TXX-4048, Responds to NRC Concerns Re High/Moderate Energy Pipe Break Analysis.Moderate Energy Break of Safeguards Bldg Auxiliary Feedwater Pipe Supplied by Condensate Storage Tank Found to Be Nonlimiting

From kanterella
(Redirected from TXX-4048)
Jump to navigation Jump to search
Responds to NRC Concerns Re High/Moderate Energy Pipe Break Analysis.Moderate Energy Break of Safeguards Bldg Auxiliary Feedwater Pipe Supplied by Condensate Storage Tank Found to Be Nonlimiting
ML20080G414
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 09/13/1983
From: Schmidt H
TEXAS UTILITIES SERVICES, INC.
To: Youngblood B
Office of Nuclear Reactor Regulation
References
TXX-4048, NUDOCS 8309200265
Download: ML20080G414 (2)


Text

.

TEXAS UTILITIES SERVICES INC.

Log # TXX-4048 anni onm mwen muw reun mo' '"

File # 903.6 September 13, 1983 Mr. B. J. Youngblood U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION DOCKET N05. 50-445 AND 50-446 RESPONSE TO HIGH/ MODERATE ENERGY PIPE BREAK ANALYSIS CONCERNS

Dear Mr. Youngblood:

In response to NRC concerns documented in Texas Utilities letters TXX-3336 dated June 16, 1981 and TXX-3351 dated June 24, 1981 we provide the following:

1.

The moderate energy break of the Safeguards Building auxiliary feedwater pipe supplied by the condensate storage tank was analyzed and found to be non-limiting. Flooding from a crack in the safety injection line was found to be more severe.

The results of the limiting flooding analysis have been used in the design of protection for essential equipment in the affected area.

These protective measures consist of installation of physical barriers and/or relocation of essential equipment.

2.

The steam generator PORV controls (including pressure transducers) are designed for a pipe crack environment. The environmental qualification of the equipment is currently in progress.

See CPSES/EQR Table 5-1 for qualification parameters.

3.

Steam / feed line break (Super Pipe) in the break exclusion zone outside of containment is discussed in the response to 0010.20.

Equipment qualification parameters are presented in CPSES/EQR Tables 5-1 and 5-2.

The environmental qualification of affected equipment is currently in progress.

4.

A discussion of the high energy pipe break analysis is presented in FSAR Section 3.6B.

Table 3.68-1 presents a list of pipes where breaks are postulated and includes line fluid parameters t~d type of jet emanating from the break. Table 3.11B presents a list of all Class 1E equipment affected by the break and includes the postulated environment and the equipment qualification parameters.

$0t> f 8309200265 830913 llo PDR ADOCK 05000445

2 5.

A discussion of the jet impingement analysis is presented in FSAR Section 3.68.2.5.2.

6.

Analyses of moderate energy and high energy pipe breaks include the affects of flooding on redundant essential equipment.

Specifically, flooding between adjacent compartments as a result of floor drain failure is considered, including areas where floor drains are connected to a single header such as the AFW pump rooms and the charging pump rooms.

Should you have additional questions, please contact this office.

Sincerely,

/

H. C. Schmidt BSD/grr

.,. ~ -

.-.