs 3.8.1.7,3.8.1.12,3.8.1.15 & 3.8.1.20 U-602983, Application for Amend to License NPF-62,proposing Mod to Auxiliary Power Sys,Including Associated Changes Proposed for CPS Usar.Revised USAR Pages,Encl1998-05-20020 May 1998 Application for Amend to License NPF-62,proposing Mod to Auxiliary Power Sys,Including Associated Changes Proposed for CPS Usar.Revised USAR Pages,Encl U-602972, Application for Amend to License NPF-62,incorporating Requirements for Static Var Compensator (SVC) Protection Sys Under New TS1998-05-0404 May 1998 Application for Amend to License NPF-62,incorporating Requirements for Static Var Compensator (SVC) Protection Sys Under New TS U-602982, Application for Amend to License NPF-62,consisting of Proposed Changes Necessary to Implement Mgt Changes Occurring in Operations Organization at Plant1998-04-27027 April 1998 Application for Amend to License NPF-62,consisting of Proposed Changes Necessary to Implement Mgt Changes Occurring in Operations Organization at Plant U-602796, Application for Amend to License NPF-62,requesting Temporary Partial Exemption to 10CFR50,App A,General Design Criteria 17 Re Offsite Circuit Condition. Condition1997-07-22022 July 1997 Application for Amend to License NPF-62,requesting Temporary Partial Exemption to 10CFR50,App A,General Design Criteria 17 Re Offsite Circuit Condition. Condition ML20137K8271997-04-0101 April 1997 Application for Amend to License NPF-62,consisting of TS Table 3.3.8.1-1, Loss of Power Instrumentation U-602675, Application for Amend to License NPF-62,requesting Consent to Transfer Minority Ownership1996-12-13013 December 1996 Application for Amend to License NPF-62,requesting Consent to Transfer Minority Ownership U-602657, Application for Amend to License NPF-62 to Revise Table 3.3.8.1-1, Loss of Power Instrumentation, by Dividing Function, Degraded Voltage - 4.16 Kv Basis, Into Two Separate Items1996-11-19019 November 1996 Application for Amend to License NPF-62 to Revise Table 3.3.8.1-1, Loss of Power Instrumentation, by Dividing Function, Degraded Voltage - 4.16 Kv Basis, Into Two Separate Items ML20129E5351996-10-17017 October 1996 Application for Amend to License NPF-62,requesting Consent to Proposed Transfer of Soyland Power Cooperative 13.21% Minority Ownership Interest in Plant to Illinova Power Inc ML20128K0351996-10-0404 October 1996 Revised Application for Amend to License NPF-62,adding Action Statement & Note to TS 3.3.8.1 Requiring Restoration of Inoperable Degraded Voltage Relay U-602624, Application for Amend to License NPF-62,changing TS to Incorporate Revised SLMCPR as Calculated by GE for CPS Cycle 71996-08-15015 August 1996 Application for Amend to License NPF-62,changing TS to Incorporate Revised SLMCPR as Calculated by GE for CPS Cycle 7 U-602587, Application for Amend to License NPF-62,allowing Removal of Inclined Fuel Transfer Sys Primary Containment Blind Flange While Primary Containment Required to Be Operable1996-06-28028 June 1996 Application for Amend to License NPF-62,allowing Removal of Inclined Fuel Transfer Sys Primary Containment Blind Flange While Primary Containment Required to Be Operable ML20113A8781996-06-21021 June 1996 Application for Amend to License NPF-62,allowing Utilization of RWP or Equivalent to Control Entry Into High Radiation Area,Clarifying Example Given in TS of Individuals Qualified in Radiation Protection Procedures U-602565, Application for Amend to License NPF-62,implementing 10CFR50,App J-Option B1996-05-0101 May 1996 Application for Amend to License NPF-62,implementing 10CFR50,App J-Option B U-602569, Application for Amend to License NPF-62,revising Listed TS to Eliminate Core Alterations as Applicable Condition for Which Associated LCO Must Be Met1996-04-19019 April 1996 Application for Amend to License NPF-62,revising Listed TS to Eliminate Core Alterations as Applicable Condition for Which Associated LCO Must Be Met U-602522, Application for Amend to License NPF-62,changing TS 3.3.4.1, End of Cycle Recirculation Pump Trip Instrumentation, to Delete SR 3.3.4.1.6 Which Requires RPT Breaker Interruption Time to Be Determined at Least