MONTHYEARAECM-87-0103, Requests Relief from Installing Addl motor-operated Valves to Assure Containment Leak Integrity in Various Small Instrument Relief Lines,As Required in NRC . Justification Encl.Requests NRC Review.Fee Paid1987-07-0202 July 1987
[table view]Requests Relief from Installing Addl motor-operated Valves to Assure Containment Leak Integrity in Various Small Instrument Relief Lines,As Required in NRC . Justification Encl.Requests NRC Review.Fee Paid ML20234A9471987-09-0404 September 1987 Safety Evaluation Re Util 870702 Submittal Re Containment Isolation for Various Instrument Lines.Util Proposed Alternate Basis to Meet GDC 55 to 10CFR50 App a Acceptable ML20234A9051987-09-0404 September 1987 Forwards Safety Evaluation of Util 870702 Submittal Re Small Diameter Pressure Instrument Lines Penetrating Containment & Effect on Containment Integrity.Util Proposal to Add Manual Valves Acceptable.Description of Final Design Requested ML20196H2931988-03-0707 March 1988 Discusses NRC Reviews Re Providing Results of Analysis.Nrc Review Concludes That Plant Instruments Lines Meet Nine Criteria in Ansi/Ans Std 56.2 - 1984 for Closed Sys Outside Containment & Acceptable 1987-09-04 |