TXX-6183, Forwards Mechanical Generic Issues Rept, Suppl a, Sys Interaction Program Corrective Action Plan & Suppl B, Fire Protection Corrective Action Plan, to Resolve Issues Raised by Design Reviews,Per Util Design Basis Program

From kanterella
(Redirected from TXX-6183)
Jump to navigation Jump to search
Forwards Mechanical Generic Issues Rept, Suppl a, Sys Interaction Program Corrective Action Plan & Suppl B, Fire Protection Corrective Action Plan, to Resolve Issues Raised by Design Reviews,Per Util Design Basis Program
ML20211G565
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 02/18/1987
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20211G570 List:
References
TXX-6183, NUDOCS 8702250433
Download: ML20211G565 (1)


Text

r 6 Log # TXX-6183 y ""=" =

File #10068 3 2 10010 clo RIELECTRIC U,INi[Na,,, February 18, 1987 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 'l

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 TRANSMITTAL 0F MECHANICAL GENERIC ISSUES REPORT REF: (a) W. G. Counsil to V. S. Noonan letter (TXX-6182 dated December 26, 1986)

/

. Gentlemen:

Enclosed are 15 copies of the following document: " Mechanical Generic Issues Report". The resolution of the items discussed in this report will be performed as part of the Design Basis Consolidation Program discussed in reference (a).

The Mechanical Generic Issues Report (GIR) has been prepared to resolve the specific design issues raised by design reviews including the third party review by TERA Corporation.

Very truly yours,

) ,

1 By: <

G. S. Keeley ' >

[

Manager,NuclearLfcensing JDS/mlh .

Enclosures  !

c- Mr. R. D. Martin, Region IV Mr. D. L. Kelley, R.I, Region IV /

Mr. H. S. Phillips, R.I., Region IV @f 8702250433 B70218 PDR ADOCK 05000M W l[

^ PDR

  • N) North Olise Street I. 11. 8 1 Dallas, lexas 75201