Once Per 60 Months1996-02-22022 February 1996 Application for Amend to License NPF-62,changing TS 3.3.4.1, End of Cycle Recirculation Pump Trip Instrumentation, to Delete SR 3.3.4.1.6 Which Requires RPT Breaker Interruption Time to Be Determined at Least Once Per 60 Months U-602551, Application for Amend to License NPF-62,changing TS 3.4.11, RCS P/T Limits, to Incorporate Specific P/T Limits for Bottom Head Region of Rv Separate & Apart from Core Beltline Region of Rv1996-02-22022 February 1996 Application for Amend to License NPF-62,changing TS 3.4.11, RCS P/T Limits, to Incorporate Specific P/T Limits for Bottom Head Region of Rv Separate & Apart from Core Beltline Region of Rv U-602549, Application for Amend to License NPF-62,proposing to Revise TS 3.6.5.1, Drywell, to Allow Drywell Bypass Leakage Tests to Be Performed at Intervals of Up to Ten Yrs Based on Demonstrated Performance of Drywell Barrier1996-02-22022 February 1996 Application for Amend to License NPF-62,proposing to Revise TS 3.6.5.1, Drywell, to Allow Drywell Bypass Leakage Tests to Be Performed at Intervals of Up to Ten Yrs Based on Demonstrated Performance of Drywell Barrier U-602554, Application for Amend to License NPF-62,deleting SR 3.3.8.1.1 Which Requires Channel Check for Loss of Power Instrumentation & Change TS Table 3.3.8.1-1 to Change Allowable Value for Degraded Voltage Function1996-02-22022 February 1996 Application for Amend to License NPF-62,deleting SR 3.3.8.1.1 Which Requires Channel Check for Loss of Power Instrumentation & Change TS Table 3.3.8.1-1 to Change Allowable Value for Degraded Voltage Function U-602508, Application for Amend to License NPF-62,requesting Various Proposed Changes to TS for Instrumentation Associated W/High Pressure Core Spray Sys,Reactor Core Isolation Cooling Sys & Residual Heat Removal Sys1995-12-14014 December 1995 Application for Amend to License NPF-62,requesting Various Proposed Changes to TS for Instrumentation Associated W/High Pressure Core Spray Sys,Reactor Core Isolation Cooling Sys & Residual Heat Removal Sys U-602520, Application for Amend to License NPF-62,revising TS 3.3.1.1, RPS Instrumentation & TS 3.3.6.1, Primary Containment Dwl Isolation Instrumentation, to Eliminate Periodic Response Time Testing of Analog Trip Modules1995-12-14014 December 1995 Application for Amend to License NPF-62,revising TS 3.3.1.1, RPS Instrumentation & TS 3.3.6.1, Primary Containment Dwl Isolation Instrumentation, to Eliminate Periodic Response Time Testing of Analog Trip Modules U-602499, Application for Amend to License NPF-62,requesting Proposed Change to TS 3.4.2, Flow Control Valves, to Delete Requirement to Verify Average Rate of Movement of Each Reactor Recirculation Sys1995-12-14014 December 1995 Application for Amend to License NPF-62,requesting Proposed Change to TS 3.4.2, Flow Control Valves, to Delete Requirement to Verify Average Rate of Movement of Each Reactor Recirculation Sys ML20094D1971995-10-27027 October 1995 Application for Amend to License NPF-62,consisting of Changes to TS 3.1.3 to Include 25% Surveillance Overrun Allowed by LCO 3.0.2 Into Allowances of Surveillance Notes for Control Rod Notch Testing Per SR 3.1.3.2 & SR 3.1.3.3 ML20094D2081995-10-27027 October 1995 Application for Amend to License NPF-62,consisting of Changes to TS 5.2.2.e to Revise Requirements for Controls on Working Hs of Unit Staff That Perform SR Functions U-602463, Application for Amend to License NPF-62,submitting Rev 1 to TS Bases,Per TS 5.5.11, TS Bases Control Program1995-06-23023 June 1995 Application for Amend to License NPF-62,submitting Rev 1 to TS Bases,Per TS 5.5.11, TS Bases Control Program U-602454, Application for Amend to License NPF-62,incorporating Description of Exclusion Area Boundary1995-06-0909 June 1995 Application for Amend to License NPF-62,incorporating Description of Exclusion Area Boundary U-602417, Application for Amend to License NPF-62,changing TS 3.8.2, 3.8.5 & 3.8.8 to Revise Operability Requirements for Div 3 DG & Divs 3 & 4 Batteries,Battery Chargers & Inverters to Apply Only When HPCS Required to Be Operable1995-02-14014 