TAC:56814
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Initiation
Questions Answers Results Other: B10927, Provides Summary of Reevaluations of LOCA Based on Identification of Several Assemblies Containing Leaking Fuel Pins & fuel-related Damage Which Necessitated Rev to Cycle 6 Core Loading Pattern, B11486, Forwards Small Break Loca/Eccs Performance Analysis W/Axial Shape Index of -0.10. Encl Analysis Amends Loca/Eccs Analysis Provided in Per 10CFR50,App K-II.1.b. Previous Reviews Re Effects of Reloads Remain Valid, B11561, Forwards Reload Safety Analysis in Support of Cycle 7 Reload.Core Reload Will Not Adversely Affect Plant Safety, B11568, Forwards Results of Core Barrel Insp Performed During Cycle 7 Refueling outage.Through-wall Cracks at Thermal Shield Support Lugs 4 & 5 Not Propagated, B11570, Highlights Recent Major Milestones in Fuel Performance Program.Three Investigations Conducted During Last Half of Cycle 6 Operation & Weld Defects Probed.No Significant mfg- Related Failure Mechanisms Noted, ML20107A012, ML20115J066, ML20126C726, ML20126J181, ML20128D276 | |
From | |
MONTHYEARB10927, Provides Summary of Reevaluations of LOCA Based on Identification of Several Assemblies Containing Leaking Fuel Pins & fuel-related Damage Which Necessitated Rev to Cycle 6 Core Loading Pattern1983-11-0202 November 1983
[table view]Provides Summary of Reevaluations of LOCA Based on Identification of Several Assemblies Containing Leaking Fuel Pins & fuel-related Damage Which Necessitated Rev to Cycle 6 Core Loading Pattern ML20107A0121985-02-0606 February 1985 Proposed Tech Spec Changes for Preliminary Reload Safety Analysis Re Cycle 7 Refueling B11437, Application for Amend to License DPR-65,consisting of Proposed Revs to Tech Specs for Preliminary Reload Safety Analysis Re Cycle 7 Refueling1985-02-0606 February 1985 Application for Amend to License DPR-65,consisting of Proposed Revs to Tech Specs for Preliminary Reload Safety Analysis Re Cycle 7 Refueling B11486, Forwards Small Break Loca/Eccs Performance Analysis W/Axial Shape Index of -0.10. Encl Analysis Amends Loca/Eccs Analysis Provided in Per 10CFR50,App K-II.1.b. Previous Reviews Re Effects of Reloads Remain Valid1985-04-11011 April 1985 Forwards Small Break Loca/Eccs Performance Analysis W/Axial Shape Index of -0.10. Encl Analysis Amends Loca/Eccs Analysis Provided in Per 10CFR50,App K-II.1.b. Previous Reviews Re Effects of Reloads Remain Valid ML20115J0661985-04-30030 April 1985 Small Break Loca/Eccs Performance Analysis W/Axial Shape Index of -0.10 B11561, Forwards Reload Safety Analysis in Support of Cycle 7 Reload.Core Reload Will Not Adversely Affect Plant Safety1985-06-0505 June 1985 Forwards Reload Safety Analysis in Support of Cycle 7 Reload.Core Reload Will Not Adversely Affect Plant Safety ML20126C7261985-06-11011 June 1985 Proposed Revs to Tech Spec Sections 3.2.1,Page 3/4 2-1 & 3.2.2.2,Page 3/4 2-6 Re Cycle 7 Reload B11570, Highlights Recent Major Milestones in Fuel Performance Program.Three Investigations Conducted During Last Half of Cycle 6 Operation & Weld Defects Probed.No Significant mfg- Related Failure Mechanisms Noted1985-06-11011 June 1985 Highlights Recent Major Milestones in Fuel Performance Program.Three Investigations Conducted During Last Half of Cycle 6 Operation & Weld Defects Probed.No Significant mfg- Related Failure Mechanisms Noted B11568, Forwards Results of Core Barrel Insp Performed During Cycle 7 Refueling outage.Through-wall Cracks at Thermal Shield Support Lugs 4 & 5 Not Propagated1985-06-11011 June 1985 Forwards Results of Core Barrel Insp Performed During Cycle 7 Refueling outage.Through-wall Cracks at Thermal Shield Support Lugs 4 & 5 Not Propagated B11569, Application for Amend to License DPR-65,revising Tech Spec Sections 3.2.1,Page 3/4 2-1 & 3.2.2.2,Page 3/4 2-6 Re Cycle 7 Reload,Based on Discussions W/Nrc1985-06-11011 June 1985 Application for Amend to License DPR-65,revising Tech Spec Sections 3.2.1,Page 3/4 2-1 & 3.2.2.2,Page 3/4 2-6 Re Cycle 7 Reload,Based on Discussions W/Nrc ML20128D2851985-06-19019 June 1985 Safety Evaluation Supporting Amend 99 to License DPR-65 ML20128D2761985-06-19019 June 1985 Amend 99 to License DPR-65,revising Tech Specs Re Allowable Region of Operation When Core Power Distribution Monitored by ex-core Detector Monitoring Sys ML20128D2631985-06-19019 June 1985 Forwards Amend 99 to License DPR-65 & Safety Evaluation. Amend Revises Tech Specs to Modify Allowable Region of Operation When Core Power Distribution Monitored by ex-core Detector Monitoring Sys.Revs Reflect Changes in Cycle 7 B11590, Forwards Supplemental Info Describing Zone Enriched Assembly Configuration Implemented in Feed Fuel Regions for Cycle 71985-06-25025 June 1985 Forwards Supplemental Info Describing Zone Enriched Assembly Configuration Implemented in Feed Fuel Regions for Cycle 7 ML20126J1811985-06-30030 June 1985 Cycle 7 Final Reload Safety Analysis 1985-06-11 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:56814&oldid=3461674"