TXX-3088, Forwards Interim Deficiency Rept Re Violation of Piping Min Wall Thickness.Supporting Documentation Is Available at Job Site for NRC Inspector Review
| ML19305B047 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 01/14/1980 |
| From: | Gary R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Seidle W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| Shared Package | |
| ML19305B048 | List: |
| References | |
| TXX-3088, NUDOCS 8003190070 | |
| Download: ML19305B047 (1) | |
Text
_
l 7.zc TEXAS UTILITIES GENERATING COMPANY 2003 BRYAN TOWER. DALLA $6. TEXAS 76201
...ei.t!.^.".I....-
January 14, 1980
^ ~ " " ' " ' " ' ' ' ' "
TXX-3088 Mr. W. C.-Seidle, Chief Reactor Construction & Engineering Support Branch U. S. Nyclear Regulatory Comission Office of Inspection & Enforcement 611 Ryan Plaza Dr., Suite 1000 Docket Nos. 50-445 Arlington, Texas 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION 1981-83 2300 MW INSTALLATION PIPING MINIMUM WALL FILE N0:
10110
Dear Mr. Seidle:
In accordance with 10 CFR 50.55(e) we are submitting the attached report concerning a violation of piping minimum wall thickness.
We previously made a verbal report to Mr. R. G. Taylor on May 22, 1979 and submitted an interim report logged TXX-3038 dated September 11, 1979.
Supporting documentation is available at the job-site for your inspector's review.
If we can provide any additional information, please advise.
Very truly yours,
/
R /J. -Gary Attachment RJG:df cc:
NRC Region IV (0 + 1 copy)
Director, Inspection & Enforcement (15 copies) c/o Distribution Services Branch, DDC, ADM.
U. S. Nuclear Regulatory Commission Washington, D. C.
20555 8003190 Q90 es