February 1995 Application for Amend to License NPF-62,changing TS 3.8.2, 3.8.5 & 3.8.8 to Revise Operability Requirements for Div 3 DG & Divs 3 & 4 Batteries,Battery Chargers & Inverters to Apply Only When HPCS Required to Be Operable U-602406, Application for Amend to License NPF-62,changing TS 3.3.2.1, Control Rod Block Instrumentation to Revise Two SRs & Associated Notes for Rod Withdrawal Limiter Mode of Rod Pattern Control Sys1995-02-10010 February 1995 Application for Amend to License NPF-62,changing TS 3.3.2.1, Control Rod Block Instrumentation to Revise Two SRs & Associated Notes for Rod Withdrawal Limiter Mode of Rod Pattern Control Sys U-602376, Application for Amend to License NPF-62,eliminating Selected Response Time Testing Requirements1995-01-27027 January 1995 Application for Amend to License NPF-62,eliminating Selected Response Time Testing Requirements ML20078L8831994-11-18018 November 1994 Application for Amend to License NPF-62,requesting Revision of CPS TS for Conversion to Improved TS Per Guidance Provided by NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 1992 U-602364, Application for Amend to License NPF-62,providing Final Rev to TS by Converting to Improved TS Per NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 19921994-10-31031 October 1994 Application for Amend to License NPF-62,providing Final Rev to TS by Converting to Improved TS Per NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 1992 U-602297, Application for Amend to License NPF-62,proposing Changes to Ts,Eliminating Requirement to Perform Manual Testing of solid-state Logic Independently from self-test Sys1994-08-12012 August 1994 Application for Amend to License NPF-62,proposing Changes to Ts,Eliminating Requirement to Perform Manual Testing of solid-state Logic Independently from self-test Sys U-602320, Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.2.2, Drywell Bypass Leakage, to Allow Drywell Bypass Leakage Rate Tests to Be Performed at Intervals as Long as Ten Years1994-08-12012 August 1994 Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.2.2, Drywell Bypass Leakage, to Allow Drywell Bypass Leakage Rate Tests to Be Performed at Intervals as Long as Ten Years U-602316, Application for Amend to License NPF-62,requesting Enforcement Discretion by NRC Re TS Requirement for Accelerated Testing of Standby Emergency Diesel Generators1994-08-0505 August 1994 Application for Amend to License NPF-62,requesting Enforcement Discretion by NRC Re TS Requirement for Accelerated Testing of Standby Emergency Diesel Generators U-602303, Application for Amend to License NPF-62,changing TS 3/4.4.3.1, Reactor Coolant Sys Leakage-Leakage Detection Sys1994-06-20020 June 1994 Application for Amend to License NPF-62,changing TS 3/4.4.3.1, Reactor Coolant Sys Leakage-Leakage Detection Sys U-602272, Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.1.8,such That 36-inch Isolation Valve Leak Rate Measurement Would Be Performed at Least Once Per 18 Months, Providing Valves Remain Closed During That Period1994-06-13013 June 1994 Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.1.8,such That 36-inch Isolation Valve Leak Rate Measurement Would Be Performed at Least Once Per 18 Months, Providing Valves Remain Closed During That Period ML20029C7811994-04-18018 April 1994 Application for Amend to License NPF-62,revising TS 3/4.6.6.3, SGTS & 3/4.7.2, CR Ventilation Sys to Update Rev of ASTM Std Utilized to Periodically Perform Lab Testing of Charcoal Adsorber Samples ML20029C7941994-04-18018 April 1994 Application for Amend to License NPF-62,revising TS 3/4.1.3.1,3/4.1.3.2 & 3/4.10.2 as follow-up to Util 930416 Application to Correct Noted Surveillance Number Refs to Be Consistent W/License Amend 81 Issued 930715 JSP-079-94, Application for Amend to License NPF-62,revising TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys, in Response to Inoperability of Drywell Floor Drain Sump Flow Rate Monitoring Instrumentation1994-02-25025 February 1994 Application for Amend to License NPF-62,revising TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys, in Response to Inoperability of Drywell Floor Drain Sump Flow Rate Monitoring Instrumentation U-602192, Application for Amend to License NPF-62,changing Tech Specs 3.3.2, Instrumentation-Containment & Reactor Vessel Isolation Control Sys & 3.6.5, Drywell Post-LOCA Vacuum Relief Valves1993-12-10010 December 1993 Application for Amend to License NPF-62,changing Tech Specs 3.3.2, Instrumentation-Containment & Reactor Vessel Isolation Control Sys & 3.6.5, Drywell Post-LOCA Vacuum Relief Valves JSP-505-93, Application for Amend to License NPF-62,chnaging Tech Spec 3/4.8.1.1, AC Sources-Operating, Including Requirement of DGs to Insp in Accordance W/Mfg Recommendations for Class of Standby Svc1993-11-0404 November 1993 Application for Amend to License NPF-62,chnaging Tech Spec 3/4.8.1.1, AC Sources-Operating, Including Requirement of DGs to Insp in Accordance W/Mfg Recommendations for Class of Standby Svc JSP-504-93, Application for Amend to License NPF-62,changing Tech Spec 3/4.8.2.1, DC Sources-Operating1993-11-0404 November 1993 Application for Amend to License NPF-62,changing Tech Spec 3/4.8.2.1, DC Sources-Operating 1999-08-23 Category:TEXT-LICENSE APPLICATIONS & PERMITS MONTHYEARU-603247, Application for Amend to License NPF-62,re Various Administrative Changes Involving Deletion of Certain License Conditions Currently Contained in OL That Are Obsolete & No Longer Apply1999-08-23023 August 1999
[Table view]Application for Amend to License NPF-62,re Various Administrative Changes Involving Deletion of Certain License Conditions Currently Contained in OL That Are Obsolete & No Longer Apply ML20210K8281999-07-23023 July 1999 Application for Amend to License NPF-62,consenting to License Transfer & Approving Conforming Administrative License Amend U-603131, Application for Amend to License NPF-62,changing CPS Design Requirements for Physical Protection from Tornado Missiles for safety-related Equipment,As Described in Plant Usar. Revised USAR Pages,Encl1999-03-0101 March 1999 Application for Amend to License NPF-62,changing CPS Design Requirements for Physical Protection from Tornado Missiles for safety-related Equipment,As Described in Plant Usar. Revised USAR Pages,Encl U-603146, Application for Amend to License NPF-62,changing TS Table 3.3.8.1-1 to Revise Allowable Values for Degraded Voltage Relay Reset & Dropout Setpoints as Specified Per Items 1.c, 1.d,2.c & 2.d of Table1999-01-20020 January 1999 Application for Amend to License NPF-62,changing TS Table 3.3.8.1-1 to Revise Allowable Values for Degraded Voltage Relay Reset & Dropout Setpoints as Specified Per Items 1.c, 1.d,2.c & 2.d of Table U-603032, Application for Amend to License NPF-62,adding TS LCO 3.6.1.9, FW LCS (FWLCS) for Implementation of FWLCS Mode of RHR Sys1998-10-23023 October 1998 Application for Amend to License NPF-62,adding TS LCO 3.6.1.9, FW LCS (FWLCS) for Implementation of FWLCS Mode of RHR Sys ML20154H8011998-10-0505 October 1998 Application for Amend to License NPF-62,revising TS 5.5.13 to Allow Next Scheduled Performance of LLRT of Primary Containment Penetration for RPV Head Spray Piping (IMC-042) to Be Deferred Until Seventh Refueling Outage (RF-7) U-603067, Application for Amend to License NPF-65,revising Acceptance Criteria for Meeting ready-to-load Requirement Denoted by TS SR 3.8.1.17 for Division 3 DG1998-08-24024 August 1998 Application for Amend to License NPF-65,revising Acceptance Criteria for Meeting ready-to-load Requirement Denoted by TS SR 3.8.1.17 for Division 3 DG U-603030, Application for Amend to License NPF-62,partially Reducing Load at Which DGs Are Required to Be Tested Per Affected SRs in Order to Reduce Stress & Wear on Machines While Still Sufficiently Challenging Machines to Confirm Operability1998-08-17017 August 1998 Application for Amend to License NPF-62,partially Reducing Load at Which DGs Are Required to Be Tested Per Affected SRs in Order to Reduce Stress & Wear on Machines While Still Sufficiently Challenging Machines to Confirm Operability U-603043, Application for Amend to License NPF-62,revising Acceptance Criteria of SRs 3.8.1.7,3.8.1.12,3.8.1.15 & 3.8.1.201998-07-31031 July 1998 Application for Amend to License NPF-62,revising Acceptance Criteria of SRs 3.8.1.7,3.8.1.12,3.8.1.15 & 3.8.1.20 U-602983, Application for Amend to License NPF-62,proposing Mod to Auxiliary Power Sys,Including Associated Changes Proposed for CPS Usar.Revised USAR Pages,Encl1998-05-20020 May 1998 Application for Amend to License NPF-62,proposing Mod to Auxiliary Power Sys,Including Associated Changes Proposed for CPS Usar.Revised USAR Pages,Encl U-602972, Application for Amend to License NPF-62,incorporating Requirements for Static Var Compensator (SVC) Protection Sys Under New TS1998-05-0404 May 1998 Application for Amend to License NPF-62,incorporating Requirements for Static Var Compensator (SVC) Protection Sys Under New TS U-602982, Application for Amend to License NPF-62,consisting of Proposed Changes Necessary to Implement Mgt Changes Occurring in Operations Organization at Plant1998-04-27027 April 1998 Application for Amend to License NPF-62,consisting of Proposed Changes Necessary to Implement Mgt Changes Occurring in Operations Organization at Plant U-602796, Application for Amend to License NPF-62,requesting Temporary Partial Exemption to 10CFR50,App A,General Design Criteria 17 Re Offsite Circuit Condition. Condition1997-07-22022 July 1997 Application for Amend to License NPF-62,requesting Temporary Partial Exemption to 10CFR50,App A,General Design Criteria 17 Re Offsite Circuit Condition. Condition ML20137K8271997-04-0101 April 1997 Application for Amend to License NPF-62,consisting of TS Table 3.3.8.1-1, Loss of Power Instrumentation U-602675, Application for Amend to License NPF-62,requesting Consent to Transfer Minority Ownership1996-12-13013 December 1996 Application for Amend to License NPF-62,requesting Consent to Transfer Minority Ownership U-602657, Application for Amend to License NPF-62 to Revise Table 3.3.8.1-1, Loss of Power Instrumentation, by Dividing Function, Degraded Voltage - 4.16 Kv Basis, Into Two Separate Items1996-11-19019 November 1996 Application for Amend to License NPF-62 to Revise Table 3.3.8.1-1, Loss of Power Instrumentation, by Dividing Function, Degraded Voltage - 4.16 Kv Basis, Into Two Separate Items ML20129E5351996-10-17017 October 1996 Application for Amend to License NPF-62,requesting Consent to Proposed Transfer of Soyland Power Cooperative 13.21% Minority Ownership Interest in Plant to Illinova Power Inc ML20128K0351996-10-0404 October 1996 Revised Application for Amend to License NPF-62,adding Action Statement & Note to TS 3.3.8.1 Requiring Restoration of Inoperable Degraded Voltage Relay U-602624, Application for Amend to License NPF-62,changing TS to Incorporate Revised SLMCPR as Calculated by GE for CPS Cycle 71996-08-15015 August 1996 Application for Amend to License NPF-62,changing TS to Incorporate Revised SLMCPR as Calculated by GE for CPS Cycle 7 U-602587, Application for Amend to License NPF-62,allowing Removal of Inclined Fuel Transfer Sys Primary Containment Blind Flange While Primary Containment Required to Be Operable1996-06-28028 June 1996 Application for Amend to License NPF-62,allowing Removal of Inclined Fuel Transfer Sys Primary Containment Blind Flange While Primary Containment Required to Be Operable ML20113A8781996-06-21021 June 1996 Application for Amend to License NPF-62,allowing Utilization of RWP or Equivalent to Control Entry Into High Radiation Area,Clarifying Example Given in TS of Individuals Qualified in Radiation Protection Procedures U-602565, Application for Amend to License NPF-62,implementing 10CFR50,App J-Option B1996-05-0101 May 1996 Application for Amend to License NPF-62,implementing 10CFR50,App J-Option B U-602569, Application for Amend to License NPF-62,revising Listed TS to Eliminate Core Alterations as Applicable Condition for Which Associated LCO Must Be Met1996-04-19019 April 1996 Application for Amend to License NPF-62,revising Listed TS to Eliminate Core Alterations as Applicable Condition for Which Associated LCO Must Be Met U-602549, Application for Amend to License NPF-62,proposing to Revise TS 3.6.5.1, Drywell, to Allow Drywell Bypass Leakage Tests to Be Performed at Intervals of Up to Ten Yrs Based on Demonstrated Performance of Drywell Barrier1996-02-22022 February 1996 Application for Amend to License NPF-62,proposing to Revise TS 3.6.5.1, Drywell, to Allow Drywell Bypass Leakage Tests to Be Performed at Intervals of Up to Ten Yrs Based on Demonstrated Performance of Drywell Barrier U-602522, Application for Amend to License NPF-62,changing TS 3.3.4.1, End of Cycle Recirculation Pump Trip Instrumentation, to Delete SR 3.3.4.1.6 Which Requires RPT Breaker Interruption Time to Be Determined at Least Once Per 60 Months1996-02-22022 February 1996 Application for Amend to License NPF-62,changing TS 3.3.4.1, End of Cycle Recirculation Pump Trip Instrumentation, to Delete SR 3.3.4.1.6 Which Requires RPT Breaker Interruption Time to Be Determined at Least Once Per 60 Months U-602554, Application for Amend to License NPF-62,deleting SR 3.3.8.1.1 Which Requires Channel Check for Loss of Power Instrumentation & Change TS Table 3.3.8.1-1 to Change Allowable Value for Degraded Voltage Function1996-02-22022 February 1996 Application for Amend to License NPF-62,deleting SR 3.3.8.1.1 Which Requires Channel Check for Loss of Power Instrumentation & Change TS Table 3.3.8.1-1 to Change Allowable Value for Degraded Voltage Function U-602551, Application for Amend to License NPF-62,changing TS 3.4.11, RCS P/T Limits, to Incorporate Specific P/T Limits for Bottom Head Region of Rv Separate & Apart from Core Beltline Region of Rv1996-02-22022 February 1996 Application for Amend to License NPF-62,changing TS 3.4.11, RCS P/T Limits, to Incorporate Specific P/T Limits for Bottom Head Region of Rv Separate & Apart from Core Beltline Region of Rv U-602520, Application for Amend to License NPF-62,revising TS 3.3.1.1, RPS Instrumentation & TS 3.3.6.1, Primary Containment Dwl Isolation Instrumentation, to Eliminate Periodic Response Time Testing of Analog Trip Modules1995-12-14014 December 1995 Application for Amend to License NPF-62,revising TS 3.3.1.1, RPS Instrumentation & TS 3.3.6.1, Primary Containment Dwl Isolation Instrumentation, to Eliminate Periodic Response Time Testing of Analog Trip Modules U-602499, Application for Amend to License NPF-62,requesting Proposed Change to TS 3.4.2, Flow Control Valves, to Delete Requirement to Verify Average Rate of Movement of Each Reactor Recirculation Sys1995-12-14014 December 1995 Application for Amend to License NPF-62,requesting Proposed Change to TS 3.4.2, Flow Control Valves, to Delete Requirement to Verify Average Rate of Movement of Each Reactor Recirculation Sys U-602508, Application for Amend to License NPF-62,requesting Various Proposed Changes to TS for Instrumentation Associated W/High Pressure Core Spray Sys,Reactor Core Isolation Cooling Sys & Residual Heat Removal Sys1995-12-14014 December 1995 Application for Amend to License NPF-62,requesting Various Proposed Changes to TS for Instrumentation Associated W/High Pressure Core Spray Sys,Reactor Core Isolation Cooling Sys & Residual Heat Removal Sys ML20094D1971995-10-27027 October 1995 Application for Amend to License NPF-62,consisting of Changes to TS 3.1.3 to Include 25% Surveillance Overrun Allowed by LCO 3.0.2 Into Allowances of Surveillance Notes for Control Rod Notch Testing Per SR 3.1.3.2 & SR 3.1.3.3 ML20094D2081995-10-27027 October 1995 Application for Amend to License NPF-62,consisting of Changes to TS 5.2.2.e to Revise Requirements for Controls on Working Hs of Unit Staff That Perform SR Functions U-602463, Application for Amend to License NPF-62,submitting Rev 1 to TS Bases,Per TS 5.5.11, TS Bases Control Program1995-06-23023 June 1995 Application for Amend to License NPF-62,submitting Rev 1 to TS Bases,Per TS 5.5.11, TS Bases Control Program U-602454, Application for Amend to License NPF-62,incorporating Description of Exclusion Area Boundary1995-06-0909 June 1995 Application for Amend to License NPF-62,incorporating Description of Exclusion Area Boundary U-602417, Application for Amend to License NPF-62,changing TS 3.8.2, 3.8.5 & 3.8.8 to Revise Operability Requirements for Div 3 DG & Divs 3 & 4 Batteries,Battery Chargers & Inverters to Apply Only When HPCS Required to Be Operable1995-02-14014 February 1995 Application for Amend to License NPF-62,changing TS 3.8.2, 3.8.5 & 3.8.8 to Revise Operability Requirements for Div 3 DG & Divs 3 & 4 Batteries,Battery Chargers & Inverters to Apply Only When HPCS Required to Be Operable U-602406, Application for Amend to License NPF-62,changing TS 3.3.2.1, Control Rod Block Instrumentation to Revise Two SRs & Associated Notes for Rod Withdrawal Limiter Mode of Rod Pattern Control Sys1995-02-10010 February 1995 Application for Amend to License NPF-62,changing TS 3.3.2.1, Control Rod Block Instrumentation to Revise Two SRs & Associated Notes for Rod Withdrawal Limiter Mode of Rod Pattern Control Sys U-602376, Application for Amend to License NPF-62,eliminating Selected Response Time Testing Requirements1995-01-27027 January 1995 Application for Amend to License NPF-62,eliminating Selected Response Time Testing Requirements ML20078L8831994-11-18018 November 1994 Application for Amend to License NPF-62,requesting Revision of CPS TS for Conversion to Improved TS Per Guidance Provided by NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 1992 U-602364, Application for Amend to License NPF-62,providing Final Rev to TS by Converting to Improved TS Per NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 19921994-10-31031 October 1994 Application for Amend to License NPF-62,providing Final Rev to TS by Converting to Improved TS Per NUREG-1434, Improved BWR-6 TS, Rev 0,dated Sept 1992 U-602320, Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.2.2, Drywell Bypass Leakage, to Allow Drywell Bypass Leakage Rate Tests to Be Performed at Intervals as Long as Ten Years1994-08-12012 August 1994 Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.2.2, Drywell Bypass Leakage, to Allow Drywell Bypass Leakage Rate Tests to Be Performed at Intervals as Long as Ten Years U-602297, Application for Amend to License NPF-62,proposing Changes to Ts,Eliminating Requirement to Perform Manual Testing of solid-state Logic Independently from self-test Sys1994-08-12012 August 1994 Application for Amend to License NPF-62,proposing Changes to Ts,Eliminating Requirement to Perform Manual Testing of solid-state Logic Independently from self-test Sys U-602316, Application for Amend to License NPF-62,requesting Enforcement Discretion by NRC Re TS Requirement for Accelerated Testing of Standby Emergency Diesel Generators1994-08-0505 August 1994 Application for Amend to License NPF-62,requesting Enforcement Discretion by NRC Re TS Requirement for Accelerated Testing of Standby Emergency Diesel Generators U-602303, Application for Amend to License NPF-62,changing TS 3/4.4.3.1, Reactor Coolant Sys Leakage-Leakage Detection Sys1994-06-20020 June 1994 Application for Amend to License NPF-62,changing TS 3/4.4.3.1, Reactor Coolant Sys Leakage-Leakage Detection Sys U-602272, Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.1.8,such That 36-inch Isolation Valve Leak Rate Measurement Would Be Performed at Least Once Per 18 Months, Providing Valves Remain Closed During That Period1994-06-13013 June 1994 Application for Amend to License NPF-62,proposing Changes to TS 3/4.6.1.8,such That 36-inch Isolation Valve Leak Rate Measurement Would Be Performed at Least Once Per 18 Months, Providing Valves Remain Closed During That Period ML20029C7811994-04-18018 April 1994 Application for Amend to License NPF-62,revising TS 3/4.6.6.3, SGTS & 3/4.7.2, CR Ventilation Sys to Update Rev of ASTM Std Utilized to Periodically Perform Lab Testing of Charcoal Adsorber Samples ML20029C7941994-04-18018 April 1994 Application for Amend to License NPF-62,revising TS 3/4.1.3.1,3/4.1.3.2 & 3/4.10.2 as follow-up to Util 930416 Application to Correct Noted Surveillance Number Refs to Be Consistent W/License Amend 81 Issued 930715 JSP-079-94, Application for Amend to License NPF-62,revising TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys, in Response to Inoperability of Drywell Floor Drain Sump Flow Rate Monitoring Instrumentation1994-02-25025 February 1994 Application for Amend to License NPF-62,revising TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys, in Response to Inoperability of Drywell Floor Drain Sump Flow Rate Monitoring Instrumentation U-602192, Application for Amend to License NPF-62,changing Tech Specs 3.3.2, Instrumentation-Containment & Reactor Vessel Isolation Control Sys & 3.6.5, Drywell Post-LOCA Vacuum Relief Valves1993-12-10010 December 1993 Application for Amend to License NPF-62,changing Tech Specs 3.3.2, Instrumentation-Containment & Reactor Vessel Isolation Control Sys & 3.6.5, Drywell Post-LOCA Vacuum Relief Valves JSP-505-93, Application for Amend to License NPF-62,chnaging Tech Spec 3/4.8.1.1, AC Sources-Operating, Including Requirement of DGs to Insp in Accordance W/Mfg Recommendations for Class of Standby Svc1993-11-0404 November 1993 Application for Amend to License NPF-62,chnaging Tech Spec 3/4.8.1.1, AC Sources-Operating, Including Requirement of DGs to Insp in Accordance W/Mfg Recommendations for Class of Standby Svc JSP-504-93, Application for Amend to License NPF-62,changing Tech Spec 3/4.8.2.1, DC Sources-Operating1993-11-0404 November 1993 Application for Amend to License NPF-62,changing Tech Spec 3/4.8.2.1, DC Sources-Operating 1999-08-23 |
Text
m
~
Q g;
- ?
ilhnom Power Company Chnton Power Statson .
P.O. Box 678 Chnton, IL 61727 i Tet 217 9354881 ILLIN#IS uoy,3 P9MR uv.95c 06-23 >tr June 23, 1995 1A.120 Docket No. 50-461 10CFR50.36 Document Control Desk Nuclear Regulatory Commission Washington, D.C. 20555
Subject:
Transmittal of Revision 1 to the Clinton Power Station Technical Specification Bases
Dear Sir:
Pu s - to Clinton Power Station (CPS) Technical Specification 5.5.11, "Technich. , ,ification (TS) Bases Control Program," please find enclosed replacement pages constituting Revision I to the CPS TS Bases. The changes associated with this revision were processed in accordance with CPS TS 5.5.11 which becan.e effective with Amendment No. 95 to the CPS Operating License.
In accordance with the TS Bases Control Program of CPS TS 5.5.11, Illinois Power (IP) may make changes to the CPS TS Bases without prior NRC approval provided certain criteria are met. Namely, the changes do not involve a change to the TS incorporated in the license or involve an unreviewed safety question as defined in 10 CFR 50.59. In accordance with CPS TS 5.5.11, changes to the TS Bases that are made without prior NRC approval must be submitted to the NRC on a frequency consistent with 10 CFR 50.71(e). This letter and its enclosure provide the first of these transmittals,
- covering the time period from implementation of Amendment No. 95 to the CPS Operating License on January 1,1995 until May 2,1995.
It should be noted that, in order to provide plant personnel with the most up-to-date information available in a timely manner, changes to the CPS TS Bases are distributed to controlled copies of the CPS TS in " installments." The collection of installments issued during the time period addressed by 10 CFR 50.71(e) constitutes a full revision to the CPS TS Bases. As a result, Revision I to the CPS TS Bases consists of pages annotated with Revision No. I and Revision No.1-1. Installments associated with Revision 2 to the CPS TS Bases (which will address changes made between May 2,1995 ;
'l 1
< U-602463 Page 2 and the end of the sixth refueling outage) will consist ofpages annotated with Revision No. 2-1, Revision No. 2-2, etc. Changes to the text of the CPS TS Bases are identified with revision bars. No revision bars were included for changes to format, such as moving unrevised text from one page to another.
In addition to changes that were made without prior NRC approval, this Bases revision also contains changes that were reviewed and approved by the NRC in conjunction with Amendment Nos. 97,98, and 100 to the C'" Operating License. These pages are annotated as Revision No.1 or Revision No.1-1, e applicable.
Sincerely yours, Richard F. Phares Director, Licensing DAS/csm Enclosure cc: NRC Clinton Licensing Project Manager NRC Resident Office, V-690 Regional Administrator, Region III, USNRC Illinois Department of Nuclear Safety l
!